People: Drilling and Maintenance Crews Plant and Equipment: Different types of Fall Protection Equipments and Anchorage Points / Facilities at rig site above 6 feet (1.8 m).Purpose: To identify areas on rig site requiring usage of fall protection equipments and to utilize proper fall protection equipments and anchorage points.
LOCATIONAPPROXIMATE HEIGHTFALL PROTECTION EQUIPMENTS REQUIREDANCHORAGE POINT(S)PHOTO
Rig floor to crown80 ft 81 ft.1. Full body harness
2. Lanyard
3. Fall Arrestor (SRL 80 ft)
4. Lad-Safe System
5. Climb-Assist Sytem
1. Lad-Safe System (when climbing from rig floor to crown). 2. Fall Arrestor (SRL 80 ft) installed at the crown (when working at the crown).
3. Climb-Assist System
Rig Floor to monkey board40 ft. 45 ft.1. Full body harness
2. Lanyard
3. SRL
3. Lad-Safe System
4. Climb-Assist System
1. Lad-Safe System (when climbing from rig floor to monkeyboard). 2. SRL 80 ft) installed at the crown (when working at the monkey board).
3. Climb-Assist System
Substructure25 ft 26 ft1. Full body harness
2.Lanyard
3. SRL
1. Fall Arrestor / SRL
Derrick beam / mast using manriding40 ft. 45 ft.1. Full body harness
2. Lanyard
1. Manriding winch lifting point / swivel
Derrick beam / mast using the ladder40 ft. 45 ft.1. Full body harness
2. Lanyard
3. SRL
3. Lad-Safe System
4. Climb-Assist System
1. Lad-Safe System
2.Climb-Assist System
Fuel Tanks7 ft. 8 ft.1. Full body harness
2.Lanyard
3. SRL
1. Fall Arrestor / SRL
2. Tie-off AdapterRig Diesel Tank
Aramco Diesel Tank
Gasoline Tank
Roof of MCC Room7 ft. 8 ft.1. Full body harness
2.Lanyard
3. SRL
3. Fall Arrestor / SRL
4. Tie-off Adapter
Rig Carrier Beam20 ft. 26 ft.1. Full body harness
2.Lanyard
3. SRL
1. Fall Arrestor / SRL
2. Tie-off Adapter3. Snoklift Anchorage hook
Cable Grasshopper27 ft. 28 ft.1. Full body harness
2.Lanyard
3. SRL
4. Fall Arrestor / SRL
5. Tie-off Adapter6. Snoklift Anchorage hook
2010 Weatherford International, Inc.
This document is copyrighted and, whether patentable or non-patentable subject matter, embodies the proprietary and confidential information of Weatherford. Recipients agree it is loaned in confidence with the understanding that neither it nor the information in it will be reproduced, used or disclosed in whole or in part for any purpose except the limited purpose for which it is loaned. This document shall be returned to Weatherford upon demand.
.Form Number : 3-4-GL-GL-WDI-0005, Rev 0 2010 Weatherford International, Inc.
This document is copyrighted and, whether patentable or non-patentable subject matter, embodies the proprietary and confidential information of Weatherford. Recipients agree it is loaned in confidence with the understanding that neither it nor the information in it will be reproduced, used or disclosed in whole or in part for any purpose except the limited purpose for which it is loaned. This document shall be returned to Weatherford upon demand.