Download - Meter Reads
Meter Reads
UTILIBILL QUICK START GUIDE
Sys. Ver. 7
28 October 2021
Quick Start Guide: Meter Reads
1
1 OVERVIEW
This document provides a quick start guide in using the Meter Reads function of the Utilibill Web Portal.
1.1 Scope
Before using the Meter Reads function, there must be at least: - An electricity service (could be attached to a customer or vacant) - Active meter/s are attached to the service.
Thus, this document covers:
- Viewing meter reads - Adding meter reads - Importing meter reads.
Note(s):
➢ Creation of services/meters are not in the scope of this document. Please check the related Quick Start Guide for details.
Quick Start Guide: Meter Reads
2
2 VIEW METER READS (BASIC)
2.1 View Meter Reads page
Figure 2-1 Meter Reads tab
Figure 2-2 NEM13 Reads
Figure 2-3 Meter Reads
1
2
3
4
5
6
Quick Start Guide: Meter Reads
3
2.2 View Meter Reads steps
1. From customer’s Overview tab, click Meter Reads tab.
→ Meter Reads page is loaded.
2. Select NMI from Service Name dropdown of the service to be updated.
→ Service Move In Date, Service Move Out Date, and Meter Number fields are updated.
3. Select meter number if needed from Meter Number dropdown.
→ Selected meter number is displayed.
4. Click NEM13 Reads tab in View Reads section.
→ NEM13 Reads sub-section is loaded.
5. Update Date Range From and To fields, and click Retrieve button.
→ Reads are displayed. (Suffix, Register ID, Register Description, Meter Number, Current
DateTime, Usage Quality, Usage Quality Reason, Previous DateTime, Previous Usage, Previous
Usage Quality, Previous Quality Reason, Quantity, Unit of Measure Create Date, Revision Date)
6. Click Meter Reads tab in View Reads section.
→ Meter Reads sub-section is loaded.
→ Meter reads are displayed. (Columns: Meter No, Read Date, Read Type, Meter Read (Flat),
Meter Read (Peak), Meter Read (Off Peak), Meter Read (Shoulder), Units, Datastream, TOU
Number, Comment, Date Added, User Added)
Quick Start Guide: Meter Reads
4
3 VIEW METER READS (INTERVAL)
3.1 View Meter Reads page
Figure 3-1 Meter Reads tab
Figure 3-2 TOU Daily Reads
1
2
3
4
5
Quick Start Guide: Meter Reads
5
Figure 3-3 TOU Reads
Figure 3-4 Demand Reads
8
9
6
7
Quick Start Guide: Meter Reads
6
Figure 3-5 Meter Reads
10
Quick Start Guide: Meter Reads
7
3.2 View Meter Reads steps
1. From customer’s Overview tab, click Meter Reads tab.
→ Meter Reads page is loaded.
2. Select NMI from Service Name dropdown of the service to be updated.
→ Service Move In Date, Service Move Out Date, and Meter Number fields are updated.
3. Select meter number if needed from Meter Number dropdown.
→ Selected meter number is displayed.
4. Click TOU Daily Reads tab in View Reads section.
→ TOU Daily Reads sub-section is loaded.
5. Update Date Range From and To fields, and click Retrieve button.
→ Reads are displayed. (Columns: Date, Day, Total Usage, Import, Billing Status, Usage Quality,
Statement No, Revised Data, Index Read)
6. Click TOU Reads tab in View Reads section.
→ TOU Reads sub-section is loaded.
7. Update Date Range From and To fields, Resolution dropdown, and click Retrieve button.
→ Reads are displayed. (Columns: Suffix, Register ID, Register Description, Meter Number,
DateTime, Usage Quality, Usage Quality Reason, Previous Usage, Previous Usage Quality,
Previous Quality Reason, Adjustment, Create Date, Revision Date)
8. Click Demand Reads tab in View Reads section.
→ Demand Reads sub-section is loaded.
→ Demand reads are displayed if meter has demand reads. (Columns: Service No, Demand
Type, Read Date, Demand Read, Demand Resolution, DST Method Type, Period, TOU Number,
Comment, Date Added, User Added)
9. Refine results by selecting demand type from Select Demand Type dropdown.
→ Only the selected demand types are displayed.
10. Click Meter Reads tab in View Reads section.
→ Meter Reads sub-section is loaded.
→ Meter reads are displayed. (Columns: Meter No, Read Date, Read Type, Meter Read (Flat),
Meter Read (Peak), Meter Read (Off Peak), Meter Read (Shoulder), Units, Datastream, TOU
Number, Comment, Date Added, User Added)
Quick Start Guide: Meter Reads
8
4 ADD METER READS
4.1 Add Meter Reads page
Figure 4-1 Meter Reads tab
Figure 4-2 Meter Reads
1
2
3
4
5
Quick Start Guide: Meter Reads
9
Figure 4-3 Add Read (Flat)'
Figure 4-4 Add Read (POS)
6
6
6
6
Quick Start Guide: Meter Reads
10
4.2 Add Meter Reads steps
1. From customer’s Overview tab, click Meter Reads tab. → Meter Reads page is loaded.
2. Select NMI from Service Name dropdown of the service to be updated. → Service Move In Date, Service Move Out Date, and Meter Number fields are updated.
3. Select meter number if needed from Meter Number dropdown. → Selected meter number is displayed.
4. Click Meter Reads tab in View Reads section. → Meter Reads sub-section is loaded. → Meter reads are displayed. (Columns: Meter No, Read Date, Read Type, Meter Read (Flat), Meter Read (Peak), Meter Read (Off Peak), Meter Read (Shoulder), Units, Datastream, TOU Number, Comment, Date Added, User Added)
5. Click Add Read button. → Add Meter Read dialog is displayed.
6. Input the details of the meter reads, especially the mandatory fields marked with a red asterisk (*).
No. Input Field Note(s)
6a Meter No* Select a meter number
6b Register No / ID Select a register number/ID
6c Datastream* Indicate source datastream Xn. Off-Market meters (non-AEMO) Where X: E = Export (Usage) I = Import (Solar) Where n: 1...9 = Register Number NEM13 meters Where X: 1…9 = Datastream indicator Where n: 1...9, A-H, J-N, P-Z = Meter Numbers
⚠ Important! Correct register information must already be
added into the Utilibill system for NEM13 meters to bill properly.
6d Read Type* Select the read type:
• Initial
• Actual
Quick Start Guide: Meter Reads
11
• Estimate
• Consumption
6e Read Date* Select read date
6f Meter Read (Flat)* Input the meter read (only appears for meters with flat configuration)
6f Meter Read (Peak)* Input the meter read (only appears for meters with POS configuration)
6f Meter Read (Off Peak)*
Input the meter read (only appears for meters with POS configuration)
6f Meter Read (Shoulder)*
Input the meter read (only appears for meters with POS configuration)
6g Rollover Set YES or NO for the toggle to indicate rollover reads
6h Comment Input comments or notes about the reading
7. Click Save button.
→ The new entry is added to the meter reads table.
Quick Start Guide: Meter Reads
12
5 IMPORT METER READS
5.1 Import Meter Reads page
Figure 5-1 Import Setup Tools, Admin page
Figure 5-2 Meter Reads Data Import
3
8
8
7
1
2
Quick Start Guide: Meter Reads
13
Figure 5-3 Meter Reads Import Zip File
Figure 5-4 CSV input
Figure 5-5 Import button
5
9
6
Quick Start Guide: Meter Reads
14
5.2 Import Meter Reads steps
1. In the dashboard, click Admin menu icon.
→ Admin page is loaded.
2. Click Meter Reads icon under Import Setup Tools.
→ Meter Reads Import page is loaded.
3. Click Download Import Template button to download the Excel template for import.
→ Save File popup will be displayed.
4. Click OK button then select a folder where the file will be saved.
→ The zip file should be downloaded successfully.
5. Unzip the download file.
→ The downloaded zip file contains the Excel file template and Word documentation when
unzipped.
6. Follow instructions from the Word documentation and fill up the Meter Read Import Template -
Manual file. Save it.
→ The file is successfully saved.
7. Click Insert File icon and select the saved template.
→ The file name will be displayed under File text input.
8. Input a Description for the import and click Upload File button.
→ The description will be displayed under Import History table.
Quick Start Guide: Meter Reads
15
9. Click on the green Import button.
→ A confirmation message will be shown.
10. Click the OK button.
→ A progress message will be shown.
→ When import is finished, a success message is shown. The meter reads have been
successfully imported.