PLUMBING DESIGNPLUMBING DESIGN
© Copyright 2008 HVAC Design Solutions 1
Essential Design Programs with Accurate Sizing Calculations help to “Streamline Your Design”
Essential Design Programs with Accurate Sizing Calculations help to “Streamline Your Design”
HHVAC VAC DDESIGN ESIGN SSOLUTIONSOLUTIONS ENGINEERING SOFTWAREENGINEERING SOFTWARE
“Plumbing Design” from HVAC Design Solutions is a package of software programs for most of the Plumbing Designer’s sizing tasks:
Fixture Unit/GPM Calcs Water System Sizing Waste & Vent System Sizing Roof Drain System Sizing Natural Gas System Sizing Water Heater Sizing Extensive Help Files, and “Extras”
© Copyright 2008 HVAC Design Solutions 2
OverviewOverview
Reduce your dependence on Reference Books, Charts, Graphs, and “Rules of Thumb”.
Eliminate many of the usual Plumbing Design Tasks
Reduce common errors and mistakes Create an easy-to-follow, step-by-
step “Procedure for Plumbing Design” for all projects.
© Copyright 2008 HVAC Design Solutions 3
““Streamline Your Design”Streamline Your Design”
Software Package contains most of the sizing calculations and procedures for typical projects
© Copyright 2008 HVAC Design Solutions 4
indexp2.XLS#'WASTE-SCHED'!B10
indexp2.XLS#'VENT-SCHED'!B10
indexp2.XLS#'ROOFDR-SCHED'!E3
indexp2.XLS#'STORMPIPE-SCHED'!D4
indexp2.XLS#'WATERHTR-CALCS'!C6
indexp2.XLS#'GAS-SCHED1'!F3
indexp2.XLS#'GAS-SCHED2'!F3
JUMP TO FILE
indexp2.XLS#INDEX!C10
BASIC PROJECT INPUT SHEET
WASTE AND VENT PIPE SIZING
ROOF DRAINS, VERTICAL AND HORIZONTAL PIPE SIZING
PROJECT INFORMATION
PLUMBING CALCS DESIGN
indexp2.XLS#'WATER-SCHED1'!B10
indexp2.XLS#'WATER-SCHED2'!A10
indexp2.XLS#'GASPIPE-DIAG.'!E1
indexp1.XLS#INDEX!C10
indexp1.XLS#'FU-CALCS'!B4
MEDICAL GAS PIPING CALCULATIONS - PRELIMINARY
indexp1.XLS#PIPESIZE!B10
indexp1.XLS#'W&V SIZES'!B3
indexp1.XLS#ROOFDR!G4
indexp1.XLS#MEDGAS!D10
FIXTURE UNIT CALCULATIONS
WATER PIPE SIZING CALCULATIONS
NATURAL GAS PIPE SIZING SCHEDULE - LOW PRESSURE
NATURAL GAS PIPE SIZING SCHEDULE - MEDIUM PRESSURE
PRELIMINARY WATER PIPE SIZING SCHEDULE
HORIZONTAL ROOF DRAINAGE PIPING SCHEDULE
GAS PIPE SIZING DIAGRAM
WATER PIPE SIZING SCHEDULE
WASTE PIPE SIZING SCHEDULE
VENT PIPE SIZING SCHEDULE
ROOF DRAIN, LEADER, OR VERTICAL PIPE SCHEDULE
WATER HEATER SIZING CALCULATIONS
CONTENTS
indexp1.XLS#'FU-GPM'!A5
PLUMBING SCHEDULE DESIGN
INDEXP.xls#INDEX!C10
INDEXP.xls#PROJ.INFO!D2
WATER FIXTURE UNIT TO GPM CONVERSIONS
AIR COMPRESSOR CALCULATIONS indexp1.XLS#AIRCOMP!B11
Quick Links to all calculation programs
Extensive Calculation ProgramsExtensive Calculation Programs
“Any One of these programs is worth the cost of the Entire Package!”
© Copyright 2008 HVAC Design Solutions 5
HELP
BASIC PROJECT INFORMATION
PROJECT NAME :
PROJECT NUMBER :
PROJECT LOCATION :
DATE :
TYPE OF BUILDING :
SUMMER OUTDOOR DESIGN DRY BULB TEMP. (DEG. F):
WINTER OUTDOOR DESIGN DRY BULB TEMP. (DEG. F):
INDOOR DESIGN TEMP. - SUMMER (DEG. F) :
INDOOR DESIGN TEMP. - WINTER (DEG. F) :
PROJECT ELEVATION (FEET) :
PROJECT MANAGER :
PROJECT ENGINEER :
CLIENT :
CLIENT CONTACT NAME:
75.0
-6.0
OAKPARK OFFICE BLDG. 3
134-08
CHICAGO, IL
05/06/08
JOHN GOREMANN
"YOUR COMPANY NAME"
OFFICE
91.0
ADS ARCHITECTS
70.0
670
BILL REECE
JIM EDMOND
Begin with Basic Project Information input
Typical Project StartupTypical Project Startup
Information automatically transfers to all programs
Design Conditions are used in some calculations
© Copyright 2008 HVAC Design Solutions 6
Input Quantity of Each FixtureInput Quantity of Each Fixture
FLUSH VALVES = 1, FLUSH TANKS = 2 1
FU EACH TOTAL FU FU EACH TOTAL FU
BATHTUB OR COMBINATION BATH/SHOWER 2 3.0 6.0 3.0 6.0
BATHTUB WITH 3/4" FILL VALVE 8.0 0.0 8.0 0.0
BIDET 1.0 0.0 1.0 0.0
CLOTHES WASHER, DOMESTIC 3.0 0.0 3.0 0.0
DENTAL UNIT, CUSPIDOR 1.0 0.0 1.0 0.0
DISHWASHER, DOMESTIC 1.5 0.0 1.5 0.0
DRINKING FOUNTAIN OR WATERCOOLER 3 0.5 1.5 0.0 0.0
FIXTURE UNIT CALCULATIONS
FIXTURE TYPE QUANTITY
PROJECT NAME:
DATE:
PROJECT NUMBER:
COLD WATER FIXTURE UNITS *
HOT WATER FIXTURE UNITS *
RESET/CLEAR
Count the Fixtures for the project and input the quantities of each type
Fixture Unit Values may be edited to meet local Codes
© Copyright 2008 HVAC Design Solutions 7
Program Calculates TotalsProgram Calculates TotalsSINKS - SERVICE OR MOP BASIN, 3" DRAIN 2 2.5 5.0 2.5 5.0
SINKS - SERVICE, FLUSHING RIM 20.0 0.0 0.0 0.0
SINKS - SPECIAL PURPOSE, 2" DRAIN 2.5 0.0 2.5 0.0
SINKS - SPECIAL PURPOSE, 3" DRAIN 2.5 0.0 2.5 0.0
SINKS - WASHUP, EACH SET OF FAUCETS 1.5 0.0 1.5 0.0
URINAL, 1.0 GPF FLUSH VALVE 4 13.3 53.0 0.0 0.0
URINAL, GREATER THAN 1.0 GPF FLUSH VALVE 0.0 0.0 0.0 0.0
URINAL, FLUSH TANK 2.0 0.0 0.0 0.0
WASHFOUNTAIN, 1-1/2" DRAIN 3.0 0.0 3.0 0.0
WASHFOUNTAIN, 2" DRAIN 3.0 0.0 3.0 0.0
WATER CLOSET - 1.6 GPF GRAVITY TANK 2.5 0.0 0.0 0.0
WATER CLOSET - 1.6 GPF FLUSHOMETER TANK 2.5 0.0 0.0 0.0
WATER CLOSET - 1.6 GPF FLUSH VALVE 6 20.8 125.0 0.0 0.0
WATER CLOSET - GREATER THAN 1.6 GPF TANK 5.5 0.0 0.0 0.0
WATER CLOSET - GREATER THAN 1.6 GPF VALVE 0.0 0.0 0.0 0.0
KITCHEN EQUIPMENT - WATER GPM
TOTALS 201.5 17.0
COLD WATER FU
HOT WATER FU
Input Fixture Quantities, and the Total FU and Total GPM are calculated, per Local Code requirements
© Copyright 2008 HVAC Design Solutions 8
Water System Sizing CalcsWater System Sizing Calcs
FLUSH VALVES = 1, FLUSH TANKS = 2 1
SIZE MAX. GPM VEL.
DEMAND FLOW RATE (GPM) 94 1/2 2 1.4
WATER MAIN PRESSURE (PSIG) 100 3/4 6 3.2
PRESSURE DROP THRU METER (PSIG) 7 1 11 3.9
PRESSURE REDUCING VALVE - PRESSURE (IF REQUIRED) 80 1 1/4 24 5.2
PRESSURE DROP THRU BACKFLOW PREVENTER (PSIG) 5 1 1/2 32 5.6
STATIC HEIGHT OF HIGHEST FIXTURE ABOVE MAIN (FT) 30 13 2 67 6.2
PRESSURE DROP THROUGH WATER TREATMENT (PSIG) 10 2 1/2 110 7
RESIDUAL PRESSURE REQUIRED AT LAST OUTLET (PSIG) 25 3 180 6.5
PRESSURE AVAILABLE FOR PIPING LOSS (PSIG) 27 4 300 8
PRESSURE BOOSTER PUMP (IF REQUIRED) (PSIG) 0 5 460 6.8
TOTAL DEVELOPED LENGTH OF LONGEST PIPE RUN (FT) 600 6 700 8
MAXIMUM ALLOWABLE PIPE PRESS. DROP (PSIG/100 FT) 4.5 8 1200 8.2
PROJECT NUMBER:
DATE:
AVAILABLE WATER PRESSURE CALCULATIONS PIPE SIZE SCHEDULE (@ MAX. ALLOWABLE PD/100 FT)
PROJECT NAME:
PRINTTotal Demand transferred from Fixture Unit Totals
Adding Project specific information…...
Results in Allowable Pipe Pressure Drop/100’ for “Longest Run” sizing
© Copyright 2008 HVAC Design Solutions 9
ERROR
FROM TO
1 2 4 0 4 3/4 4 1
2 3 42 0 25 1 1/2 2
3 4 250 100 2 1/2 3
4 5 475 135 2 1/2 2
0 0
0 0
PROJECT NUMBER:
PROJECT NAME:
FLUSH TANK FIXTURE UNITS
(FU)
FLUSH VALVE FIXTURE UNITS
(FU)
FLOW RATE (GPM)
90 DEG. STANDARD
ELBOW
DATE:
PIPE SECTION
MAXIMUM ALLOWABLE PRESSURE DROP - LONGEST RUN (PSIG/100 FT.)
45 DEG. STANDARD
ELBOW
NOTE: INPUT EITHER FLUSH TANK OR FLUSH VALVE, NOT BOTH.
PIPE SIZES FOR MAIN (LONGEST
RUN)
NUMBER OF EACH TYPE FITTING IN THE ASSOCIATED PIPE SECTION
90 DEG. STANDARD TEE (FLOW TURNS)
PRELIMINARY WATER PIPE SIZING SCHEDULE
4.5
RESET/CLEAR
Pipe Section SizingPipe Section SizingMax. Allowable PD/100’ Automatically transferred to Pipe Section Sizing Calcs
Input FU values for each pipe section
Input fittings and valves for each pipe section
© Copyright 2008 HVAC Design Solutions 10
ERROR
FROM TO
1 2 4 0 4 3/4 2.2 2.7
2 3 42 0 25 1 1/2 2.5 4.5
3 4 0 120 72 2 1/2 1.7 5.0
4 5 0 250 100 2 1/2 2.9 7.0
0 0 0.0 0.0
0 0 0.0 0.0
WATER PIPE SIZING SCHEDULE
4.5
PIPE SECTION
MAXIMUM ALLOWABLE PRESSURE DROP - LONGEST RUN (PSIG/100 FT.)
MAIN SIZE VELOCITY (FT./SEC.)
NOTE: INPUT EITHER FLUSH TANK OR FLUSH VALVE, NOT BOTH.
PROJECT NAME:
FLUSH TANK FIXTURE UNITS
(FU)
FLUSH VALVE FIXTURE UNITS
(FU)
FLOW RATE (GPM) MAIN SIZE
(INCHES)MAIN SIZE PD (PSI/100 FT.)
DATE:
PIPE SIZES FOR MAIN (LONGEST RUN)
PROJECT NUMBER:
RESET/CLEAR
Final, Accurate Pipe Section sizing, after corrections for actual fittings and valves
Final Water Pipe System SizingFinal Water Pipe System Sizing
Accurate Pipe sizing, NOT based on Rule-of-Thumb, like “add 50% for Fittings”!!
© Copyright 2008 HVAC Design Solutions 11
Waste & Vent Sizing - Individual PipesWaste & Vent Sizing - Individual Pipes
WASTE FIXTURE UNITS (FU): 30
WASTE SLOPE (1/4=1, OR 1/8=2): 1 2 1/2
WASTE VERTICAL LENGTH (FT.): 65 3
VENT FIXTURE UNITS (FU): 30
VENT TOTAL LENGTH (FT.): 46 2 1/2
VENT HORIZONTAL LENGTH (FT.): 12
SIZES
1 1/4 1 1/2 2 2 1/2 3 4
MAXIMUM UNITS
DRAINAGE PIPING (#1)
VERTICAL 1 2 (#2) 16 (#3) 32 (#3) 48 (#4) 256
HORIZONTAL @ 1/4"/FT. SLOPE 1 1 8 (#3) 14 (#3) 35 (#4) 216 (#5)
HORIZONTAL @ 1/8"/FT. SLOPE N/A N/A N/A N/A N/A 172 (#5)
MAXIMUM UNIT LOADING AND MAXIMUM LENGTH OF DRAINAGE AND VENT PIPING
WASTE & VENT SIZING AND MAX. LENGTHS
WASTE SIZE - VERT.:
VENT SIZE:
WASTE SIZE - HORIZ.:
Quick input of pipe section loading and lengths (W and/or V)
Resulting sizes for the section
Cross reference in chart form
© Copyright 2008 HVAC Design Solutions 12
Waste Pipe Sizing - Complete SystemWaste Pipe Sizing - Complete System
HELP
FROM TO
1 2 6 4 2 2 4 0
2 3 12 4 2 2 1/2 4 0
3 4 22 4 3 3 4 1
4 5 34 4 4 4 4 4
WASTE PIPE SIZING SCHEDULE
WASTE PIPE SECTIONWASTE FIXTURE
UNITS (FU)
WASTE PIPE VERTICAL LENGTH
(FT.)
WASTE PIPE SIZE -
VERTICAL
WASTE PIPE SIZE AT 1/4"/FT. SLOPE
WASTE PIPE SIZE AT 1/8"/FT. SLOPE
NUMBER OF WATER
CLOSETS ON PIPE SECTION
PROJECT NAME:
PROJECT NUMBER:
DATE:
OAKPARK OFFICE BLDG. 3
134-08
05/06/08
RESET/CLEAR
Input W-FU and vertical length for each pipe section
Required sizes at different slopes are calculated automatically
© Copyright 2008 HVAC Design Solutions 13
Vent Pipe Sizing - Complete SystemVent Pipe Sizing - Complete System
HELP
CAUTION
FROM TO
1 2 20 110 35 2 0 0
2 3 30 190 55 0 3 0
3 4 45 100 70 0 0 3
4 5 65 30 8 4 0 0
5 6 150 60 20 5 0 0
PROJECT NAME:
PROJECT NUMBER:
DATE:
OAKPARK OFFICE BLDG. 3
134-08
VENT PIPE SECTIONVENT FIXTURE
UNITS (FU)
VENT PIPE TOTAL
LENGTH (FT.)
VENT PIPE HORIZONTAL
LENGTH (FT.)
VENT PIPE SIZE (IF TOTAL AND
HORIZ. LEN. LESS THAN
ALLOWABLE LENGTH)
VENT PIPE SIZE (IF TOTAL LEN.
MORE THAN ALLOWABLE
LENGTH)
VENT PIPE SIZE (IF HORIZ. LEN. MORE THAN 1/3 OF ALLOWABLE TOTAL LENGTH)
VENT PIPE SIZING SCHEDULEEITHER TOTAL LENGTH OR HORIZONTAL LENGTH EXCEEDS CODE MAXIMUM ALLOWABLE. SIZE HAS BEEN INCREASED BY ONE PIPE SIZE.
05/06/08
RESET/CLEAR
Input V-FU, total length, and horizontal length for each pipe section
Required sizes are calculated automatically
© Copyright 2008 HVAC Design Solutions 14
Roof Drain and Vertical Pipe SizingRoof Drain and Vertical Pipe Sizing
HELP
3.00
1 1500 1000 2000 3 67 2147
2 2500 1200 2920 4 144 4613
3 3000 2500 3875 4 144 4613
4 1000 1000 3 67 2147
FLOW RATE (GPM)
DRAIN NUMBER
ROOF AREA (SQ. FT.)
(1) ADJACENT WALL - AREA
(SQ. FT.)
PROJECT NUMBER: 134-08
DATE: 05/06/08
(2) ADJACENT WALLS - AREA
(SQ. FT.)
TOTAL AREA - ROOF + WALLS
(SQ. FT.)
MAXIMUM AREA DRAIN OR PIPE
SIZE CAN CARRY (SQ. FT.)
SIZE OF ROOF DRAIN, LEADER,
OR VERTICAL PIPE (IN.)
PROJECT NAME: OAKPARK OFFICE BLDG. 3RAINFALL RATE FOR 100 YEAR, 60 MINUTE DURATION STORM IN
LOCAL AREA (INCHES/HR.):
ROOF DRAIN, LEADER, OR VERTICAL PIPE SCHEDULE
RESET/CLEAR
Input Roof Area served by Roof Drain
Input Local Rainfall Rate
Roof Drain size or Vertical Pipe sizes are calculated
Input Adjacent Wall Area where applicable
© Copyright 2008 HVAC Design Solutions 15
Roof Drain Piping System SizingRoof Drain Piping System Sizing
FROM TO
1 2 3500 1200 4100 5 139
2 3 2000 3000 3050 5 139
3 4 5500 4500 7075 6 222
4 5 3000 3000 5 139
RAINFALL RATE FOR 100 YEAR, 60 MINUTE DURATION STORM IN
LOCAL AREA (INCHES/HR.):3.00
(1) ADJACENT WALL - AREA
(SQ. FT.)
HORIZ. PIPE SIZE AT 1/8"/FT.
SLOPE (INCHES)
TOTAL AREA - ROOF + WALLS
(SQ. FT.)
PIPE SECTIONROOF AREA
(SQ. FT.)
FLOW RATE AT 1/8"/FT.
SLOPE (GPM)
PROJECT NAME:
PROJECT NUMBER:
(2) ADJACENT WALLS - AREA
(SQ. FT.)
DATE:
HORIZONTAL ROOF DRAINAGE PIPING SCHEDULE
RESET/CLEAR
Input Local Rainfall Rate
Input Roof Area served by Pipe Section
Input Adjacent Wall Area where applicable
Horizontal Roof Drainage Pipe Section sizes are calculated for 1/8”, 1/4”, and 1/2” pipe slopes
© Copyright 2008 HVAC Design Solutions 16
Water Heater Sizing (1)Water Heater Sizing (1)
TYPE OF BUILDING OR FACILITY:
FACILITY INCLUDE FULL KITCHEN? 1 = YES, 2 = NO 1
GPH EACH TOTAL GPH
BATHTUB FILL (EXCLUDING WHIRLPOOL TUBS) 20 0
BATHTUB AND SHOWER 5 75 375
BIDET 1 5 5
DISHWASHER - DOMESTIC UNDERCOUNTER 15 0
FOOT BASIN 3 0
LAUNDRY - DOMESTIC, STATIONARY TUB 28 0
LAVATORY - PRIVATE 2 0
LAVATORY - PUBLIC 6 0
SHOWER - SINGLE HEAD 3 75 225
20 x 20 IN. RACKS
18 x 18 IN. RACKS
UNDERCOUNTER TYPE
SINGLE TANK
DISHWASHER - CONVEYOR TYPE - WITHOUT INTERNAL STORAGE:
MULTIPLE TANK (DISHES FLAT)
PLUMBING FIXTURE TYPE QUANTITY
KITCHEN FIXTURE TYPE (ASSUMING SEPARATE BOOSTER
HEATER FOR 140 DEG. F TO 180 DEG. F HOT WATER WHERE REQUIRED)
PROJECT NAME:
PROJECT NUMBER:
DISHWASHER - DOOR TYPE - WITHOUT INTERNAL STORAGE:
DATE:
PROJECT ELEVATION:
KITCHENS:GENERAL PLUMBING FIXTURES:
DISHWASHER - FROM MANUFACTURER, IF AVAIL.
HOT WATER - GALLONS PER HOUR AT 140 DEG. F
16 x 16 IN. RACKS
WATER HEATER SIZING CALCULATIONS
RESET/CLEAR
HOSPITAL Select Type of Facility from drop-down list
Input quantity of each Fixture Type
© Copyright 2008 HVAC Design Solutions 17
Water Heater Sizing (2)Water Heater Sizing (2)
LAVATORY - PUBLIC 1 8 8
SHOWER - GENERAL 50 0
SHOWER - THERAPEUTIC 400 0
SINK - BARIUM 1 15 15
SINK - CLEANUP ROOM 1 15 15
SINK - CENTRAL SUPPLY 1 15 15
SINK - CLINICAL 1 10 10
SINK - CLINICAL, BEDPAN HOSE 15 0
SINK - LABORATORY 2 5 10
SINK - PHARMACY 1 5 5
SINK - PLASTER 1 15 15
SINK - SCRUB-UP 2 10 20
1424
1919
0.25
480
0.60
288STORAGE TANK CAPACITY (GALLONS):
POSSIBLE TOTAL MAXIMUM DEMAND (GPH):
DEMAND FACTOR:
PROBABLE MAXIMUM DEMAND (GPH):
STORAGE CAPACITY FACTOR:
POSSIBLE MAXIMUM DEMAND - FIXTURES (GPH):
75 0
139 0
1 8 8
60 0
240 0
1 45 45
180 0
40 0
1 30 30
1 90 90
1 45 45
495
1.00
359669
0.70
411
SINGLE POT SINK
TRIPLE POT SINK
VEGETABLE SINK
PREFLUSH (CLOSED TYPE)
PREFLUSH (HAND-OPERATED)
PRESCRAPPER (OPEN TYPE)
RECIRCULATING PREFLUSH
UTINSIL WASHERS
DISHWASHER MAKEUP WATER REQ.
HAND SINK
DOUBLE POT SINK
KITCHEN FIXTURES:
POSSIBLE MAXIMUM DEMAND - KITCHEN (GPH):
ALTITUDE CORRECTION FACTOR (IF ANY):
REQUIRED WATER HEATER OUTPUT (AT 140 DEG. F) (BTUH):
USABLE STORAGE CAPACITY FACTOR:
REQUIRED STORAGE TANK CAPACITY (GALLONS):
Input Kitchen Fixtures, as applicable
Demand Factor and Storage Factor are applied to Max. Demand, based on Type of Facility
Resulting in required Water Heater Output and required Storage Tank Capacity
© Copyright 2008 HVAC Design Solutions 18
Natural Gas Pipe Sizing (1)Natural Gas Pipe Sizing (1)
Start with a sketch of the Gas Piping system
© Copyright 2008 HVAC Design Solutions 19
Natural Gas Pipe Sizing (2)Natural Gas Pipe Sizing (2)
28.00 1.00 (PSI)
2.00 0.07 (PSI)
0.60 1.000 (SG MULT)
FROM TO
1 2 150 570 1 0 2
2 3 450 570 1 1/2 0
3 4 750 570 2 0 2
4 5 2500 570 3 0
5 6 2565 570 3 0 2
2 7 300 0 500 1 1/4 1
3 8 300 0 460 1 1/4
4 9 1750 0 420 3
5 10 65 0 320 3/4
PIPE SIZES FOR BRANCH
NUMBER OF EACH FITTING IN THE ASSOCIATED PIPE SECTION MEASURED LENGTH BRANCH - FROM METER (WITHOUT FITTINGS) (FEET)
GAS FLOW RATE (CFH)
MEASURED LENGTH MAIN - LONGEST RUN (WITHOUT FITTINGS)
(FEET)
PIPE SIZES FOR MAIN (LONGEST
RUN)
PIPE SECTION
NATURAL GAS PIPE SIZING SCHEDULE (LOW PRESSURE - BELOW 1.5 PSI)
90 DEG. STANDARD
ELBOW
INITIAL GAS PRESSURE (IN. WC) (28" WC PER PSI)
ALLOWABLE PRESSURE DROP (IN. WC)
GAS SPECIFIC GRAVITY PRINT
RESET/CLEAR
1. Input Local Gas conditions
2. Input Flow Rate and Lengths for “Longest Run” and Branches
3. Input Fittings and Valves for each section
4. Sizes are calculated for each Section
© Copyright 2008 HVAC Design Solutions 20
Medical Gas Pipe Sizing (Prelim.)Medical Gas Pipe Sizing (Prelim.)QUANTITY DIVERSITY FACTOR
PSI PER 100 FT. IN. HG PER 100 FT. PERCENT (%)
OXYGEN (O2)
NUMBER OF STANDARD OUTLETS 24 1.00 --- 33
NUMBER OF RESPIRATORY VENTILATORS 8 1.00 --- 100
NITROUS OXIDE (N2O)
NUMBER OF STANDARD OUTLETS 18 1.00 --- 50
NITROGEN (N2)
NUMBER OF STANDARD OUTLETS 18 2.00 --- 75
MEDICAL AIR (MA)
NUMBER OF STANDARD OUTLETS 24 1.00 --- 60
MEDICAL VACUUM (VAC)
NUMBER OF STANDARD OUTLETS 18 --- 1.00 60
NUMBER OF MAJOR SURGERY ROOMS 4 --- 1.00 100
NUMBER OF INTENSIVE CARE BEDS 6 --- 1.00 50
MEDICAL GAS SERVICE TYPEDESIGN FRICTION LOSS 1
Initial Pipe Sizing for Med. Gas Systems
© Copyright 2008 HVAC Design Solutions 21
Air Compressor SizingAir Compressor SizingFREE AIR USAGE AT 90 PSIG
(CFM)1
AIR HOIST - 1,000 LB. OR LESS 7 0.8
AIR HOIST - 2,000 LB. TO 10,000 LB 2 35 0.8
AIR HOIST - 10,000 LB. AND LARGER 1 105 0.8
ANGLE NUT SETTER - TO 5/16" (WEIGH 8 LBS.) 6 20 0.8
ANGLE NUT SETTER - 1/2" TO 3/4" (WEIGH 18 LBS.) 2 30 0.8
BLOWGUNS 1 25 0.8
BUSHING TOOLS (MONUMENTAL) 25 0.8
CARVING TOOLS (MONUMENTAL) 15 0.8
CHIPPING HAMMERS (WEIGH 2 - 4 LBS.) 3 12 0.8
CHIPPING HAMMERS (WEIGH 10 - 13 LBS.) 30 0.8
CHIPPING HAMMERS (HEAVY WEIGHT) 39 0.8
CONCRETE VIBRATORS 30 0.8
FILE AND BURR MACHINES 1 18 0.8
GREASE GUN 3 4 0.8
GRINDERS - HORIZONTAL (1-1/2" WHEELS AND UNDER) 10 0.8
GRINDERS - HORIZONTAL (2" AND 2-1/2" WHEELS) 2 20 0.8
TOOL OR EQUIPMENT QUANTITY USE FACTOR2
Calculates Total Anticipated Usage & Recommended Receiver Volume
© Copyright 2008 HVAC Design Solutions 22
Extensive “Quality Control” Plumbing Checklists are available in a separate “Plumbing Peer Review” Software Package
Coordination Between Disciplines
Contents: (Click on hyperlink to jump to the sheet checklist)
A Preliminary Review of Plans and SpecificationsB Demolition PlansC Architect and/or Owner CoordinationD Structural CoordinationE Mechanical CoordinationF Plumbing CoordinationG Civil Engineering CoordinationH Electrical Coordination
A Preliminary Review of Plans and Specifications1 Quickly review all Drawings in the Construction Document set, including Architectural,
Structural, Civil, Landscaping, Mechanical, Plumbing, Fire Protection, Electrical, FoodService, and any other discipline. Spend not more than one minute per sheet, average.
2 Make a list of any apparent discrepancies or questions while reviewing the set, and add‘flags’ to sheets where there are significant questions.
3 Quickly review the Specif ications by reading through the Table of Contents forMechanical and Plumbing work. Check the Table of Contents against the actualSpecification sections to verify all sections have been included. Make a list of questionsthat may come up during the cursory review.
4 Review Architectural T itle Sheet, or first sheet in the set, and make a list of the ProjectSquare Footage, Building Occupancy Type, Building Construction Type, GoverningCodes, Index of Drawings, and any other information that relates to Mechanical orPlumbing work.
5 Check for consistent appearance of Title Blocks, Drawing Scales, North Arrows,Professional Stamps, Company Logos, Sheet Numbers, Sheet Tit les, Issue Dates, andIssue Revisions on all sheets.
B Demolition Plans1 Verify that Demolition Symbols (cross-hatching, etc.) are clear and complete, and are
coordinated with other disciplines.2 Verify there are notes regarding potential hazardous materials (asbestos, lead paint,
etc.), and coordinate with Architect or other Prime Consultant and Owner.
““Plumbing Peer Review” SoftwarePlumbing Peer Review” Software
Over (70) Pages of Checklists and Spreadsheets for a thorough review of Plumbing Construction Documents
Plumbing Plan Review Items
Contents: (Click on hyperlink to jump to the sheet checklist)
A Preliminary Review of Plans and SpecificationsB Legend and Symbols, and Fixture Calculations SheetC Schedule SheetsD Plumbing Site PlanE Plumbing Demolition PlansF Plumbing Underground Floor PlanG Plumbing Floor PlansH Plumbing Roof PlansI Plumbing Medical/Lab/Process Piping PlansJ Central Plant Plumbing PlansK Plumbing Riser Diagram SheetsL Plumbing Detail Drawings
© Copyright 2008 HVAC Design Solutions 23
““Plumbing Peer Review” SoftwarePlumbing Peer Review” SoftwareC Plumbing Underground Floor Plan Return to Table of Contents
1 Read all Sheet Notes and verify they are clear and appropriate.2 Verify all References are correct. Follow references to indicated sheets.3 Coordinate Plumbing Underground Plan with Structural Grade Plan. Verify that
below-slab Footings and Grade Beams have been shown on the PlumbingUnderground Floor Plan, for underground pipe coordination. (If Footings and GradeBeams are not on Plumbing Underground Plan, they should be added to the‘background’).
4 Verify that any pipes passing over, under, or through Footings or Grade Beams havebeen coordinated with Structural Plans. Check on provisions for sleeving beams, etc.Verify depth of Footings and Grade Beams below floor slab, to check for anypotential conflicts.
5 Verify that Footings and Grade Beams are not directly below Plumbing Fixtureoutlets, Floor Drains, Floor Sinks, Plumbing Chases, or pipe drops, such as StormDrains and Overflow Drains. Verify coordination with pipes at Columns, such asSanitary Vents and Trap Primer water pipes, to avoid conflicts with Footings atColumns.
6 Check for locations of building expansion joints or seismic joints, and verify that pipeshave been designed to accommodate expansion joints.
7 Follow all Waste Pipe risers up to floors above. Place a pencil check-mark on eachriser as it is verified to continue on the floor above (or roof). Check for coordinatedlocations from floor to floor on each pipe riser.
8 After following each Waste pipe riser to the top, follow horizontally to the most remotefixture or drain connection point. Pencil in Fixture Units (FU) for all Fixtures andDrains served by each Waste riser. Sum the flow rates (FU) from the remote fixturesor drains, back to the risers. Pencil in the accumulated FU on the plans adjacent tothe pipes. Verify that Fixture Units are listed for all fixtures or drains and thatSchedules for each fixture are complete.
9 If the Floor Plan has references to larger scale plans (such as Enlarged Toilet RoomPartial Plans), follow to the referenced Enlarged Plan. Verify all pipe sizes arecoordinated from Floor Plan to Enlarged Partial Plan. Verify the Floor Plan andEnlarged Plan have the same background and are current with the latestArchitectural plans. Pencil in the Fixture Unit value for each Fixture or Drain on theEnlarged Plan, and sum the FU to the extent of the Enlarged Scale Plan. Transferthe total flow rates back to the original Floor Plan, for continuation.
Example of Quality Control Check List Items
© Copyright 2008 HVAC Design Solutions 24
FLUSH VALVES = 1, FLUSH TANKS = 2 1
SIZE MAX. GPM VEL.
DEMAND FLOW RATE (GPM) 96 1/2 2 1.4
WATER MAIN PRESSURE (PSIG) 100 3/4 6 3.2
PRESSURE DROP THRU METER (PSIG) 7 1 11 3.9
PRESSURE REDUCING VALVE - PRESSURE (IF REQUIRED) 80 1 1/4 24 5.2
PRESSURE DROP THRU BACKFLOW PREVENTER (PSIG) 5 1 1/2 32 5.6
STATIC HEIGHT OF HIGHEST FIXTURE ABOVE MAIN (FT) 30 13 2 67 6.2
PRESSURE DROP THROUGH WATER TREATMENT (PSIG) 10 2 1/2 110 7.0
RESIDUAL PRESSURE REQUIRED AT LAST OUTLET (PSIG) 25 3 180 6.5
PRESSURE AVAILABLE FOR PIPING LOSS (PSIG) 27 4 300 8.0
PRESSURE BOOSTER PUMP (IF REQUIRED) (PSIG) 0 0 5 460 6.8
TOTAL DEVELOPED LENGTH OF LONGEST PIPE RUN (FT) 600 6 700 8.0
MAXIMUM ALLOWABLE PIPE PRESS. DROP (PSIG/100 FT) 4.5 8 1200 8.2
AVAILABLE WATER PRESSURE CALCULATIONS PIPE SIZE SCHEDULE (@ MAX. ALLOWABLE PD/100 FT)
PROJECT NUMBER:
DATE:
WATER PIPE SIZING CALCULATIONSPROJECT NAME:
Calculation DocumentsCalculation Documents
After completing input and calculations, Output and Sizing Documents can be printed for submittal to building department officials and for addition to drawings and schedules
© Copyright 2008 HVAC Design Solutions 25
Extensive Plumbing Programs
MEDICAL GAS PIPING CALCULATIONS - PRELIMINARY
WATER FIXTURE UNIT TO GPM CONVERSION
ROOF DRAINS, VERTICAL AND HORIZONTAL PIPE SIZINGROOFDR
MEDGAS
FU-GPM
AIRCOMPAIR COMPRESSOR CALCULATIONS
PIPESIZE
W&V SIZES
FU-CALCSFIXTURE UNIT CALCULATIONS
WATER PIPE SIZING CALCULATIONS
WASTE AND VENT PIPE SIZING
Software ContentsSoftware Contents
HORIZONTAL ROOF DRAINAGE PIPING SCHEDULE
WATER HEATER SIZING CALCULATIONS
ROOF DRAIN, LEADER, OR VERTICAL PIPE SCHEDULE
GAS-SCHED1NATURAL GAS PIPE SIZING SCHEDULE - LOW PRESSURE (BELOW 1.5 PSI)
GAS-SCHED2NATURAL GAS PIPE SIZING SCHEDULE - MEDIUM PRESSURE (ABOVE 1.5 PSI)
ROOFDR-SCHED
STORMPIPE-SCHED
WATERHTR-CALCS
WASTE-SCHED
VENT-SCHED
WASTE PIPE SIZING SCHEDULE
VENT PIPE SIZING SCHEDULE
WATER-SCHED2WATER PIPE SIZING SCHEDULE
GASPIPE-DIAG.GAS PIPE SIZING DIAGRAM
Straightforward takeoff and input allows easy calculation and sizing of Plumbing Systems.
Extensive procedures, formulas, charts, and tables as prescribed by Plumbing Codes and as recommended by ASPE and ASHRAE have been included and have been used to establish the “Accurate” Plumbing System Sizes.
Multiple Programs are included, covering most of the typical Plumbing Design Tasks for most projects.
© Copyright 2008 HVAC Design Solutions 26
Features and BenefitsFeatures and Benefits
Significantly reduces “Reference Material Dependence” which can save a great deal of time and effort.
Output in the form of Compliance Documents or System Sizing Summaries for submittal to appropriate code enforcement officials or building departments.
Extensive “Help Files” that are hyperlinked to each program, form, or table.
© Copyright 2008 HVAC Design Solutions 27
Features and BenefitsFeatures and Benefits
Limited time “Special Pricing” available at our website www.hvacdesignsolutions.com
Plumbing Design Package Original Price: $250 US, Special Price: $189 US
Plumbing Peer Review Package Original Price: $200 US, Special Price: $148 US
© Copyright 2008 HVAC Design Solutions 28
PricingPricing
Current Version: 2.16, with latest update (03/31/2008) Free updates, as available.
To purchase Plumbing Design or Plumbing Peer Review, visit our website at www.hvacdesignsolutions.com and go to the Prices/Orders page
Software can be downloaded for immediate installation (with password) after purchase is confirmed
© Copyright 2008 HVAC Design Solutions 29
AvailabilityAvailability
OS: Windows® 98, 2000, XP, 2003, Vista Processor: Pentium® or equivalent Ram: 512MB (minimum recommended) Disk Space: 100 MB (recommended) Software: MS Word®, MS Excel®
© Copyright 2008 HVAC Design Solutions 30
System RequirementsSystem Requirements
Thank you for taking your time to review our Plumbing Design software packages
If you have any questions or comments, you can e-mail to: steve”at”hvacdesignsolutions.com , or support”at”hvacdesignsolutions.com
We also have an interactive demo of our Plumbing Design software that can be delivered, on request, via e-mail.
© Copyright 2008 HVAC Design Solutions 31