![Page 1: Gary Ihas Interplay of Non-Quantum And Quantum Turbulence-Probes](https://reader030.vdocuments.mx/reader030/viewer/2022032803/56649e245503460f94b12eaf/html5/thumbnails/1.jpg)
Gary Ihas
Interplay of Non-QuantumAnd
Quantum Turbulence-Probes
![Page 2: Gary Ihas Interplay of Non-Quantum And Quantum Turbulence-Probes](https://reader030.vdocuments.mx/reader030/viewer/2022032803/56649e245503460f94b12eaf/html5/thumbnails/2.jpg)
• Controlled temperature environment-regulated heat flows
• Low Heat Capacities-Sensitive energy measurements
• Size-can be much smaller
• New materials and properties-e.g. superconductivity
• New techniques—e.g. NMR
Good and Bad of Low TemperaturesGood
Bad
•Difficulty of refrigeration
•Room temperature sensors don’t work or need modifications
•Size restrictions
![Page 3: Gary Ihas Interplay of Non-Quantum And Quantum Turbulence-Probes](https://reader030.vdocuments.mx/reader030/viewer/2022032803/56649e245503460f94b12eaf/html5/thumbnails/3.jpg)
A look at the 4He phase diagram
(r) = 0
(r)e iSv Ss
m4
4 4
hd
m msv l S n
vs 0
Superfluid is irrotational, but can have finite circulation about a line singularity (vortex core):
superfluidity breaks down due to production of quantized vortices
![Page 4: Gary Ihas Interplay of Non-Quantum And Quantum Turbulence-Probes](https://reader030.vdocuments.mx/reader030/viewer/2022032803/56649e245503460f94b12eaf/html5/thumbnails/4.jpg)
Two Fluid Model– Landau in 1941
[J. Wilks, 1987]
Viscosity (P)
4He
(oscillating disc viscometer)
56 %
Fluid density
0 2.0 T
T (K)
n
s
=n +s 0.14g/cm3
Sn=SHe = n nnormal fluid
Ss =0s =0
irrotational
sSuper-fluid
Two fluids
entropyviscositydensityTwo Fluid model
0 s
on)conservati (momentum 0
)(
on)conservati(entropy 0
on)conservati (mass 0
r
P
t
JtDt
D
st
st
ii
sssss
n
Two-fluid equations for He II:
total mass flow ssnnJ
jsissjninnijij pP ,,,, stress tensor
[S.J. Putterman, 1974]
![Page 5: Gary Ihas Interplay of Non-Quantum And Quantum Turbulence-Probes](https://reader030.vdocuments.mx/reader030/viewer/2022032803/56649e245503460f94b12eaf/html5/thumbnails/5.jpg)
Quantization of Superfluid Circulation
Quantization of superfluid circulation:
scmnm
nhds / 1097.9 24
(postulated separately in 1955 by Onsager and Feynman)
The angular velocity is
(a) 0.30 /s, (b) 0.30 /s,
(c) 0.40 /s, (d) 0.37 /s,
(e) 0.45 /s, (f) 0.47 /s,
(g) 0.47 /s, (h) 0.45 /s,
(i) 0.86 /s, (j) 0.55 /s,
(k) 0.58 /s, (l) 0.59 /s.
[Yarmchuk, 1979]
1. Circulation round any circular path of radius r concentric with the axis of rotation=2r2
2. Total circulation=r2n0h/m (n0: # of lines per unit area)
3. n0=2 m/h=2 /
All superfluid vortex lines align along the rotation axis with ordered array of areal density= length of quantized vortex line per unit volume=
2000 lines/cm2
s
2
![Page 6: Gary Ihas Interplay of Non-Quantum And Quantum Turbulence-Probes](https://reader030.vdocuments.mx/reader030/viewer/2022032803/56649e245503460f94b12eaf/html5/thumbnails/6.jpg)
Superfluids (4He; 3He-B; cold atoms) exhibit
• Two fluid behaviour: a viscous normal component + an “inviscid” superfluid component. Normal component disappears at lowest temps.
• Quantization of rotational motion in the superfluid component.
Quantization of rotational motion: , except on quantized vortex lines, each with one quantum of circulation
0svcurl
34 2mhmhds or rv
(Consequences of Bose or BCS condensation.)
Kinematic viscosity of normal fluid: 4He very small; 3He-B very large. Turbulence in normal fluid? 4He: YES; 3He-B: NO.
( ~0.05 nm for 4He; ~80nm for 3He-B; larger for Bose gases).
round a core of radius equal to the coherence length
Simple Superfluids Re-cap
![Page 7: Gary Ihas Interplay of Non-Quantum And Quantum Turbulence-Probes](https://reader030.vdocuments.mx/reader030/viewer/2022032803/56649e245503460f94b12eaf/html5/thumbnails/7.jpg)
Grid Turbulence
quantum of circulation:h/m4~10-3cm2 s-1 (n=1)
L = length of quantized vortex line per unit volume.
s= L = total rms superfluid vorticity
= L-1/2 = average inter-vortex line spacing.
H e II
Er
aveff
0
FHG
IKJ
s
2
4ln (~10-7erg cm-1, a0~0.1 nm, reff ~ )
![Page 8: Gary Ihas Interplay of Non-Quantum And Quantum Turbulence-Probes](https://reader030.vdocuments.mx/reader030/viewer/2022032803/56649e245503460f94b12eaf/html5/thumbnails/8.jpg)
Stalp Apparatus
![Page 9: Gary Ihas Interplay of Non-Quantum And Quantum Turbulence-Probes](https://reader030.vdocuments.mx/reader030/viewer/2022032803/56649e245503460f94b12eaf/html5/thumbnails/9.jpg)
Second Sound and NMR
Second sound, used successfully to measure vortex line density in 4He, does not propagate below 1 K in 4He or in superfluid 3He.
However, NMR signals can be used to measure vortex densities in 3He, with very high sensitivity.
Second Sound and NMR
![Page 10: Gary Ihas Interplay of Non-Quantum And Quantum Turbulence-Probes](https://reader030.vdocuments.mx/reader030/viewer/2022032803/56649e245503460f94b12eaf/html5/thumbnails/10.jpg)
Length scales: wide range of scales from the size of the flow obstacle or channel giving rise to the turbulence to the (small) scale on which dissipation occurs.
E.g. turbulence in 4He above 1K has energy-containing eddies of 1 cm and characteristic velocity 1 cm s-1. Below 1K Kelvin wave cascade (Vinen) to dissipate energy may take smallest scale to 10 nm.
Time scales: ranges from 1 s to a few milliseconds.
Velocity correlation functions: play an important role in classical turbulence (structure functions). We could derive energy spectra from them and look for deviations from Kolmogorov scaling (higher-order structure functions).
Do not underestimate the importance of visualizing the flow.
Need Probe of Vorticity-- requirements
![Page 11: Gary Ihas Interplay of Non-Quantum And Quantum Turbulence-Probes](https://reader030.vdocuments.mx/reader030/viewer/2022032803/56649e245503460f94b12eaf/html5/thumbnails/11.jpg)
We shall wish to discuss probes (other than PIV and LDV) that measure local properties (such as pressure, velocity). Remember that ideally we need a spatial resolution of at least 30 microns and a frequency response to at least 1 kHz.
Hot wire anemometers do not work in 4He owing to the high thermal conductivity. Could they work in 3He?
A pressure transducer with a spatial resolution of about 1 mm and good frequency response was used in an important experiment by Maurer and Tabeling. We are pursuing smaller pressure transducers based on nano-fabrication techniques.
We have made a nano-scale flow measuring device seems to not detect super flow!
Localized probes
![Page 12: Gary Ihas Interplay of Non-Quantum And Quantum Turbulence-Probes](https://reader030.vdocuments.mx/reader030/viewer/2022032803/56649e245503460f94b12eaf/html5/thumbnails/12.jpg)
Acoustic Probe in TSF
• Refrigerator-vibrations proof (tested in -situ)
• Operation checked at room temperature
• Should work both in HeI and HeII
for ref. : Baudet, Gagne (LEGI)
![Page 13: Gary Ihas Interplay of Non-Quantum And Quantum Turbulence-Probes](https://reader030.vdocuments.mx/reader030/viewer/2022032803/56649e245503460f94b12eaf/html5/thumbnails/13.jpg)
Hot wire for the TSF experiment
• Stripped Nb-Ti wire• velocity-dependent quenched length -> velocity dep. resistance • Focused ion beam machining
13 2 2
Tc
Température
T
for ref. : P. Diribarne PhD (Inst. Neel)
![Page 14: Gary Ihas Interplay of Non-Quantum And Quantum Turbulence-Probes](https://reader030.vdocuments.mx/reader030/viewer/2022032803/56649e245503460f94b12eaf/html5/thumbnails/14.jpg)
Hot wire anemometer (He-I) & 2nd sound probe (He-II)
• Hot wire
• 2nd sound open cavity
(next part of the talk)
![Page 15: Gary Ihas Interplay of Non-Quantum And Quantum Turbulence-Probes](https://reader030.vdocuments.mx/reader030/viewer/2022032803/56649e245503460f94b12eaf/html5/thumbnails/15.jpg)
80 g/s flow
• T = 1.6 K superfluid ratio = 84%
• V = 0.3-1.3 m/s Re = V./ up to 3.105
T. Didelot (ex. PhD)
He II
Conduite=2,5cm
Hélice
Axe
Mesures
Axis
propeller
local probes
pipe
Pitot tube(mean velocity)
Screens
Honeycomb2.3 cm
![Page 16: Gary Ihas Interplay of Non-Quantum And Quantum Turbulence-Probes](https://reader030.vdocuments.mx/reader030/viewer/2022032803/56649e245503460f94b12eaf/html5/thumbnails/16.jpg)
Assembly of the 2nd sound sensor
• Cavity size :1mm*1mm*250m
Thickness ~ 15m
Gap ~ 250m
QuickTime™ et undécompresseur TIFF (LZW)
sont requis pour visionner cette image.
Design/micromachining of both beams :H. Willaime, P. Tabeling, Microfluidic group, ESPCIO. Français, L. Rousseau, Micromachining center, ESIEE
![Page 17: Gary Ihas Interplay of Non-Quantum And Quantum Turbulence-Probes](https://reader030.vdocuments.mx/reader030/viewer/2022032803/56649e245503460f94b12eaf/html5/thumbnails/17.jpg)
![Page 18: Gary Ihas Interplay of Non-Quantum And Quantum Turbulence-Probes](https://reader030.vdocuments.mx/reader030/viewer/2022032803/56649e245503460f94b12eaf/html5/thumbnails/18.jpg)
Thermistor Characteristics
Operating temperature: 10 – 100 mK
Sensitivity: T ~ 10-4 mK
Short response time: ~ 1 ms
Small mass & good thermal contact.
Ease of manufacture
Calorimetry Probe Development
![Page 19: Gary Ihas Interplay of Non-Quantum And Quantum Turbulence-Probes](https://reader030.vdocuments.mx/reader030/viewer/2022032803/56649e245503460f94b12eaf/html5/thumbnails/19.jpg)
Sensor Package Construction Ge/GaAs thermistors 300 m square by 150 m thick.
1 and 5: copper discs; 2: gold strip; 3: corundum cylinder; 4: Ge/GaAs sensitive element; 6: copper wire; 7- tin.
Ge/GaAs Thin Film Element
Use computer chip fabrication technique: V. Mitin
http://microsensor.com.ua/products.html
![Page 20: Gary Ihas Interplay of Non-Quantum And Quantum Turbulence-Probes](https://reader030.vdocuments.mx/reader030/viewer/2022032803/56649e245503460f94b12eaf/html5/thumbnails/20.jpg)
Mass Production/Consistency Each wafer will generate sensors with very similar properties Resistance measurements made on a single batch over the range 10K – 150K A single fixed point measurement at 4.2K will approximate the sensors properties if the entire curve for any one sensor from the batch is known
1 10 10010
1
102
103
104
Re
sis
tan
ce,
Oh
ms
Tem p erature, K
Advantages of Thin Film Technology
![Page 21: Gary Ihas Interplay of Non-Quantum And Quantum Turbulence-Probes](https://reader030.vdocuments.mx/reader030/viewer/2022032803/56649e245503460f94b12eaf/html5/thumbnails/21.jpg)
Conduction in a doped semiconductor
1 10 10010
100
1000
10000
100000
1000000
Electron Collisions
(R~T-1)
Phonon Collisions
(R~T-1/2}
Variable Range Hopping
(R~exp{T-1/4})
Coulomb Interaction
(R~exp{T-1/2})
Re
sist
an
ce ()
Temperature (K)
![Page 22: Gary Ihas Interplay of Non-Quantum And Quantum Turbulence-Probes](https://reader030.vdocuments.mx/reader030/viewer/2022032803/56649e245503460f94b12eaf/html5/thumbnails/22.jpg)
Thermistor R vs. T Development WorkTune characteristics by heat treatment
25 50 75 100
10
100
1000
#2
#3 #1
R(k)
T (mK)
![Page 23: Gary Ihas Interplay of Non-Quantum And Quantum Turbulence-Probes](https://reader030.vdocuments.mx/reader030/viewer/2022032803/56649e245503460f94b12eaf/html5/thumbnails/23.jpg)
Pressure Transducer Requirements
sampling on micron scale sensitivity: 0.1 Pascal fast: 1 msec function at low temperatures (20 – 100 mK) transduction: as simple as possible
MEMS Technology Pressure Sensors Piezo-resistive Capacitive Optical
Another Probe or two or three
![Page 24: Gary Ihas Interplay of Non-Quantum And Quantum Turbulence-Probes](https://reader030.vdocuments.mx/reader030/viewer/2022032803/56649e245503460f94b12eaf/html5/thumbnails/24.jpg)
MEMS Technology
blockkkkkk
Perfect size range
![Page 25: Gary Ihas Interplay of Non-Quantum And Quantum Turbulence-Probes](https://reader030.vdocuments.mx/reader030/viewer/2022032803/56649e245503460f94b12eaf/html5/thumbnails/25.jpg)
Design Of Piezo-resistive Pressure Sensors Typical design: 4 piezo-resistors in Wheatstone bridge on a diaphragm diaphragm deflects from applied pressure causing the deformation of the piezo-resistors mounted on the surface
Wheatstone bridge
![Page 26: Gary Ihas Interplay of Non-Quantum And Quantum Turbulence-Probes](https://reader030.vdocuments.mx/reader030/viewer/2022032803/56649e245503460f94b12eaf/html5/thumbnails/26.jpg)
Piezo-resistive Pressure Sensor SM5108
Manufactured by Silicon Microstructures, Inc.
Semiconductor resistors joined by aluminum conductors in bridge configuration
Resistors placed on diaphragmTwo strained parallel to ITwo strained perpendicular to I
![Page 27: Gary Ihas Interplay of Non-Quantum And Quantum Turbulence-Probes](https://reader030.vdocuments.mx/reader030/viewer/2022032803/56649e245503460f94b12eaf/html5/thumbnails/27.jpg)
Piezo-resistive Pressure Sensor SM5108
![Page 28: Gary Ihas Interplay of Non-Quantum And Quantum Turbulence-Probes](https://reader030.vdocuments.mx/reader030/viewer/2022032803/56649e245503460f94b12eaf/html5/thumbnails/28.jpg)
Drawbacks of Piezo-resistive Pressure Sensors-Results Relatively low sensitivity Large temperature dependence temperature compensation necessary
0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.40
5
10
15
20
25
30
35
40
45
50
55 300 K 91.2 K - 94.6 K 64.4 K - 66.0 K 49.8 K - 51.0 K 40.4 K - 43.5 K 29.9 K - 30.4 K 22.9 K - 26.0 K 26.2 K
Voltage vs Pressure for Piezoresistive Transducer at varying temperatures
Vo
ltag
e (
mV
)
Pressure (Bar)
![Page 29: Gary Ihas Interplay of Non-Quantum And Quantum Turbulence-Probes](https://reader030.vdocuments.mx/reader030/viewer/2022032803/56649e245503460f94b12eaf/html5/thumbnails/29.jpg)
Nanotube/Film Technology• Small• Strong• Conducting• But not too conducting• Elastic• Stick to some surfaces
Can be used forThermometersHeatersStrain gaugesCapacitor platesFlow metersTurbulence detectors
![Page 30: Gary Ihas Interplay of Non-Quantum And Quantum Turbulence-Probes](https://reader030.vdocuments.mx/reader030/viewer/2022032803/56649e245503460f94b12eaf/html5/thumbnails/30.jpg)
Nanotube film AFM Image
1 micron
![Page 31: Gary Ihas Interplay of Non-Quantum And Quantum Turbulence-Probes](https://reader030.vdocuments.mx/reader030/viewer/2022032803/56649e245503460f94b12eaf/html5/thumbnails/31.jpg)
Nanotube FilmR vs. T measurements
1 10 100100
200
300
400
500
600R
in O
hm
s
T in K
![Page 32: Gary Ihas Interplay of Non-Quantum And Quantum Turbulence-Probes](https://reader030.vdocuments.mx/reader030/viewer/2022032803/56649e245503460f94b12eaf/html5/thumbnails/32.jpg)
Nanotube Flow Meter
![Page 33: Gary Ihas Interplay of Non-Quantum And Quantum Turbulence-Probes](https://reader030.vdocuments.mx/reader030/viewer/2022032803/56649e245503460f94b12eaf/html5/thumbnails/33.jpg)
Helium liquid or gas flow
TinnedCopper
G10 (fiberglas)
4-terminal ResistanceMeasurement
Nanotube Film Flow Sensor Test
![Page 34: Gary Ihas Interplay of Non-Quantum And Quantum Turbulence-Probes](https://reader030.vdocuments.mx/reader030/viewer/2022032803/56649e245503460f94b12eaf/html5/thumbnails/34.jpg)
Nanotube film “rope” test jig
![Page 35: Gary Ihas Interplay of Non-Quantum And Quantum Turbulence-Probes](https://reader030.vdocuments.mx/reader030/viewer/2022032803/56649e245503460f94b12eaf/html5/thumbnails/35.jpg)
Nanotube Flow Meter
1 2 3 4 5 6
800
900
1000
1100
1200
1300
1400
0 Flow 10psi Flow 20psi Flow 30psi Flow 40psi Flow 50psi Flow
Resistance() vs. Temperature(K) for 1.0mm Nanotube at varying Flow Rates
Res
ista
nce()
Temperature(K)
![Page 36: Gary Ihas Interplay of Non-Quantum And Quantum Turbulence-Probes](https://reader030.vdocuments.mx/reader030/viewer/2022032803/56649e245503460f94b12eaf/html5/thumbnails/36.jpg)
Nanofilm CapacitiveFlow/Pressure Fluctuation Sensor
AFM of Nanofilm
Flow
![Page 37: Gary Ihas Interplay of Non-Quantum And Quantum Turbulence-Probes](https://reader030.vdocuments.mx/reader030/viewer/2022032803/56649e245503460f94b12eaf/html5/thumbnails/37.jpg)
Optically Transduced Pressure Sensorsmicrosensor structure that deforms under pressure
resulting in a change in an optical signal
![Page 38: Gary Ihas Interplay of Non-Quantum And Quantum Turbulence-Probes](https://reader030.vdocuments.mx/reader030/viewer/2022032803/56649e245503460f94b12eaf/html5/thumbnails/38.jpg)
Choice of particle: neutrally-buoyant --helium has a very low density
small < 1 m
bound to vortex line
Type of turbulence: Grid—Van Sciver got weird results with counterflow
Visualizing FlowRequirements of PIV in quantum turbulence at low T
A new candidate: triplet state He2 excimer molecules
lifetime of about 13 s -- radius 0.53 nm -- Production ~ 13000 per Mev. )(aHe 3
2u (McKinsey et al, PRL 95, 111101 (2005))
![Page 39: Gary Ihas Interplay of Non-Quantum And Quantum Turbulence-Probes](https://reader030.vdocuments.mx/reader030/viewer/2022032803/56649e245503460f94b12eaf/html5/thumbnails/39.jpg)
• Illuminate with crossed pulsed lasers at 910 nm and 1040 nm(modest power). Only molecules in crossed beams react
•OObserve decay of d3+u to b3g
with emission at 640 nm (lifetime 25 ns).
• The b3g returns to a3 +u by
non-radiative processes (may need to be accelerated by optical means)
• Process recycles.
• ~ 4x107 photons/s at 640 nm.
How does it work?
![Page 40: Gary Ihas Interplay of Non-Quantum And Quantum Turbulence-Probes](https://reader030.vdocuments.mx/reader030/viewer/2022032803/56649e245503460f94b12eaf/html5/thumbnails/40.jpg)
Probing quantum turbulence has pluses and minuses
Visualization possible
Possible to make almost micron-size probes
All depends on much preparatory word = stable budgets for period of years
Re-Cap
![Page 41: Gary Ihas Interplay of Non-Quantum And Quantum Turbulence-Probes](https://reader030.vdocuments.mx/reader030/viewer/2022032803/56649e245503460f94b12eaf/html5/thumbnails/41.jpg)
Sreenivasan Einstein
![Page 42: Gary Ihas Interplay of Non-Quantum And Quantum Turbulence-Probes](https://reader030.vdocuments.mx/reader030/viewer/2022032803/56649e245503460f94b12eaf/html5/thumbnails/42.jpg)
“Simple fluids are easier to drink than understand.” --A.C. Newell and V. E. Zakharov, Turbulence: A
Tentative Dictionary ( Plenum Press, NY 1994)
Some quotes on the study of turbulent fluids…
“Simple fluids are easier to understand if you drink.” --G. Ihas and J. Niemela, Tiny’s Bar, Santa Fe, NM 2003