Download - HexaLED 1. 2 SPECIFICATIONS Certifications Damp location rated cULus certified Energy Star 3
![Page 1: HexaLED 1. 2 SPECIFICATIONS Certifications Damp location rated cULus certified Energy Star 3](https://reader035.vdocuments.mx/reader035/viewer/2022070400/56649e2b5503460f94b191e0/html5/thumbnails/1.jpg)
1
HexaLED
![Page 2: HexaLED 1. 2 SPECIFICATIONS Certifications Damp location rated cULus certified Energy Star 3](https://reader035.vdocuments.mx/reader035/viewer/2022070400/56649e2b5503460f94b191e0/html5/thumbnails/2.jpg)
2
![Page 3: HexaLED 1. 2 SPECIFICATIONS Certifications Damp location rated cULus certified Energy Star 3](https://reader035.vdocuments.mx/reader035/viewer/2022070400/56649e2b5503460f94b191e0/html5/thumbnails/3.jpg)
3
SPECIFICATIONS
Certifications• Damp location rated• cULus certified• Energy Star
![Page 4: HexaLED 1. 2 SPECIFICATIONS Certifications Damp location rated cULus certified Energy Star 3](https://reader035.vdocuments.mx/reader035/viewer/2022070400/56649e2b5503460f94b191e0/html5/thumbnails/4.jpg)
4
SPECIFICATIONS
FEATURES• Power options: 22w, 30w or 40w• 1700 to 3100 lumens • CCT: 3000K / 3500K / 4000K• 80CRI (3000°k offered with a 90CRI option)• L70 @ 50 000 hrs• 15°, 21° & 46° beams
![Page 5: HexaLED 1. 2 SPECIFICATIONS Certifications Damp location rated cULus certified Energy Star 3](https://reader035.vdocuments.mx/reader035/viewer/2022070400/56649e2b5503460f94b191e0/html5/thumbnails/5.jpg)
5
SPECIFICATIONS
DIMMING• 3 options:
ELV reverse phase 3-wire dimmers (trailing edge) Often used in residential application but also on some commercial jobs.
0-10V sinking control same as fluorescent dimming ballastsSome high-end residential jobs will call for that but mostly commercial ones
Lutron Hi-Lume A-Series LED driver with ECOsystem Control / 3-wire (CCR)
CCR stands for Constant Current Reduction - Sometimes this type of dimming is referred to as “Analog Dimming”. Instead of phase cutting, the driver reduces the output current.
![Page 6: HexaLED 1. 2 SPECIFICATIONS Certifications Damp location rated cULus certified Energy Star 3](https://reader035.vdocuments.mx/reader035/viewer/2022070400/56649e2b5503460f94b191e0/html5/thumbnails/6.jpg)
6
SPECIFICATIONS
DIMMINGLutron Hi-Lume A-Series LED driver with ECOsystem Control / 3-wire (CCR)
Applications suitable for CCR :
Applications that may have strict Electro-magnetic interferences(EMI) requirements, such as medical suites.
Applications with high motion activity or rotating machinery. No stroboscopic effect at all.
![Page 7: HexaLED 1. 2 SPECIFICATIONS Certifications Damp location rated cULus certified Energy Star 3](https://reader035.vdocuments.mx/reader035/viewer/2022070400/56649e2b5503460f94b191e0/html5/thumbnails/7.jpg)
7
SPECIFICATIONSLutron Hi-Lume A-Series LED driver with ECOsystem Control / 3-wire (CCR)
![Page 8: HexaLED 1. 2 SPECIFICATIONS Certifications Damp location rated cULus certified Energy Star 3](https://reader035.vdocuments.mx/reader035/viewer/2022070400/56649e2b5503460f94b191e0/html5/thumbnails/8.jpg)
8
Trim FinishWHITE -01
MATTE WHITE -11
BLACK -02
METALLIC GREY -15
![Page 9: HexaLED 1. 2 SPECIFICATIONS Certifications Damp location rated cULus certified Energy Star 3](https://reader035.vdocuments.mx/reader035/viewer/2022070400/56649e2b5503460f94b191e0/html5/thumbnails/9.jpg)
9
New Construction HousingJunction Box :
Max of 10 #14 or 8 #12AWG
branch circuit conductors
3 Driver options for 3 types of dimming: • Electronic Low Voltage (ELV)• 0-10V (Sinking Control)• CCR (Hi-Lume Ecosystem addressable)
Very high quality injected aluminumheat-sink ensuring
maximum heat dissipation. 18“ BX conduit
Adjustable mounting bars(10" to 24 ½“).
![Page 10: HexaLED 1. 2 SPECIFICATIONS Certifications Damp location rated cULus certified Energy Star 3](https://reader035.vdocuments.mx/reader035/viewer/2022070400/56649e2b5503460f94b191e0/html5/thumbnails/10.jpg)
10
Dimensions
![Page 11: HexaLED 1. 2 SPECIFICATIONS Certifications Damp location rated cULus certified Energy Star 3](https://reader035.vdocuments.mx/reader035/viewer/2022070400/56649e2b5503460f94b191e0/html5/thumbnails/11.jpg)
11
Applications
• Retail Stores• Restaurants• Lobbies• Hotels• Office Spaces• Conference Rooms• Museums• Art Galleries
• Showroom• Public Areas• Other commercial interiors• High Soffits (MG treatment is highly recommended)
Suitable for commercial, retail & institutional applications
![Page 12: HexaLED 1. 2 SPECIFICATIONS Certifications Damp location rated cULus certified Energy Star 3](https://reader035.vdocuments.mx/reader035/viewer/2022070400/56649e2b5503460f94b191e0/html5/thumbnails/12.jpg)
12
Housing and Trim codification
![Page 13: HexaLED 1. 2 SPECIFICATIONS Certifications Damp location rated cULus certified Energy Star 3](https://reader035.vdocuments.mx/reader035/viewer/2022070400/56649e2b5503460f94b191e0/html5/thumbnails/13.jpg)
13
Ordering guide on the Web
![Page 14: HexaLED 1. 2 SPECIFICATIONS Certifications Damp location rated cULus certified Energy Star 3](https://reader035.vdocuments.mx/reader035/viewer/2022070400/56649e2b5503460f94b191e0/html5/thumbnails/14.jpg)
14
Photometric Data
* 30' ceiling would result in a Ø7.5' beam of 30Fc illuminance at the floor level
Lets use the HexaLED 40W 4000k spot beam.
![Page 15: HexaLED 1. 2 SPECIFICATIONS Certifications Damp location rated cULus certified Energy Star 3](https://reader035.vdocuments.mx/reader035/viewer/2022070400/56649e2b5503460f94b191e0/html5/thumbnails/15.jpg)
15
Application #1Client needs accent lighting in the middle of a 30' high wall.
HexaLED 40W / 4000k@80CRI / 14° spot beam :
This is a screenshot from GE Light*Beams free program
http://www.gelighting.com/LightingWeb/na/images/lb_setup.exe
![Page 16: HexaLED 1. 2 SPECIFICATIONS Certifications Damp location rated cULus certified Energy Star 3](https://reader035.vdocuments.mx/reader035/viewer/2022070400/56649e2b5503460f94b191e0/html5/thumbnails/16.jpg)
16
Application #2Client needs a task light level on a 30" high work plane in a 20'x30'x12' room.
HexaLED 40W / 3000k@80CRI / 44° beam :
Copyright 2011-2014, Acuity Brands Lighting, Inc. Visual Interior Tool version: 2.0.3.0
http://www.visual-3d.com/tools/interior/
![Page 17: HexaLED 1. 2 SPECIFICATIONS Certifications Damp location rated cULus certified Energy Star 3](https://reader035.vdocuments.mx/reader035/viewer/2022070400/56649e2b5503460f94b191e0/html5/thumbnails/17.jpg)
NEXT WEBINAR
Next Webinar will take place on March 25th17
![Page 18: HexaLED 1. 2 SPECIFICATIONS Certifications Damp location rated cULus certified Energy Star 3](https://reader035.vdocuments.mx/reader035/viewer/2022070400/56649e2b5503460f94b191e0/html5/thumbnails/18.jpg)
QUESTION PERIOD
Next Webinar will take place on March 25th18