Green technology used for Green technology used for ATLAS processing ATLAS processing
Dr. Ing. FDr. Ing. Făărcarcaşş Felix [email protected]@itim-cj.ro
NATIONAL INSTITUTE FOR RESEARCH AND DEVELOPMENT OF ISOTOPICNATIONAL INSTITUTE FOR RESEARCH AND DEVELOPMENT OF ISOTOPIC AND MOLECULAR TECHNOLOGIESAND MOLECULAR TECHNOLOGIES
Donath St. 65-103, 400293, Cluj-Napoca, ROMANIADonath St. 65-103, 400293, Cluj-Napoca, ROMANIA Tel.: +40-264-584037; Fax:Tel.: +40-264-584037; Fax: +40-264-420042; GSM: +40-731-030060+40-264-420042; GSM: +40-731-030060
e-mail: e-mail: [email protected], web: , web: http://www.itim-cj.ro
22
Why may we use “Green” Why may we use “Green” Technology in a datacenter Technology in a datacenter
especially for Grid?especially for Grid?
INCDTIM
33
Green IT
Green use. Reduce the energy consumption of computers and other information systems.
Green disposal. Refurbish and reuse old computersGreen manufacturing. Manufacture of electronic components and other subsystems with minimal or no impact on the environment
Green design. Design energy efficient and environmentally sound computers, servers, and cooling equipment.
INCDTIM
44
ITIM Datacenter dedicated to Grid
Place for max 5 rack’s, total of 200 1U rack mountable computers
To small for our expectation 5 years ago, but good for a start.
No backup solution, no redundancy
INCDTIM
55
We used some of the green IT concepts
Green disposal– less space more computers– good management program, less
people, – redundant system
Green use– power economy– using virtual environment on 5
Years old rack mountable computers
INCDTIM
66
Technology and ImplementationTechnology and Implementation INCDTIM
77
Blade technologyBlade technology
IBM and HP Blade system, total of IBM and HP Blade system, total of 46 46 Blades in only Blades in only 29 U29 UProcessing power: Processing power: 368 368 corecoreLess space for 46 PC => Less space for 46 PC => core increase by core increase by 56%56%Less Less powerpower consume consume reduced reduced by by 34%34%Management -> through web based Management -> through web based interfacesinterfacesMSA Storage capacity: 50 TB, MSA Storage capacity: 50 TB,
INCDTIM
Blade system and MSA storage
88
Network Layer 3 Switch Cisco Network Layer 3 Switch Cisco 6509E6509E
A Layer 3 switch with A Layer 3 switch with routing capabilities routing capabilities -> -> decrease power consumedecrease power consume
Full redundant system -> Full redundant system -> increase reliabilityincrease reliability
ITIM – RoEduNet 10 GB 2011ITIM – RoEduNet 10 GB 2011
INCDTIM
99
Backup and monitoringBackup and monitoring
Power generator 275kW
APC Netbotz Monitoring System
Temperature
Humidity
Fluid detector
Smoke detector
Uninterruptible Power Source ~ APC Symetra of
max 160 KVA full redundant
INCDTIM
U
P
S
1010
Logical Schema of the DatacenterLogical Schema of the Datacenter Network Configuration Network Configuration
INCDTIM
RO-14-RO-14-ITIM ITIM
ResultsResultsfor Atlas for Atlas
in in RomaniaRomania
1111
INCDTIM
1212
17% of CPU time in Romania17% of CPU time in RomaniaINCDTIM
1313
What are the Green IT implementations results?
Did we increase the number of Cores in the Datacenter? - Yes
Did we Improve the management condition – Yes
Do we have good redundancy? – Yes
Did we Reduce the power consumption? … Maybe
INCDTIM
1414
Financial supportFinancial support
1.1. Fund through National Authority for Science Fund through National Authority for Science Research (ANCS)Research (ANCS)
2.2. SINDEGRIDSINDEGRID, closed project , closed project 3.3. 12 EU12 EU – ConDeGrid / 2009 – present – ConDeGrid / 2009 – present4.4. 15 EU15 EU / 2008 – present / 2008 – present5.5. POS-CCEPOS-CCE 192/2719 192/2719, , Sectorial Operational Sectorial Operational
Program, “Increase of Economic Program, “Increase of Economic Competitiveness”, Competitiveness”, contract 42/11.05.2009 contract 42/11.05.2009 Axis 2, Operation 2.2.3~ Axis 2, Operation 2.2.3~ Improving the Improving the capacity and reliability of INCDTIM GRID capacity and reliability of INCDTIM GRID center for integration in international center for integration in international networks (INGRID)networks (INGRID), , ValueValue: 2.345.800 lei: 2.345.800 lei ~ ~ 500.000 Euro500.000 Euro
6.6. POS-CCE 536, Axis 2, operation 2.1.2, POS-CCE 536, Axis 2, operation 2.1.2, software acquisition. software acquisition.
7.7. Cooperation programCooperation program "Hulubei- "Hulubei-Meshcheryakov“ together with the Laboratory Meshcheryakov“ together with the Laboratory of Information Technologies at JINR –Dubnaof Information Technologies at JINR –Dubna
INCDTIM
Conference InvitationConference InvitationINCDTIM is organizing between the INCDTIM is organizing between the 25-27 25-27 OctoberOctober 2012 2012 the the Fifth Romania Tier 2 Fifth Romania Tier 2 Federation "Grid, Cloud & High Performance Federation "Grid, Cloud & High Performance Computing Science" - RO-LCG ConferenceComputing Science" - RO-LCG Conference
http://www.itim-cj.ro/rolcg2012
Under the Regis of: Under the Regis of: IEEE Romania IEEE Romania SectionSection– Full paper submission: 2Full paper submission: 25.07.20125.07.2012– Notification of acceptance: Notification of acceptance: 1.09.20121.09.2012– Camera ready papers: Camera ready papers: 15.09.201215.09.2012 1515
INCDTIM
1616
?Future idea?
We are We are improving the storage improving the storage capacity for capacity for analyzing ATLAS data in the near futureanalyzing ATLAS data in the near future
Virtual implementation
We are looking to improve the middleware. We are looking to improve the middleware. and changing and changing gLite to EMgLite to EMII
Improving the IPv6 link
Working for obtaining new collaboration for the Grid site