RS
3x13,33x35 3x13,33x35
5x16,65x29
6x16
,65x2
96x
16,65
x29
6x16,65x29
5x16,65x29
6x16
,65x2
96x
16,65
x29
6x16,65x29
EL EL
EL W C.O W C.OEL
W C.O W C.O
C.O. W C.O.W C.O.
RS RS RS RS RS RS
RS RS RS RS RS RS
RS
+ 5,54+ 5,66
Hn/Hb=2,53m
+ 6,06+ 5,94
Hn/Hb=2,53m
+ 6,46+ 6,34
Hn/Hb=2,53m
+ 5,66+ 5,54
Hn/Hb=2,53m
+ 6,46+ 6,34
Hn/Hb=2,53m+4,66
+4,64
+6,49
+6,47
+7,29
+7,27
+5,46
+5,44
+ 5,54+ 5,66
+ 5,54+ 5,66
+ 5,54+ 5,66
+ 6,06+ 5,94
+ 6,06+ 5,94
+ 6,06+ 5,94
+ 6,06+ 5,94
+ 6,06+ 5,94
+ 6,06+ 5,94
+ 6,46+ 6,34
+ 6,46+ 6,34
+ 6,46+ 6,34
+ 6,46+ 6,34
+ 6,46+ 6,34
SZ3
SZ2
SZ2
SZ3
SZ3
SZ3
SZ2
SZ2
SZ2SZ
3
SZ2
SZ2
SZ3
SZ3
SZ2
SZ2
SZ2SZ2
SZ2
SZ3.1
SZ3
SZ2
SZ2.1SZ3
SW2
SW2
SW2
SW2
SW2
SW2
SW2
SW2
SW2
SW2
SW2 SW2 SW2
SW2SW2SW2SW2
SW2.1
SW2.2
SW2.3 SW2.3SW2.3
SW2.4
SW
2.4
SW3
SW3
SW3
SW3
SW3
SW3
SW3
SW3
SW
3.2
SW4 SW4 SW4 SW4
SW4SW4SW4
SW4
SW4
SW4
SW4
SW4
SW7
SW7
SW4
SW4
SW4 SW4 SW4
Ø10cm PDP=+7,74
Ø10cm PDP=+7,79
Ø16cm PDP=+7,69
92x15cmPB
21. W ODWODNIENIACH LINIOWYCH ACO - KRATA -ZABEZPIECZAJĄCA PRZED WPADANIEM LIŚCI22. GNIAZDA I OPRAWY ŚWIETLNE ZEWNĘTRZNE WG. PROJ. INSTALACJI ELEKTRYCZNEJ23. ALUMINIOWA KRATKA WENTYLACYJNA DO ZASTOSOWANIA ZEWNETRZNEGO NP. FIRMY SMAY LUB ANALOGICZNIE.24. PROFIL OGRANICZAJĄCY MODEL : TRP 140 NP. WG KOMPLETNEGO SYSTEMU ''ZINCO'' DLA DACHÓW ZIELONYCH FIRMY: ''GCL'' - LUB ANALOGICZNIE O TYCH PARAMETRACH .25. DYLATACJA WYLEWKI WARST POSADZKOWYCH WSZYSTKICH POMIESZCZEŃ W POSTACI STYROPIANU 2cm - ZGODNIE ZE SZTUKĄ BUDOWLANĄ26. W WYKOŃCZENIU WEWNĘTRZNYM MINIMALNA GRUBOŚĆ WYLEWEK - 4 CM; ZALECA SIĘ WYKONANIE ZBROJENIA PRZECIWSKURCZOWEGO27. PRZY PROWADZENIU INSTALACJI W POSADZKACH (C.O., WODA) PROWADZIĆ ZAWSZE W WARSTWIE IZOLACJI AKUSTYCZNEJ PRZY ELIMINACJI MOSTKÓW AKUSTYCZNYCH. W MIEJSCACH SKRZYŻOWAŃ INSTALACJI - GRUBOŚC ZBROJONEJ WYLEWKI MIN.4cm29. W DACHACH I STROPODACHACH STOSOWAĆ ZAWSZE IZOLACJĘ PAROCHRONNĄ POD OCIEPLENIEM30. ODWODNIENIE DACHU - KORYTO Z MEMBRANY ''EPDM'' ZG.Z OPISEM PRZEGRÓD ZEW.
PROJEKTY WYKONAWCZE OPRACOWANO ZGODNIE Z OBOWIĄZUJĄCYMI PRZEPISAMIBUDOWLANYMI, NORMAMI ORAZ INNYMI OBOWIĄZUJĄCYMI AKTAMI PRAWNYMI.POWYŻSZE PRZEPISY, NORMY ITP. OBOWIĄZUJĄ TAKŻE WYKONAWCĘ OBIEKTU KTÓRYWINIEN ZREALIZOWAĆ INWESTYCJE ZGODNIE Z PRZEPISAMI BUDOWLANYMI , NORMAMI ISZTUKĄ BUDOWLANĄ.SZCZEGÓŁOWE ZESTAWIENIE POWIERZCHNI PRZEDSTAWIONO W ZAŁĄCZNIKUOPISU TECHNICZNEGO PROJEKTU ARCHITEKTURY
UWAGI:1. WSZYSTKIE INSTALACJE ZNAJDUJĄCE SIĘ W BUDYNKU WYKONAĆ WG. PROJEKTÓW BRANŻOWYCH.2. WYMIARY PODANO W CM3. RYS.ARCHITEKTONICZNE,ZESTAWCZE ORAZ RYS. BRANŻOWE NALEŻY ZAWSZE ROZPATRYWAĆ ŁĄCZNIE3A.OŚWIETLENIE, AWARYJNE, OZNACZENIA EWAKUACJI WG. PROJEKTU ELEKTRYCZNEGO4. KONSTRUKCJA ŻELBETOWA ŚCIŚLE WG PROJ. KONSTRUKCJI5. WYSOKOŚĆ NETTO / BRUTTO KONDYGNACJI NADZIEMNYCH MIERZONA OD POZIOMU WARST WYKOŃCZENIA. WYSOKOŚĆ PODANA W METRACH.6. WYSOKOŚĆ NETTO / BRUTTO KONDYGNACJI PODZIEMNEJ ( GARAŻ ) MIERZONA OD POZIOMU WYJŚCIOWEGO PŁYTY FUNDAMENTOWEJ BEZ UWZGLĘDNIENIA SPADKÓW TJ. OD POZIOMU -3,55 = 232.20 mnpm . - WYSOKOŚĆ PODANA W METRACH.7. ŚCIANY MUROWANE MIĘDZY LOKALOWE, WEWNĄTRZ LOKALOWE, OBUDOWUJĄCE SZACHTY, WYDZIELAJĄCE POMIESZCZENIA ITP.WYPEŁNIAJĄCE POMIĘDZY KONSTRUKCJĄ ŻELBETOWĄ - WG OPISU WARSTW I RYSUNKÓW PROJ ARCHITEKTONICZNEGO ORAZ OPISU PROJ. KONSTRUKCYJNEGO ( UWAGI DOT. SPOSOBU ICH MUROWANIA I ŁĄCZENIA ZE ŚCIANAMI ŻELBETOWYMI WG.PROJ.KONSTRUKCJI)8. DYLATACJA BUDYNKU - DYLATACJĘ BUDYNKU WYKONAĆ ŚCIŚLE WG PROJEKTU KONSTRUKCYJNEGO9. OTWÓR REWIZYJNY DO PRZESTRZENI POD RAMPĄ ZJAZDOWĄ10.WIENIEC ŻELBETOWY NA ZWIEŃCZENIU ŚCIAN MUROWANYCH NA POZIOMIE ANTRESOLI ZG. Z PROJ. KONSTRUKCJI11.ŚCIANY MUROWANE NA POZIOMIE KONDYGNACJI PODZIEMNEJ / GARAŻ / MUROWAĆ PO ZAMONTOWANIU KANAŁÓW WENTYLACJI MECHANICZNEJ. ŚCIANY NA WYSOKOŚCI ~ 0,3m OD STROPU MUROWAĆ NA MIJANKĘ TWORZĄC AŻUR DO WENTYLACJI KOM.LOKATORSKICH12. ŚCIANY MUROWANE WEWNĄTRZ LOKALOWE W SYSTEMIE MULTIGIPS NALEŻY WYKONAĆ W KOMPLETNYM SYSTEMIE MULTIGIPS ORAZ ZGODNIE Z OPISEM WARSTW13. SCHODY WEWNETRZNE NA ANTRESOLĘ ORAZ BALUSTRADY NA ANTRSOLI DO INDYWIDUALNEGO OPRACOWANIA PRZEZ NABYWCĘ LOKALU MIESZKALNEGO14. SUFIT PODWIESZONY Z PŁYT G-K NA PODKONSTRUKCJI SYSTEMOWEJ, NA ODCINKU PRZEBIEGU KANALIZACJI DESZCZOWEJ SUFIT WYŁOŻYĆ OD WEWNĄTRZ MEMBRAMĄ AKUSTYCZNĄ K-FLEX FONIC GR 3 MM.15. RURA SPIRO Ø 150mm JAKO WENTYLACJA GRAWITACYJNA PRZEDSIONKÓW POŻAROWYCH, POMIESZCZEŃ POD SPOCZNIKAMI BIEGÓW Z KONDYGNACJI PODZIEMNEJ, ŚMIETNIKA ORAZ SZYBÓW WINDOWYCH16.KRATKA WENTYLACYJNA NP.PROMASEALS O WYMIARACH 93x93 mm LUB ANALOGICZNA O TYCH SAMYCH PARAMETRACH - JAKO NAWIEW POWIETRZA DO KORYTARZY PIĘTROWYCH. PRZEWIDZIEĆ DWIE KRATKI NA JEDEN NAWIEW, SUMA KRATEK DLA CAŁEGO BUDYNKU = 18 sztuk17.PUSTAK WENTYLACYJNY W SYSTEMIE PEŁNYM - PODPIĘCIE PUSTAKA ZG. Z OPISEM NA RUSUNKU RZUTÓW18.SYSTEMOWA KONSOLA STALOWA JAKO PODKONSTRUKCJA POD BLACHĘ ALUMINOWĄ NA ELEWACJACH ATTYK DACHOWYCH - KONSOLE DOBRAĆ ODPOWIEDNIO DO GRUBOŚĆI WARSTWY TERMICZNEJ NA ELEWACJI. MONTAŻ ŚCISLE WG. WYTYCZNYCH PRODUCENTA NP. FIRMY '' PREFA'' ZASTĘPCZO DOPUSZCZA SIĘ WYKONAĆ PODKONSTRUKCJĘ DREWNIANĄ. DO DECYZJI INWESTORA W PORPOZUMIENIU Z PROJEKTANTEM ARCH.19. W MIEJSCACH LOKALIZACJI KLAP DYMOWYCH ORAZ WYŁAZÓW NA DACH NALEZY ZDWOIĆ WYMIANY WIĘŹBY DACHOWEJ W CELU MONTAŻU KLAPY I WYŁAZU ZG. Z WYTYCZNYMI PRODUCENTA NP.FIRMY ''MERCOR''20. KOMINY WYKOŃCZYĆ BLACHĄ ALUMINIOWĄ ANALOGICZNĄ DO POKRYCIA DACHU. KSZTAŁTKI WENTYLACJI GRAWITACYJNEJ WYKONAĆ ŚCISLE WG. TECHNOLOGI NP: FIRMY SCHIEDEL Z UWAGĄ: NA KAŻDY KANAŁ WENTYLACJI GRAWITACYJNEJ NALEŻY PRZEWIDZIEĆ OBROTOWĄ NASADĘ KOMINOWĄ Ø 150mm TURBOWENT Tulipan Z PODSTAWĄ REDUKCYJNĄ -PKR T/25 LUB -PKR T/64 NP. FIRMY:DARCO LUB ANALOGICZNIE O TYCH SAMYCH PARAMETRACH TECHNICZNYCH. NATOMIAST NA KAŻDY KANAŁ WENTYLACJI GRAWITACYJNEJ WYKONANEJ Z RUR SPIRO NALEŻY PRZEWIDZIEĆ OBROTOWĄ NASADĘ KOMINOWĄ Ø 150mm TURBOWENT Tulipan Z PODSTAWĄ WCISKANĄ -T NP. FIRMY:DARCO LUB ANALOGICZNIE O TYCH SAMYCH PARAMETRACH .21. W ODWODNIENIACH LINIOWYCH ACO - KRATA -ZABEZPIECZAJĄCA
ELEMENTY ZESTAWCZE:O - STOLARKA OKIENNAD - DRZWI ZEWNĘTRZNE / WEW.LOKALOWEWZ - WYCIERACZKI ZEWNĘTRZNEWW - WYCIERACZKI WEWNĘTRZNEOD - ODBÓJ WEWNĘTRZNYPW - POCHWYT WEWNTRZNYBZ - BALUSTRADA ZEWNĘTRZNABR - BRAMA GARAŻOWAKD - KURTYNY DYMOWE ( GARAŻ )ZZ - ŻALUZJA ZEWNĘTRZNA ALUMINIOWAZW - ŻALUZJA WEWNĘTRZNA ALUMINIOWAWD - WPUST DACHOWYKS - KOSZ ODWADNIAJĄCY POŁAĆ DACHUNA - NAWIEWNIK OKIENNYDR - DRABINKA WYŁAZOWAW - URZĄDZENIA DŹWIGOWEKL - KLATKI SCHODOWESch - SCHODY WEWNĘTRZNES - SZAFKI INSTALACYJNE PIĘTROWESL - SZKRZYNKI NA LISTYWZD - WYŁAZ DACHOWYKO - KLAPA ODDYMIAJĄCAKW - KOMINEK WENTYLACYJNYPF - FUNDAMENT/PODPORA KANAŁÓW WENT.StD - STOPNICE DACHOWE / KOMUNIKACJA NA DACHU /KrP - KRATA PODESTOWA / KOMUNIKACJA NA DACHU /ZS - ZAPORA ŚNIEGOWA
LEGENDA:
OZNACZENIE POMIESZCZEŃ
OTWORY TECHNICZNE W STROPACH ORAZ
1 - symbol kondygnacji
PRZEGŁĘBIENIA W PŁYCIE FUNDAMENTOWEJ
SYMBOL ZESTAWCZY DRZWI
1 - symbol zestawczy drzwi2 - wymiar światła przejścia
3 - odporność pożarowa drzwi1
2 - nr mieszkania
OZNACZENIE PRZEKROJU
3 - nr pomieszczenia
2 3
SUFIT PODWIESZANY GK
/wysokość x szerokość/
OPIS PRZEGRÓD PIONOWYCH
OPIS PRZEGRÓD POZIOMYCH P1
ŚCIANY ŻELBETOWE
SZ4
ŚCIANY MUROWANE
1 - poziom wykończony
2 - poziom góry konstrukcji
SCIANY MUROWANE DZIAŁOWE
KOTY WYSOKOSCIOWE
1
2
SYMBOL ZESTAWCZY KLATEK SCHODOWYCH
SYMBOL ZESTAWCZY WINDY OSOBOWEJ
SYMBOL ZESTAWCZY STOLARKI
1 - symbol zestawu okiennego2 - wymiary w świetle otworu
3 - poziom góry parapetu 1 2 3 /wysokość x szerokość/
1 2
3
OTWORY TECHNICZNE W ŚCIANACH, BELKACH
1 - szerokość otworu, średnica otworu2 - wysokość otworu3 - PDP - poziom dolny przebicia
±0.00=206,45m n.p.m.
-0.15
1 2 3
OTWORY TECHNICZNE W ŚCIANACHi BELKACH ŻELBETOWYCH :Ø5cm - Ø15 cm wg proj. architekturyØ15cm - i większe wg proj.architektury i proj.konstrukcji
1) UKŁAD OSI KONSTRUKCYJNYCHMAJĄCY KONTYNUACJĘ PRZEZWSZYSTKIE KONDYGNACJE2) UKŁAD OSI KONSTRUKCYJNYCHJEDYNIE NA POZ.GARAŻU (KOND.-1)NIE MAJĄCE KONTYNUACJI NAKONDYGNACJE NADZIEMNE( 0,1,2,3)
POZIOM SPODU PŁYTY STROPOWEJWZGLĘDEM POZ. ''± 0.00'' BUDYNKU
1. WYSOKOŚĆ BRUTTO KONDYGNACJI2. WYSOKOŚĆ NETTO KONDYGNACJI
Hb=2,70 mHn=2,70 m
1
2
WZGLĘDEM POZ. ''± 0.00'' BUDYNKUPOZIOM SPODU BELKI
MIERZONA W METRACH
MIERZONA W METRACH
PUSTAKI WENTYLACJI GRAWITACYJNEJ /
RURY SPRIRO - WENTYLACJA GRAWITACYJNA
INSTALACJE BRANŻ SANITARNEJ WG.ODRĘBNYCH OPRACOWAŃ
PION KANALIZACJI SANITARNEJ
PION KANALIZACJI DESZCZOWEJ
PION WODY
PION C.O
OSIE KONSTRUKCYJNE:
20x30 cmPDP= +3,40m
Inwestor
Obiekt
FazaBranża Data
Tytuł rysunku Ilość rys.
Projektował Nr uprawnień Podpis
Opracował
Sprawdził
Skala
Nr rys.
RZUT PIĘTRA II - CZĘŚĆ A
RZUT PIĘTRA II - CZĘŚĆ A 1:50