SYNOPSIS OF PRESENTATION
ü Mobile & Fixed Plant / HVAC Filtration Systems- Background. ü It is the “Dust that we can not see” that is the most harmful ü Australian / WHO Workplace Contamination Exposure- Statistics. ü Guidelines, Codes of Practice & Legislation related with Workplace Exposure of Airborne
Particulate/ Fibre. ü Defining PCBU (Person Conducting a Business or Undertaking) under the WHS Act. ü SafeWork- Workplace Particulate & Fibre- OEL Compliance. ü Safework- Workplace Particulate & Fibre- OEL / PEL (Occupation / Personal Exposure Limits). ü Other Health / Safety Considerations- “Its not just all about Dust”. ü Quality Cabin Environmental Air System Design- Consideration, Requirements, Concepts &
Functions:
q The following Presentation provides a brief understanding of:
(2)
§ External Air Filtration / Cabin Pressurisation. § Internal Air- Recirculation Filtration.
§ Design Concepts- Primary Functions § Environmental Differences / Considerations. § Co2 Concentration. ü Filter Elements / Media Explained. ü In- Cabin Sensors / Monitor Alarm Unit. ü QCEA System- How it Works ü QCEA System Technology- Examples. ü QCEA System- Future Developments ü Summary
![Page 3: LSM TECHNOLOGIES SAFETY VIEWING SOLUTIONS · RESPA- HVAC (PFP) Precleaner + Filtration + Pressuriser Technology Presentation Copyright – LSM Technologies . QCEA Systems- Design](https://reader033.vdocuments.mx/reader033/viewer/2022050120/5f5077e5deafa07a5f383c5e/html5/thumbnails/3.jpg)
LSM Technologies- Quality Cabin Environmental Air Systems- "Understanding the Essentials" - Copyright 2015
(3)
Particulate & Fibre Exposure in the Workplace
![Page 4: LSM TECHNOLOGIES SAFETY VIEWING SOLUTIONS · RESPA- HVAC (PFP) Precleaner + Filtration + Pressuriser Technology Presentation Copyright – LSM Technologies . QCEA Systems- Design](https://reader033.vdocuments.mx/reader033/viewer/2022050120/5f5077e5deafa07a5f383c5e/html5/thumbnails/4.jpg)
LSM Technologies- Quality Cabin Environmental Air Systems- "Understanding the Essentials" - Copyright 2015
Mobile & Fixed Plant / HVAC Filtration Systems- Background
q Filtration Panels / Cartridges of conventional Systems are not adequately sealed or / & do not use HEPA Grade Filter Media & so will not provide ALARA or compliancy to OEL Legislation.
q Most Pressurisers are provided for External Air & not for Recirculation Air (Panel Media is non- compliant).
q Mobile / Fixed Plant Cabins are subjected to "dusty" contaminated operating environments- eg Mining, Quarrying, Construction, Earthmoving, Fertiliser, Cement, Agriculture, Timber & many others.
q These environments contain airborne particulate / fibres that can cause severe lung disease & other short & long term health issues.
(4)
![Page 5: LSM TECHNOLOGIES SAFETY VIEWING SOLUTIONS · RESPA- HVAC (PFP) Precleaner + Filtration + Pressuriser Technology Presentation Copyright – LSM Technologies . QCEA Systems- Design](https://reader033.vdocuments.mx/reader033/viewer/2022050120/5f5077e5deafa07a5f383c5e/html5/thumbnails/5.jpg)
Mobile & Fixed Plant HVAC / Filtration Systems- Background
HVAC / Filtration costs to operations are extensive for:
q Frequent Filter Media replacement.
q Labour for Filter Element exchange.
q Electrical Equipment failure & replacement.
q Frequent & premature failure of HVAC
components ($10,000- $30,000 / annum /
machine).
q Associated loss of Production, etc.
q HVAC (Air- conditioning) Systems do not provide
adequate Cabin Filtration or Cabin
Pressurisation.
Internal Recirculation Panel Filter- blocked after only 50 hours.
“Chocked” / failed Evaporator Coil of HVAC
after 250 hours
(5)
LSM Technologies- Quality Cabin Environmental Air Systems- "Understanding the Essentials" - Copyright 2015
![Page 6: LSM TECHNOLOGIES SAFETY VIEWING SOLUTIONS · RESPA- HVAC (PFP) Precleaner + Filtration + Pressuriser Technology Presentation Copyright – LSM Technologies . QCEA Systems- Design](https://reader033.vdocuments.mx/reader033/viewer/2022050120/5f5077e5deafa07a5f383c5e/html5/thumbnails/6.jpg)
LSM Technologies- Quality Cabin Environmental Air Systems- "Understanding the Essentials" - Copyright 2015
It is the “Dust” that we can not see! Airborne Particulate- Fibres
“It is the Dust that we can not see that is the most harmful”- Video- UK Occupational Health & Safety- Dust in Lungs
(6)
![Page 7: LSM TECHNOLOGIES SAFETY VIEWING SOLUTIONS · RESPA- HVAC (PFP) Precleaner + Filtration + Pressuriser Technology Presentation Copyright – LSM Technologies . QCEA Systems- Design](https://reader033.vdocuments.mx/reader033/viewer/2022050120/5f5077e5deafa07a5f383c5e/html5/thumbnails/7.jpg)
STATISTICS / STANDARDS / GUIDELINES / CODES OF PRACTICE
LSM Technologies- Quality Cabin Environmental Air Systems- "Understanding the Essentials" - Copyright 2015
![Page 8: LSM TECHNOLOGIES SAFETY VIEWING SOLUTIONS · RESPA- HVAC (PFP) Precleaner + Filtration + Pressuriser Technology Presentation Copyright – LSM Technologies . QCEA Systems- Design](https://reader033.vdocuments.mx/reader033/viewer/2022050120/5f5077e5deafa07a5f383c5e/html5/thumbnails/8.jpg)
World Health Organisation- Statistics
LSM Technologies- Quality Cabin Environmental Air Systems- "Understanding the Essentials" - Copyright 2015
(8)
q Combined they are the leading cause of deaths in the world. q National Health & Nutrition Examination Survey & American
Thoracic Society estimates that overall 19.2% of COPD cases could be attributed to workplace exposure to contaminants.
q Exposures include organic & inorganic dusts, chemical agents & fumes / exhaust.
q Occupations at high risk are involved in the moving of dirt, crushing of rock, processing of minerals, agricultural, transportation of commodities, etc- all create opportunities for high quantities of respirable dust exposure.
Source: World Health Organisation Data / Strategic Plan for Addressing COPD in
Wisconsin.
q Lung disease in the WHO data (2012) is divided into three categories: ü Chronic Obstructive Pulmonary Disease (COPD), ü Lower Respiratory Infection (LRI), ü Trachea Bronchus & Lung Cancers.
![Page 9: LSM TECHNOLOGIES SAFETY VIEWING SOLUTIONS · RESPA- HVAC (PFP) Precleaner + Filtration + Pressuriser Technology Presentation Copyright – LSM Technologies . QCEA Systems- Design](https://reader033.vdocuments.mx/reader033/viewer/2022050120/5f5077e5deafa07a5f383c5e/html5/thumbnails/9.jpg)
Australian Workplace Contamination Exposure- Statistics
LSM Technologies- Quality Cabin Environmental Air Systems- "Understanding the Essentials" - Copyright 2015
(9)
2010- ISBN 978-0-642-33092- Australian National Hazard Exposure Worker Surveillance Report.
q 39% of Australian workers were exposed to Airborne hazards in the workplace.
q Young workers were more likely to be exposed to airborne hazards than older workers.
q Occupations with the highest likelihoods of exposure to airborne hazards included: Technicians & Trades Workers, Machinery Operators, Drivers & Labourers, etc.
q 23% of workers who reported they were exposed to airborne hazards were not provided with any airborne hazard controls.
q Asthma is rapidly on the rise due to workplace exposure to contaminants Australia.
2000- 2007 Comp Claims for
Respiratory Disease
![Page 10: LSM TECHNOLOGIES SAFETY VIEWING SOLUTIONS · RESPA- HVAC (PFP) Precleaner + Filtration + Pressuriser Technology Presentation Copyright – LSM Technologies . QCEA Systems- Design](https://reader033.vdocuments.mx/reader033/viewer/2022050120/5f5077e5deafa07a5f383c5e/html5/thumbnails/10.jpg)
Standards + References+ Code of Practice- Workplace Exposure
LSM Technologies- Quality Cabin Environmental Air Systems- "Understanding the Essentials" - Copyright 2015
(10)
SafeWork Australia Standards, Guides & Codes of Practices referenced:
q 2012- ISBN 978-0-642-78409: A Guide to the Model SafeWork Health & Safety Act.
q 2012 2013- ISBN 978-1-74361-048: Guide on the Interpretation of Workplace Exposure
Standards for Airborne Contaminants.
q 2013- ISBN 978-1-74361-055: Workplace Exposure Standards for Airborne Contaminants.
q 2011- ISBN 978-0-642-33315: How to Manage & Control Asbestos in the Workplace.
q 2012- SB13-03: Safety Bulletin Diesel Emissions in Mines.
q 2010- ISBN 978-0-642-33092: Australia National Workplace Surveillance Report.
Please note that there maybe other applicable Standards, Codes of Practice, Regulations & the general historical trend is that currently accepted OEL / PEL Exposure Levels are revised / lowered.
![Page 11: LSM TECHNOLOGIES SAFETY VIEWING SOLUTIONS · RESPA- HVAC (PFP) Precleaner + Filtration + Pressuriser Technology Presentation Copyright – LSM Technologies . QCEA Systems- Design](https://reader033.vdocuments.mx/reader033/viewer/2022050120/5f5077e5deafa07a5f383c5e/html5/thumbnails/11.jpg)
Standards + References+ Code of Practice- Workplace Exposure
LSM Technologies- Quality Cabin Environmental Air Systems- "Understanding the Essentials" - Copyright 2015
(11)
q 2013- ISBN 978-1-74361-055: Provides details on the frequency of sampling, record keeping
& other details on PEL (Personal) / OEL (Occupational) Exposure Limits.
ü OEL / PEL must be frequently recorded & records kept for 30 years after the date the
record is made.
ü Details are readily accessible to persons at the workplace who may be exposed to a
substance or mixture.
ü This Standard also lists the various types of Contaminants & their OEL / PEL (Exposure
Limits) based upon a TWA 8 hours working period. For longer working shift this limits are
reduced according to (eg) Brief & Scala calculation for extended working hours.
q 2013- ISBN 978-1-74361-048: Provides guidance on the interpretation of workplace
Exposure Standards for Airborne Contaminants which reiterates & discusses in more detail
the 013- ISBN 978-1-74361-055.
![Page 12: LSM TECHNOLOGIES SAFETY VIEWING SOLUTIONS · RESPA- HVAC (PFP) Precleaner + Filtration + Pressuriser Technology Presentation Copyright – LSM Technologies . QCEA Systems- Design](https://reader033.vdocuments.mx/reader033/viewer/2022050120/5f5077e5deafa07a5f383c5e/html5/thumbnails/12.jpg)
Standards + References+ Code of Practice- Workplace Exposure
LSM Technologies- Quality Cabin Environmental Air Systems- "Understanding the Essentials" - Copyright 2015
(12)
q 2011- ISBN 978-0-642-33315 & 2012- SB13-03 Diesel Emissions in Mines: Standards / Bulletin is related to Asbestos Exposure + DPM (Diesel Particulate Matter) Exhaust (carcinogens).
q 2010- ISBN 978-0-642-33092: Provides statistics / issues for Exposure to Dust (Particulate), Gases, Vapours, Smoke, Fumes & the provision of implementing Control Measures for Airborne Hazards in Australian workplaces.
q 2012- ISBN 978-0-642-78409 Guide- WHS Act 2012 (WHS Act – Mines- 2014): ü Defines a PCBU as a “Person Conducting a Business or Undertaking”. ü PCBU’s are part of the "Chain of Accountability" or "Chain or Responsibility“. ü PCBU’s are Suppliers, Designers, Importers, Manufacturers, Responsible Individuals-
LSM Technologies & You are PCBU’s. ü Non- Compliance carries severe penalties.
![Page 13: LSM TECHNOLOGIES SAFETY VIEWING SOLUTIONS · RESPA- HVAC (PFP) Precleaner + Filtration + Pressuriser Technology Presentation Copyright – LSM Technologies . QCEA Systems- Design](https://reader033.vdocuments.mx/reader033/viewer/2022050120/5f5077e5deafa07a5f383c5e/html5/thumbnails/13.jpg)
RESPA- HVAC (PFP)- SD + SDX + ICPSensor- ESSENTIALS Presentation Copyright – LSM Technologies
OEL compliance is not just for RCS (Respirable Crystalline Silica)- but also other Particulate & Fibres that are Respirable such as asbestos, nickel, alumina, DPM (Diesel Particulate Matter), etc. The 2013- ISBN 978-1-74361-
055: Workplace Exposure Standards should be referenced to ascertain respective OEL limits.
q The current Australian SafeWork Standards ( legislates exposure limits: üFor RCS is < 0.1 mg / m3 Air Breathed TWA (Time Weighted Average) for a 8 hour shift. üAsbestos 0.1 Fibre / ml & L/ W ratio of 3:1, DPM as for RCS- MDG29- not published). üA 12 hour shift using the Brief & Scala adjusted calculation, RCS OEL < 0.05 mg/ M3
(TWA). üTesting is to be recorded / completed frequently- MSHA (USA) have implemented CPM
(Continuous Particulate Monitoring) for Coal Mines.
Safework- Workplace Particulate & Fibre- OEL Compliance
q To achieve Compliance: üAll Respirable Particulate >0.3u be removed @ 99.97% arrestance (AS 4260-1997). üIn the case of Fibre / DPM (carcinogens) exposure- HEPA Filter Media of >H13 / H14
must be used (EN1822 Standards).
(13)
LSM Technologies- Quality Cabin Environmental Air Systems- "Understanding the Essentials" - Copyright 2015
q Testing is completed according to:
üAS3640-2009 Workplace atmosphere- Method for sampling of inhalable dust.
üAS 2985-2009: Workplace atmospheres – Method for sampling - respirable dust
![Page 14: LSM TECHNOLOGIES SAFETY VIEWING SOLUTIONS · RESPA- HVAC (PFP) Precleaner + Filtration + Pressuriser Technology Presentation Copyright – LSM Technologies . QCEA Systems- Design](https://reader033.vdocuments.mx/reader033/viewer/2022050120/5f5077e5deafa07a5f383c5e/html5/thumbnails/14.jpg)
Other Health / Safety Considerations- “It’s not just all about Dust”
LSM Technologies- Quality Cabin Environmental Air Systems- "Understanding the Essentials" - Copyright 2015
(14)
Other aspects of Compliance, OH&S issues that need to be considered are: q CO2 Concentration: (AIRAH: 700- 1,000 ppm limits) drowsiness, loss of concentration,
fatigue, micro- sleeps, acidosis.
q Exhaust Air Flows: Fresh Air (Exhaust Air) Flow is required to off- set Co2- AIRAH 10-15 l / seconds (20-30 Cfm) / Occupant.
q Optimising Operator Thermal conditions: Avoids Fatigue & Micro- sleeps, enhances Productivity.
q Rapid Filtration of Recirculation Air: Entrapped Contamination enters via Operators clothing / boots, opening of doors / windows, etc (20-30 / hour Volume of Cabin).
Cabin Pressurisation:
q There is no Australian Standard for minimum / maximum Cabin Pressurisation.
q NIOSH1 states “reasonable range” 20-60 pascal (although tests have shown that at 60 kph=
external Wind pressure of 100 pascal).
q EN474-1:2014-03- Earthmoving Machinery Safety- Part 1 states 50 pascal.
q LSM suggest >80 pascal with optimum between 120-150 pascal / 200 maximum. NIOSH1 Source: H&S Workshop Key Cab Factors NIOSH Presentation 2013
![Page 15: LSM TECHNOLOGIES SAFETY VIEWING SOLUTIONS · RESPA- HVAC (PFP) Precleaner + Filtration + Pressuriser Technology Presentation Copyright – LSM Technologies . QCEA Systems- Design](https://reader033.vdocuments.mx/reader033/viewer/2022050120/5f5077e5deafa07a5f383c5e/html5/thumbnails/15.jpg)
Lung Foundation of Australia “Check in with your Lungs”
LSM Technologies- Quality Cabin Environmental Air Systems- "Understanding the Essentials" - Copyright 2015
(15)
“Check in with Your Lungs”
q Commercial run
during February-
April 2014 by the
Lung Foundation
of Australia. q Poor Lung Health
effects 1 in every 10
Australians.
![Page 16: LSM TECHNOLOGIES SAFETY VIEWING SOLUTIONS · RESPA- HVAC (PFP) Precleaner + Filtration + Pressuriser Technology Presentation Copyright – LSM Technologies . QCEA Systems- Design](https://reader033.vdocuments.mx/reader033/viewer/2022050120/5f5077e5deafa07a5f383c5e/html5/thumbnails/16.jpg)
LSM Technologies- Quality Cabin Environmental Air Systems- "Understanding the Essentials" - Copyright 2015
QUALITY CABIN ENVIRONMENTAL AIR SYSTEMS
DESIGN REQUIREMENTS, CONCEPTS & FUNCTIONS
![Page 17: LSM TECHNOLOGIES SAFETY VIEWING SOLUTIONS · RESPA- HVAC (PFP) Precleaner + Filtration + Pressuriser Technology Presentation Copyright – LSM Technologies . QCEA Systems- Design](https://reader033.vdocuments.mx/reader033/viewer/2022050120/5f5077e5deafa07a5f383c5e/html5/thumbnails/17.jpg)
Fresh Air Supply / Co2
Concentration / Exhaust Air
Flow
Optimise Cabin Pressurisation >80- Optimum 120-150 / 200 Max Pascal
Flow Limitations for HEPA
Media Integrity
Additional Flow Rate to
reduce Vehicle Leakage work.
Quick Filtration of
Recirculation / Internal Air
Optimum Thermal
Efficiency / Operator Comfort
Maximise Filter
Service Life
Maximise HVAC
Service Life + Functions
LSM Technologies- Quality Cabin Environmental Air Systems- "Understanding the Essentials" - Copyright 2015
Differences in Cabin Type /
Operating Parameters- eg LVehicle / HME
/ Crusher Cabin
Quality Cabin Environmental Systems- Design Concepts
Exposure Compliance /
Maximise Health
![Page 18: LSM TECHNOLOGIES SAFETY VIEWING SOLUTIONS · RESPA- HVAC (PFP) Precleaner + Filtration + Pressuriser Technology Presentation Copyright – LSM Technologies . QCEA Systems- Design](https://reader033.vdocuments.mx/reader033/viewer/2022050120/5f5077e5deafa07a5f383c5e/html5/thumbnails/18.jpg)
RESPA- HVAC (PFP) Precleaner + Filtration + Pressuriser Technology Presentation Copyright – LSM Technologies
QCEA Systems- Design Concepts- Primary Functions (18)
LSM Technologies- Quality Cabin Environmental Air Systems- "Understanding the Essentials" - Copyright 2015
Fresh Air Supply / Co2
Concentration / Exhaust Air
Flow
[Fresh / Clean Air into the Cabin. [Compliant to SafeWork Standards (Merv16+ or HEPA >H13 / H14). [Same Filtration Media- both for External & Recirculation Air. [Offset Co2 Concentration (AIRAH 700 / 1,000 ppm). [Exhaust Air (AIRAH 10-15 l/s / Occupant).
Maximise Filter Service
Life
Flow Limitations for HEPA Media
Integrity
Additional Flow Rate to
reduce Vehicle Leakage work.
[ Increased Flow Rate- reduce Sealing Work to the Cabin. [Keep within limitations of Filter Media. [Care not to “agitate” settled Contaminates (eg floor, windows, dash,
seats, etc)- do not desire a “tornado” in Cabin. [Keep within limitations of Filter Media. [HEPA is fragile- HEPA Media is normally designed as Panel Filters
for Static Enclosures- eg Buildings- not Mobile Plant (vibration, machine movement, temperature, high air flows / velocity, etc).
[ Increased Flow Rate can lower Arrestance Efficiency, Damage Media- shorten Service Life of Filter.
[ Increased Flow Rate- reduces Filter Service Life. [Quicker loading of Filter & premature Damage.
![Page 19: LSM TECHNOLOGIES SAFETY VIEWING SOLUTIONS · RESPA- HVAC (PFP) Precleaner + Filtration + Pressuriser Technology Presentation Copyright – LSM Technologies . QCEA Systems- Design](https://reader033.vdocuments.mx/reader033/viewer/2022050120/5f5077e5deafa07a5f383c5e/html5/thumbnails/19.jpg)
RESPA- HVAC (PFP) Precleaner + Filtration + Pressuriser Technology Presentation Copyright – LSM Technologies
QCEA Systems- Design Concepts- Primary Functions (19)
LSM Technologies- Quality Cabin Environmental Air Systems- "Understanding the Essentials" - Copyright 2015
[Rapidly remove entrapped Airborne Contamination (20-30 / Hour of Cabin Volume) especially due to ingress from opening of Doors, Windows, Operator Clothing, Machine movement / agitation of settled contamination- not to be used as “vacuum cleaner”.
Optimise Cabin Pressurisation >80- Optimum 120-150 / 200 Max Pascal
Quick Filtration of Recirculation /
Internal Air
Optimum Thermal Efficiency /
Operator Comfort
Maximise HVAC Service Life +
Functions
[Over Pressurisation (>200 pascal) may cause pain to Operators ears, undue pressure on Windows & permanent distortion of Seals.
[ Increased thermal comfort means enhanced productivity / reduced risk of micro- sleeps / fatigue.
[Quicker cabin Cooling- less potential for opening of Doors & Windows whilst in use.
[Higher arrestance efficiency= less inundation to Fan & Evaporator.
[Additional “Chiller” Dual Air- conditioning= less loading of Compressor- longer service life.
![Page 20: LSM TECHNOLOGIES SAFETY VIEWING SOLUTIONS · RESPA- HVAC (PFP) Precleaner + Filtration + Pressuriser Technology Presentation Copyright – LSM Technologies . QCEA Systems- Design](https://reader033.vdocuments.mx/reader033/viewer/2022050120/5f5077e5deafa07a5f383c5e/html5/thumbnails/20.jpg)
RESPA- HVAC (PFP) Precleaner + Filtration + Pressuriser Technology Presentation Copyright – LSM Technologies
QCEA Systems- Environmental Differences / Considerations (20)
LSM Technologies- Quality Cabin Environmental Air Systems- "Understanding the Essentials" - Copyright 2015
Light Vehicles. [Higher Co2 Concentration: Multiple Occupants- 1 x Occupant >3,000
ppm in 8 minutes. [Higher Thermal Loading: More occupants, frequent stand still (latent
heat build- up),smaller HVAC. [Recirculation Air Filtration: Quicker Contamination removal- more
frequent opening of Doors & Windows (ingress / egress)- Inundation.
Differences
in Cabin Type /
Operating Parameters
Eg LVehicle /
HME / Crusher Cabin
/Electrical Cabinets,
etc.
HME Vehicles. [ Less Co2 Concentration: Usually Single Occupant. [ Lower Thermal Loading: Usually operational full shift. [Recirculation Air Filtration: Less frequent opening of Doors, etc.
Crusher / Static Cabins. [ Larger Area / Cabin Volume. [Frequent Open of Doors / Inundation. [Higher developed internal Temperatures- Static Building.
![Page 21: LSM TECHNOLOGIES SAFETY VIEWING SOLUTIONS · RESPA- HVAC (PFP) Precleaner + Filtration + Pressuriser Technology Presentation Copyright – LSM Technologies . QCEA Systems- Design](https://reader033.vdocuments.mx/reader033/viewer/2022050120/5f5077e5deafa07a5f383c5e/html5/thumbnails/21.jpg)
How Important is Co2 Concentration?
[QCEA System must never be designed to allow 100% Recirculation Air otherwise Co2 Concentration, Under- Pressurisation & Contamination of Cabin.
[ It is best practice that the QCEA System is never turned off when occupied so as to ensure that there is a continuous flow of "blended" fresh / external air, at all times.
[An In- Cabin Sensor Warning Unit should be used to monitor Cabin Pressurisation (Filter Loading / Air Flow) to ensure Fresh Air / Positive Cabin Air is supplied at all times.
Simulate Blocked Filter- Recirculation Air Only
Cabin De- pressurised
Co2 > 4,000 ppm in 25 minutes. Max allowable is TWA 1,000
External Filter Un- blocked Co2 to 400- 600 ppm in 5 minutes.
Cabin Re- pressurised
(21)
LSM Technologies- Quality Cabin Environmental Air Systems- "Understanding the Essentials" - Copyright 2015
![Page 22: LSM TECHNOLOGIES SAFETY VIEWING SOLUTIONS · RESPA- HVAC (PFP) Precleaner + Filtration + Pressuriser Technology Presentation Copyright – LSM Technologies . QCEA Systems- Design](https://reader033.vdocuments.mx/reader033/viewer/2022050120/5f5077e5deafa07a5f383c5e/html5/thumbnails/22.jpg)
How Important is: Co2 Concentration?
[Video we demonstrate how Co2 levels can concentrate quickly from the respiration of the occupants inside the Cabin.
[Unacceptable Co2 concentration (> 700- 1,000 ppm) has proven to effect Concentration, cause Fatigue / Micro- sleeps, etc & in severe cases Acidosis.
[AIHRA recommend "Exhaust Air Leakage"- Fresh Air displacement- 10- 15 litres / second for each Occupant inside a Cabin.
[More Occupants- eg Light Vehicles / Buses require increased External Air Flow to off- set Co2.
(22)
LSM Technologies- Quality Cabin Environmental Air Systems- "Understanding the Essentials" - Copyright 2015
[ It would be reasonable to presume that if Phil was working normally the his respiratory rate would be higher with Co2 concentration being even more excessive and increasing more quickly.
![Page 23: LSM TECHNOLOGIES SAFETY VIEWING SOLUTIONS · RESPA- HVAC (PFP) Precleaner + Filtration + Pressuriser Technology Presentation Copyright – LSM Technologies . QCEA Systems- Design](https://reader033.vdocuments.mx/reader033/viewer/2022050120/5f5077e5deafa07a5f383c5e/html5/thumbnails/23.jpg)
How Important is: Cabin Pressurisation / External Air Filtration
[Video demonstrates efficiency of QCEA System excludes Contamination entering the Cabin- filtering External Air to HEPA >H13 / H14 levels of 99.995% @ 0.3 micron.
[ Inadequate (lower than external pressure) or Negative Cabin Pressure will allow contamination enter Cabin.
[Cabin pressure >80 pascal, optimum 120-150 pascal & maximum 200 Pascal.
[Over- pressure damages / permanently deforms Cabin Seals allowing ingress of Contamination when the Machine / QCEA System stopped.
[Cabin Over- pressure also risks discomfort to the Operator / damaging Ears.
(23)
LSM Technologies- Quality Cabin Environmental Air Systems- "Understanding the Essentials" - Copyright 2015
[ Important to monitor the Cabin Pressure using a In- Cabin Sensor / Alarm Monitor so as Positive Cabin Pressure is maintained at all times.
![Page 24: LSM TECHNOLOGIES SAFETY VIEWING SOLUTIONS · RESPA- HVAC (PFP) Precleaner + Filtration + Pressuriser Technology Presentation Copyright – LSM Technologies . QCEA Systems- Design](https://reader033.vdocuments.mx/reader033/viewer/2022050120/5f5077e5deafa07a5f383c5e/html5/thumbnails/24.jpg)
How Important is: Recirculation Air Filtration
[Video demonstrates the efficiency of the QCEA System Recirculation Filtration Unit to remove Entrapped Airborne Contamination by filtering to HEPA >H13 / H14 levels of 99.995% @ 0.3 micron Contamination from within the Cabin.
[Phil creates Airborne Particulate Events by rubbing his clothing, moving his feet- even rubbing his skin / hair.
[Contaminants also become Airborne with Machine / Operator movement.
[ Larger events mass concentration levels were >3.0 mg / m3 smaller events <0.2 mg / m3 (OEL for RCS should be <0.05 mg / m3 TWA for a 12 hour days).
(24)
LSM Technologies- Quality Cabin Environmental Air Systems- "Understanding the Essentials" - Copyright 2015
[The QCEA Recirculation Unit rapidly filters Events to 0.000 mg / m3, depending on severity- within seconds!
[Reduces exposure to the Operator / Occupants.
![Page 25: LSM TECHNOLOGIES SAFETY VIEWING SOLUTIONS · RESPA- HVAC (PFP) Precleaner + Filtration + Pressuriser Technology Presentation Copyright – LSM Technologies . QCEA Systems- Design](https://reader033.vdocuments.mx/reader033/viewer/2022050120/5f5077e5deafa07a5f383c5e/html5/thumbnails/25.jpg)
How Important is: Recirculation Air Filtration- Extreme Test [Video demonstrates the efficiency
of the LSM Technologies Quality Cabin Environmental Air System's RESPA® Recirculation Filtration Unit (HEPA >H13 / H14) This is an extreme test with a more representative test of real Operating conditions demonstrated in the RESPA Recirculation Filtration of Entrapped Contamination Test Video.
[A Smoke Emitter of 18 x m3 with Particulate size of 0.3 micron is ignited inside the Cabin.
[Smoke Emitter produced Airborne Contamination levels of mass concentration 200 x times that of any OEL.
(25)
LSM Technologies- Quality Cabin Environmental Air Systems- "Understanding the Essentials" - Copyright 2015
[After <2.0 minutes testing Cabin was visually clear of contamination- however still > acceptable levels.
[After 5.0 minutes Airborne Contamination dropped to H13 / H14 HEPA levels >99.995% efficiency & mass concentration of 0.000 mg / m3.
![Page 26: LSM TECHNOLOGIES SAFETY VIEWING SOLUTIONS · RESPA- HVAC (PFP) Precleaner + Filtration + Pressuriser Technology Presentation Copyright – LSM Technologies . QCEA Systems- Design](https://reader033.vdocuments.mx/reader033/viewer/2022050120/5f5077e5deafa07a5f383c5e/html5/thumbnails/26.jpg)
Filter Elements / Media Explained (26)
HEPA is High Efficiency Particulate Air (Arrestance) according to:
q AS 4260-1997: is 0.3 micron @ 99.97% Arrestance or 0.03% Volumetric Penetration.
q EN1822: H Class- typically H12 to H14- especially used for Fibrous Materials / DPM.
q Sy- klone HEPA Filter Elements are >H13 Class but achieve >H14 Class which is
Arrestance of >99.995 or Volumetric Penetration of <0.005 %.
q Typical MPPS (Maximum Penetrating Particle Size) is 0.25- 0.3.
q Arrestance Efficiency must be at manufactures flow rate- Sy- klone >H13 Filter Elements
are compliant at Flow Rates of (50- 75 litre/ sec (100- 150 cfm).
LSM Technologies- Quality Cabin Environmental Air Systems- "Understanding the Essentials" - Copyright 2015
![Page 27: LSM TECHNOLOGIES SAFETY VIEWING SOLUTIONS · RESPA- HVAC (PFP) Precleaner + Filtration + Pressuriser Technology Presentation Copyright – LSM Technologies . QCEA Systems- Design](https://reader033.vdocuments.mx/reader033/viewer/2022050120/5f5077e5deafa07a5f383c5e/html5/thumbnails/27.jpg)
Filter Elements / Media- Explained (27)
LSM Technologies / Sy- klone RESPA CF / CFX Filter Elements are: q RESPA CF (External Air)- Ported Ejection Filter Element.
q RESPA CFX (Recirculation Air)- Non-Ported / Closed Element.
q Robust in construction & “fit- for purpose” for Mobile Plant.
q Service Life> 500- 1,000 hours.
q Ensure the correct Filter Element is in the correct RESPA Unit.
q Filter Elements should not be used >1,000 hours so as to avoid deterioration & entry of contamination into Cabin / HVAC Systems.
RESPA CFX Recirculation Air Filter Elements- note that this is Non- Ported
RESPA CF External Air Filter Elements- note that the black
end has Ejection Ports
Special Notes: [Filter Elements should not be “Washed” / Re- used.
[Always ensure that Supplier provides DOP Certification of the complete QCEA System by DOP Testing at >H13 / H14 class inside the Cabin- after installation of the System- do not accept supplier statement that their Filter Media or System is “HEPA”.
[DOP Testing is referred to as “Dispersed Oil Particulate Test” as per ISO / EN1822 Standard.
LSM Technologies- Quality Cabin Environmental Air Systems- "Understanding the Essentials" - Copyright 2015
![Page 28: LSM TECHNOLOGIES SAFETY VIEWING SOLUTIONS · RESPA- HVAC (PFP) Precleaner + Filtration + Pressuriser Technology Presentation Copyright – LSM Technologies . QCEA Systems- Design](https://reader033.vdocuments.mx/reader033/viewer/2022050120/5f5077e5deafa07a5f383c5e/html5/thumbnails/28.jpg)
RESPA- HVAC (PFP) Precleaner + Filtration + Pressuriser Technology Presentation Copyright – LSM Technologies
Cabin Pressurisation- Importance of a- In- Cabin Alarm Monitor (28)
LSM Technologies- Quality Cabin Environmental Air Systems- "Understanding the Essentials" - Copyright 2015
When to change a Filter Element:
q Use a In- Cabin Pressure Sensor to monitor the cabin
Pressurisation.
q Once Cabin Set- point Pressure is known then Alarm
Threshold should be between 20-40 pascal below the
achieved set- point.
q Alarms setting should signify Filter Element Exchange.
In- Cabin Pressure Sensor Alarm will:
q Alarm to signify a change in Cabin Pressure (below Alarm threshold).
q Change in Cabin Pressure will be cause due to Opening of Doors / Windows, Leaking Seals
but predominantly when Filter Element becomes loaded.
Note: It is essential that the Vehicle Alternator meets the requirements for power draw (at engine idle) of the QCEA System otherwise fluctuation in Cabin Pressure will occur with false alarming.
![Page 29: LSM TECHNOLOGIES SAFETY VIEWING SOLUTIONS · RESPA- HVAC (PFP) Precleaner + Filtration + Pressuriser Technology Presentation Copyright – LSM Technologies . QCEA Systems- Design](https://reader033.vdocuments.mx/reader033/viewer/2022050120/5f5077e5deafa07a5f383c5e/html5/thumbnails/29.jpg)
LSM Technologies- Quality Cabin Environmental Air Systems- "Understanding the Essentials" - Copyright 2015
QUALITY CABIN ENVIRONMENTAL (QCEA) SYSTEM TECHNOLOGY
“ HOW IT WORKS”
MOBILE & FIXED PLANT CABINS
![Page 30: LSM TECHNOLOGIES SAFETY VIEWING SOLUTIONS · RESPA- HVAC (PFP) Precleaner + Filtration + Pressuriser Technology Presentation Copyright – LSM Technologies . QCEA Systems- Design](https://reader033.vdocuments.mx/reader033/viewer/2022050120/5f5077e5deafa07a5f383c5e/html5/thumbnails/30.jpg)
LSM Technologies- Quality Cabin Environmental Air Systems- "Understanding the Essentials" - Copyright 2015
How it Works- RESPA(Tm) External Air Unit- Precleaning (30)
[Contaminated laden Air enters the Unit Inlet. [ 2. The Fan creates a VORTEX, a tornado-like
spinning motion, whipping the Air & Contaminant to the outside wall.
[ 3. Spinning Air HYPER-accelerates as it passes through Louvers, further enhancing centrifugal forces powerful enough to affect Contaminant Separation.
[ 4. Contaminant is spun against the outside wall of the Unit & propelled rapidly around the Filter to the rear of the Unit. 5. Contamination is ejected back into the environment via the Ejection Ports .
[ 6. Precleaned Air passes through the Filter & continues to the Outlet.
1. External Air Entry
2. Precleaner Ejects >97% Debris back into
Environment
3. Fresh Filtered Air to HEPA >H13 / H14 to
Cabin
q The External RESPA™ extends Filter Element Service Life by >10 due to its unique & patented Precleaning Technology
![Page 31: LSM TECHNOLOGIES SAFETY VIEWING SOLUTIONS · RESPA- HVAC (PFP) Precleaner + Filtration + Pressuriser Technology Presentation Copyright – LSM Technologies . QCEA Systems- Design](https://reader033.vdocuments.mx/reader033/viewer/2022050120/5f5077e5deafa07a5f383c5e/html5/thumbnails/31.jpg)
LSM Technologies- RESPA Quality Cabin Environmental Air Systems- "Understanding the Essentials" - Copyright 2015
How it Works- Quality Cabin Environmental Air (QCEA) System (31)
Recirculation + External Air
Mixing Plenum
Blower Assist Unit
RESPA CFX Recirculation Air Unit- Cleans the Air from the
Cabin
Chiller / Secondary Air- Conditioning Unit- High
Ambien's (optional)
RESPA CF External Air Unit- Cleans External Air +
Pressurisation of Cabin
Precleaner Ejects Debris back into
Environment
LSM Technologies- Quality Cabin Environmental Air Systems- "Understanding the Essentials" - Copyright 2015
![Page 32: LSM TECHNOLOGIES SAFETY VIEWING SOLUTIONS · RESPA- HVAC (PFP) Precleaner + Filtration + Pressuriser Technology Presentation Copyright – LSM Technologies . QCEA Systems- Design](https://reader033.vdocuments.mx/reader033/viewer/2022050120/5f5077e5deafa07a5f383c5e/html5/thumbnails/32.jpg)
How it Works- Mining / Construction Machines (32)
LSM Technologies- Quality Cabin Environmental Air Systems- "Understanding the Essentials" - Copyright 2015
RESPA CF External Air Unit
RESPA CFX Recirculation Air Unit
Ejected Debris / Precleaned Air
In-Cabin Pressure Sensor
![Page 33: LSM TECHNOLOGIES SAFETY VIEWING SOLUTIONS · RESPA- HVAC (PFP) Precleaner + Filtration + Pressuriser Technology Presentation Copyright – LSM Technologies . QCEA Systems- Design](https://reader033.vdocuments.mx/reader033/viewer/2022050120/5f5077e5deafa07a5f383c5e/html5/thumbnails/33.jpg)
How it Works- Service Trucks (33)
LSM Technologies- Quality Cabin Environmental Air Systems- "Understanding the Essentials" - Copyright 2015
![Page 34: LSM TECHNOLOGIES SAFETY VIEWING SOLUTIONS · RESPA- HVAC (PFP) Precleaner + Filtration + Pressuriser Technology Presentation Copyright – LSM Technologies . QCEA Systems- Design](https://reader033.vdocuments.mx/reader033/viewer/2022050120/5f5077e5deafa07a5f383c5e/html5/thumbnails/34.jpg)
How it Works- Light Vehicles (34)
LSM Technologies- Quality Cabin Environmental Air Systems- "Understanding the Essentials" - Copyright 2015
![Page 35: LSM TECHNOLOGIES SAFETY VIEWING SOLUTIONS · RESPA- HVAC (PFP) Precleaner + Filtration + Pressuriser Technology Presentation Copyright – LSM Technologies . QCEA Systems- Design](https://reader033.vdocuments.mx/reader033/viewer/2022050120/5f5077e5deafa07a5f383c5e/html5/thumbnails/35.jpg)
How it Works- Fixed Plant Cabins / Electrical Enclosures (35)
LSM Technologies- Quality Cabin Environmental Air Systems- "Understanding the Essentials" - Copyright 2015
![Page 36: LSM TECHNOLOGIES SAFETY VIEWING SOLUTIONS · RESPA- HVAC (PFP) Precleaner + Filtration + Pressuriser Technology Presentation Copyright – LSM Technologies . QCEA Systems- Design](https://reader033.vdocuments.mx/reader033/viewer/2022050120/5f5077e5deafa07a5f383c5e/html5/thumbnails/36.jpg)
LSM Technologies- Quality Cabin Environmental Air Systems- "Understanding the Essentials" - Copyright 2015
QUALITY CABIN ENVIRONMENT AIR SYSTEMS
FUTURE DEVELOPMENTS
![Page 37: LSM TECHNOLOGIES SAFETY VIEWING SOLUTIONS · RESPA- HVAC (PFP) Precleaner + Filtration + Pressuriser Technology Presentation Copyright – LSM Technologies . QCEA Systems- Design](https://reader033.vdocuments.mx/reader033/viewer/2022050120/5f5077e5deafa07a5f383c5e/html5/thumbnails/37.jpg)
Quality Cabin Environment Air System- Future Developments
LSM Technologies- Quality Cabin Environmental Air Systems- "Understanding the Essentials" - Copyright 2015
(37)
q Co2, CO & Temperature Sensor Integration.
q Particulate Monitoring for mass concentration.
qWeb Based Fleet tracking / Maintenance Management Software that will provide:
ü Live Telemetry collection of Data- Cabin Pressure, Co / Co2 Levels, Temperature.
ü Analysis & Reporting for each Vehicle Cabin Environmental conditions.
ü Warning for Filter Exchange.
ü Recording of Data to validate compliance & corrective actions as required- eg
Opening of Windows, Smoking in Cabin, etc.
Future Developments for Quality Cabin Environmental Air Systems:
![Page 38: LSM TECHNOLOGIES SAFETY VIEWING SOLUTIONS · RESPA- HVAC (PFP) Precleaner + Filtration + Pressuriser Technology Presentation Copyright – LSM Technologies . QCEA Systems- Design](https://reader033.vdocuments.mx/reader033/viewer/2022050120/5f5077e5deafa07a5f383c5e/html5/thumbnails/38.jpg)
Quality Cabin Environmental Air Systems- Summary
LSM Technologies- Quality Cabin Environmental Air Systems- "Understanding the Essentials" - Copyright 2015
(38)
q Consider compliance requirements to Australia (& International Standards).
q Keep abreast of changes in SafeWork Exposure to Airborne Contaminants & WHS Standards as there is an intensified focus in Compliance & lowering of OEL / PEL.
q Conduct frequent OEL & PEL Sampling & good Records- for 30 years.
q Consider who is in the “Chain of Accountability” as a PCBU under WHS Act.
q HEPA Filter Media does not necessarily make a HEPA System- ensure that the complete System is DOP Certified to >H13 / H14 after Installation & meets subsequent testing between Filter Element replacement.
q Ensure that the QCEA System is designed “fit- for- purpose” considering not just Contaminant Exposure but all other OH&S parameters (Pressurisation, Co2 Exhaust, etc) / Operational / Machine conditions.
q Ensure that your QCEA System Supplier guarantees System Compliance.
q On- going management of implemented QCEA System Control Measures is critical to maintain Compliance.
q Include your QCEA System Supplier in your management processes to continuously improve OH&S for Workplace Airborne Particulate / Fibre Exposure.
![Page 39: LSM TECHNOLOGIES SAFETY VIEWING SOLUTIONS · RESPA- HVAC (PFP) Precleaner + Filtration + Pressuriser Technology Presentation Copyright – LSM Technologies . QCEA Systems- Design](https://reader033.vdocuments.mx/reader033/viewer/2022050120/5f5077e5deafa07a5f383c5e/html5/thumbnails/39.jpg)
RESPA- HVAC (PFP) Precleaner + Filtration + Pressuriser Technology Presentation Copyright – LSM Technologies
RESPA- Applications
[ Cranes.
[ Drill Rigs
[ Emergency Vehicles.
[ Council Vehicles.
[ Agricultural machines
[ Garbage Trucks.
[ Landfill Operations.
[ Military.
[ & many more…….!
Mobile + Fixed Cabins / Industries:
[Crusher Cabins.
[High Voltage Electrical Cabinets.
[Compressor Compartments.
[Electric Motors / Alternators / Drives.
[Electrical Control Rooms.
[& Many More……..!
Many other Applications:
(39)
LSM Technologies- Quality Cabin Environmental Air Systems- "Understanding the Essentials" - Copyright 2015
![Page 40: LSM TECHNOLOGIES SAFETY VIEWING SOLUTIONS · RESPA- HVAC (PFP) Precleaner + Filtration + Pressuriser Technology Presentation Copyright – LSM Technologies . QCEA Systems- Design](https://reader033.vdocuments.mx/reader033/viewer/2022050120/5f5077e5deafa07a5f383c5e/html5/thumbnails/40.jpg)
LSM Technologies- Quality Cabin Environmental Air Systems- "Understanding the Essentials" - Copyright 2015
THANK YOU- Visit our Web Site: www.lsmtechnologies.com.au