Download - Microtek ScanMaker 3880 (Service Manual)
-
1
Table of Contents for ScanMaker 3880
Table of Contents Page No.
Table of Contents
1
SCANNER FEATURE OF ScanMaker 3880 2
ELECTRICAL PARTS LIST OF ScanMaker 3880
5
MECHANICAL PARTS LIST OF ScanMaker 3880
6
MECHANICAL DRAWING OF ScanMaker 3880
7
OPTICAL DRAWING IN REFLECTIVE MODE
12
HOW YOU REMOVE UPPER HOUSING ASSEMBLY FROM SM 3880
13
REPAIR FLOW OF ScanMaker 3880
14
FEATURE LIST OF ScanMaker 3880
16
THE LOGO OF SAFETY MARK AND EMI FROM POWER LABEL OF
ScanMaker 3880
17
SYSTEM WIRING DIAGRAM OF ScanMaker 3880
18
SYSTEM BLOCK DIAGRAM OF ScanMaker 3880
19
WHERE YOU FIND MODEL CODE OF SM 3880 IN S/W DRIVER :
ScanWizard 5 V6.113
20
ScanMaker 3880 designs
with USB2.0 interface and
its optical resolution is
2400dpi (V) x 1200dpi (H)..
Its driver : ScanWizard 5
V6.113 or its later version
can support SM 3880 to do
photo scanning under PC
Windows system only, and
SM 3880 can also equip with
LightLid-35 for 35mm film
scanning.
-
2
SCANNER FEATURE OF ScanMaker 3880
SCANNER TYPE : flatbed scanner offer 3 buttons function ( Scan / Copy / E-mail ).
One pass , 48Bit ( R,G,B ) color scanner with USB2.0 interface.
The following S/W driver can support ScanMaker 3880 to do photo scanning under PC Wins system.
ScanWizard 5 V6.113 or its later version ( PC version ) : PC WinXP / 2K / Me / 98 system.
OPTICAL RESOLUTION : 1200dpi (H) * 2400dpi (V)
SCAN AREA : 8.5 (W) * 11.7 (L) in Reflective mode,
CCD TYPE : 2905D ( Toshiba CCD ) , 5400 PIXELS ( 5100 EFFECTIVE PIXELS ).
TCD-2905D is a stack CCD with 6 rows of line sensors ( R1,R2, B1,B2, G1 & G2 ),
each of line sensor has 5400 pixels totally, but R1 and R2 has 0.5 pixel shift in alignment
each other ( G1and G2, B1and B2 have the same design also. ). This reason can make
scanner resolution was enhanced from 600dpi ( 600dpi * 8.5 ( W ) = 5100 effective pixels )
to 1200dpi ( R1 + R2 = 10200 effective pixels = 1200dpi * 8.5 ( W ) ).
A/D CONVERTER : Chip Scan113 (16BIT/Pixel ) on Main Board ( MARCH-0503 ).
SENSOR : HOME SENSOR *1 ( IN THE BUTTON BOARD, MARCH-BUT ).
STEPPING MOTOR : 12Vdc/0.5A ( NEOCENE 2T3542142 ), MOTOR STEP=3.75 DEGREE/STEP
MICRO STEPPING RATE = FULL, HALF
FULL STEP = 1200 dpi ( V )
HALF STEP = 2400 dpi ( V ) ( ScanMaker 3880 run at 2400dpi )
STEPPING MOTOR DRIVER : IC CHIP ( 6219 ) ON MAIN BOARD ( MARCH-0503).
LAMP TYPE : COLD CATHODE LAMP *1 IN CARRIAGE ASSEMBLY OF ScanMaker 3880
AC-INVERTER : DC INPUT VOLTAGE = 12V
LAMP START-UP AC VOLTAGE = 550VP-P ( MINIMUM )
LAMP AC CURRENT = 10mA (APPROXIMATELY)
VIDEO MEMORY BUFFER : 1M WORD ON MAIN BOARD ( MARCH-0503 ).
DATA PROCESSING CHIP : SCAN CHIP : SQ113 ON MAIN BOARD ( MARCH-0503 ).
SCANNER CONTROLLER : SCAN CHIP : SQ113 ( 8 BIT PROCESSOR ) ON MAIN BOARD.
USB INTERFACE : SCAN CHIP : SQ113 ( USB CONTROLLER ), USB 2.0 INTERFACE.
DATA TRANSMISSION SPEED CAN BE UP TO 4M BYTE/SECOND
SCANNER POWER ADAPTER, O/P : 12Vdc/1.25A ( VENDOR : DVE or HARD )
R1 Line sensor has 5400 Pixels totally.
G1 Line sensor has 5400 Pixels totally.
B1 Line sensor has 5400 Pixels totally.
B2 Line sensor has 5400 Pixels totally.
-
3
Rear View OF ScanMaker 3880
Accessory of SM 3880 : LightLid-35 ( P/N :1108-03-520041 )
If your SM 3880 equips with LightLid 35 for film scanning, then we suggest you to do Lightlid 35
calibrator before you start ScanWizard to scan slide / negative film with Lightlid 35 for better quality.
USB 2.0 interface
connector *1
Power jack of scanner
( 12Vdc / 1.25A )
Power Label
( P/N : 219-21-820000 )
15 pin connector
for LightLid 35
The Label of scanner S/N. Attention Tag for power use
LightLid 35
Calibrator is an
AP and support
to do lamp
calibration for
your LightLid 35.
Left illustration is
a windows
message after
you start
LightLid 35
calibrator. You
can click
calibrate to
do lamp
calibration after
lamp in Lightlid
35 is warmed up
for 3 minutes.
-
4
Button Function OF ScanMaker 3880
Status LED Indicator : When scanner is powered up and link with PC via USB interface well, and
then LED indicator will light up in Green steadily while scanner is ready.
Scan Button : Scan to saved as file, or sent it to another application for further image processing.
Copy Button : Scan an image and send it to your printer for print-out directly.
E-mail Button : Scan an image and deliver it to your e-mail editor ( Outlook Express / Lotus Notes
/ Hotmail / Microsoft Outlook ) directly.
Above Button Function can be set or defined in Microtek Scanner Configuration ( MSC ) utility.
Scan
Button
Copy
Button
E-mail
Button
Status LED
Indicator
After you complete to install scanner driver : ScanWizard 5
into PC Windows system, and then you can find the icon of
Microtek Scanner Configuration , ScanWizard 5 , and
My Image will list you on the Desktop of Windows system.
Click the icon of ScanWizard 5 from the Desktop of Windows
system, and then you can get into the stand alone version of
ScanWizard 5 to do image scanning with Microtek scanner.
All of scanned images in ScanWizard 5 will be saved into My
images, its default path in PC Windows system located at "
C:\Program Files \ Microtek \ ScanWizard 5 \ My Images ".
This icon is Micortek Scanner Finder, is resident in PC
Windows system, it means PC Windows system can
not find the scanner is linking with PC well via interface.
This icon is Micortek Scanner Finder, is resident in PC
Windows system, it means PC Windows system has
found the scanner is linking with PC well via interface.
-
5
ELECTRICAL PARTS LIST OF ScanMaker 3880
1. MAIN BOARD : MARCH-0503 ( P/N : 1108-01-820000 )
2. CCD BOARD : MARCH-2905BFG ( IN CARRIAGE ASSEMBLY )
3. AC-INVERTER BOARD : HDDA4W101 ( P/N : 545-00-520005, locate in carriage assembly )
4. BUTTON BOARD : MARCH-BUT ( P/N : 1108-01-820002 )
5. POWER ADAPTER ( O/P : 12Vdc/1.25A ) : THE VENDOR IS DVE./ HARD.
EU type : HDAD15W101-124
( EU, 220VAC, P/N : 545-00-580001 )
EU type : DSA-0151A-12 UP
( EU / AP, 220VAC, P/N : 545-00-520016 )
UK type : HDAD15W101-126
( UK, 240VAC, P/N : 545-00-580003 )
Australia type : DSA-0151A-12 AS
( AUS, 220VAC, P/N : 545-00-520018 )
The function of AC-Inverter Board is to convert
the DC input ( 12Vdc ) to AC output ( 550VP-P ),
and then light up the lamp ( for photo scanning )
in the carriage assembly of scanner.
The vendor is HARD.
The function of CCD board is to
convert the optical signal to analogue
signal, and each of line sensor in the
CCD has 5,400 pixels totally.
The home sensor is positioned
in the button board.
LED is In Button Board.
-
6
MECHANICAL PARTS LIST OF ScanMaker 3880
A. DRESS UNIT ( P/N :I41-013141 )
a. BOOK COVER ASSEMBLY ( P/N : 215-01-820002 )
b. UPPER HOUSING ASSEMBLY ( P/N : I41-013142 )
b1. BUTTON BOARD, MARCH-BUT ( P/N : 1108-01-820002 )
c. BASE ASSEMBLY ( P/N : I41-013143 )
c1. MAIN BOARD : MARCH-0503 ( P/N : 1108-01-820000 )
c2. BOTTOM HOUSING ( P/N :215-01-820000 )
c3. CARRIAGE ASSEMBLY ( P/N :I41-013144 )
aa. CCD ASSEMBLY : ( P/N : I41-013145 )
bb. AC-INTERTER BOARD IN CARRIAGE ASSEMBLY ( P/N : 545-00-520005 )
cc. COLD CATHODE LAMP x 1pcs ( P/N : 570-19-520000 )
c4. MOTOR ASSEMBLY ( P/N : 215-17-820000 )
c5. IDLE PULLEY ASSEMBLY ( P/N : I41-009984 )
c6. SLIDING ROD ( P/N : 215-31-520000 )
c7. TIMING BELT, 388mm ( P/N : 404-88-000388 )
c8. CCD Flexible Flat Cable 19 pin, 404mm ( P/N :121-80-820000 )
c9. Button Flexible Flat Cable 9 pin, 434mm ( P/N : 121-80-820001 )
B. CARTON FOR SM 3880 ( AP / EU, P/N : 219-31-820000 ),
C. BOTTOM CUSHION ( P/N : 219-44-520012 )
D. TOP CUSHION ( P/N : 219-44-520013 )
E. POWER ADAPTER ( 12Vdc/1.25A ),
HDAD15W101-124 ( EU / AP, 220VAC, P/N : 545-00-580001 ).
DSA-0151A-12 UP ( EU / AP, 220VAC, P/N : 545-00-520016 ).
HDAD15W101-126 ( UK, 240VAC, P/N : 545-00-580003 ).
DSA-0151A-12 AS ( AUS, 220VAC, P/N : 545-00-520018 ).
F. USB2.0 GRAY Cable, 1.5m/4Pin with Core ( P/N : 121-44-150504 )
G. S/W BUNDLE ( P/N : I41-013151, AP VERSION ).
S/W BUNDLE ( P/N : I41-013150, EU VERSION ).
H. LIGHTLID 35 : 1108-03-520041
-
7
Mechanical Drawing of SM 3880
A. Dress Unit :I41-013141
B. Book Cover Assembly : 215-01-820002
C. Upper Housing Assembly : I41-013142
Book Cover Assembly :
215-01-820002
Upper Housing Assembly :
I41-013142
Base Assembly :
I41-013143
This center mark is for scanner CCD
center alignment during calibration.
The white area in this white stripe is
doing white calibration for the scanner.
This glass is glued and taped on the
upper housing.
-
8
D. Base Assembly : I41-013143
E. Idle Pulley Assembly ( P/N : I41-009984, not include Spring )
F. Motor Assembly : 215-17-820000 ( Step Motor : 12Vdc / 0.5A, NEOCENE 2T3542142 )
Carriage Assembly :
I41-013144
Bottom Housing :
215-01-820000
9 Pin Button
Flexible Cable :
121-80-820001
Button Board :
1108-01-820002
Sensor Bar
Timing Belt :
404-88-000388
Sliding Rod :
215-31-520000
Motor Assembly :
215-17-820000
Cold Cathode Lamp :
570-19-520000
Idle Pulley
Assembly :
I41-009984
Spring :
215-30-520000
Idle Pulley :
215-00-540018
Pulley Bracket :
215-20-520000
Base Lock is in the
bottom housing
Main Board :
1108-01-820000
19 Pin CCD Flat
Cable :
121-80-820000
E-ring, 4mm, Ni :
142-80-504000
-
9
G. Carriage Assembly-1 :I41-013144
Carriage Assembly-2 :I41-013144
Cold Cathode Lamp : 570-19-520000
Timing Belt, 388MXL : 404-88-000388
LOCK Mechanism of ScanMaker 3880
Cold Cathode Lamp : 570-19-520000
CCD Assembly
I41-013145
Lens Cover :
215-00-520002
Carriage Roller :
215-00-520003
AC-Inverter Board :
545-00-520005
Timing Belt Clamp
Sensor Bar
Carriage is in lock position.
Carriage is in unlock position.
-
10
Core for 9 pin flat cable : 141-10-520000
Core for19 pin flat cable : 141-10-520001
CCD Flexible Cable 19 pin, 435mm : 121-80-820001
Insulation Film for main board : 215-00-520008
I. USB2.0 Gray Cable : 121-44-150504
Button Flexible Flat Cable 9 Pin, 404mm :
121-80-820000
Core, M5W ZP33, 5*6.5*12 :
141-10-520000
Core, M5W ZP18, 9*6.5*12 :
141-10-520001
This insulation film is positioned
underneath main board.
-
11
J. SoftWare Bundle : I41-013150 ( EU version )
K. Power Adapter : 12Vdc / 1.25A ( P/N : 545-00-520015, US version )
L. Carton : 219-31-820000 ( AP / EU Version )
Bottom Cushion :
219-44-520013
Top Cushion :
219-44-520012
Support Frame :
215-00-222000
Plastic Handle :
580-01-222000
Power Adapter
( 12Vdc / 1.25A )
Carton for SM 3880 :
219-31-820000
S/W BUNDLE ( P/N : I41-013151, AP VERSION ).
S/W BUNDLE ( P/N : I41-013150, EU VERSION ).
HDAD15W101-124 ( EU / AP, 220VAC, P/N : 545-00-580001).
DSA-0151A-12 UP ( EU / AP, 220VAC, P/N : 545-00-520016 ).
HDAD15W101-126 ( UK, 240VAC, P/N : 545-00-580003 ).
DSA-0151A-12 AS ( AUS, 220VAC, P/N : 545-00-520018 ).
-
12
OPAQUE DOCUMENT
GLASS
UPPER LAMP
MIRROR
LENS MIRROR
CCD BOARD
OPTICAL PATH :
LAMP IN CARRIAGE UNIT : cold cathode lamp x 1pcs ( P/N : 570-19-520000 )
AC-INVERTER IN CARRIAGE UNIT OF SM 3880 : ( P/N : 545-00-520005 )
CCD TYPE : Toshiba CCD ( TCD-2905 ) is a stack CCD with 6 rows of line sensors
( R1,R2, B1,B2, and G1, G2 ), each of line sensor has 5,400 pixels totally, but
the effective pixels of each CCD line sensor for SM 3880 is 5,100 pixels only.
Hence, R1 + R2 = 10,200 pixels. The scan area of SM 3880 is 8.5 ( W ) * 11.7
( L ). This reason can make scanner resolution was enhanced from 600dpi
( 600dpi * 8.5 ( W ) = 5100 effective pixels ) to 1200dpi ( R1 + R2 = 10200
effective pixels = 1200dpi * 8.5 ( W ) ).
OPTICAL DRAWING : REFLECTIVE MODE FOR ScanMaker 3880
All of optical components ( mirrors,
lens, CCD, lamp, AC-inverter ) are in
Carriage Assembly of SM 3880.
-
13
How You Remove Upper Housing Assembly From SM 3880
Tool You need : This screwdriver is to remove two of screws from rear end of scanner.
Step 1 : Remove Book Cover Assembly from SM 3880 at first, and then remove two of
screws from rear end of scanner by using one cross-head screwdriver.
Step 2 : Separate the upper housing assembly from rear end of scanner by both hands,
and show you as below illustration.
Step 3 : Separate the upper housing assembly from scanner as below illustration.
There are two of screws ( P/N :
142-33-504012 ) are to fix upper housing
assembly into scanner here.
The P/N of screw is
142-33-504012.
This is upper housing assembly of SM3880. This is base assembly of SM3880.
-
14
REPAIR FLOW OF SCANMAKER 3880
1. Power Adapter NG
2. Main Board NG
3. Button Board NG
4. 9 Pin button cable NG
1. Reflective Lamp NG
2. AC-Inverter board NG
3. CCD Board NG
4. 19 Pin CCD flat cable NG
1. Step Motor NG
2. Main Board NG
3. Base Lock NG
4. Power Adapter NG
1. Button Board NG
2. 9 Pin button cable NG
3. Base Lock NG
4. Timing Belt NG
1. Main Board NG
2. Wrong scanner driver
3. USB Cable NG
4. Carriage Assembly NG
5. 19 Pin CCD flat cable NG.
6. Power Adapter NG.
Scanner power up
( LED light off )
Fail
Reflective Lamp light up
Fail
Motor run
Carriage unit travel to go
home sensor position
Fail
Fail
Fail
Scanner link with computer
host via USB2.0 interface
( LED go blinking )
-
15
1. Main Board NG
2. Carriage Assembly NG
3. 9 pin button cable NG
4. 19 Pin CCD flat cable NG.
5. Driver installation error.
6. USB cable NG
1. Button Board NG.
2. 9 pin button cable NG.
3. Main Board NG.
4. Scanner S/W Driver NG
1. Carriage Assembly NG
2. Reflective Lamp NG
3. 19 Pin CCD flat cable NG.
4. Main Board NG
5. Power Adapter NG
6. Calibration Ruler
( White Calibration
Stripe ) NG
Scanner is ready ( Scanner Finder find scanner
ScanMaker 3880 under PC Windows system )
( LED light up in Green steadily )
Color image NG on
photo scanning
OK
Fail
Fail
Fail
Button Function NG
This is an icon of Scanner Finder , it means scanner has linked
with PC Windows system successfully, if scanner finder can find
scanner while scanner link with PC via USB interface well, and then
this icon will show you in resident area of PC Windows system.
This is an icon of Scanner Finder , it means PC Windows system
can not detect scanner has linking successfully, if scanner finder can
not find scanner while scanner link with PC via USB interface, and
then this icon will show you in resident area of PC Windows system.
-
16
Feature List of ScanMaker 3880
MODEL
ITEM
ScanMaker 3880
OPTICAL RESOLUTION 1200dpi(H) * 2400dpi(V)
CARRIAGE STATUS
CARRIAGE DESIGN
WITH SINGLE LENS AND 4 MIRRORS
OPTICAL PATH 1200dpi IN REFLECTIVE MODE
SCAN AREA 8.5 (W) * 11.7 (L) R1200
SAMPLE DEPTH 48 BIT/PIXEL COLOR MODE
16 BIT/PIXEL GRAY MODE
A/D CONVERTER 16BIT A/D CONVERTER IN CHIP : SQ113
CCD TYPE TCD-2905 ( Toshiba CCD )
LAMP TYPE COLD CATHODE LAMP x 1pcs IN CARRIAGE UNIT
MOTOR TYPE MICRO STEPPING MOTOR : 3.75 degree/step
MOTOR DRIVER IC CHIP : 6219
SCANNER CONTROLLER ASIC CHIP : SQ113
USB2.0 CONTROLLER ASIC CHIP : SQ113
DATA PROCESSING CHIP ASIC CHIP : SQ113
IMAGE DATA BUFFER 1M WORD
PROGRAM MEMORY None ( it is driven by S/W : ScanWizard 5 directly )
USB1200 Scanner in S/W Driver SM 3830, SM 3640, SM 3740, SM 3840
USB2400 Scanner in S/W Driver SM 4850, SM 4900
USB2.0 Scanner in S/W Driver SM 5800, SM 5900, SM 5950
USB3200 Scanner in S/W Driver SM 6000, SM 6100
USB ICE Scanner in S/W Driver SM i300, SM i320
3200 Scanner in S/W Driver (SW 5) SM s200
4800 Scanner in S/W Driver (SW 5) SM s400
UF ICE Scanner in S/W Driver SM i700
4800 ICE in S/W Driver ( SW 5 ) SM i410
4800dpi Scanner in S/W Driver SM s430
ScanMaker 4100 in S/W Driver SM 4100
1200dpi Scanner in S/W Driver SM 3880
S/W SUPPORT ( PC version ) ScanWizard 5 V6.113 or its later version for PC Windows system
S/W SUPPORT ( MAC version ) NONE
SCANNER BUTTON FUNCTION 3 BUTTONS FUNCTION :
( Scan / Copy / E-Mail )
POWER ADAPTER ( 12Vdc / 1.25A ) HDAD15W101-124 ( EU / AP, 220VAC, P/N : 545-00-580001)
ACCESSORY OPTION NONE
-
17
The logo of Safety Mark and EMI from power label of SM 3880
The P/N of Power Label for ScanMaker 3880 is 219-21-820000.
In the Power Label of SM 3880, you can find out it get the logo of Safety Mark and EMI as follows :
FCC is the logo of EMI from US.
Energy Star is the logo from Energy Saving Association of US.
ETL is the logo of Safety Mark from US and Canada.
VCCI is the logo of EMI from Japan.
BSMI is the logo of EMI from Taiwan.
CE is the logo of Safety Mark and EMI from EU.
WEEE is the logo of Recovery, Reuse & Recycle from EU
-
18
SYSTEM WIRING DIAGRAM OF ScanMaker 3880
-
19
SYSTEM BLOCK DIAGRAM OF ScanMaker 3880
-
20
WHERE YOU FIND MODEL CODE OF SM 3880 IN S/W DRIVER : ScanWizard 5 V6.113
In SW 5 or in Microtek Scanner Finder, it will tell you the model
code of SM 3880 is 1200dpi Scanner after SM 3880 link with
PC via USB2.0 cable under PC Windows system.
In Scanner Information, it will tell you the model name of
ScanMaker 3880 is called as 1200dpi Scanner .