Transcript
  • RESILIENT WEDGE VALVES

    CLOW VALVE COMPANY

    CLOW AWWA Resilient Wedge Gate

    Valves Meet or Exceed the Requirements

    of AWWA Standard C509

    Size Range Water Working

    Pressure psi

    Bubble Tight

    Test psi

    Hydrostatic Shell

    Test psi

    AWWA2"-12"

    250

    250

    500

    ULFM 21/2"-12"

    200

    200

    400

    Available in either non-rising stem, outside screw & yoke.

    Available End Connections & Size Range

    FLG End (NRS) 2"-12"

    M.J. 2"-12"(except 21/2'') FLG & M.J. 3"-12" Push-on for PVC (SDR) 2"-12"

    FLG End (OS & Y) 2"-12"

    M.J. for Tapping 3"-12"

    Tyton for D.l. & C900 PVC 4"-12"

    M.J. Cutting-in 4"-12"

    Tyton for D.l. X FLG 4"-12"

    Threaded 2"-3"

    Accessories (Illustrated in the in Plant Valve Section)

    Indicator Posts 2" Sq. Operating Nuts "T" Handles Handwheels Stem Guides Extension Stems Electric Motor Actuators Floor Boxes

    Chain Wheels Floorstands (non-rising stem)

    Figure No.

    F-6102

    F-6100

    F-6106 F-6110 F-6136

    F-6114

    F-6112

    F-6111

    F-6113

    F-6103

    MODEL 2639 AWWA

    MODEL 2640 AWWA

    C509 FULL BODY DUCTILE IRON

    C509 FULL BODY GRAY IRON

  • RESILIENT WEDGE VALVES

    CLOW VALVE COMPANY

    CLOW AWWA Resilient Wedge Gate Valves Meet or Exceed the Requirements of AWWA

    Standard C515

    Size Range

    Water Working

    Pressure psi

    Bubble Tight

    Test psi

    Hydrostatic Shell

    Test psi

    AWWA4"-48"

    250

    250

    500

    ULFM 4"-16"

    200

    200

    400

    Available in either non-rising stem, outside screw & yoke.

    Available End Connections & Size Range

    FLG End (NRS) 4"-48"

    M.J. 4"-48"(except 21/2") FLG & M.J. 4"-48" Push-on for PVC (SOR) 4"-12"

    FLG End (OS & Y) 4"-24" M.J. for Tapping 4"-24"

    Tyton for 0.1. & C900 PVC 4"-12" & 16"

    M.J. Cutting-in 4"-12"

    Tyton for 0.1. X FLG 4"-12"

    Accessories (Illustrated in the In Plant Valve Section)

    Indicator Posts 2" Sq. Operating Nuts Enclosed Gearing (14"-24") Handwheels

    "T" Handles Extension Stems Stem Guides Floor Boxes Electric Motor Actuators Chain Wheels

    Floorstands (non-rising stem)

    Figure No.

    F-6102 F-6100

    F-6106

    F-6110

    F-6136

    F-6114

    F-6112

    F-6111

    F-6113

    MODEL 2638 AWWA C515 REDUCED WALL DUCTILE IRON

    NOTE: It is recommended that valves be installed with

    stems vertical when used in

    raw sewage or sludge

    applications or in water with

    excessive sediment.

  • clow-rw-gateclow-rw-gate-valves-pressure-rtings-available-styles-ao0x8 2 2clow-rw-gate-valves-pressure-rtings-available-styles-ao0x8 2 1clow-rw-gate-valves-pressure-rtings-available-styles-ao0x8 2 3