When installing or relocating, or servicing the heat pump, use only the specied refrigerant (R410A) to charge
the refrigerant lines. Do not mix it with any other refrigerant and do not allow air to remain in the lines.
If air is mixed with the refrigerant, then it can be the cause of abnormal high pressure in the refrigerant line,
and may result in an explosion and other hazards.The use of any refrigerant other than that specied for the system will cause mechanical failure or system
malfunction or unit breakdown. In the worst case, this could lead to a serious impediment to securing product
safety.
Outdoorunit
Cylinder/
Hydrobox
Flow
temp.
controlle
r
Optionalparts
Contents
Outdoor unit. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
A-1
Cylinder unit / Hydrobox. . . . . . . . .B-1
Flow temp. controller. . . . . . . . . . . . . . .C-1
Optional parts. . . . . . . . . . . . . . . . . . . . . . . . . .D-1
http://planetaklimata.com.ua/http://planetaklimata.com.ua/ -
7/21/2019 Mitsubishi Electric Ecodan Data Book
4/322
-
7/21/2019 Mitsubishi Electric Ecodan Data Book
5/322
Contents
Outdoorunit
A-1
1 Specifications ........................................................A-2
1.1 Outdoor unit specifications ............................................... A-2
1.2 Capacity ......................................................................... A-12
1.3 Maximum outlet water temperature ............................... A-18
1.4 Available range (Water flow rate, return water temp.) .... A-20
2 Outlines and dimensions ....................................A-23
2.1 Packaged-type units ...................................................... A-23
2.2 Split-type units ............................................................... A-26
3 Wiring diagrams ...................................................A-333.1 Packaged-type units ...................................................... A-33
3.2 Split-type units ............................................................... A-37
4 Refrigerant system diagrams .............................A-47
4.1 Packaged-type units ...................................................... A-48
4.2 Split-type units ............................................................... A-49
5 Performance data ................................................A-53
5.1 Cooling performance data .............................................. A-54
5.2 Heating performance data ............................................. A-55
5.3 Part load chart ................................................................ A-63
5.4 Best COP ....................................................................... A-77
6 Noise criterion curves .........................................A-78
6.1 Packaged-type units ...................................................... A-78
6.2 Split-type units ............................................................... A-79
7 Earthquake-proof strength analysis ..................A-82
8 Error code table ...................................................A-96
9 Installation location .............................................A-97
9.1 Packaged-type units (Power inverter/Zubadan) ............. A-97
9.2 Split-type units (Power inverter) ..................................... A-99
9.3 Split-type units (Mr.SLIM+)........................................... A-101
9.4 Split-type units (Zubadan) ............................................ A-103
Outdoor unit
-
7/21/2019 Mitsubishi Electric Ecodan Data Book
6/322
O
td
it
A-2
Specifications1 Outdoor unit
1.1 Outdoor unit specifications(1) Packaged-type units
Power inverter
Model Name PUHZ-W50VHA(-BS) PUHZ-W85VHA2(-BS)
Power supply (phase, cycle, voltage) 1, 230V, 50Hz 1, 230V, 50Hz
Max. current A 13.0 23.0
Breaker size A 16 25
Outer casing Galvanized plate Galvanized plate
External finish Munsell 3Y 7.8/1.1 Munsell 3Y 7.8/1.1
Refrigerant control Linear expansion valve Linear expansion valve
Compressor Hermetic twin rotary Hermetic twin rotary
Model SNB130FGCM TNB220FLHM1T
Motor output kW 0.9 1.3
Start type Inverter Inverter
Protection devices
HP switch
Discharge thermoComp. Surface thermo
HP switch
Discharge thermoComp. Surface thermo
Oil (Model) L 0.35 (FV50S) 0.67 (FV50S)
Crankcase heater W - -
Heat exchanger Air Plate fin coil Plate fin coil
Water Plate heat exchanger Plate heat exchanger
Fan Fan(drive) x No. Propeller fan x 1 Propeller fan x 1
Fan motor output kW 0.086 0.074
Air flow m3/min(CFM) 50 (1,760) 49 (1,730)
Defrost method Reverse cycle Reverse cycle
Noise level (SPL) Heating dB(A) 46 48
Cooling dB(A) 45 48
Noise level (PWL) Heating dB(A) 61 66
Dimensions Width mm(in) 950 (37-3/8) 950 (37-3/8)
Depth mm(in) 330+30 (13+1-3/16) 330+30 (13+1-3/16)
Height mm(in) 740 (29-3/16) 943 (37-1/8)
Weight kg(lbs) 64 (141) 79 (174)
Refrigerant R410A R410A
Quantity kg(lbs) 1.7 (3.7) 2.4 (5.3)
Pipe size O.D. Liquid mm(in) - -
Gas mm(in) - -
Connection method - -
Between the indoor &outdoor unit
Height difference m - -
Piping length m - -
Guaranteed operatingrange (Outdoor)
Heating C -15 ~ +35 -20 ~ +35
Cooling C -5 ~ +46 -5 ~ +46
Outlet water temp.(Max in heating, Min in cooling)
Heating C +60 +60
Cooling C +5 +5
Nominal return watertemperature range
Heating C +9 ~ +59 +9 ~ +59
Cooling C +8 ~ +28 +8 ~ +28
Water flow rate range L/min 6.5 ~ 14.3 10.0 ~ 25.8
-
7/21/2019 Mitsubishi Electric Ecodan Data Book
7/322
Outdoorunit
A-3
Specifications1 Outdoor unit
Zubadan
Model Name PUHZ-HW112YHA2(-BS) PUHZ-HW140VHA2(-BS) PUHZ-HW140YHA2(-BS)
Power supply (phase, cycle, voltage) 3, 400V, 50Hz 1, 230V, 50Hz 3, 400V, 50Hz
Max. current A 13.0 35.0 13.0
Breaker size A 16 40 16
Outer casing Galvanized plate Galvanized plate Galvanized plate
External finish Munsell 3Y 7.8/1.1 Munsell 3Y 7.8/1.1 Munsell 3Y 7.8/1.1
Refrigerant control Linear expansion valve Linear expansion valve Linear expansion valve
Compressor Hermetic scroll Hermetic scroll Hermetic scroll
Model ANB33FJFMT ANB42FJGMT ANB42FJFMT
Motor output kW 2.5 3.0 3.0
Start type Inverter Inverter Inverter
Protection devices HP switchLP switch
Discharge thermoComp. Surface thermo
HP switchLP switch
Discharge thermoComp. Surface thermo
HP switchLP switch
Discharge thermoComp. Surface thermo
Oil (Model) L 0.9 (FV50S) 0.9 (FV50S) 0.9 (FV50S)
Crankcase heater W - - -
Heat exchanger Air Plate fin coil Plate fin coil Plate fin coil
Water Plate heat exchanger Plate heat exchanger Plate heat exchanger
Fan Fan(drive) x No. Propeller fan x 2 Propeller fan x 2 Propeller fan x 2
Fan motor output kW 0.074 x 2 0.074 x 2 0.074 x 2
Air flow m3/min(CFM)
100 (3,350) 100 (3,350) 100 (3,350)
Defrost method Reverse cycle Reverse cycle Reverse cycle
Noise level (SPL) Heating dB(A) 53 53 53Cooling dB(A) 53 53 53
Noise level (PWL) Heating dB(A) 67 67 67
Dimensions Width mm(in) 1020 (40-3/16) 1020 (40-3/16) 1020 (40-3/16)
Depth mm(in) 330+30 (13+1-3/16) 330+30 (13+1-3/16) 330+30 (13+1-3/16)
Height mm(in) 1350 (53-1/8) 1350 (53-1/8) 1350 (53-1/8)
Weight kg(lbs) 148 (327) 134 (296) 148 (327)
Refrigerant R410A R410A R410A
Quantity kg(lbs) 4.0 (8.8) 4.3 (9.5) 4.3 (9.5)
Pipe size O.D. Liquid mm(in) - - -
Gas mm(in) - - -
Connection method - - -
Between the indoor &outdoor unit
Heightdifference
m - - -
Pipinglength
m - - -
Guaranteed operatingrange (Outdoor)
Heating C -25 ~ +35 -25 ~ +35 -25 ~ +35
Cooling C -5 ~ +46 -5 ~ +46 -5 ~ +46
Outlet water temp.(Max in heating, Min in cooling)
Heating C +60 +60 +60
Cooling C +5 +5 +5
Nominal return water
temperature range
Heating C +11 ~ +59 +10 ~ +59 +10 ~ +59
Cooling C +8 ~ +28 +8 ~ +28 +8 ~ +28
Water flow rate range L/min 14.4 ~ 32.1 17.9 ~ 40.1 17.9 ~ 40.1
-
7/21/2019 Mitsubishi Electric Ecodan Data Book
8/322
O
td
it
A-4
Specifications1 Outdoor unit
(2) Split-type units
Power inverter
Model Name PUHZ-SW40VHA(-BS) PUHZ-SW50VHA(-BS)
Power supply (phase, cycle, voltage) 1, 230V, 50Hz 1, 230V, 50Hz
Max. current A 13.0 13.0
Breaker size A 16 16
Outer casing Galvanized plate Galvanized plate
External finish Munsell 3Y 7.8/1.1 Munsell 3Y 7.8/1.1
Refrigerant control Linear expansion valve Linear expansion valve
Compressor Hermetic twin rotary Hermetic twin rotary
Model SNB130FGCM2 SNB130FGCM2
Motor output kW 0.9 0.9
Start type Inverter Inverter
Protection devices
HP switch
Discharge thermo
Comp. Surface thermo
HP switch
Discharge thermo
Comp. Surface thermo
Oil (Model) L 0.5(FV50S) 0.5(FV50S)
Crankcase heater W - -
Heat exchanger Air Plate fin coil Plate fin coil
Water - -
Fan Fan(drive) x No. Propeller fan Propeller fan
Fan motor output kW 0.04 0.04
Air flow m3/min(CFM) 35 (1,240) 35 (1,240)
Defrost method Reverse cycle Reverse cycle
Noise level (SPL) Heating dB(A) 45 46
Cooling dB(A) 45 46
Noise level (PWL) Heating dB(A) 62 63
Dimensions Width mm(in) 800 (31-1/2) 800 (31-1/2)
Depth mm(in) 300+23 (11-13/16+7/8) 300+23 (11-13/16+7/8)
Height mm(in) 600 (23-5/8) 600 (23-5/8)
Weight kg(lbs) 42 (93) 42 (93)
Refrigerant R410A R410A
Quantity kg(lbs) 2.1 (4.6) 2.1 (4.6)
Pipe size O.D. Liquid mm(in) 6.35 (1/4) 6.35 (1/4)
Gas mm(in) 12.7 (1/2) 12.7 (1/2)
Connection method Flared Flared
Between the indoor &outdoor unit
Height difference m Max. 10 Max. 10
Piping length m Max. 40 Max. 40
Guaranteed operatingrange (Outdoor)
Heating C -15 ~ +21 -15 ~ +21
DHW C -15 ~ +35 -15 ~ +35
Cooling C -5 ~ +46 -5 ~ +46
Outlet water temp.(Max in heating, Min in cooling)
Heating C +60 +60
Cooling C +5 +5
Nominal return watertemperature range
Heating C +9 ~ +59 +9 ~ +59
Cooling C +8 ~ +28 +8 ~ +28
Water flow rate range L/min 7.1 ~ 11.8 7.1 ~ 17.2
-
7/21/2019 Mitsubishi Electric Ecodan Data Book
9/322
Outdoorunit
A-5
Specifications1 Outdoor unit
Model Name PUHZ-SW75VHA(-BS)
Power supply (phase, cycle, voltage) 1, 230V, 50Hz
Max. current A 19.0
Breaker size A 25
Outer casing Galvanized plate
External finish Munsell 3Y 7.8/1.1
Refrigerant control Linear expansion valve
Compressor Hermetic twin rotary
Model TNB220FLHMT
Motor output kW 1.3
Start type Inverter
Protection devices
HP switch
Discharge thermo
Comp. Surface thermo
Oil (Model) L 0.87 (FV50S)
Crankcase heater W -
Heat exchanger Air Plate fin coil
Water -
Fan Fan(drive) x No. Propeller fan
Fan motor output kW 0.074
Air flow m3/min(CFM) 55 (1,940)
Defrost method Reverse cycle
Noise level (SPL) Heating dB(A) 51
Cooling dB(A) 48
Noise level (PWL) Heating dB(A) 69Dimensions Width mm(in) 950 (37-3/8)
Depth mm(in) 330+30 (13+1-3/16)
Height mm(in) 943 (37-1/8)
Weight kg(lbs) 75 (166)
Refrigerant R410A
Quantity kg(lbs) 3.2(7.0)
Pipe size O.D. Liquid mm(in) 9.52 (3/8)
Gas mm(in) 15.88 (5/8)
Connection method Flared
Between the indoor &outdoor unit
Height difference m Max. 10
Piping length m Max. 40
Guaranteed operatingrange (Outdoor)
Heating C -20 ~ +21
DHW C -20 ~ +35
Cooling C -5 ~ +46
Outlet water temp.(Max in heating, Min in cooling)
Heating C +60
Cooling C +5
Nominal return watertemperature range
Heating C +11 ~ +59
Cooling C +8 ~ +28
Water flow rate range L/min 10.2 ~ 22.9
-
7/21/2019 Mitsubishi Electric Ecodan Data Book
10/322
O
td
it
A-6
Specifications1 Outdoor unit
Model Name PUHZ-SW100VHA(-BS) PUHZ-SW100YHA(-BS)
Power supply (phase, cycle, voltage) 1, 230V, 50Hz 3, 400V, 50Hz
Max. current A 29.5 13.0
Breaker size A 32 16
Outer casing Galvanized plate Galvanized plate
External finish Munsell 3Y 7.8/1.1 Munsell 3Y 7.8/1.1
Refrigerant control Linear expansion valve Linear expansion valve
Compressor Hermetic scroll Hermetic scroll
Model ANB33FNEMT ANB33FNDMT
Motor output kW 2.5 2.5
Start type Inverter Inverter
Protection devices HP switch
LP switch
Discharge thermo
Comp. Surface thermo
HP switch
LP switch
Discharge thermo
Comp. Surface thermo
Oil (Model) L 1.40 (FV50S) 1.40 (FV50S)
Crankcase heater W - -Heat exchanger Air Plate fin coil Plate fin coil
Water - -
Fan Fan(drive) x No. Propeller fan 2 Propeller fan 2
Fan motor output kW 0.074 2 0.074 2
Air flow m3/min(CFM)
100 (3,350) 100 (3,350)
Defrost method Reverse cycle Reverse cycle
Noise level (SPL)Heating dB(A) 54 54
Cooling dB(A) 50 50
Noise level (PWL) Heating dB(A) 70 70
Dimensions Width mm(in) 950 (37-3/8) 950 (37-3/8)
Depth mm(in) 330+30 (13+1-3/16) 330+30 (13+1-3/16)
Height mm(in) 1350 (53-1/8) 1350 (53-1/8)
Weight kg(lbs) 118(261) 130 (287)
Refrigerant R410A R410A
Quantity kg(lbs) 4.6 (10.2) 4.6 (10.2)
Pipe size O.D. Liquid mm(in) 9.52 (3/8) 9.52 (3/8)
Gas mm(in) 15.88 (5/8) 15.88 (5/8)
Connection method Flared Flared
Between the indoor &outdoor unit
Height
difference
m Max. 30 Max. 30
Pipinglength
m Max. 75 Max. 75
Guaranteed operatingrange (Outdoor)
Heating C -20 ~ +21 -20 ~ +21
DHW C -20 ~ +35 -20 ~ +35
Cooling C -5 ~ +46 -5 ~ +46
Outlet water temp.(Max in heating, Min in cooling)
Heating C +60 +60
Cooling C +5 +5
Nominal return watertemperature range
Heating C +10 ~ +59 +10 ~ +59
Cooling C +8 ~ +28 +8 ~ +28
Water flow rate range L/min 14.4 ~ 32.1 14.4 ~ 32.1
-
7/21/2019 Mitsubishi Electric Ecodan Data Book
11/322
Outdoorunit
A-7
Specifications1 Outdoor unit
Model Name PUHZ-SW120VHA(-BS) PUHZ-SW120YHA(-BS)
Power supply (phase, cycle, voltage) 1, 230V, 50Hz 3, 400V, 50Hz
Max. current A 29.5 13.0
Breaker size A 32 16
Outer casing Galvanized plate Galvanized plate
External finish Munsell 3Y 7.8/1.1 Munsell 3Y 7.8/1.1Refrigerant control Linear expansion valve Linear expansion valve
Compressor Hermetic scroll Hermetic scroll
Model ANB42FNEMT ANB42FNDMT
Motor output kW 3.0 3.0
Start type Inverter Inverter
Protection devices HP switch
LP switch
Discharge thermo
Comp. Surface thermo
HP switch
LP switch
Discharge thermo
Comp. Surface thermo
Oil (Model) L 1.40 (FV50S) 1.40 (FV50S)
Crankcase heater W - -Heat exchanger Air Plate fin coil Plate fin coil
Water - -
Fan Fan(drive) x No. Propeller fan 2 Propeller fan 2
Fan motor output kW 0.074 2 0.074 2
Air flow m3/min(CFM)
100 (3,350) 100 (3,350)
Defrost method Reverse cycle Reverse cycle
Noise level (SPL)Heating dB(A) 54 54
Cooling dB(A) 51 51
Noise level (PWL) Heating dB(A) 72 72
Dimensions Width mm(in) 950 (37-3/8) 950 (37-3/8)
Depth mm(in) 330+30 (13+1-3/16) 330+30 (13+1-3/16)
Height mm(in) 1350 (53-1/8) 1350 (53-1/8)
Weight kg(lbs) 118(261) 130 (287)
Refrigerant R410A R410A
Quantity kg(lbs) 4.6 (10.2) 4.6 (10.2)
Pipe size O.D. Liquid mm(in) 9.52 (3/8) 9.52 (3/8)
Gas mm(in) 15.88 (5/8) 15.88 (5/8)
Connection method Flared Flared
Between the indoor &outdoor unit
Height
difference
m Max. 30 Max. 30
Pipinglength
m Max. 75 Max. 75
Guaranteed operatingrange (Outdoor)
Heating C -20 ~ +21 -20 ~ +21
DHW C -20 ~ +35 -20 ~ +35
Cooling C -5 ~ +46 -5 ~ +46
Outlet water temp.(Max in heating, Min in cooling)
Heating C +60 +60
Cooling C +5 +5
Nominal return watertemperature range
Heating C +10 ~ +59 +10 ~ +59
Cooling C +8 ~ +28 +8 ~ +28
Water flow rate range L/min 20.1 ~ 45.9 20.1 ~ 45.9
-
7/21/2019 Mitsubishi Electric Ecodan Data Book
12/322
O
td
it
A-8
Specifications1 Outdoor unit
Model Name PUHZ-RP200YKA PUHZ-RP250YKA
Power supply (phase, cycle, voltage) 3, 400V, 50Hz 3, 400V, 50Hz
Max. current A 19.0 21.0
Breaker size A 32 32
Outer casing Galvanized plate Galvanized plateExternal finish Munsell 3Y 7.8/1.1 Munsell 3Y 7.8/1.1
Refrigerant control Linear expansion valve Linear expansion valve
Compressor Hermetic scroll Hermetic scroll
Model ANB52FFPMT ANB66FFZMT
Motor output kW 4.7 5.5
Start type Inverter Inverter
Protection devicesHP switch
Discharge thermoComp. Surface thermo
HP switchDischarge thermo
Comp. Surface thermo
Oil (Model) L 2.30 (FV50S) 2.30 (FV50S)
Crankcase heater W - -
Heat exchanger Air Plate fin coil Plate fin coil
Water - -
Fan Fan(drive) x No. Propeller fan x 2 Propeller fan x 2
Fan motor output kW 0.150 x 2 0.150 x 2
Air flow m3/min(CFM) 140 (4,940) 140 (4,940)
Defrost method Reverse cycle Reverse cycle
Noise level (SPL) Heating dB 59 59
Cooling dB 58 58
Noise level (PWL) dB 76 76
Dimensions Width mm(in) 1050 (41-5/16) 1050 (41-5/16)Depth mm(in) 330+30 (13+1-3/16) 330+30 (13+1-3/16)
Height mm(in) 1338 (52-11/16) 1338 (52-11/16)
Weight kg(lbs) 135 (297) 141 (311)
Refrigerant R410A R410A
Quantity kg(lbs) 7.1 (15.7) 7.7 (17.0)
Pipe size O.D. Liquid mm(in) 9.52 (3/8) 12.7 (1/2)
Gas mm(in) 25.4 (1) 25.4 (1)
Connection method Flared Flared
Between the indoor &outdoor unit
Height difference m Max. 30 Max. 30
Piping length m Max. 120 Max. 120
Guaranteed operatingrange (Outdoor)
Heating C -20 ~ +35 -20 ~ +35
Cooling C -5 ~ +46 -5 ~ +46
Outlet water temp.(Max in heating, Min in cooling)
Heating C +53 +53
Cooling C +5 +5
Nominal return watertemperature range
Heating C +10 ~ +52 +10 ~ +52
Cooling C +8 ~ +28 +8 ~ +28
Water flow rate range L/min 27.3 ~ 64.2 32.1 ~ 80.3
-
7/21/2019 Mitsubishi Electric Ecodan Data Book
13/322
Outdoorunit
A-9
Specifications1 Outdoor unit
Mr.SLIM+
Model Name PUHZ-FRP71VHA
Power supply (phase, cycle, voltage) 1, 230V, 50Hz
Max. current A 19.0
Breaker size A 25
Outer casing Galvanized plateExternal finish Munsell 3Y 7.8/1.1
Refrigerant control Linear expansion valve
Compressor Hermetic
Model SNB172FSHM1
Motor output kW 1.6
Start type Inverter
Protection devicesHP switch
Discharge thermoComp. Surface thermo
Oil (Model) L 0.70 (FV50S)
Crankcase heater W -
Heat exchanger Air Plate fin coil
Water -
Fan Fan(drive) x No. Propeller fan x 1
Fan motor output kW 0.086
Air flow m3/min(CFM) 55 (1,940)
Defrost method Reverse cycle
Noise level (SPL) ATA Cooling
HR CoolingdB 47
ATA Heating
ATW HeatingdB 48
Noise level (PWL) ATA Cooling
HR CoolingdB 67
ATA Heating
ATW HeatingdB 68
Dimensions Width mm(in) 950 (37-3/8)
Depth mm(in) 330+30 (13+1-3/16)
Height mm(in) 943 (37-1/8)
Weight kg(lbs) 73 (161)
Refrigerant R410A
Quantity kg(lbs) 3.8 (8.4)
Pipe size O.D. ATA Liquid mm(in) 9.52 (3/8)
Gas mm(in) 15.88 (5/8)
ATW Liquid mm(in) 9.52 (3/8)
Gas mm(in) 15.88 (5/8)
Connection method Flared
Between the indoor &outdoor unit
Height difference m Max. 20
Piping length m Max. 60m total, Max. 30m for each
Guaranteed operatingrange (Outdoor)
ATA Cooling C -5 ~ +46
ATA Heating C -20 ~ +21
ATW Heating C -20 ~ +35
HR Cooling C +15 ~ +46
Outlet water temp.(Max in heating)
ATW Heating C +60
Nominal return watertemperature range
ATW Heating C +11 ~ +59
Water flow rate range L/min 11.5 ~ 22.9
-
7/21/2019 Mitsubishi Electric Ecodan Data Book
14/322
O
td
it
A-10
Specifications1 Outdoor unit
Zubadan
Model Name PUHZ-SHW80VHA PUHZ-SHW112VHA PUHZ-SHW112YHA
Power supply (phase, cycle, voltage) 1, 230V, 50Hz 1, 230V, 50Hz 3, 400V, 50Hz
Max. current A 29.5 35.0 13.0
Breaker size A 32 40 16
Outer casing Galvanized plate Galvanized plate Galvanized plateExternal finish Munsell 3Y 7.8/1.1 Munsell 3Y 7.8/1.1 Munsell 3Y 7.8/1.1
Refrigerant control Linear expansion valve Linear expansion valve Linear expansion valve
Compressor Hermetic scroll Hermetic scroll Hermetic scroll
Model ANB33FJMMT ANB33FJMMT ANB33FJLMT
Motor output kW 2.5 2.5 2.5
Start type Inverter Inverter Inverter
Protection devices HP switch
LP switch
Discharge thermo
Comp. Surface thermo
HP switch
LP switch
Discharge thermo
Comp. Surface thermo
HP switch
LP switch
Discharge thermo
Comp. Surface thermo
Oil (Model) L 1.40 (FV50S) 1.40 (FV50S) 1.40 (FV50S)Crankcase heater W - - -
Heat exchanger Air Plate fin coil Plate fin coil Plate fin coil
Water - - -
Fan Fan(drive) x No. Propeller fan 2 Propeller fan 2 Propeller fan 2
Fan motor output kW 0.074 2 0.074 2 0.074 2
Air flow m3/min(CFM)
100 (3,350) 100 (3,350) 100 (3,350)
Defrost method Reverse cycle Reverse cycle Reverse cycle
Noise level (SPL)Heating dB(A) 51 52 52
Cooling dB(A) 50 51 51
Noise level (PWL) Heating dB(A) 69 70 70
Dimensions Width mm(in) 950 (37-3/8) 950 (37-3/8) 950 (37-3/8)
Depth mm(in) 330+30 (13+1-3/16) 330+30 (13+1-3/16) 330+30 (13+1-3/16)
Height mm(in) 1350 (53-1/8) 1350 (53-1/8) 1350 (53-1/8)
Weight kg(lbs) 120 (265) 120 (265) 134 (296)
Refrigerant R410A R410A R410A
Quantity kg(lbs) 5.5 (12.1) 5.5 (12.1) 5.5 (12.1)
Pipe size O.D. Liquid mm(in) 9.52 (3/8) 9.52 (3/8) 9.52 (3/8)
Gas mm(in) 15.88 (5/8) 15.88 (5/8) 15.88 (5/8)
Connection method Flared Flared Flared
Between the indoor &outdoor unit
Heightdifference
m Max. 30 Max. 30 Max. 30
Pipinglength
m Max. 75 Max. 75 Max. 75
Guaranteed operatingrange (Outdoor)
Heating C -25 ~ +21 -25 ~ +21 -25 ~ +21
DHW C -25 ~ +35 -25 ~ +35 -25 ~ +35
Cooling C -5 ~ +46 -5 ~ +46 -5 ~ +46
Outlet water temp.(Max in heating, Min in cooling)
Heating C +60 +60 +60
Cooling C +5 +5 +5
Nominal return watertemperature range
Heating C +10 ~ +59 +10 ~ +59 +10 ~ +59
Cooling C +8 ~ +28 +8 ~ +28 +8 ~ +28
Water flow rate range L/min 10.2 ~ 22.9 14.4 ~ 32.1 14.4 ~ 32.1
-
7/21/2019 Mitsubishi Electric Ecodan Data Book
15/322
Outdoorunit
A-11
Specifications1 Outdoor unit
Model Name PUHZ-SHW140YHA PUHZ-SHW230YKA
Power supply (phase, cycle, voltage) 3, 400V, 50Hz 3, 400V, 50Hz
Max. current A 13.0 26.0
Breaker size A 16 32
Outer casing Galvanized plate Galvanized plate
External finish Munsell 3Y 7.8/1.1 Munsell 3Y 7.8/1.1
Refrigerant control Linear expansion valve Linear expansion valve
Compressor Hermetic scroll Hermetic scroll
Model ANB33FJLMT ANB66FJNMT
Motor output kW 2.5 4.7
Start type Inverter Inverter
Protection devices
HP switch
LP switch
Discharge thermo
Comp. Surface thermo
HP switch
LP switch
Discharge thermo
Comp. Surface thermo
Oil (Model) L 1.40 (FV50S) 1.70 (FV50S)
Crankcase heater W - -Heat exchanger Air Plate fin coil Plate fin coil
Water - -
Fan Fan(drive) x No. Propeller fan 2 Propeller fan 2
Fan motor output kW 0.074 2 0.150 2
Air flow m3/min(CFM) 100 (3,350) 140 (4,940)
Defrost method Reverse cycle Reverse cycle
Noise level (SPL) Heating dB(A) 52 59
Cooling dB(A) 51 58
Noise level (PWL) Heating dB(A) 70 75
Dimensions Width mm(in) 950 (37-3/8) 1050 (41-5/16)
Depth mm(in) 330+30 (13+1-3/16) 330+30 (13+1-3/16)
Height mm(in) 1350 (53-1/8) 1338 (52-11/16)
Weight kg(lbs) 134 (296) 148 (327)
Refrigerant R410A R410A
Quantity kg(lbs) 5.5 (12.1) 7.1 (15.7)
Pipe size O.D. Liquid mm(in) 9.52 (3/8) 9.52 (3/8)
Gas mm(in) 15.88 (5/8) 25.4 (1)
Connection method Flared Flared
Between the indoor &outdoor unit
Height difference m Max. 30 Max. 30
Piping length m Max. 75 Max. 80
Guaranteed operatingrange (Outdoor)
Heating C -25 ~ +21 -25 ~ +21
DHW C -25 ~ +35 -25 ~ +35
Cooling C -5 ~ +46 -5 ~ +46
Outlet water temp.(Max in heating, Min in cooling)
Heating C +60 +60
Cooling C +5 +5
Nominal return watertemperature range
Heating C +10 ~ +59 +10 ~ +59
Cooling C +8 ~ +28 +8 ~ +28
Water flow rate range L/min 17.9 ~ 40.1 28.7 ~ 65.9
-
7/21/2019 Mitsubishi Electric Ecodan Data Book
16/322
O
td
it
A-12
Specifications1 Outdoor unit
1.2 Capacity(1) Packaged-type units
Power inverter
Zubadan
Model name PUHZ-W50VHA(-BS) PUHZ-W85VHA2(-BS)
Nominal water flow rate (Heating mode) L/min 14.30 25.80
Heating(A7/W35)
Capacity kW 5.00 9.00
COP 4.10 4.18
Power input kW 1.22 2.15
Heating
(A2/W35)Capacity kW 5.00 8.50
COP 3.13 3.17
Power input kW 1.60 2.68
Pressure difference (water circuit) kPa 12 13.5
Heating pump input (based on EN14511) kW 0.01 0.02
Nominal water flow rate (Cooling mode) L/min 12.90 21.50
Cooling
(A35/W7)
Capacity kW 4.50 7.50
EER (COP) 2.94 2.47Power input kW 1.53 3.04
Cooling
(A35/W18)Capacity kW 4.50 7.50
EER (COP) 4.13 3.93
Power input kW 1.09 1.91
Pressure difference (water circuit) kPa 10 10
Cooling pump input (based on EN14511) kW 0.01 0.01
Recommended plate heat exchanger Built-in Built-in
Note: "COP" and "Power input" in the above table are values that contains the "pump input (based on EN 14511) ".
Model name PUHZ-HW112YHA2(-BS) PUHZ-HW140V/YHA2(-BS)
Nominal water flow rate (Heating mode) L/min 32.10 40.10
Heating
(A7/W35)Capacity kW 11.20 14.00
COP 4.42 4.25
Power input kW 2.53 3.29
Heating
(A2/W35)Capacity kW 11.20 14.00
COP 3.11 3.11
Power input kW 3.60 4.50
Pressure difference (water circuit) kPa 6 9
Heating pump input (based on EN14511) kW 0.01 0.02
Nominal water flow rate (Cooling mode) L/min 28.70 35.80
Cooling
(A35/W7)Capacity kW 10.00 12.50
EER (COP) 2.78 2.50
Power input kW 3.60 5.00
Cooling
(A35/W18)Capacity kW 10.00 12.50
EER (COP) 4.10 3.60
Power input kW 2.44 3.47
Pressure difference (water circuit) kPa 5 7
Cooling pump input (based on EN14511) kW 0.01 0.02
Recommended plate heat exchanger Built-in Built-in
Note: "COP" and "Power input" in the above table are values that contains the "pump input (based on EN 14511) ".
-
7/21/2019 Mitsubishi Electric Ecodan Data Book
17/322
Outdoorunit
A-13
Specifications1 Outdoor unit
(2) Split-type units
Power inverter
Model name PUHZ-SW40VHA(-BS) PUHZ-SW50VHA(-BS)
Nominal water flow rate (Heating mode) L/min 11.80 17.20
Heating(A7/W35)
Capacity kW 4.10 6.00
COP 4.80 4.42
Power input kW 0.85 1.36
Heating
(A2/W35)Capacity kW 4.00 5.00
COP 3.24 2.97
Power input kW 1.24 1.68
Pressure difference (water circuit) kPa - -
Heating pump input (based on EN14511) kW - -
Nominal water flow rate (Cooling mode) L/min 10.30 12.90
Cooling
(A35/W7)
Capacity kW 3.60 4.50
EER (COP) 2.71 2.38Power input kW 1.33 1.89
Cooling
(A35/W18)Capacity kW 3.60 5.00
EER (COP) 4.65 3.96
Power input kW 0.77 1.26
Pressure difference (water circuit) kPa - -
Cooling pump input (based on EN14511) kW - -
Recommended plate heat exchanger ACH70-40 ACH70-40
The table shows performance data obtained when a plate heat exchanger is connected.
Model name PUHZ-SW75VHA(-BS)
Nominal water flow rate (Heating mode) L/min 22.90
Heating
(A7/W35)Capacity kW 8.00
COP 4.40
Power input kW 1.82
Heating
(A2/W35)Capacity kW 7.50
COP 3.40
Power input kW 2.21
Pressure difference (water circuit) kPa -
Heating pump input (based on EN14511) kW -
Nominal water flow rate (Cooling mode) L/min 18.90
Cooling
(A35/W7)Capacity kW 6.60
EER (COP) 2.55
Power input kW 2.59
Cooling
(A35/W18)Capacity kW 7.10
EER (COP) 4.01
Power input kW 1.77
Pressure difference (water circuit) kPa -
Cooling pump input (based on EN14511) kW -
Recommended plate heat exchanger ACH70-40
The table shows performance data obtained when a plate heat exchanger is connected.
-
7/21/2019 Mitsubishi Electric Ecodan Data Book
18/322
O
td
it
A-14
Specifications1 Outdoor unit
Model name PUHZ-SW100VHA(-BS) PUHZ-SW100YHA(-BS)
Nominal water flow rate (Heating mode) L/min 32.10 32.10
Heating(A7/W35)
Capacity kW 11.20 11.20
COP 4.45 4.45
Power input kW 2.52 2.52
Heating
(A2/W35)Capacity kW 10.00 10.00
COP 3.32 3.32
Power input kW 3.01 3.01
Pressure difference (water circuit) kPa - -
Heating pump input (based on EN14511) kW - -
Nominal water flow rate (Cooling mode) L/min 26.10 26.10
Cooling
(A35/W7)Capacity kW 9.10 9.10
EER (COP) 2.75 2.75Power input kW 3.31 3.31
Cooling
(A35/W18)Capacity kW 10.00 10.00
EER (COP) 4.35 4.35
Power input kW 2.30 2.30
Pressure difference (water circuit) kPa - -
Cooling pump input (based on EN14511) kW - -
Recommended plate heat exchanger ACH70-40 ACH70-40
The table shows performance data obtained when a plate heat exchanger is connected.
Model name PUHZ-SW120VHA(-BS) PUHZ-SW120YHA(-BS)
Nominal water flow rate (Heating mode) L/min 45.90 45.90
Heating
(A7/W35)
Capacity kW 16.00 16.00
COP 4.10 4.10
Power input kW 3.90 3.90
Heating
(A2/W35)Capacity kW 12.00 12.00
COP 3.24 3.24
Power input kW 3.70 3.70
Pressure difference (water circuit) kPa - -
Heating pump input (based on EN14511) kW - -
Nominal water flow rate (Cooling mode) L/min 35.80 35.80
Cooling
(A35/W7)Capacity kW 12.50 12.50
EER (COP) 2.32 2.32
Power input kW 5.30 5.30
Cooling
(A35/W18)Capacity kW 14.00 14.00
EER (COP) 4.08 4.08
Power input kW 3.43 3.43
Pressure difference (water circuit) kPa - -
Cooling pump input (based on EN14511) kW - -
Recommended plate heat exchanger ACH70-40 ACH70-40
The table shows performance data obtained when a plate heat exchanger is connected.
-
7/21/2019 Mitsubishi Electric Ecodan Data Book
19/322
Outdoorunit
A-15
Specifications1 Outdoor unit
Model name PUHZ-RP200YKA PUHZ-RP250YKA
Nominal water flow rate (Heating mode) L/min 64.2 80.3
Heating
(A7/W35)Capacity kW 22.40 27.00
COP 3.73 3.39
Power input kW 6.01 7.97
Heating
(A2/W35)Capacity kW 17.50 19.20
COP 2.66 2.53
Power input kW 6.57 7.60
Pressure difference (water circuit) kPa - -
Heating pump input (based on EN14511) kW - -
Nominal water flow rate (Cooling mode) L/min 54.5 64.2
Cooling
(A35/W7)Capacity kW 18.50 20.60
EER (COP) 2.31 1.90
Power input kW 8.00 10.87
Cooling(A35/W18)
Capacity kW 19.00 25.00EER (COP) 3.78 3.10
Power input kW 5.02 8.07
Pressure difference (water circuit) kPa - -
Cooling pump input (based on EN14511) kW - -
Recommended plate heat exchangerACH70-40 x 2
Parallel connectionACH70-40 x 2
Parallel connection
The table shows performance data obtained when a plate heat exchanger is connected.
Model name PUHZ-FRP71VHA
Nominal water flow rate (Heating mode) L/min 22.90
Heating
(A7/W35)Capacity kW 8.00
COP 4.08
Power input kW 1.96
Heating
(A2/W35)Capacity kW 7.50
COP 2.83
Power input kW 2.65
Pressure difference (water circuit) kPa -
Heating pump input (based on EN14511) kW -
Recommended plate heat exchanger ACH70-40
The table shows performance data obtained when a plate heat exchanger is connected.
Mr.SLIM+
-
7/21/2019 Mitsubishi Electric Ecodan Data Book
20/322
O
td
it
A-16
Specifications1 Outdoor unit
Zubadan
Model name PUHZ-SHW80VHA PUHZ-SHW112VHA
Nominal water flow rate (Heating mode) L/min 22.90 32.10
Heating
(A7/W35)Capacity kW 8.00 11.20
COP 4.65 4.46
Power input kW 1.72 2.51Heating
(A2/W35)Capacity kW 8.00 11.20
COP 3.55 3.34
Power input kW 2.25 3.35
Pressure difference (water circuit) kPa - -
Heating pump input (based on EN14511) kW - -
Nominal water flow rate (Cooling mode) L/min 20.40 28.70
Cooling
(A35/W7)Capacity kW 7.10 10.00
EER (COP) 3.31 2.83
Power input kW 2.15 3.53
Cooling(A35/W18)
Capacity kW 7.10 10.00EER (COP) 4.52 4.74
Power input kW 1.57 2.11
Pressure difference (water circuit) kPa - -
Cooling pump input (based on EN14511) kW - -
Recommended plate heat exchanger ACH70-40 ACH70-40
The table shows performance data obtained when a plate heat exchanger is connected.
Model name PUHZ-SHW112YHA PUHZ-SHW140YHA
Nominal water flow rate (Heating mode) L/min 32.10 40.10
Heating
(A7/W35)Capacity kW 11.20 14.00
COP 4.46 4.22
Power input kW 2.51 3.32
Heating
(A2/W35)Capacity kW 11.20 14.00
COP 3.34 2.96
Power input kW 3.35 4.73
Pressure difference (water circuit) kPa - -
Heating pump input (based on EN14511) kW - -
Nominal water flow rate (Cooling mode) L/min 28.70 35.80
Cooling
(A35/W7)Capacity kW 10.00 12.50
EER (COP) 2.83 2.17
Power input kW 3.53 5.76
Cooling
(A35/W18)Capacity kW 10.00 12.50
EER (COP) 4.74 4.26
Power input kW 2.11 2.93
Pressure difference (water circuit) kPa - -
Cooling pump input (based on EN14511) kW - -
Recommended plate heat exchanger ACH70-40 ACH70-40
The table shows performance data obtained when a plate heat exchanger is connected.
-
7/21/2019 Mitsubishi Electric Ecodan Data Book
21/322
Outdoorunit
A-17
Specifications1 Outdoor unit
Model name PUHZ-SHW230YKA
Nominal water flow rate (Heating mode) L/min 65.90
Heating
(A7/W35)
Capacity kW 23.00
COP 3.65
Power input kW 6.30
Heating(A2/W35)
Capacity kW 23.00
COP 2.37
Power input kW 9.71
Pressure difference (water circuit) kPa -
Heating pump input (based on EN14511) kW -
Nominal water flow rate (Cooling mode) L/min 57.30
Cooling
(A35/W7)Capacity kW 20.00
EER (COP) 2.22
Power input kW 9.01
Cooling
(A35/W18)Capacity kW 20.00
EER (COP) 3.55Power input kW 5.64
Pressure difference (water circuit) kPa -
Cooling pump input (based on EN14511) kW -
Recommended plate heat exchanger ACH70-40 x 2 Parallel connection
The table shows performance data obtained when a plate heat exchanger is connected.
-
7/21/2019 Mitsubishi Electric Ecodan Data Book
22/322
O
td
it
A-18
Specifications1 Outdoor unit
40
45
50
55
60
65
-20 -15 -10 -5 0 5 10Ambient temperature [ C]
Maximum
outletwatertemperature[C
]
Maximum
outletwatertemperature[C
]
Maximum
outletwatertemperature[C
]
PUHZ-W50VHA(-BS)
PUHZ-HW112/140YHA2(-BS) PUHZ-HW140VHA2(-BS)
PUHZ-W85VHA2(-BS)
40
45
50
55
60
65
-20 -15 -10 -5 0 5 10
Ambient temperature [ ]
40
45
50
55
60
65
-25 -20 -15 -10 -5 0 5 10
Ambient temperature [ ]
1.3 Maximum outlet water temperature(1) Packaged-type units Power inverter
Zubadan
-
7/21/2019 Mitsubishi Electric Ecodan Data Book
23/322
Outdoorunit
A-19
Specifications1 Outdoor unit
(2) Split-type units
Power inverter
PUHZ-SW40/50VHA PUHZ-SW75VHA
PUHZ-SW100/120VHA
PUHZ-SW100/120YHA
40
45
50
55
60
65
-20 -15 -10 -5 0 5 10
-20 -15 -10 -5 0 5 10
Ambient temperature [ ]
Maximum
outletwatertemperature[C
]
Maximum
outletwatertemperature[C
]
40
45
50
55
60
65
-20 -15 -10 -5 0 5 10
-20 -15 -10 -5 0 5 10
Ambient temperature [ ]
Mr.SLIM+
PUHZ-FRP71VHA
Maximum
outletwatertemperature[C
]
40
45
50
55
60
65
-20 -15 -10 -5 0 5 10
Ambient temperature [ ]
Maximum
outletwatertemperature[C
]
40
45
50
55
60
65
Ambient temperature [ ]
Maximum
outletwatertemperature[C
]
40
45
50
55
60
65
Ambient temperature [
PUHZ-RP200/250YKA
Zubadan
PUHZ-SHW80/112VHA
PUHZ-SHW112/140YHA
PUHZ-SHW230YKA
Maximumou
tletwatertemperature[C
]
40
45
50
55
60
65
-25 -20 -15 -10 -5 0 5 10
Ambient temperature [ ]
-
7/21/2019 Mitsubishi Electric Ecodan Data Book
24/322
O
td
it
A-20
Specifications1 Outdoor unit
1.4 Available range (Water flow rate, return water temp.)(1) Packaged-type units Heating
5.0
6.0 7.0 8.0 9.0 10.0 11.0 12.0 13.0 14.0
7.0
9.0
11.0
13.0
15.0
17.0
19.0
Water flow rate [L/min]
10.0
14.0 19.0 24.0 29.0 34.0 39.0
12.0 14.0 16.0 18.0 20.0 22.0 24.0
Water flow rate [L/min]
Water flow rate [L/min]
Returnwatertemp[
]
5.0
7.0
9.0
11.0
13.0
15.0
17.0
19.0
Returnwatertemp[]
5.0
7.0
9.0
11.0
13.0
15.0
17.0
19.0
21.0
23.0
25.0
Returnwatertemp[]
PUHZ-W50VHA(-BS)
PUHZ-W85VHA2(-BS)
PUHZ-HW112/140YHA2(-BS) PUHZ-HW140VHA2(-BS)
Available range
Available range
Available range
-
7/21/2019 Mitsubishi Electric Ecodan Data Book
25/322
Outdoorunit
A-21
Specifications1 Outdoor unit
(2) Split-type units
5.0 7.0 9.0 11.0 13.0 15.0 17.0 19.0
5.0
7.0
9.0
11.0
13.0
15.0
17.0
19.0
5.0
7.0
9.0
11.0
13.0
15.0
17.0
19.0
Water flow rate [L/min]
8.0 10.0 12.0
12.0 16.0 20.0 24.0 28.0 32.0 36.0 40.0 44.0 48.0
14.0 16.0 18.0 20.0 24.022.0
Water flow rate [L/min]
Water flow rate [L/min]
Returnwatertem
p[]
Returnwatertemp[]
5.0
7.0
9.0
11.0
13.0
15.0
17.0
19.0
Returnwatertemp[]
PUHZ-SW40/50VHA(-BS)
PUHZ-SW75VHA(-BS) PUHZ-SHW80VHA
PUHZ-SW100/120VHA(-BS)PUHZ-SW100/120YHA(-BS)
PUHZ-SHW112VHAPUHZ-SHW112/140YHA
Available range
Available range
Available range
When a recommended plate heat exchanger is installed
-
7/21/2019 Mitsubishi Electric Ecodan Data Book
26/322
O
td
it
A-22
Specifications1 Outdoor unit
25.0 35.0 45.0 55.0 65.0 75.0 85.0
Water flow rate [L/min]
Water flow rate [L/min]
5.0
7.0
9.0
11.0
13.0
15.0
17.0
19.0
Returnwatertemp[]
PUHZ-RP200YKA PUHZ-SHW230YKA
PUHZ-RP250YKA
PUHZ-FRP71VHA
5.0
7.0
9.0
11.0
13.0
15.0
17.0
19.0
8.0 10.0 12.0 14.0 16.0 18.0 20.0 24.022.0
Returnwatertemp[]
Available range
Available range
-
7/21/2019 Mitsubishi Electric Ecodan Data Book
27/322
Outdoorunit
A-23
Outlines and dimensions2 Outdoor unit
2.1 Packaged-type unitsPUHZ-W50VHA(-BS)
Earthterminal
Handleformoving
TerminalConnec
tions
LeftPowersu
pplywiring
RightControllerwiring
Handleformoving
Servicepan
el
23
371
740
322
950
469
WaterIN
AirIntake
WaterOUT
Handleformoving
RearAirIntake
Handleform
oving
50
seeDetail
Powersupply
wiringhole
(2-27KnockOut)
Frontcover
40 11934
SideAir
Intake
Handleformoving
RearAirIntake
SideAirIntake
AirDischarge
2-12x36ovalholes
(FoundationBoltM10)
2-UShapednotchedholes
(FoundationBoltM10)
InstallationFeet
53
417
370 28
1
75
175
600
19
330 30
Drainhole
(5-33)
30
81219
220
145
145
145
Detail
ISO228/1-G1B
85269
24
FOUNDATION
Pleasesecuretheunitfirmly
with4foundation(M10)bolts.
(Boltsandwashersmustbe
purchasedlocally.)
Servicespace
Dimensionsofspaceneeded
forserviceaccessare
showninthebelow
diagram.
FREE
Over300mm
Ove
r10mm
Thediagrambelows
howsa
basicexample.
Explanationofparticulardetailsare
givenintheinstallationmanualsetc.
Over
500mm
Ove
r10mm
1FREE
SPACE
(Aroun
dtheun
it)
2SERVICE
SPACE
3FOUNDATION
BOLTS
Lessthan
Over
Over
Over300
500
500
Over10
30
Unit : mm
-
7/21/2019 Mitsubishi Electric Ecodan Data Book
28/322
O
td
it
A-24
Outlines and dimensions2 Outdoor unit
PUHZ-W85VHA2(-BS) Unit : mm
RearAirIntake
SideAirIntake
AirDischarge
2-12x3
6ovalholes
(FoundationBoltM10)
2-UShapednotchedholes
(FoundationBoltM10)
InstallationFeet
53
417
370 28
175
175
600
19
330 30
Drainhole
(5-33)
30
81219
220
145
145
145
Handleformoving
SideAirIntake
Handleformoving
RearAirIntake
WaterIN
AirIntake
WaterOUT
Handleformoving
57
Pow
ersupplywiringhole
(2-
27knockout)
SeeDetail
SidePanelR
Frontcover
34
40 119
Detail
ISO228/1-G1B
98269
24
Servicepanel
Handleformoving
Handleformoving
Termina
lConnections
Left...Powersupplywiring
Right...Controllerwiring
Earthterminal
322
943
23
473
950
673
FOUNDATION
Pleasesecuretheunitfirmly
with4foundation(M10)bolts.
(Boltsandwashersmustbe
purchasedlocally.)
Servicespace
Dimensionsofspaceneeded
forserviceaccessare
showninthebelow
diagram.
FREE
Over300mm
Ove
r10mm
Thediagrambelowshowsa
basicexample.
Explanationofparticu
lardetailsare
givenintheinstallatio
nmanualsetc.
Over
500mm
Over10mm
1FREE
SPACE(
Aroun
dtheun
it)
2SERVICE
SPACE
3FOUNDATION
BOLTS
Lessthan
Over
Over
Over300
500
500
Over10
30
-
7/21/2019 Mitsubishi Electric Ecodan Data Book
29/322
Outdoorunit
A-25
Outlines and dimensions2 Outdoor unit
PUHZ-HW112YHA2(-BS) PUHZ-HW140V/YHA2(-BS)
VHA
YHA
931
1079
A
WaterIN
WaterOUT
Handleformoving
RearAirIntake
Handleformoving
59
Over10mm
Over
500m
m
Over10mm
Over300mm
FREE
ISO228-1
G1B
Detail
24
466 74
Handleformoving
Handleformoving
Handleformoving
Servicepanel
Terminalconnections
LeftPowersupplywiring
RightControllerwiring
Earthterminal
A
23
371635
1350
322
1020
Fro
ntcover
AirIntake
Powersupply
wiringhole
(2-27KnockOut)
seeDetail
34
7440
InstallationFeet
2-UShapednotchedholes
(FoundationBoltM10)
2-1236ovalholes
(FoundationBoltM10)
RearAirIntake A
irDischarge
SideAirIn
take
2853
37019
417
210
600
210
330 30
Drainhole
(5-33)
81219
256
133
133
133
S
ideAirIntake
Handleformoving
FOUNDATION
Pleasesecuretheunitfirmly
with4foundation(M10)bolts.
(Boltsandwashersmustbe
purchasedlocally.)
Servicespace
Dimensionsofspaceneeded
forserviceaccessare
showninthebelow
diagram.
Thediagrambelow
showsa
basicex
ample.
Explana
tionofparticulardetailsare
givenin
theinstallationmanualsetc.
1FRE
E
SPACE
(Aroun
dtheun
it)
2SERVICE
SPA
CE
3FOUNDATION
BOLTS
Lessthan
Over
Over
Over300
500
500
Over10
30
Unit : mm
-
7/21/2019 Mitsubishi Electric Ecodan Data Book
30/322
O
td
it
A-26
Outlines and dimensions2 Outdoor unit
2.2 Split-type unitsPUHZ-SW40/50VHA(-BS)
100 mm or more as long asno obstacle is placed on therear and right-and-left sidesof the unit.
*1 In the place where short cycle tends to occur,cooling and heating capacity and power consumption might get lowered 10%. Air outlet
guide (optional PAC-SG58SG) will help them improve.
*2 If air discharges to the wall, the surface might det stained.
Please secure the unit firmlywith 4 foundation (M10) bolts.(Bolts, washers and nut mustbe purchased locally).
FOUNDATION BOLTS
Minimum installation space for outdoor unit
Free space around the outdoor unit(basic example)
Piping and wiring connection canbe made from the rear direction only.
PIPING-WIRING DIRECTION
Handle for moving
Handle for
moving
18
69
10
600
300
287.5
800
Terminal connectionsLeft Power supply wiringRight Indoor/Outdoor wiring
Service panel
Earth terminal
Service panelfor charge plug
Connection forliquid pipe FLARE 6.35(1/4F)
Connection forgas pipe FLARE 12.7(1/2F)Service port
183
440
23
901
55
35
43
6-33 drain hole2-12 drain hole
70
45
400
500
347.4
2260
43.6
15515274.3
0
60
118
0
284.3
Lessthan
18mm
100mm or more500mm or more
2 sides should be open inthe right,left and rear side.
*1*2 *1
350mm or more100mm or more
Basicallyopen
Air discharge
4-1021 oval hole
Side air intake
Rear air intake
32.540
330
300
365
150 500
Installation bolt pitch
FOUNDATION
Unit : mm
-
7/21/2019 Mitsubishi Electric Ecodan Data Book
31/322
Outdoorunit
A-27
Outlines and dimensions2 Outdoor unit
PUHZ-SW75VHA(-BS) Unit : mm
AirIntake
RearAirIntake H
andleformoving
Handleformoving
322
950
473
943
23
*1447
*1431
673
21
Handleformoving
Handleformoving
Servicepanel
Earthterminal
LeftPowersupplywiring
RightIndoor/Outdoo
rwiring
TerminalConnections
Rearpipingcover
Frontpip
ingcover
SideAirIntake
Handleformoving
40
54
2837019
417
53
57
41
600
175
175
330
RearAirIntake
AirDis
charge
SideAirIntake
InstallationFeet
2-U
Shapednotchedholes
(FoundationBoltM10)
2-123
6ovalholes
(FoundationBoltM10)
30
220
145
145
145
30
81219
71
71 Bottomp
ipingho
le
(Knockout)
Drainhole
(5-33)
PipingKnockoutHoleDetails 1
9
55
232792
92
40
75
7363Rightpipinghole
(Knockout)
Righttrunkinghole
(K
nockout)
Powersupplywiringhole
(2-27Knockout)
92
2755
73 2363
40
92
654
5
Frontpipinghole
(Knockout)
Fronttrunkinghole
(Knockout)
Powe
rsupplywiringhole
(2-2
7Knockout)
92
40
45 6
5
92
2755
237363
Rearpipinghole
(Knockout)
Reartrunkinghole
(Knockout)
Powersupplywiringhole
(2-27Knockout)
92
Example
ofNotes
RefrigerantGAS
pipeconnection(FLARE)15.88(5/8inch)
RefrigerantLIQUID
pipeconnection(FLARE)9.52(3/8inch)
*1...IndicationofSTO
P
VALVE
connectionlocation.
Over
Over
Lessthan
Pipingandwir
ingconnections
canbemadef
rom4
directions:
front,right,rea
randbelow.
4PIPING-WIRINGDIRECTIONS
3FOUNDATION
BOLTS
2SERVICESPACE
1FREESPAC
E(Aroundtheunit)
Thediagramb
elow
showsa
basicexample.
Explanationofparticulardetailsis
givenintheinstalla
tionmanualsetc.
Over10
500
500
Over100
Dimensionsofspaceneeded
forserviceaccessare
showninthebelow
diagram.
Servicespace
30
Pleasesecuretheunitfirmly
with4foundation(M10)bolts.
(Boltsandwashersmustbe
purchasedlocally.)
FOUNDATION
over100mm
over500mm
over10mm
FREE
over10mm
-
7/21/2019 Mitsubishi Electric Ecodan Data Book
32/322
O
td
it
A-28
Outlines and dimensions2 Outdoor unit
PUHZ-SW100/120VHA(-BS)
PUHZ-SW100/120YHA(-BS)
Handleformoving
SideAirIntake
Frontpipingcov
er
Rearpipingcov
er
Airintake
RearAirIntake
Handleformovi
ng
Handleformoving
Terminalconnection
LeftPowersupplywiring
RightIndoor/Outdoorwiring
Earthterminal
Servicepanel
Handleformoving
1 2
AirDischarge
RearAirIntake
SideAirIntake
RefrigerantGASpipeconnction(FLARE)15.88(5/8inch)
RefrigerantLIQUID
pipeconnection(FLARE)9.52(3/8inch)
*1
Indicatio
nofSTOPVALVEconnectionlocation.
Exam
pleofNotes
PipingK
nockoutHoleDetails
600
175
175
330
417
42
66
5356
45
(19) 28370
2-U
Shapednotchedholes
(FoundationBoltM10)
2-12x36Ovalholes
(FoundationBoltM10)
In
stallationFeet
30
45
40
65
92
2755
237363
Rearpipinghole
(Knockout)
Reartrunkinghole
(Knockout)
Powersupplywiringhole
(2-27Knockout)
92
19
55
92
75
40
7363
232792Rightpipinghole
(Knockout)
Righttrunkinghole
(Knock
out)
Powersupply
wiringhole
(2-27Knocko
ut)
92
92
654
5
40
2755
237363
Frontpipinghole
(Knockout)
Fronttrunkinghole
(Knockout)
Powersupplywiringhole
(2-27Knockout)
92
145
145
220
30
145
81219
71
71
Bottomp
ipinghole
(Knockout)
Drainhole
(5-33)
1350
23
950
A
*1447
*1431
371635
322
Handleformoving
VHA
YHA
1,079
A930
Over
Over Over
Over
Lessthan
Pipingandwiringconnections
canbemadefro
m4
directions:
front,right,rear
andbelow.
4PIPING-WIRING
DIRECTIONS
3FOUNDATIONBOLTS
2SERVICESPACE
1FREE
SP
ACE
(Aroundtheunit)
Pleasesecuretheunitfirmly
with4foundation(M10)bolts.
(Boltsandwashersmustbe
purchasedlocally.)
Dimensionsofspaceneeded
forserviceaccessare
showninthebelow
diagram.
Thediagramb
elow
showsa
basicexample
.
Explantionofp
articulardetailsis
givenintheinstallationmanualsetc.
30
FOUNDATION
10
500
500150
Servicespace
FREE
Over10mm
Over10mm
Over150mm
Ove
r1000mm
Unit : mm
-
7/21/2019 Mitsubishi Electric Ecodan Data Book
33/322
Outdoorunit
A-29
Outlines and dimensions2 Outdoor unit
PUHZ-RP200/250YKA
FOUNDATION
30
Servicespace
150500
500
10
Thediag
ramb
elow
showsa
basicexample.
Explanationofparticulardetailsare
givenintheinstallationmanualsetc.
Dimensionsofspaceneeded
forserviceaccessare
showninthebelowdiagram
.
Pleasesecuretheunitfirmly
with4foundation(M10)bolts.
(Boltsandwashersmustbe
purchasedlocally.)
1FREE
SPACE(Aroundtheunit)
2SERVICESPACE
3FOUNDATION
BOLTS
4PIPING-WIRINGDIRE
CTIONS
Pipingandwiringconn
ections
canbemadefrom4
directions:
FRONT,Right,Rearand
Below.
Lessthan
OverOver
Over
Over
Over10mm
Over10mm
FREEOver150mm
Over1000mm
PUHZ-RP200YKA
PUHZ-RP250YKA
Model
424
450
A
connection
9.5
2(3/8F)
12.7
(1/2F)
RefrigerantGASpip
econnection(attachedJOINT)25.4
(Brazinglocally)
RefrigerantLIQUID
pipeconnection(FLARE)
*1IndicationofSTOPVALVEconnectionlocation.
*2(FLARE)19.05(3
/4F)
1 2
2
ExampleofNotes
PipingKnock
outHoleDetails
Powersupplywiringhole
(27Knockout)
Frontpipinghole
(Knockout)
Fronttrunkinghole
(Knockout)
Powersupplywiring
hole
(40Knockout)
60
55
63 73
55 27
26
75
92
60 92
Powersupplywiringhole
(27Knockout)
Rightpipinghole
(Knockout)
Righttrun
kinghole
(Knockou
t)
Powersupplywiringhole
(40
Knockout)
75
50
2627
63 73 29
92
55
92
60 92
Powersupplywiringhole
(27Knockout)
Rearpipinghole
(Knockout)
Reartrunkinghole
(Knockout)
Powersupplywiringhole
(40Knockout)
75
60
55
63 73 26
55 27
60
92
92
Drainhole
(5-33)
Bottomp
ipinghole
(Knockout)
81
45154 136
110
160
1
60
160
86
1
050
Rea
rAirIntake
AirD
ischarge
SideAirIntake
InstallationFeet
2-U
Shapednotchedholes
(FoundationBoltM10)
2-1236Ovalholes
(FoundationBoltM10)
28370
60
30
225
225
330
600
417
19
70
42
40
53
56
0
Handlefor
moving
RearAirIntake
SideAirIntake
Handlefor
moving
632 369
26
1338
Handleformoving
Handleformoving
Ea
rthterminal
362
Brazing
Servicepanel
Terminalconnection
LeftPowersupplywiring
RightIndoor/Outdoorwiring
*1,*2:442
982986
*1A
342
Airintake
2
1
Frontpipingcover
Rearpiping
cover
Unit : mm
-
7/21/2019 Mitsubishi Electric Ecodan Data Book
34/322
O
td
it
A-30
Outlines and dimensions2 Outdoor unit
PUHZ-FRP71VHA
Dimensionsofspace
neededforserviceaccess
areshowninthebelow
diagram.
Pleasesecuretheunitfirmly
with4foundation(M10)bolts.
(Boltsandwashersmustbe
purchasedlocally.)
Pipingandwiringconn
ections
canbemadefrom4
directions:
Front,right,rearandb
elow.
4PIPING-WIRINGDIRECTIONS
3FOUNDATION
BOLTS
2SERVICE
SPACE
1FREES
PACE
(Aroun
dtheun
it)
Thediagram
below
showsabasic
example.
Explantionofparticulardetailsare
giveninthei
nstallationmanualsetc.
Rearpipinghole
(Knockout)
Reartrunkinghole
(Knockout)
73 23
55 27
92
65
92
Powersupplywiringhole
(2-27Knockout)
Fronttrunking
hole
(Knockout)
Frontpipinghole
(Knockout)
45
65
924
0
63 2373
55 27
92
Rightpipinghole
(Knockout)
Righttru
nkinghole
(Knocko
ut)
Powersu
pplywiringhole
(2-27Kn
ockout
19
55
232792
92
40
75
7363
92
PipingKnockoutHoleDetails
3 421
...Refrige
rantGASpipeconnection(FLARE)15.8
8(5/8F)
*Connecttoindoorunit.
...Refrige
rantLIQUID
pipeconnection(FLARE)9.5
2(3/8F
*Conne
cttoindoorunit.
...Refrige
rantGASpipeconnection(FLARE)15.8
8(5/8F)
*Conne
cttocylinderunitorhydrobox.
...Refrige
rantLIQUID
pipeconnection(FLARE)9.5
2(3/8F
*Conne
cttocylinderunitorhydrobox.
Exam
pleofNotes
Thistapmarkindicatesthecylinder/hydrounit
connectionsideforthefollowingparts.
Terminalbedfortheconnectingcables,S1/S2/S3.
Stopvalves,gasandliquidfortherefrigerantconnection.
BK7
9F295
H01
AirD
ischarge
SideAirIntake
RearAirIntake
2-1236ovalholes
(FoundationBoltM10)
2-U
Shapednotchedholes
(FoundfationBoltM10)
InstallationFeet
417
61
54
53
37019 28
41
42
42
42
175
175
600
330 30
43Cylinder/Hydroboxwiring
TerminalConnections
1 2Handleformoving
Servicepanel
TerminalConnections
Left
Powersupplywiring
Right
Indoor/Outdoorwiring
Earthterminal
Handle
formoving
950
322
943
473
23
673
429
375
696
Rearpipingcover
Frontp
ipingcover
Over500mm
Over100mm
FREE
Over10mm
Over10mm
Drainhole
5-33
145
145
145
220
30
81219
Handlefor
moving
RearAirIntake H
andle
formoving
AirIntake
SideAirIntake
Handle
formovin
g
Over
Over Over
Over
Lessthan
30
FOUNDATION
10
500
500100
Servicespace
Unit : mm
-
7/21/2019 Mitsubishi Electric Ecodan Data Book
35/322
Outdoorunit
A-31
Outlines and dimensions2 Outdoor unit
PUHZ-SHW80/112VHA
PUHZ-SHW112/140YHA
Unit : mm
Handleformoving
SideAirIntake
Frontpipingcover
Rearpipingcover
Airintake
RearAirIntake
Handleformoving
AirDischarge
RearAirIntake
SideAirIntake
RefrigerantGASpipeconnection(FLARE)15.88(5/8inch)
RefrigerantLIQUIDpipeconnection(FLARE)
9.52(3/8inch)
1Indication
ofSTOPVALVEconnectionlocation.
ExampleofNotes
PipingKn
ockoutHoleDetails
600
175
175
330
417
42
66
5356
45
(19) 28370
2-UShapednotchedholes
(FoundationBoltM10)
2-12x36Ovalholes
(FoundationBoltM10)
InstallationFeet
30
45
40
65
92
2755
237363
Rearpipinghole
(Knockout)
Reartrunkinghole
(Knockout)
Powersupplywiringhole
(2-27Knockout)
92
19
55
92
75
40
7363
232792Rightpipinghole
(Knockout)
Righttrun
kinghole
(Knockou
t)
Powersupplywiringhole
(2-27Knockout
)
92
92
654
5
40
2755
237363
Frontpipinghole
(Knockout)
Fronttrunkingh
ole
(Knockout)
Po
wersupplywiringhole
(2-27Knockout)
92
145
145
220
30
145
81219
71
71
Bottom
pipinghole
(Knockout)
Drainhole
(5-33)
23
SHWVHA
SHWYHA
1,079
A930
Over
Over Over
Over
Lessthan
Pipingandwirin
gconnections
canbemadefro
m4directions:
front,right,rear
andbelow.
4PIPING-WIRING
DIRECTIONS
3FOUNDATION
BOLTS
2SERVICESPACE
1FREE
SP
ACE
(Aroundtheunit)
Pleasesecuretheunitfirmly
with4foundation(M10)bolts.
(Boltsandwashersmustbe
purchasedlocally.)
Dimensionsofspaceneede
d
forserviceaccessare
showninthebelowdiagram
.
Thediagram
belowshowsa
basicexample.
Explanationofparticulardetailsis
giveninth
einstallationmanualsetc.
30
FOUNDATION
10
500
500150
Servicespace
Handleformoving
Handleformoving
Servicepanel
A
21
1443
1447
635 371
1350
322
950
Handleformoving
Handle
for
moving
Earthterminal
Terminalconnection
LeftPowersupplywiring
RightIndoor/Outdoorwiring
Over10mm
Over10mm
Over150mm
Over1000mm
FREE
-
7/21/2019 Mitsubishi Electric Ecodan Data Book
36/322
O
td
it
A-32
Outlines and dimensions2 Outdoor unit
PUHZ-SHW230YKA
FOUNDATION
30
Servicespace
150500
500
10
Th
ediagramb
elow
showsa
ba
sicexample.
Ex
planationofparticulardetailsare
givenintheinstallationmanualsetc.
Dimensionsofspaceneeded
forserviceaccessare
showninthebelowdiagram.
Pleasesecuretheunitfirmly
with4foundation(M10)bolts.
(Boltsandwashersmustbe
purchasedlocally.)
1
FREESPACE(Aroundtheunit)
2SERVICESPACE
3FOUNDATION
BOLTS
4PIPING
-WIRINGDIRECTIONS
Pipingandwiringc
onnections
canbemadefrom4
directions:
FRONT,Right,RearandBelow.
Lessthan
OverOver
Over
Over
Over
10mm
Ove
r10mm
FREEOver150mm
Over1000mm
RefrigerantG
ASpipeconnection(attachedJOINT)25.4
(Brazinglocally)
RefrigerantL
IQUID
pipeconnection(FLARE)9.5
2(3/8F)
*1IndicationofSTOPVALVEconnectionlocation.
*2(FLARE)
19.05(3/4F)
12ExampleofNotes
PipingKno
ckoutHoleDetails
Powersupplywiringhole
(27Knockout)
Frontpipinghole
(Knockout)
Fronttrunkingho
le
(Knockout)
Powersupplywirin
ghole
(40Knockout)
60
55
63 73
55 27
26
75
92
60
92
Powersupp
lyw
iring
ho
le
(27Knoc
kou
t)
Rightpipinghole
(Knockout)
Righttru
nkinghole
(Knocko
ut)
Powersupplywiringhole
(4
0Knockout)
75
50
2627
63 73 29
92
55
92
60 92
Powersupplywiringhole
(27Knockout)
Rearpipinghole
(Knockout)
Reartrunkinghole
(Knockout)
Powersupplywiringhole
(40Knockout)
75
60
55
63 73 26
55 27
60
92
92
Drainhole
(5-33)
Bottomp
ipinghole
(Knockout)
81
45154 136
110
160
160
160
86
1050
RearAirIntake
A
irDischarge
SideAirIntake
Insta
llationFeet
2-U
Shapednotchedholes
(FoundationBoltM10)
2-1236Ovalholes
(FoundationBoltM10)
28370
60
30
225
225
330
600
417
19
70
42
4053
560
Handlefor
moving
RearAirIntake
SideAirInta
ke
Handlefor
moving
632 369
26
1338
Handleformoving
Handleformoving
Earthterminal
362
Brazing
Servicepanel
Terminalconnection
LeftPowersupplywiring
RightIndoor/Outdoorwiring
*1,*2:442
982986
*1450
342
Airintak
e
2
1
Frontpiping
cover
Rearpipingcover
Unit : mm
-
7/21/2019 Mitsubishi Electric Ecodan Data Book
37/322
Outdoorunit
A-33
Wiring diagrams3 Outdoor unit
3.1 Packaged-type unitsPUHZ-W50VHA(-BS)
TB1
MC
MF1
21S4
63H
TH3
TH4
TH6
TH7
TH8
LEV-A, LEV-B
ACL
Terminal Block
Motor for Compressor
Fan Motor
Solenoid Valve(Four-Way Valve)
High Pressure Switch
63HS High Pressure Sensor
SV Solenoid Valve
Thermistor
Thermistor
Thermistor
Thermistor
Thermistor
TH33 Thermistor
TH32 Thermistor
Electronic Expansion Valve
Reactor
CY1, CY2 Capacitor
Power Circuit Board
Connection Terminal
P. B.
R/S
Noise Filter Circuit Board
Connection Terminal
Connection Terminal
N. F.
LI, LO
Connection TerminalNI, NOEI, E2, E3
Controller Circuit Board
Connector
Connector
Switch
Switch
Switch
Switch
SW1
SV1
CNDM
SW2
SW6
SW8
LED3 LED
C. B.
Power ModulePFC/IPM
Main Smocthing CapacitorCB1, CB2, CB3
52C Relay52C
SYMBOL NAME SYMBOL NAME
Connection Terminal
U/V/W
Switch
Switch
SW5
SW10
Relay
FuseF1, F2, F3, F4
X52, X54, X55
N. F.
LO
52C
NO
LI NI
CN5
(RED)
RED
CNAC
2
(RED
)
CN52C
(BLK)
2
2
1
3
E2
EI
1
21
2
1
BLK
BLK
E3
BLK
WHT
CNAC1
(WHT)3
MS3~
MF1
M
1
3
1
7
34 11 1 2 1
1 7
2
CNF1(WHT)
TRANS
CNDC(PNK)
TH7/6(RED)
TH3(WHT)
TH4(WHT)
TH7
t t t t
TH6 TH3 TH4
1 2TH32(BLK)
t
TH32
1 2TH33(YLW)
t
TH3363HS
63HS(WHT)
3 1
CNS(WHT)
63H(YLW)
31
63H
C. B.
P. B.
LED3
2 2
5
CN2(WHT)
F3
1 21 2
1313
CNAC(WHT)
CN4(WHT)
1 2
3 4
F4
F2
F1 21S4(GRN)
SV2(BLU)
X52
X55
13 SV1(GRY)
X54
21S4 SV
2
2
5
IPM
V
W
U
MS3~
UV
W
MC
S
R
CN2(WHT)
1
2
1
2
1
2
1
7
CN4
(WHT)
CN5(RED)
CN3(WHT)
RED
WHT
BLK
TH8
161 3 1 5CNVMNT
(WHT)CNMNT(WHT)
LEV-A(WHT)
LEV-A
1
5CN51
(WHT)
1
3CNDM
(WHT)
1
3CN3S
(WHT)
PFC
ACL
RED
RED
WHT
CB1 CB2 CB3
WHT
RED
WHT
M
61LEV-B(RED)
CN52C(RED)
LEV-B
t
L N
RED
BLU
BRN
ORN
YLW
GRN/YLW
TB1
CY1
CY2
S1 S2 S3
POWER SUPPLY~ / N 230V 50Hz
Interface unit /Flow temp. controller
*1 MODEL SELECT
*2 SW5 -1 to 3 : Function SwitchSW10 -1 : Function Switch
1 2 3 4 5 6
OFFON
SW6SW5-4 *2
OFFON
1 2 3 4
SW10-2 *2
OFFON
1 2
The black square ( ) indicates a switch position.
*1
*1
*1
SW6
SW1S
W8
SW2
SW7
SW5
SW10
-
7/21/2019 Mitsubishi Electric Ecodan Data Book
38/322
O
td
it
A-34
Wiring diagrams3 Outdoor unit
PUHZ-W85VHA2(-BS)
TB1
MC
MF1
21S4
63H
TH3
TH4
TH6
TH7
TH8
LEV-A, LEV-B
DCL
Terminal Block
Motor for Compressor
Fan Motor
Solenoid Valve (Four-Way Valve)
High Pressure Switch
63HS High Pressure Sensor
SV Solenoid Valve
Thermistor
Thermistor
Thermistor
Thermistor
Thermistor
TH32 Thermistor
TH33 Thermistor
Electronic Expansion Valve
Reactor
ACTM Active Filter Module
CY1, CY2 Capacitor
Power Circuit Board
Connection Terminal
P. B.
TABS/T
Noise Filter Circuit Board
Connection Terminal
Connection Terminal
N. F.
LI, LO
Connection TerminalNI, NO
EI, E2
Controller Circuit Board
Connector
Connector
Switch
Switch
Switch
Switch
SW1
SV1
CNDM
SW2
SW6
SW8
SwitchSW7
LED3 LED
C. B.
TABP1/P2
Power ModuleIPM
Diode bridgeDS2, DS3
52C Relay52C
SYMBOL NAME SYMBOL NAME
Connection Terminal
Connection Terminal
TABN1/N2 Connection Terminal
TABU/V/W
Switch
Switch
SW5
SW10
Relay
FuseF1, F2, F3, F4
X52, X54, X55
MS3~
MF1
M
1
3
1
7
34 11 1 2 1
1 7
2
CNF1(WHT)
TRANS
CNDC(PNK)
TH7/6
(RED)TH3
(WHT)TH4
(WHT)
TH7
t t t t
TH6 TH3 TH4
1 2
TH32
(BLK)
t
TH32
1 2
TH33
(YLW)
t
TH3363HS
63HS
(WHT)
3 1
CNS
(WHT)
63H(YLW)
3
1
63H
*1
*1
*1
C. B.
P. B.
N. F.
SW6
SW1S
W8
SW2
SW7
SW5
SW10
LED3
2
2 2
7
CN2(WHT)
F3
1 2 1 2
1313
1 3
2
71
1
2
1
2
1
2
7
6
CNAC(WHT)
CN4(WHT)
1 2
3 4
F4
F2
F121S4(GRN) SV2(BLU)
X52
X55
13 SV1(GRY)
X54
21S4 SV
2
2
L N
CNDC(PNK)
DS2
DS3
TABN
TABP
IPM
TABP2
TABV
TABW
TABN2
TABN1
TABS
TABP1
TABT
TABU
MS3~
UV
WMC
CN2
(WHT)
41
CNAF(WHT)
CN4(WHT)
CN5(RED)
CN3(WHT)
RED
RED
WHT
WHT
WHT
WHT
BLK
BLU
RED
BLU
BRN
ORN
YLW
GRN/YLW
BLK
TH8
t
161 3 1 5
CNVMNT(WHT)
CNMNT(WHT)
LEV-A(WHT)
LEV-A
1
5
CN51(WHT)
1
3
CNDM(WHT)
1
3
CN3S(WHT)
DCL
ACTM
L1
LO
52C
NO
LI NI
CN5
(RED)
L2
N2
Io
N1P
4
1 6
RED
BLK
BLK
BLK
RED
WHT
RED
BLU
CNAC2
(RED)
CNAC1
(WHT)
CN52C
(BLK)
WHT
2
2
1
3
E2
EI
1
21
2
3
1
TB1
CY1
CY2
S1 S2 S3
RED
POWER SUPPLY~ / N 230V 50Hz
Interface unit /Flow temp. controller
M
61LEV-B(RED)
CN52C(RED)
LEV-B
BLU
WHT
*1 MODEL SELECT
*2. SW5 -1 to 3 : Function SwitchSW10 -1 : Function Switch
1 2 3 4 5 6OFF
ON
SW6SW5-4
*2
OFF
ON
1 2 3 4
SW10-2
*2
OFF
ON
1 2
The black square ( ) indicates a switch position.
-
7/21/2019 Mitsubishi Electric Ecodan Data Book
39/322
Outdoorunit
A-35
Wiring diagrams3 Outdoor unit
PUHZ-HW112/140YHA2(-BS)
TB2
MC
MF1, MF2
21S4
63H
TH3
TH4
TH6
TH7
LEV-A, LEV-B, LEV-C
ACL1, ACL2, ACL3, ACL4
Terminal Block
Motor for Compressor
TB1 Terminal Block
Fan Motor
Solenoid Valve(Four-Way Valve)
High Pressure Switch
63L Low Pressure Switch
63HS High Pressure Sensor
Thermistor
Thermistor
Thermistor
Thermistor
TH8 Thermistor(internal)
TH33 Thermistor
TH32 Thermistor
Linear Expansion Valve
Reactor
CB1, CB2 Main Smoothing Capacitor
CK Capacitor
RS Rush Current Protect Resistor
Power Circuit Board
Connection Terminal
P. B.
TB-L1/L2/L3
Noise Filter Circuit Board
Connection Terminal
Connection Terminal
Connection Terminal
N. F.
LI1, LI2, LI3, NI
Converter Circuit Board
Connection Terminal
CONV. B.
L1-A1/IN
Connection TerminalL1-A2/OU
Connection TerminalL2-A2/OU
Connection Terminal
Connection TerminalN-IN
Connection TerminalCK-OU
L3-A2/OU
LO1, LO2, LO3, NO
GD1, GD3
Controller Circuit Board
Connector
Connector
Switch
Switch
Switch
Switch
SW1
SV1/CH
Connector
SS
ConnectorCN51
CNDM
SW2
SW6
SW8
SwitchSW7
LED3 LED
C. B.
TB-P2
SYMBOL NAME SYMBOL NAME
Connection Terminal
Connection Terminal
TB-C1 Connect ion TerminalTB-N1 Connection Terminal
X52A 52C Relay
TB-U/V/W
Switch
SW5
RelayFuseF1, F2, F3, F4
X51, X52, X54
MS3~
MF1 1
3
1
7 34 11 1 2
1 7
CNF1(WHT)
TRANS
MS3~
MF2 17
CNF2(WHT)
CNDC(PNK)
TH7/6(RED)
TH3(WHT)
TH4(WHT)
TH7
t t t t
TH6TH3 TH4
tTH8
1 2TH32(BLK)
t
TH32
1 3TH33(YLW)
t
63HS
63HS(WHT)
3 1
CNS(WHT)
63H(YLW)
31
63H
31
63L
C. B.
LED3
2
2
7
CN2(WHT)
F3
1 2
1 31 3
CNAC(WHT)
CN4(WHT)
1 2
3 4
F4
F2
F1 21S4(GRN)
X52
X54
1 3SV1(GRY)
X51
21S4
1
5CN51
(WHT)
1
3CNDM
(WHT)
71
21
+
--
--
+
+ +
+
+
ACL1
ACL2
ACL3
ACL4
CN7(WHT)
CN2(WHT)
TB-P2
CB1 CB2 CK
TB-C1
L3-OU
L2-OU
L1-OU
L3-A2
L2-A2
L1-A2
L1-A1
L1-IN
N-IN
CK-OU
TB-N1
TB-W BLK
WHT
RED
BLK
WHT
RED
BLK
BLU
WHT
RED
RED
RED
RED
RED
BLK
BLU
GRN/YLW
WHT
RED
TB-V
TB-U
TB-L3
TB-L2
TB-L1
W
V
U
MC
CN4(WHT)
CNAC1(WHT)
CN7
(WHT)
WHT
WHT
CN5(RED)
CNCT(RED)
CNL(BLU)
CNDC(PNK)
RS
CONV. B.
LO1
LO2
LO3
NO
LI1
LI2
LI3
NI
TB1
TB2
POWERSUPPLY3N~400V 50Hz
3 7
RED
WHT
BLK
BLK
BLK
BRN
WHT
RED
X52A
RED
3
1
3121
MS3~
GD1
++
--
1331
31
L1
L2
L3
N
S1
S2
S3
YLW
ORN
BRN
31
2
21
2
2
2
BLK
BLK
BLK
BLU
Interfaceunit /Flow temp.controller
12
TH33
63L(RED)
SS(WHT)
CNAC2(RED)
GD3
3
1
P. B.
N. F.
SW9
SW2
M M
51LEV-A(WHT)
LEV-B(RED)
LEV-BLEV-A
5TH34(RED)
t
TH34
12
5
M
LEV-C
5
51LEV-C(BLU)
1 3 1 5CNVMNT(WHT)
CNMNT(WHT)
*1
SW5
SW8
SW7
SW6
SW1
*1 *3
TH34 Thermistor
SwitchSW9
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
OFFON
112Y
MODEL SW6
*1 MODEL SELECT
*2. SW5 -1 to 5 : Function Switch
SW5-6 *2
OFFON
OFFON
140Y OFFON
1 2 3 4 5 6
1 2 3 4 5 6
1 2 3 4 5 6OFFON
SW7-1, 7-2 Ambient temp.
3 C (factory shipped)
*3 Ambient temp. of ZUBADAN Flash Injection becomes effective.
SW7-3 to 6 : Function Switch
1 2 3 4 5 6OFFON
0 C
1 2 3 4 5 6OFFON
-3 C
1 2 3 4 5 6OFFON
-6 C
Ambient temp.SW7-1, 7-2
The black square ( ) indicates a switch position.
The black square ( ) indicates a switch position.
L1
L2
L3
N
S1
S2
S3
-
7/21/2019 Mitsubishi Electric Ecodan Data Book
40/322
O
td
it
A-36
Wiring diagrams3 Outdoor unit
PUHZ-HW140VHA2(-BS)
SW9
SW2
M M
51 1LEV-A(WHT)
LEV-B(RED)
LEV-BLEV-A
5TH34(RED)
t
TH34
12
5
M
LEV-C
5
51LEV-C(BLU)
1 3 1 5CNVMNT
(WHT)CNMNT(WHT)
*1
SW5
SW8
SW7
SW6
SW1
*1 *3
TH34
SwitchSW9
MS3~
MF1 1
3
1
7 34 11 1 2 1
1 7
2CNF1(WHT)
TRANS
MS3~
MF2 17
CNF2(WHT)
CNDC(PNK)
TH7/6(RED)
TH3(WHT)
TH4(WHT)
TH7
t t t t
TH6TH3 TH4
1 2TH32(BLK)
t
TH32
1 3TH33(YLW)
t
TH3363HS
63HS(WHT)
3 1
CNS(WHT)
63H(YLW)
CN52C(RED)
31
31
63H
63L(RED)
31
63L
C. B.
IGBT
LED32 2
3
7
CN2(WHT)
F3
1 2
1 31 3
CNAC(WHT)
CN4(WHT)
1 2
3 4
F4
F2
F1 21S4(GRN)
X52
X54
1 3 SS(WHT)
SV1(GRY)
X51
21S4
1
5CN51
(WHT)
1
3CNDM
(WHT)
DCL2
N2
P2
MS3~
U
U
V
V
W
W
CN2(WHT)
CN4(WHT)
1 71 2
2
CNDC(PNK)
BLK
WHT
CY1
CY2
LINIEI
E4
E2
E3
POWER SUPPLY~/N 230V 50Hz
Interface unit /
Flow temp. controller
TB1L N S1 S2 S3
MC
3
1
3
1
2
RED
CNAC1
(WHT)
CNAC2
(RED)
1 3
13
CN52C(RED)
52C
52C
BLU
YLW
GRN/YLW
ORN
BRN
RED
WHT
WHT
RED
RED
BLK BLK
BLK
BLK
DCL1
DCL
CB
t
TH8
P. B.
TB1
MC
MF1, MF2
21S4
63H
TH3
TH4
TH7
LEV-A, LEV-B, LEV-C
DCL
Terminal Block
Motor for Compressor
Fan Motor
Solenoid Valve(Four-Way Valve)
High Pressure Switch
63L Low Pressure Switch63HS High Pressure Sensor
Thermistor
Thermistor
TH6 Thermistor
Thermistor
TH33 Thermistor
TH32 Thermistor
Linear Expansion Valve
Reactor
CB Main Smoothing Capacitor
CY1, CY2 Capac itor
Power Module
Controller Circuit Board
Connector
Switch
Switch
Switch
SW1
Connector
Connector
SS
ConnectorCN51
CNDM
SW2
SW6
SwitchSW8
SwitchSW7
SV1
LED3 LED
C. B.
NI
SYMBOL NAME SYMBOL NAME
Connection Terminal
Connection Terminal
Connection Terminal
DCL1, DCL2
IGBT
EI, E2, E3, E4
Power Circuit Board
Connection Terminal
P. B.
LI Connection Terminal
U, V, W
Switch
SW5
Relay
FuseF1, F2, F3, F4
X51, X52, X54
TH8 Thermistor(internal)
Thermistor
1 2 3 4 5 6 7 8OFFON
140V
MODEL SW6
*1 MODEL SELECT
*2. SW5 -1 to 5 : Function Switch
SW5-6*2
OFFON
1 2 3 4 5 6
The black square ( ) indicates a switch position.
1 2 3 4 5 6OFFON
SW7-1, 7-2 Ambient temp.
3 C (factory shipped)
*3 Ambient temp. of ZUBADAN Flash Injection becomes effective.
SW7-3 to 6 : Function Switch
1 2 3 4 5 6OFFON
0 C
1 2 3 4 5 6OFFON
-3 C
1 2 3 4 5 6OFFON
-6 C
Ambient temp.SW7-1, 7-2
The black square ( ) indicates a switch position.
-
7/21/2019 Mitsubishi Electric Ecodan Data Book
41/322
Outdoorunit
A-37
Wiring diagrams3 Outdoor unit
3.2 Split-type unitsPUHZ-SW40/50VHA(-BS)
SYMBOL NAME SYMBOL NAME SYMBOL NAME
TB1
MC
MF1
21S4
63H
63HSTH3
TH4
TH6
TH7
TH8
TH34
LEV-A, LEV-B
ACL
CY1, CY2
Terminal Block
Motor for Compressor
Fan Motor
Solenoid Valve (Four-Way Valve)
High Pressure Switch
High Pressure SensorThermistor
Thermistor
Thermistor
Thermistor
Thermistor
Thermistor
Linear Expansion Valve
Reactor
Capacitor
P. B.
N. F.
C. B.
Power Circuit Board
Connection Terminal
Connection Terminal
Power Module
Converter
Main Smoothing CapacitorNoise Filter Circuit Board
Connection Terminal
Connection Terminal
Connection Terminal
52C Relay
Controller Circuit Board
Switch
Switch
R, S
U, V, W
IPM
PFC
CB1, CB2, CB3
LI, LO
NI, NO
EI, E2, E3
52C
SW1
SW4
SW5
SW6
SW7
SW8
SW9
SWP
CN31
CNDM
CN51
SV1/CH
SS
CNM
LED1, LED2
F1, F2, F3, F4X51, X52, X54
Switch
Switch
Switch
Switch
Switch
Switch
Connector
Connector
Connector
Connector
Connector
Connector
LED
Fuse
Relay
C. B.
P. B.
TH8
TH6TH7 TH4TH3
U
CB3
N. F.
21S4
L N S1 S2 S3
INDOORUNIT
POWER SUPPLY~/N 230V 50Hz
TB1
VW
5
2
2
2
2
RED
WHT
BLK
t t t t t
t
M C
C
N5
(R
ED)C
NAC2
(RED)
CNAC1
(WHT)
LO N O
LI N I EI
CN52C
(BLK)
3
1
1
3
2
1
1
2
52C
CN2(WHT)
CN3(WHT)
CN5(RED)
CN4(WHT)
1
7
12
12
21
LEV-A
CNS(WHT)
CNAC(WHT)
CNDC(PNK)
F2
F1
F3
F4 21S4(GRN)
CN2(WHT)
CN4(WHT)
CN3S
(WHT)
TH7/6(RED)
TH3(WHT)
TH4(WHT)
TRANS
CNVMNT(WHT)
CNMNT(WHT)
CNM(WHT)L
ED1
LED2
X52
SV1/CH
(GRY)
X54
63H(YLW) CN52C
(RED)
2
5
2
1 4 1 2 2 1
1 3
31 1 5
1 14
1
31 2 1 2
1 7
3
1
13
1 2
3 4
31 31
LEV-A(WHT)
51
MS3~
CB2CB1
R
S
U
V
W
PFCIPM
AC L
E3
E2
RED
BLU
RE D
W H T
RE D
W HT
YLW
ORN
BLK
BLK
BLK
BRN
RE D
W HT
RE D
W H T
CY1
CY2GRN/YLW
SS(WHT)
X51
31
MS3~
MF1 CNF1(WHT)
17
63H
31
TH34
2 1TH34(RED)
63HS(WHT)
63HS
LEV-B(RED)
M
LEV-B
51
M
CNDM
(WHT)
CN51
(WHT)
1
31
5
+ + +
SW7
SW6
SW1 SW
9
CN31
SW5
S
W8
SW4SWP
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
OFF
ON40V
MODEL SW6 SW5-6 *2
OFF
ON
OFF
ON50V OFF
ON
1 2 3 4 5 6
1 2 3 4 5 6
*1 MODEL SELECTThe black square ( ) indicates a switch position.
*2 SW5 -1 to 5 : Function Switch
*1 *1
-
7/21/2019 Mitsubishi Electric Ecodan Data Book
42/322
O
td
it
A-38
Wiring diagrams3 Outdoor unit
PUHZ-SW75VHA(-BS)
1 2 3 4 5 6 7 8OFFON
75V
MODEL SW6
*1 MODEL SELECTThe black square ( ) indicates a switch position.
SW5-6 *2
OFFON
1 2 3 4 5 6
*2 SW5 -1 to 5 : Function Switch
SYMBOL