Transcript
Page 1: ROLP MAXI (ROLPX) ROLP MAXI (ROLPX/SV) 60 - RS Components · 2019. 10. 12. · ROLP MAXI (ROLPX) ROLP MAXI (ROLPX/SV) ROLP 63 S 91 ROLP D+U 0 5 0 60 93 V I C H Li Na Be Mg 42mA max

ROLP MAXI (ROLPX)ROLP MAXI (ROLPX/SV)

63ROLP

S

91ROLP

D+U

0505

6093

VI

CHLi

Na

Be

Mg

42mA max

IP54 = SIP65 = D/U

ROLPX & ROLPX/SV

ABS V0

32

9 ~ 28VDC

-25 c ~ +70 c

20.28mm ~ 2.5mm

2

U D S

Installation must be in accordance with relevantnational wiring regulations or codes for theintended application and voltages employed.

L’installation doit être conforme à la réglementation ou aux codes nationaux de câblage en vigueur, en vue de l’application désirée et des tensions utilisées.Das Gerät ist für die vorgesehene Anwendung und verwendete Spannung gemäß relevanten Bundesvorschriften und Regeln zur Verkabelung zu installieren. L'installazione deve essere eseguita in conformità con le disposizioni nazionali vigenti sul cablaggio o i corrispondenti codici per l'applicazione prevista e le tensioni impiegate,

Installatie moet overeenstemmen met relevantenationale wetgeving of codes voor kabels bij de bedoelde toepassingen en gebruikte voltages.La instalación debe estar acorde con las principales normas nacionales para cableado o códigos para la aplicación prevista y los voltajes empleados.Installation måste ske i enlighet med landets gällande lagar eller bestämmelser för dragning av elektriska kablar till den avsedda enheten och den aktuella spänningenInstalacja musi być wykonana zgodnie zobowiązującymi przepisami prawa i wytycznymizgodnie z pzeznaczeniem sygnalizatora i zwartością zastosowanych napięć

1234567891011121314151617181920212223242526272829303132

111111111011101111001101111010110011100010111

1011010101101001001110010100011000001111011100110101100010110101001001010000011100110001010010000011000100000100000

800 & 970Hz800 ~ 970Hz800 ~ 970Hz

2850Hz2400 ~ 2850Hz2400 ~ 2850Hz500 ~ 1200Hz1200 ~ 500Hz

2400 & 2850Hz970Hz

800 & 970Hz2850Hz970Hz970Hz

554 & 440Hz660Hz660Hz660Hz660Hz

554 & 440Hz660Hz2850Hz

800 ~ 970Hz2400 ~ 2850Hz

970Hz800 ~ 970Hz970 & 800Hz800 & 970Hz990 & 650Hz510 & 610Hz300 ~ 1200Hz510 & 610Hz

Tones)

14134037384235203814143714

36179

1111111711

2913372020151320203217

1

101102107107111112107102107101101107100104102100101101101102101105101110104106104101 04

101103101

BS Fire ToneBS Fire ToneBS Fire Tone

BS Fire ToneBS Fire ToneBS Fire Tone

Dutch Fire ToneTDin one

BS Fire Tone

BS Fire ToneFrench Fire Tone

Swedish Fire ToneSwedish Fire ToneSwedish Fire ToneSwedish Fire ToneSwedish Fire ToneSwedish Fire TonePelican Crossing

BS Fire Tone

ISO 8201ISO 8201

mA dB(A)

@20 c

Fulleon Ltd, Cwmbran, South Wales, U.K.www.cooperfulleon.com

1 2

25-8292-E

14141414441414414

41414141617181920211414425262710

988Hz510Hz

14510Hz

14

2Hz (250ms~250ms)7Hz (7/s)1Hz (1/s)Steady7Hz1Hz3.5s Sweep, 0.5s silence, then repeat1Hz2Hz (250ms~250ms)0.5Hz (1s On / 1s Off)1Hz (500ms~500ms)0.5Hz (1s On / 1s Off)0.8Hz (250ms On / 1s Off)Steady100ms ~ 400ms3.3Hz (150ms On / 150ms Off)0.28Hz (1.8s On / 1.8s Off)0.05Hz (13s Off / 6.5Hz On)Steady0.5Hz (1s On / 1s Off)1Hz (500ms ~ 500ms)4Hz (150ms On / 100ms Off)50Hz50Hz3 x 500ms pulses followed by 1.5s silence then repeat3 x 500ms pulsed sweep followed by 1.5s silence then repeat

2Hz (250ms ~ 250ms)2Hz (250ms ~ 250ms) (Symphoni 2Hz (250ms ~ 250ms) (Squashni Micro Tones) 1Hz1Hz (500ms ~ 500ms)

3 x 500ms pulsed two tone followed by 1.5s silence then repeat ISO 8201

1

2

3

+VDC

-V DC

-V DC

1

2

+VDC

-V DC

-V DC

ROLPX/SV

1

2ROLPX

6 Way Switch Variants

HighVolLowVol

ON CIT

2 3 4 5 611

2

2 3 4 5 61

1 1 1 10

1

VOL

HighVolLowVol

ON CIT

1 2 3 4 51 2 3 4 5V

1 1 1 10

1

Example of Tone 3 setting

5 Way Switch Variants

ON CIT

1 2 3 4 51

2 3 4 51

1 1 10

1

Example of Tone 3 setting

ROLPX/SV

ROLPX

Top Related