8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67
1/65
ZXSDR BTS Structure and Principle
-
8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67
2/65
Agenda
ZXSDR BTS Fam ily Introduc t ion
ZXSDR BS8700
ZXSDR BS8800
ZXSDR BS8900 ZXSDR BS8906
ZXSDR BTS Work Principle
ZXSDR BTS Operation and Maintenance
-
8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67
3/65
Evolution of Multi-Mode BTS
ZTE macro-BTS, IP
architecture, 18TRX cabinet
Traditional macro-BTS, ATM
architecture, 12TRX cabinet
Different BTS systems
overlapped
TDM/ATM platform
Narrowband architecture
Low integration and high
consumption
G1 Multimode
BTS
Different BTS SystemsInterchanged
3G BBU/RRU Interchangeable
IP/ATM architecture
Increasing integration
G2 Multimode
BTS
Shared broadband multi-carrier module
Shared uTCA BBU
Full-IP architecture and unified platform
Multi-system conversion for same frequency
softwareUltra-high integration and low consumption
G3 Multimode
BTS - SDR
Unified Radio Resource
Management
System conversion for
adjacent frequency software
Integrated BSC function
MESH network Architecture
G4 Multimode
BTS - Flat SDR
ZTE SDR, 36TRX cabinet
-
8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67
4/65
ZTE SDR Base Station Platform
Multiple mode, multiple frequency
band, unified hardware platform
Base band processing unit based
onTCA structure
SDR helps you to achieve:
Optimizedfrequency resource utilization Optimized networkresource
Smooth innovation of wirelessnetwork Best networking solution forTCO
Separate baseband and radio
Radio unit based on MCPA
CDMA2000
GSM TD-SCDMA
WiMAX
WCDMA
-
8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67
5/65
ATCA/mTCA
ATCA (Advanced Telecommunication Computer Architecture):
adopted by PICMG in 2003
Micro TCA (u TCA): ATCA, be fit for accessing network
-
8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67
6/65
Broadband MCPA
Single-Carrier PA Multi-Carrier PA
Combiner & Antenna
Interface
Digital IF Process
BBU
PA1
TRX1
PA2
TRX2
PA3
TRX3
PA4
TRX4
f1 f2 f3 f4
Duplex & Antenna
MCPA
MTRX
Interface
BBU
Digital IF Process
f1~f6)
f1~f6)
SDR design is based on MCPA at the same frequency;
MCPA provides flexible frequency optimization technology and better equipment integrity.
-
8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67
7/65
BS8700
BS8900
BS8800
Distributed BTS BS8700, flexiblenetworking, 0 space requirement and
rapid deployment , can be used for both
indoor and outdoor coverage
B8200
R8860
RSU40/RSU60
+
+ =
Indoor Marco BTS BS8800, can be
installed in equipment room for indoor
coverage
RSU40/RSU60
+ =
Outdoor Marco BTS BS8900, can be
installed in cabinet for outdoor
coverage, it can adapt to various
environment
=
B8200
B8200
Micro BTS BS8906, provide Low-cost
integrated solution for single-sectorcell.
BS8906
+ =B8200
RSU40/RSU60
R8840
SDR Base Station Family
-
8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67
8/65
RRUBBU
Indoor Macro
Outdoor
Macro
MCPA-basedbroadband Radio
Unit with multi-mode supported.
Sufficient output power of HPA
with lower power consumption.
MicroTCA structureBase Band
Unit with high reliability and
easy expansion.
High integrity & processing
capability; upgrade to HSPA+ via
software; minimum upgrade cost
to support LTE.
ZTE SDR 4 Key Features
ZTE GSM/UMTS Dual-Mode SDR Family
-
8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67
9/65
Agenda
ZXSDR BTS Family Introduction
ZXSDR BS8700
ZXSDR BS8800 ZXSDR BS8900
ZXSDR BS8906
ZXSDR BTS Work Principle
ZXSDR BTS Operation and Maintenance
-
8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67
10/65
Hardware Architecture of BS8700
B8200
+R8840
R8860
BS8700
Fiber
BBU
Radio UnitRadio Unit
SA/
SE
CC
BB
(uBPG)
FS R8860
E1(75
/120)
/ T1
GE/FE
Clock
Data
Control Signaling
Antenna
RRU
CPRI
The structure of BS8700 can express in the form of
BBU+RRU, with Base band and RF modules separated.
-
8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67
11/65
B8200 accomplishes the following basic functions
with RRU in Um/Uu, Abis/Iub and O&M interfaces. RRU and B8200 accomplishes UE access and radio link transmission
including RF processing, channel coding and decoding, channel
multiplexing and de-multiplexing, measuring and reporting, power
control, transmit diversity, receiving diversity, calibration and
synchronization. With Abis/Iub interface, RRU and B8200 connects with BSC/RNC and
accomplishes the following functions including cell management,
reporting BTS measurement information, broadcasting system
Information, implementing access control from BSC/RNC, mobility
management, radio resource management and controlling, FP
processing and transmission management.
With operating and maintenance interface, B8200 provides system
management functions including configuration management, alarm
management, status checking and system monitoring
ZXSDR B8200 Introduction
-
8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67
12/65
Based on Unified MicroTCA Platform
Base Band Unit - ZXSDR B8200
Volume:
88.4482.6197mmHWD
Weight: 8.75kg (full configuration)
Typical Power Consumption :
GSM 60W/12TRX
WCDMA 80W / 6CS
Power Supply: -48V DC
Temperature Range: -2055
Humidity Range: 5%95%
2U
482.6mm
88.4mm
GSM Processing Capability:
60TRX (12TRX *5uBPGs )
24 Cell / BBU
UMTS Processing Capability:
960CE/BBU(192CE/BPC*5)
Throughput UL 75Mbps(15Mbps*5)
Throughput DL 216Mbps(43.2Mbps*5)
30CS/BBU
Abis/Iub Interface:
16*E1/T1
1*FE/GE Electric/Optical(8 VLAN)
To RRU: 12*1.25Gbps CPRI optical interface
Performance Index
Physical IndexInterface Index
19 inch
-
8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67
13/65
PM Board Introduction
Power Module
16 internal interface for +12V load power
16 internal interface for +3.3V management power
Measurement and protection of input over-voltage/under-voltage;
Output over-current protection and load power management
Power Module
-
8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67
14/65
Board LED Color Meaning Description
PM
RUN GreenRunning
Indicator
Always on: The board is in reset state.Flashing at 1Hz: The board is normally running.
Off: Self test fails.
Alarm Red Alarm IndicatorOn: The board has an alarm.
Off: The board has no alarm.
HS BluePlugging/Unplug
ging Indicator
On: The board can be unplugged.
Flashing: The board is being activated or
deactivated.
Off: The board cannot be unplugged.
PM Indicators
-
8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67
15/65
SA/SE Board Introduction
Site Alarm Board
Site Alarm Board/Site Alarm Extender Board(optional)
Alarm monitor and rev control of no more than 9 fans;
Signal monitor and interface lightning protection for the rack;
Providing 6 input dry contact interfaces, 2 input /output dry contact interface;
Providing 8 lines of E1/T1 interface
-
8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67
16/65
Board LED Color Meaning Description
SA/SE
RUN GreenRunning
Indicator
Always on: The board is in reset state.
Flashing at 1Hz: The board is normally running.
Off: Self test fails.
Alarm Red Alarm IndicatorOn: The board has an alarm.
Off: The board has no alarm.
HS BluePlugging/Unplug
ging Indicator
On: The board can be unplugged.
Flashing: The board is being activated or
deactivated.
Off: The board cannot be unplugged.
SA/SE Indicators
-
8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67
17/65
SA JumpersJumperX5 is used to set E1/T1 transmission mode.
TWO LSB POSITIONS OF X5
TWO MSB POSITIONS OF X5
-
8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67
18/65
CC Board Introduction
GPS system clock & RF reference clock;
Abis Iub interface function;
Ethernet switch function, providing switch plan for signaling and media stream;
Rack management
Control & Clock Board
-
8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67
19/65
Board LED Color Meaning Description
CC
HS BluePlugging/Unpluggin
g Indicator
On: The board can be unplugged.
Flashing: The board is being activated or deactivated.
Off: The board cannot be unplugged.
RUN Green Running Indicator
Always on: The board is in reset state.
Flashing at 1Hz: The board is normally running.
Off: Self test fails.
Alarm Red Alarm Indicator On: The board has an alarm.Off: The board has no alarm.
E0S Green E1/T1 statusindicator (link 03)
Alternate flash for different links; the max 4 flashes per
second; flashing at frequency of 5 Hz.
The first second: one flash means Link 0 is normal and
OFF means Link 0 is not in use.
The third second: two flashes means Link 1 is normal and
OFF means Link 1 is not in use.The fifth second: three flashes means Link 2 is normal
and OFF means Link 2 is not in use.
The seventh second: four flashes means Link 3 is normal.
and OFF means Link 3 is not in use.
Recycle. Each cycle lasts for eight seconds.
CC Indicators
-
8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67
20/65
Board LED Color Meaning Description
CC
E1S Green E1/T1 statusindicator (link 47)
The same as E0S.
E2S GreenE1/T1 status
indicator (link 811)The same as E0S.
E3S Green
E1/T1 status
indicator (link 12
15)
The same as E0S.
MS Green Active/Standbystatus indicator
On: The board is in active statusOff: The board is in standby status
REF Green
GPS antenna state
or 2 MHz state,
connection state ofSMA Interface on
corresponding
panel GPS
Always on: The antenna feeder is normal.
Always off: The antenna feeder and satellite are normal,
in initialization state.
Slow Flash (flashing at 1 Hz)): The antenna feeder is
broken.
Fast Flash (flashing at 2 Hz): The antenna feeder is
normal but cannot receive satellite signal.
Slowest Flash (flashing at 0.5 Hz): Antenna short circuit
Quickest Flash (flashing at 5 Hz): No message is
received at the initialization stage.
CC Indicators
-
8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67
21/65
Board LED Color Meaning Description
ETH0 GreenAbis/Iub interface
link state
On: Physical link of Abis/iub network interface
(optical or electrical) is normal.
Off: Physical link of Abis/Iub network interface is
broken.
ETH1 Green
Link state of
ETH1 networkinterface
On: Physical link of network interface is normal.
Off: Physical link of network interface is broken.
CC Indicators
-
8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67
22/65
FS Board Introduction
Fabric Switch Board
Fabric Switch Module
Baseband IQ data exchange;
Providing interface between RRU and BBU
-
8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67
23/65
Board LED Color Meaning Description
FS
RUN GreenRunning
Indicator
Always on: The board is in reset state.
Flashing at 1Hz: The board is normally running.
Off: Self test fails.
Alarm Red Alarm IndicatorOn: The board has an alarm.
Off: The board has no alarm.
HS BluePlugging/Unplug
ging Indicator
On: The board can be unplugged.
Flashing: The board is being activated or
deactivated.
Off: The board cannot be unplugged.
FS Indicators
-
8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67
24/65
-
8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67
25/65
Board LED Color Meaning Description
UPBG
RUN GreenRunning
Indicator
Always on: The board is in reset state.
Flashing at 1Hz: The board is normally running.
Off: Self test fails.
Alarm Red Alarm IndicatorOn: The board has an alarm.
Off: The board has no alarm.
HS BluePlugging/Unplug
ging Indicator
On: The board can be unplugged.
Flashing: The board is being activated or
deactivated.
Off: The board cannot be unplugged.
UPBG Indicators
-
8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67
26/65
Cable Connection of B8200
-
8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67
27/65
ZXSDR R8860 Introduction
Support the configuration of 5MHz/4.8MHz/4.6MHz channel interval;
Multi-carrier support: GSM up to 6 carriers, UMTS up to 4 carriers, GSM/UMTSdual mode configuration;
Multi-band support: 900M/1800MMHz
Co-cabinet can support 4-antenna-receiving in 1 sector;
Co-cabinet can support transmit diversity, without adding antenna achieving same
receiving sensitivity;
Co-cabinet can support non-continuous frequency configuration;
Support RTWP report interval at 100ms and 2ms;
Support transmit power reporting function for every carrier;
Support over loading protection function for power amplifier;
Support measurement, compensation and adjustment function for channel delay;
Support transmit channel switching on/off function;
R8860 software fault for itself will not affect the running of BBU and other R8860
which connected to it.
-
8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67
28/65
Remote Radio Unit - ZXSDR R8860
SDR R8860
Carrier Configuration:
Support GSM 1-6TRX or UMTS 1~4 CS
Output Power60W /80W
Receive Sensitivity:
GSM -113dBm@sigle antenna
UMTS
-126.5dBm@sigle antenna
-129.2dBm@dual antenna
Frequency:
900MHz, 1800MHz, 850MHz, 1900MHz
Performance Index
2*1.25G CPRI Optical interface
Interface Index
Volume(R8860): 500320172mmHWD
Weight: 22.5Kg
Typical Power Consumption:200W (6TRX)(900M)
Power Supply: -48V DC
Temperature Range:-40+55
Protection Class:IP65
Physical Index
500mm
35 power-efficient for GSM
40% power-efficientfor UMTS.
Support GSM and UMTS.
-
8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67
29/65
Remote Radio Unit Interface
No Label Interface
1 LC1BBU and RPU Interfaces / RRU
concatenation interface
2 LC2BBU and RPU Interfaces / RRU
concatenation interface
3 AISG AISG device interface
4 Mon External device interface
5 DC IN Power interface
6 RXInterface to receive diversity RF
cable
7 RX/TXInterface to transmit / receive main
diversity RF cable
8 RXout Frequency expansion interface
9 RXin Frequency expansion interface
10 GND Machine Grounding
-
8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67
30/65
Board LED Color Meaning Description
RRU
RUN Green Running Indicator
Always on: The board is in resetting or starting status.
Flashing at 1Hz: The board is normally running.
Flashing at 5Hz: The board is downloading version.
Off: Self test fails.
Alarm Red Alarm Indicator
Flash in 5Hz: critical or severe alarm
Flash in 1Hz:normal or minor alarm
Off: The board has no alarm.
Link GreenOptical link
indicator
On: normal fiber connection
Off: disconnected fiber
Flash in 5Hz: consider this link as clock reference source,
and phase-locked loop in fast capture status
Flash in 0.25Hz: consider this link as clock reference
source, and phase-locked loop in trace status
RF OrangeRF working status
indicator
Off: without RF out put
On: with RF out put
RRU Indicators
-
8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67
31/65
-
8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67
32/65
Agenda
ZXSDR BTS Family Introduction ZXSDR BS8700
ZXSDR BS8800
ZXSDR BS8900 ZXSDR BS8906
ZXSDR BTS Work Principle
ZXSDR BTS Operation and Maintenance
-
8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67
33/65
ZXSDR BS8800 Introduction
ZXSDR BS8800 (hereafter BS8800) is one of multi-carrier, multi-mode indoor
macro base station in ZXSDR BTS series. BS8800 accomplishes UE access and radio link transmission including RF
processing, channel coding and decoding, channel multiplexing and de-
multiplexing, measuring and reporting, power control, transmit diversity, receiving
diversity, calibration and synchronization.
BS8800 connects with BSC/RNC and accomplishes the following functions
including cell management, reporting BTS measurement information, broadcastingsystem Information, implementing access control from BSC/RNC, mobility
management, radio resource management and controlling, FP processing and
ATM transmission management.
With operating and maintenance interface, BS8800 provides system management
functions including configuration management, alarm management, status
checking and system monitoring.
BS8800 adopts standard 19 inches rack structure. The volume is main cabinet
dimension: 950mm * 600mm * 450mm (H*W*D), auxiliary cabinet dimension:
700mm * 600mm * 450mm (H*W*D).
-
8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67
34/65
Integrated Indoor Macro Site - ZXSDR BS8800
Radio Unit
Baseband
Unit
Radio Unit:
RSU40/RSU60
Physical Index
Volume: 950600450mmHWD
(Main Cabinet)
Weight: 135kg (Main Cabinet)
Typical Power Consumption S666:735W(RSU60)
Power Supply: -48V DC (-40~-57V DC)
Performance Index
GSMProcessing Capability:
GSM: 60 TRX (12TRX * 5 BP boards
24 Cell / BBU
UMTS Processing Capability:
Uplink and Downlink: 960CE
UMTS: 30CS (6CS * 5 BPC boards)
Receive Sensitivity:
GSM -113dBm@single antenna
UMTS-126.5dBm@sigle antenna
UMTS-129.2dBm@dual antenna
Interface IndexIub Interface:
8*E1/T1(Can expand to 16)
1*GE/FE Optical or 1*GE/FE Electrical
To RRU: 12 *1.25Gbps CPRI Optical Interface
SDR BS8800
B8200
-
8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67
35/65
Radio Unit of BS8800- RSU40/RSU60
RSU40/RSU60 is an radio unit of BS8800 based on MCPA
technology. It consists of MCPA (multi-carrier power module)
module, transceiver module, and duplex filter LNA, and
connects antenna via TX/RX, RX port.
Compact and light
Feeder Interface
CPRI optical to
BBU, or connect
via SFP high-
speed cable
RX expand
interfaceNumbe
rInterface Interface Description
1 Power Power supply interface
2 AISG AISG device interface
3 Mon External device interface45 TestDBG Debug, test interface
6 TX RXInterface between BBU and
RRU or RRU cascade
7 RXoutRXin Frequency expand interface
8 ANT
Main and diversity antenna
interface
-
8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67
36/65
-
8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67
37/65
38
Radio Unit:
RSU40,RSU60
Wiring Duct:
Used to walk wiring in rack, such as
fiber or SFP cable between BBU
and RSU.
Power Distribution Module:
Passive power distribution unit
Transmission Device: 1U slot, it can provide built-in
transmission or microwave devices
to save operators investment.
Base Band Unit:
2*B8200 can be placed in
maximum FAN
Used to perform heat dissipation for
RSU modules, 6 fans in total
BS8800 Hardware Structure
950mm
600mm
450 mm
Radio Unit
Power
Distribution Module
Wiring
Duct
Transmission
DeviceVentilation
Base Band
Fan
-
8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67
38/65
Easy to stack and expand, lower upgrade cost for customers
BS8800 - Easy to Stack, Easy to expand
1650mm
450 mm
600mm
Power Distribution
Module
Cable Chute
Base Band Unit
950mmPower Distribution
Module
Cable Chute
Radio Unit
Auxiliary Cabinet Fan
Radio Unit
Ventilation
Main Cabinet
950mm
600mm
450 mm
600mm
450 mm
700mm
Ventilation
-
8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67
39/65
Agenda
ZXSDR BTS Family Introduction ZXSDR BS8700
ZXSDR BS8800
ZXSDR BS8900 ZXSDR BS8906
ZXSDR BTS Work Principle
ZXSDR BTS Operation and Maintenance
-
8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67
40/65
ZXSDR BS8900 Introduction
ZXSDR BS8900 (hereafter BS8900) is one of multi-carrier, multi-mode outdoor
macro base station in ZXSDR BTS series.
BS8900 accomplishes UE access and radio link transmission including RF
processing, channel coding and decoding, channel multiplexing and de-
multiplexing, measuring and reporting, power control, transmit diversity, receiving
diversity, calibration and synchronization.
BS8900 connects with BSC/RNC and accomplishes the following functions
including cell management, reporting BTS measurement information, broadcasting
system Information, implementing access control from BSC/RNC, mobility
management, radio resource management and controlling, FP processing and
ATM transmission management.
With operating and maintenance interface, BS8900 provides system management
functions including configuration management, alarm management, status
checking and system monitoring.
BS8900 adopts standard 19 inches rack structure, is composed of outdoor RF
cabinets RC8910, RC8911, RC8931, site support cabinet BC8910, and battery
cabinet PC8910.
Integrated Outdoor Macro Site ZXSDR
-
8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67
41/65
Integrated Outdoor Macro Site - ZXSDR
BS8900
Radio Unit:
RSU40/RSU60
Physical Index
Volume: 1900600600mmHWD
(Standard Configuration)
Weight: 220kg ( with 3RSU)
Typical Power Consumption:S666:725W(RSU60)
Power Supply: -48V DC(-40VDC ~ -57VDC)
Interface IndexIub interface:
8*E1/T1(Can expand to 16)
1*GE Optical or 1*GE/FE Electrical
To RRU: 12 *1.25Gbps CPRI Optical interface
SDR BS8900Base Band Unit:
B8200Performance Index
GSM Processing Capability:
GSM: 60 TRX (12TRX * 5 BP boards)
24 Cell / BBU
UMTS Processing Capability:
Uplink and Downlink: 960CE
UMTS: 30CS (6CS * 5 BPC boards)
Receive Sensitivity:
GSM -113dBm@single antenna
UMTS-126.5dBm@sigle antenna
UMTS-129.2dBm@dual antenna
-
8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67
42/65
-
8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67
43/65
Cabinet Appearance
supporting cabinet + battery cabinet and radio cabinet
Outdoor Radio Cabinets
RC8910Radio Cabinet
BC8910
Supporting
cabinetPC8910
Battery Cabinet
Power & Battery Cabinets
RC8931
Radio Cabinet
RC8911
Radio Cabinet
-
8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67
44/65
BC8910 Structure
Heat Exchange 4U
Reserve Max. 6U
BBU 2U
AC Power 6U
Heat Exchange 4U
Reserve 6U/7U
BBU 2U
PDM 3U
Lighting box 1U/2U
Wiring Duct1U
AC Supply DC Supply
-
8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67
45/65
RC8911&RC8910 Structure
RU
Fan subrack
PDM
Storage battery
Base
Fan subrack
PDM
Breaker
and surge arrester
RU
Base
RC8911 RC8910
RC8931&PC8910 S
-
8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67
46/65
RC8931&PC8910 Structure
RU
Fan subrack
Storage battery
Base
PDM
Base
Storage battery
RC8931
PC8910
-
8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67
47/65
AC Configuration:BC8910+RC8911+RC8931
Fan subrack
BC8910
RC8911
RC8931
Site support cabinet BC8910: used to
accommodate power system, baseband pool unit,
heat exchanger, and transmission device.
Outdoor RF cabinet RC8911: used to accommodate RF unit and battery.
Outdoor RF cabinet RC8931:
used to accommodate RF unitand battery.
Heat
Exchanger
BBU
B121
Fan
subrack
PDM
RU
Storage
battery
PDM
RU
Storage
battery
6U reserved
space
AC
-
8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67
48/65
RC8910
AC
Configuration:BC8910+RC8910+RC8911+PC8910
PC8910
BC8910
Heat
Exchanger
BBU
B121
Fan
subrack
PDM
RU
Storage
battery
Fan
subrack
PDM
RU
6U reserved space
RC8911
Outdoor RF cabinet RC8910:
used to accommodate RF unit.
Outdoor RF cabinet PC8910:
used to accommodate battery.
Storage
battery
-
8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67
49/65
AC Configuration:BC8910+PC8910+RRU
PC8910
BC8910
R8860
Heat
Exchanger
6U reserved space
BBU
B121
Storage
battery
-
8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67
50/65
BC8910
RC8910
DC Standard Configuration:BC8910+nRC8910
BBU
Heat
Exchanger
RU
PDM
Fan
subrack
n=1~3
-
8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67
51/65
52
Multi-form, Minimal Requirement for Site Condition
2
3
4
1
Place cabinets side by side
RRU Remote Application
Compact Configuration
High Integration
Built-in transmission,
battery, power supply
Maximal 8-hours
power supply in full
configuration
Same size, volume and space for
all cabinets
Suitable for these scenarios such as
ground-bearer or limited height
No Power cabinet Compact
Power and battery are optional
based on different conditions.
RRU makes RF as close to
antenna as possible, minimizing
feeder loss.
-
8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67
52/65
Agenda
ZXSDR BTS Family Introduction ZXSDR BS8700
ZXSDR BS8800
ZXSDR BS8900 ZXSDR BS8906
ZXSDR BTS Work Principle
ZXSDR BTS Operation and Maintenance
-
8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67
53/65
ZXSDR BS8906 Introduction
ZXSDR BS8906 (hereafter BS8906) is one of multi-carrier, multi-mode outdoor
micro base station in ZXSDR BTS series.
BS8906 accomplishes UE access and radio link transmission including RF
processing, channel coding and decoding, channel multiplexing and de-
multiplexing, measuring and reporting, power control, transmit diversity, receiving
diversity, calibration and synchronization.
BS8906 connects with BSC/RNC and accomplishes the following functions
including cell management, reporting BTS measurement information, broadcasting
system Information, implementing access control from BSC/RNC, mobility
management, radio resource management and controlling, FP processing and
ATM transmission management.
With operating and maintenance interface, BS8906 provides system management
functions including configuration management, alarm management, status
checking and system monitoring.
The BS8906 consists of BBU, RSU, FCE, PSU, APM\DPM, LPU\SDH\microwave
IDU and so on.
I t t d Mi Sit ZXSDR BS8906
-
8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67
54/65
Integrated Micro Site - ZXSDR BS8906
Radio Unit:
RSU40/RSU60
Physical IndexVolume: 600 320 480 mmHWD
Weight: 52kg
Typical Power Consumption S4: 300W (RSU60)
Power Supply: -48V DC (-40~-57V DC)
Performance Index
Processing Capability:
GSM: 6TRX,UMTS 4CS
Base Band Processing Capability:
Same as B8200
Receive Sensitivity:
GSM -113 dBm@sigle antenna
UMTS-126.5dBm@sigle antenna
Frequency
900MHz, 1800MHz, 850MHz, 1900MHz
Interface IndexIub Interface:
8*E1/T1(Can expand to 16)
1*GE/FE Optical or 1*GE/FE Electrical
To RRU: 12 *1.25Gbps CPRI Optical Interface
SDR BS8906
B8200
BS8906 can be connected with RRU
for outdoor BBU solution.
-
8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67
55/65
-
8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67
56/65
Agenda
ZXSDR BTS Family Introduction ZXSDR BS8700
ZXSDR BS8800
ZXSDR BS8900 ZXSDR BS8906
ZXSDR BTS Work Princip le
ZXSDR BTS Operation and Maintenance
-
8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67
57/65
Hardware Architecture
BBU performs Abis/Iub interface functions, signaling processing,baseband
processing, remote and local O&M functions, working status monitoring, andalarm functions.
RRU performs terminal access and RF link transmission function through
Um/Uu interface.GPS antenna
SAE1/T1
BSC/RNC
IQ
switching
IQGE
RRU
FAM
PM
Abis/Iub
Clock
GE/FE
GE
UBPG/ BPC
FS GE
switching
CC
Fiber
BBU
-
8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67
58/65
Software Architecture
OSS
G SM Function
UMTS Function
NOP
OMC-B
SCS OAM DBS BRACSBRS
VOS
Sche. Timer Moni. CPP Excep Mem BBX File DBG
Windows
Hardware (BSP)
VxWorks
LMT
-
8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67
59/65
The operating support layer provides the functions of OSS, OAM, DBS, BRS, BRACS, and
SCS to serve to different BTS mode. OAM (Operating and Maintenance) is to provide the configuration, alarm and
performance measurement function.
DBS (Data Base Sub-system) is the database system.
BRS (Barrier Sub-system) is for protocol stack processing.
BRACS (Barrier Access Control Sub-system) is to control the access to bear layer.
SCS (System Control Sub-system) is to control the power supplying andactive/standby switching.
OSS (Operation Support Sub-system) is the support layer in this entire framework, which is
a hardware irrespective platform for running software and provides basic functions like
scheduling, timer, memory management, communication, sequencing control, monitoring,
alarming and logging. Detects the external and internal environment temperature in real
time.
BSP (Board Support Package) supports the information routing to the GSM and public
parts in the application layer.
VxWorks is the operation platform communication to the hardware components.
Software Architecture
-
8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67
60/65
Agenda
ZXSDR BTS Family Introduction ZXSDR BS8700
ZXSDR BS8800
ZXSDR BS8900 ZXSDR BS8906
ZXSDR BTS Work Principle
ZXSDR BTS Operat ion and Maintenance
-
8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67
61/65
-
8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67
62/65
Maintenance Functions
FaultManagement
NE (RAN)
3rd Party
NMS/OSS/BSS
CORBA SNMP FILE ASCII DB
PerformanceManagement ConfigurationManagement
Log
Management
Security
Management
Northbound
Interface
Version
Management
System
Management
Topology
Management
FM
NE (CN)
Southbound
Interface
PM CM IM SM
NE
EMS
NMS/OSS/
BSS
NetNumenTMM31
FM FM/PM/CM/IMFM/PM/CM/IM FM FM/PM/CM/IM
FM PM CM IM SM
-
8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67
63/65
The BSS provides a transparent channel to implement operation and maintenance
information interaction between NetNumen M31 and the BTS. Management of the BSC and
the BTS adopts unified client interface for unified security management and operation log.
And it has a unified service management interface. NetNumen M31 also supports
CORBA/SNMP Itf-N interface to be integrated with third-part NMS.
Maintenance Functions
Version Management
With this function, users can check the versions of the software and hardware running at
the foreground. The background provides a software downloading system for software
upgrade at the foreground. Before downloading, warehousing processing is required, that is,
copying the version file to the server and registering to the server.
Fault Management
With this function, users can check the versions of the software and hardware running at
the foreground. The background provides a software downloading system for software
upgrade at the foreground. Before downloading, warehousing processing is required, that is,
copying the version file to the server and registering to the server.
-
8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67
64/65
Maintenance FunctionsConfiguration Management
Configuration management implements equipment configuration and radio configuration.
Log Management
Any operation performed by an operator is recorded automatically by the system. Thus, the
operation maintenance personnel can query historical operation records in some special
cases (such as abnormal system operations).
Security Management
Security management is implemented through user management and user group
management. The user element includes the user name and password, as well as which
user groups the user belongs to. The user group element includes the user group name
and authority information.
Performance Management
Performance management is to measure, report and make statistics of the System
performances.
-
8/11/2019 GB_SS43_E1_1 ZXSDR BTS Structure and Principle 67
65/65