CorrugateCOMMERCIAL HORIZONTAL CLADDING
0800 ROOFNZ (0800 766 369)www.metalcraftroofing.co.nz
Architectural / Specification EnquiriesPh: 09 274 0408
Mobile: 027 603 1096Email: [email protected]
00 / 23 COVER SHEET01 / 23 PARAPET AND BALUSTRADE CAPPING02 / 23 SOFFIT03 / 23 FLUSH WINDOW HEAD04 / 23 FLUSH WINDOW SILL05 / 23 FLUSH WINDOW JAMB06 / 23 RECESSED WINDOW HEAD07 / 23 RECESSED WINDOW SILL08 / 23 RECESSED WINDOW JAMB09 / 23 BUTT WINDOW HEAD10 / 23 BUTT WINDOW SILL11 / 23 BUTT WINDOW JAMB12 / 23 METERBOX HEAD13 / 23 METERBOX SILL14 / 23 METERBOX JAMB15 / 23 INTERNAL CORNER16 / 23 EXTERNAL CORNER17 / 23 INTERNAL CORNER BOX TYPE18 / 23 EXTERNAL CORNER BOX TYPE19 / 23 SOAKER FLASHING20 / 23 VERTICAL BUTT JOINT21 / 23 BOTTOM OF CLADDING (FLUSH)22 / 23 BOTTOM OF CLADDING (RECESSED)23 / 23 3D WINDOW FLASHINGS
DETAIL LIST
BUILDING PAPER SHOWN DASHED
PRE-FINISHED SELF DRILLING / TAPPINGSCREW WITH RUBBER WASHER
METALCRAFT CORRUGATEHORIZONTAL WALL CLADDING
METALCRAFT MSS PURLINBY ENGINEER
MIN
. 5.00°
20mm CAVITY
PRE-FINISHED POP RIVET BEDDED INSILICONE OR PRE-FINISHED 8gWAFER-TEK SCREW
CLE
ARAN
CE
25m
m
PRE-FINISHED PARAPET CAP FLASHINGNO FIXINGS ON TOP OF FLASHING
CONTINUOUS H3.1 TIMBER PACKING
BUILDING PAPER TO PROVIDESEPARATION OF METAL CAPPING ANDCLADDING WITH TIMBER SHOWN DASHED
CLE
ARAN
CE
25m
m
BIRDS BEAK EDGE FORDECK SIDE OF CAPPING
5 GAP
20
15
MIN
. 2 C
OR
RU
GAT
ION
S
MIN
. 2 C
OR
RU
GAT
ION
S
ScaleDate Sheet
Corrugate
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.
COMMERCIAL HORIZONTAL CLADDING
CHCG
- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.
1 : 2 01 / 23
PARAPET AND BALUSTRADE CAPPING
2014
BUILDING PAPER OVERFLASHING SHOWN DASHED
INTERNAL WALL LINING
METALCRAFT MSS PURLINBY ENGINEER
METALCRAFT CORRUGATEHORIZONTAL WALL CLADDING
PRE-FINISHED SOFFIT FLASHING BARGE BOARD
SOFFIT LINING
METALCRAFTMSS PURLIN BYENGINEER
PRE-FINISHED SELFDRILLING/TAPPING SCREWWITH RUBBER WASHER
INTERNAL CEILING LINING
CO
VER
CLA
DD
ING
40 m
m (M
IN. 3
5mm
)
PRE-FINISHED FLAT HEAD WAFER-TEKSCREW FOR FLASHING
BUILDING PAPER TO PROVIDESEPARATION OF FLASHING ANDCLADDING WITH TIMBER SHOWNDASHED20mm CAVITY
5mm GAP MIN. 50mm
PRE-FINISHED POP RIVET BEDDED INSILICONE OR PRE-FINISHED 8gWAFER-TEK SCREW
ScaleDate Sheet
Corrugate
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.
COMMERCIAL HORIZONTAL CLADDING
CHCG
- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.
1 : 2 02 / 23
SOFFIT
2014
BUILDING PAPER DRESSED INTOOPENING WITH FLEXIBLE FLASHINGTAPE INSTALLED OVER WRAP TOCORNERS AT HEAD
TEMPORARY PACKER IF REQUIRED,REMOVED AFTER FIXING
EXTRA BUILDING PAPER OVER WINDOWHEAD FLASHING SHOWN DASHED
INTERNAL WALL LINING
METALCRAFT MSS PURLIN BY ENGINEER
METALCRAFT CORRUGATE HORIZONTALWALL CLADDING
PRE-FINISHED WINDOW HEADFLASHING WITH 15° FALL
PRE-FINISHED SELF DRILLING/TAPPINGSCREW WITH RUBBER WASHER
DOUBLE GLAZING WINDOW JOINERY
AIRSEAL ON BACKING ROD TO RUNCONTINUOUSLY AROUND HEAD, SILLAND JAMB
WINDOW HEAD LINER
LINE OF WINDOW JAMBLINER BEHIND
STOPENDS TO HEAD FLASHING
LINE OF JAMB FLASHING BEHIND
METALCRAFT MSS PURLIN BYENGINEER
5mm
GAP
PRE-FINISHED FLAT HEAD WAFER-TEK SCREW FOR FLASHING
PVC CAVITY CLOSER
BUILDING PAPER TO PROVIDESEPARATION OF FLASHING ANDCLADDING WITH TIMBER SHOWN DASHED
MIN
. 10m
m C
OVE
RDR
IP E
DG
E TO
CLA
DD
I NG
MIN
. 15m
m G
AP
MIN
. 75m
m W
ITH
OU
T H
EM
ED
GE
MIN
. 50m
m C
OVE
R
SU
GG
EST
MIN
. 50m
m
DIM
ENS
ION
TO
SU
IT
COMPRESSIBLE FOAM SEAL TO FILLOVERLAP OF FLASHING
ScaleDate Sheet
Corrugate
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.
COMMERCIAL HORIZONTAL CLADDING
CHCG
- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.
1 : 2 03 / 23
FLUSH WINDOW HEAD
2014
METALCRAFT CORRUGATEHORIZONTAL WALL CLADDING
BUILDING PAPER SHOWN DASHED
DOUBLE GLAZING WINDOW JOINERY
LINE OF WINDOW JAMBLINER BEHIND
WINDOW SILL LINER
MIN. 8mm PACKER
AIRSEAL ON BACKING ROD TO RUNCONTINUOUSLY AROUND HEAD,SILL AND JAMB
WINDOW SILL SUPPORT BAR
METALCRAFT MSS PURLIN BY ENGINEER
INTERNAL WALL LINING
STOPENDS TO SILL FLASHING
LINE OF JAMB FLASHING BEHIND
BUILDING PAPER TO PROVIDESEPARATION OF FLASHING ANDCLADDING WITH TIMBER SHOWN DASHED
FLEXIBLE FLASHING TAPE OVER BUILDINGPAPER FOR FULL WIDTH/DEPTH SILL
PRE-FINISHED WINDOW SILLFLASHING
5mm GAP MIN
. 8m
m C
OV
ER
20mm CAVITY
CO
VER
CLA
DD
ING
50m
m(M
IN. 3
5mm
)
PRE-FINISHED SELF DRILLING/TAPPINGSCREW WITH RUBBER WASHER
PRE-FINISHED SECONDARY FLASHING
PRE-FINISHED POP RIVET BEDDED INSILICONE OR PRE-FINISHED 8g WAFER-TEK SCREW
PRE-FINISHED FLAT HEAD WAFER-TEK SCREW FOR FLASHING
ScaleDate Sheet
Corrugate
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.
COMMERCIAL HORIZONTAL CLADDING
CHCG
- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.
1 : 2 04 / 23
FLUSH WINDOW SILL
2014
METALCRAFT CORRUGATEHORIZONTAL WALL CLADDING
BUILDING PAPER SHOWN DASHED
DOUBLE GLAZING WINDOW JOINERY
LINE OF WINDOW SILL LINER BELOW
WINDOW JAMB LINER
TIMBER PACKER
AIRSEAL ON BACKING ROD TO RUNCONTINUOUSLY AROUND HEAD,SILL AND JAMB
20mm JAMB BATTEN
INTERNAL WALL LINING
LINE OF SILL FLASHING BELOW
PRE-FINISHED SELF DRILLING/TAPPINGSCREW WITH RUBBER WASHER
METALCRAFT MSS PURLIN BYENGINEER
LINE OF SILL FLASHING BELOW
PRE-FINISHED WINDOW JAMBFLASHING
PRE-FINISHED SECONDARYFLASHING
FLEXIBLE FLASHING TAPE OVERBUILDING PAPER FOR FULLWIDTH/DEPTH SILL
MIN. 10mm COVER
20mm CAVITY
BUILDING PAPER TO PROVIDESEPARATION OF FLASHINGAND CLADDING WITH TIMBERSHOWN DASHED
5mm
GAP
CONTINUOUS COMPRESSIBLEFOAM SEAL. REFER TO MRM CODEOF PRACTICE VERSION 2.2 /2012FOR REQUIRMENT.
SUGGEST MIN. 50mm
DIMENSION TO SUIT
PRE-FINISHED FLAT HEAD WAFER-TEK SCREW FOR FLASHING
LINE OF HEAD FLASHING ABOVE
PRE-FINISHED POP RIVET BEDDEDIN SILICONE OR PRE-FINISHED 8gWAFER-TEK SCREW
COMPRESSIBLE FOAM SEAL TO FILLOVERLAP OF FLASHING
LINE OF HEAD FLASHING ABOVE
ScaleDate Sheet
Corrugate
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.
COMMERCIAL HORIZONTAL CLADDING
CHCG
- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.
1 : 2 05 / 23
FLUSH WINDOW JAMB
2014
BUILDING PAPER DRESSED INTOOPENING WITH FLEXIBLE FLASHINGTAPE INSTALLED OVER WRAP TOCORNERS AT HEAD
TEMPORARY PACKER IF REQUIRED,REMOVED AFTER FIXING
EXTRA BUILDING PAPER OVER WINDOWHEAD FLASHING SHOWN DASHED
INTERNAL WALL LINING METALCRAFT CORRUGATE HORIZONTALWALL CLADDING
PRE-FINISHED WINDOW HEADFLASHING WITH 15° FALL
PRE-FINISHED FLAT HEAD WAFER-TEKSCREW FOR FLASHING
DOUBLE GLAZING WINDOW JOINERY
AIRSEAL ON BACKING ROD TO RUNCONTINUOUSLY AROUND HEAD,SILL AND JAMB
WINDOW HEAD LINER
LINE OF WINDOW JAMBLINER BEHIND
STOPENDS TO HEAD FLASHING
LINE OF JAMB FLASHING BEHIND
PRE-FINISHED SELF DRILLING/TAPPINGSCREW WITH RUBBER WASHER
DR
IP E
DG
E TO
CLA
DD
I NG
MIN
. 15m
m G
AP
MIN
. 10m
m C
OVE
R
5mm
GAP M
IN.7
5mm
WIT
HO
UT
HE
M E
DG
E
MIN
. 50m
m C
OVE
R
BUILDING PAPER TO PROVIDESEPARATION OF FLASHING ANDCLADDING WITH TIMBER SHOWN DASHED
SU
GG
EST
MIN
.50m
m
DIM
ENS
ION
TO
SU
IT
PVC CAVITY CLOSER
ScaleDate Sheet
Corrugate
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.
COMMERCIAL HORIZONTAL CLADDING
CHCG
- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.
1 : 2 06 / 23
RECESSED WINDOW HEAD
2014
METALCRAFT CORRUGATE HORIZONTALWALL CLADDING
BUILDING PAPER SHOWN DASHED
PRE-FINISHED WINDOW SILL FLASHING
LINE OF WINDOW JAMBLINER BEHIND
WINDOW SILL LINER
MIN. 8mm PACKER
AIRSEAL ON BACKING ROD TO RUNCONTINUOUSLY AROUND HEAD,SILL AND JAMB
WINDOW SILL SUPPORT BAR
INTERNAL WALL LINING
STOPENDS TO SILL FLASHING
LINE OF JAMB FLASHING BEHIND
PRE-FINISHED SELF DRILLING/TAPPINGSCREW WITH RUBBER WASHER
20mm CAVITY
FLEXIBLE FLASHING TAPE OVERBUILDING PAPER FOR FULLWIDTH/DEPTH SILL
DOUBLE GLAZING WINDOW JOINERY
METALCRAFT MSS PURLIN BY ENGINEER
5mm
GAP
MIN
. 8m
m C
OV
ER
PRE-FINISHED SECONDARY FLASHING
BUILDING PAPER DRESSED INTOOPENING WITH FLEXIBLE FLASHINGTAPE INSTALLED OVER WRAP TOCORNERS AT SILL
CLA
DD
ING
CO
VER
50m
m(M
IN. 3
5mm
)
BUILDING PAPER TO PROVIDESEPARATION OF FLASHING ANDCLADDING WITH TIMBER SHOWN DASHED
PRE-FINISHED FLAT HEAD WAFER-TEKSCREW FOR FLASHING
PRE-FINISHED POP RIVET BEDDED INSILICONE OR PRE-FINISHED 8gWAFER-TEK SCREW
ScaleDate Sheet
Corrugate
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.
COMMERCIAL HORIZONTAL CLADDING
CHCG
- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.
1 : 2 07 / 23
RECESSED WINDOW SILL
2014
PRE-FINISHED POP RIVET BEDDED IN SILICONEOR PRE-FINISHED 8g WAFER-TEK SCREW DOUBLE GLAZING WINDOW JOINERY
LINE OF HEAD FLASHING ABOVE
PRE-FINISHED SELFDRILLING/TAPPING SCREWWITH RUBBER WASHER
PRE-FINISHED SECONDARYFLASHING
20mm CAVITY
INTERNAL WALL LINING
BUILDING PAPER SHOWN DASHED
LINE OF WINDOW SILL LINER BELOW
WINDOW JAMB LINER
TIMBER PACKER
AIRSEAL ON BACKING ROD TO RUNCONTINUOUSLY AROUND HEAD,SILL AND JAMB
20mm JAMB BATTEN
FLEXIBLE FLASHING TAPE OVERBUILDING PAPER FOR FULLWIDTH/DEPTH SILL
METALCRAFT MSS PURLIN BYENGINEER
5mm
GAP
5mm GAP
MIN. 10mm COVERMETALCRAFT CORRUGATEHORIZONTAL WALL CLADDING
BUILDING PAPER TO PROVIDESEPARATION OF FLASHING ANDCLADDING WITH TIMBER SHOWNDASHED
CONTINUOUS COMPRESSIBLE FOAMSEAL. REFER TO MRM CODE OFPRACTICE VERSION 2.2 /2012 FORREQUIRMENT.
SUGGEST MIN. 50mm
DIMENSION TO SUIT
LINE OF SILL FLASHING BELOW
LINE OF HEAD FLASHING ABOVE
PRE-FINISHED FLAT HEAD WAFER-TEK SCREW FOR FLASHING
PRE-FINISHED WINDOW JAMBFLASHING
ScaleDate Sheet
Corrugate
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.
COMMERCIAL HORIZONTAL CLADDING
CHCG
- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.
1 : 2 08 / 23
RECESSED WINDOW JAMB
2014
TEMPORARY PACKER IF REQUIRED,REMOVED AFTER FIXING
20mm CAVITY
BUILDING PAPER TO PROVIDESEPARATION OF FLASHING ANDCLADDING WITH TIMBER SHOWN DASHED
PRE-FINISHED WINDOW HEADFLASHING WITH 15° FALL
PRE-FINISHED FLAT HEAD WAFER-TEKSCREW FOR FLASHING
DOUBLE GLAZING WINDOW JOINERYWINDOW HEAD LINER
LINE OF WINDOW JAMB LINERBEHIND
STOPENDS TO HEAD FLASHING
LINE OF JAME FLASHING BEHIND
BUILDING PAPER DRESSED INTOOPENING WITH FLEXIBLE FLASHINGTAPE INSTALLED OVER WRAP TOCORNERS AT HEAD
INTERNAL WALL LINING
AIRSEAL ON BACKING ROD TO RUNCONTINUOUSLY AROUND HEAD,SILL AND JAMB
METALCRAFT MSS PURLIN BY ENGINEER
EXTRA BUILDING PAPER OVER WINDOWHEAD FLASHING SHOWN DASHED
MIN
.75m
m W
ITH
OU
T H
EM
ED
GE
MIN
. 50m
m C
OVE
R
DR
IP E
DG
E TO
CLA
DD
ING
MIN
. 15m
m G
AP
METALCRAFT CORRUGATE HORIZONTALWALL CLADDING
5mm
GAP
MIN
.10m
m C
OVE
R
SU
GG
EST
MIN
. 50m
m
DIM
ENS
ION
TO
SU
IT
PVC CAVITY CLOSER
PRE-FINISHED SELF DRILLING/TAPPINGSCREW WITH RUBBER WASHER FORFLASHING
ScaleDate Sheet
Corrugate
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.
COMMERCIAL HORIZONTAL CLADDING
CHCG
- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.
1 : 2 09 / 23
BUTT WINDOW HEAD
2014
PRE-FINISHED SECONDARY FLASHING
STOPENDS TO SILL FLASHING
LINE OF JAMB FLASHING BEHIND
DOUBLE GLAZING WINDOW JOINERY
LINE OF WINDOW JAMBLINER BEHIND
WINDOW SILL LINER
MIN. 8mm PACKER
AIRSEAL ON BACKING ROD TO RUNCONTINUOUSLY AROUND HEAD,SILL AND JAMB
METALCRAFT CORRUGATE HORIZONTALWALL CLADDING
BUILDING PAPER SHOWN DASHED
20mm CAVITY
INTERNAL WALL LINING
PRE-FINISHED SELF DRILLING/TAPPINGSCREW WITH RUBBER WASHER
METALCRAFT MSS PURLIN BY ENGINEER 5mm
GAP
MIN
. 8m
m C
OV
ER
BUILDING PAPER TO PROVIDESEPARATION OF FLASHING ANDCLADDING WITH TIMBER SHOWNDASHED
PRE-FINISHED POP RIVET BEDDED INSILICONE OR PRE-FINISHED 8g WAFER-TEK SCREW
WINDOW SILL SUPPORT BAR
PRE-FINISHED WINDOW SILL FLASHING
SU
GG
EST
MIN
.50m
m
DIM
ENS
ION
TO
SU
IT
FLEXIBLE FLASHING TAPE OVERBUILDING PAPER FOR FULLWIDTH/DEPTH SILL
PRE-FINISHED FLAT HEAD WAFER-TEKSCREW FOR FLASHING
5mm GAP
ScaleDate Sheet
Corrugate
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.
COMMERCIAL HORIZONTAL CLADDING
CHCG
- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.
1 : 2 10 / 23
BUTT WINDOW SILL
2014
PRE-FINISHED SELFDRILLING/TAPPING SCREWWITH RUBBER WASHER
DOUBLE GLAZING WINDOW JOINERY
LINE OF SILL FLASHING BELOWCONTINUOUS COMPRESSIBLEFOAM SEAL. REFER TO MRM CODEOF PRACTICE VERSION 2.2 /2012FOR REQUIRMENT.
METALCRAFT CORRUGATEHORIZONTAL WALL CLADDING
INTERNAL WALL LINING
BUILDING PAPER SHOWN DASHED
LINE OF WINDOW SILL LINER BELOW
WINDOW JAMB LINER
TIMBER PACKER
AIRSEAL ON BACKING ROD TO RUNCONTINUOUSLY AROUND HEAD,SILL AND JAMB
20mm JAMB BATTEN
FLEXIBLE FLASHING TAPE OVERBUILDING PAPER FOR FULLWIDTH/DEPTH SILL
METALCRAFT MSS PURLIN BYENGINEER
5mm GAP 5mm GAP
MIN. 50mm
MIN. 10mm COVER
5mm
GAP
BUILDING PAPER TO PROVIDESEPARATION OF FLASHING ANDCLADDING WITH TIMBER SHOWNDASHED
PRE-FINISHED WINDOW JAMBFLASHING
SUGGEST MIN. 50mm
DIMENSION TO SUIT
LINE OF HEAD FLASHING ABOVE
PRE-FINISHED FLAT HEAD WAFER-TEK SCREW FOR FLASHING
LINE OF HEAD FLASHING ABOVE
ScaleDate Sheet
Corrugate
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.
COMMERCIAL HORIZONTAL CLADDING
CHCG
- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.
1 : 2 11 / 23
BUTT WINDOW JAMB
2014
BUILDING PAPER DRESSED INTOOPENING WITH FLEXIBLE FLASHINGTAPE INSTALLED OVER WRAP TOCORNERS AT HEAD
TEMPORARY PACKER IF REQUIRED,REMOVED AFTER FIXING
EXTRA BUILDING PAPER OVER WINDOWHEAD FLASHING SHOWN DASHED
METALCRAFT CORRUGATE HORIZONTALWALL CLADDING
PRE-FINISHED HEAD FLASHINGWITH 15° FALL
PRE-FINISHED SELF DRILLING/TAPPINGSCREW WITH RUBBER WASHER
AIRSEAL ON BACKING ROD TO RUNCONTINUOUSLY AROUND HEAD, SILLAND JAMB
METER BOX
STOPENDS TO HEAD FLASHING
LINE OF JAMB FLASHING BEHIND
PRE-FINISHED FLASHING
METAL ANGLE TO BE CONTINUOUSAROUND METER BOX.
INTERNAL WALL LINING
METALCRAFT MSS PURLIN BY ENGINEER
DR
IP E
DG
E TO
CLA
DD
ING
MIN
. 15m
m G
AP
5mm
GAP M
IN. 7
5mm
WIT
HO
UT
HE
M E
DG
E
MIN
. 50m
m C
OVE
R
PRE-FINISHED 'U' BRACKET FIXED TOMETERBOX BEFORE INSTALLATION
BUILDING PAPER TO PROVIDESEPARATION OF FLASHING ANDCLADDING WITH TIMBER SHOWN DASHED
PVC CAVITY CLOSER
PRE-FINISHED FLAT HEAD WAFER-TEKSCREW FOR FLASHING
ScaleDate Sheet
Corrugate
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.
COMMERCIAL HORIZONTAL CLADDING
CHCG
- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.
1 : 2 12 / 23
METERBOX HEAD
2014
METALCRAFT CORRUGATE HORIZONTALWALL CLADDING
BUILDING PAPER SHOWN DASHED
METER BOX
INTERNAL WALL LINING
MIN. 8mm PACKER
AIRSEAL ON BACKING ROD TO RUNCONTINUOUSLY AROUND HEAD,SILL AND JAMB
METALCRAFT MSS PURLIN BYENGINEER
INTERNAL WALL LINING
LINE OF JAMB FLASHING BEHIND
PRE-FINISHED SELF DRILLING/TAPPINGSCREW WITH RUBBER WASHER FORWINDOW SUPPORT BAR
20mm CAVITY
FLEXIBLE FLASHING TAPE OVERBUILDING PAPER FOR FULLWIDTH/DEPTH SILL
METAL ANGLE TO BE CONTINUOUSAROUND METER BOX.
PRE-FINISHED FLASHING
BUILDING PAPER TO PROVIDESEPARATION OF FLASHING ANDCLADDING WITH TIMBER SHOWNDASHED
PRE-FINISHED POP RIVET BEDDED INSILICONE OR PRE-FINISHED 8g WAFER-TEK SCREW
STOPENDS TO SILL FLASHING
CO
VER
CLA
DD
ING
50m
m(M
IN. 3
5mm
)
PRE-FINISHED SECONDARYFLASHING
PRE-FINISHED FLAT HEAD WAFER-TEK SCREW FOR FLASHING
ScaleDate Sheet
Corrugate
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.
COMMERCIAL HORIZONTAL CLADDING
CHCG
- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.
1 : 2 13 / 23
METERBOX SILL
2014
BUILDING PAPER SHOWN DASHED METER BOX
TIMBER PACKER
20mm JAMB BATTEN
PRE-FINISHED WINDOW JAMBFLASHING FIXED TO METERBOXBEFORE INSTALLATION
PRE-FINISHED SELF DRILLING/TAPPINGSCREW WITH RUBBER WASHER
FLEXIBLE FLASHING TAPE OVER BUILDINGPAPER FOR FULL WIDTH/DEPTH SILL
LINE OF HEAD FLASHING ABOVE
20mm CAVITY
AIRSEAL ON BACKING ROD TO RUNCONTINUOUSLY AROUND HEAD,SILL AND JAMB
METAL ANGLE TO BE CONTINUOUSAROUND METER BOX.
INTERNAL WALL LININGMETALCRAFT MSS PURLIN BY ENGINEER
AIRSEAL ON BACKING ROD TO RUNCONTINUOUSLY AROUND HEAD,SILL AND JAMB
CONTINUOUS COMPRESSIBLE FOAMSEAL. REFER TO MRM CODE OFPRACTICE VERSION 2.2 /2012 FORREQUIRMENT.
METALCRAFT CORRUGATEHORIZONTAL WALL CLADDING
BUILDING PAPER TO PROVIDESEPARATION OF FLASHING ANDCLADDING WITH TIMBER SHOWNDASHED
PRE-FINISHED POP RIVET BEDDED INSILICONE OR PRE-FINISHED 8g WAFER-TEKSCREW
SUGGEST MIN. 50mm
DIMENSION TO SUIT
LINE OF SILL FLASHING BELOW
PRE-FINISHED FLAT HEAD WAFER-TEKSCREW FOR FLASHING
ScaleDate Sheet
Corrugate
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.
COMMERCIAL HORIZONTAL CLADDING
CHCG
- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.
1 : 2 14 / 23
METERBOX JAMB
2014
METALCRAFT CORRUGATEHORIZONTAL WALL CLADDING
20mm CAVITYPRE-FINISHED POP RIVETBEDDED IN SILICONE ORPRE-FINISHED 8g WAFER-TEK SCREW
INTERNAL WALL LINING
PRE-FINISHED FIXING BRACKETWITH PRE-FINISHED SELFDRILLING/TAPPING SCREW WITHRUBBER WASHER
PRE-FINISHED FLAT HEAD WAFER-TEK SCREW FOR FLASHING
BUILDING PAPER SHOWNDASHED
STRUCTURAL COLUMN BYENGINEER
METALCRAFT MSS PURLIN BYENGINEER
SU
GG
EST
MIN
. 75m
m
DIM
ENS
ION
TO
SU
IT
SUGGEST MIN. 75mm
DIMENSION TO SUIT
CONTINUOUS COMPRESSIBLEFOAM SEAL. REFER TO MRMCODE OF PRACTICE VERSION2.2 /2012 FOR REQUIRMENT.
BUILDING PAPER TO PROVIDESEPARATION OF FLASHING ANDCLADDING WITH TIMBER SHOWNDASHED
PRE-FINISHED INTERNALCORNER FLASHING
PRE-FINISHED SECONDARYFLASHING
ScaleDate Sheet
Corrugate
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.
COMMERCIAL HORIZONTAL CLADDING
CHCG
- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.
1 : 2 15 / 23
INTERNAL CORNER
2014
METALCRAFT MSS PURLIN BYENGINEER
20mm CAVITY
PRE-FINISHED SELF DRILLING/TAPPINGSCREW WITH RUBBER WASHER
PRE-FINISHED EXTERNALCORNER FLASHING
BUILDING PAPER SHOWN DASHEDBUILDING PAPER TO PROVIDESEPARATION OF FLASHING ANDCLADDING WITH TIMBER SHOWNDASHED
STRUCTURAL COLUMN BYENGINEER
SUGGEST MIN. 75mm
DIMENSION TO SUIT
SU
GG
EST
MIN
. 75m
m
DIM
ENS
ION
TO
SU
IT
METALCRAFT CORRUGATEHORIZONTAL WALL CLADDING
PRE-FINISHED POP RIVETBEDDED IN SILICONE ORPRE-FINISHED 8g WAFER-TEK SCREW
CONTINUOUS COMPRESSIBLEFOAM SEAL. REFER TO MRM CODEOF PRACTICE VERSION 2.2 /2012FOR REQUIRMENT.
PRE-FINISHED FLAT HEAD WAFER-TEK SCREW FOR FLASHING
PRE-FINISHED SECONDARY FLASHING
ScaleDate Sheet
Corrugate
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.
COMMERCIAL HORIZONTAL CLADDING
CHCG
- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.
1 : 2 16 / 23
EXTERNAL CORNER
2014
METALCRAFT CORRUGATEHORIZONTAL WALL CLADDING
20mm CAVITY
INTERNAL WALL LINING
PRE-FINISHED SELFDRILLING/TAPPING SCREW WITHRUBBER WASHER
BUILDING PAPER SHOWNDASHED
STRUCTURAL COLUMN BYENGINEER
METALCRAFT MSS PURLIN BYENGINEER
MIN. 50mm COVER
MIN
. 50m
m C
OVE
R
5mm
GAP5mm GAP
PRE-FINISHED INTERNAL CORNERFLASHING
CONTINUOUS COMPRESSIBLEFOAM SEAL. REFER TO MRMCODE OF PRACTICE VERSION2.2 /2012 FOR REQUIRMENT.
BUILDING PAPER TO PROVIDESEPARATION OF FLASHING ANDCLADDING WITH TIMBER SHOWNDASHED
PRE-FINISHED FLAT HEAD WAFER-TEK SCREW FOR FLASHING
ScaleDate Sheet
Corrugate
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.
COMMERCIAL HORIZONTAL CLADDING
CHCG
- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.
1 : 2 17 / 23
INTERNAL CORNER BOX TYPE
2014
METALCRAFT CORRUGATEHORIZONTAL WALL CLADDING
20mm CAVITY
PRE-FINISHED SELFDRILLING/TAPPING SCREWWITH RUBBER WASHER
PRE-FINISHED EXTERNALCORNER FLASHING
BUILDING PAPER SHOWNDASHED
STRUCTURAL COLUMNBY ENGINEER
MIN. 50mm COVER
MIN
. 50m
m C
OC
ER5mm
GAP
5mm GAP
BUILDING PAPER TO PROVIDESEPARATION OF FLASHING ANDCLADDING WITH TIMBERSHOWN DASHED
CONTINUOUS COMPRESSIBLEFOAM SEAL. REFER TO MRMCODE OF PRACTICE VERSION 2.2/2012 FOR REQUIRMENT.
PRE-FINISHED FLAT HEADWAFER-TEK SCREW FORFLASHING
METALCRAFT MSS PURLIN BYENGINEER
ScaleDate Sheet
Corrugate
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.
COMMERCIAL HORIZONTAL CLADDING
CHCG
- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.
1 : 2 18 / 23
EXTERNAL CORNER BOX TYPE
2014
BUILDING PAPER SHOWNDASHED
METALCRAFTCORRUGATEHORIZONTAL WALLCLADDING
PRE-FINISHED FLAT HEADWAFER-TEK SCREW FORFLASHING
INTERNAL WALL LINING
METALCRAFT MSS PURLINBY ENGINEER
PRE-FINISHED SOAKERFLASHING BELOWWINDOW JAMBS
METALCRAFT MSS PURLINBY ENGINEER
BUILDING PAPER TOPROVIDE SEPARATIONOF FLASHING ANDCLADDING WITH TIMBERSHOWN DASHED
SOAKER FLASHING ONLY REQUIRED TOLINE UP WITH WINDOW JAMB ABOVE.REFER TO MRM CODE OF PRACTICEVERSION 2.2 /2012 FOR REQUIRMENT.
ScaleDate Sheet
Corrugate
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.
COMMERCIAL HORIZONTAL CLADDING
CHCG
- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.
1 : 2 19 / 23
SOAKER FLASHING
2014
BUILDING PAPER SHOWNDASHED
METALCRAFT CORRUGATEHORIZONTAL WALL CLADDING
PRE-FINISHED SELFDRILLING / TAPPING SCREWWITH RUBBER WASHER
INTERNAL WALL LINING
METALCRAFT MSS PURLIN BYENGINEER
PRE-FINISHED SOAKERFLASHING
METALCRAFT MSS PURLINBY ENGINEER
5mm GAP
MIN. 50mm COVER
BUILDING PAPER TO PROVIDESEPARATION OF FLASHING ANDCLADDING WITH TIMBERSHOWN DASHED
ScaleDate Sheet
Corrugate
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.
COMMERCIAL HORIZONTAL CLADDING
CHCG
- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.
1 : 2 20 / 23
VERTICAL BUTT JOINT
2014
20mm CAVITY
INTERNAL WALL LINING
BUILDING PAPER OVER FLASHINGSHOWN DASHED
METALCRAFT CORRUGATEHORIZONTAL WALL CLADDING
PRE-FINISHED FLAT HEAD WAFER-TEK SCREW FOR FLASHING
PRE-PRIMED SKIRTING
CONCRETE SLAB
METALCRAFT MSS PURLIN BYENGINEER
DR
IP E
DG
E TO
CLA
DD
I NG
MIN
. 15m
m G
AP
MIN
. 50m
m L
AP
BUILDING PAPER TO PROVIDESEPARATION OF FLASHING ANDCLADDING WITH TIMBER SHOWNDASHED
PRE-FINISHED SELFDRILLING/TAPPING SCREW WITHRUBBER WASHER FOR FLASHING
PVC CAVITY CLOSER
VEN
TILA
TIO
N G
AP
3-5m
m
PRE-FINISHED NON-PERFORATEDCLOSER FLASHING WITH 10° FALL
ScaleDate Sheet
Corrugate
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.
COMMERCIAL HORIZONTAL CLADDING
CHCG
- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.
1 : 2 21 / 23
BOTTOM OF CLADDING (FLUSH)
2014
BUILDING PAPER OVER FLASHINGSHOWN DASHED
METALCRAFT CORRUGATEHORIZONTAL WALL CLADDING
PRE-FINISHED SELFDRILLING/TAPPING SCREW WITHRUBBER WASHER
PRE-FINISHED FLAT HEAD WAFER-TEKSCREW FOR FLASHING
INTERNAL WALL LINING
20mm CAVITY
PRE-PRIMED SKIRTING
CONCRETE SLAB
MIN
. 75m
m C
OV
ER
VEN
TILA
TIO
N G
AP
3-5m
m
MIN
. 50m
m L
AP
BUILDING PAPER TO PROVIDESEPARATION OF FLASHING ANDCLADDING WITH TIMBER SHOWNDASHED
ALTERNATIVE OPTIONBIRDS BEAK EDGE
5 GAP
20
15
HEMMED EDGE
PRE-FINISHED NON-PERFORATEDCLOSURE FLASHING WITH 10° FALL
PVC CAVITY CLOSER
ScaleDate Sheet
Corrugate
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.
COMMERCIAL HORIZONTAL CLADDING
CHCG
- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.
1 : 2 22 / 23
BOTTOM OF CLADDING (RECESSED)
2014
ScaleDate Sheet
Corrugate
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.
COMMERCIAL HORIZONTAL CLADDING
CHCG 23 / 23
3D WINDOW FLASHINGS
2014
HEAD FLASHING
JAMB FLASHING
SILL FLASHING
FLUSH WINDOW FLASHINGS RECESSED WINDOW FLASHINGS
HEAD FLASHING
JAMB FLASHING
SILL FLASHING
METALCRAFTCORRUGATEVERTICALCLADDING
ALUMINIUMWINDOWJOINERY
COMPRESSIBLEFOAM SEALBEHIND TO FILLOVERLAP OFFLASHING
METALCRAFTCORRUGATEVERTICALCLADDING
ALUMINIUMWINDOWJOINERY