Infrastrukturen til fremtidens løsninger
Arne KellerNordic Regional Technical Manager
![Page 2: Datacenter 2014: Commscope - Arne Keller](https://reader031.vdocuments.mx/reader031/viewer/2022020717/5481be59b4af9fb9018b47b1/html5/thumbnails/2.jpg)
2PRIVATE AND CONFIDENTIAL © 2011 CommScope, Inc
THE DATA CENTER IS A LIVING PART OF YOUR ORGANIZATION, DRIVEN BY THE CHANGING LANDSCAPE AND THE NEEDS OF YOUR STAKEHOLDERS.
Investmentpreservation
Sustainability
Agility
Efficiency
![Page 3: Datacenter 2014: Commscope - Arne Keller](https://reader031.vdocuments.mx/reader031/viewer/2022020717/5481be59b4af9fb9018b47b1/html5/thumbnails/3.jpg)
3PRIVATE AND CONFIDENTIAL © 2011 CommScope, Inc
Today’s Data Centre andEmerging Trends and Technologies
Big Data Virtualized Green
Cloud ConvergedDCIMSDN
EthernetFCoEInfiniband
iSCSi ........
![Page 4: Datacenter 2014: Commscope - Arne Keller](https://reader031.vdocuments.mx/reader031/viewer/2022020717/5481be59b4af9fb9018b47b1/html5/thumbnails/4.jpg)
4PRIVATE AND CONFIDENTIAL © 2011 CommScope, Inc
Cabling in Data Centres
![Page 5: Datacenter 2014: Commscope - Arne Keller](https://reader031.vdocuments.mx/reader031/viewer/2022020717/5481be59b4af9fb9018b47b1/html5/thumbnails/5.jpg)
5PRIVATE AND CONFIDENTIAL © 2011 CommScope, Inc
Datacenter Design
The future will be diferent from today
![Page 6: Datacenter 2014: Commscope - Arne Keller](https://reader031.vdocuments.mx/reader031/viewer/2022020717/5481be59b4af9fb9018b47b1/html5/thumbnails/6.jpg)
6PRIVATE AND CONFIDENTIAL © 2011 CommScope, Inc
Pre-Terminated Cabling in theData Centres – Why Successful?
• Typical pre-term copper install is eight times faster than field term
• Reduces deployment risk
• “Phase II” install much less disruptive
• Minimal packaging on site - GREEN
Installation time dramatically reduced
![Page 7: Datacenter 2014: Commscope - Arne Keller](https://reader031.vdocuments.mx/reader031/viewer/2022020717/5481be59b4af9fb9018b47b1/html5/thumbnails/7.jpg)
7PRIVATE AND CONFIDENTIAL © 2011 CommScope, Inc
InstaPATCH Quattro
• UTP Trunk Cables & Breakouts– CMR / CMP / LSZH– Ribbonized or Bundled– High Density MC Connector– MC-MC or MC-RJ45 options
• 4-Port Modular Cassettes– High Density MC connector
as rear interface• Modular Panels
– 24p 1U• Intelligent Ready & Enabled
– 48p 1U High Density
![Page 8: Datacenter 2014: Commscope - Arne Keller](https://reader031.vdocuments.mx/reader031/viewer/2022020717/5481be59b4af9fb9018b47b1/html5/thumbnails/8.jpg)
8PRIVATE AND CONFIDENTIAL © 2011 CommScope, Inc
• Supports ALL fiber applications• Simple, scalable architecture
– Guaranteed polarity (Tx Rx)
– Migrates easily from duplex to parallel
• Industry-best application support – Distance, flexibility, operating margin
– 40G/100G Ethernet & 16G FC to 170m
• Highest Density in the industry• Elegant 360 design / Intelligence-Ready
LANSwitch
40G/100G
InstaPATCH 360 – Path to 100Gig
![Page 9: Datacenter 2014: Commscope - Arne Keller](https://reader031.vdocuments.mx/reader031/viewer/2022020717/5481be59b4af9fb9018b47b1/html5/thumbnails/9.jpg)
9PRIVATE AND CONFIDENTIAL © 2011 CommScope, Inc
40G/100G Ethernet:Current Fibre PMDs
40GbEPMDs
40GBASE-SR44 Lanes @ 850 nm100 m with OM3150 m with OM4
40GBASE-LR44 CWDM @ ~1310 nm 10 km with OS1/OS2
40GBASE-FR 40G @ ~1550 nm 2 km with OS1/OS2
100GbEPMDs
100GBASE-SR10
100GBASE-LR44 WDM @ ~1310 nm 10 km with OS1/OS2
100GBASE-ER4 4 WDM @ ~1310 nm 40 km with OS1/OS2
10 Lanes @ 850 nm100 m with OM3150 m with OM4
![Page 10: Datacenter 2014: Commscope - Arne Keller](https://reader031.vdocuments.mx/reader031/viewer/2022020717/5481be59b4af9fb9018b47b1/html5/thumbnails/10.jpg)
10PRIVATE AND CONFIDENTIAL © 2011 CommScope, Inc
40/100G: Multimode or Singlemode?
Multimode module(40GBASE-SR4)
Singlemode module(40GBASE-LR4)
Density 16 ports/ card 3-4 ports/ card
Power (40G) ~1.5W/ port ~8W/ port
Cost x 11x
Distance* 150m (OM4) > 150m
![Page 11: Datacenter 2014: Commscope - Arne Keller](https://reader031.vdocuments.mx/reader031/viewer/2022020717/5481be59b4af9fb9018b47b1/html5/thumbnails/11.jpg)
11PRIVATE AND CONFIDENTIAL © 2011 CommScope, Inc
• Impact of moving from 1 to 10 Gigabit Ethernet for server uplinks
• Higher speed, lower latency links have direct impact on performance
Big Data Study
http://www.cisco.com/en/US/prod/collateral/switches/ps9441/ps9670/white_paper_c11-690561.pdf
Response Time
Big Data network performance1G versus 10GbE uplinks
25% Reduction
![Page 12: Datacenter 2014: Commscope - Arne Keller](https://reader031.vdocuments.mx/reader031/viewer/2022020717/5481be59b4af9fb9018b47b1/html5/thumbnails/12.jpg)
12PRIVATE AND CONFIDENTIAL © 2011 CommScope, Inc
• Next Gen. 100GE– 10G/lane 25G/lane– Reduces MM cabling to single row MPO (QSFP transceiver)
• Potential seamless upgrade from 40GE
– Alternative SM solution using parallel fibre seems likely (QSFP)• Projected to save at least 50% on transceiver costs
• 32G Fibre Channel (FC-PI-6)– Serial transmission
– At least 100m on OM4
• 128G (4x32G) Fibre Channel– Parallel transmission
Applications on the Horizon
![Page 13: Datacenter 2014: Commscope - Arne Keller](https://reader031.vdocuments.mx/reader031/viewer/2022020717/5481be59b4af9fb9018b47b1/html5/thumbnails/13.jpg)
13PRIVATE AND CONFIDENTIAL © 2011 CommScope, Inc
MM or SM on Cisco/HP equipment?
Prices from Prices from www.dustin.se (SEK) (SEK) 20102010 20112011 20122012 2013-10 2013-10
• 1GB GBIC Cisco Multimode 3295 2695 2099 1899• 1GB GBIC Cisco Singelmode 6195 5695 5999 5199
• 1GB SFP HP Multimode 3195 2895 1299• 1GB SFP HP Singelmode 5695 5195 3999
• 10GB SFP Cisco Multimode --- 7995 8699 5099• 10GB SFP Cisco Singelmode --- 20995 21499 19999
• 10GB SFP+ HP Multimode 11995 11995 5499• 10GB SFP+ HP Singelmode 24495 22495 12999
In 2011, 1Gb multimode interface was 48% less than singlemodeIn 2013 , 1Gb multimode interface was 65% less than singlemode
In 2011, 10Gb multimode interface was 54% less than singlemodeIn 2013, 10Gb multimode interface was 77% less than singlemode
![Page 14: Datacenter 2014: Commscope - Arne Keller](https://reader031.vdocuments.mx/reader031/viewer/2022020717/5481be59b4af9fb9018b47b1/html5/thumbnails/14.jpg)
14PRIVATE AND CONFIDENTIAL © 2011 CommScope, Inc
MM or SM on Cisco/HP equipment?
Prices from www.dustin.se (SEK)Prices from www.dustin.se (SEK) 20102010 20112011 20122012 2013-10 2013-10
• 1GB GBIC Cisco Multimode 3295 2695 2099 1899• 1GB GBIC Cisco Singelmode 6195 5695 5999 5199
• 1GB SFP HP Multimode 3195 2895 1299• 1GB SFP HP Singelmode 5695 5195 3999
• 10GB SFP Cisco Multimode --- 7995 8699 5099• 10GB SFP Cisco Singelmode --- 20995 21499 19999
• 10GB SFP+ HP Multimode 11995 11995 5499• 10GB SFP+ HP Singelmode 24495 22495 12999
40G Ethernet multimode interface is 10 000 USD (listprice) less than singlemode100G Ethernet multimode interface is 80 000 USD (listprce) less than singlemode
![Page 15: Datacenter 2014: Commscope - Arne Keller](https://reader031.vdocuments.mx/reader031/viewer/2022020717/5481be59b4af9fb9018b47b1/html5/thumbnails/15.jpg)
15PRIVATE AND CONFIDENTIAL © 2011 CommScope, Inc
CommScope Data Center on DemandTruly Modular Data Center
• Scalable - 1, 4, 10, 20 Rack Configurations– Expandable while powered
• Rapid Deployment• Highly Efficient Evaporative Cooling System
– Low Maintenance / Green
– Wide Range of Operating Environments• High / Low Temperature & Humidity
– Real PUE - 1.01 to 1.06
• Customizable Upon Order– Tier II, Tier III, Mixed, Custom, w
– kW/Rack ranges - <10, 10-20, & 20-35 kW
– Input Voltages (200-240v or 380-415v)
– Optional Vestibules
– Security, Fire, PDUs, UPS, Generator, Transformers
– Optional Integrated DX or Chilled Water Coils
![Page 16: Datacenter 2014: Commscope - Arne Keller](https://reader031.vdocuments.mx/reader031/viewer/2022020717/5481be59b4af9fb9018b47b1/html5/thumbnails/16.jpg)
16PRIVATE AND CONFIDENTIAL © 2011 CommScope, Inc
CommScope DCU-04Expandability – Seamless Hot/Cold Aisles
![Page 17: Datacenter 2014: Commscope - Arne Keller](https://reader031.vdocuments.mx/reader031/viewer/2022020717/5481be59b4af9fb9018b47b1/html5/thumbnails/17.jpg)
17PRIVATE AND CONFIDENTIAL © 2011 CommScope, Inc
DCoD InteriorFamiliar & Manageable
LargeCold Aisle
LargeHot Aisle
NetworkCabling
Large Vestibule
Standard Vestibule
![Page 18: Datacenter 2014: Commscope - Arne Keller](https://reader031.vdocuments.mx/reader031/viewer/2022020717/5481be59b4af9fb9018b47b1/html5/thumbnails/18.jpg)
18PRIVATE AND CONFIDENTIAL © 2011 CommScope, Inc
Introducing SYSTIMAX imVision
![Page 19: Datacenter 2014: Commscope - Arne Keller](https://reader031.vdocuments.mx/reader031/viewer/2022020717/5481be59b4af9fb9018b47b1/html5/thumbnails/19.jpg)
19PRIVATE AND CONFIDENTIAL © 2011 CommScope, Inc
What challenges might you be facing?
• I have to document infrastructure records manually, this is very time consuming.
• Even simple changes to my network take a long time to plan and complete.
• Sometimes, planned changes cause unplanned problems.
• It is sometimes hard to recover from issues quickly.
• I am always Reacting to the unexpected.
• I have to audit my network several times during a year, changes may not be done during this time.
• There are a growing number of networked devices on my infrastructure, it is hard to keep track of them all.
• I find myself buying infrastructure capacity as this is easier and faster than checking what I have already.
• My team manages many remote sites, this is a challenge to do effectively.
My Network is becoming very difficult to manage…
![Page 20: Datacenter 2014: Commscope - Arne Keller](https://reader031.vdocuments.mx/reader031/viewer/2022020717/5481be59b4af9fb9018b47b1/html5/thumbnails/20.jpg)
20PRIVATE AND CONFIDENTIAL © 2011 CommScope, Inc
imVision a Web-based live documentation
BrowserBrowser
Html/httpHtml/http
Database Server (MS-SQL)Database Server (MS-SQL)
Application ServerApplication Server
Windows ServicesWindows ServicesWeb Server (IIS)Web Server (IIS)
Web ServicesWeb ServicesSOAP/AJAX/JSONSOAP/AJAX/JSON
![Page 21: Datacenter 2014: Commscope - Arne Keller](https://reader031.vdocuments.mx/reader031/viewer/2022020717/5481be59b4af9fb9018b47b1/html5/thumbnails/21.jpg)
21PRIVATE AND CONFIDENTIAL © 2011 CommScope, Inc
• Optimizing the Business Output of IT
– Performance
– Agility
– Availability
• Capacity Planning
– Making every square foot count
• Containing Costs
– OPEX (reduce)
– CAPEX (avoid or postpone)
DCIM:A dynamic game-changer
![Page 22: Datacenter 2014: Commscope - Arne Keller](https://reader031.vdocuments.mx/reader031/viewer/2022020717/5481be59b4af9fb9018b47b1/html5/thumbnails/22.jpg)
22PRIVATE AND CONFIDENTIAL © 2011 CommScope, Inc
• See, identify, and resolve issues across silos:
– Assets
– Power
– Connectivity
– Space
– Cooling, etc.
• Manage assets and their inter-dependencies
• Bridge IT, Facilities, Business, Finance, and Real Estate
DCIM objectives:Holistic insight into the physical ecosystem
![Page 23: Datacenter 2014: Commscope - Arne Keller](https://reader031.vdocuments.mx/reader031/viewer/2022020717/5481be59b4af9fb9018b47b1/html5/thumbnails/23.jpg)
23PRIVATE AND CONFIDENTIAL © 2011 CommScope, Inc
Ubiquitous In Building Wireless Service
ION
Wireless Capacity
Data Center Management
Increase Efficiency
and Reduce Complexity
iTRACS
Infrastructure Management
Improve Availability & Reduce
Complexity
imVisioniTRACS
Modular Data Center
Increase Scalability &
Reduce Investment
DCoD
Optimize Energy &
Space Efficiency
Redwood imVision
Energy & Space
Reliable Backup
Power for Business Continuity
Fuel Cells
Power
Services
Trusted Advisor Added
Value
Services
Comprehensive Portfolio of DATA CENTER Solutions
Data Transmission
Structured Cabling
SYSTIMAXUniprise
CommScope Data Center Solutions
![Page 24: Datacenter 2014: Commscope - Arne Keller](https://reader031.vdocuments.mx/reader031/viewer/2022020717/5481be59b4af9fb9018b47b1/html5/thumbnails/24.jpg)
24PRIVATE AND CONFIDENTIAL © 2011 CommScope, Inc
Thank You