Residential building Application – Prefabricated house with 2 floors –
EasySens® Example – Room LayoutResidential building Application – prefabricated house with 2 floors
EasySens® Example – Room LayoutResidential building Application – prefabricated house with 2 floors
Switch MiniLight & Blind
Switch MiniLight & Blind
Switch MiniLight
Switch MiniLight & Blind
Switch MiniLight & Blind
Switch MiniLight
Switch MiniLight & Blind
Switch MiniLight & Blind
Switch MiniLight & Blind
Switch MiniLight & Blind
Switch MiniLight
» underfloor heating
Switch MiniLight
Switch MiniLight
Switch MiniLight
Switch MiniLight & Blind
Switch MiniLight
Switch MiniLight
Switch MiniLight
Switch MiniLight
Switch MiniLight
Roomtemperature
sensor
Roomtemperature
sensor
Roomtemperature
sensor
Roomtemperature
sensor
Roomtemperature
sensor
Roomtemperature
sensor
Roomtemperature
sensor
Roomtemperature
sensor
» lighting dimmable » lighting switchable » socket switchable
EasySens® Example – FunctionalityResidential building Application – prefabricated house with 2 floors
Blinds underfloorheating
socket switchable
Lights(groups)
Dim(groups)
Ground Kitchen / living room 2 1 3 1floor Guest bathroom 1 1 1
Office 1 1 1Utility Room 1 1 1Floor (Ground floor) 1 1
Top Master bedroom 1 1 2 1 1floor Children's room 1 1 1 1 1 1
Children's room 2 1 1 1 1 1Guest bathroom 1 1 1Floor (Top floor) 1
Total 10 8 4 12 4Total data points 20 8 4 12 4
DO DO DO DO AO
Operation / Controls
HVAC Lights Blinds Scenes
Outputs
EasySens® Example – SolutionResidential building Application – prefabricated house with 2 floors
OPERATION (TRANSMITTERS) QTY Remark
SR07PTemperature room unit with setpoint potentiometer
8
Mini 2-ch Light 2-channel light switch; pure white brilliant 3
Mini 4-ch Light 4-channel light switch; pure white brilliant 8
Mini 4-ch Light/Blinds2-channel light, 2-channel blinds switch; pure white brilliant
9
OUTPUTS (RECEIVERS)
STC-DO8 Digital ouput module with 8 DO's (Type 3) 3all lights,
blinds
STC-DO8 Digital ouput module with 8 DO's (Type 1) 1 floor heating
STC-PLUS 4DO Digital output add-on module for STC-DO8 2
STC-ADO Universal (DO/AO) output module 10-10VDC setpoint
EasySens® Example – Panel LayoutResidential building Application – prefabricated house with 2 floors
» Ground floor
EasySens® Example – Panel LayoutResidential building Application – prefabricated house with 2 floors
» Top floor
EasySens® Example – Panel WiringResidential building Application – prefabricated house with 2 floors
» Wiring „heating“
Heating H1 Heating H2 Heating H3 Heating H4 Heating H5 Heating H6 Heating H7 Heating H8
FUSE
N +
POWER SUPPLY
LL 24
VDC-
N
STC-DO8 Typ124V GND
1NC 1NO 1C 2NC 2NO 2C 7NC 7NO 7C5NC 5NO 5C 6NC 6NO 6C3NC 3NO 3C 4NC 4NO 4C 8NC 8NO 8C
R7 R8R1 R2 R3 R4 R5 R6
EasySens® Example – Panel WiringResidential building Application – prefabricated house with 2 floors
» Wiring „lights“
Lights L1 Lights L2 Lights L3 Lights L4 Lights L5 Lights L6 Lights L7 Lights L8 Lights L9 Lights L10 Lights L11 Lights L12
FUSE
R12R11R10R9R7 R8R2R1 R5
POWER SUPPLY
R4R3
LN
L 24 VDC
-N +
BNC BNO6C 7NC 7NO5NC 5NO 5C 6NC 6NO DC
STC-DO8 Typ3 STC-PLUS 4DO24V GND
BC CNC CNO CC DNC DNO8C ANC ANO AC2C 3NC 3NO 3C 4NC 4NO1NC 1NO 1C 2NC 2NO 7C 8NC 8NO4C
R6
EasySens® Example – Panel WiringResidential building Application – prefabricated house with 2 floors
» Wiring „blinds“
N DW UP N DW UP N DW UP N DW UP
N1 N1
L1 L1
NO C NO C NO C NO C
NC NC
L1
N1
E E E N DW UP E
Blind 1 Blind 1
E E N DW UP
Cut-off relay TR1 Cut-off relay TR21N 2N 1DW 2DW 1UP 2UP1N 2N 1DW 2DW 1UP 2UP
R1 R2 R7 R8
1NC 1NO 1C 2NC 2NO 2C 3NC 3NO 8NO 8C
STC-DO8 Typ3POWER SUPPLY
GND 24V
5C 6NC 6NO 6C 7NC 7NO3C 4NC 4NO 4C 5NC 5NO 7C 8NC
Blind 4
2UP
L Fused
Breake
rL 24
VDC-
NN +
Cut-off relay TR7 Cut-off relay TR81N 2N 1DW 2DW 1UP
Blind 4
E E E N DW UP E E E
1N 2N 1DW 2DW 1UP 2UP
N DW UP
EasySens® Example – Panel WiringResidential building Application – prefabricated house with 2 floors
» Wiring „sockets (dim)“Socket S1 Socket S2 Socket S3 Socket S4
L1
N1
Dim Dim Dim Dim Light L1 Light L9 Light L10 Light L11
SRC-ADO 4AA / 4DA6 C 7
AO48 C1
AO12 C 3
AO24 C
17C 18NC 19NO 20C
L Fused
Breake
rL 24
VDC-
NN +
5 AO3
POWER SUPPLYGND 24V
9NC 10NO 11C 12NC 13NO 14C 15NC 16NO
R1 R2 R3 R4
EasySens® Example – Devices (overview)Residential building Application – prefabricated house with 2 floors
Please visit us online www.thermokon.comMany thanks for your attention!
This presentation document is solely made up for internal use by the management and the employees. Distribution, reproduction andcitation to third parties – even excerpts from this presentation – are forbidden and only allowed after explicit consent of Thermokon
Sensortechnik. Violations will be prosecuted by copyright.