![Page 1: Electronic Diver Safety Log - eDSL By: Mirayma V. Rodríguez Roberto Rivera Carlos Rubert Microprocessor Interfacing (ICOM 5217) May 5, 2006](https://reader034.vdocuments.mx/reader034/viewer/2022050714/56649d215503460f949f5c6c/html5/thumbnails/1.jpg)
Electronic Diver Safety Electronic Diver Safety Log - eDSLLog - eDSL
By:By:Mirayma V. RodrMirayma V. Rodrííguezguez
Roberto RiveraRoberto RiveraCarlos RubertCarlos Rubert
Microprocessor Interfacing (ICOM 5217)Microprocessor Interfacing (ICOM 5217)May 5, 2006 May 5, 2006
![Page 2: Electronic Diver Safety Log - eDSL By: Mirayma V. Rodríguez Roberto Rivera Carlos Rubert Microprocessor Interfacing (ICOM 5217) May 5, 2006](https://reader034.vdocuments.mx/reader034/viewer/2022050714/56649d215503460f949f5c6c/html5/thumbnails/2.jpg)
OutlineOutline
• IntroductionIntroduction• Theoretical BackgroundTheoretical Background• Software DesignSoftware Design• Hardware DesignHardware Design• Achievements and LimitationsAchievements and Limitations• ConclusionsConclusions• Future WorkFuture Work• Q&A sessionQ&A session
![Page 3: Electronic Diver Safety Log - eDSL By: Mirayma V. Rodríguez Roberto Rivera Carlos Rubert Microprocessor Interfacing (ICOM 5217) May 5, 2006](https://reader034.vdocuments.mx/reader034/viewer/2022050714/56649d215503460f949f5c6c/html5/thumbnails/3.jpg)
IntroductionIntroduction
• What is eDSL?What is eDSL?– The Electronic Diver Safety Log is a device for The Electronic Diver Safety Log is a device for
planning and monitoring safety dives.planning and monitoring safety dives.– Use pressure lectures to calculate depth.Use pressure lectures to calculate depth.– Use traditional method of dive tablesUse traditional method of dive tables
![Page 4: Electronic Diver Safety Log - eDSL By: Mirayma V. Rodríguez Roberto Rivera Carlos Rubert Microprocessor Interfacing (ICOM 5217) May 5, 2006](https://reader034.vdocuments.mx/reader034/viewer/2022050714/56649d215503460f949f5c6c/html5/thumbnails/4.jpg)
IntroductionIntroduction
• Our MotivationOur Motivation– Provide a device to increase safety in recreational Provide a device to increase safety in recreational
divedive– Help divers to plan different dives in a safe way using Help divers to plan different dives in a safe way using
dive tables.dive tables.
• Project DescriptionProject Description– Use of a pressure sensor to calculate depthUse of a pressure sensor to calculate depth– Use dive tables to get time and depth limitsUse dive tables to get time and depth limits– Alert divers when time or depth limits are reachedAlert divers when time or depth limits are reached
![Page 5: Electronic Diver Safety Log - eDSL By: Mirayma V. Rodríguez Roberto Rivera Carlos Rubert Microprocessor Interfacing (ICOM 5217) May 5, 2006](https://reader034.vdocuments.mx/reader034/viewer/2022050714/56649d215503460f949f5c6c/html5/thumbnails/5.jpg)
Theoretical BackgroundTheoretical Background
• Underwater explorationUnderwater exploration– SCUBA DivingSCUBA Diving
• Self-Contained Underwater Breathing ApparatusSelf-Contained Underwater Breathing Apparatus
– Safe and secure diving experienceSafe and secure diving experience• Decompression SicknessDecompression Sickness
– Air MixturesAir Mixtures» Nitrogen and AirNitrogen and Air
– PressurePressure– Nitrogen in BodyNitrogen in Body
![Page 6: Electronic Diver Safety Log - eDSL By: Mirayma V. Rodríguez Roberto Rivera Carlos Rubert Microprocessor Interfacing (ICOM 5217) May 5, 2006](https://reader034.vdocuments.mx/reader034/viewer/2022050714/56649d215503460f949f5c6c/html5/thumbnails/6.jpg)
Dive TablesDive Tables
• Used for planning a safe and secure dive.Used for planning a safe and secure dive.• Developed by the US Navy and NOAADeveloped by the US Navy and NOAA• Depends on the air mixtureDepends on the air mixture• Dive TablesDive Tables
– Table OneTable One• Used to calculate the Nitrogen Level after spending time at a Used to calculate the Nitrogen Level after spending time at a
particular depth.particular depth.– Table TwoTable Two
• Used to calculate the Nitrogen Level after spending time on Used to calculate the Nitrogen Level after spending time on the surface prior to your second dive.the surface prior to your second dive.
– Table ThreeTable Three• Used to calculate the Residual Nitrogen Time after Used to calculate the Residual Nitrogen Time after
completing the surface interval.completing the surface interval.
![Page 7: Electronic Diver Safety Log - eDSL By: Mirayma V. Rodríguez Roberto Rivera Carlos Rubert Microprocessor Interfacing (ICOM 5217) May 5, 2006](https://reader034.vdocuments.mx/reader034/viewer/2022050714/56649d215503460f949f5c6c/html5/thumbnails/7.jpg)
Table # 1Table # 1• Used to calculate the Used to calculate the Nitrogen Level Nitrogen Level after spending after spending
time at a particular depthtime at a particular depth
![Page 8: Electronic Diver Safety Log - eDSL By: Mirayma V. Rodríguez Roberto Rivera Carlos Rubert Microprocessor Interfacing (ICOM 5217) May 5, 2006](https://reader034.vdocuments.mx/reader034/viewer/2022050714/56649d215503460f949f5c6c/html5/thumbnails/8.jpg)
Table # 2Table # 2• Used to calculate the Nitrogen Level after spending time Used to calculate the Nitrogen Level after spending time
on the surface prior to your second dive.on the surface prior to your second dive.
![Page 9: Electronic Diver Safety Log - eDSL By: Mirayma V. Rodríguez Roberto Rivera Carlos Rubert Microprocessor Interfacing (ICOM 5217) May 5, 2006](https://reader034.vdocuments.mx/reader034/viewer/2022050714/56649d215503460f949f5c6c/html5/thumbnails/9.jpg)
Table # 3Table # 3• Used to calculate the Residual Nitrogen Time after Used to calculate the Residual Nitrogen Time after
completing the surface interval.completing the surface interval.
![Page 10: Electronic Diver Safety Log - eDSL By: Mirayma V. Rodríguez Roberto Rivera Carlos Rubert Microprocessor Interfacing (ICOM 5217) May 5, 2006](https://reader034.vdocuments.mx/reader034/viewer/2022050714/56649d215503460f949f5c6c/html5/thumbnails/10.jpg)
Software DesignSoftware Design
• User InterfaceUser Interface– Enter information about divesEnter information about dives
• Water TypeWater Type– FreshFresh– SaltSalt
• Number of DivesNumber of Dives• Information about divesInformation about dives
– Starting Nitrogen LevelStarting Nitrogen Level– Desire Depth and MinutesDesire Depth and Minutes
![Page 11: Electronic Diver Safety Log - eDSL By: Mirayma V. Rodríguez Roberto Rivera Carlos Rubert Microprocessor Interfacing (ICOM 5217) May 5, 2006](https://reader034.vdocuments.mx/reader034/viewer/2022050714/56649d215503460f949f5c6c/html5/thumbnails/11.jpg)
Software DesignSoftware Design
• Software BasicsSoftware Basics– Use dive tables to acquire time and depth limitationsUse dive tables to acquire time and depth limitations– The pressure is use to calculate the depth using the formula:The pressure is use to calculate the depth using the formula:
• This formula is derive from:This formula is derive from:
– When time or depth limits is reach, the system will alert the When time or depth limits is reach, the system will alert the diver by vibratingdiver by vibrating
– InterruptsInterrupts• Seconds (Time)Seconds (Time)• ADC (Pressure Sensor)ADC (Pressure Sensor)• UARTUART
81.9*
)1000*2(*)1(*28.3)(density
PftDepth
)12(*81.9*12 DDdensityPP
![Page 12: Electronic Diver Safety Log - eDSL By: Mirayma V. Rodríguez Roberto Rivera Carlos Rubert Microprocessor Interfacing (ICOM 5217) May 5, 2006](https://reader034.vdocuments.mx/reader034/viewer/2022050714/56649d215503460f949f5c6c/html5/thumbnails/12.jpg)
Software DesignSoftware Design
• Software ConsiderationsSoftware Considerations– Arrays in code vs. Memory SpaceArrays in code vs. Memory Space
• Tables SizeTables Size– Depth RestrictionsDepth Restrictions– Time RestrictionsTime Restrictions
![Page 13: Electronic Diver Safety Log - eDSL By: Mirayma V. Rodríguez Roberto Rivera Carlos Rubert Microprocessor Interfacing (ICOM 5217) May 5, 2006](https://reader034.vdocuments.mx/reader034/viewer/2022050714/56649d215503460f949f5c6c/html5/thumbnails/13.jpg)
System Block DiagramSystem Block Diagram
![Page 14: Electronic Diver Safety Log - eDSL By: Mirayma V. Rodríguez Roberto Rivera Carlos Rubert Microprocessor Interfacing (ICOM 5217) May 5, 2006](https://reader034.vdocuments.mx/reader034/viewer/2022050714/56649d215503460f949f5c6c/html5/thumbnails/14.jpg)
Hardware ConsiderationHardware Consideration
• Low PowerLow Power
• Low CostLow Cost
• PortabilityPortability
• Different Power SourcesDifferent Power Sources
![Page 15: Electronic Diver Safety Log - eDSL By: Mirayma V. Rodríguez Roberto Rivera Carlos Rubert Microprocessor Interfacing (ICOM 5217) May 5, 2006](https://reader034.vdocuments.mx/reader034/viewer/2022050714/56649d215503460f949f5c6c/html5/thumbnails/15.jpg)
Hardware ConsiderationsHardware Considerations
Major Considerations for Underwater Major Considerations for Underwater OperationOperation
- Temperature- Temperature
- Pressure- Pressure
Safety ConsiderationSafety Consideration
- T- The implementation of a Battery Gas Gaugehe implementation of a Battery Gas Gauge
![Page 16: Electronic Diver Safety Log - eDSL By: Mirayma V. Rodríguez Roberto Rivera Carlos Rubert Microprocessor Interfacing (ICOM 5217) May 5, 2006](https://reader034.vdocuments.mx/reader034/viewer/2022050714/56649d215503460f949f5c6c/html5/thumbnails/16.jpg)
Achievements & LimitationsAchievements & Limitations
• Display of variations in current depth and Display of variations in current depth and time.time.
• Alert System triggered by time and depth Alert System triggered by time and depth limits.limits.
• Max depth: 99 feet (400kPa or 130 ft from Max depth: 99 feet (400kPa or 130 ft from sensor)sensor)
• Prototype size may be too big.Prototype size may be too big.
• Unsuccessful log data retrieval.Unsuccessful log data retrieval.
• Limited to three dives.Limited to three dives.
![Page 17: Electronic Diver Safety Log - eDSL By: Mirayma V. Rodríguez Roberto Rivera Carlos Rubert Microprocessor Interfacing (ICOM 5217) May 5, 2006](https://reader034.vdocuments.mx/reader034/viewer/2022050714/56649d215503460f949f5c6c/html5/thumbnails/17.jpg)
ConclusionsConclusions
• Full integration between system hardware Full integration between system hardware components and software.components and software.
• Functional sensor reading for depth.Functional sensor reading for depth.
• Increase in diving safety due to alert Increase in diving safety due to alert system.system.
![Page 18: Electronic Diver Safety Log - eDSL By: Mirayma V. Rodríguez Roberto Rivera Carlos Rubert Microprocessor Interfacing (ICOM 5217) May 5, 2006](https://reader034.vdocuments.mx/reader034/viewer/2022050714/56649d215503460f949f5c6c/html5/thumbnails/18.jpg)
Future WorkFuture Work
• Size & Power Consumption reduction.Size & Power Consumption reduction.
• Log RetrievalLog Retrieval
• External programming.External programming.
• Longer depth rangeLonger depth range
• Other types of sensing signals.Other types of sensing signals.
• Other type of displayOther type of display
![Page 19: Electronic Diver Safety Log - eDSL By: Mirayma V. Rodríguez Roberto Rivera Carlos Rubert Microprocessor Interfacing (ICOM 5217) May 5, 2006](https://reader034.vdocuments.mx/reader034/viewer/2022050714/56649d215503460f949f5c6c/html5/thumbnails/19.jpg)