Variable Speed DC Compressors and Condensing Units
www.tecumseh.com
COMPANY CONFIDENTIAL. INTERNAL USE ONLY.
RK2/RN2 Series Compressor
Reference Guide
2
RK2/RN2 Compressor Reference GuideRK2/RN2 Compressor Reference Guide
PROVEN RELIABILITYPrecision matching combined
with automated assembly and testing
ensures that each and every compres-
sor is built to exacting standards
LOW NOISEStable / low vibration
mechanism and reduced
friction cylinder components
minimizes noise.
VERSATILE Wide operating temperature and voltage
range, combined with high torque motor,
allows use in most geographic areas.
REDUCED ENERGYHigh efficiency motors
coupled with optimized
pumping mechanisms results
in industry leading
compressor EERs.
APPLICATION FLEXIBILITYOver-sized accumulator
accommodates large refrigerant
charge needed in longer line runs
RUGGEDDesigned to operate in extreme conditions. Suit-
able for Super Tropical (T3) ambient
temperature (129°F / 54°C).
3 COMPANY CONFIDENTIAL. INTERNAL USE ONLY.
RK2/RN2 Compressor Reference GuideRK2/RN2 Compressor Reference Guide
TABLE OF CONTENTS
RK2/RN2 Series Compressors ......................................................................................................................... 2
Overview ........................................................................................................................................................ 3
RK2/RN2 Series Model Compressor Nomenclature ......................................................................................... 4
RK2/RN2 Series Model BOM Nomenclature .................................................................................................... 4
Compressor Label Configurations.................................................................................................................. 5
Pallet Packageing ........................................................................................................................................... 5
RK2/RN2 Series Model Compressor Dimensions ............................................................................................ 6
Performance Specification.............................................................................................................................. 8
Tecumseh Cross Reference ............................................................................................................................ 9
Typical Applications ..................................................................................................................................... 10
Notes............................................................................................................................................................ 11
RK2/RN2 Series Model Installation Instructions ............................................................................................ 12
OVERVIEW• The innovative design delivers high efficiency performance with an evaporating range of -10°F to 55°F
(-23.3°C to 12.8°C).
• RK2 compressors are charged with 56 cst viscosity POE oil. RN2 compressors are charged with 68 cst viscosity POE oil. Both provide superior lubrication suitable for all approved HC, HFC, and HFO refrigerants.
• All models have either a Permanent Split Capacitor (PSC) or 3 phase motors.
• Primary model voltages are XV, NA, FB, AA, and FZ.
• RK2/RN2 series compressors, 60hz, are UL recognized for United States and Canada under file number SA707.
4
RK2/RN2 Compressor Reference GuideRK2/RN2 Compressor Reference Guide
COMPRESSOR MODEL NOMENCLATURE
Family
RK2 Series, RN2 Series
Application5 Air Conditioning / Heat Pump
CapacityFirst digit is the number of digits in Rated
Btu/h Capacity. Next two digits are the first
two digits in Rated Btu/h Capacity.
This example: 12,000 Btu/h at 60 Hz
RK 5 512 B - XV 3 A
Release Variant
Motor Type 3 PSC
1 3 Phase
Approved Voltage
XV 265/60/1
NA 208-230/60/1
AA 115/60/1
FB 220/60/3
FZ 220-240/50/1
RefrigerantB R410A
Y R134a
E R22
RK2 RN2 SERIES BOM NOMENCLATURER K 5 B F 1 K C 1 2 0 A 4 0
Compressor Series Application Refrigerant Displacement
CodeModel Variant Voltage Country
of OriginCompressor
HousingPackType
ProcessCode
B: R410AY: R134aE: R22
1 Current2 Future3 Future
C: China
A: Pallet Pack
By Region: See BOM structure
A: AAD: NAF: FZK: XVS: FB
5: A/C
5 COMPANY CONFIDENTIAL. INTERNAL USE ONLY.
RK2/RN2 Compressor Reference GuideRK2/RN2 Compressor Reference Guide
COMPRESSOR LABEL CONFIGURATION
A – January D – April G – July K – OctoberB – February E – May H – August L – NovemberC – March F – June J – September M – December
Electrical RatingVolts/Hertz
LRA (Locked Rotor Amps)
Code DateLetter indicates monthNext 2 digits indicate day of monthLast 2 digits indicate year
Model Number
Serial Number
Warning/Danger
Overload Protector Type (Internal or External)
Bill of Material NumberRefrigerant Type
Frame SizeCompressor Quantity (Pcs)
Pallet Qty. 1 Pallet Height 1 Pallet Qty. 2 Pallet Height 2
39 36 21 in. 72 35 in.
44 36 21 in. 72 35 in.
48 30 24 in. 60 42 in.
55 20 27 in. 40 47 in.
63 12 27 in. 24 47 in.
PALLET PACKAGINGCompressors must be ordered in full pallet quantities. Two different pallet configurations are available
6
RK2/RN2 Compressor Reference GuideRK2/RN2 Compressor Reference Guide
DIMENSIONSAll dimensions are in inches and [mm].
ID ID
10.0”
6.9”
[253]
[176]
13.8”[351]
12.2”
DISCHARGE - COPPER.378” - .385” ID[9.6- 9.8]
SUCTION - COPPER.502” - .509”[12.8 13.0]
[311]
120o
30o
O .787” [20] (Typical 3)
R 3.5” [88]
RK2 Series(48 Frame)
8.1”
5.9”
[205]
[149]
12.4”[316]
11.4”
DISCHARGE - COPPER.317”- .324” ID[8.1- 8.2]
SUCTION - COPPER.502”- .509”[12.8 - 13.0]
[290]
120o
30o
O .787” [20] (Typical 3)
R 3.0” [75]
RK2 Series(44 Frame)
7 COMPANY CONFIDENTIAL. INTERNAL USE ONLY.
RK2/RN2 Compressor Reference GuideRK2/RN2 Compressor Reference Guide
DIMENSIONSAll dimensions are in inches and [mm].
ID
10.4”
7.2”
[263]
[183]
13.6”[346]
12.7”
DISCHARGE - COPPER.378”- .385” ID[9.6- 9.8]
SUCTION - COPPER.628”- .635”[15.9 - 16.1]
[324]
120o
30o
O .787” [20] (Typical 3)
R 3.5” [88]
RN2 Series(55 Frame)
90o
7.5.787
15o
7.59.5
11.4
45o
[291]
[135]
[190][240]
[20]
R 5.3
4x
[190]
[423]
SUCTION - COPPER.752-.758 I.D.[ 18.9-19.3 ]
DISCHARGE - COPPER.508-.515 I.D.[ 12.9-13.1 ]
16.6[423]
17.2[436]
63 FRAME - RN2
90o
7.5.787
15o
7.59.5
11.4
45o
[291]
[135]
[190][240]
[20]
R 5.3
4x
[190]
[423]
SUCTION - COPPER.752-.758 I.D.[ 18.9-19.3 ]
DISCHARGE - COPPER.508-.515 I.D.[ 12.9-13.1 ]
16.6[423]
17.2[436]
63 FRAME - RN2
RN2 Series(63 Frame)
8
RK2/RN2 Compressor Reference GuideRK2/RN2 Compressor Reference Guide
PERFORMANCE SPECIFICATION
R134A
Model No. Volt/Hz/Ph* Cooling Capacity Displacement Frame EER
BTU/H W CC/REV mm BTU/WH
RK5512Y-AA3A 115/60/1 11,854 3,474 24.0 48 11.4
RK5512Y-NA3A 208-230/60/1 12,000 3,517 24.0 48 11.0
RK5518Y-NA3A 208-230/60/1 18,000 5,275 XX 55 10.7
R22
Model No. Volt/Hz/Ph* Cooling Capacity Displacement Frame EER
BTU/H W CC/REV mm BTU/WH
RK5480E-AA3A 115/60/1 8,000 2,345 11.3 39 10.6
RK5480E-NA3A 208-230/60/1 8,000 2,345 11.3 39 10.7
RK5511E-FZ3A 220/50/1 8,900 2,608 15.0 44 10.7
RK5490E-AA3A 115/60/1 9,350 2,740 13.2 44 10.7
RK5490E-NA3A 208-230/60/1 9,400 2,755 13.2 44 10.6
RK5510E-AA3A 115/60/1 10,100 2,960 14.1 44 10.7
RK5510E-NA3A 208-230/60/1 10,260 3,007 14.1 44 10.8
RK5513E-AA3A 115/60/1 12,650 3,707 17.6 44 10.7
RK5513E-NA3A 208-230/60/1 12,650 3,707 17.6 44 10.6
RK5515E-FZ3A 220/50/1 12,400 3,634 21.0 48 11.1
RK5514E-AA3A 115/60/1 13,400 3,927 18.7 44 10.6
RK5514E-NA3A 208-230/60/1 13,400 3,927 18.7 44 10.5
RK5516E-NA3A 208-230/60/1 15,800 4,631 21.7 48 10.9
RK5519E-NA3A 208-230/60/1 18,700 5,480 25.8 48 10.7
R410A
Model No. Volt/Hz/Ph* Cooling Capacity Displacement Frame EER
BTU/H W CC/REV mm BTU/WH
RK5512B-XV3A 265/60/1 12,050 3,532 11.5 44 10.5
RK5515B-XV3A 265/60/1 14,800 4,337 13.9 44 10.3
RK5515B-NA3A 208-230/60/1 14,850 4,352 13.9 44 10.1
RK5518B-NA3A 208-230/60/1 18,100 5,305 17.0 48 10.8
RK5520B-NA3A 208-230/60/1 20,400 5,979 19.0 48 10.6
RN5525B-NA3A 208-230/60/1 25,300 7,415 23.9 55 10.7
RN5530B-NA3A 208-230/60/1 29,800 8,734 27.9 55 10.6
RN5533B-NA3A 208-230/60/1 32,500 9,525 30.6 55 10.3
RN5537B-NA3A 208-230/60/1 37,000 10,844 35.1 55 9.8
RN5549B-FB1A 220/60/3 49,300 14,449 46.3 63 10.1
RN5565B-FB1A 220/60/3 65,350 19,153 61.5 63 9.9
*ASHRAE Rating Conditions: 95°F (35°C) ambient temperature, 45°F (7°C) evaporator temperature, 130°F (45°C) condenser temperature, 95°F (35°C) return gas temperature, 115°F (46°C) liquid temperature
9 COMPANY CONFIDENTIAL. INTERNAL USE ONLY.
RK2/RN2 Compressor Reference GuideRK2/RN2 Compressor Reference Guide
TECUMSEH CROSS REFERENCER22
Legacy Model New Model Volt/Hz/PhInput Disp. Height Weight *A/C
Capacity A/C Sound
(Watt) (cc) (in) (lbs) BTU/hr EER dBA
RKA5480EXA RK5480E-AA3A 115/60/1 755 11.3 10.2 18.4 8,000 10.6 55
RKA5480EXD RK5480E-NA3A 208-230/60/1 748 11.3 10.2 18.4 8,000 10.7 55
NO LEGACY PRODUCT RK5511E-FZ3A 220/50/1 832 15 11 24.7 8,900 10.7 52
RKA5490EXA RK5490E-AA3A 115/60/1 874 13.2 10.2 22.5 9,350 10.7 55
RKA5490EXD RK5490E-NA3A 208-230/60/1 886 13.2 11.2 24.6 9,400 10.6 55
RKA5510EXA RK5510E-AA3A 115/60/1 944 14.1 11.2 22.5 10,100 10.7 55
RKA5510EXD RK5510E-NA3A 208-230/60/1 950 14.1 10.4 24.6 10,260 10.8 55
RKA5512EXA RK5513E-AA3A 115/60/1 1,182 17.6 11.2 26.2 12,650 10.7 56
RKA5512EXD RK5513E-NA3A 208-230/60/1 1,193 17.6 12.1 26.6 12,650 10.6 56
NO LEGACY PRODUCT RK5515E-FZ3A 220/50/1 1,117 21.0 12.8 34.8 12,400 11.1 56
RKA5513EXA RK5514E-AA3A 115/60/1 1,264 18.7 11.5 26.2 13,400 10.6 56
RKA5513EXD RK5514E-NA3A 208-230/60/1 1,276 18.7 11.5 26.0 13,400 10.5 56
RKA5515EXD RK5516E-NA3A 208-230/60/1 1,450 21.7 12.8 33.3 15,800 10.9 59
RKA5518EXD RK5519E-NA3A 208-230/60/1 1,748 25.8 12.8 34.6 18,700 10.7 60
R134a
Legacy Model New Model Volt/Hz/PhInput Disp. Height Weight *A/C
Capacity A/C Sound
(Watt) (cc) (in) (lbs) BTU/hr EER dBA
RKA5512YXA RK5512Y-AA3A 115/60/1 1,038 24.0 12.4 32.2 11,854 11.4 XX
RKA5512YXD RK5512Y-NA3A 208-230/60/1 1,091 24.0 12.4 32.2 12,000 11.0 61.0
NO LEGACY PRODUCT RK5518Y-NA3A 208-230/60/1 XX XX XX XX 18,000 10.7 XX
*ASHRAE Rating Conditions: 95°F (35°C) ambient temperature, 45°F (7°C) evaporator temperature, 130°F (45°C) condenser temperature, 95°F (35°C) return gas temperature, 115°F (46°C) liquid temperature
10
RK2/RN2 Compressor Reference GuideRK2/RN2 Compressor Reference Guide
TYPICAL APPLICATIONSThe RK2/RN2 has an evaporating temperature range of -10°F to +55°F (-23°C to +12.80°C).
PTAC
Found in hotels, hospitals, apartment buildings and self-contained
air conditioning systems.
RK2/RN2
Ice Machine
Found in hotels, motels and resorts as well as
commercial kitchens to dispense ice.
DuctlessMinisplits
Provides zoned heating and cooling for
residential and commercial buildings.
HVAC
Heats and cools homes and commercial
buildings (ex. heat pumps condensing units
packaged rooftops).
11 COMPANY CONFIDENTIAL. INTERNAL USE ONLY.
RK2/RN2 Compressor Reference GuideRK2/RN2 Compressor Reference Guide
Notes:
12
RK2/RN2 Compressor Reference GuideRK2/RN2 Compressor Reference Guide
RK2/RN2 SERIES COMPRESSOR INSTALLATION INSTRUCTIONS
Terminal Pin Orientation
WARNINGNever service, repair, or troubleshoot unless you are qualified to perform these functions. Improper servicing can lead to serious injury or death from fire, electrical shock, or explosion.
!Run
Start
Common
PSC
S (V)
C (W)
R (U)
3 Phase
Exploded View of Assembly
Items Comp. withExternal OLP
Comp. withInternal OLP
Nut qCover Terminal w e
Overload Protector rSpring etc - OLP t
Gasket y u
Grommet Isolator i i
Sleeve o oo
w
q
e
ty
u
i
r
GROUND CONNECTION
13 COMPANY CONFIDENTIAL. INTERNAL USE ONLY.
RK2/RN2 Compressor Reference GuideRK2/RN2 Compressor Reference Guide
Electrical Wiring Diagram - PSC (External Overload)
Electrical Wiring Diagram - PSC (Internal Overload)
ELECTRICAL COMPONENTS Use only new electrical components specific for this compressor model.
ELECTRICAL COMPONENTS Use only new electrical components specific for this compressor model.
Electrical Wiring Diagram - 3 Phase
EXTERNAL
14
RK2/RN2 Compressor Reference GuideRK2/RN2 Compressor Reference Guide
NEW INSTALLATION TIPS* Upon receipt of your new compressor check for damage from shipping. Report any damage immediately to your local Tecumseh
Authorized Wholesaler.
* Check the name plate for correct voltage, phase, frequency, and refrigerant for the intended use BEFORE installation.
* Check compressor windings for correct ohm’s readings and short circuit to ground BEFORE installation. Keep the following in mind:
- Power to unit must be off - Removing wires to expose terminals can lead to mis-wiring, replace correctly - Securely replace protective cover
* Warning labels are provided to inform and protect persons servicing Tecumseh equipment. Care must be taken not to damage or destroy labels during installation. Damaged or missing labels should be replaced with approved labels from your Tecumseh Authorized Wholesaler.
CAUTION: SAFETY FIRST* DO NOT INSTALL, service, repair, or troubleshoot an air conditioning or refrigeration system without proper certification and approval from authorities (Local, State, Federal).
* YOU MUST have the necessary knowledge, training and equipment.
* DISCONNECT ELECTRICAL POWER before removing the protective cover of any electrical terminal.
* DO NOT RE-CONNECT electrical power unless the protective covers of all electrical terminals are in place and securely fastened.
* DO NOT OPERATE compressor or connect electrical power, unless it is connected to ground.
* DO NOT RESET A BREAKER or replace a fuse without first checking for ground fault (short circuit to ground).
* An open fuse or tripped circuit breaker is a strong indication of a ground fault, also known as a short circuit to ground.
* If a ground fault does exist, keep the power off and find and repair. Use only a Mega Ohmmeter (“megger”) or a Hi-potential ground tester (“Hi-Pot”) to check for a ground fault. A conventional ohmmeter will not reliably detect an insulation breakdown causing the ground fault.
* Never expose system to leak test pressures greater than 150 psig (11.4 bar abs).
* Never overcharge system with refrigerant. Overcharging with refrigerant may lead to excessive pressures and rupture of terminal block may occur. Always use proper charging techniques and limit charge amounts to those specified on the system equipment serial label or in the original equip ment manufacturer’s service information.
* Contact with refrigerant, mixtures of refrigerant and oil, or other chemicals can cause a variety of injuries including burns and frostbite.
* Oil and refrigerant can spray from compressor electrical terminals and be ignited by electricity or other sources of ignition causing serious INJURY or DEATH.
GENERAL INSTALLATION INSTRUCTIONS* Prior to removal of current compressor please refer to Tecumseh’s Service Handbook to verify compressor requires replacement.
The Service Handbook is available online at www.tecumseh.com.
* Tubing sizes and orientation may vary between compressors and applications.
* Use only electrical start components supplied with this replacement compressor. Do Not Reuse Electrical Components! Use Only New Electrical Components.
* Tecumseh recommends using provided replacement mounting grommets and hardware.
* Install a properly sized filter-drier for the system being serviced.
* Evacuate to a minimum of 500 microns. Always use a vacuum gauge to measure vacuum levels.
15 COMPANY CONFIDENTIAL. INTERNAL USE ONLY.
RK2/RN2 Compressor Reference GuideRK2/RN2 Compressor Reference Guide
* This compressor is shipped with a holding charge of nitrogen or dry air. Remove the holding charge only after the equipment has been installed with connecting tubing and a new filter-drier installed. Purge the holding charge thru a service port. DO NOT leave the unit open to the atmosphere for an extended period of time, to do so will contaminate the oil and cause excessive evacuation time, and could cause premature failure.
* Be sure to use clean, refrigeration tubing with both ends sealed.
* Remove discharge tube hang tag prior to brazing. Cut, form and braze tubes carefully to avoid getting dirt and/or metal filings into the lines. When sizing suction and liquid lines, consult the refrigerant line sizing section of the Tecumseh Hermetic Service Handbook, or use the Tecumseh refrigerant line sizing app located at http://boxload.tecumseh.com/ Whenever possible, pitch the suction line downward in the direction of flow, approximately 1/2’’ for each 10 ft length, to aid in oil drainage. Avoid line lengths in excess of 100 ft. Contact Tecumseh Technical Service for assistance.
* When you open the system, complete the service operation as quickly as possible so it will not be exposed to the air longer than necessary.
* Once all connections have been made, leak test with regulated dry nitrogen or other approved gas to a pressure not to exceed 150 psig (11.4 bar abs). Repair any leaks and leak test again.
* When system is leak free, connect a vacuum pump capable of at least 500 microns vacuum to both sides of the system. Evacuate to at least 500 microns for a minimum of 30 min. Vacuum levels should be measured with an electronic gauge.
* Do not operate the compressor without a charge in the system. Operating the compressor without a charge in the system can damage the hermetic terminals. To avoid serious injury or death from terminal venting with ignition, DO NOT energize the compressor unless the protective cover is securely fastened.
* CAUTION!!! Only use refrigerant indicated on serial label when charging the system. Using a different refrigerant can lead to excessive system pressure and/or an explosion. Use of a refrigerant other than the serial label refrigerant will void the warranty.
COMPRESSOR REPLACEMENT TIPS * Disconnect all electrical power supplies to the system, making sure all power legs are open.
(NOTE: The system may have more than one power supply.)
* Be sure all refrigerant is recovered before removing the compressor. Attempting to remove the compressor before removing all refrigerant from the system can cause a sudden release of refrigerant and oil. Among other things, this can cause a variety of injuries including burns and frostbite, a fire, and expose the service person to toxic gas.
* Install a properly sized filter-drier for the system being serviced.
* Use only regulated dry nitrogen or dry nitrogen with trace amounts of the serial label refrigerant to purge and/or leak test the system to a pressure not to exceed 150 psig (11.4 bar abs).
QUESTIONS AND SUPPORTTecumseh Tech Support: 800.211.3427 or Email: [email protected]
Tecumseh reserves the right to change any information in this publication at any time.
This document is not intended to replace the training required for professional service personnel, or replace other information available from refrigeration and air conditioning equipment manufacturers. The information in this document is intended to assist service personnel in safely installing and servicing Tecumseh RK2 RN2 compressor. Mounting, tubing, and electrical connections are likely to differ from original installation. Careful review of current appli-cation requirements is essential. IT IS THE RESPONSIBILITY OF THE SERVICE PERSON TO ASSURE THEY HAVE PURCHASED A REPLACEMENT PRODUCT WHICH MEETS THE NEED OF THE APPLICATION. Failure to do so may result in misapplication requiring immediate or subsequent additional compressor replacement.
©2018 Tecumseh Products Company LLC. All rights reserved. TP-020 USA LT_ RK2_RN2 Reference Guide_V2 0 060418
TECUMSEH COMPRESSOR COMPANY LLC
NORTH AMERICAN HEADQUARTERS SALES AND MARKETING5683 Hines DriveAnn Arbor, MI 48108ph.: 734.585.9500ph.: 800.211.3427
CANADA SALES200 Elm StreetAylmer, Ontario N5H 2M8ph.: 519.765.1556fax: 519.765.1574
TECHNICAL SERVICESph.: 800.211.3427
North America: [email protected]: [email protected]
For more information on products by Tecumseh,please visit our website www.tecumseh.com