Transcript
Page 1: PV BREAKERS/ISOLATORS RESET … · THERMAL CIRCUIT BREAKER LOAD B A T RESET 285060F60 AMPERE THERMAL CIRCUIT BREAKER LOAD B A T 0 OFF name 0 OFF MCB ANL 350A With Power assist the

victron energyBLUE POWER

12.8V-200AhLithium

Smart LiFePO4

victron energyBLUE POWER

12.8V-200AhLithium

Smart LiFePO4

victron energyBLUE POWER

AGM Super Cycle BatteryAGM 12-125

RESET

60 A

MP

ER

ETH

ER

MA

L C

IRC

UIT

BR

EA

KE

R

2850

60F

L O A D

BAT

RESET

60 A

MP

ER

ETH

ER

MA

L C

IRC

UIT

BR

EA

KE

R

2850

60F

L O A D

BAT

0 OFF

name

0 OFF

MCB

ANL

350A

With Power assist the MultiPlus can add3KW to the output load when needed.Together with the adjustable 50A input thisall adds up to the max sum of input andoutput current of 50+25=75A. An Earthleakage device with breaker or acombination MCB/RCD must be installedon the output. Cable size must be adjustedaccordingly.

Recommended AC Out-1 cable/breaker size MultiPlusAC Out-2 only is available when power ispresent on AC IN. During battery operationit will be disconnected.AC Out-2 supports up to 25A.An Earth leakage device with breaker or acombination MCB/RCD must be installedon the output. Cable size must be adjustedaccordingly.

Recommended AC Out-2 cable/breaker size MultiPlus120 VOLT AC IS EXTREMELYHAZARDOUS !!!DO NOT TOUCH ANY LIVE WIREDPARTS OF THE INSTALLATION !!!WHEN IN DOUBT, ALWAYS CONSULTYOUR VICTRON DEALER !!!

WARNING

Drawing BJE-276A

RESET

60 A

MP

ER

ETH

ER

MA

L C

IRC

UIT

BR

EA

KE

R

2850

60F

L O A D

BAT

BUSBARPOSITIVE

SUPPLIED UTP CABLE

BMS 2A

Spare xxA

Battery Pre Main Fuses

BMV 100mA

Li-DISTRIBUTION

VE.Bus MAINS DETECTOR MultiPlusREMOTE PANEL

12.8V-200AhSmart LiFePO4

POS. NEG.

CYRIX Li CHARGE 230

CYRIX LiCHARGE

230

Maximum 5mA

BMS ON/OFF

ANL

350A

The VE.Bus BMS is enlargedvisible in this drawing.The BMS GND is not connectedto prevent ground loops.Ground comes through theVE.Bus UTP cable.

xxxAMEGA

xxxAMEGA

xxxAMEGA

xxxAMEGA

xxxAMEGA

MAIN DCDISTRIBUTION

BUSBARPOSITIVE

2 x Lithium

MAIN SWITCH-2

PV BREAKERS/ISOLATORS

VE

.Bus

COLOR CONTROL GX

VE

-direct-1

VE

-direct-2

SMART BATTERY PROTECT 220

SOLAR ARRAY

VE.Bus BMS

FROM MPPT

FROM MultiPlus

THE BMV SHUNT CAN BE UPGRADEDFROM STANDARD 500A TO 1000A.THE BMV SHUNT IS MOUNTEDDIRECT ON BOTH BUSBARS.KEEP NEGATIVE BATTERY CABLES

ALL AS SHORT AS POSSIBLE ANDALL AT THE SAME LENGTH !

KEEP POSITIVE BATTERY CABLESALL AS SHORT AS POSSIBLE ANDALL AT THE SAME LENGTH !

M8 CIRCULARCONNECTOR

M8 CIRCULARCONNECTORS

The SmartBatteryProtect must beprogrammed for Li-Ion mode-C and 12 Volteither through programming on the deviceitself or with a Bluetooth enabledsmartphone or tablet.Connect the load disconnect output of theVE.Bus BMS to Remote H terminal.

CENTRALNEGATIVE BUSBAR

INVERTER/CHARGERMultiPlus / 3KW/12V/120V-60Hz AC

BMV-712 SMART

SMART MPPT

SmartSolar charge controllerMPPT 100 | 50

12/24V 50A

Bul

k

Abs

orbt

ion

Floa

t

BATTERY PV

+ - - +

victron energyBLUE POWER

Battery100V 50APV

IP43! i

max

VE

-direct

FUSE

CCGX 1A

5x20mmCCGX POWER +

VRMWORLDE

THE

RN

ET

V+GND

BMV POWER +

ISOLATION TRANSFORMEROR GALVANIC ISOLATORSHOULD BE INSERTEDHERE IF NEEDED.INCLUDING NECESSARYBREAKERS.

SHORE POWERCONNECTION

Drawing BJE-276A

125/250VEasy Lock

50A

Shore Generatorpower power

MultiPlusAC out-2

MultiPlusAC out-1

from MultiPlusAC DISTRIBUTION

120V/60Hz ACGENERATOR 4KW

120V/60Hz AC

When operating in inverter mode, the Neutral output ofa inverter/charger must be connected to ground toguarantee proper functioning of a GFCI or RCD device.In case of a split phase supply the Neutral also mustbe grounded.The primary Case ground connection from a invertercharger like a Multi or a Quattro, must be connected tothe Central Negative Busbar of the DC system. Size ofthis cable must be identical to connected DC negative.

IMPORTANT INFORMATION ! IMPORTANT INFORMATION ! IMPORTANT INFORMATION ! IMPORTANT INFORMATION ! IMPORTANT INFORMATION !

VE.Bus BMS mainsdetector inside MultiPlus

M8 CIRCULARCONNECTOR

BTV CABLEBTV CABLE

M8 CIRCULARCONNECTOR

30

50

31

ALTERNATOR

12V Charger

B+D+B-

12V-150AALTERNATOR

INTERNALALTERNATOR

FUSE

STARTERMOTOR

BMV-B2 / 100mA FUSE

175AAMI

ORION-Tr SMART-1

In both Orion-Tr Smart Ignition remote on/offand engine detection override are active

WIRE LINKBETWEEN L & H

HL

FROM STARTER+(30)

MAIN SWITCH-3

IGNITION

30 15

Charge light

xx AMP.FUSE

FROM ALTERNATOR D+

OFF

ONm

10A FUSE

Blue SmartCharger 12V-5ASTARTER-MOTOR

Orion-Tr Smart

Non-isolated DC/DC charger12 I 12 - 30

on/off

victron energyBLUE POWER

Input Output

IP43iI 8-17V

PowerI 10-15VI 360W (30A)

IN OUT

+ - +

GND

Orion-Tr Smart

Non-isolated DC/DC charger12 I 12 - 30

on/off

victron energyBLUE POWER

Input Output

IP43iI 8-17V

PowerI 10-15VI 360W (30A)

IN OUT

+ - +

GND

ORION-Tr SMART-2

RESET

60 AMPERETHERMAL CIRCUIT BREAKER

285060F

LOAD

BAT

RESET

60 AMPERETHERMAL CIRCUIT BREAKER

285060F

LOAD

BAT

SELECTSETUP

BATTERY MONITORBMV-712 SMART

V

victron energyBLUE POWER

MAIN

color

victron energyBLUE POWER

control

victron energy

InvertingAC Input AC Loads

0W 45W

75%- +

219W12.8V 17.1A -75W

DC Power

victron energyPV-Charger

345W

MAIN SWITCH-1

HL

ORION-1 L/H-CONTACT

ENGINE SYSTEM

WIRE LINKBETWEEN L & H

ORION-2 L/H-CONTACT

Starter BatteryIP-65 | waterproof

S

victron energyB L U E P O W E R

mode

li-ion

recondition

high [14.7V]

normal [14.4V]

blue smartcharger

12V 5AStarter Battery +

MAIN FUSES Orion Inputsas close to starter battery

as possible

Conn-G Batt+

Conn-G Batt+

Conn-F Batt-

Conn-F Batt-

Conn-L Case ground

Shore power Generator power

BP220 GND-CCGX-

CYRIX LI-

MultiPlus Case Ground

MultiPlus Batt-

MultiPlus Batt-

Engine-

MPPT-

Load 1 - Load 2 -

Load 3 -

Load 4 -

Load 5 -

Load 1 +

Load 2 +

Load 3 +

Load 4 +

Load 5 +

MPPT +

ORION 1 +

ORION 2 +

BUSBARPOSITIVE

POSITIVEBUSBAR

OFF

ON

BTV

CA

BLE

BTV

CA

BLE

CCGX POWER +

VE.Bus MAINS DETECTOR MultiPlus

ALARM LED +

BMS POWER+BMS LOAD DISCONNECTBMS CHARGE DISCONNECT

ALARM LED -

+B1+B2

MultiPlus Batt +

MultiPlus Batt +

400AMEGA

OFF

ON

Shore Gen0

AC BREAKERSTOWARDSMultiPlus

MAIN INCOMING

Recommended DC cable/fuse size MultiPlus Recommended AC INcable/breaker size MultiPlusAC IN must be protected by a circuitbreaker rated at 50A max or less. Thisdepends heavily on the size of theconnected power source.The input currentmust be adjusted to fit the size of theconnected power source.The breaker and cable size for AC INshould be adjusted accordingly.

0 OFF

:hager

0 OFF

:hager

0 OFF

:hager

0 OFF

:hager

0 OFF

name

0 OFF

MCB

0 OFF

name

0 OFF

MCB

AC Out-1 & AC Out-2

0 OFF

name

0 OFF

MCB

0 OFF

name

0 OFF

MCB

ON

1 2

V-SENSET-SENSE AUX1 AUX2RELAY

GNDCHARGETRICKLE K1 K2

+ - + - + - + - + -NC NOS1 S2 + COM NC NO COM

AC IN-1

GROU

ND

BATTERY__

BATTERY++

BATTERY

BATTERY

LIN

E

NEUT

RAL

AC OUT-2

LIN

E

NEUT

RAL

AC OUT-1

GROU

ND

LIN

E

NEUT

RAL

GROU

ND

LIN

E

NEUT

RAL

VE.Bus-1 VE.Bus-2

L N G L N G L N

NO

T IN

US

E

MultiPlus12 |3000 |120

charger inverterinverter onoverloadlow batterytemperature

mains onbulkabsorptionfloat

I on

charger onlyO off

.battery charger

.powerassist.transfer switch.three phase

.sinewave inverter

.parallel connectable

AC transfer capacity: 50A | Inverter 120V

VOLT

VA AM

P

www.victronenergy.com

CE

victron energyBLUE POWER

Battery

AC in 1 AC out 1

AC out 2

vic

tro

n e

ne

rgy

BL

UE

PO

WE

R

VE.B

us B

MS

Mai

ns d

etec

tor

IN IN OUT-1 OUT-1 OUT-2

MultiPlus AC OUT-1

MultiPlus AC OUT-2

MultiPlus AC IN-1

VE.Bus to CCGX

VE.Bus mains detector to BMS

Starter Battery +

BMV-712 Smart120V Switched load-1120V Switched load-2120V No Break load-1120V No Break load-2

Blue Smart charger

0-5 m cable length: 4 x 50SQmm, 5-10 m cablelength: 4 x 70SQmm. When used in closedconduits, cable size should double. Cable lengthstands for the distance between the battery and theMultiPlus connections !!! Recommendations arewithout other loads in the system and these alsoshould be taken into account for proper mainbattery, main fuse & main switch cables !!!Fuse size should be 400A.

FUSES5x20mm

Top Related