MACmetalarchitectural.com August,2018 V2
Molding &FlashingRoofing
3099, St. Bernard-Pilon, St-Mathieu-de-Beloeil,
QC J3G 4S5T. 450-464-5486 | F. [email protected]
Variable = Degree or inch / mm Units = inch and/or mm
MACmetalarchitectural.com
No. M59ABRoof flashing w/variable angle -1.75’’
No. M59AB Roof flashing w/variable angle -3’’
No. M58AB Roof flashing w/90 degree angle - 1.75’’
No. M58ABRoof flashing w/90 degree angle - 3’’
Roof flashing (straight or angled)
Roof flashing is the starting molding that must be ins-talled over the entire peri-meter of the roof. It is avai-lable straight or variable angle.
* Note that you must provide the required angle for the so-called variable option.
Roof flashingstraight or with angle(roofing installation)
No. M80ABValley
Noue(installation toiture)
The valley is a molding used when meeting an inner roof junction.
Valley(roofing installation)
Molding & FlashingProfile MS 1, MS 2 & MS Authentic
44.4
5mm
13 4"
VARIABLE
107.9
5mm
41 4
"
25.41
mm
1.0''
12.70
mm
1 2"
76.2
0mm
3"
VARIABLE
76.20
mm
3"
25.41
mm
1''
12.70
mm
1 2"
44.4
5mm
13 4"
107.95mm41
4"
25.41mm1.0''
12.70
mm
1 2"
76.2
0mm
3"
76.20mm3"
12.70
mm
1 2"
25.41mm1.0''
279.4mm11"
22.2mm78 "
279.4mm
11"
22.2mm7
8"
VARIABLE
2
MACmetalarchitectural.com
Variable = Degree or inch / mm Units = inch and/or mm
Jonction mur / toit(installation toiture)
The wall / roof junction mol-ding is used when you have a roof that comes in or dies in a wall. It is available in two versions, either 90 ° or va-riable.
* Note that you must provide the required angle for the so-called variable option.
Jonction roof / wall(roofing installation)
Molding & FlashingProfile MS 1, MS 2 & MS Authentic
No. M32ASingle slop ridge tile
Faitière(installation toiture)
La faîtière est appliquée sur l’arête de deux toits sortants.
La faîtière ventilée est sur-tout utilisée dans l’applica-tion de toit cathédrale.
Faîtière(installation toiture)
28.6mm
1 18 "63.5mm
21 2"
VARIABLE
158.8mm
61 4"
50.8mm2"
VARIABLE
63.5mm21
2"
50.8mm2"
61158.8mm
4"
28.6
mm
11 8"
28.6
mm
11 8"
41.3
mm
15 8"
25.4mm1"
76.2mm3"
50.8mm2"
101.6mm4"
57.2
mm
21 4"19.1
mm
3 4"A
127m
m5"
28.5
8mm
11 8"63.50mm21
2"
2.38
mm
3 32"
50.80mm2"
28.58mm
1 18 "
127m
m5"
VARIABLE
63.50mm
21 2"
50.80mm2"
No. M40AWall / roof w/90 degree angle junction
No. M41AWall / roof w/variable angle junction
No. M30AVented ridge cap
No. M31Anon-vented ridge cap
No. M70ABFixing bracket
Barquette de fixation(installation toiture)
The brackets are used to secure the valleys in place.
Fixing bracket(roofing installation)
3
MACmetalarchitectural.com
Variable = Degree or inch / mm Units = inch and/or mm
Molding & Flashing
No. M61A Roof junction flashing (slope change) convex
Solin de jonction (installation toiture & murale)
The junction flashing is used when there is a change of slope in the roof.
Solin de transition(installation toiture & murale)
The transition flashing shall be used when a project is incorporated with large cornices that are 2 in height and covered with a siding.
No. M60ARoof junction flashing (slope change) concave
Roof jonction flashing(roof & wall installation)
Jonction flashing(roof & wall installation)
Profile MS 1, MS 2 & MS Authentic
50.8
0mm
2"
28.58mm11
8"
50.8
0mm
2"
25.4
0mm
1"
VARIABLE
123.83mm
47 8"
25.41mm
1''
25.4
0mm
1"
76.2
0mm
3"
10
1.60m
m
4.0''
50.80
mm
2"
28.58mm1 18 "
76.20
mm
3"
VARIABLE
B
4
MACmetalarchitectural.com
Variable = Degree or inch / mm Units = inch and/or mm
No. M21AOutside Corner w/integrated J Trim
Coin extérieur(installation murale)
The outer corner is used to cover the junction of two outgoing walls.
No. M22AInside Corner
Coin intérieur(installation murale)
The inner corner is used for at the junction of two inco-ming walls.
Inside Corner(wall installation)
Outside Corner(wall installation)
Molding & FlashingProfile MS 1, MS 2 & MS Authentic
28.6
mm
11 8"
28.6mm11
8" 38.1mm11
2"
38.1
mm
11 2"
76.2mm3"
76.2
mm
3"
22.2mm7
8"
22.2
mm
7 8"
61.91mm27
16"
28.5
8mm
11 8"
28.58mm11
8"
61.9
1mm
27 16"
22.23mm7
8"
22.23mm7
8"
38.1
0mm
11 2"
38.10mm11
2"
5
Variable = Degree or inch / mm Units = inch and/or mm
MACmetalarchitectural.com
J Trim (installation murale)
The J or J trim is used on the sides and bottom of any ope-ning. Available in several forms depending on the needs of the project:
The Double J Trim will be used when a stronger molding is re-quired or to fill a spacing.
* Note that the entire piece is colored.
The J Trim palette will be used to cover more surface as in the case of a window that came out of the wall.
No. M01AJ Trim
No. M02ADouble J Trim
No. M03AExtended J Trim Variable
J Trim (wall installation)
Molding & FlashingProfile MS 1, MS 2 & MS Authentic
54m
m21 8"
28.6mm11
8"
22.2
mm
7 8"
15.9
mm
5 8"
28.58mm11
8"
22.2
3mm
7 8" 50.8
0mm
2"
28.6mm11
8"
25.4
mm
1"
50.8
mm
2"
VARIABLE
60.3
mm
23 8"
47.6mm17
8"
15.9m
m
5 8"
12.7mm1
2"
82
.6m
m31 4"
47.6mm17
8"
25.4
mm
1"
12.7
mm
1 2"
A
Solin d’égouttement(installation murale)
It is important to use a drip flashing over any opening to ensure water drainage.
The dual flashing will be used when a stiffer molding is re-quired or to fill a spacing.
* Note that the entire piece is colored.
The pallet drip flashing is chosen when a window or opening is too much inward toward the wall.
* Note that the entire piece is colored.
Drip flashing(wall installation)
No. M51ASimple drip flashing w/ 90degree angle
No. M50ADrip flashing
6
Variable = Degree or inch / mm Units = inch and/or mm
MACmetalarchitectural.com
Profile MS 1, MS 2 & MS Authentic
Molding & Flashing
No. M54ADouble drip flashing w/90 degree angle
No. M53ADouble drip flashing
No. M56AExtended drip flashing w/ variable
Solin d’égouttement(installation murale)
It is important to use a drip flashing over any opening to ensure water drainage.
The dual flashing will be used when a stiffer molding is re-quired or to fill a spacing.
* Note that the entire piece is colored.
The pallet drip flashing is chosen when a window or opening is too much inward toward the wall.
* Note that the entire piece is colored.
No. M57AExtended drip flashing variable w/90 degree angles
Drip flashing(wall installation)
88.9
mm
31 2"
47.6mm17
8"
25.4
mm
1"
A
76.2
mm
3"47.6mm17
8"
VARIABLE 25.4
mm
1"
57.2
mm
21 4"
47.6mm17
8"
45°
15.9m
m
5 8"
B
63.5
mm
21 2"
47.6mm17
8"
45° VARIABLE
12.7mm12"
15.9m
m
5 8"
A
7
MACmetalarchitectural.com
Variable = Degree or inch / mm Units = inch and/or mm
Profile MS 3 & 4Molding & Flashing
No. M60BRoof junction flashing (slope change) concave
Jonction mur / toit(installation toiture)
The wall / roof junction mol-ding is used when you have a roof that comes in or dies in a wall. It is available in two versions, either 90 ° or va-riable.
* Note that you must provide the required angle for the so-called variable option.
Jonction wall / roof(wall installation)
No. M61BRoof junction flashing (slope change) conex
25
.4m
m1"
76
.2m
m3"
10
1.6m
m4.0
0in
50
.8mm
2"
41.3mm1 58 "
76
.2mm
3"
VARIABLE
B
111.13mm4 38 "
50.8
0mm
2''
41.28mm15
8"
50.8
0mm
2"
25.40mm1''
25.4
0mm
1"
8
MACmetalarchitectural.com
Variable = Degree or inch / mm Units = inch and/or mm
No. M40BWall / roof w/90 degree angle junction
No. M41BWall / roof w/va-riable angle junction
Profile MS 3 & 4Molding & Flashing
Jonction mur / toit(installation toiture)
The wall / roof junction mol-ding is used when you have a roof that comes in or dies in a wall. It is available in two versions, either 90 ° or va-riable.
* Note that you must provide the required angle for the so-called variable option.
Jonction roof / wall(roofing installation)
63.5mm21
2"
123.
8mm
47 8"41
.3m
m15 8"
50.8mm2"
123.
83m
m47 8"
VARIABLE
63.50mm21
2"
41.28mm
1 58 "
50.80mm
2"
No. M21BOutside Corner w/ integrated J Trim
Coin extérieur(installation murale)
The outer corner is used to cover the junction of two outgoing walls.
Outside corner(wall installation)
41.2
8mm
15 8"
41.28mm15
8"
38.10mm11
2"
38.1
0mm
11 2"
76.55mm3.0in
76.5
5mm
3.0i
n
22.23mm7
8"
22.2
3mm
7 8"
9
Variable = Degree or inch / mm Units = inch and/or mm
MACmetalarchitectural.com
No. M22AOutside corner
No. M01BJ Trim
No. M02BDouble J Trim
No. M03BExtended J Trim
Coin intérieur(installation murale)
The inner corner is used for at the junction of two inco-ming walls.
J Trim (installation murale)
The J or J trim is used on the sides and bottom of any opening. Available in seve-ral forms depending on the needs of the project:
The Double J Trim will be used when a stronger mol-ding is required or to fill a spacing.
* Note that the entire piece is colored.
The J Trim palette will be used to cover more surface as in the case of a window that came out of the wall.
Inside corner(wall installation)
J Trim (wall installation)
Profile MS 3 & 4Molding & Flashing
50.8mm2"
41.3
mm
15 8"
41.3mm15
8"
50.8
mm
2"
22.2mm7
8"
22.2
mm
7 8"
38.1
mm
11 2"
38.1mm11
2"
53.9
8mm
21 8"41.28mm
158"
22.2
3mm
7 8"
15.8
8mm
5 8"
41.28mm15
8"
22.2
3mm
7 8" 50.8
0mm
2"
50.8
mm
2"
VARIABLE
41.3mm15
8"
25.4
mm
1"
Profile MS 3 & 4Molding & Flashing
10
MACmetalarchitectural.com
Variable = Degree or inch / mm Units = inch and/or mm
Profile MS 3 & 4Molding & Flashing
No. M59ABRoof flashing w/variable angle -1.75’’
No. M59AB Roof flashing w/variable angle -3’’
No. M58AB Roof flashing w/90 degree angle - 1.75’’
No. M58ABRoof flashing w/90 degree angle - 3’’
Roof flashing (straight or angled)
Roof flashing is the starting molding that must be ins-talled over the entire peri-meter of the roof. It is avai-lable straight or variable angle.
* Note that you must provide the required angle for the so-called variable option.
Roof flashingstraight or with angle(roofing installation)
44.4
5mm
13 4"
VARIABLE
107.9
5mm
41 4
"
25.41
mm
1.0''
12.70
mm
1 2"
76.2
0mm
3"
VARIABLE
76.20
mm
3"
25.41
mm
1''
12.70
mm
1 2"
44.4
5mm
13 4"
107.95mm41
4"
25.41mm1.0''
12.70
mm
1 2"
76.2
0mm
3"
76.20mm3"
12.70
mm
1 2"
25.41mm1.0''
11
Variable = Degree or inch / mm Units = inch and/or mm
MACmetalarchitectural.com
No. M30BVented idge cap
No. M31BNon-vented ridge cap
Faitière(installation toiture)
The ridge is applied to the junction of two outgoing roofs.
The ventilated ridge is main-ly used in the application of cathedral roof.
* Note that it is possible to make a connection between the vented and the non-ventilated mill on the site (the work must however be executed by the installer).
Ridge Cap(roof installation)
No. M32BSingle slop ridge tile
Profile MS 3 & 4Molding & Flashing
11 8
"28
.60.08 2
11 8
"28
.6
1"
25.4 3"
2"
50.8
VARIABLE
147.64mm
513
16"
50.80mm2"
63.50mm21
2"
41.2
8mm
15 8"
41.3mm
1 58 "
63.5mm
21 2"
VARIABLE
147.6mm
513
16"
50.8mm2"
12