ELECTROMAGNETIC COMPATIBILITY TEST
Report reference N° R-21 EMC 2012
Constructor .………………………………………………
Address ……………………………………………………
Reference person……………………………………….
A.S. Distribuzione S.r.l. Via Turati, 8 40134 Bologna Italy
----
Product ……….................………..........………….
Model ………………........................……………….
Type …………………..…………………………….……. Serial number …………….....................…………
Rating ……………......................…………………..
Nebulizer Disinfectant for Surfaces
99.99M
---- M 17470392
230V ~ 50/60Hz 1000W
Date of receipt of test item ................…………. Date of performance of test ................………… Date of test report …………..................………….
05-01-12 11-01-12 ÷ 13-01-12
23-01-12
Reference standard ...........................………….
EN 55014-1: 2006 + A1: 2009 EN 55014-2: 1997 + A1: 2001 + A2: 2008
EN 61000-3-2: 2006 + A1: 2009 + A2: 2009
EN 61000-3-3: 2008 EN 61000-4-2: 2009
EN 61000-4-4: 2004 + A1: 2010 EN 61000-4-5: 2006
EN 61000-4-6: 2009
EN 61000-4-11: 2004
Final result
COMPLIANT
Compiled by Testing Engineer
……………………….…....…………… (Marco Casiraghi)
Checked by
…………………….…....…………… (Federico Sirtori)
The test results recorded in this test report are exclusive referred to the tested samples. No part of this test report may be reproduced without prior written consent of Eletech.
ELETECH S.r.l. Via Garcia Lorca 29 23871 Lomagna (LC) Italy Tel. 0039.039.99340.1 Fax. 0039.039.9991289
e-mail: [email protected] - http:www.eletechsrl.it
Constructor Product Report reference Date of test report Page
A.S. Distribuzione S.r.l. 99.99M R-21 EMC 2012 23-01-2012 2 of 41
ELETECH S.r.l. Via Garcia Lorca 29 23871 Lomagna (LC) Italy Tel. 0039.039.99340.1 Fax. 0039.039.9991289 e-mail: [email protected] - http://eletechsrl.it
1. Report index
Report index Page
1. Report index 2
2. General condition 3
3. Equipment under test 4 - 5
4. Test condition 6 - 7
5. Reference standard 8
6. Instruments 9
7. Uncertainty 10
8. Summary of result 11 - 12
9. Emission
9.1. Emission measurement: continuous disturbance 13 - 15
9.2. Emission measurement: discontinuous disturbance 16 - 17
9.3. Emission measurement: disturbance power 18 - 24
9.4. Emission measurement: electromagnetic radiation disturbance
9.5. Emission measurement: harmonics currents 25 - 27
9.6. Emission measurement: voltage fluctuation and flicker 28 - 29
10. Immunity
10.1. Immunity test: electrostatics discharger ESD 30 - 31
10.2. Immunity test: radiated RF electromagnetic field 32
10.3. Immunity test: electrical fast transients, burst 33
10.4. Immunity test: surge 34 - 35
10.5. Immunity test: conducted disturbance, induced RF field 36 - 37
10.6. Immunity test: voltage dips and short interruptions 38
11. Photo 39 - 40
12. Modify 41
Constructor Product Report reference Date of test report Page
A.S. Distribuzione S.r.l. 99.99M R-21 EMC 2012 23-01-2012 3 of 41
ELETECH S.r.l. Via Garcia Lorca 29 23871 Lomagna (LC) Italy Tel. 0039.039.99340.1 Fax. 0039.039.9991289 e-mail: [email protected] - http://eletechsrl.it
2. General condition
Objective The purpose of this tests, which are described in the present report, is to verify the conformity of
Equipment Under Test (E.U.T.) to the electromagnetic compatibility directive 2004/108/EC using harmonised standards.
Testing location
ELETECH S.r.l.
Via Garcia Lorca 29 23871 Lomagna (LC) Italy Department: Test Lab Centre
A company of Elemaster Group S.p.A.
Tested by
Mr. Casiraghi Marco
Witness to the test ----
Environment condition
Average values
Ambient temperature 15° - 35° 21°C
Humidity 25% - 75% 52% UR
Pressure 860 mbar - 1080 mbar 1010 mbar
Constructor Product Report reference Date of test report Page
A.S. Distribuzione S.r.l. 99.99M R-21 EMC 2012 23-01-2012 4 of 41
ELETECH S.r.l. Via Garcia Lorca 29 23871 Lomagna (LC) Italy Tel. 0039.039.99340.1 Fax. 0039.039.9991289 e-mail: [email protected] - http://eletechsrl.it
3. Equipment under test
Description The 99.99M is a Nebulizer Disinfectant for Surfaces.
The E.U.T. contains an electronic circuit of control with oscillator frequency lower than 15 MHz. It is used for domestic, commercial and light industrial environmental.
Type
99.99M
Identification sample tested
120001SAM00.00
Identification HW of E.U.T.
----
Identification SW of E.U.T. ----
Equipment classification Household appliances
Installation environment
Domestic, commercial and light industrial
Classification for RF emission test
EN 55014-1 Floor-standing equipment
Classification for RF immunity test
EN 55014-2 Reference 4 Apparatus of category II
Floor-standing equipment
Position of use Wall
Size (mm)
400 x 500 h 500
Constructor Product Report reference Date of test report Page
A.S. Distribuzione S.r.l. 99.99M R-21 EMC 2012 23-01-2012 5 of 41
ELETECH S.r.l. Via Garcia Lorca 29 23871 Lomagna (LC) Italy Tel. 0039.039.99340.1 Fax. 0039.039.9991289 e-mail: [email protected] - http://eletechsrl.it
3. Equipment under test
Constructor Product Report reference Date of test report Page
A.S. Distribuzione S.r.l. 99.99M R-21 EMC 2012 23-01-2012 6 of 41
ELETECH S.r.l. Via Garcia Lorca 29 23871 Lomagna (LC) Italy Tel. 0039.039.99340.1 Fax. 0039.039.9991289 e-mail: [email protected] - http://eletechsrl.it
4. Test condition
Set up during the test
Equipment Used During Test
Use Product Type Manufacturer Model Comments
E.U.T. Nebulizer Disinfectant for Surfaces
A.S. Distribuzione S.r.l.
99.99M ----
E.U.T.= Equipment Under Test AE= Auxiliary equipment
Rating
Mode Voltage (V)
Current (A)
Power (W)
Frequency (Hz)
Phase Comments
Rated 230 5 1000 50 1 Class 1 with earth
Enclosure
A.C. power supply
99.99M
Constructor Product Report reference Date of test report Page
A.S. Distribuzione S.r.l. 99.99M R-21 EMC 2012 23-01-2012 7 of 41
ELETECH S.r.l. Via Garcia Lorca 29 23871 Lomagna (LC) Italy Tel. 0039.039.99340.1 Fax. 0039.039.9991289 e-mail: [email protected] - http://eletechsrl.it
4. Test condition
Identification of Ports
Port # Name Type Cable
length > 3m
Shielded
Cable
Comments
1 Enclosure - - - Metallic and plastic structure
2 A.C. power supply
AC NO NO Cable 3 wire length 150 cm
AC= AC power port DC= DC power port
I/O= Signal Input or Output Port TP= Telecommunication Port
EUT Operation Mode
Mode # Description
1 Operation continuous of E.U.T.
2 Switch ON and operation continuous, for 24 measurements, Annex B EN 61000-3-3
EUT Configuration Mode
Mode # Description
1 Input power supply 230V
Requested performance for immunity test
The E.U.T. must continue to function (criterion A).
Control method for immunity test During the immunity test check:
• Nebulization
• Timer
Performance criteria of reference standard for immunity test EN 55014-2 reference 6
Generic performance criteria
Criterion A During testing, normal performance within the specification limits.
Criterion B During testing, temporary degradation, or loss of function or performance which is self-recovering.
Criterion C During testing, temporary degradation, or loss of function or performance which requires
operator intervention or system reset occurs.
Constructor Product Report reference Date of test report Page
A.S. Distribuzione S.r.l. 99.99M R-21 EMC 2012 23-01-2012 8 of 41
ELETECH S.r.l. Via Garcia Lorca 29 23871 Lomagna (LC) Italy Tel. 0039.039.99340.1 Fax. 0039.039.9991289 e-mail: [email protected] - http://eletechsrl.it
5. Reference standard
Standard Year Title
EN 55014-1
A1
2006
2009
Electromagnetic compatibility. Requirements for household appliances,
electric tools and similar apparatus. Part 1 : Emission. Product family standard.
EN 55014-2 A1
A2
1997 2001
2008
Electromagnetic compatibility. Requirements for household appliances, electric tools and similar apparatus.
Part 2 : Immunity. Product family standard.
EN 55016-2-3 2006 Specification for radio disturbance and immunity measuring apparatus
and methods - Part 2-3: Methods of measurement of disturbances and immunity –
Radiated disturbance measurements
EN 61000-3-2
A1 A2
2006
2009 2009
Electromagnetic compatibility (EMC)
Part 3-2: Limits Limits for harmonic current emission (equipment input current up to
and including 16 A per phase).
EN 61000-3-3 2008 Electromagnetic compatibility (EMC)
Part 3-3: Limits Limitation of voltage changes, voltage fluctuations and flicker in public
low-voltage supply systems, for equipment with rated current <= 16 A
per phase and not subject to conditional connection.
EN 61000-4-2
2009 Electromagnetic compatibility. Part 4: Testing and measuring
techniques. Section 2: Electrostatic discharge immunity test.
EN 61000-4-3 A1
2006 2008
Electromagnetic compatibility. Part 4: Testing and measuring techniques. Section 3: Radiated, radio-frequency, electromagnetic field
- Immunity test
EN 61000-4-4
A1
2004
2010
Electromagnetic compatibility. Part 4: Testing and measuring
techniques. Section 4: Electrical fast transient burst immunity test
EN 61000-4-5 2006 Electromagnetic compatibility. Part 4: Testing and measuring
techniques. Section 5: Surge immunity test
EN 61000-4-6 2009 Electromagnetic compatibility. Part 4: Testing and measuring
techniques. Section 6: Immunity to conducted disturbance, induced by radio-frequency fields.
EN 61000-4-11 2004 Electromagnetic compatibility. Part 4: Testing and measuring techniques. Section 11: Voltage dips, short interruptions and voltage
variations immunity test.
Constructor Product Report reference Date of test report Page
A.S. Distribuzione S.r.l. 99.99M R-21 EMC 2012 23-01-2012 9 of 41
ELETECH S.r.l. Via Garcia Lorca 29 23871 Lomagna (LC) Italy Tel. 0039.039.99340.1 Fax. 0039.039.9991289 e-mail: [email protected] - http://eletechsrl.it
6. Instrument
Calibration instrument
Description Model Serial number Manufacturer Due date
ALI014 Power Supply PAS5000 A182601-01096 Spitzenberger+Spies 15/07/2012
AMP001 Amplifier 75A250 19666 Amplifier Research 15/07/2012 AMP002 Amplifier 100W1000M1 18650 Amplifier Research 15/07/2012 AMP003 Amplifier 30S1G3 300786 Amplifier Research 15/07/2012 AMP004 Amplifier 150A400 0330804 Amplifier Research 15/07/2012 CAM006 Semi Anechoic Chamber 3mSAC B83117-S20-X435 Albatross Projects 02/03/2014
GDF001 Signal generator HP33120A US36010500 HP 15/07/2012 GEN001 Dips generator PFS500 0296-04 EM Test 15/07/2012 GEN004 Surge generator VCS500 0995-03 EM Test 15/07/2012 GEN005 Signal generator SML03 100162 Rohde & Schwarz 15/07/2012 GEN006 Burst generator EFT 500 M4 V0712102348 EM Test 15/07/2012 GEN007 Signal generator SyCore PC/104 A3986 12/0 0507 Spitzenberger+Spies 15/07/2012 GEN008 ESD generator ESD30N V0930105020 EM Test 15/07/2012 IGR001 Humidity sensor Igrometro da parete 0 Johnson Controls 15/07/2012 MDC001 Field probe PM2002 26698 Amplifier Research 03/08/2012
MDC002 Laser Probe Interface FI7000 0332975
S/N Kit: 0333300 Amplifier Research 03/08/2012
MDC003 Laser powered field probe FL7006 Start Probe 2
100kHz - 6GHz 0332632
S/N Kit: 0333300 Amplifier Research 03/08/2012
PAS001 Coupling / Decoupling CDN M1 12039 MEB 15/07/2012 PAS002 Coupling / Decoupling CDN M2 12096 MEB 15/07/2012 PAS003 Coupling / Decoupling CDN M3 12859 MEB 15/07/2012 PAS004 Coupling / Decoupling CDN M4 00265 Eletech 15/07/2012 PAS005 Coupling / Decoupling CDN M5 00266 Eletech 15/07/2012 PAS006 Unidirectional coupling DC7144 300678 Amplifier Research 15/07/2012 PAS009 Antenna 3115 9005-3475 EMCO 26/07/2013
PAS010 LISN - Artificial mains
network ESH2-Z5 830364/008 Rohde & Schwarz
15/07/2012
PAS011 LISN ESH3-Z6 833772-010 Rohde & Schwarz 15/07/2012 PAS012 LISN ESH3-Z6 833772-011 Rohde & Schwarz 15/07/2012 PAS013 LISN ESH3-Z6 833772-009 Rohde & Schwarz 15/07/2012 PAS014 Absorbing clamp MDS 21 830409/013 Rohde & Schwarz 15/07/2012 PAS015 Burst clamp 1 METRO 00438 EM Test 15/07/2012 PAS016 RF clamp F-203I 229 FCC 04/08/2013
PAS018 Antenna Loop 2 METRI 5134 Teseo 15/07/2012 PAS020 Induction coil 50Hz 1 METRO - Eletech 15/07/2012 PAS021 Attenuator Attenuatore 6dB - TESEO 15/07/2012 PAS022 Unidirectional coupling DC6180 19593 Amplifier Research 15/07/2012 PAS023 Reference impedence IEC 725 00355 Eletech 15/07/2012 PAS024 Coupling CDN-S1 - Eletech 15/07/2012 PAS025 Coupling CDN-S1 - Eletech 15/07/2012
PAS026 Coupling / Decoupling
network for surge CDN-S 1000-4-5 - -
15/07/2012
PAS028 Antenna - Trilog Super VULB 9161SE
(25MHz - 2GHz) 9161-4084
Schwarzbeck Mess - Elektronik
03/08/2012
PAS032 Attenuator 3dB 6803.17.AC
Per Emissione Radiata - Huber+Suhner
15/07/2012
PAS034 Attenuator 6N10W - 30dB 6N10W-30 D.S.P.M.
Telecomunicazioni 15/07/2012
PAS035 Attenuator 6N - 10dB 6N10 D.S.P.M.
Telecomunicazioni 15/07/2012
PAS036 Unidirectional coupling C1795-13 38624 Werlatone 15/07/2012
Constructor Product Report reference Date of test report Page
A.S. Distribuzione S.r.l. 99.99M R-21 EMC 2012 23-01-2012 10 of 41
ELETECH S.r.l. Via Garcia Lorca 29 23871 Lomagna (LC) Italy Tel. 0039.039.99340.1 Fax. 0039.039.9991289 e-mail: [email protected] - http://eletechsrl.it
6. Instrument
Calibration instrument
Description Model Serial number Manufacturer Due date
PAS037 Attenuator 6dB 6806.17.AC
- Huber+Suhner
15/07/2012
PAS039 Coupling / Decoupling
network for burst CDN-B 1000-4-4 - -
15/07/2012
PAS040 Coupling 0,47uF+ 40 ohm
for surge CDN-C 1000-4-5 - Eletech
15/07/2012
PAS041 Decoupling for surge CDN-C 1000-4-5 - Eletech 15/07/2012
PAS042 ISN for emission on LAN
cable
NTFM 8158 ISN CAT6 - 8 wire
150kHz - 30MHz 8158-0006
Schwarzbeck Mess - Elektronik
15/07/2012
PAS043 Antenna VULP 9118 E
Log.-Per. 75MHz - 1500MHz
9118E867 Schwarzbeck
Mess - Elektronik 02/05/2013
PAS044 Unidirectional coupling DC3400A
40dB 200W 10kHz - 400MHz
0332124 Amplifier Research 15/07/2012
SON001 RF sensor + attenuator +
voltage probe ESH2-Z3 299.7810.52 Rohde & Schwarz 15/07/2012
SON004 Power head PH2000 27478 Amplifier Research 03/08/2012
SON005 Power head PH2000 301205 Amplifier Research 15/07/2012 SON007 Current Probe ESH2-Z1 830260/20 Rohde & Schwarz 15/07/2012 TER004 Temperature sensor RS9140-0000 1 Johnson Controls 15/07/2012 TES008 EMI Test Receiver ESVS 10 825892/002 Rohde & Schwarz 15/07/2012 TES009 EMI Test Receiver ESHS 10 830051/010 Rohde & Schwarz 15/07/2012
TES011 Harmonic and Flicker
measurement PMM1000 M50513 BO CONSULT
15/07/2012
TES019 Clickmeter Chase London
SW147LY 1512 - 0190
5033 Chase Electronics LTD 15/07/2012
TES020 EMI Test Receiver ESCI 7 100755 Rohde & Schwarz 15/07/2012
Constructor Product Report reference Date of test report Page
A.S. Distribuzione S.r.l. 99.99M R-21 EMC 2012 23-01-2012 11 of 41
ELETECH S.r.l. Via Garcia Lorca 29 23871 Lomagna (LC) Italy Tel. 0039.039.99340.1 Fax. 0039.039.9991289 e-mail: [email protected] - http://eletechsrl.it
7. Uncertainty
Test Reference standard Parameter Uncertainty
Measure of harmonic current
IEC 1000-3-2 Harmonic current measurement 0,11%
Voltage measurement 0,22%
EN 61000-3-2 Frequency 0,01%
Measure of mains harmonic voltage 0,06%
Measure of flickers
IEC 1000-3-3
Voltage measurement 0,22%
Frequency 0,01%
Measure of mains harmonic voltage 0,06%
EN 61000-3-3
Impedance 6,40%
Pst 4,89%
dc 0,21%
dmax, dt 0,20%
Measure of radiated emission CISPR 11 – EN 55011 Measured field (horizontal) 4.90 dB
CISPR 22 – EN 55022 Measured field (vertical) 4.93 dB
Measure of continuous emission disturbance
CISPR 11 – EN 55011
Measured voltage 2.60 dB CISPR 14 – EN 55014-1
CISPR 15 – EN 55015
CISPR 22 – EN 55022
Measure of common mode conducted emission CISPR 22 – EN 55022 Measured voltage 2.85 dB
Measure of conducted emission at terminals CISPR 14-1 – EN 55014-1
Measured voltage 2.60 dB CISPR 11 – EN 55011
Measure of disturbance power CISPR 14 – EN 55014-1 Measured power 2.78 dB
Measure of radiated electromagnetic disturbance
CISPR 15 – EN 55015 Measured field 4.12 dB
Immunity to electrostatic discharge IEC 1000-4-2 The generator meets the tolerance requirements of
EN 61000-4-2 EN 61000-4-2
Immunity to radiated immunity IEC 1000-4-3
Radiated field 2.38 dB EN 61000-4-3
Immunity to burst IEC 1000-4-4 The generator meets the tolerance requirements of
EN 61000-4-4 EN 61000-4-4
Immunity to surge IEC 1000-4-5 The generator meets the tolerance requirements of
EN 61000-4-5 EN 61000-4-5
Immunity to induced RF field IEC 1000-4-6 Applied field (CDN) 1.02 dB
EN 61000-4-6 Applied field (EM-Clamp) 2.23 dB
Immunity to magnetic field at 50Hz IEC 1000-4-8 The generator meets the tolerance requirements of
EN 61000-4-8 EN 61000-4-8
Immunity to voltage dips IEC 1000-4-11 The generator meets the tolerance requirements of
EN 61000-4-11 EN 61000-4-11
The measurement uncertainties stated in this documents are estimated as extended uncertainty obtained multiplying the standard uncertainty by the coverage factor k corresponding to a confidence level of about 95%..
Constructor Product Report reference Date of test report Page
A.S. Distribuzione S.r.l. 99.99M R-21 EMC 2012 23-01-2012 12 of 41
ELETECH S.r.l. Via Garcia Lorca 29 23871 Lomagna (LC) Italy Tel. 0039.039.99340.1 Fax. 0039.039.9991289 e-mail: [email protected] - http://eletechsrl.it
8. Result summary
Emission requirements according to
EN 55014-1: 2006 + A1: 2009
Port Test Standard / Limit Result
A.C. power supply Emission measurement: continuous disturbance
EN 55014-1 Table 1 PASS
A.C. power supply Emission measurement: discontinuous disturbance
EN 55014-1 Table 1 PASS
A.C. power supply Emission measurement: disturbance power
EN 55014-1 Table 2a PASS
A.C. power supply Emission measurement:
disturbance power
EN 55014-1 Table 2b PASS
Enclosure Radiated emission:
continuous interference
EN 55014-1 Table 3 Not applicable
Emission requirements according to EN 61000-3-2: 2006 + A1: 2009 + A2: 2009
Port Test Standard / Limit Result
A.C. power supply Emission measurement:
harmonics currents
EN 61000-3-2 Class A
PASS
Emission requirements according to
EN 61000-3-3: 2008
Port Test Standard / Limit Result
A.C. power supply Emission measurement:
voltage fluctuation and flicker
EN 61000-3-3
PASS
Constructor Product Report reference Date of test report Page
A.S. Distribuzione S.r.l. 99.99M R-21 EMC 2012 23-01-2012 13 of 41
ELETECH S.r.l. Via Garcia Lorca 29 23871 Lomagna (LC) Italy Tel. 0039.039.99340.1 Fax. 0039.039.9991289 e-mail: [email protected] - http://eletechsrl.it
8. Result summary
Immunity requirements according to
EN 55014-2: 1997 + A1: 2001 + A2: 2008
Port Test Standard / Level Compliance
criterion
Result
Enclosure Electrostatic discharge (ESD) – indirect on coupling plane with
contact discharge – direct on case with air and
contact discharge
EN 61000-4-2 ± 4 kV Cont.
± 8 kV Air
B
PASS
Enclosure Radiated electromagnetic field
80 - 1000 MHz, 80%AM (1kHz)
EN 61000-4-3
3 V/m
A
Not applicable for apparatus of category II
A.C. power
supply
Fast Transients (EFT)
Common Mode, 5/50ns, Repetition frequency 5kHz
EN 61000-4-4
± 1 kV
B
PASS
A.C. power supply
Slow transients (Surges) Pulse form 1.2/50 µs
EN 61000-4-5 ± 1 kV MD
± 2 kV MC
B
PASS
A.C. power
supply
Conducted radio frequency
150 kHz - 80 MHz, 1kHz 80% AM, 150Ω source imp.
EN 61000-4-6
3 V
A
Not applicable for apparatus of category II
A.C. power supply
Conducted radio frequency 150 kHz - 230 MHz, 1kHz 80%
AM, 150Ω source imp.
EN 61000-4-6 3 V
A
PASS
A.C. power
supply
Voltage interruption
Test level in % Ut
EN 61000-4-11
0% 10ms
B
PASS
A.C. power
supply
Voltage interruption
Test level in % Ut
EN 61000-4-11
40% 200ms
C
PASS
A.C. power
supply
Voltage interruption
Test level in % Ut
EN 61000-4-11
70% 500ms
C
PASS
Constructor Product Report reference Date of test report Page
A.S. Distribuzione S.r.l. 99.99M R-21 EMC 2012 23-01-2012 14 of 41
ELETECH S.r.l. Via Garcia Lorca 29 23871 Lomagna (LC) Italy Tel. 0039.039.99340.1 Fax. 0039.039.9991289 e-mail: [email protected] - http://eletechsrl.it
9.1. Emission measurement: continuous disturbance
Test Measurement of mains terminal disturbance. Continuous disturbance
Reference standard EN 55014-1 Reference 5
EUT operation mode # 1
EUT configuration mode # 1
Port A.C. power supply
Verdict
COMPLIANT
Limits table 1
Frequency band (MHz) Quasi-peak (dB µV) Average (dB µV)
0.15 - 0.5 66 - 56 59 - 46
0.5 - 5 56 46
5 - 30 60 50
Test equipment
Equipment Model Manufacturer Serial number
Shielded chamber Siemens
Receiver ESHS 10 R&S 830051/010
Artificial main network ESH2-Z5 R&S 830364/008
Constructor Product Report reference Date of test report Page
A.S. Distribuzione S.r.l. 99.99M R-21 EMC 2012 23-01-2012 15 of 41
ELETECH S.r.l. Via Garcia Lorca 29 23871 Lomagna (LC) Italy Tel. 0039.039.99340.1 Fax. 0039.039.9991289 e-mail: [email protected] - http://eletechsrl.it
9.1. Emission measurement: continuous disturbance ELETECH S.r.l. Conducted emission EUT: 99.99M Manufacturer: A.S. DISTRIBUZIONE Operating Condition: Continuous operation Test Site: Shielded chamber Operator: Casiraghi Test Specification: EN 55014-1 Comment: New EMI Filter 11-01-2012 SCAN TABLE: "ET QP Voltage + 6dB" Short Description: EN 55022 Voltage pr e Start Stop Step Detector Meas. IF Transducer Frequency Frequency Width Time Bandw. 150.0 kHz 30.0 MHz 8.0 kHz QuasiPeak 1.0 s 10 kHz Att. 6dB Average
-10
0
10
20
30
40
50
60
70
Level [dBµV]
150k 300k 500k 1M 2M 3M 5M 7M 10M 30MFrequency [Hz]
x x x
x
x MES 120001b_fin MES 120001b_pre MES 120001b_pre2 LIM EN 55014 V QP Voltage QPLIM EN 55014 V AV Voltage AV
Constructor Product Report reference Date of test report Page
A.S. Distribuzione S.r.l. 99.99M R-21 EMC 2012 23-01-2012 16 of 41
ELETECH S.r.l. Via Garcia Lorca 29 23871 Lomagna (LC) Italy Tel. 0039.039.99340.1 Fax. 0039.039.9991289 e-mail: [email protected] - http://eletechsrl.it
9.1. Emission measurement: continuous disturbance
MEASUREMENT RESULT: "120001b_fin" 02/01/80 0.18 Frequency Level Transd Limit Margin Detec tor Line PE MHz dBµV dB dBµV dB 0.190000 53.60 6.0 64 10.4 QP L1 GND 0.286000 52.30 6.0 61 8.3 QP L1 GND 0.318000 51.20 6.0 60 8.6 QP L1 GND 0.454000 40.10 6.0 57 16.7 QP L1 GND
Constructor Product Report reference Date of test report Page
A.S. Distribuzione S.r.l. 99.99M R-21 EMC 2012 23-01-2012 17 of 41
ELETECH S.r.l. Via Garcia Lorca 29 23871 Lomagna (LC) Italy Tel. 0039.039.99340.1 Fax. 0039.039.9991289 e-mail: [email protected] - http://eletechsrl.it
9.2. Emission measurement: discontinuous disturbance
Test Measurement of mains terminal disturbance.
Discontinuous disturbance
Reference standard EN 55014-1
EUT operation mode # 1
EUT configuration mode # 1
Port A.C. power supply
Verdict
COMPLIANT
Limits table 1
Frequency band (MHz) Quasi-peak (dB µV) Average (dB µV)
0.15 - 0.5 66 - 56 59 - 46
0.5 - 5 56 46
5 - 30 60 50
Test equipment
Equipment Model Manufacturer Serial number
Shielded chamber Siemens
Clickmeter DIA 1512 Chase 5107
Receiver ESHS 10 R&S 83005/010
Artificial main network ESH2-Z5 R&S 830364/008
Constructor Product Report reference Date of test report Page
A.S. Distribuzione S.r.l. 99.99M R-21 EMC 2012 23-01-2012 18 of 41
ELETECH S.r.l. Via Garcia Lorca 29 23871 Lomagna (LC) Italy Tel. 0039.039.99340.1 Fax. 0039.039.9991289 e-mail: [email protected] - http://eletechsrl.it
9.2. Emission measurement: discontinuous disturbance
Frequency
(MHz)
f 0.15 0.50 1.4 30
Continuous limit (dBµV)
L 66 56 56 60
Time T 120 120 120 120 Counted click (N) (short <= 10ms )
NA 0 0 0 0
Counted click (N) (short > 20ms )
NA 0 0 0 0
Counted click
(N) (long)
NB 0 0 0 0
Counted click
(N)
N1(1)
Click frequency (N/ min)
N(2)
Continuous d(3)
More than 2 clicks in 2 sec
New limit
(dBµV)
LQ(4) - - - -
Number of
clicks over LQ
(short)
NA
Number of
clicks over LQ (long)
NB
Number of
clicks over LQ
N2
Percentage (%)
N2/n1(5)
Final result Compliant Compliant Compliant Compliant
(1) : minimum 40 clicks or 120 min. of testing time
(2) : K*n1/T with =0.66sec (3) : maximum acceptable limit of 0.6sec
(4) : LQ=L + 20Log (30/N) (0.2<N<30) ; LQ= L + 44(N<0.2)
(5) : n2/n1 %< (or=) 25
Constructor Product Report reference Date of test report Page
A.S. Distribuzione S.r.l. 99.99M R-21 EMC 2012 23-01-2012 19 of 41
ELETECH S.r.l. Via Garcia Lorca 29 23871 Lomagna (LC) Italy Tel. 0039.039.99340.1 Fax. 0039.039.9991289 e-mail: [email protected] - http://eletechsrl.it
9.3. Emission measurement: disturbance power
Test Measurement of mains terminal disturbance.
Disturbance power
Reference standard EN 55014-1 Reference 6
EUT operation mode # 1
EUT configuration mode # 1
Port A.C. power supply
Verdict
COMPLIANT
Limits table 2
Frequency band (MHz) Quasi-peak (dB pW) Average (dB pW)
30 - 300 45 - 55 35 - 45
Test equipment
Equipment Model Manufacturer Serial number
Semi Anechoic Chamber 3m SAC Albatros Projects
Clamp MDS 21 R&S 830409/013
Receiver ESVS 10 R&S 825892/002
Constructor Product Report reference Date of test report Page
A.S. Distribuzione S.r.l. 99.99M R-21 EMC 2012 23-01-2012 20 of 41
ELETECH S.r.l. Via Garcia Lorca 29 23871 Lomagna (LC) Italy Tel. 0039.039.99340.1 Fax. 0039.039.9991289 e-mail: [email protected] - http://eletechsrl.it
9.3. Emission measurement: disturbance power
Constructor Product Report reference Date of test report Page
A.S. Distribuzione S.r.l. 99.99M R-21 EMC 2012 23-01-2012 21 of 41
ELETECH S.r.l. Via Garcia Lorca 29 23871 Lomagna (LC) Italy Tel. 0039.039.99340.1 Fax. 0039.039.9991289 e-mail: [email protected] - http://eletechsrl.it
9.3. Emission measurement: disturbance power
Constructor Product Report reference Date of test report Page
A.S. Distribuzione S.r.l. 99.99M R-21 EMC 2012 23-01-2012 22 of 41
ELETECH S.r.l. Via Garcia Lorca 29 23871 Lomagna (LC) Italy Tel. 0039.039.99340.1 Fax. 0039.039.9991289 e-mail: [email protected] - http://eletechsrl.it
9.3. Emission measurement: disturbance power
Constructor Product Report reference Date of test report Page
A.S. Distribuzione S.r.l. 99.99M R-21 EMC 2012 23-01-2012 23 of 41
ELETECH S.r.l. Via Garcia Lorca 29 23871 Lomagna (LC) Italy Tel. 0039.039.99340.1 Fax. 0039.039.9991289 e-mail: [email protected] - http://eletechsrl.it
9.4. Emission measurement: electromagnetic radiation disturbance
Test Radiated emission: continuous interference
Reference standard EN 55014-1 + A1 Reference 9 EN 55016-2-3
EUT operation mode # 1
EUT configuration mode # 1
Port Enclosure
Verdict
NOT APPLICABLE
Limit table 3
Frequency band (MHz) Quasi-peak (dB µV/m)
30 - 230 30
> 230 - 1000 37
The limits are increased by a factor of 10 dB for the measuring distance of 3 m
Limit table 2a
Frequency band (MHz) Quasi-peak (dB pW)
30 - 300 45 - 55
Limit table 2b
Frequency range Margin
200 - 300 0 to 10 dB
Test equipment
Equipment Model Manufacturer Serial number
Semi Anechoic Chamber 3mSAC Albatros Project
Receiver ESCI 7 R&S 100755
Antenna VULB 9161 SE SCHWARZBECK 9161-4084
In according to EN 55014-1 reference 4.1.2.3.2, the measure in the frequency range from 300MHz to 1000MHz are not applicable because the EUT is comply at following condition:
1) All emission readings from the equipment under test shall be lower than the applicable limits
(Table 2a) reduced by the margin (Table 2b);
2) The maximum clock frequency shall be less than 30 MHz.
Constructor Product Report reference Date of test report Page
A.S. Distribuzione S.r.l. 99.99M R-21 EMC 2012 23-01-2012 24 of 41
ELETECH S.r.l. Via Garcia Lorca 29 23871 Lomagna (LC) Italy Tel. 0039.039.99340.1 Fax. 0039.039.9991289 e-mail: [email protected] - http://eletechsrl.it
9.5. Emission measurement: harmonics currents
Test Measurement of harmonics current injected into public supply system.
Reference standard EN 61000-3-2
Reference 6 Class A equipment
EUT operation mode # 1
EUT configuration mode # 1
Port A.C. power supply
Verdict
COMPLIANT
Limits table 1
Number Harmonics Max harmonics current (A)
Odd harmonics
3 2,3
5 1,14
7 0,77
9 0,4
11 0,33
13 0,21
15 <= n <= 39 0,15 x (15/n)
Even harmonics
2 1,08
4 0,43
6 0,30
8 <= n <= 40 0,8 x (8/n)
Test equipment
Equipment Model Manufacturer Serial number
Harmonics analyser and
flickermeter
B10 / PMM1000 PMM M50513
A.C. Power PAS 5000 SPITZENBERGER A182601/01096
Constructor Product Report reference Date of test report Page
A.S. Distribuzione S.r.l. 99.99M R-21 EMC 2012 23-01-2012 25 of 41
ELETECH S.r.l. Via Garcia Lorca 29 23871 Lomagna (LC) Italy Tel. 0039.039.99340.1 Fax. 0039.039.9991289 e-mail: [email protected] - http://eletechsrl.it
9.5. Emission measurement: harmonics currents
EUT operation mode #1 (Harmonics current)
Name: Casiraghi Serial no: ----
Department: Test Lab Centre Operating modes: Normal operation
Company: ELETECH S.r.l. Comment1:
Test report no: 120001 Comment2:
Device: Sterilizzatore di ambient Comment3:
Specimen: EN 61000-3-2 Comment4:
Manufacturer: A.S. DISTR. LA FUCINA Date: 12.01.2012
Type: 99.99 M Test date: 12.01.2012
Maximum RMS current and corresponding values in timewindow 4:
Voltage:
Current:
Power:
Power factor:
Test conditions:
229.81 Vrms
4.816 Arms
1041.5 W
0.941
EN 61000-3-2:2006 + A1:2009 + A2:2009, f=50 Hz, Phase=L1, Range=20.00 A
Time window=10/12 (200ms), Grouping (>2nd harm.)=on
No Ztest selected
harmonic cur. < 0.6 % of I or < 5 mA are NOT DISREGARD for calc. of THD, THC, POHC, PWHD
P1=1041.6 W
CosPhi1: 0.973
THD=0.05 %
THD=26.43 %
1106.8 VA
THV=0.116 V
THC=1.231 A
POHV=0.008 V
POHC=0.020 A
PWHD=0.03 %
PWHD=3.76 %
Entire measurement (30.000 s = 150 time window(s)) Worst 2.5 min Average PASS
FAIL
Ha Maximum Window EN61000-3-2
Class A
Margin
in MaxWin
100 to
150%
150 to
200%
Ex-
ceeded
100 to
150%
Ex-
ceeded
Value Ex-
ceeded
DC 0.0462 A 46 -.- - - - - - - . - 0 0 0 n.e. n.e. 0.0357 A 0 X
1 4.6561 A 4 -.- - - - - - - . - 0 0 0 n.e. n.e. 4.4904 A 0 X
2 0.0141 A 149 1.0800 A -98.7 % 0 0 0 n.e. n.e. 0.0104 A 0 X
3 1.2352 A 52 2.3000 A -46.3 % 0 0 0 n.e. n.e. 1.2305 A 0 X
4 0.0121 A 103 0.4300 A -97.2 % 0 0 0 n.e. n.e. 0.0107 A 0 X
5 0.0721 A 149 1.1400 A -93.7 % 0 0 0 n.e. n.e. 0.0615 A 0 X
6 0.0172 A 5 0.3000 A -94.3 % 0 0 0 n.e. n.e. 0.0137 A 0 X
7 0.0905 A 150 0.7700 A -88.2 % 0 0 0 n.e. n.e. 0.0887 A 0 X
8 0.0159 A 133 0.2300 A -93.1 % 0 0 0 n.e. n.e. 0.0118 A 0 X
9 0.0198 A 11 0.4000 A -95.1 % 0 0 0 n.e. n.e. 0.0174 A 0 X
10 0.0130 A 139 0.1840 A -92.9 % 0 0 0 n.e. n.e. 0.0097 A 0 X
11 0.0181 A 149 0.3300 A -94.5 % 0 0 0 n.e. n.e. 0.0156 A 0 X
12 0.0496 A 87 0.1533 A -67.7 % 0 0 0 n.e. n.e. 0.0427 A 0 X
13 0.0141 A 122 0.2100 A -93.3 % 0 0 0 n.e. n.e. 0.0107 A 0 X
14 0.0438 A 90 0.1314 A -66.7 % 0 0 0 n.e. n.e. 0.0372 A 0 X
15 0.0136 A 125 0.1500 A -90.9 % 0 0 0 n.e. n.e. 0.0093 A 0 X
16 0.0100 A 41 0.1150 A -91.3 % 0 0 0 n.e. n.e. 0.0086 A 0 X
17 0.0075 A 1 0.1324 A -94.4 % 0 0 0 n.e. n.e. 0.0056 A 0 X
18 0.0058 A 147 0.1022 A -94.4 % 0 0 0 n.e. n.e. 0.0046 A 0 X
19 0.0073 A 73 0.1184 A -93.9 % 0 0 0 n.e. n.e. 0.0058 A 0 X
20 0.0047 A 136 0.0920 A -94.9 % 0 0 0 n.e. n.e. 0.0038 A 0 X
21 0.0111 A 36 0.1071 A -89.6 % 0 0 0 n.e. n.e. 0.0078 A 0 X
22 0.0044 A 106 0.0836 A -94.8 % 0 0 0 n.e. n.e. 0.0036 A 0 X
23 0.0078 A 31 0.0978 A -92.0 % 0 0 0 n.e. n.e. 0.0067 A 0 X
24 0.0061 A 1 0.0767 A -92.0 % 0 0 0 n.e. n.e. 0.0040 A 0 X
25 0.0238 A 150 0.0900 A -73.6 % 0 0 0 n.e. n.e. 0.0154 A 0 X
26 0.0056 A 1 0.0708 A -92.0 % 0 0 0 n.e. n.e. 0.0034 A 0 X
27 0.0284 A 86 0.0833 A -65.9 % 0 0 0 n.e. n.e. 0.0213 A 0 X
28 0.0057 A 109 0.0657 A -91.3 % 0 0 0 n.e. n.e. 0.0046 A 0 X
29 0.0053 A 50 0.0776 A -93.1 % 0 0 0 n.e. n.e. 0.0048 A 0 X
30 0.0052 A 14 0.0613 A -91.5 % 0 0 0 n.e. n.e. 0.0037 A 0 X
31 0.0039 A 130 0.0726 A -94.6 % 0 0 0 n.e. n.e. 0.0030 A 0 X
32 0.0079 A 34 0.0575 A -86.3 % 0 0 0 n.e. n.e. 0.0060 A 0 X
33 0.0034 A 105 0.0682 A -95.0 % 0 0 0 n.e. n.e. 0.0029 A 0 X
34 0.0082 A 23 0.0541 A -84.8 % 0 0 0 n.e. n.e. 0.0049 A 0 X
35 0.0029 A 95 0.0643 A -95.5 % 0 0 0 n.e. n.e. 0.0024 A 0 X
36 0.0056 A 90 0.0511 A -89.1 % 0 0 0 n.e. n.e. 0.0042 A 0 X
37 0.0034 A 43 0.0608 A -94.4 % 0 0 0 n.e. n.e. 0.0030 A 0 X
38 0.0181 A 87 0.0484 A -62.6 % 0 0 0 n.e. n.e. 0.0123 A 0 X
39 0.0147 A 36 0.0577 A -74.6 % 0 0 0 n.e. n.e. 0.0078 A 0 X
40 0.0119 A 148 0.0460 A -74.2 % 0 0 0 n.e. n.e. 0.0075 A 0 X
HARMONIC ANALYSIS: Test PASS
Tobs = entire measurement; POHC: avg=0.03 A, limits=0.25 A
Iavg=4.658 Arms
Tested with SPS EMC 3.0.4 / None by Spitzenberger & Spies GmbH & Co. KG, Schmidstr. 32-34, 94234 Viechtach, Germany, 12.01.2012
average value < 0.6 % of Iavg or < 5 mA
Constructor Product Report reference Date of test report Page
A.S. Distribuzione S.r.l. 99.99M R-21 EMC 2012 23-01-2012 26 of 41
ELETECH S.r.l. Via Garcia Lorca 29 23871 Lomagna (LC) Italy Tel. 0039.039.99340.1 Fax. 0039.039.9991289 e-mail: [email protected] - http://eletechsrl.it
9.5. Emission measurement: harmonics currents
EUT operation mode #1 (Harmonics voltage)
Name: Casiraghi Serial no: ----
Department: Test Lab Centre Operating modes: Normal operation
Company: ELETECH S.r.l. Comment1:
Test report no: 120001 Comment2:
Device: Sterilizzatore di ambient Comment3:
Specimen: EN 61000-3-2 Comment4:
Manufacturer: A.S. DISTR. LA FUCINA Date: 12.01.2012
Type: 99.99 M Test date: 12.01.2012
Maximum RMS current and corresponding values in timewindow 4:
Voltage:
Current:
Power:
Power factor:
Test conditions:
229.81 Vrms
4.816 Arms
1041.5 W
0.941
EN 61000-3-2:2006 + A1:2009 + A2:2009, f=50 Hz, Phase=L1, Range=20.00 A
Time window=10/12 (200ms), Grouping (>2nd harm.)=on
No Ztest selected
harmonic cur. < 0.6 % of I or < 5 mA are NOT DISREGARD for calc. of THD, THC, POHC, PWHD
P1=1041.6 W
CosPhi1: 0.973
THD=0.05 %
THD=26.43 %
1106.8 VA
THV=0.116 V
THC=1.231 A
POHV=0.008 V
POHC=0.020 A
PWHD=0.03 %
PWHD=3.76 %
Entire measurement (30.000 s = 150 time window(s)) Worst 2.5 min Average PASS
FAIL
Ha Maximum Window EN61000-3-2
Voltages
Margin
in MaxWin
100 to
150%
Ex-
ceeded
100 to
150%
Ex-
ceeded
Value Ex-
ceeded
DC 0.0097 V 72 -.- - - - - - - . - - - - 0 n.e. n.e. 0.0035 V 0 X
1 229.8466 V 145 -.- - - - - - - . - - - - 0 n.e. n.e. 229.8320 V 0 X
2 0.0288 V 145 fluctuating -93.7 % - - - 0 n.e. n.e. 0.0218 V 0 X
3 0.1190 V 149 fluctuating -94.2 % - - - 0 n.e. n.e. 0.1125 V 0 X
4 0.0084 V 150 fluctuating -98.2 % - - - 0 n.e. n.e. 0.0065 V 0 X
5 0.0106 V 150 fluctuating -98.9 % - - - 0 n.e. n.e. 0.0078 V 0 X
6 0.0064 V 147 fluctuating -98.6 % - - - 0 n.e. n.e. 0.0040 V 0 X
7 0.0163 V 131 fluctuating -97.6 % - - - 0 n.e. n.e. 0.0129 V 0 X
8 0.0058 V 147 fluctuating -98.7 % - - - 0 n.e. n.e. 0.0040 V 0 X
9 0.0037 V 145 fluctuating -99.2 % - - - 0 n.e. n.e. 0.0024 V 0 X
10 0.0053 V 99 fluctuating -98.8 % - - - 0 n.e. n.e. 0.0041 V 0 X
11 0.0032 V 30 fluctuating -98.6 % - - - 0 n.e. n.e. 0.0024 V 0 X
12 0.0061 V 148 fluctuating -97.3 % - - - 0 n.e. n.e. 0.0038 V 0 X
13 0.0028 V 115 fluctuating -98.8 % - - - 0 n.e. n.e. 0.0014 V 0 X
14 0.0053 V 102 fluctuating -97.7 % - - - 0 n.e. n.e. 0.0032 V 0 X
15 0.0053 V 149 fluctuating -97.7 % - - - 0 n.e. n.e. 0.0041 V 0 X
16 0.0026 V 102 fluctuating -98.9 % - - - 0 n.e. n.e. 0.0017 V 0 X
17 0.0038 V 143 fluctuating -98.3 % - - - 0 n.e. n.e. 0.0030 V 0 X
18 0.0017 V 139 fluctuating -99.2 % - - - 0 n.e. n.e. 0.0011 V 0 X
19 0.0056 V 149 fluctuating -97.6 % - - - 0 n.e. n.e. 0.0045 V 0 X
20 0.0017 V 146 fluctuating -99.3 % - - - 0 n.e. n.e. 0.0010 V 0 X
21 0.0031 V 150 fluctuating -98.7 % - - - 0 n.e. n.e. 0.0014 V 0 X
22 0.0019 V 144 fluctuating -99.2 % - - - 0 n.e. n.e. 0.0013 V 0 X
23 0.0024 V 95 fluctuating -99.0 % - - - 0 n.e. n.e. 0.0017 V 0 X
24 0.0023 V 36 fluctuating -99.0 % - - - 0 n.e. n.e. 0.0015 V 0 X
25 0.0051 V 145 fluctuating -97.8 % - - - 0 n.e. n.e. 0.0023 V 0 X
26 0.0013 V 150 fluctuating -99.4 % - - - 0 n.e. n.e. 0.0008 V 0 X
27 0.0044 V 130 fluctuating -98.1 % - - - 0 n.e. n.e. 0.0021 V 0 X
28 0.0013 V 34 fluctuating -99.4 % - - - 0 n.e. n.e. 0.0007 V 0 X
29 0.0022 V 139 fluctuating -99.0 % - - - 0 n.e. n.e. 0.0009 V 0 X
30 0.0018 V 18 fluctuating -99.2 % - - - 0 n.e. n.e. 0.0009 V 0 X
31 0.0033 V 2 fluctuating -98.5 % - - - 0 n.e. n.e. 0.0026 V 0 X
32 0.0018 V 24 fluctuating -99.2 % - - - 0 n.e. n.e. 0.0008 V 0 X
33 0.0031 V 123 fluctuating -98.6 % - - - 0 n.e. n.e. 0.0022 V 0 X
34 0.0015 V 15 fluctuating -99.3 % - - - 0 n.e. n.e. 0.0007 V 0 X
35 0.0044 V 53 fluctuating -98.1 % - - - 0 n.e. n.e. 0.0038 V 0 X
36 0.0014 V 100 fluctuating -99.4 % - - - 0 n.e. n.e. 0.0007 V 0 X
37 0.0052 V 1 fluctuating -97.7 % - - - 0 n.e. n.e. 0.0042 V 0 X
38 0.0031 V 148 fluctuating -98.7 % - - - 0 n.e. n.e. 0.0009 V 0 X
39 0.0022 V 140 fluctuating -99.0 % - - - 0 n.e. n.e. 0.0015 V 0 X
40 0.0023 V 146 fluctuating -99.0 % - - - 0 n.e. n.e. 0.0008 V 0 X
HARMONIC ANALYSIS: Test PASS
Tobs = entire measurement; POHC: avg=0.01 V, limits=0.73 V
Vavg=229.83 Vrms
Tested with SPS EMC 3.0.4 / None by Spitzenberger & Spies GmbH & Co. KG, Schmidstr. 32-34, 94234 Viechtach, Germany, 12.01.2012
Constructor Product Report reference Date of test report Page
A.S. Distribuzione S.r.l. 99.99M R-21 EMC 2012 23-01-2012 27 of 41
ELETECH S.r.l. Via Garcia Lorca 29 23871 Lomagna (LC) Italy Tel. 0039.039.99340.1 Fax. 0039.039.9991289 e-mail: [email protected] - http://eletechsrl.it
9.6. Emission measurement: voltage fluctuation and flicker
Test Measurement of voltage fluctuation and flicker injected into public
supply system.
Reference standard EN 61000-3-3
EUT operation mode # 2
EUT configuration mode # 1
Port A.C. power supply
Verdict
COMPLIANT
Limits
Condition # Measuring
time
PLT PST dt dmax dc
2 24 x 1min. - - 3,3% for
more than
500mS
7% of Ut 3,3% of Ut
Ut = power supply of E.U.T. (230V c.a.) Plt = The flicker severity evaluated over a long period (a few hours) using successive Pst values. Pst = The flicker severity evaluated over a short period (in minutes)Pst=1 is the conventional threshold of irritability. Dt = The time function of the change in the r.m.s. voltage between periods when the voltage is in a steady-state condition for at least 1 s. Dmax = The difference between maximum and minimum r.m.s. values of the voltage change characteristics. Dc = The difference between two adjacent steady-state voltage separated by at least one voltage change characteristics.
Test equipment
Equipment Model Manufacturer Serial number
Harmonics analyser and
flickermeter
B10 / PMM1000 PMM M50513
A.C. Power PAS 5000 SPITZENBERGER A182601/01096
Constructor Product Report reference Date of test report Page
A.S. Distribuzione S.r.l. 99.99M R-21 EMC 2012 23-01-2012 28 of 41
ELETECH S.r.l. Via Garcia Lorca 29 23871 Lomagna (LC) Italy Tel. 0039.039.99340.1 Fax. 0039.039.9991289 e-mail: [email protected] - http://eletechsrl.it
9.6. Emission measurement: voltage fluctuation and flicker
Name: Casiraghi Serial no: ----
Department: Test Lab Centre Operating modes: Normal operation
Company: ELETECH S.r.l. Comment1:
Test report no: 120001 Comment2:
Device: Sterilizzatore di ambient Comment3:
Specimen: EN 61000-3-2 Comment4:
Manufacturer: A.S. DISTR. LA FUCINA Date: 12.01.2012
Type: 99.99 M Test date: 12.01.2012
Test conditions: EN 61000-3-3:2008 / 229 V / 50 Hz / Phase L1 /
Obs cont. mode / Ztest (0.400+j0.250) Ohm
Time Pmax Pst Sliding Plt d(t)>3.30% [s] dmax [%] dc [%] PASS FAIL
09:48:26 - . - - - - . - - - - - . - - - - 0.090 4.692 0.956 X
09:49:22 - . - - - - . - - - - - . - - - - 0.090 4.672 - . - - - X
09:50:22 - . - - - - . - - - - - . - - - - 0.090 4.356 0.926 X
09:51:06 - . - - - - . - - - - - . - - - - 0.090 4.486 - . - - - X
09:51:46 - . - - - - . - - - - - . - - - - 0.090 4.813 - . - - - X
09:52:30 - . - - - - . - - - - - . - - - - 0.090 4.862 0.949 X
09:53:26 - . - - - - . - - - - - . - - - - 0.090 4.779 0.932 X
09:54:26 - . - - - - . - - - - - . - - - - 0.095 4.778 0.933 X
09:55:06 - . - - - - . - - - - - . - - - - 0.080 4.368 - . - - - X
09:55:54 - . - - - - . - - - - - . - - - - 0.090 4.824 - . - - - X
09:56:46 - . - - - - . - - - - - . - - - - 0.080 4.396 0.929 X
09:57:38 - . - - - - . - - - - - . - - - - 0.090 4.451 0.938 X
09:58:26 - . - - - - . - - - - - . - - - - 0.090 4.754 - . - - - X
09:59:18 - . - - - - . - - - - - . - - - - 0.080 4.416 0.940 X
10:00:10 - . - - - - . - - - - - . - - - - 0.090 4.456 0.935 X
10:00:50 - . - - - - . - - - - - . - - - - 0.090 4.538 - . - - - X
10:01:34 - . - - - - . - - - - - . - - - - 0.090 4.703 0.941 X
10:02:42 - . - - - - . - - - - - . - - - - 0.090 4.506 0.938 X
10:03:42 - . - - - - . - - - - - . - - - - 0.080 4.320 0.939 X
10:04:46 - . - - - - . - - - - - . - - - - 0.090 4.783 0.931 X
10:05:46 - . - - - - . - - - - - . - - - - 0.080 4.378 - . - - - X
10:06:26 - . - - - - . - - - - - . - - - - 0.080 4.295 0.933 X
10:07:10 - . - - - - . - - - - - . - - - - 0.080 4.327 0.927 X
10:07:46 - . - - - - . - - - - - . - - - - 0.080 4.266 - . - - - X
Limits: 1.000 0.650 0.500 7.000 3.300
Plt: 3.600905
Evaluated: dc, dmax average (4.550 %), d(t)
FLICKER: Test PASS!
Time Pmax Pst Sliding Plt d(t)>3.30% [s] dmax [%] dc [%] PASS FAIL
09:48:26 - . - - - - . - - - - - . - - - - 0.000 0.336 0.081 X
09:49:22 - . - - - - . - - - - - . - - - - 0.000 0.318 - . - - - X
09:50:22 - . - - - - . - - - - - . - - - - 0.000 0.319 - . - - - X
09:51:06 - . - - - - . - - - - - . - - - - 0.000 0.322 - . - - - X
09:51:46 - . - - - - . - - - - - . - - - - 0.000 0.340 - . - - - X
09:52:30 - . - - - - . - - - - - . - - - - 0.000 0.347 - . - - - X
09:53:26 - . - - - - . - - - - - . - - - - 0.000 0.353 - . - - - X
09:54:26 - . - - - - . - - - - - . - - - - 0.000 0.353 - . - - - X
09:55:06 - . - - - - . - - - - - . - - - - 0.000 0.353 - . - - - X
09:55:54 - . - - - - . - - - - - . - - - - 0.000 0.353 - . - - - X
09:56:46 - . - - - - . - - - - - . - - - - 0.000 0.353 - . - - - X
09:57:38 - . - - - - . - - - - - . - - - - 0.000 0.353 - . - - - X
09:58:26 - . - - - - . - - - - - . - - - - 0.000 0.353 - . - - - X
09:59:18 - . - - - - . - - - - - . - - - - 0.000 0.353 - . - - - X
10:00:10 - . - - - - . - - - - - . - - - - 0.000 0.358 - . - - - X
10:00:50 - . - - - - . - - - - - . - - - - 0.000 0.360 - . - - - X
10:01:34 - . - - - - . - - - - - . - - - - 0.000 0.360 - . - - - X
10:02:42 - . - - - - . - - - - - . - - - - 0.000 0.360 - . - - - X
10:03:42 - . - - - - . - - - - - . - - - - 0.000 0.360 - . - - - X
10:04:46 - . - - - - . - - - - - . - - - - 0.000 0.363 - . - - - X
10:05:46 - . - - - - . - - - - - . - - - - 0.000 0.363 - . - - - X
10:06:26 - . - - - - . - - - - - . - - - - 0.000 0.363 - . - - - X
10:07:10 - . - - - - . - - - - - . - - - - 0.000 0.369 - . - - - X
10:07:46 - . - - - - . - - - - - . - - - - 0.000 0.369 - . - - - X
Plt: 0.249695
Evaluated: PST <= 0.4 dmax < 20 % dmax1
FLICKER: Source test PASS!
Tested with SPS EMC 3.0.4 / None by Spitzenberger & Spies GmbH & Co. KG, Schmidstr. 32-34, 94234 Viechtach, Germany, 12.01.2012
Constructor Product Report reference Date of test report Page
A.S. Distribuzione S.r.l. 99.99M R-21 EMC 2012 23-01-2012 29 of 41
ELETECH S.r.l. Via Garcia Lorca 29 23871 Lomagna (LC) Italy Tel. 0039.039.99340.1 Fax. 0039.039.9991289 e-mail: [email protected] - http://eletechsrl.it
10.1. Immunity test: electrostatics discharge ESD
Scope To assess the performances of the appliances when they are
submitted to static electricity discharge, from operators directly, and to adjacent objects.
Reference standard EN 61000-4-2
EN 55014-2 Table 1
EUT operation mode # 1
EUT configuration mode # 1
Port Enclosure
Verdict
COMPLIANT
Test level apply (background grey)
Contact discharge Air discharge
Level Voltage level kV Level Voltage level kV
1 2 1 2
2 4 2 4
3 6 3 8
4 8 4 15
x special x special
Test equipment
Equipment Model Manufacturer Serial number
ESD generator ESD 30 EM TEST 0296-41
Set ESD generator
Method coupling Discharge electrodes 150pF + 330 ohm
Number of discharge > 10 for every point select
Repetition rate 1/second
Constructor Product Report reference Date of test report Page
A.S. Distribuzione S.r.l. 99.99M R-21 EMC 2012 23-01-2012 30 of 41
ELETECH S.r.l. Via Garcia Lorca 29 23871 Lomagna (LC) Italy Tel. 0039.039.99340.1 Fax. 0039.039.9991289 e-mail: [email protected] - http://eletechsrl.it
10.1. Immunity test: electrostatics discharge ESD
Test
Discharge points Type of discharge
Test voltage Result criterion
Remark
Enclosure, plastic parts Air ± 2kV A E.U.T. operated as intended
± 4kV A E.U.T. operated as intended
± 8kV A E.U.T. operated as intended
Enclosure VCP ± 2kV A E.U.T. operated as intended
± 4kV A E.U.T. operated as intended
± 6kV - -
Enclosure, metallic part
CONTACT ± 2kV A E.U.T. operated as intended
± 4kV A E.U.T. operated as intended
± 6kV - -
Display and keyboard Air ± 2kV A E.U.T. operated as intended
± 4kV A E.U.T. operated as intended
± 8kV A E.U.T. operated as intended
VCP= Vertical Coupling Plan HCP= Horizontal Coupling Plan
N.A.= Not Applicable
Constructor Product Report reference Date of test report Page
A.S. Distribuzione S.r.l. 99.99M R-21 EMC 2012 23-01-2012 31 of 41
ELETECH S.r.l. Via Garcia Lorca 29 23871 Lomagna (LC) Italy Tel. 0039.039.99340.1 Fax. 0039.039.9991289 e-mail: [email protected] - http://eletechsrl.it
10.2. Immunity test: radiated RF electromagnetic field
Scope To assess the performances of the appliances when they are
submitted to electromagnetic field.
Reference standard EN 61000-4-3 + A1 EN 55014-2 + A1 + A2 Table 11
EUT operation mode # 1
EUT configuration mode # 1
Port Enclosure
Verdict
NOT APPLICABLE
Test level (background grey)
Level Test field strength (V/m)
1 1
2 3
3 10
x x
Test equipment
Equipment Model Manufacturer Serial number
Semi Anechoic chamber 3mSAC Albatros Project
RF signal generator SML 03 Rohde & Schwarz 100162
Amplifier 100W1000M1 Amplifier Research 18650
Amplifier 150A400 Amplifier Research 0330804
Amplifier 30S1GS3 Amplifier Research 300786
Horn antenna 3115 Emco 9005-3475
Log-periodic antenna VULP 9118 E Schwarzbeck
Mess - Elektronik
9118E867
Set RF generator
Frequency range 80 – 1000 MHz
Modulation AM 80% 1 kHz sine-wave
Step 1%
Dwell time 3 second
Constructor Product Report reference Date of test report Page
A.S. Distribuzione S.r.l. 99.99M R-21 EMC 2012 23-01-2012 32 of 41
ELETECH S.r.l. Via Garcia Lorca 29 23871 Lomagna (LC) Italy Tel. 0039.039.99340.1 Fax. 0039.039.9991289 e-mail: [email protected] - http://eletechsrl.it
10.2. Immunity test: radiated RF electromagnetic field
Scope To assess the performances of the appliances when they are
submitted to electromagnetic field.
Reference standard EN 61000-4-3 + A1 EN 55014-2 + A1 + A2 Table 11
EUT operation mode # 1
EUT configuration mode # 1
Port Enclosure
Verdict
NOT APPLICABLE
Test level (background grey)
Level Test field strength (V/m)
1 1
2 3
3 10
x x
Test equipment
Equipment Model Manufacturer Serial number
Semi Anechoic chamber 3mSAC Albatros Project
RF signal generator SML 03 Rohde & Schwarz 100162
Amplifier 100W1000M1 Amplifier Research 18650
Amplifier 150A400 Amplifier Research 0330804
Amplifier 30S1GS3 Amplifier Research 300786
Horn antenna 3115 Emco 9005-3475
Log-periodic antenna VULP 9118 E Schwarzbeck
Mess - Elektronik
9118E867
Set RF generator
Frequency (MHz) 80, 230, 460, 690, 1000
Modulation AM 80% 1 kHz sine-wave
Step -
Dwell time 180 seconds for every frequency
Constructor Product Report reference Date of test report Page
A.S. Distribuzione S.r.l. 99.99M R-21 EMC 2012 23-01-2012 33 of 41
ELETECH S.r.l. Via Garcia Lorca 29 23871 Lomagna (LC) Italy Tel. 0039.039.99340.1 Fax. 0039.039.9991289 e-mail: [email protected] - http://eletechsrl.it
10.3. Immunity test: electrical fast transients, burst
Scope To assess the performances of the appliances when they are
submitted to repetitive electrical fast transients.
Reference standard EN 61000-4-4 + A1 EN 55014-2 + A1 + A2 Table 4
EUT operation mode # 1
EUT configuration mode # 1
Port A.C. power supply
Verdict
COMPLIANT
Test level (background grey)
Level On power supply port , ground On I/O signal, data and control
ports
Voltage peak kV Repetition rate kHz Voltage peak kV Repetition rate kHz
1 0,5 5 0,25 5 2 1 5 0,5 5 3 2 5 1 5 4 4 5 2 5 x
Test equipment
Equipment Model Manufacturer Serial number
Burst generator EFT 500M4 EM TEST V0712102348
Clamp 1 meter EM TEST
Set burst generator
Method coupling for power supply Direct with capacitor 33nF
Method coupling for signal I/O Capacitive clamp long 1 meter
Test duration ≥ 120 second
Test
Coupling port Test voltage Result criterion Remark
A.C. power supply
± 1kV A E.U.T. operated as
intended
Constructor Product Report reference Date of test report Page
A.S. Distribuzione S.r.l. 99.99M R-21 EMC 2012 23-01-2012 34 of 41
ELETECH S.r.l. Via Garcia Lorca 29 23871 Lomagna (LC) Italy Tel. 0039.039.99340.1 Fax. 0039.039.9991289 e-mail: [email protected] - http://eletechsrl.it
10.4. Immunity test: surge
Scope To assess the performances of the appliances when they are
submitted to over voltage from switching and lightning transients.
Reference standard EN 61000-4-5 EN 55014-2 + A1 + A2 Table 12
EUT operation mode # 1
EUT configuration mode # 1
Port A.C. power supply
Verdict
COMPLIANT
Test level (background grey)
Installation
class
AC power supply and a.c.
I/O directly connected to
the mains network.
Coupling mode
AC power supply and a.c.
I/O don’t directly
connected to the mains network.
Coupling mode
DC power supply and d.c. I/O
directly connected
thereto
Coupling mode
Unsymmetrical operated
circuit/lines
Coupling mode
Symmetrical operated
circuit/lines
Coupling mode
Unsymmetrical operated circuit/lines
Coupling mode
Line to
line
Line to
ground
Line to
line
Line to
ground
Line to
line
Line to
ground
Line to
line
Line to
ground
Line to
line
All line to
ground
Line to
line
Line to
ground
0 NA NA NA NA NA NA NA NA NA NA NA NA
1 NA 0,5 NA NA NA NA NA 0,5 NA 0,5 NA NA
2 0,5 1 NA NA NA 0,5 0,5 1 NA 1 NA 0,5
3 1 2 1 2 1 1 1 2 NA 2 NA 2
4 2 4 2 4 2 2 2 4 NA 4 NA 4
5 X X 2 4 2 2 2 4 NA 4 NA 4
Test equipment
Equipment Model Manufacturer Serial number
Surge generator VCS 500 EM TEST 0995-03
Set surge generator
Method coupling Source impedance 2 ohm
Line – line = capacitor 18uF
Line – earth = capacitor 9uF + impedance 10 ohm
Method coupling for shielded cable I/O Source impedance 2 ohm, cable long 20 meter, with
shielded connect to earth
Coupling phase 90° - 270°
Number of surge 5 for each parameter combination
Repetition rate Max 1/minute
Constructor Product Report reference Date of test report Page
A.S. Distribuzione S.r.l. 99.99M R-21 EMC 2012 23-01-2012 35 of 41
ELETECH S.r.l. Via Garcia Lorca 29 23871 Lomagna (LC) Italy Tel. 0039.039.99340.1 Fax. 0039.039.9991289 e-mail: [email protected] - http://eletechsrl.it
10.4. Immunity test: surge
Test
Coupling port Coupling mode and phase
Test voltage Result criterion
Remark
A.C. power
supply
Differential
(line – line) 90° - 270°
± 500V A E.U.T. operated as intended
± 1kV A E.U.T. operated as intended
A.C. power supply
Common (line – earth)
90° - 270°
± 1kV A E.U.T. operated as intended
± 2kV A E.U.T. operated as intended
Constructor Product Report reference Date of test report Page
A.S. Distribuzione S.r.l. 99.99M R-21 EMC 2012 23-01-2012 36 of 41
ELETECH S.r.l. Via Garcia Lorca 29 23871 Lomagna (LC) Italy Tel. 0039.039.99340.1 Fax. 0039.039.9991289 e-mail: [email protected] - http://eletechsrl.it
10.5. Immunity test: conducted disturbance, induced RF field
Scope To assess the performances of the appliances when they are
submitted to induced RF field.
Reference standard EN 61000-4-6 EN 55014-2 + A1 + A2 Table 7
EUT operation mode # 1
EUT configuration mode # 1
Port A.C. power supply
Verdict
COMPLIANT
Test level (background grey)
Level Voltage level (e. m. f.)
(unmodulated, rms)
1 1
2 3
3 10
x x
Test equipment
Equipment Model Manufacturer Serial number
RF signal generator SML 03 Rohde & Schwarz 100162
Amplifier 150A400 Amplifier Research 0330804
CDN M3 MEB 12859
Set RF generator
Frequency range 0.15 - 230 MHz
Modulation AM 80% 1 kHz sine-wave
Step 1%
Dwell time 3 second
Test
Coupling port Coupling method Result criterion Remark
A.C. power supply
CDN M3 A E.U.T. operated as
intended
Constructor Product Report reference Date of test report Page
A.S. Distribuzione S.r.l. 99.99M R-21 EMC 2012 23-01-2012 37 of 41
ELETECH S.r.l. Via Garcia Lorca 29 23871 Lomagna (LC) Italy Tel. 0039.039.99340.1 Fax. 0039.039.9991289 e-mail: [email protected] - http://eletechsrl.it
10.5. Immunity test: conducted disturbance, induced RF field
Scope To assess the performances of the appliances when they are
submitted to induced RF field.
Reference standard EN 61000-4-6 EN 55014-2 + A1 + A2 Table 7
EUT operation mode # 1
EUT configuration mode # 1
Port A.C. power supply
Verdict
COMPLIANT
Test level (background grey)
Level Voltage level (e. m. f.)
(unmodulated, rms)
1 1
2 3
3 10
x x
Test equipment
Equipment Model Manufacturer Serial number
RF signal generator SML 03 Rohde & Schwarz 100162
Amplifier 150A400 Amplifier Research 0330804
CDN M3 MEB 12859
Set RF generator
Frequency (MHz) 0.15 , 20, 40, 60, 80
Modulation AM 80% 1 kHz sine-wave
Step -
Dwell time 180 seconds for every frequency
Test
Coupling port Coupling method Frequency (MHz) Result criterion Remark
A.C. power supply
CDN M3 0.15 A E.U.T. operated as
intended
A.C. power supply
CDN M3 20 A E.U.T. operated as
intended
A.C. power supply
CDN M3 40 A E.U.T. operated as intended
A.C. power supply
CDN M3 60 A E.U.T. operated as
intended
A.C. power supply
CDN M3 80 A E.U.T. operated as
intended
Constructor Product Report reference Date of test report Page
A.S. Distribuzione S.r.l. 99.99M R-21 EMC 2012 23-01-2012 38 of 41
ELETECH S.r.l. Via Garcia Lorca 29 23871 Lomagna (LC) Italy Tel. 0039.039.99340.1 Fax. 0039.039.9991289 e-mail: [email protected] - http://eletechsrl.it
10.6. Immunity test: voltage dips and short interruptions
Scope To assess the performances of the appliances when they are
subjected to voltage dips, short interruptions and voltage variations.
Reference standard EN 61000-4-11 EN 55014-2 + A1 + A2 Table 13
EUT operation mode # 1
EUT configuration mode # 1
Port A.C. power supply
Verdict
COMPLIANT
Test level
Test Test level in % of Ut Duration
(in periods of rated frequency)
Interruption N° 1 0 0,5
Voltage dips N° 2 40 10
Voltage dips N° 3 70 25
Ut = power supply of E.U.T. (230V a.c.)
Test equipment
Equipment Model Manufacturer Serial number
Dips simulator PFS 500 EM TEST 0296-04
Test
Voltage test level % of Ut
Reduction time (ms)
Dip starting phase
Result criterion
Remark
-100% 10
0° A E.U.T. operated as intended
-60% 200
0° B Change speed motor, after the test E.U.T. operated as intended
-30% 500
0° B Change speed motor, after the
test E.U.T. operated as intended
Constructor Product Report reference Date of test report Page
A.S. Distribuzione S.r.l. 99.99M R-21 EMC 2012 23-01-2012 39 of 41
ELETECH S.r.l. Via Garcia Lorca 29 23871 Lomagna (LC) Italy Tel. 0039.039.99340.1 Fax. 0039.039.9991289 e-mail: [email protected] - http://eletechsrl.it
11. Photo
Photo 1 Emission measurement: disturbance power Photo 2 Emission measurement: continuous disturbance
Photo 3 Emission measurement: harmonics and flicker Photo 4 Immunity test: conducted disturbance, induced
RF field
Photo 5 Immunity test: voltage dips and short
interruptions Photo 6 Immunity test: electrical fast transients, burst
Constructor Product Report reference Date of test report Page
A.S. Distribuzione S.r.l. 99.99M R-21 EMC 2012 23-01-2012 40 of 41
ELETECH S.r.l. Via Garcia Lorca 29 23871 Lomagna (LC) Italy Tel. 0039.039.99340.1 Fax. 0039.039.9991289 e-mail: [email protected] - http://eletechsrl.it
11. Photo
Photo 7 Immunity test: surge Photo 8 Immunity test: electrostatics discharger ESD
Photo 9 Immunity test: electrostatics discharger ESD
Constructor Product Report reference Date of test report Page
A.S. Distribuzione S.r.l. 99.99M R-21 EMC 2012 23-01-2012 41 of 41
ELETECH S.r.l. Via Garcia Lorca 29 23871 Lomagna (LC) Italy Tel. 0039.039.99340.1 Fax. 0039.039.9991289 e-mail: [email protected] - http://eletechsrl.it
12. Modify
Modify introduced to EMC test compliance
Port Test fail Modify
A.C. power supply Emission conducted Change EMI Filter with model:
High & Low Corporation
EMI Filter - IEC Inlet Filters SS1 series Standard case
Voltage 250V Current rating 6A
Capacitor Cx 0,1µF Inductor L 2x0,8mH
Capacitor Cy 2x200pF