-
GRUNDFOS DATA BOOKLET
Accessories for dosing pumps
-
Table of contents
2
Accessories for dosing pumps
1. Accessories for small dosing pumps up to 60 l/h 3Accessories overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Installation kits for dosing pumps. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4Cables and plugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5E-box for SMART digital S DDA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6Hoses. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7Foot valves FV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8Rigid suction lances RSL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9Injection units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13Multi-function valves, pressure relief valves, pressure loading valves. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15Pump connection kits and inlay kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18Adapters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Dosing tanks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21Water meter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
2. Accessories for medium-sized dosing pumps up to 460 l/h 26Accessories overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26Cables and plugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27Hoses. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28Foot valves FV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29Rigid suction lances RSL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30Level-control units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33Injection units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34Pressure relief valves PRV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35Pressure loading valves PLV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36Pressure valves PV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37Pulsation dampers and calibration columns . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38Pump connection kits and inlay kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47Electric stirrers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48Withdrawal devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49Adapters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50Wall or tank mounting assembly for SMART Digital XL DDA/DDE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51Tank accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
3. Accessories for large dosing pumps of more than 460 l/h 52Overview of a dosing system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52Cables and plugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53Diaphragm leakage sensor for DME pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54Hoses. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54Foot valves. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55Rigid suction lines for stationary tanks. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56Injection units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57Pressure relief valves. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59Pressure loading valves. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61Pulsation dampers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
4. Grundfos Product Center 69
-
Acc
esso
ries
for
smal
l dos
ing
pum
ps u
p to
60
l/h
3
Accessories for dosing pumps 1
1. Accessories for small dosing pumps up to 60 l/h
Accessories overviewGrundfos offer a comprehensive range of accessories covering every need when dosing with Grundfos pumps.
Fig. 1 Dosing pump with accessories
TM04
159
9 03
12
100%
P S
Hoses see page 7Injection units see pages 13, 14
Multi-function valves, pressure loading valves, pressure relief valves, pressure valves, see pages 15, 16, 17
Example: SMART Digital dosing pump
Installation kits see page 4
Pump connection kits and inlay kits see page 18
Adapters see page 19
T-pieces see page 20
Dosing tanks see page 21
Handheld mixer see page 24
Drain valves see page 24
Foot valves and rigid suction lances, see pages 8, 9
E-box see page 6
Cables see page 5
-
Accessories for sm
all dosing pumps up to 60 l/h
4
Accessories for dosing pumps1
Installation kits for dosing pumpsAn installation kit includes the following parts:• Injection unit with spring-loaded non-return valve
(see page 13)• PE outlet hose, 6 m• PVC inlet hose, 2 m• PVC deaeration hose, 2 m• PE foot valve with strainer and weight, without or
with level indication (see page 8).Fig. 2 Installation kit with foot valve without level
indication
Fig. 3 Installation kit with foot valve with level indication
Technical data
* Viscosity similar to water
TM04
160
0 03
12TM
04 8
469
0512
Max. flow rate*[l/h]
Max. pressure[bar]
Size Material of injection unit Product number
Inlet / outlet hose[mm]
Deaeration hose[mm]
Body Gasket BallFoot valve
without level indication
Foot valve with level indication
7.5 13 4/6 4/6
PPFKM Ceramic 95730440 95730464
EPDM Ceramic 95730441 95730465
PVCFKM Ceramic 95730442 95730466
EPDM Ceramic 95730443 95730467PTFE Ceramic 95730444 95730468
PVDFFKM Ceramic 95730445 95730469
EPDM Ceramic 95730446 95730470PTFE Ceramic 95730447 95730471
30 12 6/9 4/6
PPFKM Ceramic 95730448 95730472
EPDM Ceramic 95730449 95730473
PVCFKM Ceramic 95730450 95730474
EPDM Ceramic 95730451 95730475PTFE Ceramic 95730452 95730476
PVDFFKM Ceramic 95730453 95730477
EPDM Ceramic 95730454 95730478PTFE Ceramic 95730455 95730479
60 9 9/12 4/6
PPFKM Ceramic 95730456 95730480
EPDM Ceramic 95730457 95730481
PVCFKM Ceramic 95730458 95730482
EPDM Ceramic 95730459 95730483PTFE Ceramic 95730460 95730484
PVDFFKM Ceramic 95730461 95730485
EPDM Ceramic 95730462 95730486PTFE Ceramic 95730463 95730487
-
Acc
esso
ries
for
smal
l dos
ing
pum
ps u
p to
60
l/h
5
Accessories for dosing pumps 1
Cables and plugsThe listed cables and plugs are suitable for the connection of a pump to external control devices, such as process controllers, flow meters, start/stop contacts and level sensors.
Fig. 4 Cable and plug
Technical data• Cable material: PVC, 0.34 mm2
• Plug size: M 12
TM04
826
7 04
11
Socket Application Pins Plug type Cable length[m] Product number
Input Analog pulseExternal stop 4Straight
2 966090145 96609016
No cable 96698715Angled 2 96693246
Input Low levelEmpty tank 4 Straight No cable 96698715
Output Analog 5Straight
2 966329215 96632922
No cable 96609031Angled 2 96699697
Output Relay 1Relay 2 4Straight
2 966090175 96609019
No cable 96696198Angled 2 96698716
-
Accessories for sm
all dosing pumps up to 60 l/h
6
Accessories for dosing pumps1
E-box for SMART digital S DDAThe Grundfos E-box (Extension Box) is a Plug & Play fieldbus communication interface for the integration of SMART Digital S DDA dosing pumps (up to 30 l/h) into a fieldbus network. Fieldbus communication allows to use the DDA dosing pump in industrial automation systems (PLC; SCADA), where advanced remote control and monitoring functions are required:• Remote control of all settings, such as operation
mode, flow rate, etc.• Remote monitoring of all parameters, such as
measured flow, pressure, faults with cause, etc.The E-box contains a standard Grundfos CIM communication interface module for data transmission between a fieldbus network and a Grundfos pump.SMART digital S DDA dosing pumps can be retrofitted easily with the E-box: it is simply placed between the pump and the mounting plate. The E-box has a connecting cable that is plugged directly into the pump.
Fig. 5 E-box
Dimensions
Fig. 6 E-box, dimensions
General data
E-box 150 Profibus DP
E-box 200 Modbus RTU
E-box 500 Ethernet
Description Product numberE-box 150 Profibus DP 97513994E-box 200 Modbus RTU 98563350E-box 500 Ethernet 99171932
TM04
845
5 03
12TM
04 8
454
0312
Supply voltage 30 VDC, ± 10 % (via M 12 plug of DDA)Max. power consumption 5 WMax. relative humidity 96 %Pollution degree 2
Enclosure classIP65 according to IEC 60529NEMA 4X
Electrical safety class 3Min./max. ambient temperature 0/45 °C
Approvals CE, CB, CSA-US, RCMWeight 0.4 kg
GENIbus connection(E-box to pump)
Data protocol GENIbusGENIbus connection type Three-wire RS-485Transmission speed 9.6 kbits/sCable length 160 mm
Required pump software for retrofitting V2.5 or higher
Profibus implementation class DP-V0
Connection type RS-485, two-wire (lines: A, B)
Recommended cable typeScreened, double-twisted pairconductor cross-section: 0.34 - 1 mm2AWG: 22-17
Maximum cable length 100 m at 12000 kbits/s1200 m at 9.6 kbits/sSlave address (set in DDA display) 1-126
Line termination (set via DIP switches) On/off
Supported data rates 9.6 - 12000 kbits/sGSD file for system integration:http://net.grundfos.com/qr/i/GRUN0CD9
Required pump software for retrofitting V2.5 or higher
Connection type RS-485, two-wire + common
Recommended cable type
Screened, twisted pairconductor cross-section:0.20 - 0.25 mm2AWG: 24-23
Maximum cable length 1200 mSlave address (set in DDA display) 1-247
Line termination (set via DIP switches) On/off
Supported data rates 9600 / 19200 / 38400 bits/s
Required pump software for retrofitting V2.5 or higher
Ethernet protocol PROFINET IO / Modbus TCP(selected via rotary switch)
Application layer DHCP, HTTP, Ping, FTP, SMTP, SNTP, Modbus TCPTransport layer TCPInternet layer Internet protocol V4 (IPv4)Link layer ARP, media access control (Ethernet)
Recommended cable type Screened/unscreened, twisted-pair cables, CAT5, CAT5e or CAT6Maximum cable length 100 m at 10/100 Mbits/sSupported data rates 10 / 100 Mbits/s
-
Acc
esso
ries
for
smal
l dos
ing
pum
ps u
p to
60
l/h
7
Accessories for dosing pumps 1
HosesHoses in various materials, sizes and lengths for small dosing pumps.
Fig. 7 Hoses
Technical data
* Viscosity similar to water
TM04
826
8 04
11
Max. flow rate*[l/h]
Size(internal/external diameter)
[mm]Material Max. pressure at 20 °C[bar]
Length[m] Product number
7.5 4/6
PE 133 91835676
10 9183650450 91835680
PVC 0.53 96701733
10 9670213350 96727418
ETFE 203 95730337
10 9573033850 95730339
17 5/8 PE 133 95730888
10 9672739350 95730889
30
6/9
PE 123 96727409
10 9672741250 96727415
PVC 0.53 95730334
10 9573033550 95730336
ETFE 203 95730340
10 9573034150 95730342
6/12 PVC, textile-reinforced 233 96693751
10 9665357150 91835686
60 9/12
PE 93 96727395
10 9670565750 96727398
PVC 0.53 96727434
10 9573089050 95724702
ETFE 133 95730343
10 9573034450 95730345
-
Accessories for sm
all dosing pumps up to 60 l/h
8
Accessories for dosing pumps1
Foot valves FVFoot valves are installed at the lower end of the inlet hose. They are available either without level indication or with low-level and empty-tank indication.Foot valves include:• Weight• Strainer (mesh size approx. 0.8 mm)• Non-return valve• Hose connection set: 4/6 mm, 6/9 mm, 6/12 mm and
9/12 mm• Pipe connection set: threaded, Rp 1/4", internal
thread (stainless steel).Foot valves with low-level and empty-tank indication include additionally:• Reed-switch unit with two floaters• 5 metres of cable with PE jacket• M 12 plug to connect DDA, DDC, DDE or DDI
dosing pump• PE cap, ∅58 mm, for assembly in Grundfos
cylindrical tanks, or for use with tank adapters.The contact type of the low-level and empty-tank indication is factory-set to NO. The contact type can be set to NC by turning the floaters upside down.Electrical data of the level indication:• Max. voltage: 48 V• Max. current: 0.5 A• Max. load: 10 VA
Fig. 8 Foot valves: without level indication (left), with level indication (right)
Dimensions
Fig. 9 Foot valves: stainless-steel (left), PE or PVDF (centre and right)
Technical data
TM04
847
6 05
12
TM04
846
1 03
12
Max. flow rate[l/h]
Material Product number
Body Gasket Ball Without level indication With level indication
60
PEFKM, EPDM Ceramic 98070951 98070966
PTFE Ceramic 98070952 98070967
PVDFFKM, EPDM Ceramic 98070953 98070968
PTFE Ceramic 98070954 98070969SS PTFE SS 98070963 -
-
Acc
esso
ries
for
smal
l dos
ing
pum
ps u
p to
60
l/h
9
Accessories for dosing pumps 1
Rigid suction lances RSLGrundfos offer a comprehensive range of rigid suction lances for a variety of chemical containers.Rigid suction lances are installed at the lower end of the inlet hose. They are available either without level indication or with low-level and empty-tank indication. Their immersion depth is adjustable.Rigid suction lances include:• Strainer (mesh size approx. 0.8 mm)• Non-return valve• Hose connection set: 4/6 mm, 6/9 mm, 6/12 mm and
9/12 mm• Adjustable tank connection with holes for e.g. relief
line.Rigid suction lances with low-level and empty-tank indication include additionally:• Reed-switch unit with 2 floaters• 5 metres of cable with PE jacket• M 12 plug to connect DDA, DDC, DDE or DDI
dosing pump.The contact type of the low-level and empty-tank indication is factory-set to NO. The contact type can be set to NC by turning the floaters upside down.Electrical data of the level indication:• Max. voltage: 48 V• Max. current: 0.5 A• Max. load: 10 VA
Fig. 10 Rigid suction lance
Dimensions
Fig. 11 Rigid suction lance
Dimensions / Selection
* Suitable adapters see page 11
TM04
845
8 03
12
TM04
846
0 03
12
For dosing tank type Tank volume[l]Recommended
immersion depth (L)[mm]
Grundfos cylindrical tank (see page 22)
40 40060 500
100 690200 690300 980500 1100
1000 1200Grundfos square tank (see page 21)* 100 690
L-ring drum*120 820220 980
Steel drum* 216 980
Standard jerricans according to EN 12712*
12, 33 (large cap) 40025, 30, 33 500
60 690IBC* all sizes 1200
-
Accessories for sm
all dosing pumps up to 60 l/h
10
Accessories for dosing pumps1
Technical data
* Minimum immersion depth for all sizes: approx. 140 mm
Max. flow rate[l/h]
Max. immersion depth*[mm]
Material Product number
Body Gasket Ball RSL without level indicationRSL with level
indication
60
400PE
FKM, EPDM Ceramic 98070978 98071074PTFE Ceramic 98070979 98071075
PVDFFKM, EPDM Ceramic 98070980 98071076
PTFE Ceramic 98070981 98071077
500PE
FKM, EPDM Ceramic 98070990 98071086PTFE Ceramic 98070991 98071087
PVDFFKM, EPDM Ceramic 98070992 98071088
PTFE Ceramic 98070993 98071089
570PE
FKM, EPDM Ceramic 98071002 98071098PTFE Ceramic 98071003 98071099
PVDFFKM, EPDM Ceramic 98071004 98071100
PTFE Ceramic 98071005 98071101
690PE
FKM, EPDM Ceramic 98071014 98071110PTFE Ceramic 98071015 98071111
PVDFFKM, EPDM Ceramic 98071016 98071112
PTFE Ceramic 98071017 98071113
820PE
FKM, EPDM Ceramic 98071026 98071122PTFE Ceramic 98071027 98071123
PVDFFKM, EPDM Ceramic 98071028 98071124
PTFE Ceramic 98071029 98071125
980PE
FKM, EPDM Ceramic 98071038 98071134PTFE Ceramic 98071039 98071135
PVDFFKM, EPDM Ceramic 98071040 98071136
PTFE Ceramic 98071041 98071137
1100PE
FKM, EPDM Ceramic 98071050 98071146PTFE Ceramic 98071051 98071147
PVDFFKM, EPDM Ceramic 98071052 98071148
PTFE Ceramic 98071053 98071149
1200PE
FKM, EPDM Ceramic 98071062 98071158PTFE Ceramic 98071063 98071159
PVDFFKM, EPDM Ceramic 98071064 98071160
PTFE Ceramic 98071065 98071161
-
Acc
esso
ries
for
smal
l dos
ing
pum
ps u
p to
60
l/h
11
Accessories for dosing pumps 1
Accessories for suction lances and foot valves with level indicationAdapters for containersThese adapters allow the installation of standard rigid suction lances (G 2" thread) and foot valves with level indication (PE cap) on different types of containers.
Fig. 12 Adapters for containers
Technical data
TM04
850
6 07
12
Adapter type For container type Remark Product number
TM04
847
0 05
12
Counter nut for tanks without threaded opening, e.g. 100-litre square tank or 1000-litre cylindrical tank PVC, grey 98071170
TM04
847
1 05
12 Containers with 2" NPT threaded opening PVC, grey 98156690
Drums with S 70 x 6 coarse thread (MAUSER 2") PE, blue 98071171
Drums with S 56 x 4 coarse thread (TriSure®) PE, orange 98071172
TM04
847
3 05
12
Jerricans with small opening (approx. ∅36), according to EN 12713 PE, green 98071173
Jerricans with medium-sized opening (approx. ∅45), according to EN 12713 PE, yellow 98071174
Jerricans with large opening (approx. ∅57), according to EN 12713 PE, brown 98071175
US containers with bung hole of 63 mm (ASTM International) PE, white 98071176
TM04
847
2 05
12
IBC (Intermediate Bulk Container) with opening of ∅150 mm, S 160 x 7 PE, black 98071177
-
Accessories for sm
all dosing pumps up to 60 l/h
12
Accessories for dosing pumps1
Emission protection kitsGas emitted by liquid in a container can cause bad odour and corrosion. Emission protection kits help avoid such problems. Rigid suction lances can be retrofitted with emission protection kits.Two variants are available:• Emission protection kit with snifting valve: no gas
can escape from the container, but air can be drawn in.
• Emission protection kit for use with filter: gas can escape from the container and air can be drawn in. The kit can be connected to a filter by means of a 4/6 mm hose.
Emission protection kits include:• Gasket for the tank adapter• Snifting valve or hose nipple 4/6mm (hose is not
included)• Gasket for the cable outlet.
Fig. 13 Emission protection kit
Order data
M 12-plug-to-flat-plug adapterThe adapter allows to connect rigid suction lances or foot valves with level indication to pumps with a level input designed for flat plugs (e.g. DMX and DMH with AR control unit).
Order data
TM06
837
2 03
17
Position Description
A Gasket for the cable outletB Air valveC Gasket for the tank adapter
Variant Product numberEmission protection kit with snifting valve 98071178Emission protection kit for use with filter 98071179
A
B
C
AAAAAAAAAAAAAAAAAAAAAAA
BBBBBBBBBBBBBBBBBBBBBBBBBB
CCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCC
Description Product numberM 12-plug-to-flat-plug adapter 96635010
-
Acc
esso
ries
for
smal
l dos
ing
pum
ps u
p to
60
l/h
13
Accessories for dosing pumps 1
Injection unitsInjection units connect the dosing line with the process line. They ensure a minimum counterpressure of 0.7 bar and avoid backflow of the dosing liquid.In general, they include:• Injection pipe. PP, PVC and PVDF versions can be
shortened.• Spring-loaded non-return valve with Tantal spring.• Hose connection set: 4/6 mm, 6/9 mm, 6/12 mm,
and 9/12 mm.• Pipe connection set: threaded, Rp 1/4", internal
thread (stainless steel).
Standard injection unitsDimensions
Fig. 14 Standard injection unit, PP, PVC, and PVDF version
Fig. 15 Standard injection unit, stainless-steel version
Technical data
Injection units with lip valveInjection units with lip valve are typically used to add sodium hypochlorite solution to water with a high carbonate content. The FKM lip prevents crystallisation and blocking caused by alkali carbonate reactions at the point of injection.
Dimensions
Fig. 16 Injection unit with lip valve
Technical data
TM04
828
0 04
11TM
04 8
281
0411
G 1
/2
L 2 L 1
G 1
/2
L 1L 2
Max. flow rate[l/h]
Max. pressure[bar]
Material DimensionsProduct number
Body Gasket Ball L 1 [mm]L 2
[mm]
60
16
PPFKM Ceramic 100 47 95730904
EPDM Ceramic 100 47 95730908
PVCFKM Ceramic 100 47 95730912
EPDM Ceramic 100 47 95730916PTFE Ceramic 100 47 95730920
PVDFFKM Ceramic 100 47 95730924
EPDM Ceramic 100 47 95730928PTFE Ceramic 100 47 95730932
100 Stainless steel PTFE Stainless steel 27 50 95730936
16 PVCFKM Ceramic 300 47 95730940
EPDM Ceramic 300 47 95730944PTFE Ceramic 300 47 95730948
TM04
828
2 04
11
G 1
/2
L 1L 2
Max. flow rate[l/h]
Max. pressure[bar]
Material DimensionsProduct number
Body Gasket Ball L 1[mm]L 2
[mm]60 16 PVC FKM Ceramic 55 59 95730964
-
Accessories for sm
all dosing pumps up to 60 l/h
14
Accessories for dosing pumps1
Injection units with ball valveInjection units with ball valve are used for applications where the injection point must be closable. The ball valve is placed between the injection pipe and the spring-loaded non-return valve. Thus, the dosing line can be completely disconnected from the process. The non-return valve can be disassembled and cleaned without stopping the process and emptying the process line.
Dimensions
Fig. 17 Injection unit with ball valve
Technical data
Injection units with removable injection pipeInjection units with removable injection pipe are used where regular cleaning of the injection pipe is required. The injection pipe can be removed from the process line without stopping the process water flow. The injection point can be closed with the integrated ball valve. The immersion depth of the injection pipe can be adjusted.
Dimensions
Fig. 18 Injection unit with removable injection pipe
Technical data
Hot-injection units with ball valveHot-injection units with ball valve can be used for direct injection of the dosing medium into processes with a high process water temperature of up to 120 °C. Hot-injection units have a stainless-steel injection pipe and a bendable stainless-steel cooling pipe of 1 metre. The stainless-steel ball valve is installed between the injection pipe and the cooling pipe. The cooling pipe separates the hot parts from the non-return valve and the dosing line.
Dimensions
Fig. 19 Hot-injection unit with ball valve
Technical data
TM04
828
4 04
11
L 1L 2
G 1
/2
Max. flow rate[l/h]
Max. pressure[bar]
Material DimensionsProduct number
Body Gasket Ball L 1[mm]L 2
[mm]
6016 PVC
FKM Ceramic 100 183 95730952EPDM Ceramic 100 183 95730956
64 Stainless steel PTFE Stainless steel 27 138 95730960
TM04
828
5 04
11
L 1
G 1
/2
L 2
Max. flow rate[l/h]
Max. pressure[bar]
Material DimensionsProduct number
Body Gasket Ball L 1[mm]L 2
[mm]
60 10 PVCFKM Ceramic 185 280 95730968
EPDM Ceramic 185 280 95730972
TM04
828
6 04
11
L 1L 2
G 1
/2
Max. flow rate[l/h]
Max. pressure[bar]
Material DimensionsProduct number
Body Gasket Ball L 1[mm]L 2
[mm]
6016 PVDF PTFE Ceramic 27 1158 9573097664 Stainless steel PTFE Stainless steel 27 1158 95730980
-
Acc
esso
ries
for
smal
l dos
ing
pum
ps u
p to
60
l/h
15
Accessories for dosing pumps 1
Multi-function valves, pressure relief valves, pressure loading valvesMulti-function valves combine the functions of pressure relief valves and pressure loading valves. In addition, they allow deaeration of the pump and emptying of the outlet line for maintenance.Pressure relief valves protect the pump and the outlet-side installations against excessive pressure. All pressurised dosing installations should include a pressure relief valve.Pressure loading valves maintain a certain counterpressure for the dosing pump. They are used in the following applications:• too low counterpressure or no counterpressure at all• fluctuating system pressure with outlet-side
pulsation damper.• To prevent syphoning, when the inlet pressure is
higher than the counterpressure.
Fig. 20 Multi-function valve, pressure relief valve, pressure loading valve
Multi-function valvesA multi-function valve is mounted directly on the pump outlet side. The top connection is for the outlet line, the side connection leads the relief liquid back into the tank.• Loading pressure, adjustable from 1 to 4 bar, is
factory-set to 3 bar.• Relief pressure, adjustable from 7 to 16 bar, is
factory-set to 10 bar or 16 bar.• Maximum operating pressure: 16 bar.• Hose connection set: 4/6 mm, 6/9 mm, 6/12 mm,
and 9/12 mm.
Dimensions
Fig. 21 Multi-function valve
Technical data
TM04
828
7 04
11
TM04
828
8 04
11
92
139
45
4745
G 5/8
Ø 60
Max. flow rate[l/h]
Material Product number
Body Connections Gasket Diaphragm Relief pressure 10 barRelief pressure
16 bar
60 PVDF
PPFKM PTFE 95704585 95730821
EPDM PTFE 95704591 95730822
PVCFKM PTFE 95730807 95730823
EPDM PTFE 95730808 95730824PTFE PTFE 95730809 95730825
PVDFFKM PTFE 95730810 95730826
EPDM PTFE 95730811 95730827PTFE PTFE 95730812 95730828
-
Accessories for sm
all dosing pumps up to 60 l/h
16
Accessories for dosing pumps1
Pressure relief valves PRVPressure relief valves are installed in the outlet line near the pump using the 2 in-line connections. The side connection leads the relief liquid back into the tank.• Relief pressure, adjustable from 5 to 10 bar, is
factory-set to 10 bar, or• Relief pressure, adjustable from 7 to 16 bar, is
factory-set to 16 bar.• Maximum operating pressure: 16 bar.• Hose connection set: 4/6 mm, 6/9 mm, 6/12 mm,
and 9/12 mm.• Pipe connection set: threaded, Rp 1/4", internal
thread (stainless steel).
Dimensions
Fig. 22 Pressure relief valve. Dimensions in brackets apply to stainless-steel version.
Technical data
Pressure loading valves PLVPressure loading valves are installed in the outlet line after the pressure relief valve, and after the pulsation damper, if fitted.• Loading pressure, adjustable from 1 to 5 bar, is
factory-set to 3 bar.• Maximum operating pressure: 16 bar.• Hose connection set: 4/6 mm, 6/9 mm, 6/12 mm,
and 9/12 mm.• Pipe connection set: threaded, Rp 1/4", internal
thread (stainless steel).
Dimensions
Fig. 23 Pressure loading valve. Dimensions in brackets apply to stainless-steel version.
Technical dataTM
04 8
290
0411
Ø4.5(-)
48(20)
96(4
0)
78 (-)
21(22)
82(82)
68(6
8)
Max. flow rate[l/h]
Material Product number
Diaphragm Body and connections Gasket Relief pressure 10 barRelief pressure
16 bar
60 PTFE
PP FKM / EPDM 95730757 95730773
PVCFKM / EPDM 95730758 95730774
PTFE 95730759 95730775
PVDFFKM / EPDM 95730760 95730776
PTFE 95730761 95730777Stainless steel No gaskets 95730771 95730783
TM04
829
2 04
11
21 (22)
68 (6
8)
82 (82)
Ø4.5 (-)
78 (-)
96 (4
0)
Max. flow rate[l/h]
MaterialProduct number
Diaphragm Body and connections Gasket
60 PTFE
PP FKM / EPDM 95730741
PVCFKM / EPDM 95730742
PTFE 95730743
PVDFFKM / EPDM 95730744
PTFE 95730745Stainless steel No gaskets 95730751
-
Acc
esso
ries
for
smal
l dos
ing
pum
ps u
p to
60
l/h
17
Accessories for dosing pumps 1
Pressure valvesPressure valves provide a constant counterpressure of 3 bar. They are particularly required for DDA-FC or DDA-FCM pumps at very small flow rates.Pressure valves are installed either directly on the pump outlet side, or on the pressure relief valve.• Loading pressure: 3 bar, not adjustable.• Maximum system pressure: 16 bar.• Spring material: Alloy C-4 (NiMo16CrTi, material
number 2.4610).• No connections included.
Dimensions
Fig. 24 Pressure valve
Technical data
TM04
829
3 04
11
87
G 5/8
Max. flow rate[l/h]
MaterialProduct number
Ball Body Gaskets
60Ceramic
PPFKM 95730325
EPDM 95730326
PVCFKM 95730327
EPDM 95730328PTFE 95730329
PVDFFKM 95730330
EPDM 95730331PTFE 95730332
Stainless steel Stainless steel PTFE 95730333
-
Accessories for sm
all dosing pumps up to 60 l/h
18
Accessories for dosing pumps1
Pump connection kits and inlay kitsRetrofit pump connection kits and inlay kits for the integration of Grundfos standard dosing pumps into installations with various sizes of hoses or pipes.A pump connection kit includes:• 1 set of inlays• 1 union nut.The inlay kits are used to connect pumps and accessories to pipes or hoses that differ from Grundfos standard sizes.An inlay kit includes:• 2 sets of inlays.
Fig. 25 Left: pump connection kit; right: inlay kit
Technical data
TM04
829
4 04
11
TM04
829
5 04
11
Connection type Size MaterialProduct number
Connection kit Inlay kit
Hose (cone and ring)
4/6 mm, 6/9 mm, 6/12 mm, 9/12 mmPP 97691902 -
PVC 97691903 -PVDF 97691904 -
0.17" x 1/4", 1/4" x 3/8", 3/8" x 1/2"PP 97691905 -
PVC 97691906 -PVDF 97691907 -
Hose (cone and ring)
4/6 mm, or 0.17" x 1/4"PP 97702474 95730984
PVC 97702485 95730720PVDF 97702495 95730729
4/9 mmPP 98153922 98153977
PVC 98153944 98154006PVDF 98153949 98154029
5/8 mmPP 97702475 95730711
PVC 97702486 95730721PVDF 97702496 95730730
6/8 mmPP 97702476 95730712
PVC 97702487 95730722PVDF 97702497 95730731
6/9 mmPP 97702477 95730713
PVC 97702488 95730723PVDF 97702498 95730732
6/12 mmPP 97702478 95730714
PVC 97702489 95730724PVDF 97702499 95730733
9/12 mmPP 97702479 95730715
PVC 97702490 95730725PVDF 97702500 95730734
1/4" x 3/8PP 97702482 95730718
PVC 97702492 95730727PVDF 97702503 95730737
3/8" x 1/2"PP 97702483 95730719
PVC 97702493 95730728PVDF 97702504 95730738
Hose (cutting ring type) 1/8" x 1/4"PP 97702481 95730717
PVDF 97702502 95730736
Pipe welding External diameter 16 mmPP 97702480 95730716
PVDF 97702501 95730735Pipe cementing Internal diameter 12 mm PVC 97702491 95730726
Pipe, external thread 1/2" NPT
PP 97702484 -PVC 97702494 -
PVDF 97702505 -Stainless steel 97702508 -
Pipe, internal threadRp 1/4" Stainless steel 97702472 95730739
1/4" NPT Stainless steel 97702473 95730740
Pipe (cutting ring type)4/6 mm Stainless steel 97702506 -
8/10 mm Stainless steel 97702507 -
-
Acc
esso
ries
for
smal
l dos
ing
pum
ps u
p to
60
l/h
19
Accessories for dosing pumps 1
Adapters
Threaded adaptersThreaded adapters are used to convert between different threaded connection sizes.
A threaded adapter kit includes:• 1 adapter• 1 O-ring.
Technical data
Union nut adaptersUnion nut adapters consist of a rigid pipe with union nuts on both ends. They have neither gaskets nor glued or welded connections.
Technical data
TypeThreaded connection size Material
Product numberInternal thread External thread Body Gaskets
TM04
829
6 04
11
G 3/8" G 5/8"
PP FKM / EPDM 95730407
PVCFKM / EPDM 95730408
PTFE 95730409
PVDFFKM / EPDM 95730410
PTFE 95730411
TM04
829
7 04
11
G 5/8" G 3/8"
PP FKM / EPDM 95730412
PVCFKM / EPDM 95730413
PTFE 95730414
PVDFFKM / EPDM 95730415
PTFE 95730416
TM04
829
8 04
11
G 5/8" G 3/4"
PP FKM / EPDM 95730417
PVCFKM / EPDM 95730418
PTFE 95730419
PVDFFKM / EPDM 95730420
PTFE 95730421
TM04
829
9 04
11
G 5/8" G 1 1/4"
PP FKM / EPDM 95730422
PVCFKM / EPDM 95730423
PTFE 95730424
PVDFFKM / EPDM 95730425
PTFE 95730426
TM04
830
0 04
11
G 5/8" M 20 x 1.5
PP FKM / EPDM 95730427
PVCFKM / EPDM 95730428
PTFE 95730429
PVDFFKM / EPDM 95730430
PTFE 95730431
TM04
847
5 06
12
G 5/8" M 30 x 3.5 PVDF
FKM / EPDM 98154048
PTFE 98154054
TM04
830
1 04
11
G 1 1/4" G 5/8"
PP FKM / EPDM 95730432
PVCFKM / EPDM 95730433
PTFE 95730434
PVDFFKM / EPDM 95730435
PTFE 95730436
TypeThreaded connection size Material
Product numberInternal thread Internal thread Body
TM04
830
6 04
11
G 5/8" G 5/8"
PVC 95730437
PP 95730438
PVDF 95730439
-
Accessories for sm
all dosing pumps up to 60 l/h
20
Accessories for dosing pumps1
Hose-to-hose and hose-to-pipe adaptersTechnical data
T-piecesTechnical data
Type DescriptionConnections Material
Product numberSide 1 Side 2 Body and connections Gaskets
TM04
830
2 04
11
Valve body with two external threads G 5/8"
For hoses 4/6 mm, 6/9 mm, 6/12 mm, 9/12 mm
PP FKM / EPDM 95730367
PVCFKM / EPDM 95730368
PTFE 95730369
PVDFFKM / EPDM 95730370
PTFE 95730371
Without
PP FKM / EPDM 95730356
PVCFKM / EPDM 95730357
PTFE 95730358
PVDFFKM / EPDM 95730359
PTFE 95730360Without Threaded Rp 1/4 Stainless steel PTFE 95730361
TM04
836
0 07
11
Pipe cementing end on one side, external thread G 5/8" on the other side
For hoses 4/6 mm, 6/9 mm, 6/12 mm,
9/12 mmInternal ∅12 mm PVC
FKM / EPDM 95730378
PTFE 95730379
Without Internal ∅12 mm PVCFKM / EPDM 95730365
PTFE 95730366
TM04
830
3 04
11 Pipe welding end on one side, external thread G 5/8" on the other side
For hoses 4/6 mm, 6/9 mm, 6/12 mm,
9/12 mmExternal ∅16 mm
PP FKM / EPDM 95730377
PVDFFKM / EPDM 95730380
PTFE 95730381
Without External ∅16 mmPP FKM / EPDM 95730362
PVDFFKM / EPDM 95730363
PTFE 95730364
Type DescriptionConnections Material
Product numberBottom Top Side Body and connections Gaskets
TM04
830
4 04
11
Three external threads G 5/8"
For hoses 4/6 mm, 6/9 mm, 6/12 mm, 9/12 mm
PP FKM / EPDM 95730387
PVCFKM / EPDM 95730388
PTFE 95730389
PVDFFKM / EPDM 95730390
PTFE 95730391
- Without -
PP FKM / EPDM 95730346
PVCFKM / EPDM 95730347
PTFE 95730348
PVDFFKM / EPDM 95730349
PTFE 95730350
TM04
830
5 04
11
Two male threads G 5/8", one internal
connection with union nut
Union nut G 5/8" Without
For hoses 4/6 mm, 6/9 mm,
6/12 mm, 9/12 mm
PP FKM / EPDM 95730397
PVCFKM / EPDM 95730398
PTFE 95730399
PVDFFKM / EPDM 95730400
PTFE 95730401
Without
PP FKM / EPDM 95730351
PVCFKM / EPDM 95730352
PTFE 95730353
PVDFFKM / EPDM 95730354
PTFE 95730355
-
Acc
esso
ries
for
smal
l dos
ing
pum
ps u
p to
60
l/h
21
Accessories for dosing pumps 1
Dosing tanks
Square tank, 100 litresThe closed, square tank has a screw cap and a mounting platform for one pump or two pumps in parallel.The pump mounting platform is higher than the screw cap to protect pumps and connections when filling chemicals into the tank.• Tank material: MDPE• Weight: 15 kg• Wall thickness: 4 mm• Liquid temperature: -20 °C to +45 °C.SMART Digital pumps can be fitted directly on the mounting platform by means of brass inserts moulded into the platform. For other pumps a bracket is required.The square tank is prepared for a G 3/4" drain valve.When using a rigid suction lance in the tank, choose the counter nut for fixing (see page 11).
Fig. 26 Square tank
Dimensions
Fig. 27 Square tank, dimensions
Order data
TM04
830
7 04
11
TM04
830
8 04
11
Tank volume[l] Product number
100 96489271
Ø152
540
670
50050
0
98
98
98
137
192
M5
-
Accessories for sm
all dosing pumps up to 60 l/h
22
Accessories for dosing pumps1
Cylindrical tanksCylindrical tanks are available transparent or black. They have a litre scale and a black screw cap.• Tank material: LLDPE, UV-stabilised• Liquid temperature: -20 °C to +45 °C.All cylindrical tanks are prepared for a G 3/4" opening for a drain valve, and have a screw plug (PE/EPDM).The cylindrical tanks with volumes of 60, 100, 200, 300 and 500 litres include additionally:• Threaded M 6 inserts for the assembly of a SMART
Digital, a DDI, or a DMX model 221 dosing pump. For other pumps a bracket is required.
• A G 2" opening for a rigid suction lance or a foot valve, closed with a screw plug
• A flange for an electric stirrer with threaded inserts• Threaded M 6 inserts at the bottom part for floor
mounting with a set of floor-mounting brackets (see page 24).
Fig. 28 Cylindrical tank, 60 litres
Technical data
Dimensions
Fig. 29 Cylindrical tank, 40 litres
TM04
846
8 04
12
Tank volume[l] Prepared for direct assembly of an electric stirrer
Weight[kg]
Product number
Transparent Black40 - 3.4 96688081 95701166
60- 5.5 98148805 98149053
Yes 5.5 98150038 98150040
100- 7.5 98149057 98149082
Yes 7.5 98150051 98150052
200- 11.5 98149215 98149224
Yes 11.5 98150053 98150054
300- 13 98149245 98149252
Yes 13 98150055 98150056
500- 28 98149266 98149269
Yes 28 98150057 98150058
1000- 40 96688086 95706305
Yes, with reinforced beam 48 98173675 98173752
TM04
831
0 04
11
Ø16
0
Ø420
Ø160
Rp 3/4"
350
420
45
-
Acc
esso
ries
for
smal
l dos
ing
pum
ps u
p to
60
l/h
23
Accessories for dosing pumps 1
Fig. 30 Cylindrical tank, 60 and 100 litres
Fig. 31 Cylindrical tank, 200 and 300 litres
Fig. 32 Cylindrical tank, 500 litres
Fig. 33 Cylindrical tank, 1000 litres
TM04
846
5 04
12TM
04 8
466
0412
TM04
846
7 04
12TM
04 8
315
0411
Rp 3/4"
Ø1080
1260
Ø160
1150
50
-
Accessories for sm
all dosing pumps up to 60 l/h
24
Accessories for dosing pumps1
Collecting trayThe collecting tray is available in several sizes to suit the respective dosing tank size. It collects chemicals that might leak out of the tank, and protects the environment.• Material: PE• Colour: transparent.
Fig. 34 Collecting tray
Accessories for dosing tanks
Fig. 35 Dissolving hopper, dimensions Fig. 36 Handheld mixer
Technical data
TM04
831
6 04
11
For tank size[l]
Volume [l]
Dimensions (diameter x height)[mm] Product number
60 80 500 x 545 96726831100 120 500 x 700 96726832200 210 770 x 595 98150059300 400 770 x 960 96726834500 500 860 x 980 95701272
1000 1000 1150 x 1080 96726836
TM04
831
8 04
11
Ø 270
Ø 140
Ø 70
283
120
TM04
847
7 05
12
Description Specifications Material Product numberDrain valve for installation in the threaded sleeve of the dosing tank Dosing tank connection G 3/4" PVC 96689132
Ventilation valve Spring-loaded, opening pressure 0.05 bar PVC / FKM / glass 96694401
Dissolving hopper for washing powders into the dosing tank
Dosing tank connection: DN 40 through-bolt; water connection: G 5/4", with union nut and inlay for PVC pipe (cementing diameter 25 mm)
PVC 96726979
Handheld mixer for use in dosing tanksShaft length 1200 mm, length can be adapted to the corresponding dosing tank, with DN 15 through-bolt for connection at the dosing tank
PE 98133793
Set of floor-mounting brackets 4 floor-mounting brackets with fixing screws 98149921Set of screws for mounting a pump on a 100-litre square tank For pump types DDA, DDC, DDE Stainless steel 95730862
Set of screws for mounting a pump on a 60-, 100-, 200-, 300-, or a 500-litre cylindrical tank For pump types DDA, DDC, DDE, DDI, DMX model 221 Stainless steel 98159495
Set of screws for mounting a pump on a 40-litre or a 1000-litre cylindrical tank For pump types DDA, DDC, DDE, DDI, DMX model 221 PP 95730864
-
Acc
esso
ries
for
smal
l dos
ing
pum
ps u
p to
60
l/h
25
Accessories for dosing pumps 1
Water meterThe in-line water meter with potential-free pulse signal is suitable for use in flow-proportional dosing applications.• Qn 1.5 and Qn 2.5 meters are of the multi-jet, dry
dial type, for cold water up to 30 °C, or hot water up to 90 °C.
• Qn 15 meters and up are of the helical vane type, for cold water up to 50 °C, or hot water up to 120 °C.
• Max. pressure: 16 bar.If the water meter is connected directly to the pump pulse input, use a control plug (PN 96698715).• Qn 1.5 to Qn 15 meters are threaded.• Qn 40 to Qn 150 meters are flanged.• Cable length: 3 m.
Fig. 37 Water meter
* Maximum load, Reed contact: 30 VAC/VDC, 0.2 A.** Maximum load, Namur contact: 8-12 VDC, 1 kOhm (requires external power supply).
Dimensions
TM04
831
7 04
11
Qn[m3/h]
Pulse rate[l/pulse]
Maximum short-period
capacity[m3/h]
Maximum pressure
[bar]
Transitional capacity with
error ± 2 %[l/h]
Minimum capacity with
error ± 5 %[l/h]
Product number
Maximum water temperature
30 °C 50 °C 90 °C 120 °C1.5* 1 3 16 120 50 96446846 - 96446897 -2.5* 2.5 5 16 200 70 96446847 - 96446898 -15* 10 30 16 3000 450 - 96446848 - 964468991.5* 0.25 3 16 120 50 96482640 - 96482643 -2.5* 0.25 5 16 200 70 96482641 - 96482644 -15* 2.5 30 16 3000 450 96482642 - 96482645 -40** 100 80 10 4000 700 - 96446849 - 9644690060** 25 120 10 6000 1200 - 96446850 - 96446901
150** 100 300 10 12000 3000 - 96446851 - 96446902
Size Connections Installation kit connection Port-to-port length[mm]Port-to-port length incl. kit
[mm]
Threaded connectionQn 1.5 G 3/4" G 1/2" 165 245Qn 2.5 G 1" G 3/4" 190 288Qn 15 G 2.5 G 2" 300 438
Flanged connectionQn 40 DN 80 225 -Qn 60 DN 100 250 -
Qn 150 DN 150 300 -
-
Accessories for m
edium-sized dosing pum
ps up to 460 l/h
26
Accessories for dosing pumps2
2. Accessories for medium-sized dosing pumps up to 460 l/h
Accessories overviewGrundfos offer a comprehensive range of accessories covering every need when dosing with Grundfos pumps.
Fig. 38 Dosing pump with accessories
TM06
837
4 03
17
Foot valves and rigid suction lances, see page 29 and page 30
Electric stirrers, see page 48
Pump connection kits and inlay kits, see page 47
Hoses, see page 28
Injection units, see page 34
Pressure relief valves, pressure loading valves, see page 35
Pulsation dampers,see page 38
Vacuum pump kits, see page 41
Threaded adapters, see page 50
Cables and plugs, see page 27
Wall brackets, see page 51
Pressure valves,see page 37
Withdrawal devices, see page 49
-
Acc
esso
ries
for
med
ium
-siz
ed d
osin
g pu
mps
up
to 4
60 l/
h
27
Accessories for dosing pumps 2
Cables and plugsThe listed cables and plugs are suitable for the connection of a pump to external control devices, such as process controllers, flow meters, start/stop contacts and level sensors.
Fig. 39 Cable and plug for DDA, DDE, DMX, DMH and DDI pumps
Technical data• Cable material: PVC, 0.34 mm2
• Plug size: M 12
TM01
895
5 09
00
Socket for DDA and DDE
Socket for DMX, DMH and DDI Application Pins Plug type
Cable length[m]
Product number
Input Analog pulse External stop 4Straight
2 966090145 96609016
No cable 96698715Angled 2 96693246
Output Relay 1Relay 2 4Straight
2 966090175 96609019
No cable 96696198Angled 2 96698716
Output Analog 5Straight
2 966329215 96632922
No cable 96609031Angled 2 96699697
DDI Low-levelEmpty tank 4 Straight - 96698715
- DMX/DMH AR
Input Low-levelEmpty tank 3Straight with
soldered cable - 96630345
Adapter, flat-round Low-levelEmpty tank 4 - 96635010
- DDI
Profibus Y-connector - 96693735
Profibus Terminating resistor - 96693737
Input/Output GENIbus 5 Straight 3 98589048
- Mains connection for DDI/DDA/DDE 110-240 VAC 3 Angled - 96698717
4
3
2
5
5
6
-
Accessories for m
edium-sized dosing pum
ps up to 460 l/h
28
Accessories for dosing pumps2
HosesHoses in various materials, sizes and lengths for medium-sized dosing pumps.
Fig. 40 Hoses
Technical data
TM01
895
8 09
00
Max. flow rate[l/h]
Sizeinternal/external diameter
[mm]Material
Max. pressureat 20 °C
[bar]Length
[m]Product number
200 13/20 PVC,textile reinforced 153 96727423
10 9672742050 96692592
46019/27 PVC,textile reinforced 12
3 9672742610 9669620050 96695788
19/24.6 PVC,reinforced with a plastic spiral 7 3 99168771
-
Acc
esso
ries
for
med
ium
-siz
ed d
osin
g pu
mps
up
to 4
60 l/
h
29
Accessories for dosing pumps 2
Foot valves FVFoot valves are installed at the lower end of the inlet hose. They have no level indication.Foot valves include:• Strainer (mesh size approx. 0.8 mm)• Non-return valve• Hose and pipe connection set:
– for hoses with internal diameter 19 or 20 mm– for pipes with external diameter 25 mm (PE
includes PVC inlay, PVDF includes PVDF inlay)• Pipe connection set: threaded, Rp 3/4", internal
thread (stainless steel).Remark: When using the foot valves with hose installation, a rigid pipe should be slipped over the hose to keep the suction line straight and upright in the tank.
Fig. 41 Foot valve
Dimensions
Fig. 42 Foot valves: stainless steel (left), PE/PVDF (right)
Technical data
* Stainless steel 1.4571, 1.4435, 1.4305** Stainless steel 1.4401
TM06
842
7 05
17
TM06
807
5 45
16
Material L [mm]d
[mm]PE/PVDF 57 53
SS 57 50
Max. flow rate[l/h]
Material Product numberBody Gasket Ball
460
PEFKM/EPDM Ceramic 99168633
PTFE Ceramic 99168635
PVDFFKM/EPDM Ceramic 99168636
PTFE Ceramic 99168649SS* PTFE SS** 99170593
d
L
d
L
-
Accessories for m
edium-sized dosing pum
ps up to 460 l/h
30
Accessories for dosing pumps2
Rigid suction lances RSLGrundfos offer a comprehensive range of rigid suction lances for a variety of chemical containers.Rigid suction lances are installed at the lower end of the inlet hose. They are available either without level indication or with low-level and empty-tank indication. Their immersion depth is adjustable.Rigid suction lances include:• Strainer (mesh size approx. 2.2 mm)• Non-return valve• Hose and pipe connection set:
– for hoses with internal diameter 19 or 20 mm– for PVC pipes with external diameter 25 mm
• Adjustable tank connection with holes for a deaeration line.
Rigid suction lances with low-level and empty-tank indication include additionally:• Reed switch unit with 2 floaters• 5 metres of cable with PE jacket• M 12 plug to connect DDA, DDE, DME or DDI
dosing pumps.The contact type of the low-level and empty-tank indication is factory-set to NO. The contact type can be set to NC by turning the floaters upside down.Electrical data of the level indication:• Max. voltage: 48 V• Max. current: 0.5 A• Max. load: 10 VA
Fig. 43 Rigid suction lance
Dimensions
Fig. 44 Rigid suction lance
* Switching level for water
Dimensions / Selection
* Suitable adapters see Accessories for rigid suction lances RSL, page 31
Technical data
TM06
842
3 05
17
TM06
813
0 06
17
A[mm]
B[mm]
C[mm]
D[inch]
E[inch]
∅F[mm]
G*[mm]
H*[mm]
I[mm]
500690980
1200
159 140 G 5/4 G 2 40 138 34 8.7
For dosing tank type Tank volume [l]Recommended
immersion depth (A)[mm]
Grundfos cylindrical tank
60 500100 690200 690300 980500 1200
1000 1200Grundfos square tank 100 690
L-ring drum*120 980220 980
Steel drum* 216 980
Standard jerricans according to EN 12712*
33 (large cap) 50025, 30, 33 500
60 690IBC* All sizes 1200
D
B
C
A
EØF
GH
I
Max. flow rate[l/h]
Max. immersion depth (A)
[mm]
Material in contact with liquid Product number
Body Gasket Ball RSL without level indicationRSL with level
indication
460
500 PEFKM/EPDM Ceramic 99199363 99161410
PTFE Ceramic 99199364 99161411
690 PEFKM/EPDM Ceramic 99199365 99161412
PTFE Ceramic 99199366 99161943
980 PEFKM/EPDM Ceramic 99199367 99161944
PTFE Ceramic 99199368 99161945
1200 PEFKM/EPDM Ceramic 99199369 99161946
PTFE Ceramic 99199370 99161947
-
Acc
esso
ries
for
med
ium
-siz
ed d
osin
g pu
mps
up
to 4
60 l/
h
31
Accessories for dosing pumps 2
Accessories for rigid suction lances RSLAdapters for containersThese adapters allow the installation of standard rigid suction lances (G 2" thread) on different types of containers.
Fig. 45 Adapters for containers
Technical data
TM04
850
6 07
12
Adapter type For container type Remark Product number
TM04
847
0 05
12
Counter nut for tanks without threaded opening, e.g. 100-litre square tank or 1000-litre cylindrical tank PVC, grey 98071170
TM04
847
1 05
12 Containers with 2" NPT threaded opening PVC, grey 98156690
Drums with S 70 x 6 coarse thread (MAUSER 2") PE, blue 98071171
Drums with S 56 x 4 coarse thread (TriSure®) PE, orange 98071172
TM04
847
3 05
12 Jerricans with medium-sized opening (approx. ∅45 mm), according to EN 12713 PE, yellow 98071174
Jerricans with large opening (approx. ∅57 mm), according to EN 12713 PE, brown 98071175
US containers with bung hole of 63 mm (ASTM International) PE, white 98071176
TM04
847
2 05
12
IBC (Intermediate Bulk Container) with opening of ∅150 mm, S 160 x 7 PE, black 98071177
-
Accessories for m
edium-sized dosing pum
ps up to 460 l/h
32
Accessories for dosing pumps2
Emission protection kitsGas emitted by liquid in a container can cause bad odour and corrosion. Emission protection kits help avoid such problems. Rigid suction lances can be retrofitted with emission protection kits.Two variants are available:• Emission protection kit with snifting valve: no gas
can escape from the container, but air can be drawn in.
• Emission protection kit for use with filter: gas can escape from the container and air can be drawn in. The kit can be connected to a filter by means of a 4/6 mm hose.
Emission protection kits include:• Gasket for the tank adapter• Snifting valve or hose nipple 4/6 mm (hose is not
included)• Gasket for the cable outlet.
Fig. 46 Emission protection kit
Order data
M 12-plug-to-flat-plug adapterThe adapter allows to connect rigid suction lances or foot valves with level indication to pumps with a level input designed for flat plugs (e.g. DMX and DMH with AR control unit).
Order data
TM06
837
2 03
17
Position Description
A Gasket for the cable outletB Air valveC Gasket for the tank adapter
Variant Product numberEmission protection kit with snifting valve 98071178Emission protection kit for use with filter 98071179
A
B
C
AAAAAAAAAAAAAAAAAAAAAAA
BBBBBBBBBBBBBBBBBBBBBBBBBB
CCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCC
Description Product numberM12-plug-to-flat-plug adapter 96635010
-
Acc
esso
ries
for
med
ium
-siz
ed d
osin
g pu
mps
up
to 4
60 l/
h
33
Accessories for dosing pumps 2
Level-control unitsGrundfos level-control units are suitable for dosing pumps with input for level control.The contact type of the reed switch unit is factory-set to NO. The contact type can be set to NC by turning the floater(s).
Electrical data• Max. voltage: 48 V• Max. current: 0.5 A• Max. load: 10 VA
Level-control unit for electric stirrer protectionLevel-control units for electric stirrer protection are used for rigid suction lances for pumps up to 60 or 460 l/h. They are clipped to the rigid suction lances at the required switch-off height above the stirrer propeller.Level-control units can also be used for overfill protection or as an additional tank level indication.A level-control unit for electric stirrer protection includes:• Reed switch unit with 1 floater• 5 m cable with PE jacket and open wire ends• Clip for diameter 40 mm or 32 mm• Cable gland for mounting at the tank top
Dimensions
Fig. 47 Level-control unit for electric stirrer protection
Technical data
Flexible level-control unitThe flexible level-control unit is suitable for dosing pumps with level-control input and provides 2 level switches.A flexible level-control unit includes:• Reed switch unit with 2 floaters• 5 m of cable with PE jacket and M 12 plug• Weight that keeps the level-control unit in an upright
position at the tank bottom• PE cap, ∅58 mm, for assembly in Grundfos
cylindrical tanks, or for use with tank adapters
Dimensions
Fig. 48 Flexible level-control unit
Technical data
TM06
830
4 51
16
∅A[mm]
B[mm]
∅C[mm]
D[mm]
E[mm] F
40 47.5 32 20 182 M 12 x 1.532 43 32 28 190 M 12 x 1.5
F
E
ØA
B
ØC
D
Description Material ∅A[mm]Product number
Level-control unit for electric stirrer protection PE
32 9830621040 99174140
TM06
810
2 46
16
∅A[mm]
B[mm]
C[mm]
D[mm]
E[mm]
F[inch]
∅G[mm]
H[mm]
I[mm]
J[mm]
35 19 43.5 103.5 196 G 5/8 58 6 9 12
Description Material Product numberFlexible level-control unit PE 98375695
-
Accessories for m
edium-sized dosing pum
ps up to 460 l/h
34
Accessories for dosing pumps2
Injection unitsInjection units connect the dosing line with the process line. They ensure a minimum counterpressure of 0.7 bar and avoid backflow of the dosing medium. For all types and variants the maximum system pressure is 10 bar.In general they include:• Injection pipe with immersion depth of 120 mm. PP,
PVC and PVDF versions can be shortened.• Spring-loaded non-return valve with 2.4610 (Alloy
C-4) spring.• Hose and pipe connection set (PVC, PP, PVDF):
– for hose with internal diameter 19 or 20 mm– for pipe with external diameter 25 mm
• Pipe connection set (stainless steel): threaded, Rp 3/4", internal thread.
Standard injection units
Dimensions
Fig. 49 Injection unit
Technical data
* SS 1.4571 and SS 1.4408** SS 1.4401
Injection units with ball valveInjection units with ball valve are used for applications where the injection point must be closable. The ball valve is placed between the injection pipe and the spring-loaded non-return valve. Thus, the dosing line can be completely disconnected from the process. The non-return valve can be disassembled and cleaned without stopping the process and emptying the process line.
Dimensions
Fig. 50 Injection unit with ball valve, PVC version
Fig. 51 Injection unit with ball valve, stainless steel version
Technical data
* SS 1.4571 and SS 1.4408** SS 1.4401
TM06
842
8 05
17TM
06 8
076
4516
A[inch]
B[mm]
C[mm]
∅D[mm]
Wrench sizeE
[mm]
G 1 173 120 26.9PP, PVC,
PVDF 50
SS 46
Max. flow rate[l/h]
Material Product numberBody Gasket Ball
460
PVCFKM Ceramic 99168657
EPDM Ceramic 99168658PTFE Ceramic 99169217
PPFKM Ceramic 99169220
EPDM Ceramic 99169223
PVDFFKM Ceramic 99169227
EPDM Ceramic 99169228PTFE Ceramic 99169229
SS* PTFE SS** 99169230
B
C
ØD
A
E
TM06
842
9 05
17TM
06 8
370
0317
A[inch]
B[mm]
C[mm]
∅D[mm]
Wrench sizeE
[mm]G1 330 120 25 50
TM06
837
1 03
17
A[inch]
B[mm]
C[mm]
∅D[mm]
Wrench sizeE
[mm]G1 285.5 120 26.9 46
Max. flow rate[l/h]
Material Product numberBody Gasket Ball
460PVC
FKM Ceramic 99206582EPDM Ceramic 99206585
SS* PTFE SS** 99206586
BC
ØD A E
B
C
ØD A E
-
Acc
esso
ries
for
med
ium
-siz
ed d
osin
g pu
mps
up
to 4
60 l/
h
35
Accessories for dosing pumps 2
Pressure relief valves PRVPressure relief valves protect the pump and the outlet-side installations against excessive pressure. All pressurised dosing installations should include a pressure relief valve.Pressure relief valves are installed in the outlet line near the pump using the 2 in-line connections. The side connection leads the relief liquid back into the tank.• Relief pressure: factory-set to 10 bar, adjustable
from 3 to 10 bar• Maximum operating pressure 10 bar• Hose and pipe connection set (PVC, PP, PVDF):
– for hoses with internal diameter 19 or 20 mm– for pipes with external diameter 25 mm
• Pipe connection set (stainless steel): threaded, Rp 3/4", internal thread.
Fig. 52 Pressure relief valve
Dimensions
Fig. 53 Pressure relief valve (PP, PVC, PVDF version)
Fig. 54 Pressure relief valve, stainless steel version
Technical data
* SS 1.4571
TM06
842
1 05
17TM
06 8
077
4516
A[mm]
B[mm]
C[mm]
D[mm]
E[mm]
∅F[mm]
G[inch]
H[mm]
I[mm]
168 30 92 6.5 150 85 G 5/4 40 75
G
E
AB
C
IHD
ØF
TM06
824
7 49
16
A[mm]
B[mm]
C[mm] D
∅F[mm]
G[inch]
J[mm]
K[mm]
167 30 63 M 6 89 Rp 3/4" 10 17.5
Max. flow rate[l/h]
Material Product numberBody Gasket
460
PVCFKM/EPDM 99131032
PTFE 99141139PP FKM/EPDM 99141197
PVDFFKM/EPDM 99141212
PTFE 99141224
SS* - 99141228
AB
G
CØF
DK
G
J
-
Accessories for m
edium-sized dosing pum
ps up to 460 l/h
36
Accessories for dosing pumps2
Pressure loading valves PLVPressure loading valves maintain a constant counterpressure for the dosing pump.They are used in the following applications:• Too low counterpressure or no counterpressure at
all• Fluctuating system pressure with outlet-side
pulsation damper• To prevent syphoning, when the inlet pressure is
higher than the counterpressurePressure loading valves are installed in the outlet line after the pressure relief valve, and after the pulsation damper, if fitted.• Opening pressure: factory-set to approximately 3
bar, adjustable from 3 to 10 bar • Maximum operating pressure: 10 bar• Hose and pipe connection set (PVC, PP, PVDF):
– for hoses with internal diameter 19 or 20 mm– for pipes with external diameter 25 mm
• Pipe connection set (stainless steel): threaded, Rp 3/4", internal thread
Pressure loading valves must not be used as shut-off valves.
Fig. 55 Pressure loading valve
Dimensions
Fig. 56 Pressure loading valve (PP, PVC, PVDF version)
Fig. 57 Pressure loading valve, stainless steel version
Technical data
* SS 1.4571
TM06
842
2 05
17
TM06
809
0 45
16
A[mm]
B[mm]
C[mm]
D[mm]
E[mm]
∅F[mm]
G[inch]
H[mm]
168 30 92 6.5 150 85 G 5/4 40
TM06
824
6 49
16
A[mm]
B[mm]
C[mm] D
∅F[mm]
G[inch]
J[mm]
K[mm]
167 30 63 M 6 89 Rp 3/4" 10 17.5
Max. flow rate[l/h]
Material Product numberBody Gasket
460
PVCFKM/EPDM 99132186
PTFE 99140593PP FKM/EPDM 99140610
PVDFFKM/EPDM 99140646
PTFE 99140651
SS* - 99135772
E
B
A
G
C
H
D
ØF
AB
G
CØF
DK
J
-
Acc
esso
ries
for
med
ium
-siz
ed d
osin
g pu
mps
up
to 4
60 l/
h
37
Accessories for dosing pumps 2
Pressure valves PVPressure valves provide a constant counterpressure of 3 bar. They are particularly required for DDA-FCM pumps at very small flow rates.Pressure valves are installed either directly on the pump outlet side, or on the pressure relief valve.• Loading pressure: 3 bar, not adjustable• Maximum system pressure: 10 bar• Spring material: 2.4610 (Alloy C-4)• No connections included.
Dimensions
Fig. 58 Pressure valve
Technical data
TM06
840
4 04
17
Material A[mm]B
[inch]PVC
PVDF 94 G 5/4
SS 100 G 5/4
Max. flow rate [l/h]
Material Product numberBody Ball Gaskets
200PVC Ceramic
EPDM 99229021FKM 99229033
PVDF CeramicEPDM 99229018FKM 99229020
B
A
-
Accessories for m
edium-sized dosing pum
ps up to 460 l/h
38
Accessories for dosing pumps2
Pulsation dampers and calibration columnsPulsation dampers are used to even out the pulsating flow and pressure produced by positive displacement pumps like diaphragm dosing pumps. They can be installed before and after the pump.
Discharge-side pulsation dampers DB and DBGPulsation dampers DB and DBG are especially designed for installations with long outlet lines with a small diameter, or with rigid pipes. The pulsation dampers optimise the dosing accuracy and protect the pump and the outlet line against pressure surges.If the counterpressure in the system is low or fluctuating, the installation of a pressure loading valve PLV after the pulsation damper may be required to optimise its function.Pulsation dampers DB and DBG have an air or nitrogen cushion inside, which is separated from the dosing medium by a separating diaphragm. This keeps the charging pressure stable for a long time and avoids that air or nitrogen is dissolved in the dosing medium. For proper operation, the pressure in the air or nitrogen cushion must be set to approximately 80 % of the system pressure.In PVC, PP, and stainless steel pulsation dampers, an FKM or EPDM bladder is used as separating diaphragm, in PVDF pulsation dampers a PTFE bellows is used as separating diaphragm.Grundfos SMART Digital dosing pumps do not require a DB or DBG pulsation damper, if the flow rate is limited to 75 % of the maximum dosing capacity of the pump. In rigid pipe installations, the flow rate without pulsation damper should not exceed 50 % of the maximum dosing capacity of the pump.Pulsation dampers DBG include a pressure gauge for easy setting of the correct pressure. Pulsation dampers DB have no pressure gauge.
Suction-side pulsation dampers CSD with calibration scalePulsation dampers CSD help to ensure the accuracy of dosing pumps, which is highly dependent on proper suction conditions. In installations with long inlet lines or inlet lines with a small diameter, the use of a CSD pulsation damper is recommended.Pulsation dampers CSD have a transparent PVC cylinder with a fine volume scale. When combined with a shut-off valve in the inlet line, they can also be used for calibration or flow measurement. In installations without flooded suction, the optional manual vacuum pump kit simplifies the startup of the dosing pump.Pulsation dampers CSD can be used for multiple pumps that are supplied by the same inlet line.
Calibration columnsCalibration columns have a graduated glass cylinder with a fine scale. A shut-off valve on the lower end can disconnect them from the inlet-side installation during normal operation.One calibration column can be used for multiple pumps that are supplied by the same inlet line.Calibration columns must not be used as pulsation dampers.
Fig. 59 Pulsation dampers CSD, DBG and DB
TM06
844
9 06
17
-
Acc
esso
ries
for
med
ium
-siz
ed d
osin
g pu
mps
up
to 4
60 l/
h
39
Accessories for dosing pumps 2
Sizing guide for pulsation dampers DB, DBG, CSD and calibration columnsLook up your pump type in the table. Find the required pulsation damper or calibration column volume in the respective table column.
* For very low remaining pulsation, a larger damper than mentioned in the sizing guide should be used.
** A smaller damper than mentioned in the sizing guide is sufficient, if a high remaining pulsation is acceptable.
Pump typesPump stroke volume
[ml]
Required damper volume
Required calibration
column volume
[l]DB/DBG
[l]CSD
[l]
DDC-DDE 6-10 0.81
0.15
0.25 0.25
DDA 7.5-16* 0.74DDC 9-7 0.84
DDA 12-10 1.45DDC-DDE 15-4 1.58
DDA 17-7 1.55DDA 30-4* 3.1DDI 60-10 6.67
0.5 0.5
DMX 4-102.2DMX 8-10
DMX 16-10DMX 7-10
3.8DMX 14-10DMX 27-10DMX 9-10
4.9DMX 18-10DMX 35-10DMX 12-10
6.9DMX 26-10DMX 50-10DMH 5-10
3.5DMH 13-10DMH 24-10DMH 11-10
6.4DMH 24-10DMH 46-10
DDA/DDE 60-10 5.56
0.3 - 0.35 1.5 2.0
DDA/DDE 120-7 11.58DDA/DDE 200-4 19.3
DME 60-10** 6.25DME 150-4 15.6DDI 150-4 13.9DMX 17-4
10.4DMX 39-4DMX 75-4DMX 25-3
16DMX 60-3DMX 115-3DMX 24-8
13.8DMX 52-8
DMX 100-8DMX 142-8DMX 67-10
18.5DMX 132-10DMX 190-10DMH 21-10
11.3DMH 43-10DMH 67-10DMH 83-10
DMH 100-10
DMX 37-5
22
0.65 - 0.7 3.0 4.0
DMX 82-5DMX 160-5DMX 230-5 DMX 95-8
27.8DMX 199-8DMX 280-8DMX 60-3
36DMX 130-3DMX 255-3DMX 380-3DMX 152-6
44.6DMX 321-6DMX 460-6DMH 50-10
31.6
DMH 102-10DMH 143-10DMH 175-10DMH 213-10DMH 291-10
Pump typesPump stroke volume
[ml]
Required damper volume
Required calibration
column volume
[l]DB/DBG
[l]CSD
[l]
-
Accessories for m
edium-sized dosing pum
ps up to 460 l/h
40
Accessories for dosing pumps2
Suction-side pulsation dampers CSD with calibration scalePulsation dampers CSD are installed on the inlet side of the dosing pump. A pulsation damper CSD can be used for more than one pump at a time. They can handle pressures up to 2 bar.• Prepared for pipe gluing connection with spigot (D)
or socket (d).• Calibration is possible by installing a T-piece and a
shut-off valve.• In installations without flooded suction, the optional
manual vacuum pump kit simplifies the startup of the dosing pump. See Manual vacuum pump kit on page 41.
Pulsation dampers CSD include:• Sight glass with calibration scale• Aeration valve
Fig. 60 Pulsation damper CSD with calibration function
Dimensions
Fig. 61 Pulsation damper CSD with calibration function
Technical data
TM06
845
0 06
17
TM06
837
3 03
17
IØDØdG
HAB
CE
M
ØL
O
Damper volume[l]
A[mm]
B[mm]
C[mm]
∅D/∅d[mm]
E[mm]
G[mm]
H[mm]
I[mm]
∅L[mm]
∅M[mm]
O[mm]
0.25 50 270 360 16/12 92 14 12 40
6.5
-
8-130.5 50 340 431 16/12 92 14 12 47 -1.5 75 343 465 25/20 92 19 16 70 403.0 79 435 568 25/20 92 19 16 78 60
Damper volume
[l]
Max. pump stroke volume
[ml]
Max. number of pumps with max. stroke
volume
Scale division[ml]
Pipe connection ∅D/∅d [mm]
MaterialProduct numberBody Sight glass Gasket
0.25 2 3 2 16/12 PVC PVCFKM/EPDM 99186948
PTFE 99217401
0.5 7 3 5 16/12 PVC PVCFKM/EPDM 99187777
PTFE 99217402
1.5 19 3 20 25/20 PVC PVCFKM/EPDM 99188854
PTFE 99217403
3.0 45 2 25 25/20 PVC PVCFKM/EPDM 99190807
PTFE 99217406
-
Acc
esso
ries
for
med
ium
-siz
ed d
osin
g pu
mps
up
to 4
60 l/
h
41
Accessories for dosing pumps 2
Manual vacuum pump kitIn installations without flooded suction, the pulsation damper CSD can be filled with the manual vacuum pump kit. This makes the startup of the dosing pump easier and prepares the pulsation damper CSD for the calibration of the pump.A manual vacuum pump kit includes:• Ball valve, connection G 5/8"• T-piece, connection G 5/8"• Hose• Manual vacuum pump• Holder for wall mountingMaterials:• Vacuum pump: PVC• Ball valve and T-piece: PVC• Gasket: FKM
Fig. 62 Manual vacuum pump kit
Dimensions
Fig. 63 Manual vacuum pump kit
Order data
TM06
842
6 05
16
TM06
837
6 03
17
A[mm]
B[mm]
C[mm]
D[mm]
E[mm]
∅F[mm]
Gmin[mm]
Gmax[mm]
131 34 132.5 50 242 6.2 675 875
Description Product numberManual vacuum pump kit 99218131
AB
C G
EØ
F
D
-
Accessories for m
edium-sized dosing pum
ps up to 460 l/h
42
Accessories for dosing pumps2
Calibration columnsCalibration columns are intended for flow measurement or calibration of dosing pumps. They must be isolated from the pipework during normal operation.The volume in the calibration column can supply the largest suitable pump for approximately 30 seconds.Calibration columns include:• Glass cylinder with acrylic outer shield• Aeration valve on top• Shut-off valve on the bottomIn installations without flooded suction, the optional manual vacuum pump kit simplifies the startup of the dosing pump. See Manual vacuum pump kit on page 41.Calibration columns must not be used as pulsation dampers.
Dimensions
Fig. 64 Calibration columns
Technical data
TM06
840
5 05
17
Ød
AB
ØD
ØCmin. Hmax. H
EØF
Volume[l] Body
A[mm]
B[mm]
∅C[mm]
∅D[mm]
E[mm]
∅F[mm]
Hmin - Hmax[mm]
0.25PVDF 478 184
12 50.8 M 10 12 50-154SS 460 140
0.5PVDF 517 184
12 69.85 M 10 12 61-165SS 498 140
2.0PVDF 675 188
12 101.6 M 10 12 78-182SS 657 148
4.0PVDF 795 188
12 132 M 10 12 92-196SS 777 148
Volume[l]
Max. pump stroke volume
[ml]Scale division
[ml]
Pipe connection∅d Material Product
number[mm] [inch] Body Gasket
0.25 2 216 - PVDF FKM 99224280
- G 1/2SS FKM 99224303SS EPDM 99224304
0.5 7 516 - PVDF FKM 99224305
- G 1/2SS FKM 99224307SS EPDM 99224308
2.0 19 2025 - PVDF FKM 99224309
- G 1SS FKM 99224310SS EPDM 99224311
4.0 45 2525 - PVDF FKM 99224312
- G 1SS FKM 99224313SS EPDM 99224314
-
Acc
esso
ries
for
med
ium
-siz
ed d
osin
g pu
mps
up
to 4
60 l/
h
43
Accessories for dosing pumps 2
Vacuum pump kit for calibration columnsIn installations without flooded suction, the calibration column can be filled with the vacuum pump kit. This makes the startup of the dosing pump easier and prepares the calibration column for pump calibration.A vacuum pump kit for calibration columns includes:• Ball valve, connection G 5/8"• T-piece, connection G 5/8"• Hose• Manual vacuum pump• Holder for wall mountingMaterials:• Vacuum pump: PVC• Ball valve and T-piece: PVDF• Gasket: FKM
Dimensions
Fig. 65 Vacuum pump kit
Order data
TM06
841
2 05
17
Dimension Unit Value
Amin-max [mm] 700-875
B [mm] 242
∅C [mm] 6.1
∅D [mm] 12
E [inch] G 5/8
F [mm] 206
G [mm] 51
H [mm] 206
∅I [mm] 12
∅J [mm] 12
K [mm] 40
Description Product numberVacuum pump kit for calibration columns 99226934
FE
GH
ØI
ØJ
ØD
A m
in
A m
ax
B
ØC
K
-
Accessories for m
edium-sized dosing pum
ps up to 460 l/h
44
Accessories for dosing pumps2
Discharge-side pulsation dampers DB and DBGPulsation dampers DB and DBG have a separating diaphragm and are intended for the outlet side of the dosing pump. We recommend using one pump per pulsation damper.• Preload pressure: 2.7 bar.Pulsation dampers DB and DBG include:• Material for wall mounting• PVC versions are prepared for pipe gluing
connection with spigot (D) or socket (d).• PVDF and PP versions are prepared for pipe
welding connection with spigot (D) or socket (d).• Pulsation dampers DBG include a pressure gauge.
Fig. 66 Pulsation damper DBG with separating diaphragm and pressure gauge
Dimensions
Fig. 67 Pulsation damper DBG, PVC version
Fig. 68 Pulsation damper DB, stainless steel version
* SS 1.4404
TM06
842
4 05
17
TM06
828
4 50
16TM
06 8
452
0617
A2
A3
A1
B
min. H
max. H
EØF
ØD1ØDØd
ØD2
G
A2
A1
ØD1min. H
max. H
EØF
Nominal damper volume
[l]
Actual damper volume
[l]
MaterialPipe
connection[mm]
A1[mm]
A2[mm]
A3[mm]
D1[mm]
D2[mm]
Hmin - Hmax[mm]
Ginternal thread[inch]
F[mm]
B[mm] E
Body ∅D ∅d
0.15
0.15 PVDF 16 12 205 12 14 70 53 53-127-
12 129 M 10
0.18PVC
16 12 161 12 14 80 - 67-171PP
SS* - - 118 14 - 70 - 64-168 G 1/2
0.35
0.3 PVDF 25 20 267 20 25 84 63 58-175 -
0.36PVC
25 20 203 20 25 90 - 71-175 -PP
SS* - - 161 16 - 85 - 67-171 G 3/4
0.650.65
PVC25 20 263 20 25 100 - 78-152 -
PP
SS* - - 205 20 - 90 84 67-171 G 3/40.7 PVDF 25 20 138 20 25 125 84 67-171 -
-
Acc
esso
ries
for
med
ium
-siz
ed d
osin
g pu
mps
up
to 4
60 l/
h
45
Accessories for dosing pumps 2
Technical data
* SS 1.4404
Nominal damper volume
[l]
Max. pump stroke volume
[ml]
Pipe connectionMax. operating
pressure[bar]
Material Product number
∅D/∅d[mm]
Ginternal thread[inch]
Body GasketType DB
(without pressure gauge)
Type DBG(with pressure
gauge)
0.15 7
16/12 - 10PVC
FKM 99202642 99202679EPDM 99202653 99202680
PPFKM 99202654 99202681
EPDM 99202657 99202682
- G 1/2 180 SS*FKM 99202660 99202684
EPDM 99202661 9920268516/12 20 PVDF PTFE 99202658 99202683
0.35 19
25/20 - 10PVC
FKM 99202662 99202687EPDM 99202663 99202688
PPFKM 99202664 99202689
EPDM 99202665 99202690
- G 1/2 130 SS*FKM 99202667 99202692
EPDM 99202669 9920269325/20 20 PVDF PTFE 99202666 99202691
0.65 45
25/20 - 10PVC
FKM 99202670 99202694EPDM 99202671 99202695
PPFKM 99202672 99202696
EPDM 99202673 99202697
- G 3/4 50 SS*FKM 99202675 99202699
EPDM 99202676 9920270025/20 16 PVDF PTFE 99202674 99202698
-
Accessories for m
edium-sized dosing pum
ps up to 460 l/h
46
Accessories for dosing pumps2
Filling devices for pulsation dampers DB and DBGFilling devices for plastic or stainless-steel pulsation dampersFilling devices make the adjustment of the preloading pressure of pulsation dampers easy. The filling device is connected to a local compressed-air or nitrogen source and the filling valve of a pulsation damper. It can be removed when the pressure is adjusted.Filling devices are available with different pressure gauges.
Fig. 69 Filling device for plastic or stainless-steel pulsation dampers
Tyre-valve adapterA tyre-valve adapter allows the use of common air pumps with tyre valves for filling the pulsation damper with air.
Dimensions
Fig. 70 Tyre-valve adapter
Order data
TM06
806
8 45
16
Description Connection[inch]
Max. operating pressure
[bar]
Product number
Filling device with pressure gauge G 1/4
25 9672734260 96727343
160 96727344250 96727345
136 T
M06
814
2 47
16
A[mm]
B[inch]
C[mm]
D[mm]
25 G 1/4 38 Vg 8
Description Product numberTyre-valve adapter, up to 8 bar, for use in conjunction with compressed-air filling device or pressure gauge
96727332
A
B
C
D
-
Acc
esso
ries
for
med
ium
-siz
ed d
osin
g pu
mps
up
to 4
60 l/
h
47
Accessories for dosing pumps 2
Pump connection kits and inlay kitsRetrofit pump connection kits and inlay kits for the integration of Grundfos standard dosing pumps into installations with various sizes of hoses or pipes.A pump connection kit includes:• 1 set of inlays• 1 union nutThe inlay kits are used to connect pumps and accessories to pipes or hoses that differ from Grundfos standard sizes.An inlay kit includes:• 2 sets of inlays
Fig. 71 Pump connection kit
Fig. 72 Inlay kit
Technical data
* Union nut: SS 1.4401, inlay: SS 1.4571** 2.4610 (Alloy C-4)
TM
06 8
425
0517
TM06
843
0 05
17
Application Connection typeFor hose/pipe size Connector
type key code MaterialProduct number
Internal External Connection kit Inlay kitHose connection Nipple and clamp 19, 20 mm -
U3PP 99082037 -
Pipe connection Gluing or welding inlay - 25 mmPVC 99082038 -
PVDF 99082039 -Hose connection Cone and ring 13 mm 20 mm A6 PVC 91835696 99170747
Hose connection Nipple and clamp 19, 20 mmor 3/4" - QPP 99169576 99169735
PVC 99169603 99169740PVDF 99169728 99169738
Pipe connection Welding inlay - 25 mm B4PP 91835697 99171119
PVDF 91835698 99171146
Pipe connection Gluing inlay -
25 mm B0 PVC 96701989 991711773/4" pipe (US)
or26.6 mm (BS)
C7 PVC 99170858 99171222
Pipe connection External thread 3/4" NPT A7PVC 99082040 99171707PP 99082041 99171776
PVDF 99082042 99171793
Pipe connection Internal thread
Rp 3/4" A1
PP 99082043 99182104PVDF 99082044 99182109
SS* 99082045 99182114
Alloy C-4** 99082046 99182136
3/4" NPT A3
PP 99082047 99174974PVDF 99082048 99175004
SS* 99082049 99175015
Alloy C-4** 99082050 99175031
Pipe connection Cutting-ring type 19 mm 22 mm C3 SS* 96727555 -
-
Accessories for m
edium-sized dosing pum
ps up to 460 l/h
48
Accessories for dosing pumps2
Electric stirrersElectric stirrers are intended for the mixing and dissolving of non-abrasive, non-inflammable and non-explosive liquids. They ensure that the liquid in the dosing tank is mixed constantly. With a frequency of 50 Hz they run at approximately 1500 rpm. Electric stirrers are suitable for liquids with low to medium viscosity.Different versions of electric stirrers are available:• Stainless steel version (SS)• PP version with or without sealing flange• Versions for various tank sizes from 60 litres up to
1000 litres
Dimensions
Fig. 73 Electric stirrer, stainless steel version Fig. 74 Electric stirrer, PP version with sealing flange
Technical data
TM04
863
8 41
12
16
D
AL (
SS
)P
BC
F
E
TM04
863
9 41
12
20
D
PL (
PP
)A
15
FCB
E
Tank size[l]
L(SS)[mm]
L(PP)[mm]
A[mm]
B[mm]
C[mm]
D[mm]
E[mm]
F[mm]
P[mm]
60 450 452 210 140 115 88 9 95 25 100 691 693 210 140 115 88 9 95 25 200 698 700 191 160 130 100 9 110 25 300 950 952 191 160 130 100 9 110 25 500 1100 1102 191 160 130 125 9 110 28
1000 1150 1152 231 200 165 125 11 130 28
Tank size [l]
Nominal shaft length [mm] Material, type
Product number
Single-phase motor Three-phase motor
60 450SS 98164569 98165309PP 98164573 98165310
PP, with sealing flange 98164575 98165318
100 690SS 98164606 98165355PP 98164607 98165357
PP, with sealing flange 98164609 98165382
200 690SS 98164987 98165385PP 98164990 98165386
PP, with sealing flange 98165152 98165391
300 950SS 98165172 98165393PP 98165175 98165