Contents
General dataApplications page 4Type key page 4Performance range, HS page 4Pumped liquids page 5Operating conditions page 5Motor page 5Pump page 5Materials page 5
Technical dataDimensions page 6Dimensional sketch, HS 1/2 - 3 hp page 6Dimensional sketch, HS 5 - 7 1/2 hp page 6Performance curves/electrical data, HS 100 page 7Performance curves/electrical data, HS 125 page 8Performance curves/electrical data, HS 150 page 9
2
Mission
GBJ - Bjerringbro, Denmark
GMU - Fresno, California GPU - Olathe, Kansas
GMX - Monterrey, Mexico GPA - Allentown, Pennsylvania GCA - Oakville, Ontario, Canada
- to successfully develop, produce, and sell high quality pumps and pumping systems worldwide, contributing to a better quality of life and healthier environment
• One of the 3 largest pump companies in the world
• World headquarters in Denmark
• North American headquarters in Kansas City - Manufacturing in Fresno, California
• 60 companies in 40 countries
• More than 10 million pumps produced annually worldwide
• North American companies operating in USA, Canada and Mexico
• Continuous reinvestment in growth and development enables the company to
BE responsible, THINK ahead, and INNOVATE
3
4
General data
HSApplicationsThe HS range of compact, horizontal, centrifugal pumpsis designed for small domestic and industrial watersupply systems.
Applications include:
• Liquid transfer:
Transfer and circulation of liquids within light indus-try and farming.
• Pressure boosting
• Air conditioning
• Domestic water supply
• Water fountains
• Cooling systems
• Air-conditioning systems
• Light irrigation
In addition to this, the HS range is suitable for incorpora-tion in specialized OEM equipment.
(OEM = Original Equipment Manufacturer)
Type key
HS
Performance range, HS
Example HS 125 1515
Pump type
Discharge size (/100)
Nominal HP for ODP motor (/10)
Nominal HP for TEFC motor (/10)
TK0
2 0
150
330
3
0 20 40 60 80 100 120 140 Q [US GPM]
0
20
40
60
80
100
120
140
160
H [ft]
0 5 10 15 20 25 30 35 Q [m³/h]
0
10
20
30
40
50
H [m]
HS60 Hz
3450 RPM
HS 100
HS 125
HS 150
General data
HSPumped liquidsThin, clean, non-aggressive and non-explosive liquidswithout solid particles or fibers.
Operating conditionsLiquid temp.: -5°F to +180°F (-20°C to +82°C)
continuous
-5°F to +211°F (-20°C to +99°C)intermittent
Max. ambient temp.: +104°F (+40°C)
Max. operating press.: 125 psi (8.6 bar)
Minimum inlet press.: According to the NPSHR curveplus a safety margin of 3 ft.
Maximum inlet press.: Limited by maximum operating pressure.
MotorThe pump is fitted with a heavy-duty, Grundfos-speci-fied motor.
Electrical data
Single-phase motors have built-in thermal overloadprotection. Three-phase motors must be connected to amotor starter according to local regulations.
Direction of rotation: Clockwise from motor end.
PumpThe HS pumps are non-self-priming, single-stage, hori-zontal centrifugal pumps with mechanical shaft sealand close coupled pump/motor shaft. The pumps havean axial suction port and radial discharge port and aremounted on a base plate.
Buna-N O-rings are standard.
For pipe connections see table below.
Materials, HS
Mounting designation NEMA
Insulation class F
Efficiency class Standard Efficiency
EPAct - on request
High Efficiency - on request
Enclosure class ODP - Open Drip Proof
TEFC - Totally Enclosed Fan Cooled
60 Hz Standard voltages 1 x 115/208-230V
3 x 208-230/460V
Approvals Motors are rated.®
Connections HS 100 HS 125 HS 150
Axial suction port 1 1/4” NPT 1 1/2” NPT 2” NPT
Radial discharge port 1” NPT 1 1/4” NPT 1 1/2” NPT
Description Material
Pump housing, motor stool,base plate
Cast iron
Impeller Brass
Pump shaftHS 100, HS 125 Brass
HS 150 AISI 416 SS
Shaft sealCarbon/ceramic with Buna-Nelastomer and stainless steel parts (FKM elastomers optional)
5
6
Performance curves
HS 100TK0
1 0
100
29
03
0 5 10 15 20 25 30 35 40 45 Q [US GPM]
0
5
10
15
20
25
30
35
40
45
50
55
60
65
H [ft]
0 2 4 6 8 10 Q [m³/h]
0
2
4
6
8
10
12
14
16
18
20
H [m]
HS 10060 Hz
3450 RPM
0707
0505
47%
46%
35%
40%
45%
40%
45%
45%
40%
35%
35%
40%
45%
0 5 10 15 20 25 30 35 40 45 Q [US GPM]
0.0
0.2
0.4
0.6
0.8[hp]P2
0.0
0.2
0.4
P2[kW]
0707
0505
0 5 10 15 20 25 30 35 40 45 Q [US GPM]
0
10
20
30
40
NPSH[ft]
0
5
10
H [m] 0707 0505
NPSHR
Technical data
HS 100Dimensional sketch, HS 100
Dimensions, HS 100
Electrical data, HS 100
TEFC voltage is: *115/230
Pump type HP PHNEMAFrame
Size
Suc. Size [in]
Dis. Size [in]
Open drip proof (ODP) motor Totally enclosed fan cooled (TEFC) motorShipvol.
[ft3]A [in] B [in] C [in]Ship wt.
[lbs]A [in] B [in] C [in]
Ship wt.
[lbs]
HS 100 0505 1/2 1 56C 1 1/4 1 4 3/8 9 3/8 4 3/4 47 5 9 3/8 5 53 1.7
3 - 9 1/4 4 3/8 50 - 9 3/8 5 47 1.7
HS 100 0707 3/4 1 56C 1 1/4 1 5 11 4 7/8 50 5 1/8 10 5 57 1.7
3 - 9 1/2 4 3/8 51 - 9 3/8 5 50 1.7
DISCHARGESUCTION
2 1/4
8 3/4
4 3/4
B 5 7/8
5 7/8 4 5/8 4 7/83 7/8
3 3/84 1/2C
A
Pump type HP PH Voltage
Open drip proof (ODP) motor Totally enclosed fan cooled (TEFC) motor
S.F.Full load
current [A]S.F. current
[A]Start current
[A]S.F.
Full load current
[A]
S.F. current [A]
Start current [A]
HS 100 0505 1/2 1 115/208-230* 1.25 7.2/4.0-3.6 8.0/4.4-4.0 30/16.6-15 1.6 7.4/4.1-3.7 9.8/5.2-4.9 39/21.6-19.5
3 208-230/460 1.25 2.1-2.0/1.0 2.6-2.4/1.2 13.3-12/6.0 1.25 2.1-2.0/1.0 2.6-2.4/1.2 13.3-12/6.0
HS 100 0707 3/4 1 115/208-230* 1.25 9.6/5.3-4.8 11.4/6.3-5.7 56/31-28 1.25 9.6/4.8 11.4/5.7 56/28
3 208-230/460 1.25 2.7-2.6/1.3 3.1-3.0/1.5 16.8-15.2/7.6 1.25 2.7-2.6/1.3 3.1-3.0/1.5 16.8-15.2/7.6
7
8
HS 125
Performance curvesTK0
1 0
125
290
3
0 10 20 30 40 50 60 70 Q [US GPM]
0
10
20
30
40
50
60
70
80
90
H [ft]
0 5 10 15 Q [m³/h]
0
5
10
15
20
25
H [m]
HS 12560 Hz
3450 RPM
1010
1515
2020
66%
61%
60%
60%55%
40%
50%
60%
60%
55%65%
55%
45%
50%
45%
55%
55%
40%
50%
65%
60%
55%
50%45%
0 10 20 30 40 50 60 70 Q [US GPM]
0.0
0.5
1.0
1.5
[hp]P2
0.0
0.5
1.0
P2[kW]
1515 1010
2020
0 10 20 30 40 50 60 70 Q [US GPM]
0
10
20
NPSH[ft]
0
5
H [m] 20201515
1010 NPSHR
HS 125
Technical dataDimensional sketch, HS 125
Dimensions, HS 125
Electrical data, HS 125
TEFC voltage is: *115/230
Pump type HP PHNEMAFrame
Size
Suc. Size [in]
Dis. Size [in]
Open drip proof (ODP) motorTotally enclosed fan cooled (TEFC)
motor Shipvol.
[ft3]A [in] B [in] C [in]Ship wt.
[lbs]A [in] B [in] C [in]
Ship wt.
[lbs]
HS 125 1010 1 1 56C 1 1/2 1 1/4 5 5/8 11 1/4 5 5/8 52 5 5/8 11 1/4 5 3/4 68 1.7
3 - 9 1/2 5 5/8 51 - 10 1/4 5 3/4 50 1.7
HS 125 1515 1 1/2 1 56C 1 1/2 1 1/4 5 1/2 11 3/4 5 5/8 54 5 5/8 11 3/4 5 3/4 70 1.7
3 - 10 3/4 5 5/8 55 - 10 3/4 5 3/4 57 1.7
HS 125 2020 2 1 56C 1 1/2 1 1/4 5 1/2 11 3/4 5 5/8 37 5 5/8 12 5/8 5 3/4 77 1.7
3 - 10 3/4 5 5/8 66 - 11 3/4 5 3/4 66 1.7
Pump type HP PH Voltage
Open drip proof (ODP) motor Totally enclosed fan cooled (TEFC) motor
S.F.Full load
current [A]S.F. current
[A]Start current
[A]S.F.
Full load current
[A]
S.F. current [A]
Start current [A]
HS 125 1010 1 1 115/208-230 1.4 10/5.5-5.0 15/8.0-7.5 85/47-42.5 1.25 12/6.0 14.4/7.2 77/38.5
3 208-230/460 1.25 3.4-3.2/1.6 3.8-3.6/1.8 19.5-17.6/8.9 1.25 3.4-3.2/1.6 3.8-3.6/1.8 19.7-17.8/8.9
HS 125 1515 1 1/2 1 115/208-230* 1.15 18/10-9 19.7/10.7-9.7 121/66.8-60.4 1.3 17/9.5-8.6 20.4/11.3-10.2 106/58.6-53
3 208-230/460 1.15 5.0-4.6/2.3 5.4-5.0/2.5 35.4-32/16 1.15 5.0-4.6/2.3 5.4-5.2/2.6 35.4-32/16
HS 125 2020 2 1 115/208-230* 1.15 24/13.3-12 27.6/15.3-13.8 160/88.5-80 1.15 23/11.5 25.4/12.7 156/78
3 208-230/460 1.15 5.9-5.6/2.8 6.7-6.4/3.2 40.9-37/18.5 1.15 5.7-5.4/2.7 6.5-6.2/3.1 38.7-35/17.5
DISCHARGESUCTION
2 1/4
8 3/4
4 3/4
B 5 7/8
5 7/8 4 5/8 4 7/83 7/8
3 3/84 1/2C
A
9
HS 150
10
Performance curves
TK0
1 0
150
29
03
0 20 40 60 80 100 120 140 160 Q [US GPM]
0
20
40
60
80
100
120
140
160
H [ft]
0 5 10 15 20 25 30 35 40 Q [m³/h]
0
10
20
30
40
50
H [m]
HS 15060 Hz
3450 RPM
2020
3030
5050
7575
65%
55%
66%
62%
60%
45%
40%
50%
60%
60%
55%
50%
50%
50%
60%
45%
45%
50%
45%
45%
45%
55%
55%
40%
40%
50%
60%
55%
55%50%
65%
65%
60%55%
50%45%
0 20 40 60 80 100 120 140 160 Q [US GPM]
0
2
4
6
[hp]P2
0
2
4
P2[kW]
2020 3030
5050
7575
0 20 40 60 80 100 120 140 160 Q [US GPM]
0
10
20
NPSH[ft]
0
5
H [m]
2020 3030
5050
7575
NPSHR
HS 150
Technical dataDimensional sketch, HS 150 Large Dimensional sketch, HS 150 Small
Dimensions, HS 150
Electrical data, HS 150
TEFC voltage is: *115/230, **115/208-230, ***230
DISCHARGESUCTION
B
126 1/2
5
8 5/87 1/2
C 5 1/83 7/82 1/4
A
9 1/4
8 1/2
DISCHARGESUCTION
2 1/4
9
4 3/4
B 6 1/8
5 7/8 4 7/8 4 7/83 7/8
3 3/85 1/8C
A
Pump type HP PHNEMAFrame
Size
Suc. Size [in]
Dis. Size [in]
Open drip proof (ODP) motorTotally enclosed fan cooled (TEFC)
motor Shipvol.
[ft3]A [in] B [in] C [in]Ship wt.
[lbs]A [in] B [in] C [in]
Ship wt.
[lbs]
HS 150 2020 2 1 56C 2 1 1/2 5 1/2 11 3/4 5 5/8 37 5 5/8 12 5/8 5 3/4 83 1.7
3 - 10 3/4 5 5/8 66 - 11 3/4 5 3/4 72 1.7
HS 150 3030 3 1 56C 2 1 1/2 5 1/2 12 1/8 5 1/4 85 6 1/4 13 6 103 1.7
3 - 11 1/4 5 1/8 78 - 12 1/8 5 3/4 81 1.7
HS 150 5050 5 1 184TC 2 1 1/2 6 5/8 12 1/4 6 3/4 116 6 5/8 15 1/4 6 130 1.7
3 182TC - 12 1/4 6 3/4 113 - 13 3/4 6 7/8 115 1.7
HS 150 7575 7 1/2 3 184TC 2 1 1/2 - 12 1/4 6 3/4 118 - 15 1/4 6 7/8 129 1.7
Pump type HP PH Voltage
Open drip proof (ODP) motor Totally enclosed fan cooled (TEFC) motor
S.F.Full load
current [A]S.F. current
[A]Start current
[A]S.F.
Full load current
[A]
S.F. current [A]
Start current [A]
HS 150 2020 2 1 115/208-230* 1.15 24/13.3-12 27.6/15.3-13.8 160/88.5-80 1.15 23/11.5 25.4/12.7 156/78
3 208-230/460 1.15 5.9-5.6/2.8 6.7-6.4/3.2 40.9-37/18.5 1.15 5.7-5.4/2.7 6.5-6.2/3.1 38.7-35/17.5
HS 150 3030 3 1 230** 1.15 13 14.8 108 1.15 30/16.5-15 32.2/17.8-16.1 172/95.1-86
3 208-230/460 1.15 8.4-8.0/4.0 9.2-8.7/4.4 66.3-60/30 1.15 7.8-7.4/3.7 9.5-8.6/4.3 59.7-54/27
HS 150 5050 5 1 208-230*** 1.15 24-23 30.1-27.2 138-125 1.15 21 24.2 124
3 208-230/430 1.15 13.1-11.5/5.7 15.3-13.8/6.9 106-96/48 1.15 13-12/6.0 14.8-13.4/6.7 123.8-112/56
HS 150 75757 1/2 3 208-230/460 1.15 19-18/9.0
22.3-20.2/10.1
168-152/76 1.15 18.5-17.4/8.7 21.7-19.6/9.8207.9-188/
94
11
13
Company name:Prepared by:
Phone number: ( ) -Fax number: ( ) -
Horizontal Single-stage Centrifugal Pumps Date: Page 1 of:Quote number:
Project title: Client name:Reference number: Client number:
Client contact: Client phone no: ( ) -
For: Unit:Site: Service:
Address: City: State: Zip Code:
max. norm. min. Fluid type:Capacity (gpm) rated max. norm.Suction Pressure (psig) Fluid Temperature (°F)Discharge Pressure (psig) at designated temperatureDifferential Head (ft) Specific GravityHydraulic Power (hp) Vapor Pressure (psia)at designated capacity Viscosity (cp)NPSH Available (ft) Fluid ph: Chlorides (ppm):
Hazardous: Flammable:Service Other:
Continuous: Intermittent (starts/day): Corrosion/Errosion caused by:% Solids: Max. particle size (in):
Model Information from Type Key and Codes:Quantity Required:
Minimum required flow: NPSH required at duty point:Product Guide additional information pages
Materials page number: Performance curve page number:Technical data page number: Motor data page number:
HP: Phase: Voltage: Enclosure:
Example: HS 125 1015
HS
Location Information
Client Information
Additional Information
Application Information
Pump Information
Motor Information
Pumped FluidOperating Conditions
Submittal Data Sheet
155
HSHorizontal, single-stage, non-self-priming, centrifugal pump with axial suction port and radial discharge port.
The compact unit has maintenance-free mechanical shaft seal and a close-coupled motor/pump shaft.
Pump and motor are mounted on a common baseplate and the tangentia discharge can be rotated to any of four positions.
The motor is a ______-phase motor.
Technical:Rated flow: _______________ GPMRated head: _______________ FeetMinimum liquid temperature: _______________ °FMaximum liquid temperature: _______________ °FType of shaft seal: _______________
Materials:Material, pump housing: Cast ironMaterial, impeller: BronzeMaterial, shaft: _______________Material, seal metal: Stainless Steel
- seal face: Carbon- seal face Ceramic- seal elastomer: _______________
Installation:Minimum ambient temperature: _______________ °FMaximum ambient temperature: _______________ °FMaximum operating pressure: _______________ PSIMax. pressure at stated temp.: _______________ PSI/°FSize, pipe connection: _______________ Suction/Discharge ” NPT
Electrical data:Rated power (P2): _______________ HPFrequency: _______________ HzRated voltage: _______________ VRated current: _______________ A
Service factor: _______________ Rated speed: _______________ RPMEnclosure class: _______________ Insulation class: F
Additional:Gross weight: _______________ Lbs.Shipping volume: _______________ ft3
/_______________ Suction/Discharge ” NPT//_______________ Suction/Discharge ” NPT
Quotation Text
Subject to alterations.
Being responsible is our foundationThinking ahead makes it possible
Innovation is the essence
Being responsible is our foundationThinking ahead makes it possible
Innovation is the essence
GRUNDFOS Pumps Corporation 17100 West 118th TerraceOlathe, Kansas 66061Phone: 913 227 3400Fax: 913 227 3500
GRUNDFOS Canada Inc. 2941 Brighton Road Oakville, Ontario Canada L6H 6C9Phone: 905 829 9533 Fax: 905 829 9512
Bombas GRUNDFOS de Mexico S.A. de C.V. Boulevard TLC No. 15Parque Industrial Stiva AeropuertoApodaca, N.L. Mexico 66600Phone: 52 81 8144 4000 Fax: 52 81 8144 4010www.grundfos.com
Back.fm Page 83 Friday, September 6, 2002 4:53 PM
L-HS-PG-001 11/03PRINTED IN USA