Agenda (2.5 hours)
1. International Paint Product Range
2. Structural Steel
3. Corrosion Under Insulation (CUI)
4. Tank Linings
5. Concrete
6. Pipelines
7. Passive Fire Protection (PFP)
8. Summary
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale. Any information given here is for guidance only and no representation or warranty is given as to its potential use.
International Paint The Oil & Gas Partner of Choice
International Paint supply all the major multinationals in the Oil & Gas Industry.
International Paint are named on the Shell, Exxon, Chevron, Saudi Aramco, Dow, Vopak global specifications to name but a few.
We work closely with the owners to provide technical support and ensure our products meet their needs through test work.
Our support ensures that the owners see the true value of using International Paint products.
On-site we can provide technical consultation on choice of paint for difficult maintenance jobs as well as Technical Support Representatives to attend application of the paint and train the applicator.
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale. Any information given here is for guidance only and no representation or warranty is given as to its potential use.
International Paint – Supplying all your paint needs
Corrosion Under
InsulationTank
Externals
High Temperature Surfaces
Tank Internals
Structural Steel
OEMConcrete
Fire Protection
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale. Any information given here is for guidance only and no representation or warranty is given as to its potential use.
International Paint - Technology Leader
International Paint have various systems which utilise market leading technology to provide solutions to your most difficult corrosion issues:
Intertherm 751 CSA – unique, patented heat & corrosion resistance Enviroline – High performance, thick film, rapid cure tank linings Ceilcote – Resistant to the most highly aggressive chemical attack Intercrete – Cementitious repair mortars and linings Chartek – 100% volume solids passive fire protection
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale. Any information given here is for guidance only and no representation or warranty is given as to its potential use.
Structural Steel
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale. Any information given here is for guidance only and no representation or warranty is given as to its potential use.
Typical Paint Specification for Un-Insulated External Surfaces <120˚C
Steel Substrate
Zinc Rich Primer – 50µm
Epoxy Intermediate – 100µm
Polyurethane Topcoat – 50µm
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale. Any information given here is for guidance only and no representation or warranty is given as to its potential use.
Zinc silicate technology Rapid overcoating – within 4½ hours Available with various zinc levels to fulfil International Standards
requirements
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale. Any information given here is for guidance only and no representation or warranty is given as to its potential use.
Zinc primers
Often, specifications for zinc primers will be guided by the following industry standards, which set levels of zinc dust in the dried film:
Standard Zinc Level
SSPC Paint 20 Standard
Level 1 ≥85%
Level 2 ≥77% <85%
Level 3 ≥65% <77%
NORSOK M501 ≥80%
ISO 12944 ≥80%
ASTM D520 – zinc dust should contain >94% zinc metal
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale. Any information given here is for guidance only and no representation or warranty is given as to its potential use.
Micaceous Iron Oxide - MIO
MIO is a lamella type (flake like) form of iron oxide which is insoluble in water, organic solvents and alkalis
When incorporated into the coating dry film, its lamella type shape aligns itself parallel to the substrate providing a barrier of overlapping flakes
This barrier prevents the ingress of water, oxygen and ions and thus seriously slows down the corrosion of steel
Steel Substrate
MIOflakes
MIO Flakes
Dry
Fil
m
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale. Any information given here is for guidance only and no representation or warranty is given as to its potential use.
Barrier Pigments – MIO - micaceous iron oxide
STEEL SUBSTRATE
Pigment
Conventional “spherical” Barrier Pigmentation
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale. Any information given here is for guidance only and no representation or warranty is given as to its potential use.
Role of a Top / Finish Coat
A high quality finish and vibrant colours are important for any structure. The main function of finishes is to resist the damaging effects of the sun
which is normally interpreted in coatings as ultraviolet (UV) resistance as well corrosion protection.
UV resistance is the ability of a finish coat to maintain its colour and gloss level over an extended period of time
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale. Any information given here is for guidance only and no representation or warranty is given as to its potential use.
Durability of Finishes
The Carbon-Carbon (C-C) bonds within traditional “organic” coatings are less resilient than those found in acrylic polysiloxanes
Polysiloxane coatings are significantly more resilient to UV (sunlight) degradation which means much improved cosmetic properties over time in service
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale. Any information given here is for guidance only and no representation or warranty is given as to its potential use.
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale. Any information given here is for guidance only and no representation or warranty is given as to its potential use.
Colour Stability – External Exposure
0
0.5
1
1.5
2
2.5
3
0 2 4 6 8 10 12 14
De
lta E
Months
Epoxy Polysiloxane
Acrylate Polysiloxane
Polyurethane
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale. Any information given here is for guidance only and no representation or warranty is given as to its potential use.
Air separation unit - Germany
New steelwork required a durable, corrosion resistant paint system to protect the steel and keep it looking good for many years.
A 3 coat zinc based system was chosen from International Paint.
The Interzinc 22 primer and Intergard 475HS intermediate give long-term corrosion resistance and the Interthane 990 topcoat provides a long-term cosmetically good finish.
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale. Any information given here is for guidance only and no representation or warranty is given as to its potential use.
Refinery vessel externals
Un-insulated vessel externals coated with Interseal 670 and Interthane 990
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale. Any information given here is for guidance only and no representation or warranty is given as to its potential use.
Maintenance of Tank Externals
In order to reduce the amount of dust created the previous coating on these tanks was removed by hydro blasting.
Surface tolerant Interplus 356 was used to prime the hydro blasted steel followed by epoxy intermediate Interseal 670HS and a top coat of Interthane 990.
The system was roller applied and cured at 0°C allowing application during the winter with no additional heating.
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale. Any information given here is for guidance only and no representation or warranty is given as to its potential use.
Long lasting finish
Vessels at a gas processing plant in the Netherlands coated with Interfine 878
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale. Any information given here is for guidance only and no representation or warranty is given as to its potential use.
2009 – Condensate Separator Container(PEMEX, Mexico)
Interzone 954 was applied while the condenser was operating and damp
The product had a hard drying time of 8 hours
There was no problem with runoff or condensation on the surface
“Power Tool Cleaning” (SSPC- P3) Condensate Separator Vessel
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale. Any information given here is for guidance only and no representation or warranty is given as to its potential use.
2009 – Condensate Separator Container(PEMEX, Mexico)
Application of Interzone 954 on 6” condensate pipe
Application of Interzone 954
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale. Any information given here is for guidance only and no representation or warranty is given as to its potential use.
2007 – Ettrick Sage Hot Tap Project(ExxonMobil, UK)
Hot tap structure (500 ltrs )
- Surface prep: blast Sa2.5 or SSPC-SP6 - Full coat Interzone 954 (450m)
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale. Any information given here is for guidance only and no representation or warranty is given as to its potential use.
2003 – Valves (PEMEX, Mexico) (cont.)
Manually cleaned and washed with fresh water
Two coats of Interzone 954 applied with conventional spray equipment and a brush
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale. Any information given here is for guidance only and no representation or warranty is given as to its potential use.
2003 – Valves (PEMEX, Mexico) (cont.)
Application of Interzone 954 grey
Final appearance of Interzone 954 yellow
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale. Any information given here is for guidance only and no representation or warranty is given as to its potential use.
High TemperatureCoatings
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale. Any information given here is for guidance only and no representation or warranty is given as to its potential use.
High Heat
Product Name Resin Type Maximum Temperature
Intertherm 715* Modified Silicone <100°C
Intertherm 228 Epoxy Phenolic 230°C
Intertherm 875* Silicone-acrylic 260°C
Intertherm 751 CSA Titanium Modified Inorganic Co-Polymer
400°C
Intertherm 50* Silicone 540°C
*For some of these materials where improved corrosion protection is required, the Intertherm products can be applied directly over zinc rich primers (e.g. Interzinc 22)
Certain epoxy-phenolic binder systems are suitable for high temperatures up to the 230°C (446°F) limit, thereafter, alternative ‘inorganic’ binder systems need to be used
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale. Any information given here is for guidance only and no representation or warranty is given as to its potential use.
Durable finish for chimney stacks
New chimney stack operating at this refinery required a high temperature resistant finish.
Interzinc 22 was applied to the grit blasted surface in the workshop and once installed on site Intertherm 50, aluminium silicone was applied.
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale. Any information given here is for guidance only and no representation or warranty is given as to its potential use.
Corrosion UnderInsulation
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale. Any information given here is for guidance only and no representation or warranty is given as to its potential use.
Inorganic Zinc Silicate Coatings
Many engineers strictly follow the NACE RP0198 recommendations, & use IOZ for all high temperature service above 120°C.
BUT … NACE do not recommend the use of Zinc Silicates (or Galvanising) on Carbon Steel under warm, wet Insulation.
“.…Inorganic Zinc Coatings or Galvanising shall not be used under Thermal Insulation in the 50-150°C service temperature range for long term or cyclic service. Zinc provides inadequate resistance in closed, sometimes wet environments.…”
CUI with IOZ Primer
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale. Any information given here is for guidance only and no representation or warranty is given as to its potential use.
After heating to 3x400°C
Intertherm 50 – Cyclic heating to 400°C
Rust Ri 5Cracking Density 5;
Size 3-5
Followed by 12 months
C5M
Visually the coating was in good condition
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale. Any information given here is for guidance only and no representation or warranty is given as to its potential use.
Gas Processing Plant, Austria
Gas processing plant in Austria.
The gas driers are filled with SilicaGel to absorb moisture from the gas.
Equipment cycles from ambient up to over 300˚C in order to drive moisture out of SilicaGel once it is saturated.
Previous zinc silicate and aluminium silicone system had failed.
31
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale. Any information given here is for guidance only and no representation or warranty is given as to its potential use.
CUI Coating Selection
Coating to prevent CUI
New Construction Maintenance
0-200°C 0-400ºC 0-150°C 0-200°C
Blast Sa2½
Intertherm 228 2 x 100μm
Blast Sa2½
Intertherm 751 CSA 1 x 175μm
St2/St3
Interplus 2562 x 80μm
SA 2.5
Intertherm 2282 x 100μm
0-100°C
St2/St3
Interseal 670HS2 x 100μm
0-400ºC
SP11 / SA 2.5
Intertherm 751 CSA
2 x 100μm
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale. Any information given here is for guidance only and no representation or warranty is given as to its potential use.
Interplus 256 – Preventing CUI
Stripper columns were coated with Interplus 256 (aluminium) whilst in service.
The surface temperature was 56°C and 3 coats of Interplus 256 were applied in quick succession to create a total dry film thickness of 150-200µm.
After the coating had cured the insulation was replaced on the stripper columns
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale. Any information given here is for guidance only and no representation or warranty is given as to its potential use.
Intertherm 228 – Case History
Intertherm 228 was applied to the outside of this insulated vessel.
The vessel had been suffering from Corrosion Under Insulation (CUI)
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale. Any information given here is for guidance only and no representation or warranty is given as to its potential use.
Intertherm 751 - Product Properties
Two component
Ambient cure
High build - 1x200μm or 2x125μm
High temperature corrosion resistant coating - 400ºC
Resistant to temperature cycling
Based on Titanium Modified Inorganic Copolymer Technology
Pigmented with Aluminium Flake
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale. Any information given here is for guidance only and no representation or warranty is given as to its potential use.
Temperature Cycle – Ambient to 300°C
Preparation - Garnet Blast Sa2 Roller Application – 2 Coats No Insulation Aluminium Jacket with Perforations for
Protection
Cyclic Pipeline in C5M Environment
Photographs from 1st inspection after 11 months. Inspected again after 28 months and was still in good condition.
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale. Any information given here is for guidance only and no representation or warranty is given as to its potential use.
Following successful trial customer has specified Intertherm 751 CSA for all vessels and pipeline under insulation
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale. Any information given here is for guidance only and no representation or warranty is given as to its potential use.
Propane Treater Unit - Australia
Tem
per
atu
re °
C
Time
260
80
40
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale. Any information given here is for guidance only and no representation or warranty is given as to its potential use.
Propane Treater Unit, Australia
Application October 2005.Grit blast 2.5.Airless Spray Applied. 1x200µm.Total Area 200m².
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale. Any information given here is for guidance only and no representation or warranty is given as to its potential use.
Photographs during inspection after one year in service. Also passed second inspection in October 2007.
Propane Treater Unit, Australia
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale. Any information given here is for guidance only and no representation or warranty is given as to its potential use.
Further inspections have shown 7 years service with no signs of degradation
Propane Treater Unit, Australia
20082011
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale. Any information given here is for guidance only and no representation or warranty is given as to its potential use.
Linings
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale. Any information given here is for guidance only and no representation or warranty is given as to its potential use.
International Paint Linings Offer
44
International Paint have the largest linings range in the market
International paint linings can be use to protect the storage tanks, process vessels, equipment, pipe lines and secondary containment areas.
International Paint linings can protect both steel and concrete substrates from attack by a wide range of aggressive chemicals.
The International Paint Linings Offer includes epoxy, epoxy phenolic, epoxy novolac, vinyl ester, novolac vinyl ester, polyurethane and polyurea/polyurethane hybrid technology.
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale. Any information given here is for guidance only and no representation or warranty is given as to its potential use.
Interline
45
Interline is International Paint’s core linings offer
In the market since 1970s
Mostly epoxy based linings for general internal tank lining use
Widely specified by Oil & Gas Majors and global chemical producers
Range has numerous owner approvals and long track record of success.
Normally used to protect steel storage tanks
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale. Any information given here is for guidance only and no representation or warranty is given as to its potential use.
Interline Product Highlights
46
Interline 850Cost effective, new construction epoxy tank lining. Thin film to offer the lowest cost per square meter in terms of material cost.
Interline 984Multi-purpose epoxy phenolic tank lining. Resistant up to 90°C in constant immersion. Suitable for immersion in hydrocarbons including biofuels. One of the few tank linings approved to EI 1541 making it suitable for EI/JIG Standard 1530 compliant jet fuel storage systems
Interline 984 MatcoteChopped strand reinforced lining system applied by automatic chopper gun and spray equipment. Applies reinforced lining system at faster rates than conventional hand lay systems.
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale. Any information given here is for guidance only and no representation or warranty is given as to its potential use.
Interline Examples
47
Diesel storage tank in South Africa.Lined with Interline 984
Brine tank in Malaysia.Internally lined with Interline 399
Jet Fuel Tank in Turkey.Lined with Interline 850
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale. Any information given here is for guidance only and no representation or warranty is given as to its potential use.
Ceilcote
48
Ceilcote Company founded in 1926
Acquired by International Paint in 2006
Specialists in vinyl ester and novolac vinyl ester resins which can resist the most aggressive chemical environments
Leaders in the protection of Flue Gas De-Sulphurisation plants
Usually used to protect steel and concrete chemical storage tanks and secondary containment areas.
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale. Any information given here is for guidance only and no representation or warranty is given as to its potential use.
Ceilcote Product Highlights
49
Ceilcote Mat Screed SystemsHighly reinforced systems to give high strength and chemical resistance. These hand applied systems give long term chemical resistance, ideal for concrete tanks and secondary containment areas.
Ceilcote CeilLine SystemsThe flexible base layer in the CeilLine systems give crack bridging properties which means that if the concrete moves and cracks after application of the system the topcoat will remain intact and not crack.
Ceilcote 282HBWidely specified in Flue Gas De-Sulphurisation equipment – Ceilcote 282 has excellent high temperature resistance and this high build version can be applied to the correct thickness in 2 coats instead of 3.
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale. Any information given here is for guidance only and no representation or warranty is given as to its potential use.
Ceilcote Examples
50
Secondary Containment Area in Turkey.Lined with Ceilcote 232 Mat Screed
Crystallisers in Jordan.Internally lined with Ceilcote 180
Flue Gas De-Sulphurisation Unit in AustriaLined with Ceilcote 282
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale. Any information given here is for guidance only and no representation or warranty is given as to its potential use.
Enviroline
51
Enviroline Company founded in 1960
Acquired by International Paint in 2008
Specialists in high temperature resistant epoxy novolac linings
Enviroline products offer cost reduction to the asset owner due to quick return to service times and winter cure grades
Specified by many Oil & Gas Majors
Usually used to protect steel storage tanks and process vessels
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale. Any information given here is for guidance only and no representation or warranty is given as to its potential use.
Enviroline Product Highlights
52
Enviroline 376F-60Flake and fibre reinforced spray applied in one thick coat of 1500µm. Does not required any other layers or rollering as traditional reinforced system do.Full cure in 14 hours at 25°C
Enviroline 376F LT SeriesLow Temperature cure grade. Cures down to -7°C. Cure in 3 days at 0°C. Traditional epoxy linings do not cure below 5°C and are not recommended to cure below 10°C.
Enviroline 405HTHigh temperature immersion resistant thick film lining. Can resist up to 120°C in constant immersion. Applied in one thick coat of 500µm. Full cure in 14 hours at 25°C.
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale. Any information given here is for guidance only and no representation or warranty is given as to its potential use.
Enviroline Examples
53
Buried pipeline in USA.Externally lined with Enviroline 376F-30
High temperature process vessel in Italy.Internally lined with Enviroline 405HT
Buried Fuel Tank in USA.Lined with Enviroline
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale. Any information given here is for guidance only and no representation or warranty is given as to its potential use.
Storage Tank Base
Chemical storage tank in the UK required sealing of the gap between tank and tank base.
Intercrete products are used with an elastic reinforcement tape to seal the gap between the tank and the tank base.
The Intercrete system is has good adhesion to both concrete and steel to prevent water entering
The Intercrete system also has good flexibility to allow for differential movement of steel and concrete
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale. Any information given here is for guidance only and no representation or warranty is given as to its potential use.
Tank Base Sealing
Gap between concrete base and steel tank was sealed with an Intercrete system and top coated with Interfine 691.
The system creates a flexible waterproof seal which will allow for the different movement of the steel and concrete
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale. Any information given here is for guidance only and no representation or warranty is given as to its potential use.
Concrete
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale. Any information given here is for guidance only and no representation or warranty is given as to its potential use.
International Paint supply the full range of products and lining to repair and protect concrete containment areas in the Oil & Gas Industry.
The cementitious rebuilding products can be used to repair damaged and degraded concrete.
The linings can be used in areas of continuous immersion, such as storage tanks and also in areas of splash and spill such as secondary containment areas.
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale. Any information given here is for guidance only and no representation or warranty is given as to its potential use.
Intercrete
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale. Any information given here is for guidance only and no representation or warranty is given as to its potential use.
Intercrete
59
Intercrete was launched in 2012
Intercrete are cementitious, water based products
Intercrete products are designed to repair and protect concrete
Intercrete offers an excellent barrier to water along with high compressive strength and adhesion.
No primer required. The products are applied to concrete which is wet with clean water meaning that you do not need to wait for the concrete to dry before applying Intercrete.
Usually used to repair and protect concrete tanks
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale. Any information given here is for guidance only and no representation or warranty is given as to its potential use.
High build structural repair mortar.
80mm in one application to overhead and vertical repairs.
Can be bulked out with stones for deeper holes.
No primer required.
Applied to a water saturated substrate.
Demonstration Video
Intercrete 4801
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale. Any information given here is for guidance only and no representation or warranty is given as to its potential use.
Intercrete 4820
Waterproof protective render, pore filler & fairing coat.
Withstand water pressure up to 10 bar.
Maximum thickness 6mm. Can be feather-edged to 0mm.
Used to fill blow holes etc.
Applied by trowel can be bagged rubbed.
Demonstration Video
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale. Any information given here is for guidance only and no representation or warranty is given as to its potential use.
Intercrete 4840Cementitious coating
Waterproofing cementitious coating Resists 10 bar water pressure (positive and negative) 2mm is equivalent to 100mm concrete cover Flexible withstand thermal expansion and contraction Spray applied for large areas Can be applied to damp and green concrete 25 years track record
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale. Any information given here is for guidance only and no representation or warranty is given as to its potential use.
Secondary Containment area protection
The concrete floor area around tanks containing 31% hydrochloric acid and 33% Sodium hydroxide was protected with Ceilcote 380 primer and Ceilcote 232 novolac vinyl ester chemically resistant lining.
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale. Any information given here is for guidance only and no representation or warranty is given as to its potential use.
Drain Channel SumpOman
This sump in the Mechanical Vapour Compression (MVC) Plant was suffering from attack by oily water from drain channels at a temperature of less than 100˚C
The damaged concrete was primed with Ceilcote 380 concrete primer, rebuilt with paste made of Ceilcote 380 mixed with powder and then coated with Ceilcote 222HT to provide long-term chemical resistance.
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale. Any information given here is for guidance only and no representation or warranty is given as to its potential use.
New Construction Power Station
Flue Gas De-sulphurisation unit at a new build power station in Saudi Arabia.
Ceilcote 242MR was selected to protect the absorber against the high temperature chemical attack.
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale. Any information given here is for guidance only and no representation or warranty is given as to its potential use.
Ceilcote 2000MR
Secondary Containment Area around this sulphuric acid tank was rebuilt and protected with Ceilcote 2000MR
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale. Any information given here is for guidance only and no representation or warranty is given as to its potential use.
67
Ceilcrete
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale. Any information given here is for guidance only and no representation or warranty is given as to its potential use.
Chemical and effluent treatment - Secondary containment
Protection of chemical handling area
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale. Any information given here is for guidance only and no representation or warranty is given as to its potential use.
Ceilcote 2000 CeilLine
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale. Any information given here is for guidance only and no representation or warranty is given as to its potential use.
Transformer Bunds
The client wanted to quickly seal electric transformer bunds to ensure that no leaking was possible and to prevent environmental damage.
One thick coat of Polibrid 705E was applied to the bund and hydro tested the same day
The flexibility of Polibrid allows it to move with the concrete substrate and not crack.
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale. Any information given here is for guidance only and no representation or warranty is given as to its potential use.
Pipelines
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale. Any information given here is for guidance only and no representation or warranty is given as to its potential use.
Internal CoatingsStandard Description Cargo Approved Products Suitable ProductsUK DEF STAN 80-97
Jet Fuel Jet Fuel Interline 850Interline 399Interline 984
MIL-C-4556E Jet Fuel Jet Fuel Interline 850EI 1541 Jet Fuel Jet Fuel Interline 984API RP5L2 Epoxy
FlowcoatsGas Intergard 272
Intergard 2272ISO 15741 Epoxy
FlowcoatsGas Intergard 272
Intergard 2272NSF Potable
Water Approval
Potable Water
Interline 850Interline 925Interline 975
N/A Oil pipeline Sour Oil Interline 984Enviroline 376 FEnviroline 405HT
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale. Any information given here is for guidance only and no representation or warranty is given as to its potential use.
Interzone 485 – Workshop application
Interzone 485 - Ultra high build epoxy applied to the externals of buried pipeline in workshop.
Coating passes BS EN 10289 showing suitability for use in this environment.
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale. Any information given here is for guidance only and no representation or warranty is given as to its potential use.
Application Example –Buried Pipeline
Interzone 485 - Ultra high build epoxy applied to the externals of buried pipeline in the field.
Coating tested to BS EN 10289 showing suitability for use in this environment
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale. Any information given here is for guidance only and no representation or warranty is given as to its potential use.
Application Example –Buried PipelineExternals of this buried natural gas pipeline required re-coating. The contractor recommended Enviroline 376F-30 cured epoxy novolac lining following 3 years successful experience using the product.
The quick cure of the coating allows quick back filling of the pipe and also reduces the good weather window required to apply the coating. This saved the customer money and allowed quick completion of the job.
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale. Any information given here is for guidance only and no representation or warranty is given as to its potential use.
External Coatings
Standard Description Environment Approved Products
Suitable products
ISO 10290 Polyurethane External Coatings
Buried Interzone 1800 (under test)
ISO 10289 Epoxy external coatings
Buried Interzone 485Interzone 1500
Enviroline 376 FEnviroline 405HTInterzone 954
ISO 21809 Field Joints Buried Enviroline 124Interzone 485
ISO 12944 External coatings
Above ground Interzinc 22 / 52Intergard 475HSInterthane 990
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale. Any information given here is for guidance only and no representation or warranty is given as to its potential use.
Interline 925
Interline 925 was used to internally line 26,000 m² of water pipeline in India.
Interline 925 was spray applied using rotating airless spray equipment.
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale. Any information given here is for guidance only and no representation or warranty is given as to its potential use.
Case Histories- Oil & Gas Onshore
Oman Gas Corporation- Pipeline Owner: Oman Gas Corporation Applicator: Jindal Saw Ltd Location: Gujarat Project Finished: 2007 Coating: Epoxy Flowcoat Area: 300,000m2
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale. Any information given here is for guidance only and no representation or warranty is given as to its potential use.
CHARTEK 1709CHARTEK 1709FIREPROOFINGFIREPROOFING
AA real alternative to cement or concrete based fire protectionreal alternative to cement or concrete based fire protection
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale. Any information given here is for guidance only and no representation or warranty is given as to its potential use.
Chartek 1709 Chartek 1709 is epoxy intumescent
fireproofing
It gives protection against oil & gas fires for the onshore hydrocarbon industries
In a fire it forms an insulating layer to protect the steel from extreme heat
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale. Any information given here is for guidance only and no representation or warranty is given as to its potential use.
C1709 gives corrosion protection
Strong, durable material
30 years track record of corrosion protection
Epoxy market leader used by all major operators worldwide
No recorded failure due to the material itself
Fast application: no pins and no metal mesh
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale. Any information given here is for guidance only and no representation or warranty is given as to its potential use.
A real alternative to cementitious fireproofing Concrete/cement fireproofing is porous
Allows corrosion to take place unseen (Corrosion Under Fireproofing)
Requires regular crack repair and maintenance of topcoat
High cost of maintenance gives high lifecycle costs Collapsed sphere due to corrosion
under cementitious PFP
Corrosion of column web
under cementitious PFP
After fire buckling of
steel column ‘protected’ by cementitous
pfp
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale. Any information given here is for guidance only and no representation or warranty is given as to its potential use.
Summary
International Paint have the complete product offer for the Oil & Gas Industry
International Paint have full range of traditional paint systems to protect structural steel and offer long-term performance.
Specialised products can be used to solve most difficult issues on site.
International Paint provide high levels of service to both owners and applicators whilst adhering to strict business principles practices from Akzo Nobel.