3/04 Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document.
N/UK 1.5.149.01
LPDA/182000, LPDA/182000/MLow temperature cylinders
with or without magnetic pistonDouble acting
Ø 32 to 125 mm
To be suited to -40°C
Special polyurethane wiper seal
Lightweight profile design with concealed tie rods
High corrosion and acid resistant materials
Clean line profile design with full machined end covers
Technical dataMedium:Compressed air, filtered, lubricated or non-lubricatedOperation:Double acting, with adjustable cushioningStandard:ISO 6431, VDMA 24562, NFE 49-003-1Operating pressure:1 to 10 barOperating temperature:-40°C to +80°C max. Cylinder diameters:32, 40, 50, 63, 80, 100 and 125 mmStrokes:Standard, see page 2Non-standard strokes (10 to 3000 mm) available
MaterialsProfile barrel: clear anodised aluminiumEnd covers: black anodiseed aluminiumPiston rod: hart chromium plated stainless steel X10 Cr Ni S 18 9 (AISI 303, 1.4305)Piston rod nut: X10 Cr Ni S 18 9 (AISI 303, 1.4305)Cover screws: X10 Cr Ni S 18 9 (AISI 303, 1.4305)Tie rods: X10CrN, S189Piston and piston rod seals: polyurethaneO-rings: nitrile rubber
Mountings
See page 3Ordering examples
See page 4 and 5
SwitchesOn request
3/04Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document.
N/UK 1.5.149.02
LPDA/182000, LPDA/182000/M
Ø 25 50 80 100 125 160 200 250 320 400 500
Standard strokes Strokes (mm)
32 ¬ ¬ ¬ ¬ ¬ ¬ ¬ ¬ ¬ ¬ ¬40 ¬ ¬ ¬ ¬ ¬ ¬ ¬ ¬ ¬ ¬ ¬50 ¬ ¬ ¬ ¬ ¬ ¬ ¬ ¬ ¬ ¬ ¬63 ¬ ¬ ¬ ¬ ¬ ¬ ¬ ¬ ¬ ¬ ¬80 ¬ ¬ ¬ ¬ ¬ ¬ ¬ ¬ ¬ ¬ ¬100 ¬ ¬ ¬ ¬ ¬ ¬ ¬ ¬ ¬ ¬ ¬125 ¬ ¬ ¬ ¬ ¬ ¬ ¬ ¬ ¬ ¬ ¬
Symbol
Cylinder variantsSymbol
Non-magnetic piston Magnetic pistonPageDescriptionModel Model
WarningThese products are intended for use in industrial compressed airsystems only. Do not use these products where pressures andtemperatures can exceed those listed under ‘Technical Data’.
Before using these products with fluids other than those specified,for non-industrial applications, life-support systems, or otherapplications not within published specifications, consultNORGREN.Through misuse, age, or malfunction, components used in fluidpower systems can fail in various modes.
The system designer is warned to consider the failure modes of allcomponent parts used in fluid power systems and to provideadequate safeguards to prevent personal injury or damage toequipment in the event of such failure.
System designers must provide a warning to end users in thesystem instructional manual if protection against a failuremode cannot be adequately providedSystem designers and end users are cautioned to review specificwarnings found in instruction sheets packed and shipped with theseproducts.
LPDA/182000 LPDA/182000/M Standard cylinders 6
LPDA/182000/JM Standard with double ended piston rod 7
LPDA/182000/MT Four position cylinders 7
3/04 Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document.
N/UK 1.5.149.03
LPDA/182000, LPDA/182000/M
Options selector LPDA/182˙˙˙/˙˙/˙˙˙˙
Stroke10 ... 3000, non-magnetic piston25 ... 3000 magnetic piston
Cylinder diameters Substitute32 03240 04050 05063 06380 080100 100125 125
Variants (with switches) SubstituteStandard MDouble ended piston rod JMFour position MTExtended piston rod MULPDA/182***/MU/****/***
Extension (mm)
For combinations of cylinder variantsconsult our »Technical Service«
Ordering ExamplesCylindersTo order a standard 80 mm bore magnetic piston cylinder with a 50 mm strokequote: LPDA/182080/M/50
MountingsTo order a front flange mounting style G for 80 mm bore,stainless steel materialquote: KQA/8080/22
3/04Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document.
N/UK 1.5.149.04
LPDA/182000, LPDA/182000/M
32 QA/8032/27 M/P19931 M/P19493 QM/8025/32 QA/8032/33 M/P4031040 QA/8040/27 M/P19932 M/P19494 QM/8040/32 QA/8040/33 M/P4031150 QA/8050/27 M/P19933 M/P19495 QM/8050/32 QA/8050/33 M/P4031263 QA/8063/27 M/P19934 M/P19496 QM/8050/32 QA/8063/33 M/P4031380 QA/8080/27 M/P19935 M/P19497 QM/8080/32 QA/8080/33 M/P40314100 QA/8100/27 M/P19936 M/P19498 QM/8080/32 QA/8100/33 M/P40315125 QM/8125/27 M/P19937 M/P19499 QM/8125/32 QM/8125/33 M/P71355
MountingsStyle A Style AK Style B/G Style C Style D Style D2 Style F
32 QM/8032/35 QM/8025/38 QA/8032/22 QA/8032/21 QA/8032/23 QA/8032/42 QM/8025/2540 QM/8032/35 QM/8040/38 QA/8040/22 QA/8040/21 QA/8040/23 QA/8040/42 QM/8040/2550 QM/8050/35 QM/8050/38 QA/8050/22 QA/8050/21 QA/8050/23 QA/8050/42 QM/8050/2563 QM/8050/35 QM/8050/38 QA/8063/22 QA/8063/21 QA/8063/23 QA/8063/42 QM/8050/2580 QM/8080/35 QM/8080/38 QA/8080/22 QA/8080/21 QA/8080/23 QA/8080/42 QM/8080/25100 QM/8080/35 QM/8080/38 QA/8100/22 QA/8100/21 QA/8100/23 QA/8100/42 QM/8080/25125 QM/8125/35 QM/8125/38 QM/8125/22 QM/8125/21 QM/8125/23 QM/8125/42 QM/8125/25
32 – – PVQA/8032/22 – PVQA/8032/23 – PVQM/8032/2540 – – PVQA/8040/22 – PVQA/8040/23 – PVQM/8040/2550 – – PVQA/8050/22 – PVQA/8050/23 – PVQM/8050/2563 – – PVQA/8063/22 – PVQA/8063/23 – PVQM/8050/2580 – – PVQA/8080/22 – PVQA/8080/23 – PVQM/8080/25100 – – PVQA/8100/22 – PVQA/8100/23 – PVQM/8080/25125 – – – – – – –
32 – – KQA/8032/22 KQA/8032/21 KQA/8032/23 – KQM/55433/2540 – – KQA/8040/22 KQA/8040/21 KQA/8040/23 – KQM/55441/2550 – – KQA/8050/22 KQA/8050/21 KQA/8050/23 – KQM/55451/2563 – – KQA/8063/22 KQA/8063/21 KQA/8063/23 – KQM/55451/2580 – – KQA/8080/22 KQA/8080/21 KQA/8080/23 – KQA/8080/25100 – – KQA/8100/22 KQA/8100/21 KQA/8100/23 – KQA/8080/25125 – – KQA/8125/22 KQA/8125/21 KQA/8125/23 – KQA/8125/25
Page 8 Page 8 Page 8 Page 8 Page 8 Page 8 Page 9Ø
Ø
Style R Style SS Style SW Style UF Style UR
Page 9 Page 10 Page 10 Page 9 Page 9
Style US
Page 10
Stainless steel
Corrision protected
Standard
32 PVQA/8032/27 M/P40465 M/P40459 PVQM/8032/32 PVQA/8032/33 –40 PVQA/8040/27 M/P40466 M/P40460 PVQM/8040/32 PVQA/8040/33 –50 PVQA/8050/27 M/P40467 M/P40461 PVQM/8050/32 PVQA/8050/33 –63 PVQA/8063/27 M/P40468 M/P40462 PVQM/8050/32 PVQA/8063/33 –80 PVQA/8080/27 M/P40469 M/P40463 PVQM/8080/32 PVQA/8080/33 –100 PVQA/8100/27 M/P40470 M/P40464 PVQM/8080/32 PVQA/8100/33 –125 – – – – – –
32 KQA/8032/27 - M/P72288 - KQA/8032/33 -40 KQA/8040/27 - M/P72289 - KQA/8040/33 -50 KQA/8050/27 - M/P72290 - KQA/8050/33 -63 KQA/8063/27 - M/P72291 - KQA/8063/33 -80 KQA/8080/27 - M/P72292 - KQA/8080/33 -100 KQA/8100/27 - M/P72293 - KQA/8100/33 -125 - - M/P72432 - - -
Stainless steel
With surface treatment
Standard
Alternative versions
Alternative versions
Mountings
3/04 Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document.
N/UK 1.5.149.05
LPDA/182000, LPDA/182000/M
1
15
16
17
18
20
10
2
3
4
5
7
6
8
Materials and surface treatment of mountings and accessoriesStandard cylinders
Recommended mounting rangeStandardClear anodised aluminium.Galvanized steel (ø 32 ... 63 mm). Painted steel (ø 80 & 125 mm)Diecast aluminium
Galvanized aluminium.Inner ring: steelOuter ring: brass
Diecast aluminium. Bolt: galvanized steel (martensitic).Circlip: galvanized steel
Diecast aluminium
Painted cast iron. Bolt: stainless steel (martensitic). Circlip: galvanized steelGalvanized aluminium. Inner ring: steelOuter ring: brass—Galvanized steelGalvanized steel.Bolt: galvanized steel.Circlip: Galvanized steel.Painted cast ironGalvanized steel. Inner ring: steel.Outer ring: brassGalvanized steelBody: PBTand nickel plated brass. Grab ring: stainless steel. Release sleeve: POM. Catalogue page 9.1.001
Position Style1 B, G2 C
3 R
4 UR
5 D
6 US
7 SW
8 D2
9 Cover screws10 A15 F
16 SS17 UF
18 AK20 Fittings
Corrosion protectedClear anodised aluminium. Screws: A2 —
Black corrosion protected diecast aluminium. Certified for the food industrie. Screws: A2Black corrosion protected diecast aluminium. Certified for the food industry. Inner ring: stainless Steel (austenitic).Outer ring: nickel plated hardened steel.Black corrosion protected diecast aluminium. Certified for the food industry.Bolt: X 10 Cr Ni S 18 9 (1.4305, AISI 303).Circlip: Stainless steel (martensitic). Screws: A2Black corrosion protected diecast aluminium. Certified for the food industry.—
—
——Nickel plated steel. Circlip: X 10 Cr Ni S 18 9 (1.4305, AISI 303).Bolt: X 10 Cr Ni S 18 9 (1.4305, AISI 303).Cast iron nickel plated.Nickel plated steel. Inner ring: stainless steel (austenitic). Outer ring: nickel plated hardened steel.—
Stainless steelX 5 Cr Ni 18 10 (1.4301; AISI 304). Screws: A2X 5 Cr Ni 18 10 (1.4301; AISI 304). Screws: A2
X 5 Cr Ni 18 10 (1.4301; AISI 304). Screws: A2Bearing: POMX 5 Cr Ni 18 10 (1.4301; AISI 304). Screws: A2
X 5 Cr Ni 18 10 (1.4301; AISI 304). Screws: A2.Bolt: X 10 Cr Ni S 18 9 (1.4305; AISI 303)
G-X 6 Cr Ni 18 9 (1.4308; AISI 304)
—
—
X 10 Cr Ni S 18 9 (1.4305, AISI 303)—X 10 Cr Ni S 18 9 (1.4305; AISI 303).Bolt: X 10 Cr Ni S 18 9 (1.4305; AISI 303).Eyebolt: X 10 Cr Ni S 18 9 (1.4305; AISI 303).——
—Body and grab ring: stainless steel. Release sleeve: acetal.O-Ring: viton Catalogue page 9.3.001
Alternative mounting range
Stroke
Cushion screw
Size for Ø 80 to 125 mm
3/04Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document.
N/UK 1.5.149.06
LPDA/182000, LPDA/182000/M
Ø
Typ Ø AM AP AP2 Ø B e11 Ø BA e11 BG BH …E EE G KK KV KW L2LPDA/182032 32 22 3,5 7,5 30 30 18 6 47 G1/8 27,5 M10 x 1,25 17 5 20LPDA/182040 40 24 4,5 8,5 35 35 18 6 53 G1/4 32 M12 x 1,25 19 6 22LPDA/182050 50 32 6 11,5 40 40 18 8 65 G1/4 31 M16 x 1,5 24 8 27LPDA/182063 63 32 10 14,5 45 45 17,5 8 75 G3/8 33 M16 x 1,5 24 8 29LPDA/182080 80 40 8,5 19,5 45 45 21,5 19 95 G3/8 33 M20 x 1,5 30 10 33LPDA/182100 100 40 9 22 55 55 21,5 19 115 G1/2 37 M20 x 1,5 30 10 36LPDA/182125 125 54 10 – 60 60 30 24 140 G1/2 46 M27 x 2 41 13,5 45Typ Ø L8 L9 L12 Ø MMh9 PL …R RT SW VA VD WH kg at 0 mm kg per 25 mmLPDA/182032 32 94 4 6 12 13 32,5 M6 10 3 6 26 0,51 0,06LPDA/182040 40 105 4 6,5 16 15 38 M6 13 3,5 6 30 0,80 0,08LPDA/182050 50 106 5 8 20 18,5 46,5 M8 17 3,5 6 37 1,33 0,12LPDA/182063 63 121 5 8 20 19 56,5 M8 17 4 6 37 1,80 0,13LPDA/182080 80 128 5,5 10 25 19 72 M10 22 4 6 46 3,25 0,20LPDA/182100 100 138 5,5 10 25 18 89 M10 22 4 6 51 4,81 0,23LPDA/182125 125 160 – 13 32 22,5 110 M12 27 6 15,5 65 8,00 0,33
LPDA/182000/...
32 482 414 13 8,5 0,056 0,04840 754 633 17 16 0,088 0,07450 1178 990 22 33 0,137 0,11463 1870 1680 22 58 0,218 0,19580 3016 2722 27 116 0,35 0,32100 4710 4416 34 242 0,55 0,51125 7363 6882 41 451 0,86 0,79
Theoretical Forces ¬ Cushioning ¬ Air Consumption
2
1
#
Cushion length(mm)
Initial cushion volume(cm3)
Air consumption (l/cm stroke) at 6 barOutstroke InstrokeOutstroke Instroke
Theoretical forces (N) at 6 bar
E
R
BH
L8 + #
GGL2
VD PL
EEL12
KW
AM
KK
ø B
e 1
1
L 9
BG
RT
ø B
A e
11
BG
RT
BH
A
B
VA
MM
h 9
WH
AP
A - B
EE
PL
KV SW
1 1
2
3/04 Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document.
N/UK 1.5.149.07
LPDA/182000, LPDA/182000/M
L 10 + # 1 + # 2
L11L 8 + # 1 L 8 + # 2
Typ Ø L8 ZM at 0 mm at 25 mmLPDA/182032/JM 32 94 146 0,67 0,09LPDA/182040/JM 40 105 165 1,09 0,13LPDA/182050/JM 50 106 180 1,77 0,19LPDA/182063/JM 63 121 195 2,39 0,21LPDA/182080/JM 80 128 220 3,96 0,33LPDA/182100/JM 100 138 240 5,82 0,36LPDA/182125/JM 125 160 290
LPDA/182000/JM
ZM + 2 x #
L 8 + #
Typ Ø L8 L10 L11 at 0 mm at 25 mmLPDA/182032/MT 32 94 247 7LPDA/182040/MT 40 105 278 8LPDA/182050/MT 50 106 294 8LPDA/182063/MT 63 121 325 9LPDA/182080/MT 80 128 357 9LPDA/182100/MT 100 138 387 9LPDA/182125/MT 125 160 462 12
LPDA/182000/MT
Missing dimensions see page 6
Missing dimensions see page 6
# Stroke
#2
#1 Stroke for the first cylinder
Stroke for the second cylinder
at per
3/04Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document.
N/UK 1.5.149.08
LPDA/182000, LPDA/182000/M
Front or rear stud A Piston rod swivel AK
BBD
D TG
TG
Rear flage B Front flage G Foot C
B 1
L 2
L
F
KK
4°4°
KK
3 2 4 1
UF
TF
FB
RE
MF
AOAUA
T AH
ø AB
TR
E
Stainless steel
(Corresponds to DIN ISO 6431, Style MX1)
(Corresponds to DIN ISO 6431 and VDMA 24562 Part 2, Style MS1)(Corresponds to DIN ISO 6431 and VDMA 24562 Part 2,Style MF1 and MF2)
PVQA/8032/22 32 50 7 10 32 64 80 0,25PVQA/8040/22 40 55 9 10 36 72 90 0,35PVQA/8050/22 50 65 9 12 45 90 110 0,70PVQA/8063/22 63 75 9 12 50 100 125 0,80PVQA/8080/22 80 100 12 16 63 126 154 1,35PVQA/8100/22 100 120 14 16 75 150 186 2,20KQA/8125/22 125 140 16 20 90 180 224 1,70
Typ (B - G) Ø E Ø FB MF R TF UF kg Typ (C) Ø Ø AB AH AO AT AU E TR kg1)
KQA/8032/21 32 7 32 11 4 24 48 32 0,16KQA/8040/21 40 9 36 12 5( 28 53 36 0,19KQA/8050/21 50 9 45 13( 5 32 64 45 0,32KQA/8063/21 63 9 50 13 5 32 74 50 0,41KQA/8080/21 80 12 63 19 6 41 98 63 0,83KQA/8100/21 100 14 71 19 6 41 115 75 0,98KQA/8125/21 125 16 90 25 7 45 140 90 2,40
QA/8032/21 32 7 32 8 4 24 48 32 0,16QA/8040/21 40 9 36 9 4 28 53 36 0,19QA/8050/21 50 9 45 10 5 32 64 45 0,32QA/8063/21 63 9 50 12 5 32 74 50 0,41QA/8080/21 80 12 63 19 5 41 98 63 0,83QA/8100/21 100 14 71 19 5 41 115 75 0,98QM/8125/21 125 16 90 20 9 45 140 90 2,40
QM/8032/35 32/40 17 M6 32,5/38 0,02QM/8050/35 50/63 23 M8 46,5/56,5 0,05QM/8080/35 80/100 28 M10 72/89 0,08QM/8125/25 125 34 M12 110 0,14
Typ (A) Ø BB DD TG kg Typ (AK) Ø Gewinde KK B1 F L L2 1 2 3 4 kgQM/8025/38 32 M10x1,25 5 26 73 20 19 12 17 30 0,2QM/8040/38 40 M12x1,25 6 26 77 24 19 12 19 30 0,2QM/8050/38 50/63 M16x1,5 8 34 106 32 30 19 24 42 0,65QM/8080/38 80/100 M20x1,5 10 42 122 40 30 19 30 42 0,72QM/8125/38 125 M27x2 13,5 40 147 54 40 24 41 55 1,70
Standard
3/04 Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document.
N/UK 1.5.149.09
LPDA/182000, LPDA/182000/M
Piston rod clevis F
CE
LE
CL
ER
KK
ø C
K h
11
RK
CL
CM
Rear eye R
EW
FL
L
CD
H 9
MR
PVQM/8032/25 32 M10x1,25 40 10 20 10 16 20 28 0,09PVQM/8040/25 40 M12x1,25 48 12 24 12 19 24 32 0,13PVQM/8050/25 50/63 M16x1,5 64 16 32 16 25 32 41,5 0,33PVQM/8080/25 80/100 M20x1,5 80 20 40 20 32 40 50 0,67PVQM/8125/25 125 M27x2 110 30 55 30 45 54 62 1,35
Typ (F) Ø Thread KK CE Ø CK h11 CL CM ER LE RK kgPVQA/8032/27 32 10 25,8 22 13 9 0,09PVQA/8040/27 40 12 27,8 25 16 12 0,11PVQA/8050/27 50 12 31,7 27 17 12 0,17PVQA/8063/27 63 16 39,7 32 22 15 0,24PVQA/8080/27 80 16 49,7 36 22 15 0,37PVQA/8100/27 100 20 59,7 41 27 20 0,59QM/8125/27 125 25 69,7 50 33 25 3,20
Typ (R) Ø Ø CDH9 EW FL L MR kg
PVQA/8032/33 32 10 14 16 22 14,5 13° 0,15PVQA/8040/33 40 12 16 19 25 18 13° 0,25PVQA/8050/33 50 16 21 21 27 19 13° 0,4PVQA/8063/33 63 16 21 24 32 24 15° 0,55PVQA/8080/33 80 20 25 28 36 24 15° 0,9PVQA/8100/33 100 20 25 30 41 29 15° 1,5QM/8125/33 125 30 37 40 50 36 15° 2,7
Typ (UR) Ø Ø CNH7 EN ER FL R Z kg
EN
ZZ
FL
ER
R
CN
H 7
Universal rear eye URUniversal piston rod eye UF
EN -0,1
ZZ
CE
CN H 7
LE AXER
KK
PVQM/8025/32 32 M10x1,25 20 43 10 14 14 15 13° 0,09PVQM/8040/32 40 M12x1,25 22 50 12 16 16 17 13° 0,13PVQM/8050/32 50/63 M16x1,5 28 64 16 21 21 22 15° 0,33PVQM/8080/32 80/100 M20x1,5 33 77 20 25 25 26 15° 0,67QM/8125/32 125 M27x2 51 110 30 37 35 36 15° 1,35
Typ (UF) Ø Thread KK AX CE Ø CNH7 EN-0,1 ER LE Z kg
(Corresponds to DIN ISO 8140) (Corresponds to DIN ISO 6431 and VDMA 24562 Part 2, Style MP4)
(Corresponds to DIN ISO 8139) (Corresponds to VDMA 24562 Part 2)
Rear clevis D(Corresponds to DIN ISO 6431 and VDMA 24562 Part 2, Style MP2)
LH
CB H 14
UB
L
FL
MR
EK
f 8
FL
R1
R2
B3
EK
1 h
9
B2
B1 H 14
Rear clevis D2(Corresponds to VDMA 24562 Part 2)
PVQA/8032/23 32 26 10 22 13 52 9 45 0,11PVQA/8032/23 40 28 12 25 16 60 12 52 0,16PVQA/8050/23 50 32 12 27 17 68 12 60 0,22PVQA/8063/23 63 40 16 32 22 79 15 70 0,34PVQA/8080/23 80 50 16 36 22 99 15 90 0,54PVQA/8100/23 100 60 20 41 27 119 20 110 0,90KQA/8125/23 125 70 25 50 31 140 25 130 2,70
Typ (D) Ø CBH14 Ø EKf8 FL L LH MR UB kg Typ (D2) Ø B1H14 B2 B3 Ø EKh9FL R1 R2 kgQA/8032/42 32 14 34 3,3 10 22 11 17 0,20QA/8040/42 40 16 40 4,3 12 25 12 20 0,23QA/8050/42 50 21 45 4,3 16 27 14,5 22 0,36QA/8063/42 63 21 51 4,3 16 32 18 25 0,55QA/8080/42 80 25 65 4,3 20 36 22 30 0,90QA/8100/42 100 25 75 6,3 20 41 22 32 1,45QM/8125/42 125 37 97 6,3 30 50 30 42 2,70
Stainless steel, weight on request
Dimensions of mountings with different materials or surface treatment are the same, if not special information notes are given.
3/04Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document.
N/UK 1.5.149.010
LPDA/182000, LPDA/182000/M
EM
K 1
K 2
ø S
ø D
L 1
ø C
N G
7
G 2
G 3
G 1
R
CA
H 2
K 1
K 2
ø S
ø D
L 1
G 2
G 3
ER
CH
H 2
G 1EU
ZZ
ø C
N H
7
EN -0,1
EM
K 1
K 2
ø S
ø D
L 1
ø C
K H
9
G 2
G 3
G 1
R
CA
H 2
Typ (US) Ø CH Ø CNH7 Ø D EN-0,1 ER EU G1 G2 G3 H2 K1 K2 L1 Ø S Z kgM/P40310 32 32 10 11 14 16 10,5 21 18 31 8 38 51 1,6 6,6 13° 0,19M/P40311 40 36 12 11 16 19 12 24 22 35 10 41 54 1,6 6,6 13° 0,24M/P40312 50 45 16 15 21 21 15 33 30 45 12 50 65 1,6 9 13° 0,46M/P40313 63 50 16 15 21 24 15 37 35 50 12 52 67 1,6 9 15° 0,59M/P40314 80 63 20 18 25 28 18 47 40 60 14 66 86 2,5 11 15° 1,03M/P40315 100 71 20 18 25 30 18 55 50 70 15 76 96 2,5 11 15° 1,40M/P71355 125 90 30 20 371 40 25 70 60 90 20 94 124 - 14 15° 3,10Typ (SS) Ø CA Ø CNG7 Ø D H2 EM G1 G2 G3 K1 K2 L1 R Ø S kgM/P40465 32 32 10 11 8 10 21 18 31 38 51 1,6 10 6,6 0,15M/P40466 40 36 12 11 10 12 24 22 35 41 54 1,6 11 6,6 0,20M/P40467 50 45 10 15 12 16 33 30 45 50 65 1,6 13 9 0,48M/P40468 63 50 16 15 12 16 37 35 50 52 67 1,6 15 9 0,50M/P40469 80 63 20 18 14 20 47 40 60 66 86 2,5 15 11 0,75M/P40470 100 71 20 18 15 20 55 50 70 76 96 2,5 19 11 1,20M/P19937 125 90 25 20 20 30 70 60 90 94 124 - 22 14 2,50
Typ (SW) Ø CA Ø CKH9 Ø D H2 EM G1 G2 G3 K1 K2 L1 R Ø S kgM/P40459 32 32 10 11 8 26 21 18 31 38 51 1,6 10 6,6 0,05M/P40460 40 36 12 11 10 28 24 22 35 41 54 1,6 11 6,6 0,07M/P40461 50 45 12 15 12 32 33 30 45 50 65 1,6 13 9 0,14M/P40462 63 50 16 15 12 40 37 35 50 52 67 1,6 15 9 0,18M/P40463 80 63 16 18 14 50 47 40 60 66 86 2,5 15 11 0,28M/P40464 100 71 20 18 15 60 55 50 70 76 96 2,5 19 11 0,42M/P19499 125 90 25 20 20 70 70 60 90 94 124 - 22 14 2,70*
Wide hinge SWNarrow hinge SSSwivel hinge US(Corresponds to VDMA 24562 Part 2) (Corresponds to VDMA 24562 Part 2)
21 6 11 10 526
Spares for standard version
Please quote the cylinder type number when ordering spares kits and piston rods.
ø32 LPDA/182032... LPDQA/182032/00 2 DM/P30179/*40 LPDA/182040... LPDQA/182040/00 DM/P30180/*50 LPDA/182050... LPDQA/182050/00 DM/P30181/*63 LPDA/182063... LPDQA/182063/00 DM/P30182/*80 LPDA/182080... LPDQA/182080/00 DM/P30183/*100 LPDA/182100... LPDQA/182100/00 DM/P30184/*125 LPDA/182125... LPDQA/182125/00 DM/P30988/*
2 Piston rod seal 15 Cushion seal 26 ‘O’ ring 210 Piston seal 211 Wear ring 126 ‘O’-ring 1
Model Spares kit ComprisingDescription Quantity Piston rod
* Insert stroke length
Item
Dimensions of mountings with different materials or surface treatment are the same, if not special information notes are given.
4/04 N/UK 5.11.005.01Our policy is one of continued research and development. We therefore reserve the rightto amend, without notice, the specifications given in this document.
18D-LTPneumatic pressure switches
For extreme temperatures -40°C to +85°CRelative pressure - 1 to 16 bar
Technical dataMedium:Neutral, gaseous and liquid fluids, non-combustibleOperation:DiaphragmPort sizes:G1/4 (BSP), 1/4 NPT (on request), FlangeOperating pressure:-1 to 16 barElectrical connection:Acc. to DIN EN 17031-801 (DIN 43650 A) orAcc. to IEC 947-5-2 (M 12 x 1)Fluid temperature:Reproducibility: -25 to +85°CReliability: -40 to +80°CAmbient temperature:Reproducibility: -25 to + 85°CReliability: -40 to +80°CTemperature at switching element:+80°CConsult our Technical Service for use below +2°C.
Mounting:OptionalViscosity:Up to 1000 mm2/sRepeatability:±3%, for vacuum ± 4% of final valueSwitching element:Microswitch (gold plated contacts)Degree of protection:IP65 for conn. DIN 43650IP67 for conn. M 12 x 1
MaterialsSensor: aluminium anodized, silicon (VMQ)
Wide temperature range: -40°C to + 5°C
High number of switching cycles
For indoor and outdoor applications
Microswitch approved by UL and CSA
Microswitch with gold plated contacts
Ordering informationSee page 2
Switching function:Microswitch SPDTTerminals 1 - 3:Contacts close onrising pressure.Terminals 1 - 2:Contacts open onrising pressure.
Switching functionM12 x 1:Microswitch SPDTTerminals 1 - 4:Contacts close onrising pressure.Terminals 1 - 2:Contacts open onrising pressure.
2 3
1
p
2 4
1
p
4/04N/UK 5.11.005.02
18D-LT
Our policy is one of continued research and development. We therefore reserve the rightto amend, without notice, the specifications given in this document.
18D-LT options with electrical connection DIN EN 17031-801 (DIN 43650 A)*
18D-LT options with electrical connection M 12 x 1 (Max. allowable voltage 30 V)*
** Reference pressure is atmospheric air pressure# Short-term pressure peaks are not allowed to exceed this limit value during operation.Operative utilization of the limit value is not permitted.The limit value corresponds to the maximumpressure## Typical values‡ Switching function reversed (Signal with rising vacuum).Key to materials: Al = AluminiumNBR = PerbunanVMQ = Silicon
Options selector
088˙˙5˙
Eletrical connection SubstituteDIN EN 175301-803 (DIN 43650, form A) 7M 12 x 1 8
Variants SubstituteThread 0Flange 1
Switching pressure range Substitute-1 ... 0 10,2 ... 2 20,5 ... 8 31 ... 10 41 ... 16 6
Ordering informationTo order, quote part number from table overleaf, e.g. G 1/4 ported switch with a pressure range of 0,5 to 8 barquote: 00888800335577
* Plug supplied
0880157 -1 ... 0 0,2 0,4 26 100 AL, anodized EPDM, VMQ Female G1/4 0,2 020880257 0,2 ... 2 0,25 0,45 26 100 AL, anodized EPDM, VMQ Female G1/4 0,2 020880357 0,5 ... 8 0,45 0,9 26 100 AL, anodized EPDM, VMQ Female G1/4 0,2 010880457 1 - 10 0,5 1,1 26 100 AL, anodized EPDM, VMQ Female G1/4 0,2 010880657 1 - 16 0,5 1,1 26 100 AL, anodized EPDM, VMQ Female G1/4 0,2 010881157 -1 ... 0 0,2 0,4 26 100 AL, anodized EPDM, VMQ, NBR – Flange 0,2 030881257 0,2 ... 2 0,25 0,45 26 100 AL, anodized EPDM, VMQ, NBR – Flange 0,2 030881357 0,5 ... 8 0,45 0,9 26 100 AL, anodized EPDM, VMQ, NBR – Flange 0,2 030881457 1 ... 10 0,5 1,1 26 100 AL, anodized EPDM, VMQ, NBR – Flange 0,2 030881657 1 ... 16 0,5 1,1 26 100 AL, anodized EPDM, VMQ, NBR – Flange 0,2 03
Model Pressure range(bar)**
Pressure difference (bar)##lower range upper range
Maximumover-pressure(bar)#
Switching cycles(1/min)
Pressure sensor material Fluid connection kg Drawing no.Housing Seal Type Size
0880158 -1 ... 0 0,2 0,4 26 100 AL, anodized EPDM, VMQ Female G 1/4 0,2 020880258 0,2 ... 2 0,25 0,45 26 100 AL, anodized EPDM, VMQ Female G 1/4 0,2 020880358 0,5 ... 8 0,45 0,9 26 100 AL, anodized EPDM, VMQ Female G 1/4 0,2 010880458 1 ... 10 0,5 1,1 26 100 AL, anodized EPDM, VMQ Female G 1/4 0,2 010880658 1 ... 16 0,5 1,1 26 100 AL, anodized EPDM, VMQ Female G 1/4 0,2 010881158 -1 ... 0 0,2 0,4 26 100 AL, anodized EPDM, VMQ, NBR – Flange 0,2 030881258 0,2 ... 2 0,25 0,45 26 100 AL, anodized EPDM, VMQ, NBR – Flange 0,2 030881358 0,5 ... 8 0,45 0,9 26 100 AL, anodized EPDM, VMQ, NBR – Flange 0,2 030881458 1 ... 10 0,5 1,1 26 100 AL, anodized EPDM, VMQ, NBR – Flange 0,2 030881658 1 ... 16 0,5 1,1 26 100 AL, anodized EPDM, VMQ, NBR – Flange 0,2 03
‡
‡
Model Pressure range(bar)**
Pressure difference (bar)##lower range upper range
Maximumover-pressure(bar)#
Switching cycles(1/min)
Pressure sensor material Fluid connection kg Drawing no.Housing Seal Type Size
* Plug not supplied
4/04N/UK 5.11.005.03
18D-LT
Our policy is one of continued research and development. We therefore reserve the rightto amend, without notice, the specifications given in this document.
Accessories
0574767 (brass) 0574773 (brass) 0554737 0523058 (2 m cable) 0523056 (without cable) 0523057 (2 m cable) 0523055 (without cable)0550083 (stainless steel) 0553258 (stainless steel) 0523053 (5 m cable) 0523052 (5 m cable)
Pressure port reducingnipple
Snubber Connector M 12x190°4 pins
Connector M 12x1Straight4 pins
Cover (withadjustment screw)
Making and/or breaking capacityChange-over switch with gold-plated contacts
Reference number of switchings: 30/min, reference temperature: +30°C.Spark quenching with diode with d.c. and inductive load: Imax = 1,5 x Imax of table Imin = 1 [mA]Creepage and air paths correspond to insulation group B according to VDE reg. 0110 (except contact clearance of microswitch).* Gold-plating not required as it would decay. Maximum permitted in-rush current (approximately 30 ms) a.c. make = max. 15A.**Gold-plating required (will not decay).# Lower value of critical voltage guarantees sufficient contact safety. Lower voltages permissible under favourable conditions.
LLooaadd lleevveell TTyyppee ooff TTyyppee ooff llooaadd UUmmiinn MMaaxxiimmuumm ppeerrmmaanneenntt ccuurrrreenntt IImmaaxx [[AA]] aatt UU [[VV]] CCoonnttaacctt lliiffeeccuurrrreenntt [[VV]] 3300 4488 6600 112255 225500
Standard * a.c. Resistive load 12 5 5 5 5 5 Switching (e.g. contractors, cyclessolenoids) a.c. Inductive load, 12 3 3 3 3 3 ∫107
cos Ÿ 0,7d.c. Resistive load 12 5 1,2 0,8 0,4 –d.c. Inductive load, 12 3 0,5 0,35 0,05 –
L/R Ÿ 10 msLow ** a.c. Resistive load 5# 0,34 0,2 0,17 0,08 0,04 Switching(e.g. electronic cyclescircuits) d.c. Inductive load, 5# 0,1 0,01 – – – ∫107
L/R Ÿ 10 ms
(M12x1)
Proposal for spark extinction with direct voltage1. Diode D parallel to the inductive load.Observe correct polarity with connection (positive pole atcathode).
Specificatons for erasing diode:Nominal voltage of the diode UD ∫ 1,4 x Us.Nominal current of the diode IN ∫ Iload.
Select fast switching diodes (blocking recovery time trr√ 200 [ms]).
2. RC element parallel to the load (or parallel to theswitching contact).Suitable for direct voltage and alternating voltage.
Ratings:R in [∆] Ÿ 0,2 x Rload in [∆]C in [µF] Ÿ Rload in [A]
+ (AC)
- (AC)
p
D R
C
R Last
I Last
V S
4/04N/UK 5.11.005.04
18D-LT
Our policy is one of continued research and development. We therefore reserve the rightto amend, without notice, the specifications given in this document.
G 1/4 Flange
WarningThese products are intended for use in industrial compressed airsystems only. Do not use these products where pressures andtemperatures can exceed those listed under ‘Technical Data’.
Before using these products with fluids other than those specified, fornon-industrial applications, life-support systems, or other applicationsnot within published specifications, consult NORGREN.
Through misuse, age, or malfunction, components used in fluid powersystems can fail in various modes.
The system designer is warned to consider the failure modes of allcomponent parts used in fluid power systems and to provide adequatesafeguards to prevent personal injury or damage to equipment in theevent of such failure.
System designers must provide a warning to end users in thesystem instructional manual if protection against a failure modecannot be adequately provided.
System designers and end users are cautioned to review specificwarnings found in instruction sheets packed and shipped with theseproducts.
27
20
30
30
15
5,3 72
9,5
2
27
20
30
30
15
5,3 72
15,5
2
30
1,2
721
20
30
15
5,3 3
G 1/4 A
G 1/2 A
31
43
22
❑ 30 7
1,5
G 1/4 A
34
46
G 1/4
Ø21,5
22
2 1/4 NPT on request
M12
x 1
20
10
30
21,2
9,2
30
3 ‘O’ ring 5 x 1,5
2 1/4 NPT on request
Adjustable switch pointAfter releasing the locking screwClockwise rotation = encreasing switch pointAnti-clockwise rotation = decreasing the switch point
+-
4
5
5
4 Switch point screw
Locking screw
1
G 1/4
2
3
Pressure port reducing nippleMaterials: brassModel: 0574767Materials: stainless steel (1.4301)Model: 0550083
SnubberMaterials: brassModel: 0574773Materials: stainless steel (1.4301)Model: 0553258
Cover (withadjustment screw)Model: 0554737
Electrical connectionDIN 43650, form A
Electrical connectionM12x1
Actuators
www.norgren.com/info/en184184
High corrosion and acid resistantmaterialsFrictionless operationNo maintenance or lubricationIdeal for short stroke, high-forceapplicationsHigh isolation level for vibratingmachinesVery easy to install – no alignmentproblems
Technical dataMedium:Compressed air, non-lubricatedOperation:Single acting Operating pressure:8 bar max.Operating temperature:-40°C to +70°C for KM/31000(Standard)-25°C to +90°C for TKM/31000 (Butyl)-20°C to +115°C for EKM/31000(Epichlore)Consult our Technical Service for use below +2°C
Strokes:80 to 380 mm max., depending ondiameter and number of convolutions.
MaterialsEnd plates, fixing studs and centralring: stainless steel 1.4301Rubber part: fabric reinforced NR-,SBR- and BR compound rubber(KM/31000), fabric reinforced butyl(TKM/31000), fabric reinforcedEpichlore (EKM/31000)Important note: The design of these air bellows allows anoperation at an angle of 5° to 25°. The top and bottomplate can be out of alignment, depending on the height ofthe air bellow and the number of convolutions. To avoiddamage, mechanical stops at both end positions have tobe used. To return air bellows to their minimum height anexternal return force must be used. The thrust dependsdirectly on the height of the air bellow: when heightincreases, the thrust decreases. As the outside diametervaries in operation there must be enough clearancearound the air bellow.
Serviceable air bellowsStainless steelKM/31000Single actingØ 8 to 14Ë"
Options selector˙KM / 3 1 ˙ ˙ ˙
No. of convolutions Substitute1 12 23 3
Nominal diameter (inch) Substitute8 0810 1012 1214Ë 14
Air bellow materials SubstituteHigh temperature (Butyl) TExtreme temperature (Epichlore) E
Note: disregard option positions not used.
KM/31081 8 x 1 80 G1/2 KM/31082 8 x 2 175 G1/2 KM/31101 10 x 1 100 G1/2 KM/31102 10 x 2 225 G1/2 KM/31103 10 x 3 330 G1/2 KM/31121 12 x 1 100 G1/2 KM/31122 12 x 2 225 G1/2 KM/31123 12 x 3 330 G1/2 KM/31141 14Ë x 1 125 G1/2 KM/31142 14Ë x 2 265 G1/2 KM/31143 14Ë x 3 380 G1/2
Standard models
Safety note: These actuators must not be pressurised when unrestrained.For exact calculation for compact air bellows please contact our Technical Service.
Port sizeModel Nominal Ø (inch)x convolutions
Maximum stroke(mm)
185
KM/31081 50 130 230 184 155,5 245 6,4 KM/31082 75 250 220 184 155,5 245 7,3 KM/31101 50 150 280 210 181 300 8,5 KM/31102 75 300 270 210 181 300 9,7 KM/31103 100 430 270 210 181 300 10,9 KM/31121 50 150 330 260 232 350 13,2 KM/31122 75 300 325 260 232 350 14,8 KM/31123 100 430 325 260 232 350 16,3 KM/31141 50 175 395 310 282,5 425 18,6 KM/31142 75 340 400 310 282,5 425 19,6 KM/31143 100 480 400 310 282,5 425 20,5
8,5 � �
M10
25B
�
G 1/2
F
D
A
B
A A
Ø NClearance around the air bellow
KM/31000 Stainless steel – standard serviceable air bellows
Serviceable air bellowsStainless steel
KM/31000Single acting
Ø 8 to 14Ë"
B min. B max.(mm) (mm) Ø A Ø D Ø F Ø N kg
Installation heightModel
Actuators
www.norgren.com/info/en192192
Compact air bellowsPM/31000 Single actingØ 2È to 12"
Frictionless operationNo maintenance or lubricationIdeal for short stroke, high-force applicationsHigh vibration isolation levelEasy, compact installation
Technical dataMedium:Compressed air, non-lubricatedOperation:Single acting Operating pressure:8 bar maximumOperating temperature:-40°C to + 70°C for PM/31000(Standard)-25°C to + 90°C for TPM/31000(Butyl)-20°C to + 115°C for EPM/31000(Epichlore)Consult our Technical Service for use below +2°C
Strokes:From 20 to 315 mm max.,depending on diameters andnumber of convolutions
MaterialsEnd plates: plastic (Ø 2È, 6")aluminium (Ø 4") zinc-chromated steel (Ø 8, 9Ê, 12")Central ring: plastic, aluminiumor zinc-chromated steelRubber part: PM/31000: fabricreinforced NR-, SBR-, BR-compound rubber, TPM/31000:fabric reinforced ButylEPM/31000: fabric reinforcedEpichlore
PM/31021 2È" x 1 20 G1/4PM/31022 2È" x 2 45 G1/4PM/31023 2È" x 3 65 G1/4PM/31041 4Ë" x 1 40 G3/8PM/31042 4Ë" x 2 80 G3/8PM/31061 6" x 1 55 G1/2PM/31062 6" x 2 115 G1/2PM/31081 8" x 1 95 G3/4PM/31082 8" x 2 185 G3/4PM/31091 9Ê" x 1 105 G3/4PM/31092 9Ê" x 2 230 G3/4PM/31121 12" x 1 105 G3/4PM/31122 12" x 2 215 G3/4PM/31123 12" x 3 315 G3/4
Standard models
Options selector˙PM/31˙˙˙
Number of convolutions Substitute1 12 23 3
Nominal diameter (inches) Substitute2È 024Ë 046 068 089Ê 0912 12
Air bellow materials SubstituteHigh temperature (Butyl) TExtreme temperature (Epichlore) E
Note: Disregard option positions not used.Safety note: These actuators must not be pressurisedwhen unrestrained.For exact calculation for compact air bellows pleasecontact our Technical Service.
Port sizeModel Nominal Ø (inch)x convolutions
Maximum stroke(mm)
193
3
8
B m
in.
B m
ax.
XA A
ø 6,5
78
36
ø 95
M 6
G 1/4
B m
in. B m
ax.
XA A
G 3/8
93
ø 140
110
ø7
M6
15
6
�
°°°1
20°
B m
in.
B m
ax.
X X1
A A
G 1/2
127
153
ø 190
44,5
M8
ø 8,5
M8
1410
,5
17
°°°°
°°°4
5°
90°
PM/31041, PM/31042
PM/31061, PM/31062
Clearance around the air bellow
Section X
Section X
Section X1
Section X
Clearance around the air bellow
Clearance around the air bellow
Standard air bellowsPM/31021 to PM/31023
G 3/4
F
A
Z
D
A A
X
B m
in.
B m
ax.
ø N
M8
16
PM/31081, PM/31123
Clearance around the air bellow
PM/31061 6 x 1 55 55 110 0,97 PM/31062 6 x 2 115 80 195 1,30
kg
PM/31021 2 È x 1 20 50 70 0,21 PM/31022 2 È x 2 45 65 110 0,26 PM/31023 2 È x 3 65 80 145 0,30 PM/31041 4 Ë x 1 40 50 90 0,73 PM/31042 4 Ë x 2 80 65 145 0,91
PM/31081 8 x 1 95 55 150 PM/31082 8 x 2 185 80 265 PM/31091 9 Ê x 1 105 55 160 PM/31092 9 Ê x 2 230 80 310 PM/31121 12 x 1 105 60 165 PM/31122 12 x 2 215 85 300 PM/31123 12 x 3 315 120 435
Ø A Ø D Ø F Ø N Z kg225 135 70 240 Centric 1,80220 135 70 240 Centric 2,30 255 160 89 275 38 2,30255 160 89 275 38 3,10335 228 157,5 360 73 3,80325 228 157,5 350 73 5,20325 228 157,5 350 73 7,00
Compact air bellowsPM/31000
Single acting
Ø 2È to 12"
Model Nominal Ø(inch) xconvolutions
Strokes(mm)
InstallationheightB min. (mm)
InstallationheightB max. (mm)
kgModel Nominal Ø(inch) xconvolutions
Strokes(mm)
InstallationheightB min. (mm)
InstallationheightB max. (mm)
Model Nominal Ø(inch) xconvolutions
Strokes(mm)
Installation heightB min.(mm)
B max.(mm)
Actuators
www.norgren.com/info/en194194
Frictionless operationNo maintenance or lubricationIdeal for short stroke, high-force applicationsHigh vibration isolation levelSimple to install
Technical dataMedium:Compressed air, non-lubricatedOperation:Single acting Operating pressure:8 bar maximumOperating temperature:-40°C to + 70°C for M/31000(Standard)-25°C to + 90°C for TM/31000(Butyl)-20°C to + 115°C for EM/31000(Epichlore)Consult our Technical Service for use below +2°C
Strokes:From 55 to 430 mm max.,dependant on model
MaterialsEnd plates: zinc-chromated steel(21" = aluminium)Fixing studs: zinc-chromated steelCentral ring: aluminium or zinc-chromated steelRubber part:M/31000: fabric reinforcedNR-, SBR-, BR- compound rubberTM/31000: fabric reinforced butylEM/31000: fabric reinforcedEpichlore
Serviceable air bellowsM/31000Single actingØ 6" to 26"
Options selector˙ M / 3 1 ˙ ˙ ˙
Number of convolutions Substitute1 12 23 3
Nominal diameter (inches) Substitute6 068 0810 1012 1214Ë 1416 1621 2126 26
Air bellow materials SubstituteHigh temperature (Butyl) TExtreme temperature (Epichlore) E
Note: Disregard option positions not used.
M/31061 6" x 1 55 G1/2M/31062 6" x 2 115 G1/2M/31081 8" x 1 80 G1/2M/31082 8" x 2 175 G1/2M/31101 10 x 1 100 G1/2M/31102 10 x 2 225 G1/2M/31103 10 x 3 330 G1/2M/31121 12 x 1 100 G1/2M/31122 12 x 2 225 G1/2M/31123 12 x 3 330 G1/2M/31141 14Ë x 1 125 G1/2M/31142 14Ë x 2 265 G1/2M/31143 14Ë x 3 380 G1/2M/31162 16 x 2 315 G1/2M/31163 16 x 3 430 G1/2M/31212 21 x 2 280 G3/4M/31262 26 x 2 410 G3/4
Standard models
Safety note: These actuators must not be pressurised whenunrestrained.For exact calculation for compact air bellows please contact ourTechnical Service.
Port sizeModel Nominal Ø (inch)x convolutions
Maximum stroke(mm)
195
M/31061 6 x 1 55 50 105 175 153 127 190 2,3M/31062 6 x 2 115 75 190 175 153 127 190 2,6M/31081 8 x 1 80 50 130 230 184 155,5 245 3,0M/31082 8 x 2 175 75 250 220 184 155,5 245 3,7M/31101 10 x 1 100 G1/2 150 280 210 181 300 3,9 M/31102 10 x 2 225 G1/2 300 270 210 181 300 5,0M/31103 10 x 3 330 G1/2 430 270 210 181 300 5,6M/31121 12 x 1 100 G1/2 150 330 260 232 350 5,2M/31122 12 x 2 225 G1/2 300 325 260 232 350 6,7M/31123 12 x 3 330 G1/2 430 325 260 232 350 8,1M/31141 14Ë x 1 125 G1/2 175 395 310 282,5 425 6,9M/31142 14Ë x 2 265 G1/2 340 400 310 282,5 425 9,1M/31143 14Ë x 3 380 G1/2 480 400 310 282,5 425 10,7 M/31162 16 x 2 315 G1/2 390 440 310 282,5 460 9,7M/31163 16 x 3 430 G1/2 550 425 310 282,5 450 12,9M/31212 21 x 2 280 G3/4 370 580 498 470 630 20,6 M/31262 26 x 2 410 G3/4 500 700 498 470 750 23,0
8,5 � �
M10
25B
�
G 1/2
F
D
A
B
A A
Ø N
�
B
B
150
60°
D
F
A
A A
ø N
G 3/4
M10
x15 *
Standard air bellowsM/31061 to M/31163
M/31212, M/31262
Clearance around the air bellow
Clearance around the air bellow
Serviceable air bellowsM/31000
Single acting
Ø 6" to 26"
kg
Ø A Ø D Ø F Ø N
Model Nominal Ø(inch) xconvolutions
Strokes(mm) B min. (mm) B max. (mm)
Installation height
Valves
www.norgren.com/info/en330330
Solenoid operating details
Valves for type A solenoid
Reversible seal allows 3/2 or 5/2 wayfunctionExhaust air recirculationCrossover-free switching, switch-overfunction guaranteed even with smallcross section air supplySafety function in the evennt of powerfailure provided by mechanical returnspring (monostable design)Add-on manual overrideSuitable for outdoor installation ifequipped with corresponding solenoidValves suitable for hazardouusenvironments in combination with Exapproved solenoids (ATEX, FM) Minimal electrical power consuumption –therefore many safety ratings possible,e.g. EEx ia
Technical dataMedium:Compressed air, filtered, lubricated andnon-lubricated, instrument air, nitrogenor other neutral, dry fluids Flow direction:Fixed Mounting position:Optional Operating pressure:2 to 8 bar with internal air supply Temperature range:Valve: -40°C to +65°CSolenoid: see solenoid tableFor temperatures below 0°C use conditioned dry air. Ifinstalled outdoors protect all connections against thepenetration of moisture
MaterialsHousing: aluminium black anodized,brass, stainless steel 1.4305Seal: NBR (Perbunan)
G1/4 Flange 5/2 Solenoid/Spring Aluminium 1300 0,45 9710505xxxx*****1/4 NPT Flange 5/2 Solenoid/Spring Aluminium 1300 0,45 9710515xxxx*****G1/4 Flange 5/2 Solenoid/Solenoid Aluminium 1300 0,65 9711505xxxx*****1/4 NPT Flange 5/2 Solenoid/Solenoid Aluminium 1300 0,65 9711515xxxx*****G1/4 Flange 5/3 NC Solenoid/Solenoid Aluminium 950 0,70 9712505xxxx*****1/4 NPT Flange 5/3 NC Solenoid/Solenoid Aluminium 950 0,70 9712515xxxx*****Flange Flange 3/2 Solenoid/Spring Aluminium 1300 0,43 9710525xxxx*****#G1/4 Flange 5/2 Solenoid/Spring Brass 1300 1,00 9710605xxxx*****1/4 NPT Flange 5/2 Solenoid/Spring Brass 1300 1,00 9710615xxxx*****G1/4 Flange 5/2 Solenoid/Solenoid Brass 1300 1,40 9711605xxxx*****1/4 NPT Flange 5/2 Solenoid/Solenoid Brass 1300 1,40 9711615xxxx*****G1/4 Flange 5/3 NC Solenoid/Solenoid Brass 950 1,50 9712605xxxx*****1/4 NPT Flange 5/3 NC Solenoid/Solenoid Brass 950 1,50 9712615xxxx*****Flange Flange 3/2 Solenoid/Spring Brass 1300 0,90 9710625xxxx*****#G1/4 Flange 5/2 Solenoid/Spring Stainless steel 1300 1,00 9710705xxxx*****1/4 NPT Flange 5/2 Solenoid/Spring Stainless steel 1300 1,00 9710715xxxx*****G1/4 Flange 5/2 Solenoid/Solenoid Stainless steel 1300 1,40 9711705xxxx*****1/4 NPT Flange 5/2 Solenoid/Solenoid Stainless steel 1300 1,40 9711715xxxx*****G1/4 Flange 5/3 NC Solenoid/Solenoid Stainless steel 950 1,50 9712705xxxx*****1/4 NPT Flange 5/3 NC Solenoid/Solenoid Stainless steel 950 1,50 9712715xxxx*****Flange Flange 3/2 Solenoid/Spring Stainless steel 1300 0,90 9710725xxxx*****#
# NAMUR interface DIN 3845/Nov. 98, port P and auxiliary supply in flange surfacexxxx Insert solenoid codes from table below. ***** Insert voltage codes from table below
Power consumption Protection class Temperature °C Electrical Solenoid24 V d.c. 230 V a.c. Fluid Ambient connection code
Requires connector plug type 0570275 for d.c., connector plug with rectifier type 0663303 for a.c. or a.c./d.c. For connector plugs and accessories see page 384
97105 SeriesIndirect solenoid actuated spool valvesFor single and double acting actuators with NAMUR interface3/2, 5/2, 5/3, GÊ, Ê NPT
Min, RequiredNominal required voltage atresistance switching Resistance terminal SolenoidRV coil currennt RW 60 coil RW 65 code
Solenoid actuators (ATEX) for intrinsically safe circuitCat. II 1G EEx ia IIC T5/T6*, Cat. II 2D T 90°C
When selecting an intrinsically safe power supply, the permissible maximum values according to the EC-Type Examinationcertificate KEMA 03 ATEX 1051X must be taken into account. The low effective inductivity and capacity can be ignored.*Fluid and ambient temperature: -40 to +80°C (T5), -40 to +70°C (T6)
Min, RequiredNominal required voltage at Temperatureresistance switching Resistance terminal °C SolenoidRRV coil current RW 65 coil RW 65 Fluid Ambience code
Solenoid actuators with FM approvalIntrinsically safe: IS/I, II, III/1/ABCDEFG/T6 Ta = 65 °C; I/0 AEx ia IIC/T6 Ta = 65 °C - 0588672/B; EntityNonincendive: NI/I/2/ABCD/T6 Ta = 65 °C; S/II,III/2/FG/T6 Ta = 65 °C; NEMA Type 4
When selecting an intrinsically safe power supply, the permissible maximum values according to the FM approvalshould be taken into account. The low effective inductivity and capacity can be ignored.
200 ∆ 33 mA 240 ∆ 8 V 2050391 ∆ 24 mA 470 ∆ 11 V 2051736 ∆ 17 mA 880 ∆ 15 V 20521220 ∆ 13 mA 1460 ∆ 19 V 2053
124 ∆ 43 mA 150 ∆ 6,4 V -40 ... +65 +65 2040159 ∆ 38 mA 193 ∆ 7,3 V -40 ... +65 +65 2041198 ∆ 34 mA 240 ∆ 8,2 V -40 ... +65 +65 2042248 ∆ 30 mA 301 ∆ 9,0 V -40 ... +65 +65 2043306 ∆ 27 mA 371 ∆ 10,0 V -40 ... +65 +65 2044378 ∆ 25 mA 458 ∆ 11,5 V -40 ... +65 +65 2045467 ∆ 23 mA 566 ∆ 13,0 V -40 ... +65 +65 2046566 ∆ 21 mA 686 ∆ 14,4 V -40 ... +65 +65 2047692 ∆ 19 mA 839 ∆ 15,9 V -40 ... +65 +65 2048
21312
12 10
Port size1/3 (5) 2 (4)
kg ModelFlow (l/min)Function Actuation Materials
24 V d.c. 0240024 V a.c. 02450110 V a.c. 11050230 V a.c. 23050
Voltage codesCodeVoltage
1,6 W IP 00 (without connector) +80 -15 ... +50 02531,9 W IP 00 (without connector) +50 -15 ... +50 07633,2 W Cat II 2 G EEx m II T5 +70 +70 0298
3,5 VA Cat II 2 G EEx m II T5 +70 +70 02990,7 W Cat II 2 GD EEx me II T5/T6 -40 ... +80/70 4200
1,3 VA Cat II 2 GD EEx me II T5/T6 -40 ... +80/70 42010,7 W Cat II 2 GD EEx md IIC T5/T6 -40 ... +80/70 -40 ... +80/70 1/2 NPT 46000,7 W Cat II 2 GD EEx md IIC T5/T6 -40 ... +80/70 -40 ... +80/70 M20x1,5 4602
1,3 VA Cat II 2 GD EEx md IIC T5/T6 -40 ... +80/70 -40 ... +80/70 1/2 NPT 46011,3 VA Cat II 2 GD EEx md IIC T5/T6 -40 ... +80/70 -40 ... +80/70 M20x1,5 46031,4 W NEMA 4, 4X, 6, 6P, 7, 9; wire 460 mm -20 ... +60 -20 ... +60 3720
331
97105 SeriesIndirect solenoid actuated spool valves
For single and double acting actuators with NAMUR interface
3/2, 5/2, 5/3, GÊ, Ê NPT
3.3
13.821.8
110.8
4.3
3.5
92.8
335.1
51.5
3245
4
101
36.6
47.1
57.6
59.1
27.5
315
4.8
13.827
.5
33 22 22
43
134
4.3
3.5
116
43
67
3245
4.35
105.
5
3 1 5
27.5
4.3
162.2
4.8
13.827
.5
46
61.5
83.5
105.5
204
71.5
95.5
32
3.4
3.5
4510
5.5
3 1 5
27,5
4,3
180
4,8
13,827
,5
46
79
101
123
222
89,3
113,3
32
3,4
3,5
4510
5,5
3/2 NAMUR DIN 3845/Nov. 98 5/2 Single solenoid model 5/2 Double solenoid model
5/3 Double solenoid model
EEx m
4133
82,5
89
19,5
63,5
73
IP 00, 0253
40,5
38
15,5
55
74
18
29,5
*
Pg 11
27,5
12
EEx me
54,5
107
64,5
91,5
42M 20 x 1,5
27
ø 13
40,5
Solenoids
NEMA
40,5
63
84
33,5
43
26
2
1/2 - 14 NPT
*
IP 00, 0763
40,5
49
17
56
53,5
27
89
3443
Pg 11 12
*
27,5
EEx ia
6066
80
63Pg 13,5
33
Ø16*
�
119
416
62
FM
6066
97,5
63
1/2-14 NPT
33
Ø16*
119
416
62
* Connector rotates 4 x 90°
* Connector rotates 4 x 90°
* Ø 13 (with spacer tube)
* Ø 13 (with spacer tube)
* Stranded wire AWG 18 (~460 mm length)
Valves
www.norgren.com/info/en332332
Reversible seal allows 3/2 or 5/2way functionExhaust air recirculationCrossover-free switching, sswitch-over function guaranteed evenwith small cross section airsupplySafety function in the evennt ofpower failure provided bymechanical return spring(monostable design)Suitable for outdoor insstallation ifequipped with correspondingsolenoid
Technical dataMedium:Compressed air, filtered, lubricatedand non-lubricated, instrument air,nitrogen or other neutral, dry fluids Flow direction:Fixed Mounting position:Optional Operating pressure:2 to 8 bar with internal air supply Temperature range:Valve: -40°C to +65°CSolenoid: see solenoid tableFor temperatures below 0°C use conditioned dry air. Ifinstalled outdoors protect all connections against thepenetration of moisture
MaterialsHousing: aluminium black anodized,brass, stainless steel 1.4305Seal: NBR (Perbunan)
97105 Series (50 mW/5 mW)Indirect solenoid actuated spool valvesFor single and double acting actuators with NAMUR interface3/2, 5/2, 5/3, GÊ, Ê NPT
# NAMUR interface DIN 3845/Nov. 98, port P and auxiliary supply in flange surfacexxxx Insert solenoid code from table below yyy Insert electrical connection code from table below
* Category II2G, EC Type Examination Certificate No. PTB 00 ATEX 2050
G1/4 Flange 5/2 Solenoid/Spring 1300 0,45 9710509xxxxyyy001/4 NPT Flange 5/2 Solenoid/Spring 1300 0,45 9710519xxxxyyy00G1/4 Flange 5/2 Solenoid/Solenoid 1300 0,65 9711509xxxxyyy001/4 NPT Flange 5/2 Solenoid/Solenoid 1300 0,65 9711519xxxxyyy00G1/4 Flange 5/3 NC Solenoid/Solenoid 950 0,70 9712509xxxxyyy001/4 NPT Flange 5/3 NC Solenoid/Solenoid 950 0,70 9712519xxxxyyy00Flange Flange# 3/2 Solenoid/Spring 1300 0,43 9710529xxxxyyy00
Rated Voltage at Rated Rated Resistance Max. values EEx i Type of Ambient Solenoidpower terminal current current coil Ui Ii Pi protection* temperature codePN UN Ion Ioff RN5 mW ∫ 5 V ∫ 1 mA √ 0,1 mA 5100 ∆ 28 V 120 mA 0,75 W EEx ia IIC T4 -40 ... +80°C 2080
25,2 V 155 mA 0,75 W EEx ia IIC T6 -40 ... +45°C22 V 224 mA 0,75 W
50 mW ∫ 10 V ∫ 2,7 mA √ 1,3 mA 3700 ∆ 28 V 120 mA 0,75 W II 2G EEx ia IIC T4 -40 ... +65°C 208125,2 V 155 mA 0,75 W II 2G EEx ia IIC T6 -40 ... +45°C22 V 224 mA 0,75 W
21312
12 10
Solenoid operating details
Connector CodeM12 x 1,5 003Round connector 004M16 x 1,5 005
Electrical connections
Port size1/3 (5) 2 (4)
kg ModelFlow (l/min)Function Actuation
333
97105 Series (50 mW/5 mW)Indirect solenoid actuated spool valves
For single and double acting actuators with NAMUR interface
3/2, 5/2, 5/3, GÊ, Ê NPT
3
30
101
45
32
51,5
35,1
24
94109
59,8
82,6
47
3
14
28
22004
003
002
001
3
2
41
5
24
27
13
17,5
4.8
13,8
27,5
67
89,5
3322
22
4,35
11713
2
101
45
43 4324 1
32
Pg11
Pg9
3
12
4
5
2522
22
101
163
45
3524
4,35
32
30
9
1,2
35
89,6
67
4,8
13,8
27,5
3
12
4
5
004
003
002
001
Pg11
2517
,822
22
101
180,
8
45
3524
4,35
32
30
9
1.2
35
89,6
67
4,8
13,8
27,5
24
27
13
17,5
Pg11
Pg9
120,
8
3/2 NAMUR DIN 3845/Nov. 98 5/2 Single solenoid model
5/2 Double solenoid model
5/3 Double solenoid model
Fluid controlsolutionsNorgren is a leading global supplier of Fluid control
solutions with proven products widely accepted by
manufacturers and users worldwide.
The winning combination of Norgren, Herion and
Buschjost expertise and technology brings you all the
benefits of many years of specialized experience and
understanding of the process industry applications.
Norgren is committed to providing added value
through machine and process improvement and this is
further backed by our commitment to provide an
unequalled service which is customized to meet the
specific needs of our individual customers.
At the heart of this service is the capability to design
and engineer added-value, integrated solutions to
answer the most demanding applications challenges.
A new Fluid Control catalogue will be available soon.You can visit www.norgren.com for more information onthese products.
• Control flow of air, water, oil and otherfluids and gases
• 2/2 and 3/2 valves
~ Diaphragm and piston seat type
~ Pressure range up to 40 bar (specials upto 70 bar); medium temperature -196°Cup to +200°C
~ Can be operated by solenoid, by air-driven actuator and by motor drive
~ In-line and Namur versions
~ Threaded connections 1/4 to 3 inches(BSP or NPT) and flanged connections1/2 to 6 inches (DIN or ANSI)
~ Low power consumption options (5 mW and 50 mW)
~ Bodies in brass, grey cast iron, cast andstainless steel, gun metal, plastic,anodised aluminium
• Options suitable for hazardous areas
• Models for Emergency Shut-off Applications
• Control systems
• BUS – Technology
• Valve systems (manifold or fitted withpipes)
• Customized standard products and specialdesigns
• TÜV approval, including risk analysis forpetrochemical plants
• Ex-approvals worldwide
Solenoids, with ATEX approval inprotection classes: EEx m II T4, EEx me II T3/4, EEx de II C T4/5, EEx md,Eex na, Eexia. NI, IS, XP
Approvals
24011/24010 solenoid valves, Namur andInline with TÜV Approval IEC 61508
97105 Series indirect solenoid valves,Namur and Inline for -40°C
Pressure actuated angle seat valves
Click-on® piston valves
Motorised valves
Dust filter valves pressure actuated
Click-on® diaphragm valve
Twist-on® Dust filter valves solenoidactuated
Valves
www.norgren.com/info/en356356
VP10 SeriesProportional pressure control valveGÊ
Robust proportional I/P and E/P convertersSuitable for a wide range of applicationsHigh accuracyHigh flow versions availableIP 65 protection in normal operation
Technical dataMedium:Compressed air filtered to 5 µm, oil-free, dryOutput signal:0,2 to 1,0 bar, 0,2 to 2,0 bar, 0,2 to 4,0 bar (2 wireversion), 0,14 to 6 bar, 0,14 to 8 bar (3 wireversion) Flow:Up to 300 l/min Air consumption:<4 bar: 0,85 l/min typical at 50% signal>4 bar: 1,75 l/min typical at 50% signalOperating pressure:At least 0,7 bar above maximum required outputpressure range Ambient temperature:-40°C to +85°C Consult our Technical Service for use below +2°C.
Mounting:Integral surface mounting bracket provided forpreferred vertical mounting. 50 mm pipe mountingkit available Response time:<2 bar: less than 0,5 seconds (dependent on input for 10 to 90% step change andoutlet pressures)>2 bar: 2 seconds for 10 to 90% step change Total error:±0,5% of span (typical, independent error includesthe combined effect of non-linearity, hysteresis,deadzone and repeatability) Temperature effect:Average 0,1% of span/°C for span and zero overoperating range Supply sensitivity:< 0,075% span output change per % supplypressure change Failure mode:Signal falls to bleed pressure when electrical supplyfails Weight:0,825 kg
MaterialsBody: passivated zinc die-casting, epoxy paintedDiaphragms: nitrileInternal: beryllium copper/brassFlapper nozzle and supply valve: stainlesssteel/nylon
Electrical informationElectromagnetic compatibility This is a passive electromagnetic instrument and is unaffected by interfering high
frequency signalsElectrical signal Two wire version 4 to 20 mA or 0 to 10 V
Three wire version requires 12 to 24 V d.c. supplyConnections 30 mm square connector DIN 43650 provided, mountable in four directions
(alternative connections available)
67
51
105
5440
73
548
*
**
*******
Supply in Output
Front view
* Range or span (typical)** 2 holes Ø 6,5 mm*** Removable orifice**** Plug orients 4 ways
0 ... 10 V 0,2 ... 1 VP1001BJ100A004 ... 20 mA 0,2 ... 1 VP1001BJ400A000 ... 10 V 0,2 ... 2 VP1002BJ100A004 ... 20 mA 0,2 ... 2 VP1002BJ400A000 ... 10 V 0,2 ... 4 VP1004BJ100A004 ... 20 mA 0,2 ... 4 VP1004BJ400A000 ... 10 V 0,14 ... 6 VP1006BJ101A004 ... 20 mA 0,14 ... 6 VP1006BJ401A000 ... 10 V 0,14 ... 8 VP1008BJ101A004 ... 20 mA 0,14 ... 8 VP1008BJ401A00
ModelControl signal Output pressure (bar)
357
VP10 SeriesProportional pressure control valves
GÊ
Characteristic curves
Forward flow characteristics(Supply pressure 7 bar)
Relief flow characteristics(Supply pressure 7 bar)
Flow (l/min) Flow (l/min)O
utle
t pr
essu
re (
bar)
Out
let
pres
sure
(ba
r)O
utle
t pr
essu
re (
bar)
Span/zero adjustments
Input signal
20% ofoutputrange
Pressure switches
www.norgren.com/info/en388388
20 D SeriesFor low-pressure pneumatics0 to 1,6 bar
High accuracyMicroswitch with gold-plated contacts(silver plated for field mounting)Electrical coonnection:Connector acc. to DIN 43650 orscrewed cable gland
Technical dataMedium:Neutral gases and liquids (water,hydraulic oil, lubricants, light gas oil)Mounting position:OptionalOperating pressure:0 to 16 barAmbient temperature:0 °C to +60 °C-40 °C to +80 °C (weather-proof*)* On requestConsult our Technical Service for use below +2°C.
Viscosity:Max. 1000 mm2/sFluid temperature:0 °C to +80 °CTemperature at switchingelement:+80 °C max.Seal rate:> 10-7 mbar•I•s-1Repeatability:±1% of final value (referred topressure control)Vibration immunity:max. 5 Hz/4 g (sinosoidal)To be avoidedSwitching cycles:max. 10/minuteDegree of protection:IP65
MaterialsHousing: aluminium die cast,aluminium die cast, tin plated (field)Sensor: steel 1.0333, St. st.1.4305/1.4301, brassSealing: Plastic diaphragm (Perbunan)or Viton (FKM)
Fixed switching pressure differences
Adjustable switching pressure differences
Variant codes (YY)
00 Steel/1.0333 / NBR DIN 43650* G1/4 female –05 Steel/1.0333 / NBR M20 x 1,5 G1/4 female –
NPTF port sizes on request* Connector not within scope of supply. If required please order separately, part no. 0570110** Special pressure ranges on request*** Typical values
1
2 3
p
Pressurerange (bar)**
Over pressure(bar)
Switching pressure difference (bar)*** Drawing no.Range start Range end
Model
Pressurerange (bar)**
Code Materials Electrical connection Fluid port size Options
Over pressure(bar)
Switching pressure difference (bar)***Range start Range end Max.
Model
0 ... 0,025 0,5 0,003 0,004 1 18125YY0 ... 0,06 0,5 0,004 0,006 1 18126YY0 ... 0,16 0,5 0,004 0,008 1 18127YY0 ... 0,25 0,5 0,004 0,009 1 18128YY0,05 ... 0,6 15 0,03 0,06 2 18141YY0,05 ... 1,6 15 0,03 0,12 2 18143YY
0 ... 0,025 0,5 0,008 0,011 0,025 1 18025YY0 ... 0,06 0,5 0,009 0,015 0,04 1 18026YY0 ... 0,16 0,5 0,011 0,023 0,12 1 18027YY0 ... 0,25 0,5 0,011 0,028 0,2 1 18028YY0,05 ... 0,6 15 0,09 0,16 0,5 2 18041YY0,05 ... 1,6 15 0,13 0,25 1,2 2 18043YY
Drawing no.
389
20 D SeriesFor low-pressure pneumatics
0 to 1,6 bar
43,8��
46,8��
104��
Ansicht H��
M4 x 10 tief�
�
5,8��
43,5��
22��
C��
C��
D��
D��
A��
A��
50,7
��
22� �
81� �
70� �
5� �
19��
1,8��
19��
115,5��
H��
Standard housingFor electrical and pneumatic connectors see below
Load level Type of Type of load Umin Maximum permanent current Imax [A] at U [V] Contact life #current [V] 30 48 60 125 250 electrical mechanical
at Imax at I Ÿ 0Standard * a.c. Resistive load 12 5 5 5 5 5 5 x 104 >107
(e.g. contractors, switching switchingsolenoids) a.c. Inductive load, 12 3 3 3 3 3 cycles cycles
cos Ÿ 0,7d.c. Resistive load 12 5 1,2 0,8 0,4 –d.c. Inductive load, 12 3 0,5 0,35 0,05 –
L/R Ÿ 10 msLow ** a.c. Resistive load 5‡ 0,34 0,2 0,17 0,08 0,04 2 x 105 > 107
(e.g. electronic switching switchingcircuits) d.c. Inductive load, 5‡ 0,1 0,01 – – – cycles cycles
L/R Ÿ 10 msReference number of switchings: 30/min, reference temperature: +30°CSpark quenching with diode with d.c. and inductive load: Imax = 1.5 x Imax of table Imin = 1 [mA]Creepage and air paths correspond to insulation group B according to VDE reg. 0110 (except contact clearance of microswitch).* Gold-plating not required as it would decay. Maximum permitted in-rush current (approximately 30 ms) a.c. make = max. 15A.**Gold-plating required (will not decay).# 50% of the respective switching current I nearly doubles contact life. The mechanical life depends on the field of application.‡ Lower value of critical voltage guarantees sufficient contact safety. Lower voltages permissible under favourable conditions.
View H
21,2��
30� �
9,2��
D��
2232,5
M 2
0 x
1,5
6 ø 6,5 - 8,8
Electrical connectionDIN 43650
Electrical connectionM20 x 1,5
G 1/4
ø 132
~ 15
0
A��
ø 64
G 1/4
~ 46
A��
AccessoriesPlease see page 392 for details of plugs, brackets, surgedampers and adaptors.
1 2
Pressure switches
www.norgren.com/info/en390390
High accuracyGold-plated contactsWith Ex-Versions acc. to ATEX 100aWeatherproof (silver-platedcoontacts)Power supply connections:DIN 43650 plug or screwed cablegland
Technical dataMedium:For neutral and aggressive gasesand liquidsMounting position:Optional, preferably with pressureconnection underneath Ambient temperature:-25°C to +80°C-40°C to +80°C (weatherproof) Consult our Technical Service for use below +2°C.
Viscosity:Up to 1000 mm2/s (±450 ssu). Fluid temperature:-10°C to +100°C Temperature at switchingelement:+80°C Seal rate:>10-7 mbar·l·s-1 Repeatability:±1% from range end value(depending on pressure regulation) Degree of protection:IP 65
MaterialsBrass, stainless steel: see table
AlternativemodelsFor power plants, part no. 18XXX12with Harting connector type HAN 7Dincluding 47 K ∆ wire breakingmonitoring, G1/2 male stainlesssteel, Pg16Ex-Versions acc. to ATEX 100a onrequest
20 D Series (Allfluid)For pneumatics, aggressive gases and liquids-1 to 100 bar
Adjustable switching pressure differences
YY = replace with code from table below
Variant codes (YY)
# Plug not included. If required, order model 0570110, see page 384
* Not for pressure sensor variants 00 and 05 ** Only for pressure sensor variants 10 and 15*** Typical values
-1 ... 0 10 0,12 0,13 0,7 0,12 0,13 0,7 18001YY-1 ... 1 10 0,13 0,14 1,00 0,19 0,21 1,00 18002YY-1 ... 2,5 10 0,17 0,20 2,50 0,22 0,24 2,50 18004YY0,05 ... 1 10 0,08 0,11 0,70 0,15 0,16 0,70 18011YY0,1 ... 2,5 10 0,11 0,15 2,00 0,20 0,25 2,00 18013YY0,5 ... 4 20 0,30 0,40 2,50 0,80 0,80 2,50 18014YY0,5 ... 6 20 0,35 0,50 5,00 0,80 0,90 5,00 18015YY0,5 ... 10 20 0,40 0,80 8,00 0,90 1,90 8,00 18016YY1 ... 16 50 0,80 1,10 12,00 1,70 2,00 12,00 18017YY1 ... 25 50 1,00 1,50 20,00 1,80 2,80 20,00 18018YY5 ... 63 85 2,00 3,00 20,00 2,30 3,50 20,00 18019YY*5 ... 100 150 3,50 7,00 55,00 4,00 9,00 55,00 18010YY**
00 Brass/stainless steel 1.4404 DIN 43650# G1/4 Internal thread –05 Brass/stainless steel 1.4404 M20 x 1,5 G1/4 Internal thread –10 Stainless steel 1.4305, 1.4404 DIN 43650# G1/2 External thread –15 Stainless steel 1.4305, 1.4404 M20 x 1,5 G1/2 External thread –20 Stainless steel 1.4571 DIN 43650# G1/2 External thread –21 Stainless steel 1.4571 M20 x 1,5 G1/2 External thread Weatherproof25 Stainless steel 1.4571 M20 x 1,5 G1/2 External thread –
1
2 3
p
Switchingpressurerange (bar)
Overpressure(bar)
Switching pressure difference (bar)***Code 00, 10, 20Range start Range end
Min. Max. Min. Max.
Switching pressure difference (bar)***Code 05, 10, 15, 21, 25Range start Range end
Model
Code Materials Electrical connection Fluid port size Options
Fixed switching pressure differences
-1 ... 0 10 0,06 0,07 0,02 0,03 0,06 0,07 18101YY-1 ... 1 10 0,06 0,08 0,07 0,10 0,07 0,08 18102YY-1 ... 2,5 10 0,08 0,12 0,09 0,12 0,09 0,12 18104YY0,05 ... 1 10 0,06 0,08 0,07 0,08 0,07 0,08 18111YY0,1 ... 2,5 10 0,07 0,09 0,09 0,10 0,11 0,15 18113YY0,5 ... 4 20 0,20 0,25 0,30 0,33 0,30 0,33 18114YY0,5 ... 6 20 0,20 0,30 0,30 0,35 0,30 0,35 18115YY0,5 ... 10 20 0,30 0,40 0,30 0,40 0,30 0,40 18116YY1 ... 16 50 0,60 0,80 0,70 0,80 0,70 0,80 18117YY1 ... 25 50 0,70 0,90 0,70 0,90 0,70 0,90 18118YY5 ... 63 85 0,90 1,50 1,00 2,00 1,00 2,00 18119YY*5 ... 100 150 2,50 5,00 3,00 7,00 3,00 7,00 18110YY**
Switchingpressurerange (bar)
Overpressure(bar)
Switching pressure difference (bar)***Code 00, 10, 20Range start Range end
Switching pressure difference (bar)***Code 21Range start Range end
Switching pressure difference (bar)***Code 05, 15, 25Range start Range end
Model
391
20 D Series (Allfluid)For pneumatics, aggressive gases and liquids
-1 to 100 bar
43,8��
46,8��
104��
Ansicht H��
M4 x 10 tief�
�
5,8��
43,5��
22��
C��
C��
D��
D��
A��
A��
50,7
��
22� �
81� �
70� �
5� �
19��
1,8��
19��
115,5��
H��
Standard housingFor electrical and pneumatic connectors see below
Load level Type of Type of load Umin Maximum permanent current Imax [A] at U [V] Contact life #current [V] 30 48 60 125 250 electrical mechanical
at Imax at I Ÿ 0
Reference number of switchings: 30/min, reference temperature: +30°CSpark quenching with diode with d.c. and inductive load: Imax = 1.5 x Imax of table Imin = 1 [mA]Creepage and air paths correspond to insulation group B according to VDE reg. 0110 (except contact clearance of microswitch).* Gold-plating not required as it would decay. Maximum permitted in-rush current (approximately 30 ms) a.c. make = max. 15A.**Gold-plating required (will not decay).# 50% of the respective switching current I nearly doubles contact life. The mechanical life depends on the field of application.‡ Lower value of critical voltage guarantees sufficient contact safety. Lower voltages permissible under favourable conditions.
View H
Standard * a.c. Resistive load 12 5 5 5 5 5 5 x 104 >107
(e.g. contractors, switching switchingsolenoids) a.c. Inductive load, 12 3 3 3 3 3 cycles cycles
cos Ÿ 0,7d.c. Resistive load 12 5 1,2 0,8 0,4 –d.c. Inductive load, 12 3 0,5 0,35 0,05 –
L/R Ÿ 10 msLow ** a.c. Resistive load 5‡ 0,34 0,2 0,17 0,08 0,04 2 x 105 > 107
(e.g. electronic switching switchingcircuits) d.c. Inductive load, 5‡ 0,1 0,01 – – – cycles cycles
L/R Ÿ 10 ms
21,2��
30� �
9,2��
D��
2232,5
M 2
0 x
1,5
6 ø 6,5 - 8,8
Electrical connectionDIN 43650
Electrical connectionM20 x 1,5
Pressure switches
392
20 D Series (Allfluid)For pneumatics, aggressive gases and liquids
-1 to 100 bar
Surge damper
G1/4
G1/4
ø21,5
34
46SW22
Plug (black) with LED3 poles mains earth connector according to DIN43650 for d.c. or a.c.
3 pole plug with protective earthconductor
Pressure switch with indicator and light insertThe light insert shows the switching position of the connected pressure switch
39 34
70
27,51,5
34
53
1
2
3
1
2
3
Druckschalter�mit Stiftplatte
Steckdose Umsteckbarer Lampeneinsatz�wahlweise steckbar auf Öffner (2oder Schließer (3)
4 *4 *
44
�
Bracket (2 clips and 4 screws)
104
129
141
5,812
3
14
118Pressure switchwith DIN 43650
*For contact 4 a special supplyline is required
Plug Plug selectable light insert – connection either onnormally closed contact (2 ports) or on normally opencontact (3 ports)
Description ModelWith LED 12 to 28 V 0585418With fibre lamp 90 to 130 V 0585419With fibre lamp 180 to 240 V 0585420
Description ModelDIN 43650 0570110
Description ModelSteel 0574772Stainless steel 0553908
Description ModelStainless steel 0553258Brass/steel 0574773
43,2
��
37��
B��
SW32��
53� �
37��
B��
SW32��
5� �
25� �
61,7
��
SW32��
37��
A��
G1/2 A��
ø6��
43� �
G1/4-12��
47,5��
SW41��
B��
61� �
47,5��
B��
SW41��
52� �
47,5��
B��
SW41��
42,5
��
ø51��
SW30��
B��
47� �
ø40��
SW24��
B��
Pressure sensor variations
18110YY / 18010YYG1/2 10, 15, 20, 21, 25
18119YY / 18019YYG1/2 10, 15, 20, 21, 25
18118YY / 18018YY18117YY / 18117YY
G1/2 10, 15, 20, 21, 25
18116YY / 18016YY18115YY / 18115YY18114YY / 18114YY
G1/2 10, 15, 20, 21, 25
18113YY / 18013YY18111YY / 18011YY18104YY / 18004YY18102YY / 18002YY18101YY / 18001YY
G1/2 10, 15, 20, 21, 25
18118YY / 18018YY18117YY / 18017YY
G1/4 00, 05
18116YY / 18016YY18115YY / 18015YY18114YY / 18014YY
G1/4 00, 05
18113YY / 18013YY18111YY / 18011YY18104YY / 18004YY18102YY / 18002YY18101YY / 18001YY
G1/4 00, 05
G 1/2 female, 1/2 NPT maleStainless steel 1.4305 (AISI 303/304 S)Type 0553831
G 1/4 male - G 1/2 maleStainless steel 1.4305 (AISI 303/304 S)Type 0550083
G 1/4 male - G 3/8 femaleSteelType 0574764
G 1/4 male - 1/4 NPT femaleBrassType 0574765
22,5
43,5
G1/4-14 NPT
SW 27
43,5
1/2 NPT
G1/4
12
22,5
G1/4
12
13
36
Ø21,5
G1/4
30 6,512
Ø20
Reducing nipple for pressure connection
393
Robust sensor for hydraulic applicationsTemperature compensated3-wire technology (0 to 10 V)2-wirre technology (4 to 20 mA)Excellent long-term stabilityStainless steel measuring element-not oil-fiilled
Technical dataMedium:For neutral and aggressive gases or fluidsFluid connection:G1/4 male with nipple manometer connectionMounting position:OptionalPressure range:0 to 800 barFluid temperature:-20°C to +85°C(-40°C to +120°C versions available on request)Ambient temperature:-20°C to +85°C(-40°C to +120°C versions available on request)Consult our Technical Service for use below +2°C.
Degree of protection:IP 65 (acc. to DIN 40050)Shock protection:30g, xyz, to DIN EN 60068-2-27Vibration protection:3g, 5 to 500 Hz, xyz, DIN EN 60068-2-6Electrical connection:M12 x 1/cable (on request)Supply voltage:UB = 12 to 30 V d.c. (current output)UB = 15 to 30 V d.c. (voltage output)max. 10% residual ripple within UBOutput signal:4 to 20 mA (Two-wire technology)0 to 10 V (Three-wire technology)Varying frequency output on requestElectromagnetic compatibility:Interference immunity acc. to EN 50081. Part 1Interference immunity acc. to EN 50082. Part 2Load resistance:See diagramPolarity:Short-circuit proofMeasuring range:See table belowLinearity:< ±0,5% final value
18 S Allfluid SeriesAllfluid/hydraulic applications with relative pressureAllfluid pressure sensor analog, 0 to 800 bar
P
I
P
U
Output signal
Standard versions (electrical connection M 12 x 1)*
0862170 0 ... 10 40 4 ... 20 mA0862180 0 ... 10 40 0 ... 10 V0862370 0 ... 25 50 4 ... 20 mA0862380 0 ... 25 50 0 ... 10 V0862470 0 ... 100 200 4 ... 20 mA0862480 0 ... 100 200 0 ... 10 V0862670 0 ... 250 500 4 ... 20 mA0862680 0 ... 250 500 0 ... 10 V0862770 0 ... 400 750 4 ... 20 mA0862780 0 ... 400 750 0 ... 10 V0862970 0 ... 800 1000 4 ... 20 mA0862980 0 ... 800 1000 0 ... 10 V
Measuring range (bar)(Relative pressure)**
Value max. (bar)(Over pressure)
* Plug not included. Please see below.** Other measurement ranges on request.
Electrical connection M 12 x 14 ... 20 mA 0 ... 10 V
+ UB 1 1GND - 3Signal 4 4
3 2
4 1
* Frequency output available on request.
0862˙˙0
Measuring range relative pressure Code0 to 10 bar 10 to 25 bar 30 to 100 bar 40 to 250 bar 60 to 400 bar 70 to 800 bar 9
Output signal Code4 to 20 mA 70 to 10 V 8
Options selector
Signal Frequency*
Hysteresis:< 0,15%Temperature sensitivity (zeropoint):Zero point < ± 0,4% FS/10KRange < ± 0,2% FS/10K
MaterialsHousing: stainless steel 1.4571/1.4542Sensor: stainless steel membrane 1.4542
Model
www.norgren.com/info/en393
Air line equipment
www.norgren.com/info/en472472
Options selector
Protect compressed air systems fromover-pressurisationSimple, low cost ‘Pop’ type units fordirectt connection to pressure vesselsand associated componentsPre-set and tamper resistant reliefvalvess protected from ingress
Technical dataMedium:Compressed air onlyAmbient temperature:-40°C to +230°C (1002)-20°C ... +80°C (61B2)-4°C ... +40°C (V05)Consult our Technical Service for use below +2°C
Materials1002:Body & adjusting cap: brassBall seal: stainless steel61A2, 61B2:Body & adjusting cap: brassSeal: polyurethaneV05 (brass):Body & adjusting cap: brassSeal: polyurethaneSeal body: acetal or brass
AlternativemodelsPre-set relief pressure (1002, 61B2,V05)Pull ring (1002)Plastic models (V05)Consult our Technical Service for use below +2°C
V 0 5 - 2 0 0 - P ˙ ˙ ˙
NPT (brass) ABSPT (brass) BPush in connection (plastic) P
1002 V05 (brass) V05 (plastic)
Nominal setting Substitute1,00 bar (15 psi) 151,35 bar (20 psi) 201,70 bar (25 psi) 252,00 bar (30 psi) 302,35 bar (35 psi) 352,70 bar (40 psi) 403,00 bar (45 psi) 453,35 bar (50 psi) 503,70 bar (55 psi) 554,00 bar (60 psi) 60
To order a 1002 unit with pull ring fitted substitute ‘8’ for ‘0’ at the last digit, e.g. 1002/BG008.
'Pop' type
61B2
Series ModelkgRange (bar)R1/4 0 ... 1,6 0,110 1002/BM000R1/4 1,6 ... 2,5 0,110 1002/BP000R1/4 6,3 ... 14 0,110 1002/BR000R1/4 0,63 ... 1,6 0,051 61B2/BM000R1/4 1,6 ... 4 0,051 61B2/BN000R1/4 2,5 ... 5 0,051 61B2/BS000R1/4 5 ... 10 0,051 61B2/BT000R1/4 10 ... 16 0,051 61B2/BU000
SubstituteThread type
Ported pressure relief valves - Pop type1002, 61B2, V05R1/4
Additional pressure settings are available up to 15,5 bar(225 psi), please contact Norgren Technical Service fordetails
Available as Cat 1 under P.E.D.as standard
Cat 4 available on request
Norgren pressure relief valves comply with categoryO(S.E.P.) and category 1 of the Pressure EquipmentDirective 97/23/EC. If categories 2, 3 or 4 products arerequired contact our Technical Services.
473
5
6
7
4
8
9
10
3
2
1
2 4 6 8 10 12 14 16 18 20 dm3/s
bar
V05-200-135A
V05-200-P45P
Ported pressure relief valves - Pop type1002, 61B2, V05
R1/4
1002
V05 (brass)
61B2
72
24
40
20
Weight: 0,11 kg
Weight: 0,05 kg
Flow characteristics
5
6
7
�
4
3
2
1
0,5 1,0 1,5 2,0 2,5 3,0 3,5 4,0 4,5 dm3/sb
ar
Port size: 1/4"
Air flow
Relie
f pre
ssur
e
1002
10
�
8
6
4
2
0,5 1,0 1,5 2,0 2,5 3,0 3,5 4,0 4,5 dm3/s
bar Port size: 1/4"
Air flow
Air flow
Relie
f pre
ssur
eRe
lief p
ress
ure
61A2, 61B2
V05
ø 23,5
52
12
14,5
1/4 "
V05 (plastic)
ø 3/8 "
ø 26
186,
5
53
Air line equipment
www.norgren.com/info/en474474
G1/4 0,01 0,02 ... 0,5 Relieving only 0,59 11-818-999G1/4 0,03 0,07 ... 4 Relieving only 0,59 11-818-100G1/4 0,05 0,4 ... 10 Relieving only 0,59 11-818-110G1/4 0,07 0,06 ... 2 Relieving only 0,90 11400-2G/PC100G1/4 0,15 0,06 ... 4 Relieving only 0,94 11400-2G/PE100G1/4 0,25 0,16 ... 7 Relieving only 1,00 11400-2G/PG100G1/4 1,00 7 ... 20 Relieving only 1,05 20AL-X2G/PK1001/4 PTF 0,10 0,04 ... 2 Relieving 0,48 R38-200-RNCA1/4 PTF 0,20 0,06 ... 4 Relieving 0,65 R38-200-RNFA1/4 PTF 0,25 0,25 ... 7 Relieving 0,65 R38-200-RNKA1/4 PTF 0,10 0,04 ... 2 Relieving 0,53 B38-200-B2CA1/4 PTF 0,20 0,07 ... 4 Relieving 0,75 B38-200-B2FA1/4 PTF 0,25 0,25 ... 7 Relieving 0,75 B38-200-B2KA
11-818 – Use downstream tee 3081-01 (Nut only, for 639-022,5 ... 6 mm panel thickness)
11400 18-001-005 18-013-011 (0 ... 4 bar) 18-003-999 18-004-99718-013-013 (0 ... 10 bar) – –
20AL-X 18-001-005 18-013-014 (0 ... 25 bar) 18-003-026 18-004-987R38 & B38 18-001-974 (Includes 18-013-913 (0 ... 6 bar) 5988-01 (Nut only) –
panel mounting nut) 18-013-909 (0 ... 10 bar)18-013-905 (0 ... 25 bar)
Accessories
11-818* compact, high precisionregulators for air gauging, laboratoryuse and precise pilot controll11400/20AL-X for high accuracy withconstant bleed, recommended aspilot control for R18/11-808/R244regulators and 40AC relief valvesR38 instrument regulators for processand petro-chemical industriiesSee also page 416 for R24 specialpurpose regulators * Not recommended for dead end use, consult ourTechnical Service for details
Technical dataMedium:Compressed air onlyMaximum inlet pressure: 25 bar (11400/20AL-X)10 bar (11-818-100)14 bar (11-818-110)8 bar (11-818-999)20 bar (R38/B38)Gauge ports:G1/8 (11400/20AL-X)1/4" NPTF (R38/B38)Ambient temperature:-20°C to +80°C -40°C to +80°C (R38/B38)0°C to +70°C (11-818)Consult our Technical Service for use below +2°C
Materials11-818, 11400 and 20AL-X:Body & bonnet: zinc alloyAdjusting knob: acetal resinElastomers: synthetic rubberR38:Body & bonnet: aluminium alloyAdjusting screw: steelElastomers: synthetic rubberB38:Element: 25µm polyethylene, 5µmceramic (manual drain only)
AlternativemodelsNon-relieving versions (R38 & B38)Contact our Technical Service fordetails
Precision pressure regulators & filter-regulators 11-818, 11400, 20AL-X, R38, B38GÊ, Ê" NPTF
* For panel mounting substitute 3 at the last digit e.g 11400-2G/PC103# For 5µm element substitute 1 at the 8th digit e.g. B38-200-B1CA** Typical mid-range variance from set pressure with 7 bar inlet at 2 dm3/s (10 bar inlet for 20AL-X2G).A Norgren oil removal filter should be fitted upstream of these units, see pages 434 and 460Can be adjusted to zero bar outlet pressure and generally to pressure in excess of those specified
11400/20AL-X11-818
R38
###
** *
B38
Port size Service kitModelkgRange (bar) *Accuracy (bar)** Operation2787-962787-982787-9711400-100/20AL11400-100/20AL11400-100/20AL11400-100/20ALR38-100RR38-101RR38-101RB38-100AB38-100AB38-100A
Bracket kitSeries Gauge Tamper-proof capPanel mounting
475
13
64
64 75
32
145
53
∅ 42
6 m
ax.
30
11400, 20AL-X R38
11-818
Bracket mounting(11400, 20AL-X)
Panel mounting(11400, 20AL-X)
Bracket mounting (R38)
Weight: 1,00 kg (11400)1,05kg (20AL-X)
Weight: 0,46 kg
* Minimum clearance required to remove bowl.
Weight: 0,59 kg
*Note: Ø 17,5 and up to 6mm max. panel thicknesswhen used with optionalpanel mounting nut reference3081-01.To order see accessoriesopposite.
*Deduct 20 mm for 20AL-X Series
Flow characteristics
�
3,99
4,00
�
1,60
1,59
1,00
0,99
� 1 � 2 � 3 � 4 � 5 dm3/s
bar
Inlet pressure (8 bar)
Air flow
Outle
t pre
ssur
e
11- 818
0,40
�
7,99
8,00
0,35
�
0,100
0,075
� 1 � 2 � 3 � 4 � 5 dm3/s
bar
Inlet pressure (10 bar)11-818
5
6
7
�
4
3
2
1
0,5 1,0 1,5 2,0 2,5 3,0 3,5 4,0 4,5 dm3/s
bar
Inlet pressure (7 bar)
Air flow
Outle
t pre
ssur
e
11400
�
3
�
2
�
1
�
1 2 3 4 5 6 7 8 9 10 dm3/s
bar
Inlet pressure (7 bar)
Air flow
Outle
t pre
ssur
e
R38/B38
Outle
t pre
ssur
e
Air flow
Standard unit
High pressure unit
Inlet pressure & bar low pressureunit
13
64
64
75
32
194 53
79
∅42
233
#
1/8" PTF
�
B38
Precision pressure regulators & filter-regulators 11-818, 11400, 20AL-X, R38, B38
GÊ, Ê" NPTF
Air line equipment
www.norgren.com/info/en482482
1/4 PTF 8* 25 Manual 0,25 ... 7 Relieving 1,40 B38-244-B2KA1/4 PTF 8* 25 Manual 0,07 ... 4 Relieving 1,40 B38-244-B2FA1/4 PTF 8* 25 Auto 0,07 ... 4 Relieving 1,60 B38-244-A2FA1/2 PTF 50** 25 Manual 0,3 ... 9 Relieving 1,40 B38-444-M2LA1/2 PTF 50** 25 Auto 0,3 ... 9 Relieving 2,10 B38-444-A2LA
1/4 PTF 8 0,04 ... 2 Relieving 0,48 R38-240-RNCA1/4 PTF 8 0,07 ... 4 Relieving 0,46 R38-240-RNFA
R38-100RR38-101R
R38
B38
Precision stainless steel regulators Pressure regulators, filter-regulators R38, B38 Ê" PTF, Ë" PTF (B38)
Precision regulators
R38-101R & B38-100S (25)R38-101R & B38-100S (25)R38-101R & B38-100S (25)2787-41 & 2787-442787-41 & 2787-44
#‡
Precision filter-regulators
* Typical flow with 7 bar inlet pressure, 6,3 bar set pressure and a droop of 1 bar
Can be adjusted to zero outlet pressure, and, generally, to pressures in excess of those specified.* Typical flow with 7 bar inlet pressure, 1 bar set pressure and a droop of 0,05 bar.
** Typical flow with 12 bar inlet pressure, 8 bar set pressure and a droop of 1 bar.
Drain kits:# Manual drain 2787-43‡ Auto drain 3000-87
* Outlet pressure can be adjusted to pressures in excessof, and less than, those specified. Do not use these units tocontrol pressures outside of the specified ranges.# 1/4" only. ‡ 1/2" only
Thread SubstitutePTF AISO RC Taper BISO G Parallel DDiaphragm Substitute
Relieving with panel nut 4Non relieving with panel nut 5
Drain SubstituteAutomatic AManual – short bowl BManual – long bowl M
Element Substitute5 µm 125 µm 2
Outlet pressure adjustment range* Substitute0,04 ... 2 C0,07 ... 4 F0,25 ... 7 K#0,50 ... 10 M0,3 ... 9 L‡
Options selectorB 3 8 - ˙ 4 ˙ - ˙ ˙ ˙ ˙
R38 and B38 Lloyds Register TypeApprovedMaterials meet NACE*recommendations (MR-0175, 2002revisiion)Suitable for marine, offshore, foodprocessing and dental applicationsR38/B38 models for precissionregulation and high flow rates* National Association of Corrosion Engineers –recognised oil-field recommendation for resistance tosulphide stress cracking common in well-head and othercorrosive environments
Technical dataMedium:Compressed air onlyMaximum inlet pressure: 17 bar (autodrain)31 bar (R38, B38 manual drain)Gauge ports:1/4 PTF (R38, B38)Ambient temperature:-40°C to +80°C (R38, B38)Consult our Technical Service for use below +2°C
MaterialsBody, bowl, bonnet & adjustingscrew: stainless steelElastomers: synthetic rubberFilter element: high densitypolyethylene (25 µm), ceramicpyrolith (5 µm) (B38)
Alternativemodels5 µm elementPressure rangesNon-relieving versionsViton elastomersContact our Technical Service for details
Anschluss Sustituir1/4 21/2 4
Modelkg Service kitPort size Flow (dm3/s)* Range (bar) Operation
Model Service kitPort size Flow (dm3/s) Element (µm) Drain Operation kgRange (bar)
483
53
64
115
248
200
6 m
ax.
285*
∅42
75
32
64
13
1/4 N.P.T.
10
8
6
4
2
10 20 30 40 50 60 70 80 90 100 dm3/s
bar Port size 1/2"
25 µm element
Air flow
Outle
t pre
ssur
e
R38 18-001-973 (includes panel nut) 18-013-913* 5988-02 (Nut only) 74630-04B38 18-001-973 (includes panel nut) 18-013-913* 5988-02 (Nut only) 74630-04
Accessories
# Other pressure ranges available – see page 486* Stainless steel items not strictly to NACE standard MR-01-75
Precision stainless steel regulators Pressure regulators, filter-regulators
R38, B38
Ê" PTF, Ë" PTF (B38)
145
53 30
∅ 42
R38 (Ê) B38 (Ê)
13
64
64 75
32
73
73
Bracket mounting (R38)Bracket mounting (B38)
75
54
75
28
388,
5
B38 (Ë)
263
268
62
162
∅42
215
#
Automatic drain
Manualdrain
Automaticdrain Manual drain
�
3
�
2
�
1
�
1 2 3 4 5 6 7 8 9 10 dm3/s
bar
R38/B38, 1/4"
B38, 1/2"
Port size 1/4"Inlet pressure 7 bar
Inlet pressure (7 bar)
Air flow
Inlet pressure (12 bar)
Outle
t pre
ssur
e
Weight: 0,48 kg
Flow characteristics
Neck mounting bracketSeries Gauge (0 ... 10 bar)# Panel mounting Plastic adjusting knob