Kabeldon low voltage switchgear system 2007, edition 1
47Kabeldon 2007, edition 1
Enclosures
We reserve the right to alter the design and range of our products.
3Kabeldon 2007, edition 1
Introduction
We reserve the right to alter the design and range of our products.
Page
Introduction ............................................................................................................................. 4
Fundamental technologies .................................................................................................. 5
Modern distribution technology from Kabeldon ..................................................................... 6
Kabeldon IP-system ............................................................................................................ 7
Rugged, corrosion-resistant enclosures ............................................................................... 8
Surface treatment ................................................................................................................ 9
Our products ...................................................................................................................... 10
Planning and design program ............................................................................................. 11
Reference pictures ............................................................................................................. 12
Contents – switching devices ................................................................................................ 20
Contents – enclosures .......................................................................................................... 48
Technical data ...................................................................................................................... 81
Designations in alphabetical order ......................................................................................... 84
Contents
4 Kabeldon 2007, edition 1
Introduction
We reserve the right to alter the design and range of our products.
The catalogueThe introductory pages show the mostimportant products in production and in theirproper setting. The entire range is thenpresented in two main parts: “Switchingdevices” and “Enclosures”, includingproduct data. An alphabetical list of contents can befound in the end of this catalogue. The product catalogue is also available onCD and at our webb sight. We reserve the right to alter the designand range of our products.
Introduction
We work to create safe electrical distributionvia cable networks. To achieve this, wedevelop, manufacture and market a broadrange of cable accessories, switching devicesand enclosures.Our main groups of customersare power supply company, networkcompanies, industrial companies and OEMs.
Our primary areas of expertise areelectrical connections in cable systems andcontrol of electrical field.Our own testing plant is an important aid toproduct development.
ABB in AlingsåsSweden
Our factory is situated in Alingsås about 50kilometres north-east of Gothenburg (Göteborg).
The production is automated and meetsstringent quality and environmental requirements.
ABB in Alingsås, has about 190 employees. Kabeldon products can be found in powercable networks all over the world.
Our business idea is: "we provide companies that work withelectric power with solutions which enablethem to joint and connect cables easily andsafely, and distribute electricity".
ABB ABKabeldonBox 531, SE-441 15 Alingsås, SwedenTel: +46 322 770 00Fax:+46 322 770 01www.abb.se/kabeldon
Quality and environment are amongour top-priority areas of work. They areimportant and self-evident parts of thestrategic plan. We deliberate investments in qualityand the environment are based onmodern principles. They lead to thefulfilment of ambitious goals forcompetitiveness and profitability, witha view to maximising value to thecustomer. We work continuously to improve its
processes. Important foundation stonesfor this work are:
ISO 9001 quality standard ISO 14001 environmental standard.
5Kabeldon 2007, edition 1
Introduction
We reserve the right to alter the design and range of our products.
Fundamental technologies
An insulatedconnector.
We work on the basis of four fundamentaltechnologies within which we haveaccumulated substantial expertise overmany years.
Electrical connectionsThe safe and secure transfer of electriccurrent between cable conductorsor between a cable conductorand a device requiresa good-quality electricalconnection. We test anddevelop various methods,but in most cases we usescrew technology. Thisgives us the possibility ofoffering complete solutions in line withour philosophy of easy and safe installation.
Controlling electrical fieldsAt high voltages the electrical fields mustbe controlled so that the strength of theinsulation or the surrounding material is notput at risk.Depending on the voltage level,we work with different methods, e.g.geometrical, refractive or resistive fieldcontrol. Geometrical field control isachieved with premoulded stress cones andsplicing blocks. Resistive and refractivefield control are achieved with special field-controlling materials integrated intoprefabricated termination blocks.
Flash-over duringvoltage withstand testof a cable termination.
Development of creepagecurrent resistant materialsOutdoors, cable accessoriesare exposed to majorstresses, e.g. UV radiationfrom the sun and creepagecurrents caused byprecipitation and pollution.Cable accessories areinstalled everywhere on theface of the planet: in humidtropical environments, inextreme cold or in theswirling salt mist of coastalregions. We developmaterials and designsfor outdoor use thatare only minimallyaffected by xternalfactors. In the caseof cable terminations,it's the insulators,both in the porcelainand the compositematerial. Practicalendurance tests arean important part ofour developmentwork. In addition to weather-Ometer tests,salt-mist-chamber tests and other destructivelong-term tests, the products are tested underextreme weather conditions.
Design of low voltage networksElectrical distribution in cable networks calls forsafe and rugged products to make it easier toconnect cables and to withstand external factorssuch as humidity, vibration, etc., for a long timewithout causing malfunctions.Lengthyexperience of our own manufactureof switching devicesand hot-dip galvanizedenclosures, as well asgood customerrelations, means thatwe can quickly adaptproduct developmentto suit the needs ofthe market.Cable termination illustrated with equipotential lines.
Distribution board.
Creepage currents duringsalt-mist-chamber test.
6 Kabeldon 2007, edition 1
Introduction
We reserve the right to alter the design and range of our products.
Kabeldon low-voltage distribution systemsfeature small dimensions, flexibility, safety,reliability and clear layout. The distribution board is planned with theConnect IT program, which is available free.To ensure high quality, the enclosure isassembled at the factory. The enclosure isthen fitted with the required devices. It is a simple matter to wire up thedistribution board and put it into service. Inindoor electrical rooms, the busbar systemcan also be mounted on the wall. However,we recommend an enclosed distribution boardlocated outside both for safety and to savevaluable indoor space. Among other things, the distribution boardssatisfy the requirements of:
IEC 60439 Low-voltage switchgear andcontrolgear assembliesPart 1: Type-tested and partiallytype-tested assembliesPart 5: Particalar requirementsfor assemblies for powerdistribution in public networks.
IEC 60947 Low-voltage switchgear andcontrolgearPart 1: General rulesPart 3: Switches, disconnectors,switch-disconnectors and fusecombination units
The following list mentions some typicalapplications for Kabeldon IP-system:
Utilities• electricity distribution in low voltage networks• substations and enclosuresRoads• street and road lighting; traffic lights
Buildings• distribution boards for hospitals, hotels,
food shops, offices, etc.
Ports and airports• electricity supply for boats and ships• electricity supply for aircraft on the ground
Sports installations• floodlighting for football and sports stadiums• lighting for jogging tracks, control panels for
ski-lifts, etc.
Construction sites• temporary electricity supply• central electric heating• distribution boards for cranes and other
equipment
Temporary activities• electricity supply for street markets, travelling
exhibitions, circuses, fairgrounds, etc.
Communication systems• enclosures for fibre-optic networks• enclosures for antenna systems and cable TV• terminal strips for telephony
Industry/agriculture• distribution boards to supply standby power
to various types of industrial firms
IncomingFuse-switcheswith independentmanual operation
OutgoingFuse-switchdisconnector
Modern distribution technology
Spare spaceMeasuring unitVoltage fuses andcurrent transformers,sealable
7Kabeldon 2007, edition 1
Introduction
We reserve the right to alter the design and range of our products.
Kabeldon IP-system
Kabeldon IP-system.
The system consists of a unique, screen-protected busbar system which is combinedwith a broad range of switching devices andconnections. Features of the Kabeldon IP-system areits simplicity and reliability. These are themost important factors when you want toachieve low operating costs and high deli-very reliability in a distribution system.
Busbars of continuously-extruded alumi-nium sections, insulated with a layer ofpolyamid.
The busbar has a screen-protectedcontact slot. This ensures safetyregardless of where on the busbar theswitching device is placed.
Switching devices are available for bothdiazed and blade fuses.
The switching devices can be arranged inany order, regardless of rated current.
All parts have a high degree of protectionand are safe.
Switching devices 100-1600 A.
It is easy to add newswitching devices toexisting distributionboards.
Switching devices aremounted on andconnected to thebusbar system in thesame operation.
Switching devicescan be connected whenthe system is live.
Always voltage-free (“dead”) whenchanging fuses.
Busbars are available with rated currentsfrom 400 to 1600 A.
Switching devices, connectors andbusbars combine to form a modularsystem. Each module is 12.5 mm. Themodular system makes planning easier.
The compact design of the switchingdevices makes them suitable for use inmany different types of distribution boards.
All switching devices have a utilisationcategory so that they can be used in cabledistribution cabinets, substations andother distribution boards.
8 Kabeldon 2007, edition 1
Introduction
We reserve the right to alter the design and range of our products.
Powder coated enclosure type KSIK.
Hot-dip galvanized enclosure type CDC.
Hot-dip galvanized enclosure type SDC.
Rugged, corrosion-resistant enclosures
* In according to ISO 12944-2C1 = Heated, dry rooms.C2 = Small amounts of humidity may occur.
Since the 1920s, we have been manufacturingcable distribution cabinets. The latest generation of cable distributioncabinets was developed based on our longexperience of systems for demandingenvironments. At the same time, they satisfycurrent requirements for long life with undi-minished safety and low operating andmaintenance costs. In Scandinavia, where snow is commonlycleared with snowploughs and where thetemperature in winter can drop to -25 °C orlower, stability and surface treatment mustbe of the highest class. Resistance toexternal impact tests according to standardIEC 60439-5. In addition, good ventilation isessential to disperse heat during the summerand to eliminate condensation.
CDC - a versatile range ofenclosures with a timeless designCDC was developed in close collaboration withusers. The enclosures satisfy the demands ofthe network companies and the contractors forsimplicity and flexibility. They can also be usedfor broadband systems using fibre-opticcables, for telephone installations and cableTV.A number of practical functions make theinstaller’s work easier.
SDC - versatile enclosure withextra depthThis enclosure is designed for both indoorand outdoor distribution boards. SDC is hot-dip galvanized and has adesign that harmonises well with the CDCseries, so that the two can be used together.There is also a variant with a top section formeters or other equipment.
KSIK - powder coatedSuitable enclosure for indoor distributionboards in environment classes C
1* and C
2*
e.g. in industry, buildings, sports halls,warehouses. KSIK has special entries in the side, foreasier assembly with through busbarsystems.
9Kabeldon 2007, edition 1
Introduction
We reserve the right to alter the design and range of our products.
Surface treatment
Six protective coats for outstanding corrosion protection of steel in the ground
CDC and SDC enclosures are made ofsheet steel and are protected againstcorrosion by hot-dip galvanizing accordingto ISO 1461. For parts that are buried in theground, the corrosion protection has beenreinforced with a polymer coating. To makesure that the polymer coat adheres to thehot-dip galvanized surface, it has undergonezinc/manganese phosphating. The above treatment gives excellentprotection against corrosion, so that the lifeof the enclosures is long in the mostcommonly occurring environments foroutdoor enclosures.
Zn/Mn-phosphating
Steel
Hot-dip galvanizing/Zn (active protection)
Hot-dip galvanizing/Zn (active protection)
Polymer coat (passive protection)
Zn/Mn-phosphating
Polymer coat (passive protection)
10 Kabeldon 2007, edition 1
Introduction
We reserve the right to alter the design and range of our products.
Our products
Enclosures for various fields of application
Cable distribution cabinets with switchingdevices and busbar systems.
11Kabeldon 2007, edition 1
Introduction
We reserve the right to alter the design and range of our products.
Planning and design program
Connect IT planning programThe Connect IT planning program is aWindows®-based planning program for cabledistribution cabinets, service distributionboards and other applications based on therange of switching devices, busbar systemsand enclosures. Connect IT makes it easy to design anelectrical distribution board and to obtaindetails of its components as follows:
Enclosures with accessoriesBusbar systemSwitching devices and connectionOwn hardware added, e.g. fuses
Connect IT also generates information forordering, planning and documentation.
A single-line diagram, to whichaddresses, cable data and other detailscan be added.A front panel sketch, which can be usedas a basis for component mounting.
Connect IT runs in a 32-bit environment andtherefore requires Windows® 98/2000/XPor NT. Connect IT offers great scope to freelycreate any desired combination of switchingdevices and enclosures. The work is donequickly and simply, with the aid of a pictureand text. A customer database can be linked to theprogram, so that it is well-suited to be usedfor tendering.
Connect IT is also suitable for use whenchoosing an upgrade kit for older cabledistribution cabinets, or when planning abusbar system without enclosure, e.g. forinstallation in electrical operating areas.
Connect IT will be loaded from ourhome page: www.abb.se/kabeldon
Contact us for further information and toplace your order!
Front panel sketch of complete cabinet created in Connect IT.
12 Kabeldon 2007, edition 1
Introduction
We reserve the right to alter the design and range of our products.
Reference picturesSurface treatment and assembling
Automatic hot-dip galvanizing plant.
Powder coating of foundation parts.
Sewage treatment works for outgoingwaste water from surface treatment.
Fully-automatic plant for thepressing, punching and bendingof metal plate.
Assembling of enclosures.
Assembling of switching devices withmodern technology.
Assembling of distributionboards adapted to customerspecific requirements.
Automatic pre-treatment ofenclosures before powdercoating.
13Kabeldon 2007, edition 1
Introduction
We reserve the right to alter the design and range of our products.
Reference pictures
Kabeldon cable distribution cabinetssupply parked refrigerated containers inthe Port of Gothenburg, Sweden.
Cable distribution cabinet forelectricity supply and cable TVin a new residential area inÄngelholm, Sweden.
Cable distribution cabinet atconstruction of double-tracked railwaythrough Hallandsåsen, Sweden.
At Frakkastigeur street, Reykjavik, Iceland.
Kabeldon cable distribution cabinet atIcelands south-west, geothermal warmwater power which delivers warm waterfrom Iceland's natural hot springs viapipes to Reykjavik.
14 Kabeldon 2007, edition 1
Introduction
We reserve the right to alter the design and range of our products.
CDCM for feeding and measuring of automaticequipment to traffic signals in Malmö, Sweden.
SDCM is used for streetlighting nearKalmar cathedral, Sweden.
Cable distribution cabinets for electrifictionof signal processing equipment at Kalmar C,Sweden.
Reference pictures
Cable distribution cabinetsat marina in Skälderviken,Ängelholm, Sweden.
15Kabeldon 2007, edition 1
Introduction
We reserve the right to alter the design and range of our products.
Reference pictures
The Öresund Bridge, Sweden-Denmark:CDC cable distribution cabinets to supplya lantern on a work of art.
Cable distribution cabinet on an oil drilling riggat Stavanger, Norway.
Cable distribution cabinet to supply an light art workof Lars Hellsten at Nybro, Sweden.
CDC as a lighting distribution board, Riga, Latvia
Junction box installed in Bristol, England. This replacesthe conventional underground junction box.
Pole-mounted cable distributioncabinet with cable duct to the ground.
16 Kabeldon 2007, edition 1
Introduction
We reserve the right to alter the design and range of our products.
Distribution board to connect wind powerstations, Halmstad, Sweden.
Cable distribution cabinet for street lightinginstallated outside the Governor’s Palace inAlexandria, Egypt.
Distribution board to supply the pharmaceuticalcompany, Cara Partners Pharmacy Ind., Cork,Ireland.
Reference pictures
Bromma airport at Stockholm, Sweden. Distributionboard to supply the airoplain on the ground torefuelling, service etc.
Bromma airport at Stockholm. Distribution board tosupply the aircraft on the ground for refuelling,service etc.
Distribution board at taxi zone, at Ängelholm'sairport.
17Kabeldon 2007, edition 1
Introduction
We reserve the right to alter the design and range of our products.
Kabeldon low-voltage products mounted directlyon a wall in a substation in Trondheim, Norway.Contact us for further information about thenecessary material, price, delivery, etc.
We manufacture standardised servicedistribution boards for McDonald’s all overSweden. The McDonald’s distribution boardat Vårgårda, Sweden.
Kabeldon IP-system used for feeding and control of thePromenade’s modern lamp posts in Blackpool, England.
Cable distribution cabinet installed asa service distribution board for atelecommuni-cations installation, Sweden.
Reference pictures
18 Kabeldon 2007, edition 1
Introduction
We reserve the right to alter the design and range of our products.
Reference pictures
Reconstruction of a listed building and a new lowvoltage switchgear at an old market trade, Uddevalla,Sweden.
Distribution board in the port of Gothenburg(Göteborgs Hamn) Sweden.
Safe switchgear with busbars and devices,Kabeldon IP-system.
Distribution board for low EMF withKabeldon busbars and devices, Sweden.
Distribution board with Kabeldonswitching devices, Vietnam.
19Kabeldon 2007, edition 1
Introduction
We reserve the right to alter the design and range of our products.
Reference pictures
Cable distribution cabinetsused as electricity and fibreoptic networks.
Temporary service distribution boards for the”Eurovision Song Contest 2003” in Riga, Latvia.
In Jönköping, Sweden, a CDCenclosure has been used for thewater supply for the trade fair site.
Kabeldon enclosure used as controllequipment for adjustment of circlesillumination at the entrance to Kalmar(E22), Sweden. The controll equipmentis manufactured by Vägfors.
Junction box installed in Bristol, England.
20
Switching devices
Kabeldon 2007, edition 1We reserve the right to alter the design and range of our products.
Contents - switching devices
Standard for switching devices ............................................................................................. 21
New generation Kabeldon IP-system..................................................................................... 22
Switching devices with dependent manual operation ............................................................. 23
Switching devices with independent manual operation .......................................................... 28
Connectors ........................................................................................................................... 31
Busbar systems with accessories ......................................................................................... 32
General accessories for OEM ............................................................................................... 37
Dimension drawings .............................................................................................................. 43
Page
21Kabeldon 2007, edition 1
Switching devices
We reserve the right to alter the design and range of our products.
Standard for switching devices
Utilization categoryThe utilization category for the switchingdevices is stated in the technical data foreach product.
Rated diversity factorFor switching devices mounted in an cabledistribution cabinet, distribution board ordirectly on the wall; the rated current must bereduced where there are parallel current paths.
Rated current for phase- and neutralbusbars.The stated rated current refers to the highestpermitted current in any section of the busbar.
Voltage testingAll of the devices have apertures designed forvoltage testers conforming toIEC 61243-3.
ConnectorsAll switching devices come complete withterminal connectors for both Cu and Alconductors. Connectors for Al conductorshave been tested to Swedish StandardSEN 24 15 10 equivalent to VDE 0220/1 orIEC 61238-1. The tightening torque depends on thecross-sectional area of the cable and isstated in the installation instructions andon a label on the inside of the enclosure.
Conductor area Tightening torque
2.5-35 mm2 15 Nm50-95 mm2 20 Nm120-300 mm2 35 Nm
Connection to the busbar 15 Nm
Area rangeThe stated area range refers to connectionwith a stranded or solid conductor. Whenconnecting a flexible conductor, reduce themax. area by one area’s step.
Parallel conductorsThe connectable area for parallel conductorsis determined by dividing the maximum areaby the number of parallel conductors andreducing by one more area step.Ex: max cable connection 300 mm2,300/2 ⇒ 150 go down by a step ⇒ 120.
Modular systemThe dimensions of all items that can beconnected to the busbar system are basedon a module (one module M = 12.5 mm).This makes it easy to calculate the spacerequired by a particular distribution boardand then to choose a suitable enclosure.
Number of Rated diversitymain circuits factor
2 and 3 0.94 and 5 0.86 to 9 0.7
10 and above 0.6
22
Switching devices
Kabeldon 2007, edition 1We reserve the right to alter the design and range of our products.
New design signifies with among other things:• Common design for easier managing• Easy to grip, horizontal handle• New profile bolts that guarantee right
connection to the busbars• Bladefuses in all of the switching devices• Easily manoeuvred fuse lock simplify
exchange of the fuse• Sliding connection clamp means simpler
connection. Connecting clamp is alwaysenclosed
• Lower torque during connection of cables• Possibility to sealing
An additional advantage withKabeldon IP-system is compatible withthe earlier generation.
The new generationKabeldon IP-system
23Kabeldon 2007, edition 1
Switching devices
We reserve the right to alter the design and range of our products.
Switching devices withdependent manualoperation
••••• System always dead forreplacing fuses
••••• Accepts Al and Cu conductors••••• Mounts and connects in a
single operation••••• Triple-pole breaking
Designation ID No. Rated Qty Weight data a
kit kg/kit
JDD 000 2CGX0 63190375 6.1 kA/1 s 1 2.2KSBD 00 2CGX0 63190109 – 3 0.1KN 00 2CGX0 63190105 160 A 3 0.1
To be ordered separately:
JDD 000Earthing device.
SLD 000Fuse-switch disconnector.• AC-23B in according
to IEC 60947-3• 3 modules or
38 mm width• Fuse NH 000 or C00• Sealing possibility
Designation ID No. Degree of Qty Rated Cable Qty Weightprotection modules data connection a
Al/Cu kitmm2 kg/kit
SLD 000 2CGX0 63050106 IP2X* 3 400 V, 100 A 2.5-95** 1 1.7
KSBD 00Blocking device.
* IP1X with open device, depending on design of fuse.** Max area refers to connection with a stranded or solid conductor.
KN 00Linking knife
24
Switching devices
Kabeldon 2007, edition 1We reserve the right to alter the design and range of our products.
Switching devices withdependent manualoperation
••••• System always dead forreplacing fuses
••••• Accepts Al and Cu conductors••••• Mounts and connects in a
single operation••••• Triple-pole breaking
* IP1X with open device, depending on design of fuse.** Max area refers to connection with a stranded or solid conductor.
Designation ID No. Degree of Qty Rated Cable Qty Weightprotection modules data connection a
Al/Cu kitmm2 kg each
SLD 00 2CGX0 63050107 IP2X* 4 400 V, 160 A 2.5-95** 1 1.8
Designation ID No. Degree of Qty Rated Qty Weightprotection modules data a
kit kg each
JDD 00 2CGX0 63190376 – 4 6.1 kA/1 s 1 2.3KSBD 00 2CGX0 63190109 – – – 3 0.1KN 00 2CGX0 63190105 – – 160 A 3 0.1
To be ordered separately:
SLD 00Fuse-switch disconnector.• AC-23B in according
to IEC 60947-3• 4 modules or
50 mm width• Fuse NH 00• Sealing possibility
KSBD 00Blocking device.
KN 00Linking knife
JDD 00Earthing device.
25Kabeldon 2007, edition 1
Switching devices
We reserve the right to alter the design and range of our products.
Switching devices withdependent manualoperation
••••• System always dead forreplacing fuses
••••• Accepts Al and Cu conductors••••• Mounts and connects in a
single operation••••• Triple-pole breaking
JDD 1Earthing device forSLD 1.
SLD 1Fuse-switch disconnector.• AC-23B in according
to IEC 60947-3• 10 modules or
120 mm width• Fuse NH 1
(max width 42 mm)
* 250 A with fuse, 400 A with linking knife.** Max. area refers to connection with a stranded or solid conductor.
KSBD 2Blocking device.
Designation ID No. Rated Qty Weightdata a kit kg each
JDD 1 2CGX0 63190377 16.6 kA/0.5 s 1 2.4KSBD 2 2CGX0 63190110 – 3 0.1KN 1 2CGX0 53190345 400 A 1 0.2
Designation ID No. Degree of Qty Rated Cable Weightprotection modules data connection
Al/Cumm2 kg each
SLD 1 2CGX0 63050108 IP2X 10 400 V, 250 A* 50-300** 4.3
To be ordered separately:
KN 13-pack linking knife kit.
26
Switching devices
Kabeldon 2007, edition 1We reserve the right to alter the design and range of our products.
Switching devices withdependent manualoperation
••••• System always dead forreplacing fuses
••••• Accepts Al and Cu conductors••••• Mounts and connects in a
single operation••••• Triple-pole breaking
* 400 A with fuse, 600 A with linking knife.** Max. area refers to connection with a stranded or solid conductor.
KSBD 2Blocking device.
Designation ID-nr Degree of Qty Rated Cable Weightprotection modules data connection
Al/Cumm2 kg each
SLD 2 2CGX0 63050109 IP2X 12 400 V, 400 A* 50-300** 4.6
Beteckning ID-nr Qty Rated Weighta kit data kg each
JDD 2 2CGX0 63190378 1 16.6 kA/0.5 s 2.5PHD 2 2CGX0 63090024 1 400 V, 2 x 400 A 1.5PHD 2 SDC 2CGX0 63090023 1 400 V, 2 x 400 A 1.5KSBD 2 2CGX0 63190110 3 – 0.1KNB 2 2CGX0 53190321 3 630 A 0.2
Beställes separat:
PHD 2Parallel handle forparallel operation oftwo SLD 2 inenclosures CDC.
PHD 2 SDCParallel handle forparallel operation oftwo SLD 2 in enclosuresSDC.
KNB 2Linking knife.
SLD 2Fuse-switch disconnector.• AC-23B in according
to IEC 60947-3• 12 modules or
150 mm width• Fuse NH 2• Possibility for parallel
operation
JDD 2Earthing device.
27Kabeldon 2007, edition 1
Switching devices
We reserve the right to alter the design and range of our products.
Switching devices withdependent manualoperation
FD 3300Disconnector.
KFBDBlocking device.
Disconnectors are intended for single-polebreaking. By using the linking knives betweenadjacent disconnectors, the busbar systemcan be made dead without cutting off thecurrent from the incoming cable passing through.
••••• Accepts Al and Cu conductors••••• By removing the linking
knives, the system can bemade dead withoutdisconnecting the incomingcable.
••••• Single-pole breaking
** Max. area refers to connection with a stranded or solid conductor.
Designation ID No. Degree of Qty Rated Cable Weightprotection modules data connection
Al/Cumm2 kg each
FD 3300 2CGX0 63030032 IP2X 7 500 V, 400 A 50-300* 2.6
Designation ID No. Weightkg each
KFBD 2CGX0 63190112 0.1
To be ordered separately:
28
Switching devices
Kabeldon 2007, edition 1We reserve the right to alter the design and range of our products.
Switching devices withindependent manualoperation
SEKOB 250, 400Switch-fuse with breaking on bothsides of the fuse.
SEKO 160Switch-fuse with breaking onboth sides of the fuse.
PH-S 250/400Parallel handle forSEKOB 250/400.
* Max. area refers to connection with a stranded or solid conductor.
••••• Fuse replacement with deadsystem
••••• Protection IP2X••••• Handle can be locked in the
off position••••• Sealable cover over fuses for
accidental contact protection••••• Triple-pole breaking
FH-S 250/400Interlocking mechanismfor SEKOB 250/400.
Designation ID No. Qty Rated Cable Fits in Suitable Weightmodules current connection enclosure fuse size
A Al/Cumm2 kg each
SEKO 160 2CGX0 63050051 12 160 50-300* KSIK, CDC, SDC 00 5SEKOB 250 2CGX0 63050080 17 250 50-300* KSIK, SDC 0, 1 10SEKOB 400 2CGX0 63050081 17 355 50-300* KSIK, SDC 0, 1, 2 11
To be ordered separately:Designation ID No. Qty Rated Weight
per pack data kg each
FH-S 250/400 2CGX0 43050395 1 – 0.6PH-S 250/400 2CGX0 43050393 1 – 0.7KN 00 2CGX0 63190105 3 500 V, 160 A 0.1KNB 2 2CGX0 53190321 3 500 V, 630 A 0.2
Switch Select
160 A SEKO 160 + KN 00250 A SEKOB 250 + KNB 0400 A SEKOB 400 + KNB 2 KN 00
Linking knife.KNB 2Linking knife.
29Kabeldon 2007, edition 1
Switching devices
We reserve the right to alter the design and range of our products.
SLOB 630, 800Section switch-fuse with breaking on both sides ofthe fuse.
LBOC 630 - 1600Section switch without fuse.
To mount SLOB 800, LBOC 800 and 1600the busbar system must be split.For switching devices with rated current800 A and 1600 A the busbar ends must betreated.
Switching deviceswith independent manualoperation
Designation ID No. Qty Rated Fits in Suitable Weightmodules current enclosure fuse size
A kg each
SLOB 400 2CGX0 63050097 17 400 KSIK, SDC 0-2 8.6SLOB 630 2CGX0 63050101 30 630 KSIK, SDC 3 15SLOB 800 2CGX0 63050102 27 800 KSIK, SDC 3 15LBOC 630 2CGX0 63050103 27 630 KSIK, SDC – 8LBOC 800 2CGX0 63050104 25 800 KSIK, SDC – 8LBOC 1600 2CGX0 63050105 34 1600 KSIK, SDC – 18
••••• Fuse replacement with deadsystem
••••• Protection IP2X••••• Handle can be locked in the
off position••••• Sealable cover over fuses for
accidental contact protection••••• Triple-pole breaking
30
Switching devices
Kabeldon 2007, edition 1We reserve the right to alter the design and range of our products.
AS-T3Adapter for circuit-breaker typeTmax T3 for 250 A from ABB Sace.– Degree of protection IP2X.– Allows circuit-breakers to be mounted on
a livebusbar system.– Fits all Kabeldon busbars.– Fits Kabeldon enclosures.– Meets the requirements of IEC 60947-1.
Adapter plates for module casecircuit breakers (MCCB)type T3 and T5 from ABB SACE
••••• Fits all Kabeldon phasebusbars
••••• Triple-pole breaking
Tmax T3 from ABB SACEmounted on adapter plateAS-T3.
Designation ID No. Qty Rated Cable Dimensions Weightmodules data connection Height Width Depth*
Al/Cumm2 mm kg/unit
AS-T3 2CGX0 63050093 9 690 V, 250 A 300 325 105 125 2.1KLAP T5 630 2CGX0 53050209 12 400 V, 570 A – 395 150 125 3.0
KLAP T5 630Adapter plate for plug-in socket tocircuit-breaker Tmax T5 630 for 570 Afrom ABB Sace.– Fits all Kabeldon busbars.– Meets the requirements of IEC 60947-1.
* The depth is only applied to adapter plate.
Tmax T5 from ABB SACEand plug-in socket aremounted on adapterKLAP T5 630.
Note. circuit-breaker is not included.
Note. circuit-breaker and plug-insocket is not included.
31Kabeldon 2007, edition 1
Switching devices
We reserve the right to alter the design and range of our products.
ADNSpacer for PEN bar,used with AD 300.
AD 2150Insulated connectorfor parallel conductors.
ADC 25Non-insulated connector.May only be used withnon-protected busbars.
AD 70Non-insulated connector.May only be used withnon-protected busbars.
Connectors
KSBH 300Cover for disconnectedcable, for protectionagainst accidental contact,with ADI 300 or AD 2150.
Switching devices and connectors mustbe tightened to a recommended torque.
** ADB 3M to be supplemented with three AD 300.*** Three-phase connection, 6-9 modules.
AD 350Non-insulated connectorfor connecting threeseparate conductors,each max 50 mm² Al/Cu.May only be used withnon-protected busbars.
ADB 3MInsulated connectorfor compact fitting ofAD 300 for 3 phases.
Designation ID No. Qty Width Rated Degree of Cable Qty Weightmodules data protection connection per
Al/Cu packmm mm2 kg each
ADC 25 2CGX0 63030233 – 14 500 V, 63 A IP00 1,5-25 50 0.1AD 70 2CGX0 63030038 – 23 500 V, 200 A IP00 6-95 50 0.1ADO 240 2CGX0 63030263 3 30 400 V, 400 A IP00 120-240 1 0.25AD 350 2CGX0 63030262 – 38 690 V, 400 A IP2X 3 x 6-50 25 0.2ADB 3M* 2CGX0 63030258 3 38 500 V, 500 A IP2X – 1 0.7AD 95 2CGX0 79000011 2 25 500 V, 200 A IP2X 6-95 3 0.1AD 2150 2CGX0 63030037 3 38 500 V, 400 A IP2X 35-2//150 3 0.2AD 300** 2CGX0 63030195 3 38 500 V, 630 A IP2X 50-300 3 0.2KSBH 300 2CGX0 63190111 – 46 – – – 3 0.1ADN 2CGX0 63030231 – 37 500 V, 500 A – – 1 0.3
ADO 240Non-insulated connector120-240 mm².May only be used withnon-protected busbars.
AD 300Insulated connector.
AD 95Insulated connector.
32
Switching devices
Kabeldon 2007, edition 1We reserve the right to alter the design and range of our products.
Busbar systems with accessoriesWith accidental contact protection, IP2X
KSFS 420-473400 A.
KSFS 640 A-698 A630 A.
KSFS 1083-101261000 A.
KSFS 1683-161811600 A.
Rated current for busbar systems. The stated rated current is the maximumcurrent in any part of the busbar.
Designation ID No. Qty Rated Suitable Length Weightmodules current busbar support
KSST 36 KSST 316KSST 316/23
A KSST 316/100 mm kg/m
KSFS 420 2CGX0 43320260 20 400 x x 284 0.6KSFS 440 2CGX0 43320261 40 400 x x 534 0.6KSFS 443 2CGX0 43320037 43 400 x x 569 0.6KSFS 448 2CGX0 43320258 48 400 x x 636 0.6KSFS 460 2CGX0 43320262 60 400 x x 784 0.6KSFS 463 2CGX0 43320038 63 400 x x 809 0.6KSFS 473 2CGX0 43320264 73 400 x x 950 0.6KSFS 640 A 2CGX0 43320363 40 630 x x 534 0.9KSFS 643 A 2CGX0 43320367 43 630 x x 569 0.9KSFS 648 A 2CGX0 43320365 48 630 x x 636 0.9KSFS 660 A 2CGX0 43320364 60 630 x x 784 0.9KSFS 663 A 2CGX0 43320368 63 630 x x 809 0.9KSFS 673 A 2CGX0 43320369 73 630 x x 950 0.9KSFS 698 A 2CGX0 43320366 98 630 x x 1264 0.9KSFS 1083 2CGX0 43320145 83 1000 – x 1079 1.6KSFS 1098 2CGX0 43320156 98 1000 – x 1264 1.6KSFS 10126 2CGX0 43320146 126 1000 – x 1600 1.6KSFS 1683 2CGX0 43320152 83 1600 – x 1079 3.0KSFS 1698 2CGX0 43320158 98 1600 – x 1264 3.0KSFS 16126 2CGX0 43320153 126 1600 – x 1600 3.0KSFS 16149 2CGX0 43320154 149 1600 – x 1890 3.0KSFS 16181 2CGX0 43320155 181 1600 – x 2300 3.0
33Kabeldon 2007, edition 1
Switching devices
We reserve the right to alter the design and range of our products.
Busbar systems with accessoriesWithout protection against accidentalcontact (type PEN, PE and N), IP00
KSNS 417-498400 A.
KSNS 1083-101811000 A.
* KSNS 440 is used with SDC 48 and CDC 40.
Designation ID No. Qty Rated Length Weightmodules current
A mm kg/m
KSNS 417 2CGX0 43320059 17 400 209 0.6KSNS 420 2CGX0 43320192 20 400 333 0.6KSNS 440* 2CGX0 43320193 40 400 585 0.6KSNS 443 2CGX0 43320052 43 400 569 0.6KSNS 460 2CGX0 43320194 60 400 835 0.6KSNS 463 2CGX0 43320053 63 400 809 0.6KSNS 473 2CGX0 43320196 73 400 900 0.6KSNS 498 2CGX0 43320190 98 400 1214 0.6KSNS 498 KSIK 2CGX0 43320195 98 400 1266 0.6KSNS 1083 2CGX0 43320162 83 1000 1079 1.6KSNS 1098 2CGX0 43320169 98 1000 1212 1.6KSNS 1098 KSIK 2CGX0 43320343 98 1000 1264 1.6KSNS 10126 2CGX0 43320163 126 1000 1600 1.6KSNS 10149 2CGX0 43320164 149 1000 1890 1.6KSNS 10181 2CGX0 43320165 181 1000 2300 1.6
34
Switching devices
Kabeldon 2007, edition 1We reserve the right to alter the design and range of our products.
Busbar systems with accessoriesBusbar supports
KSST 36Support for 400 A and630 A busbars. Fixinghole pitch 85 mm.To split busbar systemsfor metering with currenttransformers, etc.
KSST 316, 316/23,316/100Support for 400 A,630 A, 1000 A and1600 A busbars.Primarily in SDC.
KSST 36-CDCSupport for 400 A and630 A phase bars. Used in split andshortened busbarsystems in CDCenclosures. Fixing holepitch 85 mm.
KLKB-S 630, 1200Bar bridge to interconnectbusbar systems in twoenclosures. May only beinstalled on dead busbar.
Designation ID No. Rated Free space Qty Suitable Weightcurrent behind the bars modules enclosures
A mm kg each
KSST 36 2CGX0 53320186 – 11 2 all 0.1KSST 36-CDC 2CGX0 53320187 – 15 2 CDC 0.3KSST 316 2CGX0 53320104 – 9 2 all 0.5KSST 316/23 2CGX0 53320106 – 23 2 all 0.8KSST 316/100 2CGX0 53320105 – 100 2 SDC 1.1KSST-CDC 2CGX0 53320231 – 15 – CDC 0.4KLKB-S 630 2CGX0 51190106 630 – – all 3.4KLKB-S 1200 2CGX0 51190107 1200 – – SDC 6.6
KSST-CDCSupport for 400 and630 A busbars whenmounting in enclosuretype CDC.
The kit containstwo completesupports and 4screws.
35Kabeldon 2007, edition 1
Switching devices
We reserve the right to alter the design and range of our products.
Busbar system with accessoriesMiddle support for 400-1600 Abusbars
MSB 316/23Middle support fits to KSST 316/23.Made from non-magnetic stainlesssteel.
MSB 316Middle support to fit KSST 316.Made from non-magneticstainless steel.
MSB 316/100Middle support fits to KSST 316/100.Made from non-magnetic stainlesssteel.
The maximum distance between twobusbars is 1 metre to meet short-circuitstrength according to the technical data onpage 81. If more than 1 metre, a middlesupport must be used at a suitable point.
Designation ID No. Free space Qty Weightbehind the busbars modules
mm kg each
MSB 316 2CGX0 53320201 9 1 0.5MSB 316/23 2CGX0 53320202 23 1 0.8MSB 316/100 2CGX0 53320203 100 1 1.2
36
Switching devices
Kabeldon 2007, edition 1We reserve the right to alter the design and range of our products.
Busbar systems with accessories5-wire kit
••••• Simple to fit when upgradingan existing cabinet
Upgrading kit for 1000 Abusbars. Please contact your supplierfor further information.
Designation ID No. Fits enclosure Rated current Length WeightA mm kg each
C20-TNS 2CGX0 53310613 CDC 20 400 333 0.6C40-TNS 2CGX0 53310614 CDC 40 400 583 0.7C60-TNS 2CGX0 53310615 CDC 60 400 833 0.9S48-TNS 2CGX0 53320165 SDC 48 400 584 0.9S73-TNS 2CGX0 53320180 SDC 73 400 898 1.0S98-TNS 2CGX0 53320166 SDC 98 400 1212 1.2
Kit for conversion to five-wiresystem, TN-S or TN-C-S. The kit includes a 400 Anon-protected busbar.
37Kabeldon 2007, edition 1
Switching devices
We reserve the right to alter the design and range of our products.
AB 800-53, AB 1200-53,AB 1200-70For connection to the back of thebusbar; fits 1000 A and 1600 A bar.The kit includes:• Plastic cover• Thread insert, M12/M16 length
53 respectively 70 mm.• Connecting washer• Flat washer, Ø 36 mm• Compression washer, Ø 29 mm• Nut, M12
General accessories for OEM
RKMB 900Tool kit for AB 800/1200.The kit contains the necessarytools for:• Stripping phase busbar
insulation• Drilling and tapping holes• Fitting the thread insert
The kit does notinclude the cablelug.
Designation ID No. Qty Rated Diameter Qty Weightmodules data Ø mm per pack kg each
AB 800-53 2CGX0 53030500 – 500 V, 800 A 26 1 0.1AB 1200-53 2CGX0 53030501 – 500 V, 1200 A 37 1 0.1AB 1200-70 2CGX0 53030502 – 500 V, 1200 A 37 1 0.1ADR M8* 2CGX0 63030239 2 500 V, 630 A – 50 0.1ADR M10* 2CGX0 63030240 2 500 V, 630 A – 50 0.1ADR H12 2CGX0 63030259 2 500 V, 630 A – 50 0.1RKMB 900 2CGX0 53030503 – – – 1 1.6KBS 20 2CGX0 43311123 4 Ik 23.7 kA – 1 1.1
KBS 20Kit for earthing busbars. Fitsto busbar systems type KSFS400 A -1600 A.
The ball headed bolt istested for short-circuit currentIK 23,7 kA according tostandards DIN 48088 andIEC 61230.
The kit consists of 3 ballheaded bolts Ø 20 mm,connection unit for mountingto the busbars and aremovable protective cover.
ADR M8/M10For connection to the front ofthe busbar, with M8 or M10thread.
ADR H12For connection to the frontof the busbar, with Ø12 hole.
For use in conjunction withbusbars that are not protectedagainst accidental contact. When used with busbars thatare protected against accidentalcontact, the connection must beprotected against accidentalcontact according to enclosureclass IP2X.
* M8 and M10 screw thread respectively.
38
Switching devices
Kabeldon 2007, edition 1We reserve the right to alter the design and range of our products.
General accessories for OEM
Fig 1.Connecting clamps TC
Fig 2.Connecting clamps TC 300-40
Fig 3.Connecting clamps TCD
Designation ID No. Bar Conductor Clamp WeightWidth Thickness cross Material fig B H1 H2 D
sectionmm mm2 No. mm kg each
TC 50-12 2CGX0 63030202 12 1.5-3 6-50 Al/Cu 1 21 27 5 16 0.02TC 70-15 2CGX0 63030203 15 2-4 10-70 Al/Cu 1 26 47 12 16 0.04TC 120-20 2CGX0 63030204 20 3-5 35-120 Al/Cu 1 32 60 12 22 0.08TC 300-25 2CGX0 63030205 25 4-6 70-300 Al/Cu 1 40 85 13 30 0.2TC 300-40 2CGX0 63030209 40 4-6 95-300 Al/Cu 2 47 84 – 30 0.2TCD 185-25 2CGX0 63030206 25 4-6 2//50-185 Al/Cu 3 48 75 – 30 0.2TCD 300-40 2CGX0 63030207 40 4-6 2//95-300 Al/Cu 3 65 84 – 30 0.3
H1
H2
B D
H
B D
H
B D
39Kabeldon 2007, edition 1
Switching devices
We reserve the right to alter the design and range of our products.
General accessories
TFU 25Single-phase power outlet fortemporary connections, e.g.for a hand lamp or power drill.Mounts directly on the phasebusbar. Cable, max. 35 mm2
Al/Cu. Max. fuse 25 A. Connectors for the PE andN conductors are also needed.
UKRA 90Universal clamp for fixing cableswith Ø 20-90 mm, on mountingrails in a cabinet, for example.
Designation ID No. Rated Cable Dimensions Weightconnection Height Width Depth
data mm2 mm kg each
TFU 25 2CGX0 63140001 230 V, 25 A 1.5 -35 Al/Cu 84 30 185 0.3
Designation ID No. Diameter Qty WeightØ mm per pack kg each
UKRA 90 2GLX0 65300013 20-90 1 0.2
40
Switching devices
Kabeldon 2007, edition 1We reserve the right to alter the design and range of our products.
GBLB 45Street lighting box forfive-wire system (TN-S).• Can be mounted on the
PE/PEN-busbar or amounting plate
• Contactor for 45 A• Protection IP2XConnectable cable cross-section:• Incoming cable to terminal
block, max. 16 mm2
• Outgoing cable fromcontactor, max. 25 mm2
• Incoming/outgoing wiring forcontrol circuits, max. 4 mm2
Lampa type Lamp Lamp- Max QtyWattage rated current lamps/phase
(230 V)W A GBLB 45 GBL 63
High-pressure sodium 150 1.8 17 23Metall-halogen lamps 250 3.0 10 14Uncompensated 400 4.4 7 9
600 6.2 5 71000 10.3 3 4
High-pressure sodium 150 1.0 20 50Metall-halogen lamps 250 1.5 13 33Compensated 400 2.5 8 20
600 3.3 6 151000 6.2 3 8
Mercury, high pressure 125 1.2 34 55Uncompensated 250 2.2 18 29
400 3.3 12 19Mercury, high pressure 125 0.7 28 60Compensated 250 1.3 15 30
400 2.1 10 18
Maximum lighting loads switched by contactor.Data coming from the contactor manufacturer.
Single line diagram for GBLB 45 andGBL 63.
General accessories
Designation ID No. Rated Cable Dimensions Weightdata connection Height Width Depth
mm2 mm kg each
GBLB 45 2CGX0 63190371 400 V, 45 A 16/25/4 Cu 250 105 180 2.2GBL 63 2CGX0 63190374 400 V, 63 A 4Cu/16 Al/Cu 382 250 132 4.8
GBL 63Street lighting box for five-wiresystem (TN-S).• Can be mounted on mounting
plate in the upper section ofKabeldon enclosures CDCMand SDCM.
• Contactor for 63 A• Degree of protection IP3X• 7 M (125) free spsce for kWh
metering, control etc.Connectable cable cross-section:• Incoming/outgoing cable to
terminal block, max. 16 mm2
• Incoming/outgoing wiring forcontrol circuits, max. 4 mm2
41Kabeldon 2007, edition 1
Switching devices
We reserve the right to alter the design and range of our products.
SCASurge current arrester kit.Heavy-duty protection:needed when an overheadline or lightning-conductoris used. The kit comprises:• Three heavy duty
arresters for TN-C (four-wire) system with bracketfor mounting on the PENbar.
• The necessary flexiblewires
• Connectors (AD 95 forphase connection, AD 70for PEN connection)
• Fitting instructions.
SVASurge voltage arrester kit.A medium-duty arrester foruse with undergroundnetworks and where nolightning-conductors areused. The kit comprises:• Four medium-duty
arresters for TN-Ssystems with attachmentfor mounting on the N bar.
• The necessary flexiblewires
• Connectors (AD 95 forphase connection, AD 70for PE and N connection)
• Fitting instructions.Can also be used in aTN-C system.
General accessories
SCA
SVA
Overhead line
Buried cable > 200 m
Lightning conductor
SCA
Choice of surgeprotection:
Choose SCA (heavy-duty protection)• When the building has a lightning
conductor.• Electricity supply via overhead line.• In rural areas with a high frequency
of lightning strikes.• Class: I/B
Choose SVA (medium-duty protection)• With electricity supply via buried cable
(at least 200 metres of cable to the overheadline network).
• Class: II/C
••••• Protect against over-voltagecaused by thunder
••••• Rest voltage < 1,5 kV
Designation ID No. Rated Cable Dimensions Weightdata connection Height Width Depth
mm2 mm kg each
SCA 2CGX0 53190278 230 V (L-N) 25 150 130 90 2.9SVA 2CGX0 53310671 230 V (L-N) 25 90 90 90 1.9
42
Switching devices
Kabeldon 2007, edition 1We reserve the right to alter the design and range of our products.
PBKP 25/50Seal cover for KSKP 25/50.
PSFS 5/17Plate for sealing phase bar.
General accessories
KSKP 25/50Terminal block.
Designation ID No. Qty Rated data Cable Width Weightmodules connection
mm2 mm kg each
KSKP 25 2CGX0 63130005 – 500 V, 63 A 1.5-25 56 0.2KSKP 50 2CGX0 63130007 – 400 V, 160 A 6-50 73 0.3PSFS 5 2CGX0 53050143 5 – – – 0.1PSFS 17 2CGX0 53050144 17 – – – 0.1PBKP 25 2CGX0 53050141 – – – 80 0.1PBKP 50 2CGX0 53050142 – – – 96 0.1
43Kabeldon 2007, edition 1
Switching devices
We reserve the right to alter the design and range of our products.
Dimension drawings All dimensions in mm
355
87,5139
113
42
160
38
77
495
222
160
50
77
495
222
517
242
79
120160
160 150
79
517
242
FD 3300SLD 2
SLD 1SLD 000 SLD 00
44
Switching devices
Kabeldon 2007, edition 1We reserve the right to alter the design and range of our products.
H B D
SLOB 400 365 211 215SLOB 630 384 357 300SLOB 800 410 308 306
H B Dmin-max
LBOC 630 292 313 165-260LBOC 800 292 272 160-255LBOC 1600 363 420 200-260
SLOB
Dimension drawings
LBOC
H B D
SEKO 160 394 147 172
SEKO SEKOB
All dimensions in mm
H B D
SEKOB 250 425 213 205SEKOB 400 425 211 215
D B
H
D
B
H
B
H
D
B
D
H
45Kabeldon 2007, edition 1
Switching devices
We reserve the right to alter the design and range of our products.
Dimension drawings All dimensions in mmDimension drawings
2610
36
ADC 95
33 23
4516
AD 70
All dimensions in mm
45
38
61 31
AD 350
AD 300
AD 95
4625
AD 2150
80
7938
100
78 38
100
161 38
85
85
15
AD 300
AD 300
AD 300ADB 3M + 3 st AD 300
69
69
44
ADO 240
68
49.50 30
30
46
Switching devices
Kabeldon 2007, edition 1We reserve the right to alter the design and range of our products.
Dimension drawings All dimensions in mm
H
D
A
H
D
B
KSST 36 KSST 36 - CDC KSST 316, 316/23, 316/100
B
Designation A H B D
KSST 36 85 226 20 39KSST 36-CDC 85 226 20 39KSST 316 300 320 20 46KSST 316/23 300 320 20 60KSST 316/100 300 320 39 136MSB 316 300 318 10 62MSB 316/23 300 318 10 76MSB 316/100 300 318 10 152
B
D
AH
A
A
B
D
HA
D
H
A
D
H
BB
MSB 316 MSB 316/100MSB 316/23
47Kabeldon 2007, edition 1
Enclosures
We reserve the right to alter the design and range of our products.
48
Enclosures
Kabeldon 2007, edition 1We reserve the right to alter the design and range of our products.
Page
Standards for enclosures ...................................................................................................... 49
Hot-dip galvanized enclosures CDC ..................................................................................... 52
Enclosures for telecommunications and fibre-optic cables .................................................... 54
Hot-dip galvanized enclosures SDC ..................................................................................... 56
Powder coated enclosures for indoor use KSIK .................................................................... 58
Hot-dip galvanized enclosures CDCM with upper section ..................................................... 60
Hot-dip galvanized enclosures SDCM with upper section ..................................................... 62
Pole mounted cable distribution cabinets .............................................................................. 64
Hot-dip galvanized accessory cabinet CDCA ....................................................................... 66
5-wire system ....................................................................................................................... 68
Accessories for enclosures ................................................................................................... 69
Accessories for kWh metering .............................................................................................. 71
Locks and tools ..................................................................................................................... 74
Keys and tools ...................................................................................................................... 75
Examples of combinations of enclosures .............................................................................. 76
Dimension drawings ............................................................................................................. 77
Contents - enclosures
49Kabeldon 2007, edition 1
Enclosures
We reserve the right to alter the design and range of our products.
Standards for enclosures
EnclosureEnclosure series CDC and SDC are madeof hot-dip galvanized sheet steel and arebuilt to these standards:ISO 1461, IEC 60439-1, IEC 60439-5.KSIK enclosures are powder coated steelenclosures for indoor use in environmentclassed C
1 and C
2 to ISO 12944-2.
ProtectionThe degree of protection is IP34D, inaccordance with the requirements ofIEC 60439-5, unless otherwise statedunder “Technical data”.
FoundationIn the CDC range, the ground foundations isan integral part of the design. The length ofthe legs is individually adjustable and the legscan be angled out to avoid protruding buildingfoundations. Separate foundations for ground,floor or wall mounting are available for theSDC range. All below-ground parts have heavy-dutycorrosion protection. KSIK enclosures are for wall mountingonly.
Excavation depthTo ensure an attractive and functionalinstallation in the ground, we recommendexcavating to a depth at which about 10 cmof the foundation is visible above thesurface. A marking label indicates theground level.
Special operating conditionsWith this type of installation, considerationmust be given to the risk of condensation,dust, vibration and impacts. To reduce the risk of condensation, werecommend filling the foundation with sandor using damp barrier.
All enclosures except KSIK have ventilationapertures between the cover plate and thedoor and between the door and the roof,both on the front and back of the enclosure.The ability of the enclosure to withstandexternal blows and impacts has beenchecked by testing at –50 °C in accordancewith the requirements for use in an Arcticclimate in IEC 60439-5.
Sand orLecaFilling mass
0.1
m
Baseplate
50
Enclosures
Kabeldon 2007, edition 1We reserve the right to alter the design and range of our products.
Standards for enclosures
Frost heave and CDCA sliding bar system in the CDC enclosuresreduces the problems that may arise inconnection with frost heave.
External fixing pointsThe sides of all enclosures except theindoor enclosure KSIK are fitted withrivet-nuts to attach marking poles, otherenclosures, boxes, etc.
Openings for temporary outletsBoth sides of CDC and SDC enclosureshave an opening for a temporary poweroutlet or to make protected connectionsbetween two enclosures. The openings arefitted with a revolving seal with a choice offive openings, the largest of which isØ 60 mm.
Where more SDC enclosures are to becombined, special sides are available. Forfurther information contact your supplier orus. On KSIK, there are two covered flangeopenings, size FL 33 in each side panel.
MarkingThere is a space for marking at the top ofthe door of CDC enclosures. On the inside of the door there is a clip toattach a cable distribution cabinet card, etc.
LocksThe enclosures have different locksdepending on their field of application;see the product pages.
51Kabeldon 2007, edition 1
Enclosures
We reserve the right to alter the design and range of our products.
60 M = 850 mm
Enclosures withupper section,CDCM and SDCM.
Standards for enclosure
Meter panel MPF 25/63.
Modular systemAll parts that can be connected to thebusbar system have modular dimensions(one module M = 12.5 mm). This makes iteasy to calculate the space required by aparticular distribution board and then tochoose a suitable enclosure.
Type designationThe type designation of the enclosure isstated as follows:CDC xyz (CDC = enclosure type. This maybe replaced by SDC or KSIK.)x = rated current:0 = cabinet without busbar system4 = busbar system with rated current 400 A6 = busbar system with rated current 630 Ayz = number of modules available on the
busbar (20, 40, 48 etc.)
Enclosures with upper sectionThe following information is added forenclosures with an upper section:
EnclosureAs standard, the enclosure comes with abusbar system in the lower section, but withno equipment in the upper section (the meterspace).
Meter panelsFor the upper section there are meter panels,MPF 25 or MPF 63, to mount the meters on.
The meter panel fixes on to a pre-mountedfixing bar, making fitting simple and flexible.Meter panels have a width of 220 mm. The meter panels come with a suitableintermediate terminal block (KSKP 25 forMPF 25 and KSKP 50 for MPF 63).
Entries to the upper sectionBetween the upper and lower sections thereare openings which are partly covered by aplastic plug with “breakouts”. The largestopening, Ø 50 mm, can take seven 50 mm2
cables.
LocksThe upper section of the enclosure is fittedwith a lock which takes a standardtriangular-section key, so that the customerand the electricity supplier can open thatsection. For the lower section, see theproduct pages.
52
Enclosures
Kabeldon 2007, edition 1We reserve the right to alter the design and range of our products.
Hot-dip galvanized enclosuresCDC
CDC is supplied with a busbar system or witha mounting plate.
• Tested to the requirements of IEC 60439-5.Passes Arctic climate tests.
• Integral foundation.
• Adjustable foundation prepared for fittingof a baseplate.
• The sides have a bracket to attach a snowmarking pole or an accessory cabinet.
• On the inside of the door there is a holderfor a cable distribution cabinet card.
• The embossed areas on the door arecompatible with the most common markingsystems.
• The foundation is prepared for fixing conduitswhen installing heating cables.
• Protection IP34D.
CDC is supplied with a busbar systemor with a perforated mounting plate.
Designation ID No. Equipment Qty Rated Dimensions Weightincluded modules current Height Width Depth
A mm kg each
CDC 020 2CGX0 63300396 mounting plate – – 1200 350 220 36CDC 040 2CGX0 63300397 mounting plate – – 1200 600 220 50CDC 060 2CGX0 63300398 mounting plate – – 1200 850 220 64CDC 420 2CGX0 63300390 busbar system 20 400 1200 350 220 34CDC 440 2CGX0 63300391 busbar system 40 400 1200 600 220 47CDC 460 2CGX0 63300392 busbar system 60 400 1200 850 220 59CDC 640 2CGX0 63300394 busbar system 40 630 1200 600 220 48CDC 660 2CGX0 63300395 busbar system 60 630 1200 850 220 60
53Kabeldon 2007, edition 1
Enclosures
We reserve the right to alter the design and range of our products.
FV, FVDWall spacer.
TN-S systemFive-wire kit.
C20-BP,C40-BP, C60-BPBaseplate.
CDC-CLAMounting kit for cylinderlock.
To be ordered separately:
Contents Enclosure with Enclosure withoutbusbar system busbar systemCDC 420-660 CDC 020-060
Mounting plate No Yes
Busbar system 400 A, 630 A No
PEN bar movable to three positions 400 A No
Anchor bar adjustable to two positions Yes Yes
Foundation leg length individually adjustable Yes Yes
Outlet opening with revolving seal Ø 15-60 mm Yes Yes
Key shape for lock SE Triangular
Heavy-current warning symbol on outside of door Yes No
••••• Stable, versatile enclosure for a varietyof applications
••••• Hot-dip galvanizing gives greatresistance to corrosion
••••• Versatile foundation which can beangled to avoid protruding buildingfoundations
••••• Sliding bar system prevents problemswith frost heave
••••• Outlet opening with a choice of fivesizes makes temporary connectionseasier.
KSPS 6Marking pole.
C20-DB, C40-DB, C60-DBDamp barrier fits allCDC enclosures.
BERG 250Rock hold forcable distributioncabinets typeCDC when installedin rocky ground.
54
Enclosures
Kabeldon 2007, edition 1We reserve the right to alter the design and range of our products.
Hot-dip galvanized enclosures for outdoorapplications or in environments where longlife and durability are essential.
• Tested to the requirements of IEC 60439-5.Passes Arctic climate tests.
• Integral foundation (CDC).
• The sides have a bracket to mark it as anobstacle or for an accessory cabinet.
• On the inside of the door there is a holder for acable distribution cabinet card. The outside iscompatible with the most common markingsystems.
• Protection IP34D.
Enclosures for telecommunicationsand fibre-optic cables
Under an agreementwith the telecomssector, enclosures fortelecommunicationsmust not be fittedwith a triangularlock. Order theseenclosures withCDC-LTC orSDC-LTC.
Enclosure with cable coilerfor fibre-optic cable.
Designation ID No. Mounting plate Dimensions Locks WeightHeight Width Installations depth
mm mm kg each
CDC 020 2CGX0 63300396 700 300 198 Triangular 36CDC 040 2CGX0 63300397 700 550 198 Triangular 50CDC 060 2CGX0 63300398 700 800 198 Triangular 64SDC 048 2CGX0 63300433 770 584 275 Triangular 46SDC 073 2CGX0 63300551 770 898 275 Triangular 58
A cable distribution cabinet forelectric power combined with afibre optical enclosure withfiberduct module.
55Kabeldon 2007, edition 1
Enclosures
We reserve the right to alter the design and range of our products.
To be ordered separately:
••••• Hot-dip galvanizing gives greatresistance to corrosion
••••• Suitable as protection for sensitiveequipment in all types oftelecommunication network.
••••• Cable coiler for handling the cableloop when laying fibre-optic cables
••••• Easy-fit bracket for junction boxfor flexible installation
BK-NBracket for fibre-optic cable junctionbox from Nexans.
SDC-LTCLock for SDCenclosures withtelecommunicationsequipment.
CDC-LTCLock for CDCenclosures withtelecommunicationsequipment.
NK-TCKey to lockCDC-LTC andSDC-LTC.
BK-TBracket for fibre-optic cablejunction box fromTykoflex.
BK-EBracket for fibre-optic cable junctionbox from Ericsson.
FDM-KMounting kitdeveloped formounting fibre ductmodule FDM(Ericsson Ribbonet)on KabeldonIP-system.
C20-DBC40-DBC60-DBDamp barrier fitsall CDC enclosures.
CC 30Cable coiler forabout 30 metres of16 mm OD cable.
EB 435Earth block for4 mm2 or 35 mm2.
KSMP-S 48/73Steel mounting plate for SDC. Perforatedwith 38 mm hole pitch (Ø 3.5 mm).
CC 20Cable coiler forabout 25 metres of13 mm OD cable.
Designation ID No. Dimensions WeightHeight Width Depth
mm kg each
CC 20 2CGX0 53310695 415 215 153 0.6CC 30 2CGX0 53310689 740 550 155 2.5EB 435 2CGX0 43311031 135 35 35 0.1KSMP-S 48 2CGX0 53190332 770 584 19 5.0KSMP-S 73 2CGX0 53190335 770 898 19 8.0BK-E 2CGX0 53310691 167 167 10 0.4BK-N 2CGX0 53310694 295 198 10 0.6BK-T 2CGX0 53310690 225 160 10 0.3FDM-K 2CGX0 53310704 – – – 0,1FDM 2CMA1 31600R1000 506 135 93 1.0C20-DB 2CGX0 53310696 50 350 215 0,2C40-DB 2CGX0 53310697 50 600 215 0,3C60-DB 2CGX0 53310698 50 850 215 0,4CDC-LTC 2CGX0 43311040 – – – 0.1SDC-LTC 2CGX0 43310599 – – – 0.1NK-TC 2CGX0 63190373 113 30 26 0.1BERG 250 2CGX0 63300649 370 130 30 1.9
FDMThe fibre ductmodule isused whenjointing ductsfor opticalfibre.
BERG 250Rock hold for cabledistributioncabinets type CDCwhen installed inrocky ground.
56
Enclosures
Kabeldon 2007, edition 1We reserve the right to alter the design and range of our products.
For quick, simple planning, orderyour copy of the free Connect ITprogram.
Hot-dip galvanized enclosuresSDC
SDC is supplied with or without a busbarsystem. The SDC range is suitable forelectrical distribution boards such asdistributions boards, power distribution boardsin industry, construction site distributionsboards or to feed in standby power. The distribution boards are built to customerrequirements, with direct metering or currenttransformer metering.
• Tested to the requirements of IEC 60439-5.Passes Arctic climate tests.
• Side-hung doors, opening angle >180°.
• The sides have a bracket to attach a snowmarking pole or an accessory cabinet, forexample.
• The depth allows installation of allswitching devices with independentmanual operation.
• Protection IP34D.
Designation ID No. Equipment Qty Rated Dimensions Weightincluded modules current Height Width Depth
A mm kg each
SDC 048 2CGX0 63300433 – – – 895 682 312 46SDC 073 2CGX0 63300551 – – – 895 996 312 58SDC 098 2CGX0 63300437 – – – 895 1310 312 70SDC 448 2CGX0 63300431 busbar system 48 400 895 682 312 48SDC 473 2CGX0 63300552 busbar system 73 400 895 996 312 60SDC 648 2CGX0 63300432 busbar system 48 630 895 682 312 49SDC 673 2CGX0 63300553 busbar system 73 630 895 996 312 62SDC 698 2CGX0 63300434 busbar system 98 630 895 1310 312 75
57Kabeldon 2007, edition 1
Enclosures
We reserve the right to alter the design and range of our products.
GOLV-S 48-98Floor foundation.
FVD, VF 100Wall spacer.
MARK-S 48-98Ground foundation.
BPF-S 48-98Baseplate.
SLUS 48-98Lower door withoutlet opening.
VF-S 30Wall bracket.
To be ordered separately:
••••• Stable, versatile enclosure for a varietyof applications, such as low voltagedistribution boards or as a junction boxfor fibre-optic cables
••••• Hot-dip galvanizing gives greatresistance to corrosion
••••• Doors easy to remove if necessary••••• Openings in the sides for through
busbar systems where more than oneenclosure is installed side by side.
KSMP-S 48-98Mounting plate.
TN-S systemFive-wire kit.
Contents Enclosure with Enclosure withoutbusbar system busbar systemSDC 448-698 SDC 048-098
Mounting plate No No
Busbar system 400 A, 630 A No
PEN bar 400 A No
Foundation No (order separately) No (order separately)
Outlet opening with revolving sealØ 15-60 mm Yes Yes
Key shape for lock Triangular Triangular
Heavy-current warning symbolon outside of door Yes No
KSPS 6Marking pole.
Many different configurations ofthe SDC range can be ordered. Please contact your supplier forfurther information.
58
Enclosures
Kabeldon 2007, edition 1We reserve the right to alter the design and range of our products.
Powder coated enclosuresfor indoor useKSIK
KSIK enclosures are designed for indooruse, environment classes C
1 and C
2*. An
enclosure with a high degree of protection,well suited for installations in industry and inbuildings. The enclosure is developed for distributionboards and therefore has special openingsin its sides to allow busbar systems to passthrough where more than one enclosure iscombined.
• Supplied complete with wall brackets andmounting plate.
• Powder coated in RAL colour 7032.
• Side-hung doors.
• Removable mounting plate.
• Split baseplate.
• Protection IP34D.
Busbar systems for400 A-1600 A on request.
* To ISO 12944-2C1: Heated, dry roomC2: Small amounts of humidity may occur.
Designation ID No. Qty flange Qty Dimensions Weightopenings FL 21 modules Height Width Depthin the base plate mm kg each
KSIK 043 2CGX0 63300411 4 43 900 655 325 42KSIK 063 2CGX0 63300412 6 63 900 895 325 57KSIK 098 2CGX0 63300413 10 98 900 1350 325 75
59Kabeldon 2007, edition 1
Enclosures
We reserve the right to alter the design and range of our products.
••••• Powder coated in RAL colour 7032;harmonises well in an indoor setting
••••• Openings in the sides for throughbusbar systems where enclosures areinstalled side by side.
••••• Split baseplate, making cableinstallation easier
TN-S systemFive-wire kit.
To be ordered separately:
Contents Enclosure KSIK
Mounting plate Yes
Key shape for lock DIN 3
Two covered flange openings, size FL 33 in each side panel. Yes
Baseplate with FL 21 flange openings (see previous page) Yes
Split baseplate Yes
Busbar system On request
KSFS 400 A-1600 ABusbar system.
60
Enclosures
Kabeldon 2007, edition 1We reserve the right to alter the design and range of our products.
The CDCM cabinets are the same as CDCbut are fitted with an upper section which canbe locked separately.CDCM 020 and CDCM 040 comes with amounting plate instead of a busbar system inthe lower section. The CDCM range is suitable for constructionof electrical distribution boards such asgeneral distribution boards, power distributionboards in industry, construction site distribu-tion boards etc., where there is a need tointegrate the equipment with kWh metering.The distribution boards are built to customerrequirements, with direct metering or currenttransformer metering.
• Tested to the requirements of IEC 60439-5(1998). Passes Arctic climate tests.
• Integral foundation.
• The sides have a bracket to attach a snowmarking pole or an accessory cabinet.
• On the inside of the door there is a holderfor a cable distribution cabinet card.
• The embossed areas on the door arecompatible with the most common markingsystems.
• The upper section is fitted with a fixing barfor meter panel MPF 25/63 or withmounting plate MPP 20.
• Protection IP34D.
Hot-dip galvanized enclosureswith upper sectionCDCM
Designation ID No. Equipment Space for Qty Rated Dimensions Weightincluded Qty modules current Height Width Depth
Meter panels A mmMPF 25/MPF 63 kg each
CDCM 020 2CGX0 63300530 Mounting plate 1 – – 1800 350 220 49CDCM 040 2CGX0 63300608 Mounting plate 2 – – 1800 600 220 68CDCM 420 2CGX0 63300430 Busbar system 1 20 400 1800 350 220 47CDCM 440 2CGX0 63300609 Busbar system 2 40 400 1800 600 220 65CDCM 640 2CGX0 63300610 Busbar system 2 40 630 1800 600 220 66
61Kabeldon 2007, edition 1
Enclosures
We reserve the right to alter the design and range of our products.
Low-profile meter cable enclosurecan be built with the following standard products:
• 1 no. cabinet, CDC 020 (page 52)• 1 no. meter panel, MPF 63 (page 71)• 1 no. PEN bar KSNS 417 (page 33)• 1 no. upgrade kit CKM (page 71)• 1 no. customer lock, CDC-LA (page 74)• Where applicable, KSKP 25/50 as well, for supply cable (page 42)
and seal cover PBKP 25/50 (page 42)With this design, the kWh meter is 0.5 metres above the ground.Requirement according to SS 437 01 40 is 0,9 m (h2).
KSPS 6Marking pole.
FV, FVDWall spacer.
MPP 20Mounting plate.
TN-S systemFive-wire kit.
C20-BP,C40-BP, C60-BPBaseplate.
CDC-CLAMounting kit forcylinder lock.
To be ordered separately:
Contents Enclosure with Enclosure withoutbusbar system busbar systemCDC 420-640 CDC 020-040
Mounting plate, lower section No Yes
Busbar system 400 A, 630 A No
PEN bar movable to three positions 400 A No
Anchor bar adjustable to two positions Yes Yes
Foundation leg length individually adjustable Yes Yes
Outlet opening with revolving seal Ø 15-60 mm Yes Yes
50 mm diameter openings between the sectionsfitted with plastic covers Yes Yes
Key shape for lock, lower/upper section SE/customer SE/customer
Heavy-current warning symbol on outside of door Yes No
MPF 25and MPF 63Meter panel.
••••• Stable, versatile enclosure, suitable fora variety of other applications includ-ing distribution boards, junctionboxes, fibre-optic cable
••••• Hot-dip galvanizing gives a greatresistance to corrosion
••••• Versatile foundation which can beangled to avoid protruding buildingfoundations
••••• Sliding bar system prevents problemswith frost heave
••••• 50 mm diameter opening between thesections for flexible cable entry
••••• Revolving seals on the sides of theenclosure make temporary connec-tions easier
BERG 250Rock hold forcable distributioncabinets type CDCwhen installed inrocky ground.
62
Enclosures
Kabeldon 2007, edition 1We reserve the right to alter the design and range of our products.
For quick, simple planning, order yourcopy of the free Connect IT program.
Hot-dip galvanized enclosureswith upper sectionSDCM
The SDCM cabinets are the same as SDCbut are fitted with an upper section whichcan be locked separately. The upper section can be used to housekWh meters or fitted with a mounting platefor various purposes. The SDCM range is suitable for theconstruction of electrical distribution boardssuch as general distribution boards, powerdistribution boards in industry, constructionsite distribution boards etc., where there is aneed to integrate the equipment with kWhmetering.
• Tested to the requirements of IEC 60439-5.Passes Arctic climate tests.
• Side-hung doors, opening angle >180°.
• The sides have a bracket to attach a snowmarking pole or an accessory cabinet.
• The depth allows installation of allswitching devices with independentmanual operation.
• Protection IP34D.
Enclosure with distribution board andkWh metering installed.
Designation ID No. Equipment Space for Qty Rated Dimensions Weightincluded Qty modules current Height Width Depth
Meter panelsMPF 25/MPF 63 A mm kg each
SDCM 048 2CGX0 63300443 – 3 – – 1530 682 312 72SDCM 073 2CGX0 63300561 – 4 – – 1530 996 312 92SDCM 098 2CGX0 63300444 – 5 – – 1530 1310 312 111SDCM 448 2CGX0 63300435 Busbar system 3 48 400 1530 682 312 74SDCM 473 2CGX0 63300562 Busbar system 4 73 400 1530 996 312 94SDCM 648 2CGX0 63300436 Busbar system 3 48 630 1530 682 312 75SDCM 673 2CGX0 63300563 Busbar system 4 73 630 1530 996 312 96SDCM 698 2CGX0 63300438 Busbar system 5 98 630 1530 1310 312 116
63Kabeldon 2007, edition 1
Enclosures
We reserve the right to alter the design and range of our products.
Contents Enclosure with Enclosure withoutbusbar system busbar systemSDCM 448-698 SDCM 048-098
Mounting plate, lower section No No (order separately)
Busbar system 400 A, 630 A No
PEN bar 400 A No
Foundation No (order separately) No (order separately)
Outlet opening with revolving sealØ 15-60 mm Yes Yes
50 mm diameter openings betweenthe sections fitted with plastic covers Yes Yes
Key shape for lock, lower/upper section Triangular/customer Triangular/customer
Heavy-current warning symbol onoutside of the door Yes No
Many different configurations of the SDCrange can be ordered. Please contact your supplier for furtherinformation.
KSPS 6Marking pole.
GOLV-S 48-98Floor foundation.
FVD, VF 100Wall spacer.
MARK-S 48-98Ground foundation.
BPF-S 48-98Baseplate.
SLUS 48-98Lower door withoutlet opening.
VF-S 30Wall bracket.
To be ordered separately:
MPP-S 48, KSMP-S 48-98,MPT-S 48Mounting plate.
••••• Hot-dip galvanizing gives a great resistanceagainst corrosion
••••• Versatile enclosure for a variety ofapplications, such as low voltagedistribution boards or as a junction boxfor fibre-optic cables
••••• Openings in the sides can be adapted forthrough busbar systems where enclosuresare installed side-by-side
••••• 50 mm diameter opening between thesections for flexible cable entry
••••• Revolving seals on the sides of the enclosuremake temporary connections easier
MPF 25/63Meter panel.
TN-S systemFive-wire kit.
64
Enclosures
Kabeldon 2007, edition 1We reserve the right to alter the design and range of our products.
Pole-mounted cabledistribution cabinets
Pole-mounted cable distribution cabinets aresupplied complete with integral pole bracket,400 A busbar system, PEN bar and anchorbar, as well as a cable duct to the ground.
• On the back there is an opening for anearthing line and an opening fortemporary connections.
• Breakouts for up to seven cablechannels.
• Protection IP34D.
Breakouts for cable channels onthe back of the pole-mountedcabinet.
A cable duct to the ground is suppliedwith the cabinet.
Opening fortemporaryconnections,Ø 48 mm
Opening forearthing
Designation ID No. Equipment Qty Rated Qty Dimensions Weightincluded modules current cable Height Width Depth
A ducts mm kg each
CDCP 020 2CGX0 63300621 Mounting plate 20 – 0 - 3 1200 350 382 45CDCP 040 2CGX0 63300622 Mounting plate 40 – 0 - 7 1200 600 382 61CDCP 420 2CGX0 63300428 Busbar system 20 400 0 - 3 1200 350 382 43CDCP 440 2CGX0 63300429 Busbar system 40 400 0 - 7 1200 600 382 58
65Kabeldon 2007, edition 1
Enclosures
We reserve the right to alter the design and range of our products.
KKCSJoining piece made ofnon-corrosive andnon-magnetic material.
KKSExtra support forcable channel.
KHB 5Holder for 3 to 5 cablechannels.
KHB 3Holder for 1 to 3 cablechannels.
••••• Hot-dip galvanizing gives greatresistance to corrosion
••••• Complete with pole bracket andcable duct
••••• Openings for earthing andtemporary connections
••••• Up-to seven cable channels••••• Easy to assemble – not many parts
To be ordered separately:
CDCP-TPBaseplate for sealing theopening at the bottom.
Contents Enclosure with Enclosure withoutbusbar system busbar systemCDCP 420, 440 CDCP 020, 040
Cable duct to the ground Yes Yes
Busbar system 400 A No
PEN bar 400 A No
Anchor bar Yes Yes
Key shape for lock SE Triangular
Heavy-current warning symbol on outside of door Yes No
KKC 5Cable channel2 x 2.4 m withjoining piece KKCS.
KHB 7Holder for 5 to 7 cablechannels.
Designation ID No. Qty Dimensions Weightper pack Height Width Depth
mm kg each
KKCS 2CGX0 53190244 1 100 57 61 0.2KHB 3 2CGX0 63190245 1 105 184 250 0.3KHB 5 2CGX0 63190246 1 105 294 250 0.4KHB 7 2CGX0 63190279 1 105 404 250 0,6KKC 5 2CGX0 53190243 1 kit 2400 55 55 3.2KKS 2CGX0 63190286 1 30 250 190 0.4CDCP-TP 2CGX0 53310728 1 16 260 191 0.6
66
Enclosures
Kabeldon 2007, edition 1We reserve the right to alter the design and range of our products.
Hot-dip galvanized accessory cabinetCDCA
Accessory cabinet for mounting onanother enclosure. The cabinet comeswith a mounting plate.
• There are outlet openings in thesides. The opening on the right-handside has a revolving seal with achoice of five openings. The seal canbe moved to the left-hand side.
• The bottom of the cabinet has anopening with integral strain relief fortemporarily connected cables. Whennot in use, the opening is blanked offwith the cover supplied.
• Inserts for temporary power outletsKSMU 16/32/63 can be installed inthe cabinet, as well as meter panelMPF 25/63. Where meter panelMPF 25/63 is installed, upgrade kitCKM is required.
The openings on the sides of thecabinet is used for temporarypower outlets, etc.
CDCA mounted on the rightside of CDC 020.
Designation ID No. Dimensions WeightHeight Width Depth
mm kg each
CDCA 2CGX0 63300451 730 280 218 14.5
67Kabeldon 2007, edition 1
Enclosures
We reserve the right to alter the design and range of our products.
KSMUB 16/321x16 + 2x10 A or 1x32 +2x10A with residual currentdevice, miniature circuit-breaker and space for akWh meter. Strength of short circuit6 kA in combination withequipment max 63 A.
To be ordered separately:
Contents Accessory cabinet
CDCA
Mounting plate Yes
Outlet opening with revolving seal Ø 15-60 mm Yes
Opening at the bottom with integral strain relieffor temporarily connected cables Yes
Key shape for lock Triangular
••••• Hot-dip galvanizing gives greatresistance to corrosion
••••• Integral strain relief in the bottom of thecabinet
••••• Revolving seal with a choice of five sizesin the opening on the side of the cabinet.
CKMUpgrade kit for installingmeter panel MPF 25/63.
MPF 25/63Meter panel for 25 Aor 63 A.
CDCA-CDCable protection duct for forexample fibre optic cables.– Max cable diameter 25 mm
inside cabinet.– Max. diameter for optical fibre
pipes is 45 mm.– Degree of protection IP34D.
Designation ID No. Cable Outlet Dimensions Weightconnection Height Width Depth
mm² mm kg each
KSMUB 16 2CGX0 63300611 6 1x16 A + 2x10 A 711 222 191 5.5KSMUB 32 2CGX0 63300612 6 1x32 A + 2x10 A 711 222 191 5.5CKM 2CGX0 53390034 – – – – – 0.02MPF 25 2CGX0 53310644 – – 570 220 115 5.0MPF 63 2CGX0 53310645 – – 570 220 115 5.0CDCA-CD 2CGX0 53310705 – – 380 240 66 2.3
68
Enclosures
Kabeldon 2007, edition 1We reserve the right to alter the design and range of our products.
5-wire system
••••• Simple to fit when upgradingan existing cabinet
Kit for conversion to 5-wiresystem, TN-S or TN-C-S. The kit includes a 400 Abusbar with accidentalcontact protection.
Upgrading kit for 1000 Abusbars. Please contact your supplierfor further information.
Designation ID No. Fits enclosure Rated current Length WeightA mm kg each
C20-TNS 2CGX0 53310613 CDC 20 400 333 0.6C40-TNS 2CGX0 53310614 CDC 40 400 583 0.7C60-TNS 2CGX0 53310615 CDC 60 400 833 0.9S48-TNS 2CGX0 53320165 SDC 48 400 584 0.9S73-TNS 2CGX0 53320180 SDC 73 400 898 1.0S98-TNS 2CGX0 53320166 SDC 98 400 1212 1.2
69Kabeldon 2007, edition 1
Enclosures
We reserve the right to alter the design and range of our products.
VF 100Wall bracket for enclosures CDC andSDC. Keeps the CDC cabinet 100 mmaway from the wall of the building. For SDC, the distance from the wallis 8 mm.
FVDWall spacer, used together with FV.
FVWall bracket for enclosuresCDC/CDCM.
Accessories for enclosures
C20-BP, C40-BP, C60-BPSheet steel foundation baseplatefor CDC/CDCM.
KSPS 6Marking pole.
C20-DB, C40-DB, C60-DBDamp barrier fits all CDC enclosures.
FDM-KMounting kit developed forinstalling fibre duct moduleFDM (Ericsson Ribbonet) inKabeldon enclosures.
C60-XAExtra anchor bar which can beinstalled under the cover plate inCDC 60. It is used when replacingenclosure where the cable mustbe jointed.
Designation ID No. Suitable for Dimensions WeightHeight Width Depth
mm kg each
C 20-BP 2CGX0 53310725 CDC/CDCM 20 27 344 130 0.8C 40-BP 2CGX0 53310726 CDC/CDCM 40 27 594 130 1.5C 60-BP 2CGX0 53310727 CDC 60 27 844 130 2.2FDM-K 2CGX0 53310704 CDC/SDC – – – 0.1FV 2CGX0 63190225 CDC/CDCM 50 70 135 1.9BERG 250 2CGX0 63300649 CDC/CDCM 370 130 30 1.9FDM 2CMA1 31600R1000 CDC/SDC 506 135 93 1,0C20-DB 2CGX0 53310696 CDC/SDC 50 350 215 0.2C40-DB 2CGX0 53310697 CDC/SDC 50 600 215 0.3C60-DB 2CGX0 53310698 CDC/SDC 50 850 215 0.4VF 100 2CGX0 53310678 CDC/CDCM/SDC/SDCM 40 228 35 0.2FVD 2CGX0 63190241 FV – Ø 47 85 0.7KSPS 6 2CGX0 63190145 CDC/CDCM/SDC/SDCM 1500 30 30 3.8C60-XA 2CGX0 53310667 CDC 60 42 935 50 1.7
FDMFibre duct module isused for jointing fibreoptic ducts. The duct inthe service cable isjointed to a multi-ductcable.
BERG 250Rock hold for cablecabinet CDC-serieswhen rocky ground.
70
Enclosures
Kabeldon 2007, edition 1We reserve the right to alter the design and range of our products.
Accessories for enclosuresSDC and SDCM
GOLV-S 48-98Complete foundationwhen installed on a floor.
MARK-S 48-98Complete foundationwhen installed in theground.
BPF-S 48-98Baseplate with 4, 6 or10 FL 21 flange openings.
VF-S 30Wall bracket. Two required percabinet. Gives 30 mm free space behindthe cabinet.
SLUS 48-98Door with outlet opening at thebottom for temporary connections.The outlet opening measures60 mm x 240 mm.
Designation ID No. Fits enclosure Dimensions WeightHeight Width Depth
mm kg each
SLUS 48 2CGX0 53310666 SDC/SDCM 48 288 626 22 5SLUS 73 2CGX0 53310684 SDC/SDCM 73 288 940 22 7.5SLUS 98 2CGX0 53310668 SDC/SDCM 98 288 1254 22 10.0MARK-S 48 2CGX0 63300439 SDC/SDCM 48 940 672 303 30MARK-S 73 2CGX0 63300549 SDC/SDCM 73 940 986 303 36MARK-S 98 2CGX0 63300440 SDC/SDCM 98 940 1300 303 42GOLV-S 48 2CGX0 63300441 SDC/SDCM 48 400 672 303 23GOLV-S 73 2CGX0 63300550 SDC/SDCM 73 400 986 303 30GOLV-S 98 2CGX0 63300442 SDC/SDCM 98 400 1300 303 36BPF-S 48 2CGX0 53310629 SDC/SDCM 48 30 672 282 4BPF-S 73 2CGX0 53310682 SDC/SDCM 73 30 986 282 5BPF-S 98 2CGX0 53310630 SDC/SDCM 98 30 1300 282 6VF-S 30 2CGX0 53310643 SDC/SDCM 500 40 40 0.5
71Kabeldon 2007, edition 1
Enclosures
We reserve the right to alter the design and range of our products.
Accessories for kWh metering
CKMUpgrade kit for installing meter panelMPF 25/63 in accessory cabinet CDCAor in low-profile meter cable cabinet.
MPF 25/63Meter panel with terminal block.
PBKP 25/50Seal cover for KSKP 25/50.
Designation ID No. Description Rated Dimensions Weightcurrent Height Width Depth
A mm kg each
MPF 25 2CGX0 53310644 Meter panel 25 570 220 115 5.0including terminalblock KSKP 25
MPF 63 2CGX0 53310645 Meter panel 63 570 220 115 5.0including terminalblock KSKP 50
CKM 2CGX0 53390034 Upgrade kit – – – – 0.02PBKP 25 2CGX0 53050141 Seal cover – – 80 – 0.1PBKP 50 2CGX0 53050142 Seal cover – – 96 – 0.1
72
Enclosures
Kabeldon 2007, edition 1We reserve the right to alter the design and range of our products.
Accessories for kWh metering
TRAFO-C 630 ochTRAFO-S 630/1200Complete kits for current transformer metering.For 630 A or 1200 A.
TRAFO-C and TRAFO-S contains:
1 kit Busbar bridges incl. busbar supports1 no. Fuse-switch disconnector1 kit Gauge pieces for 10 A2 no. Neutral terminals1 no. Seal cover
Rated A B(max) C(min) D(min) E(max)current mm mm mm mm mm
630 85 50 30 10 401200 100 50 60 20 40
B A
D
CE
KSSM-S 630/1200Busbar bridges incl. busbar supportsfor current transformer. For 630 A or1200 A. May only be installed on deadbusbar.
Designation ID No. Fits enclosure Qty Rated data Weightmodules kg each
TRAFO-C 630 2CGX0 63190357 CDC, CDCM 13 500 V, 630 A 5.0TRAFO-S 630 2CGX0 63190356 SDC, SDCM, KSIK 13 500 V, 630 A 5.0TRAFO-S 1200 2CGX0 63190355 SDC, SDCM, KSIK 19 500 V, 1200 A 8.4KSSM-S 630 2CGX0 63090017 SDC, SDCM, KSIK 9 500 V, 630 A 2.7KSSM-S 1200 2CGX0 63090018 SDC, SDCM, KSIK 15 500 V, 1200 A 6.1
73Kabeldon 2007, edition 1
Enclosures
We reserve the right to alter the design and range of our products.
Accessories for kWh metering
MPP-S 48Mounting plate, steel, for theupper section of enclosurestype SDCM 48 and SDCM 73.Two plates are used forSDCM 98.
MPP 20Mounting plate, steel, forupper section of CDCM.Two plates are used forCDCM 40.
MPT-S 48MPT-S 73Mounting plate, wood, for theupper section of SDCM 48and SDCM 73. Two platesMPT-S 48 are used forSDCM 98.
Designation ID No. Fits enclosure Dimensions WeightHeight Width Depth
mm kg each
MPP 20 2CGX0 53310665 CDCM 540 268 25 2.0MPT 40 2CGX0 53310724 CDCM 550 550 12 1.75MPP-S 48 2CGX0 53190334 SDCM 580 585 25 3.0MPT-S 48 2CGX0 53310647 SDCM 580 600 12 2.2MPT-S 73 2CGX0 53310688 SDCM 580 900 12 3.3KSMP-S 48 2CGX0 53190332 SDC, SDCM 770 584 19 5.0KSMP-S 73 2CGX0 53190335 SDC, SDCM 770 898 19 8.0KSMP-S 98 2CGX0 53190333 SDC, SDCM 770 1212 19 11.0
MPT 40Mounting plate, steel, forupper section of CDCM 40.
KSMP-S 48KSMP-S 73KSMP-S 98Mounting plate, steel, for SDC andthe lower section of enclosures typeSDCM. KSMP-S 48/73 is perforatedwith hole pitch 38 mm (Ø 3.5).
74
Enclosures
Kabeldon 2007, edition 1We reserve the right to alter the design and range of our products.
SDC-LACustomer lock forSDC/SDCM.
Locks and tools
SDC-LDDIN lock forSDC/SDCM.
KSCAAdaptor ring forASSA/Abloy lock forSDC.
SDC-LTTriangular lock forSDC/SDCM.
SDC-LSESE lock forSDC/SDCM.
CDC-CLAKit for fitting cylinder locktype ASSA/Abloy/Triovingto CDC.
SDC-LTCLock forSDC/SDCM withequipment fortelecommunication.
Designation ID No. Suitable key WeightKSNR 4 NK 3 NK 5 NK 30 NKD 3 NK-TC kg each
CDC-LT 2CGX0 43310739 – x x x – – 0.1CDC-LA 2CGX0 43310740 x x x x – – 0.1CDC-LD 2CGX0 43310742 – – – – x – 0.1CDC-LSE 2CGX0 43310743 – – – x – – 0.1CDC-LTC 2CGX0 43311040 – – – – – x 0.1SDC-LT 2CGX0 43310597 – x x x – – 0.1SDC-LA 2CGX0 43310596 x x x x – – 0.1SDC-LD 2CGX0 43310595 – – – – x – 0.1SDC-LSE 2CGX0 43310598 – – – x – x 0.1SDC-LTC 2CGX0 43310599 – – – – – x 0.1CDC-CLA 2CGX0 53310669 – – – – – – 0.1KSCA 2CGX0 53190278 – – – – – – 0.1
CDC-LDDIN 3 lockCDC/CDCM.
CDC-LTTriangular lock forCDC/CDCM.
CDC-LSESE lock forCDC/CDCM.
CDC-LACustomer lock forCDC/CDCM.
CDC-LTCLock forCDC/CDCM withequipment for tele-communication.
75Kabeldon 2007, edition 1
Enclosures
We reserve the right to alter the design and range of our products.
KSNR 4Key for customer lock.
NKD 3Key for DIN lock.
NK 30Key for triangular lockand SE lock with dooropener.
NK 3Key for triangularlock with dooropener.
NK-TCKey for lock forCDC-LTC andSDC-LTC with dooropener.
VHB 68Insulating hand tools.6 and 8 mm hexagonspanner. Fits torquewrench with 1/2" squarepeg.
Keys and tools
Designation ID No. Weightkg each
KSNR 4 2CGX0 43190104 0.1NKD 3 2CGX0 43190661 0.1VHB 68 2CGX0 63090014 0.4NK 3 2CGX0 63190370 0.1NK 30 2CGX0 63190369 0.1NK-TC 2CGX0 63190373 0.1
The door opener is usedto facilitate opening theenclosure if the doorhas jammed.
76
Enclosures
Kabeldon 2007, edition 1We reserve the right to alter the design and range of our products.
Examples of combinations of enclosures
CDC 40 + SDC 98 SDC 48 + SDC 98
SDC 98 + SDCM 48 SDCM 48 + SDCM 98
CDC 40 + CDCASDC 98 + BPF-S 98
77Kabeldon 2007, edition 1
Enclosures
We reserve the right to alter the design and range of our products.
350
1200
300-
840
900
500
6828
083
0
max Ø 60
240300
198
Enclosures CDC
220
Mountingplate
300x700
Mounting plate550x700
Mounting plate800x700
M10
Enclosures SDC
Dimension drawings
600 850
All dimensions in mm
1310 (SDC 98)
889
400
940
100
276
500
max Ø 60
M10
996 (SDC 73)
682 (SDC 48) 312
296
78
Enclosures
Kabeldon 2007, edition 1We reserve the right to alter the design and range of our products.
Enclosures KSIK
Enclosures CDCM with upper section
Dimension drawings
600 (CDCM 40)
518
350 (CDCM 20)
268 220
175
240
360
max Ø 60
1800
570
1100
1440
1500
300-
840
830
All dimensions in mm
305
FL 33
FL 33
655 (KSIK 43) 895 (KSIK 63) 1350 (KSIK 98) 325
900
79Kabeldon 2007, edition 1
Enclosures
We reserve the right to alter the design and range of our products.
682 (SDCM 48) 1310 (SDCM 98) 312
889
400
940
100
276
500
max Ø 60
634
1523
Enclosures SDCM with upper section
263
M10
Accessory cabinet CDCA
280
222 218
195
165 28
0
730
Mountingplate
220x709
Dimension drawings
996 (SDCM 73)
All dimensions in mm
80
Enclosures
Kabeldon 2007, edition 1We reserve the right to alter the design and range of our products.
350/600 170 220
253 78
1870
670
330
1100
1200
Pole mounted cable distribution cabinetsCDCP
Dimension drawings All dimensions in mm
81Kabeldon 2007, edition 1 We reserve the right to alter the design and range of our products.
Busbar system 400 A 630 A 1000 A 1600 A
Rated operational voltage, Ue V 690 690 690 690
Rated insulation voltage, Ui V 1000 1000 1000 1000
Rated conventional thermal current, Ith
and rated operational current, Ie A 400 630 1000 1600
Rated short-time withstand current, Icw kAeff/s 30/0.21) 23/11) 40/11) 70/11)
Rated fused short-circuit current, Icf kAeff 50 85 50 85 – –max A 3//315 3//250 3//315 3//250 – –
Rated peak withstand current, Ipk kApeak 55 55 – –
Rated peak withstand current, 1 metre longbusbar with no devices fitted, Ipk kApeak – – 50 85
Degree of protection acc. to IEC 60529 IP2X IP2X IP2X IP2X
Technical data
Switching device with dependentmanual operation, uninterrupted duty SLD 000 SLD 00 SLD 1 SLD 2 FD 3300
Rated operational voltage, Ue V 4001) 4001) 4001) 4001) 400
Rated insulation voltage, Ui V 690 690 690 690 690
Rated impulse withstand voltage, Uimp kV 8 8 8 8 8
Rated operational current, Ie
and rated conventional thermal 100 160 250 400 400current, Ith
2) A 400 3) 600 3)
Utilization category accordingto IEC 60947-3 AC-23B AC-23B AC-23B AC-23B AC-21B
Rated short-time withstandcurrent, Icw kArms/s – – – – 15/1
Rated peak withstandcurrent, Ipk kApeak – – – – 42
Rated conditional (fused) kArms, 50 50 50 50 50short-circuit current, I max A fuse 100 160 250 400 2//400
Degree of protection accordingto IEC 60529 IP2X 4) IP2X 4) IP2X IP2X IP2X
Connectable conductor cross-section,Cu/Al mm2 2.5-95 2.5-95 50-300 50-300 50-300
Remarks1) Partially type tested.2) Fuse with power dissipation according to IEC 60269-2-1.3) With linking knives.4) Open switch IP1X. Depending on design dimensions of the fuse.
Technical data
1) Test precondition: ΔT=100 K. Final busbar temperature max. 150°C.
82 Kabeldon 2007, edition 1We reserve the right to alter the design and range of our products.
Switching devices with SEKO SEKOB SLOB LBOC AS-T3with ABB Sace
independent manual operation 160 250 400 400 630 800 630 800 1600 Tmax T3
Rated operational voltage, Ue
V 690 690 690 690 690 690 690 690 690 415 690
Rated insulation voltage, Ui
V 750 1000 1000 1000 1000 1000 1000 1000 1000 800
Rated conventional thermalcurrent, I
th and rated
operational current, Ie
A 160 250 400 400 630 800 630 800 1600 250
Rated conventional thermalcurrent, I
thenclosed and rated 160 250 355 355 630 800 630 800 1600 220
operational current, Ie
A 4001)
4001)
Utilization category acc. toIEC 60947-3; 415 V AC AC-22A AC-23A AC-23A AC-23A AC-23A AC-22A AC-23A AC-22A AC-22A –
Utilization category according to
IEC 60947-2; 1000 V AC – – – – – – – – – A
Rated short-time withstandcurrent, I
cwkA
rms/s 5 8 10 10 16 16 17 17 50 27
Rated peak withstand current, Ipk
kApeak
– – – – – 80 80 105 –
Rated conditional short-circuit kA – – – – – – – – – 50 8current, Icc
Rated fused short-circuit kArms 50 50 50 50 50 50 – – – –current, Icf max A 160 250 400 400 630 800 – – – –
Degree of protection acc. toIEC 60529 IP2X IP2X IP2X IP2X IP2X IP2X IP2X IP2X IP2X IP2X
Connectable conductorcross-section, Cu/Al mm2 50-300 50-300 50-300 50-300 – – – – – 50-300
Technical data
Technical data
1) With linking knife.
Connectors1) ADC AD ADO AD AD AD AD ADB KSSM-S KSSM-S AB AB25 70 2402) 3502) 95 300 2150 3M 630 1200 800 1200
Rated operational voltage, Ue V 690 690 690 690 690 690 690 500 500 500 500 500
Rated insulation voltage, Ui V – – – – 690 690 690 690 690 690 – –
Rated conventional thermalcurrent, Ith and ratedoperational current, Ie A 63 200 400 400 200 630 400 500 630 1200 800 1200
Max. fuse A – – – – – 2//200 – – – – – –
Rated short-time withstandcurrent, Icw kAeff/s – 19/1 – 25/1 30/0.2 30/1 30/0.2 – – – – –
Rated conditional short-circuit kAeff – – – – 50 50 50 – – – – –current with fuse Icf max A – – – – 200 400 2//200 – – – – –
Degree of protection acc. toIEC 60529 IP00 IP00 IP00 IP00 IP2X IP2X IP2X IP2X IP2X IP2X IP00 IP00
Connectable conductorcross-section, Cu/Al mm2 1.5-25 6-95 120-240 3x6-50 6-95 50-300 35-2//150 50-300 – – – –
Testing standards:1) SEN 24 15 10, SFS 2663, VDE 0220/12) IEC 61238-1
83Kabeldon 2007, edition 1 We reserve the right to alter the design and range of our products.
Technical data
Technical data
Cable distribution cabinets 400 A 630 A
Rated operational voltage, Ue V 400 400
Rated insulation voltage, Ui V 1000 1000
Rated conventional thermal current, Ith
and rated operational current, Ie A 400 630
Max. fuse A 3//315 3//315
Rated short-time withstandcurrent, Icw kAeff/s 30/0.21) 23/11)
Rated fused short-circuit kA eff 50 85 50 85current, lcf max A 3//315 3//250 3//315 3//250
Rated peak withstand current, lpk kApeak 55 55
Degree of protection acc. to Busbar system IP2X IP2XIEC 60529 Enclosure IP34D IP34D
1) Test precondition: ΔT=100 K. Final busbar temperature max. 150° C.
Accessories PHD 2 PHD 2 SDC JDD 000 JDD 00 JDD 1 JDD 2
Rated operational voltage, Ue V 400 400 690 690 690 690
Rated insulation voltage, Ui V 690 690 – – – –
Rated operational current, Ie andrated conventional thermal current, Ith A 400 1) 400 1) – – – –
Utilization category acc to IEC 60947-3 AC-23B AC-23B – – – –
Rated short-time withstandcurrent, Icw kArms/s – – 6.1/1 6.1/1 16.6/0.5 16.6/0.5
Rated peak withstand current, Ipk kApeak – – 10.9 10.9 33.8 33.8
Rated fused short-circuit current, I kArms 50 50 – – – –max. A 400 400 – – – –
Remarks1) Fuses with power dissipation according to IEC 60269-2-1.
84 Kabeldon 2007, edition 1We reserve the right to alter the design and range of our products.
AAB 1200-53 37AB 1200-70 37AB 800-53 37AD 2150 31AD 300 31AD 350 31AD 70 31AD 95 31ADB 3M 31ADC 25 31ADN 31ADO 240 31ADR H12 37ADR M10 37ADR M8 37AS-T3 30
BBERG 250 53,55,61,69BK-E 55BK-N 55BK-T 55BPF-S 48 57, 63, 70BPF-S 73 57, 63, 70BPF-S 98 57, 63, 70
CC 20-BP 53, 61, 69C20-DB 53, 55, 69C 20-TNS 36, 68C 40-BP 53, 61, 69C40-DB 53, 55, 69C 40-TNS 36, 68C 60-BP 53, 61, 69C60-DB 53, 55, 69C 60-TNS 36, 68C 60-XA 69CC 20 55CC 30 55
CCDC 020 52, 54, 61CDC 040 52, 54CDC 060 52, 54CDC 420 52CDC 440 52CDC 460 52CDC 640 52CDC 660 52CDC-CLA 53, 61, 74CDC-LA 61, 74CDC-LD 74CDC-LSE 74CDC-LT 74CDC-LTC 55, 74CDCA 66CDCA-CD 67CDCM 020 60CDCM 040 60CDCM 420 60CDCM 440 60CDCM 640 60CDCP 020 64CDCP 040 64CDCP 420 64CDCP 440 64CDCP-TP 65CKM 61, 67, 71Connect IT 11
EEB 435 55
FFD 3300 27FDM 55, 69FDM-K 55, 69FH-S 250/400 28FV 53, 61, 69FVD 53, 57, 61, 63, 69
Designations in alphabetical order
Designation Page No. Designation Page No.
Contentents
85Kabeldon 2007, edition 1 We reserve the right to alter the design and range of our products.
Designation Page No. Designation Page No.
GGBL 63 40GBLB 45 40GOLV-S 48 57, 63, 70GOLV-S 73 57, 63, 70GOLV-S 98 57, 63, 70
JJDD 000 23JDD 00 24JDD 1 25JDD 2 26
KKBS 20 37KFBD 27KHB 3 65KHB 5 65KHB 7 65KKC 5 65KKCS 65KKS 65KLAP T5 630 30KLKB-S 1200 34KLKB-S 630 34KN 00 23, 24, 28KN 1 25KNB 2 26, 28KSBD 00 23, 24KSBD 2 25, 26KSBH 300 31KSCA 74KSFS 10126 32, 59KSFS 1083 32, 59KSFS 1098 32, 59KSFS 16126 32, 59KSFS 16149 32, 59KSFS 16181 32, 59KSFS 1683 32, 59KSFS 1698 32, 59
KKSFS 420 32, 59KSFS 440 32, 59KSFS 443 32, 59KSFS 448 32, 59KSFS 460 32, 59KSFS 463 32, 59KSFS 473 32, 59KSFS 640 A 32, 59KSFS 643 A 32, 59KSFS 648 A 32, 59KSFS 660 A 32, 59KSFS 663 A 32, 59KSFS 673 A 32, 59KSFS 698 A 32, 59KSFT 70KSIK 043 58KSIK 063 58KSIK 098 58KSKP 25 42, 61KSKP 50 42, 61KSMP-S 48 55, 57,63, 73KSMP-S 73 55, 57,63, 73KSMP-S 98 57,63, 73KSMUB 16 67KSMUB 32 67KSNR 4 75KSNS 10126 33KSNS 10149 33KSNS 10181 33KSNS 1083 33KSNS 1098 33KSNS 1098 KSIK 33KSNS 417 33, 61KSNS 420 33KSNS 440 33KSNS 443 33KSNS 460 33KSNS 463 33KSNS 473 33KSNS 498 33
Designations in alphabetical order
86 Kabeldon 2007, edition 1We reserve the right to alter the design and range of our products.
KKSNS 498 KSIK 33KSPS 6 53, 57, 61,63, 69KSSM-S 630 72KSSM-S 1200 72KSST 36 34KSST 36 - CDC 34KSST 316 34KSST 316/100 34KSST 316/23 34KSST-CDC 34
LLBOC 630 29LBOC 800 29LBOC 1600 29
MMARK-S 48 57, 63, 70MARK-S 73 57, 63, 70MARK-S 98 57, 63, 70MPF 25 61, 63, 67, 71MPF 63 61, 63, 67, 71MPP 20 61, 73MPP-S 48 63, 73MPT 40 73MPT-S 48 63, 73MPT-S 73 73MSB 316 35MSB 316/100 35MSB 316/23 35
NNK 3 75NK 30 75NKD 3 75NK-TC 55, 75
PPBKP 25 42, 61, 71PBKP 50 42, 61, 71PHD 2 26PHD 2 SDC 26PH-S 250/400 28PSFS 5 42PSFS 17 42
RRKMB 900 37
SS 48-TNS 36, 68S 73-TNS 36, 68S 98-TNS 36, 68SCA 41SDC 048 54, 56SDC 073 54, 56SDC 098 56SDC 448 56SDC 473 56SDC 648 56SDC 673 56SDC 698 56SDC-LA 74SDC-LD 74SDC-LSE 74SDC-LT 74SDC-LTC 55,74SDCM 048 62SDCM 073 62SDCM 098 62SDCM 448 62SDCM 473 62SDCM 648 62SDCM 673 62SDCM 698 62SEKO 160 28SEKOB 250 28SEKOB 400 28
Designations in alphabetical order
Designation Page No. Designation Page No.
Contentents
87Kabeldon 2007, edition 1 We reserve the right to alter the design and range of our products.
Designation Page No. Designation Page No.
Designations in alphabetical order
SSLD 00 24SLD 000 23SLD 1 25SLD 2 26SLOB 400 29SLOB 630 29SLOB 800 29SLUS 48 57, 63, 70SLUS 73 57, 63, 70SLUS 98 57, 63, 70SVA 41
TTC 50-12 38TC 70-15 38TC 120-20 38
TTC 300-25 38TC 300-40 38TCD 185-25 38TCD 300-40 38TFU 25 39TRAFO-C 630 72TRAFO-S 630 72TRAFO-S 1200 72
UUKRA 90 39
VVF-S 30 57, 63, 70VF100 57, 63, 69VHB 68 75
Contentents