Transcript

UP

DN

KR01050F NA CABINET, BREAD AND BATTER

00

DN

D

00

UP

UP

KR01050FNA

CABINET, B RE AD AND B ATTE R

00

3976 SF

RESIDENTIALSERVERY

953 SF

RESIDENTIALDINING

1641 SF

RESIDENTIALDINING

2611 SFRETAIL SERVERY

1278

2277

16

30

7

70

1638

6

16

16

16

24

GRAY AREA INDICATES EXISTINGCEILING TO BE REMOVED ANDREINSTALLED AS NEEDED FOR

MECHANICAL WORK

GRAY AREA INDICATES EXISTINGCEILING TO BE REMOVED ANDREINSTALLED AS NEEDED FOR

MECHANICAL WORK

GRAY AREA INDICATES EXISTINGCEILING TO BE REMOVED ANDREINSTALLED AS NEEDED FOR

MECHANICAL WORK

EXISTING TO REMAIN AREA OF ALTERATIONS

1616

6 6

665655 SF

RETAIL DINING

AREA FOR STUDENT ACTIVITIES TABLING

FIXED COUNTER STOOLS

HARDWOOD CAP STAINED

FABRICATOR TO PROVIDE SHOP DRAWINGS FOR APPROVALBY ARCHITECT PRIOR TO ANY FABRICATION.

PROVIDE MECHANICAL FASTENERS TO ENSURELATERAL STABILITY IN ALL DIRECTIONS.

BASE OF BOOTHS & BANQUETTES TO BEPLYWOOD w/ P-LAM. OUTSIDE CORNERSTO BE EASED HARDWOOD W/ P-LAM ORAPPROVED DETAIL TO PREVENTDELAMINATION.

ALL VERTICAL BRACING AND SUPPORT MEMBERS TO BEOF PLYWOOD CONSTRUCTION.

PROVIDE NECESSARY HARDWOOD OR PREMIUM GRADEPLYWOOD FOR LATERAL BRACING AS REQUIRED.

STAINLESS STEEL SUPPORT LEGFASTENED TO TABLE TOP &SECURELY TO THE FLOOR

BOOTH TO WITHSTAND VERTICAL OR HORIZONTAL OF250 POUNDS AT ANY POINT ALONG LENGTH

REFER TO FURNITURE SCHEDULE

VARIES

FABRICATOR TO PROVIDE SHOPDRAWINGS FOR APPROVAL BYARCHITECT PRIOR TO ANYFABRICATION.

PROVIDE MECHANICALFASTENERS TO ENSURE LATERALSTABILITY IN ALL DIRECTIONS.

BASE OF BOOTHS & BANQUETTES TO BEPLYWOOD WITH P-LAM. OUTSIDECORNERS TO BE EASED HARDWOOD w/P-LAM OR APPROVED DETAIL TOPREVENT DELAMINATION.

STAINLESS STEEL SUPPORT LEGFASTENED TO TABLE TOP &SECURELY TO THE FLOOR

BOOTH TO WITHSTAND VERTICAL OR HORIZONTAL OF250 POUNDS AT ANY POINT ALONG LENGTH

REFE

R TO

FU R

NITU

RE S

CH

EDU L

E

VA

RIES

REFER TO FURNITURE SCHEDULE

VARIES

FURNITURE NOTESSEATING COUNTS

1. UPHOLSTERED FURNITURE MUST MEET CAL 117STANDARDS FOR FLAME SPREAD.

2. FURNITURE INSTALLER TO WORK WITH CONTRACTORAND PROJECT MANAGER TO SET UP DELIVERY ANDINSTALL TO BE WITH IN THE CONSTRUCTION SCHEDULE.

3. INSTALLER TO REMOVE ALL CARDBOARD, PACKINGMATERIALS, AND OTHER RELATED DEBRIS FROMPROJECT SITE AND RECYCLE AS MUCH AS IS POSSIBLE.

4. PROVIDE FURNITURE GLIDES WHICH AREMECHANICALLY FASTENED TO CHAIR AND TABLE BASEBOTTOMS.

5. FURNITURE GLIDES MUST BE DURABLE ANDREPLACEABLE.

6. FURNITURE GLIDES MUST OF A MATERIAL THAT CAN BEUSED ON RESILIENT FLOORING.

7. PROVIDE A LABELED BOX OF 100 ADDITIONAL CHAIRGLIDES.

8. PROVIDE A LABELED BOX OF 20 ADDITIONAL TABLEBASE GLIDES.

DINING SEATS: 265 ACCESSIBLE: 5

GENERAL NOTES

BARRIER FREE

NEW JERSEY ADMINISTRATIVE CODETITLE 5. COMMUNITY AFFAIRSCHAPTER 23. UNIFORM CONSTRUCTION CODESUBCHAPTER 7. BARRIER FREE SUBCODEN.J.A.C. 5:23-7.11 (2015)

5:23-7.11 Requirements applicable to specific nonresidentialGroups and Group R-1

(A) Occupancies of Group A shall be accessible as follows:

1. Where services and facilities are provided in areas that arenot required to be accessible, the same services andfacilities shall be provided in an accessible area and shall beaccessible.

2. In dining areas of occupancies of Use Groups A-2 and A-3,the total floor area allotted for seating and tables shall beaccessible, except as follows:

i. Where fixed or built-in seats and tables are provided, atleast five percent, but not fewer than one, of the seats andtables shall be accessible. Where more than one accessibleseat and table is provided, they shall be dispersed.

ii. In buildings without elevators, an accessible route to araised or lowered dining area of less than 3,000 square feet isnot required provided that the raised or lowered dining areacontains less than 25 percent of the total dining area and thesame services are available on the accessible level.

3. Accessible spaces for wheelchairs shall be provided ineach assembly area in accordance with the following table.

Capacity of Seating4-2526-50

51-300301-500 over 500

Accessible Seating1246

6 PLUS 1 FOREACH100 OVER 500

REVISIONS

DESCRIPTION:

ISSUED:

SHEET

CONNOR ARCHITECTURE ACCEPTS NO RESPONSIBILITY FOR UNAUTHORIZEDREPRODUCTION OR UNAUTHORIZED USE OF THIS DOCUMENT.

DRAWINGS ARE FOR GENERAL PURPOSES ONLY. NO MEASUREMENTSSHALL BE SCALED OFF DRAWINGS. ALL MEASUREMENTS SHALL BE VERIFIED

IN FIELD.

ENGINEER:

DRAWN BY:CHECKED BY:

CONNORARCHITECTURE

1656 Massachusetts Ave.Lexington, MA 02420

Tel: 781-652-0114connorarchitecture.com

ARCHITECT:

49 Court StreetP.O. Box 1980

Binghamton, NY 13902Tel: 607-723-9421

mjinc.com

NJDCA ELECTRONIC SUBMITTAL STAMP:

No.16419R

MARK CONN

RO

S YTATE

OF NEW JERSE

TEGIS T ERED ARCHI T

EC

3/31

/201

5 4:

47:2

1 PM

A105

FLO

OR

PLA

N -

F UR N

ITUR E

3.31.2015

DCA SUBMISSION

RAM

AP O

CO

L LE G

E O

F N

E W J

E RS E

Y50

5 RA

MA

PO V

ALL

EY R

D.

MA

HWA

H, N

J 07

430

R CN

J N

o . 2

014-

3 7-0

1 C

PHA

SE 1

: ALT

ERA

TION

S

AGK.AGK.

1/8" = 1'-0"

FURNITURE PLAN1

FURNITURE NOT IN GENERALCONTRACT - FOR REFERENCE ONLY

1 1/2" = 1'-0"

TYPICAL DOUBLE BOOTH DETAIL2 1 1/2" = 1'-0"

TYPICAL SINGLE BOOTH DETAIL3

FURNITURE NOT IN GENERAL CONTRACT - DETAILS FOR REFERENCE ONLY

GJR
Polygon

Top Related