MAD NETWORK WIRING DIAGRAM
-
MATISSE DIGITAL SIGNAGE/TTG NETWORK WIRING DIAGRAM
120VAC HOT120VAC NEU
GROUND
Shield1Shield2
Terminal Strip
Internet Provided by Building
Network Switch by building
CAT5e installed
by Building
Power from GFCI
Car 1
18GA shielded pair in an Elevator Travelling Cable
Car N
12VPWR-12VPWR+
Matisse
Touchscreen
CAT5e Wired
by MAD
CAT5e Wired
by MAD
CAT5e by elevator contractor
Matisse
12VPWR-12VPWR+
connections and wires by elevator contractor
CAT5e provided by MAD
TypicalArrangement
MACHINE ROOM
MAIN COP AUX COP
2
-
MATISSE DIGITAL SIGNAGE MAIN and AUX COP WIRING DIAGRAM
3
-
Power Supply (ADLS50-12) LCD screen
screen (CVLCD002.156)
Matisse (PMATIS00S.30.02)
HDMI Cable Comes with the screen
MATISSE DIGITAL SIGNAGE MAIN and AUX COP WIRING DIAGRAM
Network Extender (CVLCDMMD1.02)
CAT5e Network cable
(CWH000035.00)
NOTE1: Do not use the power cable that comes with the screen; use the provided power plug. Please ensure that the Matisse player and LCD screen are on the same power supply. For more information, see Appendix.
NOTE2: For mounting instructions, see Appendix.
GROUND 120VAC HOT 120VAC NEU Shield1 Shield2
POWER +POWER-
LPLM
MAIN COP
12VDC INPUT
12VDC INPUT
12VDC INPUT
12VDC OUTPUT
Terminal Strip for AUX
Terminal Strip From Machine Room
LP LM
LM LP
REST MEDIA
NOTE3: For machine room extender unit, please add sticker "To be mounted in machine room". For more information, see Appendix.
(mounted on the back)
4
-
Marquee screen (CVLCD002.156)
Matisse (PMATIS00S.30.02)
HDMI Cable Comes with the screen
(mounted on the back)
AUX COP
12VDC INPUT
12VDC INPUT
PROVIDED BY MAD (CWH000032.00)
POWER-
LPLM
POWER+
LP LM
CAT5e Network cable (Wired on site by elevator contractor)
TerminalStrip FromMain COP
NOTE1: Do not use the power cable that comes with the screen; use the provided power plug. Please ensure that the Matisse player and LCD screen are on the same power supply. For more information, see Appendix.
5
-
MATISSE DIGITAL SIGNAGE MAIN COP WIRING DIAGRAM
6
-
Power Supply (ADLS50-12) LCD screen
screen (CVLCD002.156)
Matisse (PMATIS00S.30.02)
HDMI Cable Comes with the screen
Network Extender (CVLCDMMD1.02)
CAT5e Network cable
(CWH000035.00) (mounted on the back)GROUND 120VAC HOT 120VAC NEU Shield1 Shield2
REST MEDIA
12VDC INPUT
12VDC INPUT
12VDC INPUT
12VDC OUTPUT
LP LM
LM LP
MATISSE DIGITAL SIGNAGE MAIN COP WIRING DIAGRAM
MAIN COP
Terminal Strip From Machine Room
NOTE1: Do not use the power cable that comes with the screen; use the provided power plug. Please ensure that the Matisse player and LCD screen are on the same power supply. For more information, see Appendix.
NOTE2: For mounting instructions, see Appendix.
7
NOTE3: For machine room extender unit, please add sticker "To be mounted in machine room". For more information, see Appendix.
-
TTG NETWORK WIRING DIAGRAM
8
-
Power Supply (XTTG-K00602)
Touchscreen XTTG-K00555
ElevatorInterface
Unit
USB connection
Network Extender (CVLCDMMD1.02)
CAT5e Network cable
MEDIA RESET KEY
GROUND 120VAC HOT 120VAC NEU Shield1 Shield2
Terminal StripFrom Machine
Room
12VDC INPUT
12VDC INPUT
TTG NETWORK WIRING DIAGRAM
NOTE3: For machine room extender unit, please add sticker "To be mounted in machine room". For more information, see Appendix.
NOTE1: Do not use the power cable that comes with the screen; use the provided power plug. Please ensure that the Matisse player and LCD screen are on the same power supply. For more information, see Appendix.
NOTE2: For mounting instructions, see Appendix.
9
-
TTG AND MATISSE DIGITAL SIGNAGE WIRING DIAGRAM
10
-
TTG AND MATISSE DIGITAL SIGNAGE WIRING DIAGRAM
MAIN COP
ElevatorInterface
Unit
Power Supply (XTTG-K00602)
Touchscreen XTTG-K00555
ElevatorInterface
Unit
USB connection
Network Extender (CVLCDMMD1.02)
CAT5e Network cable
MEDIA RESET KEY
120VAC HO120VAC NE
GROUND
Shield1Shield2
Terminal StripFrom Machine
Room
12VDC INPUT
LCD screen screen (CVLCD002.156)
Matisse (PMATIS00S.30.02)
HDMI Cable Comes with the screen
(mounted on the back)
LPLM
LM LP
12VDC INPUT
12VDC INPUT
12VDC INPUT
CAT5e Network cable
NOTE1: Do not use the power cable that comes with the screen; use the provided power plug. Please ensure that the Matisse player and LCD screen are on the same power supply. For more information, see Appendix.
NOTE2: For mounting instructions, see Appendix.
11
NOTE3: For machine room extender unit, please add sticker "To be mounted in machine room". For more information, see Appendix.
-
APPENDIX:MOUNTING & WIRING
INSTRUCTIONS
12
-
NOTE2: Please make sure to mount the Matisse player same as the above picture
with HDMI cable facing towards the input HDMI on
screen
NOTE1: Please use the provided (CWP0000016.00) plug terminal for screen. Wire the positive terminal
to the positive on the power supply and negative to the negative on power supply.
MATISSE
LCD SCREEN
POWER SUPPLY
NOTE3: Please make sure Machine Room extender portion is not loose in
COP back box
Add a note "TO BE INSTALLED IN MACHINE ROOM
CWP0000016.00
CVLCDMMD1.03
Mounting Wiring
13
Machine Room COP
Machine Room: Only Dipswitch 1 on extender should be turned
on COP: All Dipswitches on extender should be turned off
Blank PageBlank PageBlank PageBlank PageBlank PageBlank PageBlank PageBlank PageBlank PageBlank Page