Download - CONSTRUCTION LEGEND
SYMBOL DESCRIPTION DETAIL
4" THICK ENHANCED CONCRETE PAVING NUMBER 1. /COLOR AND FINISH TO BE SELECTED BY THE CITY.
4" THICK ENHANCED PEDESTRIAN CONCRETE PAVING /NUMBER 2. COLOR AND FINISH TO BE SELECTED BYTHE CITY.
4" THICK PEDESTRIAN PAVING. COLOR: NATURAL /GRAY. FINISH: MEDIUM BROOM.
EXISTING PEDESTRIAN PAVING TO REMAIN, PROTECT IN PLACE, TYP.
NEW ASPHALT PAVING PER CIVIL PLANS.
16" RAISED PLANTER WITH PRECAST CONCRETE CAP /AND STUCCO FINISH TO MATCH THE BUILDING. CAPMODEL #: CLASSIC WALL CAP BY STEPSTONE INC.SIZE 8". COLOR: TO BE SELECTED BY THE CITY.FINISH: SMOOTH.
TRASH AND RECYCLING RECEPTACLES. MODEL: POE. MANUFACTURER: LANDSCAPE FORMS. COLOR:BRONZE. PHONE NUMBER: (800) 430-6209.
BALLOT BOX, PER ARCHITECT.
LIBRARY DROP-OFF BOX, PER ARCHITECT.
EXISTING FLAG POLE, RELOCATED. 3/LC-2.0
BICYCLE RACKS MANUFACTURER: FORMS + 1/LC-2.0SURFACES. MODEL: `CAPITOL` SKCAP. COLOR: DARKBRONZE TO MATCH EXISTING HANDRAILS. PHONENUMBER: 800-451-0410.
PEDESTRIAN LIGHTING FIXTURES, TYP. SEE ELECTRICAL PLANS.
NEW ACCESSIBLE CURB RAMP WITH TRUNCATED DOMES, PER CIVIL PLANS.
NEW ACCESSIBLE PARKING SPACES, PER CIVIL PLANS.
UPLIGHTS PER ELECTRICAL PLAN.
NEW ACCESSIBLE PARKING SIGNAGE PER ARCHITECT AND CIVIL PLANS.
EXISTING TREE TO REMAIN, PROTECT IN PLACE, TYP.
ELECTRICAL AND IRRIGATION UTILITY STUBOUTS IN ROUND PLASTIC VALVE BOXES FOR FUTURE USE.
EXISTING BOLLARDS TO REMAIN, PROTECT IN PLACE.
STORMWATER TREATMENT UNIT PER CIVIL PLANS.
MAILBOX SUITE MODEL: SP-4C14S-12-P 2/LC-2.0MANUFACTURER: FLORENCE CORPORATION. COLOR:DARK BRONZE. PHONE NUMBER: 800-275-1747.
EXISTING ADA RAMP AND HANDRAILS, PROTECT IN PLACE. SEE ARCHITECTURAL AND CIVIL PLANS FORLOCATIONS OF TRANSITIONS FROM EXISTING TO NEWIMPROVEMENTS.
MONUMENTAL STAIRS AND HANDRAILS, PER ARCHITECT PLANS. COLOR: ENHANCED CONCRETECOLOR 2.
EXISTING UTILITY ENCLOSURE TO REMAIN, PROTECT IN PLACE.
INTERMEDIATE MASONRY WALL. REMOVE EXISTING CAP BLOCK AND PROTECT MASONRY UNITS IN PLACE.CONTRACTOR TO REPAIR MASONRY WALL ASNECESSARY. INSTALL NEW PRECAST CONCRETE CAPBLOCK AND APPLY STUCCO TREATMENT TO EXISTINGWALL TO MATCH BUILDING. SEE ALSO CONSTRUCTIONNOTE 24.
EXISTING IRRIGATION CONTROLLER TO REMAIN, PROTECT IN PLACE.
CONTRACTOR TO REPAIR EXISTING MASONRY WALL /AS NECESSARY. INSTALL NEW PRECAST CONCRETECAP AND STUCCO TREATMENT TO MATCH THEBUILDING. SEE ALSO CONSTRUCTION NOTE 24.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
CONSTRUCTION LEGEND:
4/LC-2.0
4/LC-2.0
4/LC-2.0
5/LC-2.0
1/LC-2.1
4/LC-2.1
BUILDING. SEE ALSO CONSTRUCTION NOTE 24.
LANDSCAPE AREA AT STORMWATER TREATMENT UNIT. SEE CIVIL AND PLANTING PLANS.
EXISTING PLANTING TO REMAIN, PROTECT IN PLACE.
6" RAISED MONOLITHIC CONCRETE CURB, NATURAL 6/LC-2.0GRAY, WITH SMOOTH TROWEL FINISH.
STORM WATER INLET, SEE CIVIL PLANS.
CONCRETE GUTTER IMPROVEMENTS, PER CIVIL PLANS.
EXISTING IRRIGATION MAINLINE, PROTECT IN PLACE.
CONCRETE GUTTER IMPROVEMENTS, PER CIVIL PLANS.
NEW ADA RAMP AND HANDRAILS, PER PLANS. SEE ARCHITECTURAL AND CIVIL PLANS FOR LOCATIONSOF TRANSITIONS FROM EXISTING TO NEWIMPROVEMENTS.
36" HEIGHT RAISED CONCRETE PLANTER WITH PRECAST CONCRETE CAP AND STUCCO FINISH TOMATCH BUILDING. APPLY WATERPROOFING TOBUIDLING PER ARCHITECT.
TIE IN EXISTING WALL WITH NEW WALL. CONTRACTOR TO REMOVE ONE BLOCK EVERY OTHER COURSE ATEXISTING WALL AND TO CONNECT NEW WALL TOEXISTING IN A RUNNING BOND FORMAT FORSTRENGTH. FLUSH JOINT CONNECTION IS NOTACCEPTABLE. SEE ALSO CONSTRUCTION NOTE 24.
CONTRACTOR TO RETURN WALL AND CAP AS NECESSARY TO BUILDING TO COMPLETE EACHPLANTER AREA AT CHANGE OF WALL ELEVATION.
ABOVE GRADE UTILITY, SEE CIVIL PLANS.
FLUSH MOUNT ELECTRICAL FIXTURE ON WALKWAY.
NEW PARKING BLOCKS AND STRIPING PER CIVIL PLANS.
NEW CURB AND GUTTER, PER CIVIL PLANS.
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
obr
GARR
ICK
OLI
VER
C
HRIS
TOPH
ER B
ITTN
ER
AN
NEY
RO
SEN
THAL
-HAL
L
3817
Ray
Str
eet S
an D
iego
, Ca
9210
4e
in
fo@
obra
rchi
tect
ure.
com
w
obra
rchi
tect
ure.
com
t 6
19.5
64.7
586
f 6
19.5
68.3
636
OBRARCHITECTURE, INC. ALL RIGHTSRESERVED. THE ABOVE DRAWINGS, IDEAS,AND EMBODIED DESIGNS THEREIN ARE THEPROPERTY OF OBRARCHITECTURE, INC. ANDSHALL NOT BE COPIED, REPRODUCED,DISCLOSED TO OTHERS OR USED INCONNECTION WITH ANY WORK OTHER THANTHE SPECIFIED PROJECT FOR WHICH THEYHAVE BEEN PREPARED, IN WHOLE OR INPART, WITHOUT THE PRIOR WRITTENAUTHORIZATION OF OBRARCHITECTURE, INC.
Date Issued
Job No.
Sheet No.
CITY
HAL
L /
PUBL
IC L
IBRA
RY P
ROJE
CTCI
TY O
F LA
GUN
A W
OO
DS24
264
El T
oro
Rd, L
agun
a W
oods
, CA
9263
7
8.03.2021
CLW-006
DN BY: AS, BP CK BY: JJ, JT
08.30.2021PLT DATE:
SDG PRJ # 20-105
PERM
IT S
ET
REVISIONSNo.
LC-1.0
1. UNLESS SPECIFIED OTHERWISE, LANDSCAPE CONSTRUCTION AND LAYOUT WORK INCLUDES, BUT IS NOT LIMITED TO THELOCATION, PLACEMENT AND DETAILING OF THE PAVING TO OCCUR ADJACENT TO THE BUILDING, CONCRETE MASONRYWALLS, CONCRETE MASONRY SEAT WALLS, LANDSCAPE WALLS, CONSTRUCTION OF CERTAIN SPECIFIED SITE FURNITURE.
2. SEE ENGINEER'S PLAN FOR PARKING AREA, SITE DRAINAGE AND GRADING, FINISH GRADING, SITE UTILITY LAYOUT ANDCONSTRUCTION.
3. DIMENSIONS INDICATED ON PLANS SHALL PREVAIL OVER PLAN SCALE. DIMENSIONS ARE TO FACES OF ANDPERPENDICULAR FACE OF BUILDING WALLS UNLESS SHOWN OTHERWISE. ALL ANGLES AND CONNECTIONS ARE (90)DEGREES UNLESS NOTED OTHERWISE. WALKS CONNECTING DOORS ARE TO BE ALIGNED WITH FACE OF BUILDINGUNLESS NOTED OTHERWISE.
4. ALL COORDINATE POINTS AND DIMENSIONS ARE TAKEN FROM THE BACK OF CURB UNLESS OTHERWISE NOTED.
5. EXPANSION JOINTS SHALL BE AS LOCATED ON THE PLANS AND WHERE CONCRETE MEETS EXISTING WALLS, PAVING, OROTHER HARD SURFACES. EXPANSION JOINTS SHALL BE SEALED TO PREVENT MOISTURE SEEPAGE AFTER CURING.EXPANSION JOINTS ON WALKS TO BE A MAXIMUM OF 30'-0" ON CENTER. PROVIDE 1/2" SMOOTH DOWELS AT 24" O.C. AT ALLEXPANSION JOINTS AND #3 REBAR DOWELS AT 24" O.C. AT ALL CONSTRUCTION JOINTS. CONTRACTOR SHALL DRILLEXISTING CONCRETE TO REMAIN AND EPOXY SET AS REQUIRED. ALL EXPANSION JOINTS TO BE SANDED. COORDINATESAND COLOR WITH PAVEMENT COLOR.
6. SCORE JOINTS SHALL BE AS SHOWN ON THE PLANS OR SET ON TYPICAL ON CENTER SPACING AND ALIGN WITH BUILDINGEDGES.
7. CONSTRUCT EXPANSION, WEAKENED-PLANE (CONTRACTION) AND CONSTRUCTION JOINTS IN ACCORDANCE WITH SECTION303- 5.4 OF (GREENBOOK) STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION UNLESS OTHERWISE NOTED.
8. ALL CONCRETE SHALL BE A MINIMUM STRENGTH OF 2500 PSI AT 28 DAYS FOR PEDESTRIAN PAVING AND 4,000 PSI AT 28DAYS FOR VEHICULAR PAVING UNLESS OTHERWISE INDICATED. FINISH SHALL BE AS NOTED ON PLANS.
9. CONCRETE PAVING SHALL HAVE FINISHED GRADES SMOOTHED TO ELIMINATE PUDDLING OR STANDING WATER. ALLFINISH SURFACES SHALL MAINTAIN A 1.5% SLOPE AWAY FROM BUILDINGS AND WALLS INTO DRAINAGE STRUCTURES ANDSHALL HAVE A MAX. CROSS SLOPE OF 1.5%. CONTRACTOR SHALL NOTIFY THE CITY OF ANY CONFLICTS MAINTAININGDRAINAGE.
10. LAYOUT POINTS OF ALL RADIUS SHALL BE CONNECTED BY SMOOTH EVEN LINES TO CREATE THE CURVED CONFIGURATIONAS SHOWN ON THE PLANS.
11. SEE IRRIGATION PLANS FOR SLEEVE LOCATIONS PRIOR TO CONSTRUCTION.
12. SEE ELECTRICAL PLANS FOR CONDUIT AND LIGHT POLE LOCATIONS PRIOR TO CONSTRUCTION.
13. GRAFFITI PROTECTION: ALL VERTICAL MASONRY AND CONCRETE SURFACES, AND CONCRETE AMENITIES SUCH AS BUTNOT LIMITED TO TABLES, BENCHES, DRINKING FOUNTAINS, ETC. SHALL BE TREATED WITH A NON-SACRIFICIALANTI-GRAFFITI COATING. ANTI-GRAFFITI COATING SHALL BE AS MANUFACTURED BY PROSOCO OR APPROVED EQUAL.MATERIALS SHALL BE APPLIED PER MANUFACTURER'S SPECIFICATIONS AND RECOMMENDATIONS.
14. NO DEVIATIONS FROM PLANS SHALL OCCUR WITHOUT APPROVAL OF THE CITY.
15. CONTRACTOR SHALL VISIT SITE AND VERIFY ALL FIELD CONDITIONS PRIOR TO BEGINNING CONSTRUCTION.
16. CONTRACTOR SHALL REVIEW PLANS AND DETAILS TO ASCERTAIN LOCATIONS NECESSARY TO PROVIDE ELECTRICALCONNECTIONS TO POWER IRRIGATION, LIGHTING, ETC.
17. CONTRACTOR SHALL DETERMINE THE LOCATION AND DEPTH OF ALL SITE UTILITIES PRIOR TO CONSTRUCTION. NOTIFYTHE CITY OF ANY DISCREPANCIES IMMEDIATELY.
18. THE CONTRACTOR SHALL HAVE THE CITY VERIFY ALL CONSTRUCTION STAKING LOCATIONS PRIOR TO INSTALLATION OFCONCRETE PAVING.
19. ALL HARDWARE SUCH AS NAILS, BOLTS, FASTENERS ETC. SHALL BE HOT DIPPED GALVANIZED UNLESS OTHERWISE NOTED.
20. THE CONTRACTOR SHALL PROVIDE A 3'X3' MOCK UP OF ALL PAVING MATERIALS AND SEAT WALLS FOR APPROVAL BY THECITY, ARCHITECT, AND LANDSCAPE ARCHITECT PRIOR TO CONSTRUCTION.
21. ALIGN ALL UTILITY BOXES SET IN CONCRETE PARALLEL WITH ADJACENT SCORING.
22. ALL SIGNAGE TO BE PROTECTED IN PLACE UNLESS OTHERWISE NOTED ON THESE PLANS. CONTRACTOR IS RESPONSIBLETO COORDINATE WITH OWNERS REPRESENTATIVE FOR ANY SIGNS TO BE RELOCATED DUE TO CONSTRUCTION ACTIVITIES.
23. CONTRACTOR TO PROTECT ALL EXISTING UTILITIES IN PLACE, UNLESS OTHERWISE NOTED ON CIVIL AND ELECTRICALPLANS.
24. CONTRACTOR TO REMOVE EXISTING CAP BLOCK ON ALL EXISTING CMU WALLS AROUND CITY HALL BUILDING. REPAIRCONCRETE MASONRY BLOCK AS NECESSARY. SANDBLAST EXISTING WALL TO REMOVE ALL PAINT AND DEBRIS FROMEXISTING WALL. INSTALL NEW PRECAST CONCRETE CAP PER PLAN AND FINISH BOTH EXISTING NEW WALLS WITH A 3 PARTSTUCCO TREATMENT INCLUDING BROWN COAT, SKIM COAT AND COLOR/TEXTURE COAT. COLORS AND FINISHES TO BESELECTED BY THE CITY.
25. CONTRACTOR TO USE STANDARD 6" MASONRY BLOCKS SIZE TO MATCH EXISTING FOR STRAIGHT SECTIONS OF THEWALLS. CONTRACTOR SHALL PROVIDE POURED IN PLACE ENDS AT ALL PLANTERS WITH RADII.
26. CONTRACTOR IS RESPONSIBLE FOR RECONFIGURING AND RECONNECTING ALL EXISTING CITY HALL BUILDINGDOWNSPOUTS AND UTILITIES AS NECESSARY WHERE THE EXISTING CONDITIONS HAVE BEEN ALTERED BY THE NEW WALL
27. TYPICAL WALL CONSTRUCTION SHALL CONSIST OF CMU UNITS FOR STRAIGHT SECTIONS OF WALLS AND POURED IN PLACECONCRETE FOR RADIUS CORNERS.
CONSTRUCTION LEGEND CONT.:CONSTRUCTION NOTES:
FOR BIDDING PURPOSES ONLY: ENHANCED COLOR 1 TO BE OMAHA TAN WITH GRACE TOP-CAST #5 FINISH BY DAVIS COLORS.ENHANCED COLOR 2 TO BE SAN DIEGO BUFF WITH GRACE TOP-CAST #25 FINISH BY DAVIS COLORS. STUCCO PRODUCT SHALL BE BYOMEGA TO MATCH THE BUILDING.
CON
STRU
CTIO
N L
EGEN
D &
NO
TES
Date Issued 09.08.21
BID
SET
Date Issued 09.08.21Date Issued 09.08.21Date Issued 09.08.21
EL T
OR
O R
D.
WILLOW TREE CENTER ACCESS ROAD
UP
EXISTING CITYHALL BLDG.
PROPOSEDLIBRARY
BLDG.
obr
GARR
ICK
OLI
VER
C
HRIS
TOPH
ER B
ITTN
ER
AN
NEY
RO
SEN
THAL
-HAL
L
3817
Ray
Str
eet S
an D
iego
, Ca
9210
4e
in
fo@
obra
rchi
tect
ure.
com
w
obra
rchi
tect
ure.
com
t 6
19.5
64.7
586
f 6
19.5
68.3
636
OBRARCHITECTURE, INC. ALL RIGHTSRESERVED. THE ABOVE DRAWINGS, IDEAS,AND EMBODIED DESIGNS THEREIN ARE THEPROPERTY OF OBRARCHITECTURE, INC. ANDSHALL NOT BE COPIED, REPRODUCED,DISCLOSED TO OTHERS OR USED INCONNECTION WITH ANY WORK OTHER THANTHE SPECIFIED PROJECT FOR WHICH THEYHAVE BEEN PREPARED, IN WHOLE OR INPART, WITHOUT THE PRIOR WRITTENAUTHORIZATION OF OBRARCHITECTURE, INC.
Date Issued
Job No.
Sheet No.
CITY
HAL
L /
PUBL
IC L
IBRA
RY P
ROJE
CTCI
TY O
F LA
GUN
A W
OO
DS24
264
El T
oro
Rd, L
agun
a W
oods
, CA
9263
7
8.03.2021
CLW-006
DN BY: AS, BP CK BY: JJ, JT
08.30.2021PLT DATE:
SDG PRJ # 20-105
PERM
IT S
ET
REVISIONSNo.
12
3 7
8
9
10
11
17
19
20
21
24
26
25
23
16
22
13
14
16
28
29
15
17
4
14
LC-1.1
18
32
5TYP.
33
17
29
34
5
1. SEE SHEET LC-1.0 FOR CONSTRUCTION LEGEND AND NOTES2. SEE SHEETS LC-2.0 - LC-2.1 FOR CONSTRUCTION DETAILS
GENERAL NOTES:
5 10 20
1" = 10'-0"SCALE :
0
NORTH
25
35
36
37
36
36
6
30
6
27 27
27
17
17 37
29
12
38
38
39
40 4142
17
29
6
7
CON
STRU
CTIO
N P
LAN
18
Date Issued 09.08.21
BID
SET
Date Issued 09.08.21Date Issued 09.08.21Date Issued 09.08.21
obr
GARR
ICK
OLI
VER
C
HRIS
TOPH
ER B
ITTN
ER
AN
NEY
RO
SEN
THAL
-HAL
L
3817
Ray
Str
eet S
an D
iego
, Ca
9210
4e
in
fo@
obra
rchi
tect
ure.
com
w
obra
rchi
tect
ure.
com
t 6
19.5
64.7
586
f 6
19.5
68.3
636
OBRARCHITECTURE, INC. ALL RIGHTSRESERVED. THE ABOVE DRAWINGS, IDEAS,AND EMBODIED DESIGNS THEREIN ARE THEPROPERTY OF OBRARCHITECTURE, INC. ANDSHALL NOT BE COPIED, REPRODUCED,DISCLOSED TO OTHERS OR USED INCONNECTION WITH ANY WORK OTHER THANTHE SPECIFIED PROJECT FOR WHICH THEYHAVE BEEN PREPARED, IN WHOLE OR INPART, WITHOUT THE PRIOR WRITTENAUTHORIZATION OF OBRARCHITECTURE, INC.
Date Issued
Job No.
Sheet No.
CITY
HAL
L /
PUBL
IC L
IBRA
RY P
ROJE
CTCI
TY O
F LA
GUN
A W
OO
DS24
264
El T
oro
Rd, L
agun
a W
oods
, CA
9263
7
8.03.2021
CLW-006
DN BY: AS, BP CK BY: JJ, JT
08.30.2021PLT DATE:
SDG PRJ # 20-105
PERM
IT S
ET
REVISIONSNo.
LC-2.0
5'-7"
1'-6 1316"
12"
12"
4"
ELEVATION
PEDESTAL DETAIL
10"
NOTES:
1. AT LEAST ONE CUSTOMERCOMPARTMENT SHALL BEPOSITIONED LESS THAN 48 INCHESABOVE THE FINISHED FLOOR.
2. NO PARCEL LOCKERCOMPARTMENT (INTERIORBOTTOM SHELF) SHALL BEPOSITIONED LESS THAN 15 INCHESABOVE THE FINISHED FLOOR.
3. NO CUSTOMER LOCK SHALL BELOCATED MORE THAN 67 INCHESABOVE THE FINISHED FLOOR.
4. NO CUSTOMER COMPARTMENT(INTERIOR BOTTOM SHELF) SHALLBE POSITIONED LESS THAN 28INCHES ABOVE THE FINISHEDFLOOR.
5. THE USPS ARROW LOCK SHALL BELOCATED BETWEEN 36 AND 48INCHES ABOVE THE FINISHEDFLOOR.
1
2
3
4
5
MAILBOX SUITE
6
7
MIN 3.5"
12"
6"
4
7
8"
1
3
3
2
BASE ATTACHMENTENLARGEMENT
PEDESTAL1
BUTYL RUBBER PAD2
PEDESTAL PLATE3
MOUNTING NUT / WASHER4
FINISHED GRADE, PER PLAN5
CABINET PER PLAN6
1/2" DIA. BY 5 1/2" ANCHORBOLT
7
24"
2
8'-0"
30"
FLAG POLE PERCONSTRUCTION LEGEND.INSTALL PERMANUFACTURER'SRECOMMENDATION
1
2
3000 PSI CONCRETE FOOTINGPER MANUFACTURER'SRECOMMENDATION.
3
HARDWOOD WEDGES.(SUPPLIED BY CONTRACTOR)
4
10" DIA. 16 GA. CORRUGATEDGALV. STEEL GROUND SLEEVEFILLED W/ DRY SAND TIGHTLYTAMPED AFTER ALIGNINGPOLE.
5
(8) #4 VERT. BARS EVENLYSPACED
6
1
3
5
6
2
ALUMINUM FLASH COLLAR
7" DIA
3" MINTYP.
6", 14 GAUGE SPUN ALUMINUMBALL
74
LEGEND
5'-0"CLEARHEIGHT
8
9" CAST ALUMINUM CLEATWITH LOCKING CLEAT COVER
8
EXPOSEDHEIGHT:
30'-0"
6'-0"
FLAG POLE FOOTING
SINGLE SHEAVE TRUCK, CASTALUMINUM REVOLVING,NON-FOULING TYPE WITHSTAINLESS STEEL BALLBEARINGS
9
9
7
CL
SLOPE 1% MIN AWAY FROMPOST
10
10
38" GALV. STEEL BEARING PLATE11
11
12
34" STEEL GROUND SPIKE AND 38"GALV. SUPPORT PLATE
126" CLR.
#3 CIRCULAR TIES W/ 90 DEGSTD. HK EA. END @ 12" O.C.
13
13
#3 TIES @3" O.C.
3" CLR.
ENHANCED CONCRETE PERPLANS
14
13
3
38-3/4"
4"
18"1
2
3
4
56 22"
7
8
STEEL SLAT TRASH RECEPTACLE
ELEVATION BASE CASTINGPLAN VIEW
9
CONCRETE FOOTING1
6" THREADED J-BOLT ANCHORBOLTS
2
12 GAUGE SLOTTED STEEL3
TRASH RECEPTACLE PER PLANS4
ADJACENT PAVING PER PLANS5
FINISHED GRADE6
7/16" HOLE FOR SURFACE MOUNT7
13/16" DRAIN HOLE8
COMPACTED SUBGRADE TO 90%RELATIVE COMPACTION. TYP.
9
12"
5 6" RAISED MONOLITHIC CONCRETE CURB
1
2
3 4
5
6 7 8
1"
3"6"
1/2" RADIUS ON ALL EDGES1
NATURAL GRAY CONCRETE PAVING2
NATURAL GRAY 6" RAISED CURBMONOLITHIC WITH CONCRETEPAVING
3
3" MULCH LAYER4
TOPSOIL5
#4 REBAR HORIZONTAL ANDCONTINUOUS OVERLAP SPLICES 12"MINIMUM
6
COMPACTED SUBGRADE7
#3 BARS @ 18" OC BOTH WAYS8
6"
6
NOTES:1. CONTRACTOR SHALL COORDINATE WITHMANUFACTURER FOR DELIVERY OF BICYCLERACK, AND SHALL INSTALL PERMANUFACTURER'S RECOMMENDATIONS.
2. FOOTING SHALL MEET ADJACENT PAVINGFLUSH, TYPICAL.
1
2
4
5
2'-10"
5"
3" MIN.
1.6"
1"
6
6
ELEVATION
BASECONNECTION
PLAN
BICYCLE RACK WITH EMBEDMENT
3
38-3/4"
1'
COMPACTED SUBGRADE TO90% RELATIVE COMPACTION,TYP.
1
BIKE RACK PER PLANS2
CONCRETE FOOTING PERMANUFACTURER'SRECOMMENDATION FOREMBEDMENT
3
ADJACENT PAVING PERPLANS
4
FINISHED GRADE PER CIVILPLANS
5
MOUNTING ANCHORS PERMANUFACTURER'SRECOMMENDATIONS
6
1
4
(SEE PLAN)
5
7
6 WIDTH VARIES 65
SEECHART
2
1 7
3
BASE MATERIAL - PER CHART.
REBAR - SEE CHART FOR SIZE
A. AT A MINIMUM PROVIDE THE FOLLOWING:CONSTRUCTION JOINTS: 10' O.C.EXPANSION JOINTS: 30' O.C.
NOTES:
COMPACTED SUBGRADE TO 90% MINIMUMRELATIVE COMPACTION
432
1LEGEND:
FINISH GRADE 1" BELOW EDGE OF PAVINGIN TURF AREAS TO HAVE SOD, 1/2" INAREAS TO BE HYDROSEEDED, 2" IN SHRUBBEDS.
1/2 RAD. ON ALL OUTSIDE EDGES.CONCRETE PAVING - PER CHART
SCORE LINES AND EXPANSION JOINTSTYP.
3" CLEAR
B. ALL REINFORCEMENT MUST BE CENTEREDIN CONCRETE PROFILE.
C. CONCRETE COLOR AND FINISH PER PLAN.
CONCRETE PAVING
CONCRETE PAVING CHART
TYPE THICKNESS STRENGTH REBAR
PEDESTRIANCONCRETE
WALKS & SLABS
4" MIN. OVERNATIVE 520-C-2500 #3 BAR AT 18" O.C.
BOTH WAYS
4
CON
STRU
CTIO
N D
ETAI
LS
R1 - 8.30.2021
Date Issued 09.08.21
BID
SET
Date Issued 09.08.21Date Issued 09.08.21Date Issued 09.08.21
obr
GARR
ICK
OLI
VER
C
HRIS
TOPH
ER B
ITTN
ER
AN
NEY
RO
SEN
THAL
-HAL
L
3817
Ray
Str
eet S
an D
iego
, Ca
9210
4e
in
fo@
obra
rchi
tect
ure.
com
w
obra
rchi
tect
ure.
com
t 6
19.5
64.7
586
f 6
19.5
68.3
636
OBRARCHITECTURE, INC. ALL RIGHTSRESERVED. THE ABOVE DRAWINGS, IDEAS,AND EMBODIED DESIGNS THEREIN ARE THEPROPERTY OF OBRARCHITECTURE, INC. ANDSHALL NOT BE COPIED, REPRODUCED,DISCLOSED TO OTHERS OR USED INCONNECTION WITH ANY WORK OTHER THANTHE SPECIFIED PROJECT FOR WHICH THEYHAVE BEEN PREPARED, IN WHOLE OR INPART, WITHOUT THE PRIOR WRITTENAUTHORIZATION OF OBRARCHITECTURE, INC.
Date Issued
Job No.
Sheet No.
CITY
HAL
L /
PUBL
IC L
IBRA
RY P
ROJE
CTCI
TY O
F LA
GUN
A W
OO
DS24
264
El T
oro
Rd, L
agun
a W
oods
, CA
9263
7
8.03.2021
CLW-006
DN BY: AS, BP CK BY: JJ, JT
08.30.2021PLT DATE:
SDG PRJ # 20-105
PERM
IT S
ET
REVISIONSNo.
LC-2.1
1
2
3
4
5
6
8
7
SECTION AT INTERIOR PLANTER
16"
8"
9
NEW MASONRY WALL PER PLANS.1
NEW COMPACTED SUBGRADE2
CONCRETE FOOTING3
ADJACENT ENHANCED CONCRETEPAVING PER PLANS.
4
LANDSCAPE AREA PER PLANTINGPLANS.
5
NEW 8” x 24” x 2.5” CONCRETE WALLCAP. COLOR AND FINISH PER PLANS.
6
3" MULCH7
NEW STUCCO WALL FINISH. COLORAND TEXTURE PER PLANS.
8
FINISHED GRADE9
10
NEW 18" MIN. DEPTH PLANTING SOIL.10
11 WATER PROOFING: TWO LAYERS OFHENRY'S STD. ASPHALT EMULSION NO.107 WITH A LAYER OF FIBERGLASSBETWEEN OR APPROVED EQUAL.
11
12
EXPANSION JOINT12
13
NEW PLANTER DRAIN131
9
1
SECTION AT WEST PLANTER WALL
3
4
56
6
10
8
8
10
7
7
51
11
11
10
10
23
3
6
APPROX.2'-2.5"
APPROX.3'-2.5"
12
EXISTING MASONRY WALL PER PLANS.1
EXISTING COMPACTED SUBGRADE,TYP.
2
EXISTING WALL FOOTING (ASSUMED)3
NEW ADJACENT ENHANCEDCONCRETE PAVING PER PLANS.
4
LANDSCAPE AREA PER PLANTINGPLANS.
5
NEW 8” x 24” x 2.5” CONCRETE WALLCAP. COLOR AND FINISH PER PLANS.
6
3" MULCH7
NEW STUCCO WALL FINISH. COLORAND TEXTURE PER PLANS.
8
EXISTING ADJACENT PAVING.9
NEW PLANTER DRAIN10
NEW 18" MIN. DEPTH PLANTING SOIL11
WATER PROOFING: TWO LAYERS OFHENRY'S STD. ASPHALT EMULSION NO.107 WITH A LAYER OF FIBERGLASSBETWEEN ORAPPROVED EQUAL.
12
13
EXPANSION JOINT, TYP.13
2
SECTION AT ACCESSIBLE RAMP
1
5
4
76
7
2 3
3889
10
5
16"
PERPLAN
6"
8"
11
1
1
12
5
13
1413
15
15
NEW MASONRY WALL PER PLANS.1
NEW COMPACTED SUBGRADE2
NEW CONCRETE FOOTING3
NEW ADJACENT ENHANCEDCONCRETE PAVING PER PLANS.
4
LANDSCAPE AREA PER PLANTINGPLANS.
5
NEW 8” x 24” x 2.5” CONCRETE WALLCAP. COLOR AND FINISH PER PLANS.
6
3" MULCH7
NEW ACCESSIBLE RAMP PER PLANS.8
EXISTING ADJACENT PARKING PERPLANS.
9
NEW 6" CURB AND GUTTER PERPLANS.
10
NEW 18" MIN. DEPTH OF PLANTINGSOIL.
11
NEW 6" CURB PER PLANS.12
WATER PROOFING: TWO LAYERS OFHENRY'S STD. ASPHALT EMULSION NO.107 WITH A LAYER OF FIBERGLASSBETWEEN OR APPROVED EQUAL.
13
EXPANSION JOINT, TYP.14
HANDRAIL PER PLAN. TO MATCHEXISTING WHERE REQUIRED
15
16
16
16
NEW PLANTER DRAINPER PLAN
3'
NOTES:1. #4 REBAR @ 16" OC, HORIZONTAL
2. #4 VERTICAL DOWELS WITH STD 90HK EXTENDED IN THE FOOTING, @16" OC
3 SECTION AT EXTERIOR PERIMETER PLANTER WALLS
13
1
2
3
4
5
67
8
9
10
11
12
14
15
16
EXISTING MASONRY WALL PER PLANS.1
EXISTING SUBGRADE, TYP.2
EXISTING WALL FOOTING (ASSUMED)3
BUILDING FOOTING PER ARCHITECTPLANS.
4
LANDSCAPE AREA PER PLANTINGPLANS.
5
8” x 24” x 2.5” CONCRETE WALL CAP. COLOR AND FINISHPER PLANS.
6
3" MULCH7
ADJACENT BUILDING PER PLANS.8
EXISTING ADJACENT PARKING9
EXISTING CURB10
NEW 18" MIN. DEPTH OF PLANTING SOIL.11
SANDBLAST EXISTING MASONRY WALL AND APPLYSTUCCO FINISH PER CONSTRUCTION NOTES AND PLAN.
12
EXISTING ADJACENT PAVING13
PLANTER DRAIN14
WATER PROOFING: TWO LAYERS OF HENRY'SSTD. ASPHALT EMULSION NO. 107 WITH A LAYEROF FIBERGLASS BETWEEN OR APPROVED EQUAL.
15
EXPANSION JOINT. TYP.16
4
TYPICAL WALL CONSTRUCTION NOTES:*NOTES APPLY TO ALL DETAILS THIS SHEET.
A. SEE CONSTRUCTION SHEET LC-1.0 FOR WALLCONSTRUCTION NOTES, LEGEND AND PLAN.
B. ALL NEW WALL CONSTRUCTION SHALL INCLUDE #4REBAR @ 16" O.C. HORIZONTALLY.
C. ALL NEW WALL CONSTRUCTION SHALL INCLUDE #4VERTICAL DOWELS WITH STD 90 HK EXTENDEDEXTENDED INTO THE FOOTING @ 16" O.C.
D. FOOTING WIDTH 2'-0" MIN.
E. FOOTING DEPTH 1'-0" MIN. W/ (2) #4 LONGITUDINALBARS.
F. ALL NEW AND EXISTING WALLS SHALL RECEIVE NEWPRECAST CONCRETE CAP BLOCK. SECURE CAP BLOCKTO WALL PER MANUFACTURER'S RECOMMENDATIONS.
G. SEE CONSTRUCTION NOTES AND ARCHITECTURALPLANS FOR STUCCO TREATMENT.
H. ALL COLORS SHALL BE SELECTED BY THE CITY ANDMOCKUPS PROVIDED FOR FINAL APPROVAL PRIOR TOINSTALLATION.
I. COORDINATE ALL WALL CONSTRUCTION WITHARCHITECTURAL AND STRUCTURAL PLANS.
J. COORDINATE ALL DRAINAGE WITH CIVIL PLANS.
CON
STRU
CTIO
N D
ETAI
LS
Date Issued 09.08.21
BID
SET
Date Issued 09.08.21Date Issued 09.08.21Date Issued 09.08.21
EL T
OR
O R
D.
WILLOW TREE CENTER ACCESS ROAD
2"
----
--
--
5
6
87
PROTECT EXISTING SPRAYIRRIGATION IN PLACE
EXISTING VALVE 8 TO BE PROTECTED INPLACE. REPAIR AND ADJUST LATERALS,
HEADS AND NOZZLES ON THIS CIRCUITAS NECESSARY TO PROVIDE 100% HEAD
TO HEAD COVERAGE.
CONTRACTOR TO FIELD VERIFY LOCATION OFEXISTING VALVE 5. REPLACE VALVE 5 WITHNEW REMOTE CONTROL VALVE AND CONNECTLATERAL LINE TO EXISTING PLANTERS AROUNDTHE BACKSIDE OF THE CITY HALL BUILDING.
EXISTING VALVE 6 TO BE PROTECTED IN PLACE.REPAIR AND ADJUST HEADS, LATERALS ANDNOZZLES ON THIS CIRCUIT AS NECESSARY TOPROVIDE 100% HEAD TO HEAD COVERAGE INAREAS AFFECTED BY NEW CONSTRUCTION.
EXISTING IRRIGATION MAINLINE TO WATERMETER. CONTRACTOR TO FIELD VERIFYLOCATION OF METER ON EL TORO RD.
PROTECT EXISTING SPRAYIRRIGATION IN PLACE
CUT & CAP EXISTING LATERALLINE WITH SOLVENT WELD PVCCAP AT THE EDGE OF PLATNER
PROTECT EXISTING SPRAYIRRIGATION IN PLACE, TYP.
CONTRACTOR TO INTERCEPT EXISTING IRRIGATIONMAINLINE (AND WIRES IF PRESENT) FOR USE WITHNEW POINT OF CONNECTION EQUIPMENT. SEEIRRIGATION PLAN AND DETAILS.
PROTECT EXISTING IRRIGATION MAINLINE BELOWASPHALT PAVING IN PLACE. TRENCH ADJACENT TO THE
IRRIGATION MAINLINE FOR NEW COMMUNICATIONSCONDUIT FROM EXISTING CONTROLLER TO NEW POINT
OF CONNECTION EQUIPMENT. SEE IRRIGATION PLAN.
INTERCEPT EXISTING IRRIGATION MAINLINE AND WIRES INPLANTER BEHIND EXISTING WALL FOR USE WITH NEWIRRIGATION MAINLINE AND WIRES AT NEW IMPROVEMENTS.
- -
-
-
1
2
3 .
EXISTING 12 STATION IRRIGATIONCONTROLLER IN STAINLESS STEELPEDESTAL. PROTECT PEDESTAL AND ALLUTILITY CONNECTIONS IN PLACE. SEEIRRIGATION PLAN FOR CONTROLLER WORK.
EXISTING CITYHALL BLDG.
WILLOW TREE CENTER ACCESS ROAD
EL T
OR
O R
D.
EXISTING VALVE 7 TO BEPROTECTED IN PLACE.
REMOVE AND DISPOSE OF ALL EXISTINGIRRIGATION EQUIPMENT WHERE INDICATED.
REMOVE AND DISPOSE OF ALL EXISTINGIRRIGATION EQUIPMENT WHERE INDICATED.CONTRACTOR SHALL USE CARE WHENWORKING AROUND MATURE PLANT MATERIALSTO REMAIN. REFER TO ALL PROJECT PLANSFOR COORDINATION OF NEW WORK HERE.
PROTECT EXISTINGUTILITIES IN PLACE, TYP.
UNLESS OTHERWISENOTED ON THE PLANS.
CONTRACTOR TO PROVIDE A NEW PENETRATION OR PATH FOR NEWIRRIGATION CONDUIT THROUGH OR BELOW EXISTING MASONRY WALLFOR NEW COMMUNICATIONS CONDUIT. ALL CONDUIT PENETRATIONSTO BE BELOW EXISTING AND/OR NEW FINISHED GRADE. EXPOSEDCONDUIT IS NOT ACCEPTABLE. SEE IRRIGATION PLAN FOR WORK.
PROTECT EXISTING IRRIGATIONMAINLINE AND WIRES BELOWASPHALT PAVING IN PLACE, TYP.
NOTE: REFER TO CIVILAND ARCHITECTURAL
PLANS FOR ALL OTHERSITE DEMOLITION
WORK.
C
PROTECT EXISTING IRRIGATIONMAINLINE AND WIRES IN PLACE, TYP.
C
SYMBOL MANUFACTURER/MODEL/DESCRIPTION
EXISTING REMOTE CONTROLL VALVE: RAINBIRD PESB-PRS-D
EXISTING HUNTER PC-1200 12 STATION CONTROLLER INSTAINLESS STEEL ENCLOSURE. PROTECT ENCLOSURE ANDUTILITIES IN PLACE. STATIONS 1-8 OCCUPIED WITH EXISTINGIRRIGATION. SEE IRRIGATION PLANS FOR CONTROLLER WORK
EXISTING PVC SCHEDULE 40 IRRIGATION LATERAL LINE
EXISTING PVC SCHEDULE 40 IRRIGATION MAINLINE
INTERCEPT IRRIGATION MAINLINE, WIRES AND LATER LINESWHERE INDICATED
--
# EXISTING VALVE CALLOUT
obr
GARR
ICK
OLI
VER
C
HRIS
TOPH
ER B
ITTN
ER
AN
NEY
RO
SEN
THAL
-HAL
L
3817
Ray
Str
eet S
an D
iego
, Ca
9210
4e
in
fo@
obra
rchi
tect
ure.
com
w
obra
rchi
tect
ure.
com
t 6
19.5
64.7
586
f 6
19.5
68.3
636
OBRARCHITECTURE, INC. ALL RIGHTSRESERVED. THE ABOVE DRAWINGS, IDEAS,AND EMBODIED DESIGNS THEREIN ARE THEPROPERTY OF OBRARCHITECTURE, INC. ANDSHALL NOT BE COPIED, REPRODUCED,DISCLOSED TO OTHERS OR USED INCONNECTION WITH ANY WORK OTHER THANTHE SPECIFIED PROJECT FOR WHICH THEYHAVE BEEN PREPARED, IN WHOLE OR INPART, WITHOUT THE PRIOR WRITTENAUTHORIZATION OF OBRARCHITECTURE, INC.
Date Issued
Job No.
Sheet No.
CITY
HAL
L /
PUBL
IC L
IBRA
RY P
ROJE
CTCI
TY O
F LA
GUN
A W
OO
DS24
264
El T
oro
Rd, L
agun
a W
oods
, CA
9263
7
8.03.2021
CLW-006
DN BY: AS, BP CK BY: JJ, JT
08.30.2021PLT DATE:
SDG PRJ # 20-105
PERM
IT S
ET
REVISIONSNo.
LD-1.0
IRRI
GATI
ON
DEM
OLI
TIO
N P
LAN
1. SUMMARYA. CLEAR AND GRUB THE PROJECT SITE PRIOR TO CONSTRUCTION, AS
SPECIFIED HEREIN, AND AS NEEDED FOR A COMPLETE AND PROPERPREPARATION OF THE SITE.
B. LOCATION AND ELEVATION OF ALL EXISTING IMPROVEMENTS WITHINTHE AREA OF WORK SHALL BE CONFIRMED BY FIELD MEASUREMENTPRIOR TO CONSTRUCTION OF NEW WORK.
C. CONTRACTOR TO LOCATE EXISTING UTILITIES IN FIELD PRIOR TOCOMMENCEMENT OF WORK.
D. DEMOLITION ITEMS ON THIS PLAN ARE FOR CONTRACTOR REFERENCEONLY. CONTRACTOR IS RESPONSIBLE FOR REMOVAL OF ALL EXISTINGABOVE AND UNDERGROUND STRUCTURES AS NECESSARY TOCONSTRUCT PROJECT.
2. PROJECT CONDITIONSA. TRAFFIC: CONDUCT SITE PREPARATION WORK TO ENSURE MINIMUM
INTERFERENCE WITH EXISTING ROADS, STREETS, WALKS AND OTHERADJACENT OCCUPIED OR USED FACILITIES. DO NOT CLOSE OROBSTRUCT EXISTING STREETS, WALKS OR OTHER OCCUPIED OR USEDFACILITIES WITHOUT PERMISSION FROM AUTHORITIES HAVINGJURISDICTION.
B. COMPLETE THE CLEARING AND SITE PREPARATION WORK BEFORESTARTING EARTHWORK. ERECT TEMPORARY CONSTRUCTION FENCING,BARRICADES, ENCLOSURES, AND PROTECTION OF ADJACENTPROPERTY AND EXISTING WORK BEFORE STARTING SITE CLEARINGWORK AND MAINTAIN FOR THE DURATION OF WORK.
C. INSPECT AND REVIEW THE PROJECT SITE TO DETERMINE EXISTINGCONDITIONS WHICH AFFECT CONSTRUCTION OPERATIONS. IT SHALL BETHE RESPONSIBILITY OF THE CONTRACTOR TO LOCATED ALLSUBSTRUCTURES, WHETHER SHOWN HEREON OR NOT, AND PROTECTTHEM FROM DAMAGE. THE EXPENSE OF REPAIR OR REPLACEMENT OFSAID SUBSTRUCTURES SHALL BE BORNE BY THE CONTRACTOR. ALLEXISTING IRRIGATION LATERALS, HEADS, AND MAINLINES DISTURBEDWITHIN CONSTRUCTION LIMIT LINES SHALL BE ADJUSTED TO NEWCONSTRUCTION. AFFECTED IRRIGATION ZONES SHALL BE SHUT OFFWITHIN AREAS OF DISTURBANCE. ALL CONSTRUCTION IN THESE AREASSHALL BE COMPLETED IN A TIMELY FASHION TO PREVENT EXISTINGVEGETATION FROM STRESS, WILT, OR DYING.
D. PROTECTION OF EXISTING TREES AND VEGETATION: PROTECT EXISTINGTREES AND OTHER VEGETATION INDICATED TO REMAIN IN PLACE,AGAINST CUTTING, BREAKING, OR SKINNING OF ROOTS, SKINNING ANDBRUISING OF BARK, SMOTHERING OF TREES BY STOCKPILINGCONSTRUCTION MATERIALS OR EXCAVATED MATERIALS WITHIN DRIPLINE. PROVIDE TEMPORARY GUARDS TO PROTECT TREES ANDVEGETATION TO REMAIN. SEE ALSO SPECIFICATIONS.
3. DISPOSITION OF MATERIALSA. REMOVE MATERIAL EXCEPT THOSE ITEMS INDICATED TO BE RE-USED TO
A LEGAL DISPOSAL AREA.B. STOCKPILING OF REMOVED MATERIALS ON THE PROJECT SITE WILL NOT
BE PERMITTED WITHOUT WRITTEN APPROVAL FROM THE RESIDENTENGINEER.
IRRIGATION DEMOLITION NOTES:
IRRIGATION DEMOLITION LEGEND:
REMOVE AND DISPOSE OF ALL EXISTING IRRIGATION EQUIPMENTWITHIN THESE AREAS.
PROTECT EXISTING IRRIGATION SPRAY EQUIPMENT, HEADS,VALVES, WIRES, LATERALS, ETC. WITHIN THESE AREAS.
5 10 20
1" = 10'-0"SCALE :
0
NORTH
ANTICIPATED TRENCHING FOR NEW MASTER VALVE AND FLOWSENSOR COMMUNICATIONS CONDUIT.
Date Issued 09.08.21
BID
SET
Date Issued 09.08.21Date Issued 09.08.21Date Issued 09.08.21
SYMBOL MANUFACTURER/MODEL ARC PSI GPM RADIUS DETAIL
RAIN BIRD 1812-SAM-PRS 15 STRIP SERIES LCS 30 0.49 4'x15'
HUNTER RZWS-SLEEVE-36-CV 50 360 30 0.50 3'
SYMBOL MANUFACTURER/MODEL/DESCRIPTION DETAIL
HUNTER ICZ-101-25 DRIP CONTROL ZONE KIT. 1" ICV GLOBE VALVEWITH 1" HY100 FILTER SYSTEM. PRESSUREREGULATION: 25PSI. FLOW RANGE: 2 GPM TO 20GPM. 150 MESH STAINLESS STEEL SCREEN.
NETAFIM TL050MFV-1 AUTOMATIC FLUSH VALVE, 1/2" MALE PIPETHREAD.
AREA TO RECEIVE DRIPLINENETAFIM TLCV-09-12 TECHLINE PRESSURE COMPENSATINGLANDSCAPE DRIPLINE WITH CHECK VALVE. 0.9GPH EMITTERS AT 12" O.C. DRIPLINE LATERALSSPACED AT 12" APART, WITH EMITTERS OFFSETFOR TRIANGULAR PATTERN. 17MM. CONTRACTORTO PROVIDE ONE HUNTER ECO-ID DRIP SYSTEMINDICATOR ON SWING JOINT FOR EACH DRIPCIRCUIT.
SYMBOL MANUFACTURER/MODEL/DESCRIPTION DETAIL
HUNTER PGV-100-MM 1" PLASTIC ELECTRIC REMOTE CONTROL VALVE,FOR RESIDENTIAL/LIGHT COMMERCIAL USE. MALEX MALE (NPT THREAD) INLET/OUTLET. GLOBECONFIGURATION, NO FLOW CONTROL.
HUNTER HQ-44LRC QUICK COUPLER VALVE, YELLOW RUBBERLOCKING COVER, RED BRASS AND STAINLESSSTEEL, WITH 1" NPT INLET, 2-PIECE BODY.
NIBCO T-FP-600A BRASS BODY FULL PORT SHUT OFF VALVE WITHSTAINLESS STEEL BALL. LINE SIZE AS REQUIRED.
BUCKNER-SUPERIOR 3200 2"NORMALLY CLOSED BRASS MASTER VALVE THATPROVIDES DIRTY WATER PROTECTION AND NOMINIMUM FLOW FEATURE FOR RELIABLE OPENINGAND CLOSING OF THE VALVE IN EXTREME HIGHOR LOW FLOW SCENARIOS.
HUNTER FLOW-CLIK WITH FCT 100 FLOW SENSOR FLOW SENSOR SOV WITH INTERFACE PANEL, 1"SCHEDULE 40 SENSOR BODY, 24 VAC, 2 AMP,INSTALL INTERFACE PANEL WITHIN EXSITINGCONTROLLER CABINET AS REQUIRED.
STUB-OUT IRRIGATION MAINLINE FOR FUTURE USE CONTRACTOR TO PROVIDE SOLVENT WELD PVCCAP ON THE IRRIGATION MAINLINE IN ROUNDPLASTIC VALVE BOX WITHIN THE LANDSCAPEPLANTER AREA.
IRRIGATION LATERAL LINE: PVC SCHEDULE 40
IRRIGATION MAINLINE: PVC SCHEDULE 40 FOR 1.5" AND SMALLER PIPEPVC CLASS 315 FOR 2" AND LARGER PIPE
IRRIGATION MAINLINE: EXISTING PVC SCHEDULE 40
PIPE SLEEVE: PVC SCHEDULE 40 TYPICAL PIPE SLEEVE FOR IRRIGATION PIPE. PIPESLEEVE SIZE SHALL BE MIN. 2X PIPE DIAMETERSIZE AND ALLOW FOR IRRIGATION PIPING ANDTHEIR RELATED COUPLINGS TO EASILY SLIDETHROUGH SLEEVING MATERIAL. EXTENDSLEEVES 18 INCHES BEYOND EDGES OF PAVINGTYP.
MV
IRRIGATION LEGEND:
1/LI-2.0
2/LI-2.0
3&7/LI-2.0,9/LI-2.1
4/LI-2.0
5&6/LI-2.0
7/LI-2.0,1&9/LI-2.1
7,LI-2.0,2/LI-2.1
7/LI-2.0,3/LI-2.1
4&9/LI-2.1
5&9/LI-2.1
6/LI-2.1
7&8/LI-2.1
7,8&9//LI-2.1
TYP.
Valve Number
Valve FlowValve Size
Valve Callout
###"
EXISTING POP-UP SPRAY IRRIGATION SYSTEMS,PROTECT IN PLACE UNLESS OTHERWISE NOTED.
C C NEW 1 1/2" PVC CONDUIT AND WIRES FOR MASTERVALVE AND FLOW SENSOR COMMUNICATION.
4,5&9/LI-2.1
VALVE SCHEDULE:
NUMBER MODEL SIZE TYPE GPM PSI PRECIP1 HUNTER PGV-100-MM 1" BUBBLER 3.00 31.73 1.77 in/h2 HUNTER ICZ-101-25 1" AREA FOR DRIPLINE 12.62 49.35 1.44 in/h3 HUNTER PGV-100-MM 1" AREA OF EXISTING POP-UP SHRUB SPRAY HEADS 5.01 34.66 2 in/h4 HUNTER ICZ-101-25 1" AREA FOR DRIPLINE 2.13 40.01 1.44 in/h5 HUNTER PGV-100-MM 1" BUBBLER 4.00 32.02 1.92 in/h6 HUNTER ICZ-101-25 1" AREA FOR DRIPLINE 4.92 40.42 1.44 in/h7 HUNTER ICZ-101-25 1" AREA FOR DRIPLINE 4.94 40.22 1.45 in/h8 HUNTER ICZ-101-25 1" AREA FOR DRIPLINE 3.95 40.73 1.44 in/h9 HUNTER PGV-100-MM 1" AREA OF EXISTING POP-UP SHRUB SPRAY HEADS - - Existing10 HUNTER PGV-100-MM 1" AREA OF EXISTING POP-UP SHRUB SPRAY HEADS - - Existing11 HUNTER PGV-100-MM 1" AREA OF EXISTING POP-UP SHRUB SPRAY HEADS - - ExistingSTUB-OUT STUB-OUT FOR FUTURE USE 1.5" CAP (AS INDICATED FOR FUTURE USE) 30.00 40.00 -
Generated: 2020-09-16 19:24
P.O.C. NUMBER: 01Water Source Information: Water Pressure on El Toro
per El Toro Water District
FLOW AVAILABLEWater Meter Size: 1-1/2"Flow Available: 70.55 gpm
PRESSURE AVAILABLEStatic Pressure at POC: 82.00 psiElevation Change: 5.00 ftService Line Size: 2"Length of Service Line: 20.00 ftPressure Available: 79.00 psi
DESIGN ANALYSISMaximum Station Flow: 30.00 gpmFlow Available at POC: 70.55 gpmResidual Flow Available: 40.55 gpm
Critical Station: 2 Design Pressure: 30.00 psi Friction Loss: 0.15 psi Fittings Loss: 0.02 psi Elevation Loss: 0.00 psi Loss through Valve: 19.18 psiPressure Req. at Critical Station: 49.35 psiLoss for Fittings: 0.13 psiLoss for Main Line: 1.26 psiLoss for POC to Valve Elevation: 0.00 psiLoss for Backflow: 11.00 psiLoss for Master Valve: 0.53 psiLoss for Water Meter: 0.28 psiCritical Station Pressure at POC: 51.55 psiPressure Available: 68.00 psiResidual Pressure Available: 16.45 psi
CRITICAL ANALYSIS1. THE IRRIGATION SYSTEM DESIGN IS BASED ON AN AVAILABLE WATER PRESSURE OF 82 PSI AT EXISTING CITY METER
SERVICE ALONG EL TORO ROAD. CONTRACTOR SHALL VERIFY WATER PRESSURE PRIOR TO CONSTRUCTION ANDREPORT ANY DIFFERENCES TO THE CITY OF LAGUNA WOODS.
2. LOCATION OF IRRIGATION LINES AND SYMBOLS ARE DIAGRAMMATIC. ALL IRRIGATION SHALL BE PLACED IN PLANTINGAREAS EXCEPT WHEN CROSSING PAVEMENT UNLESS NOTED OR DIRECTED OTHERWISE. LOCATE ALL VALVES ANDVALVE BOXES SIX INCHES FROM EDGE OF PAVING OR CURB.
3. EXISTING UTILITIES AND FIELD CONDITIONS: PRIOR TO EXCAVATION, LOCATE ALL CABLES, CONDUITS, ANDUNDERGROUND UTILITIES. CONTRACTOR SHALL BE RESPONSIBLE FOR AN UNDERGROUND UTILITY SERVICE TO LOCATEAND MARK UTILITIES. CONTRACTOR WILL TAKE PROPER PRECAUTIONS NOT TO DAMAGE OR DISTURB SUCHUNDERGROUND IMPROVEMENTS. NOTIFY THE OWNER IMMEDIATELY IF A CONFLICT EXISTS BETWEEN SUCH OBSTACLESAND THE PROPOSED WORK. PROCEED IN SAME MANNER IF ROCK LAYERS OR ANY OTHER CONDITIONS ENCOUNTEREDUNDERGROUND MAKE CHANGES ADVISABLE.
4. ALL PIPING AND WIRING UNDER ROADWAYS AND PAVING AND THROUGH WALLS SHALL BE SLEEVED.
5. USE FOUR WRAPS OF THREE-QUARTER INCH (3/4") TEFLON TAPE FOR ALL THREADED VALVE CONNECTIONS.
6. AUTOMATIC IRRIGATION CONTROLLER IS EXISTING TO BE PROTECTED IN PLACE. THE CONTRACTOR SHALL BERESPONSIBLE FOR CONNECTION OF FIELD WIRES TO APPROPRIATE TERMINAL STRIPS, INSTALLATION AND CONNECTIONOF FLOW SENSOR MODULE AND 120V POWER.
7. ADJUST ALL SPRINKLERS TO AVOID OVER SPRAY ONTO WALLS, WALKS, STREETS, UTILITY BOXES, BUILDINGS AND OTHERIMPROVEMENTS.
8. ALL SPRINKLER HEADS SHALL BE SET PERPENDICULAR TO THE FINISH GRADE OF THE AREA TO BE IRRIGATED UNLESSOTHERWISE DESIGNED ON THE PLANS.
9. NO LOW HEAD DRAINAGE ALLOWED. CONTRACTOR SHALL INSTALL IN-LINE ANTI-DRAIN VALVES AS WARRANTED BY SITECONDITIONS TO ALLEVIATE LOW HEAD DRAINAGE.
10. THE CONTRACTOR SHALL NOT WILLFULLY INSTALL THE SPRINKLER SYSTEM AS SHOWN ON THE DRAWINGS WHEN IT ISOBVIOUS IN THE FIELD THAT OBSTRUCTIONS, GRADE DIFFERENCES OR DIFFERENCES IN THE AREA DIMENSIONS. SUCHOBSTRUCTIONS OR DIFFERENCES SHALL BE BROUGHT TO THE ATTENTION OF THE LANDSCAPE ARCHITECT. IN THEEVENT THIS NOTIFICATION IS NOT PERFORMED, THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY REVISIONSNECESSARY.
11. THE CONTRACTOR SHALL KEEP AN UP-TO-DATE COMPLETE "AS-BUILT" RECORD SET OF PRINTS WHICH SHALL BEUPDATED DAILY AND SHOW EVERY CHANGE FROM THE ORIGINAL DESIGN.
12. INSTALL IRRIGATION HEADS IN TURF AREAS 2" FROM WALKS AND HARDSCAPE AREAS.
13. ALL CONTROL VALVES SHALL BE MANIFOLDED AND GROUPED IN ONE AREA SHOWN ON PLAN. VALVES SHALL BE SET ATRIGHT ANGLES TO EDGES. INSTALL VALVES BOXES 6" FROM EDGES OF HARDSCAPE AREAS.
14. CONTRACTOR SHALL REMOVE AND DISCARD DAILY, ALL PIPING DISTURBED DURING TRENCHING OPERATION.
15. CONTRACTOR SHALL REVIEW IRRIGATION SPECIFICATIONS PRIOR TO BEGINNING WORK. REFER TO TECHNICALSPECIFICATIONS AND CONSTRUCTION DETAILS FOR INSTALLATION PROCEDURES.
16. CONTRACTOR SHALL HEAT BRAND ALL PLASTIC VALVES BOXES WITH THE FOLLOWING LABELS. ALL LETTERS SHALL BEONE INCH (1") HIGH. LETTERING ON VALVE BOX LIDS SHALL BE PLACED ON THE SAME LOCATION ON EACH VALVE BOXLID, AND ALL LABELING SHALL FACE THE SAME DIRECTION.
QUICK COUPLER VALVE BOXES SHALL BE LABELED "QCV"BALL VALVE BOXES "BV"
17. ALL BOLTS FOR LOCKING VALVE BOX LIDS SHALL BE STAINLESS STEEL.
18. CONTRACTOR SHALL CONTACT CITY OF LAGUNA WOODS INSPECTOR PRIOR TO ANY TRENCHING OPERATIONS.
19. PROVIDE CONCRETE THRUST BLOCKS ON ALL MAINLINES 2-1/2" AND GREATER, PER DETAIL AND SPECIFICATIONS.
20. THE CITY OF LAGUNA WOODS INSPECTION DEPARTMENT SHALL BE NOTIFIED 48 HOURS (2 WORKING DAYS) PRIOR TOTHE START OF CONSTRUCTION. ALL WORK PERFORMED WITHOUT BENEFIT OF INSPECTION SHALL BE SUBJECT TOREJECTION AND REMOVAL.
IRRIGATION NOTES:
obr
GARR
ICK
OLI
VER
C
HRIS
TOPH
ER B
ITTN
ER
AN
NEY
RO
SEN
THAL
-HAL
L
3817
Ray
Str
eet S
an D
iego
, Ca
9210
4e
in
fo@
obra
rchi
tect
ure.
com
w
obra
rchi
tect
ure.
com
t 6
19.5
64.7
586
f 6
19.5
68.3
636
OBRARCHITECTURE, INC. ALL RIGHTSRESERVED. THE ABOVE DRAWINGS, IDEAS,AND EMBODIED DESIGNS THEREIN ARE THEPROPERTY OF OBRARCHITECTURE, INC. ANDSHALL NOT BE COPIED, REPRODUCED,DISCLOSED TO OTHERS OR USED INCONNECTION WITH ANY WORK OTHER THANTHE SPECIFIED PROJECT FOR WHICH THEYHAVE BEEN PREPARED, IN WHOLE OR INPART, WITHOUT THE PRIOR WRITTENAUTHORIZATION OF OBRARCHITECTURE, INC.
Date Issued
Job No.
Sheet No.
CITY
HAL
L /
PUBL
IC L
IBRA
RY P
ROJE
CTCI
TY O
F LA
GUN
A W
OO
DS24
264
El T
oro
Rd, L
agun
a W
oods
, CA
9263
7
8.03.2021
CLW-006
DN BY: AS, BP CK BY: JJ, JT
08.30.2021PLT DATE:
SDG PRJ # 20-105
PERM
IT S
ET
REVISIONSNo.
LI-1.0
IRRI
GATI
ON
LEG
END
& N
OTE
S
IRRIGATION DESIGN IS BASED UPON A MAXIMUM OPERATING PRESSURE OF 82 PSIWITH A MAXIMUM DEMAND OF 75 GPM AT THE POINT OF CONNECTION.WATER COMPANY: EL TORO WATER DISTRICTPHONE NUMBER: 949-837-7050
SIGNATURE DATE
DECLARATION OF RESPONSIBLE CHARGE:
JEFF JUSTUS REGISTRATION NO. 4028
JEFF JUSTUS, PRINCIPAL, ASLASCHMIDT DESIGN GROUP, INC.1111 6TH AVE, STE 500SAN DIEGO, CA 92101PHONE NO. (619) 236-1462EMAIL: [email protected]
I HEREBY DECLARE THAT I AM THE LANDSCAPEARCHITECT OF WORK FOR THIS PROJECT, THAT I HAVEEXERCISED RESPONSIBLE CHARGE OVER THE DESIGN OFTHIS PROJECT AS DEFINED IN SECTION 6703 OF THEBUSINESS AND PROFESSIONS CODE, AND THAT THEDESIGN IS CONSISTENT WITH CURRENT STANDARDS. IHAVE COMPLIED WITH THE CRITERIA OF THE WATEREFFICIENT LANDSCAPE ORDINANCE AND APPLIED THEMACCORDINGLY FOR THE EFFICIENT USE OF WATER IN THEIRRIGATION DESIGN PLAN. I UNDERSTAND THAT THECHECK OF THE PROJECT DRAWINGS AND SPECIFICATIONSBY THE CITY IS CONFINED TO A REVIEW ONLY AND DOESNOT RELIEVE ME, AS THE LANDSCAPE ARCHITECT OFWORK, OF MY RESPONSIBILITIES FOR PROJECT DESIGN.
8/30/2021WATER USE CALCULATIONS:SEE SHEET LI-1.2 FOR WATER EFFICIENT LANDSCAPE ORDINANCE CALCULATIONS.
Date Issued 09.08.21
BID
SET
Date Issued 09.08.21Date Issued 09.08.21Date Issued 09.08.21
EL T
OR
O R
D.
WILLOW TREE CENTER ACCESS ROAD
UP
863 SFLIBRARY
131 SFOFFICE
80 SFRESTROOM87 SF
STORAGE
573 SF
OUTDOOR ACTIVITYSPACE
EXISTING CITYHALL BLDG.
PROPOSEDLIBRARY
BLDG.
C
CONTRACTOR TO FIELD VERIFY LOCATION OFEXISTING VALVE 5. REPLACE VALVE 5 WITH NEWREMOTE CONTROL VALVE AND CONNECT LATERALLINE TO EXISTING PLANTERS AROUND THE BACKSIDEOF THE CITY HALL BUILDING. CONVERT THIS SYSTEMTO SUB-SURFACE DRIP IRRIGATION, TYPICAL.RE-SEQUENCE VALVE AS INDICATED.
CONTRACTOR TO POTHOLE ANDINTERCEPT EXISTING PVC IRRIGATION
LATERAL LINE TO EXISTING POP-UP SPRAYHEADS IN ADJACENT PLANTER AREA.
EXTEND NEW 3/4" PVC LATERAL LINE TONEW SPRAY HEADS IN BIOFILTRATION UNIT.
CONTRACTOR TO COORDINATE LATERALLINE PENETRATION WITH PRODUCT
VENDOR PRIOR TO AND DURING ORDER TOAVOID FIELD MODIFICATION TO THE UNIT.
MV
EXISTING VALVE 6, PROTECTIN PLACE. RE-SEQUENCE ASINDICATED.
EXISTING VALVE 8 TO BE PROTECTED INPLACE. REPAIR AND ADJUST HEADS AND
NOZZLES WHERE DISTURBED ON THISCIRCUIT AS NECESSARY TO PROVIDE
100% HEAD TO HEAD COVERAGE.RE-SEQUENCE VALVE AS INDICATED.
NEW SLEEVE FORLATERAL LINES. 2X
PIPE DIAMETER, TYP.
PROVIDE SLEEVE AND WALLPENETRATION BELOW FINISHED
GRADE FOR LATERAL LINESWHERE REQUIRED, TYPICAL
INSTALL NEW MASTER VALVE, FLOW SENSOR ANDSHUT OFF VALVES WHERE IRRIGATION MAINLINEENTERS THE PLANTER AND AHEAD OF THEPERPENDICULAR IRRIGATION MAINLINE ALONG ELTORO RD AND ALL OTHER VALVES ON THIS SYSTEM.
NOTE: IRRIGATION MAINLINE AND EQUIPMENT ISSHOWN DIAGRAMMATICALLY IN PAVEMENT FORCLARITY. INSTALL ALL IRRIGATION EQUIPMENTIN PLANTER AREAS WHEREVER POSSIBLE, TYP.
CONTRACTOR TO INVESTIGATE THE EXISTING RAISEDPLANTERS AROUND THE PERIMETER OF THE CITYHALL BUILDING FOR LEAKS AND DAMAGE. REMOVEEXISTING SCH. 80 PVC RISERS IN EACH PERIMETERPLANTER AND USE EXISTING LATERAL LINE TOCONVERT THE PLANTER AREAS TO DRIP IRRIGATIONSYSTEMS. WHERE LATERAL LINES MAY BE DAMAGEDOR NON-FUNCTIONAL, THE CONTRACTOR SHALLEXTEND NEW PVC LATERAL LINES TO PROVIDE 100%FUNCTIONALITY TO THE PLANTER AREAS.
13.001"
213.81"
83.951"
C C C C C C C C C C C C
CC
54.001"
64.921"
42.131"
.-1"
10-1"
11-1"
CONTRACTOR TO INSTALL HUNTER FLOW CLIK INTERFACEPANEL MODULE IN EXISTING STAINLESS STEEL PEDESTALAND CONNECT TO 120V POWER SOURCE IN CABINET.
RECONNECT MAINLINE FROM NEW MASTERVALVE AND FLOW SENSOR AHEAD OF ALLVALVES ON THE CITY HALL SYSTEM.
34"
34"
34"
34"
STUB-OUT IRRIGATIONMAINLINE IN VALVE BOX INPLANTER FOR FUTURE USE.
74.941"
EXISTING VALVE 7,PROTECT IN PLACE.RE-SEQUENCEVALVE AS INDICATED.
34"
2"
112"
112"
114"
35.011"
CONNECT NEW 1" LATERAL LINE TO EXISTINGPOP-UP SPRAY IRRIGATION SYSTEM TO
MAINTAIN 100% FUNCTIONALITY IN ORPHANEDPLANTER ISLAND. REPAIR HEADS, NOZZLES
AND LATERALS AS REQUIRED TO PROVIDE 100%HEAD TO HEAD COVERAGE IN THE PLANTER.
34" 34"
2"
112"
2"
2"
PROVIDE SLEEVE AND WALLPENETRATION BELOW FINISHED
GRADE FOR LATERAL LINESWHERE REQUIRED, TYP.
1"
CONTRACTOR TO STUB-OUT IRRIGATIONMAINLINE IN VALVE BOX WITH 3 SPARE CONTROL
WIRES AND 1 COMMON WIRE FOR FUTURE USE.
obr
GARR
ICK
OLI
VER
C
HRIS
TOPH
ER B
ITTN
ER
AN
NEY
RO
SEN
THAL
-HAL
L
3817
Ray
Str
eet S
an D
iego
, Ca
9210
4e
in
fo@
obra
rchi
tect
ure.
com
w
obra
rchi
tect
ure.
com
t 6
19.5
64.7
586
f 6
19.5
68.3
636
OBRARCHITECTURE, INC. ALL RIGHTSRESERVED. THE ABOVE DRAWINGS, IDEAS,AND EMBODIED DESIGNS THEREIN ARE THEPROPERTY OF OBRARCHITECTURE, INC. ANDSHALL NOT BE COPIED, REPRODUCED,DISCLOSED TO OTHERS OR USED INCONNECTION WITH ANY WORK OTHER THANTHE SPECIFIED PROJECT FOR WHICH THEYHAVE BEEN PREPARED, IN WHOLE OR INPART, WITHOUT THE PRIOR WRITTENAUTHORIZATION OF OBRARCHITECTURE, INC.
Date Issued
Job No.
Sheet No.
CITY
HAL
L /
PUBL
IC L
IBRA
RY P
ROJE
CTCI
TY O
F LA
GUN
A W
OO
DS24
264
El T
oro
Rd, L
agun
a W
oods
, CA
9263
7
8.03.2021
CLW-006
DN BY: AS, BP CK BY: JJ, JT
08.30.2021PLT DATE:
SDG PRJ # 20-105
PERM
IT S
ET
REVISIONSNo.
LI-1.1
IRRI
GATI
ON
PLA
N
5 10 20
1" = 10'-0"SCALE :
0
NORTH
1. SEE SHEET LI-1.0 FOR IRRIGATION LEGEND AND NOTES2. SEE SHEETS LI-2.0 - LI-2.1 FOR IRRIGATION DETAILS
GENERAL NOTES:
Date Issued 09.08.21
BID
SET
Date Issued 09.08.21Date Issued 09.08.21Date Issued 09.08.21
obr
GARR
ICK
OLI
VER
C
HRIS
TOPH
ER B
ITTN
ER
AN
NEY
RO
SEN
THAL
-HAL
L
3817
Ray
Str
eet S
an D
iego
, Ca
9210
4e
in
fo@
obra
rchi
tect
ure.
com
w
obra
rchi
tect
ure.
com
t 6
19.5
64.7
586
f 6
19.5
68.3
636
OBRARCHITECTURE, INC. ALL RIGHTSRESERVED. THE ABOVE DRAWINGS, IDEAS,AND EMBODIED DESIGNS THEREIN ARE THEPROPERTY OF OBRARCHITECTURE, INC. ANDSHALL NOT BE COPIED, REPRODUCED,DISCLOSED TO OTHERS OR USED INCONNECTION WITH ANY WORK OTHER THANTHE SPECIFIED PROJECT FOR WHICH THEYHAVE BEEN PREPARED, IN WHOLE OR INPART, WITHOUT THE PRIOR WRITTENAUTHORIZATION OF OBRARCHITECTURE, INC.
Date Issued
Job No.
Sheet No.
CITY
HAL
L /
PUBL
IC L
IBRA
RY P
ROJE
CTCI
TY O
F LA
GUN
A W
OO
DS24
264
El T
oro
Rd, L
agun
a W
oods
, CA
9263
7
8.03.2021
CLW-006
DN BY: AS, BP CK BY: JJ, JT
08.30.2021PLT DATE:
SDG PRJ # 20-105
PERM
IT S
ET
REVISIONSNo.
LI-1.2
WAT
ER U
SE C
ALCU
LATI
ON
S
TREE
SHRUBS
SHRUBS
SHRUBS
TREE
SHRUBS
SHRUBS
SHRUBS
SHRUBS
SHRUBS
SHRUBS
ZONE 1
ZONE 2
ZONE 3
ZONE 4
ZONE 5
ZONE 6
ZONE 7
ZONE 8
ZONE 9
ZONE 10
ZONE 11
0.5
0.2
0.2
0.2
0.5
0.2
0.2
0.2
0.2
0.2
0.2
BUBBLER
DRIPLINE
ROTATOR
DRIPLINE
BUBBLER
DRIPLINE
DRIPLINE
DRIPLINE
ROTATOR
ROTATOR
ROTATOR
77%
81%
76%
81%
77%
81%
81%
81%
76%
76%
76%
0.649
0.247
0.263
0.247
0.649
0.247
0.247
0.247
0.263
0.263
0.263
120 SQ-FT
922 SQ-FT
488 SQ-FT
195 SQ-FT
200 SQ-FT
228 SQ-FT
334 SQ-FT
264 SQ-FT
1,312 SQ-FT
1,313 SQ-FT
704 SQ-FT
77.88
227.74
128.35
48.17
129.80
56.32
82.50
65.21
345.06
345.32
185.15
2,318
6,778
3,820
1,434
3,863
1,676
2,455
1,941
10,277
10,278
5,510
0.326 6,080 SQ-FT6,080 SQ-FT 1,691.50
0.326
50,350
81,423
48.00 X
Date Issued 09.08.21
BID
SET
Date Issued 09.08.21Date Issued 09.08.21Date Issued 09.08.21
AUTOMATIC FLUSH VALVE
1
2
3
4
5
6
7
FINISH GRADEḀ3" BELOW TOP OF LIDIN PLANTING BED WITHMULCH, TYPICAL
1
VALVE BOX, PERSPECIFICATIONS
2
AUTOMATIC LINEFLUSHING VALVEPER LEGEND
3
PRC REDUCERADAPTER S X 1/2" FPT(SIZE AS REQ'D)
4
BRICK SUPPORTS(THREE, TYPICAL)
5
3/4" GRAVEL SUMP;1 CUBIC FOOT
6
PLUMBED TO PVCLATERAL OREXHAUST HEADER
7
9" MIN.
NOTESᴀA. INSTALL PER MANUFACTURE'S RECOMMENDATIONS.B. INSTALL AT LOWEST POINT(S) ON A SYSTEM.C. ALL VALVE BOXES TO INCLUDE 1/4" GALVANIZED STEEL WIRE MESH
AND FABRIC (FOR RODENT CONTROL) AND INCLUDE BOLTS ANDWASHERS (FOR BEEHIVE CONTROL).
1" MIN
4
obr
GARR
ICK
OLI
VER
C
HRIS
TOPH
ER B
ITTN
ER
AN
NEY
RO
SEN
THAL
-HAL
L
3817
Ray
Str
eet S
an D
iego
, Ca
9210
4e
in
fo@
obra
rchi
tect
ure.
com
w
obra
rchi
tect
ure.
com
t 6
19.5
64.7
586
f 6
19.5
68.3
636
OBRARCHITECTURE, INC. ALL RIGHTSRESERVED. THE ABOVE DRAWINGS, IDEAS,AND EMBODIED DESIGNS THEREIN ARE THEPROPERTY OF OBRARCHITECTURE, INC. ANDSHALL NOT BE COPIED, REPRODUCED,DISCLOSED TO OTHERS OR USED INCONNECTION WITH ANY WORK OTHER THANTHE SPECIFIED PROJECT FOR WHICH THEYHAVE BEEN PREPARED, IN WHOLE OR INPART, WITHOUT THE PRIOR WRITTENAUTHORIZATION OF OBRARCHITECTURE, INC.
Date Issued
Job No.
Sheet No.
CITY
HAL
L /
PUBL
IC L
IBRA
RY P
ROJE
CTCI
TY O
F LA
GUN
A W
OO
DS24
264
El T
oro
Rd, L
agun
a W
oods
, CA
9263
7
8.03.2021
CLW-006
DN BY: AS, BP CK BY: JJ, JT
08.30.2021PLT DATEᴀ
SDG PRJ # 20-105
PERM
IT S
ET
REVISIONSNo.
LI-2.0
IRRI
GATI
ON
DET
AILS
2Ԁ
A
12Ԁ
3Ԁ
A
FINISH GRADE IN TURF AREAS
POP-UP ROTOR HEAD AND NOZZLE
WAL OR CURB─
12" M
IN.
FINISH GRADE IN PLANTING AREAS
MULCH LAYER IN PLANTING AREAS
P.V.C. LATERAL (PER PLAN)
P.V.C. TEE OR ELL (SXSXT)
LEGENDᴀ
NOTESᴀ
POP-UP ROTOR/SPRAY HEAD
1
2
3
4
5
6
7
8
9
PVC STREET ELL (2 EACH)SIZE PER HEAD INLET
SCH.80 P.V.C. NIPPLE (2 EACH)SIZE PER HEAD INLET
2
1
1. ALL P.V.C. FITTINGS SHALL BE SCH.40 EXCEPT WHERE NOTED.
2. ALL SCH.80 P.V.C. THREADS SHALL BEWRAPPED WITH TEFLON TAPE. ORRECOMMENDED BY MANUFACTURER
3" SPRAY DISTANCE6" ROTOR SPRAY DISTANCE
7
9
8
6
5
4
3
1
1/2-INCH MALE NPT INLET (INCLUDED)
1/2-INCH 90-DEGREE ELBOW (INCLUDED)1/2-INCH PVC SCH 80 NIPPLE (INCLUDED)
LATERAL PIPE
FINISH GRADE
PVC SCH 40 TEE OR EL
4-INCH GRATE (INCLUDED)
DEEP ROOT WATERING SYSTEM
12-INCH SWING ASSEMBLY (INCLUDED)
OPTIONAL PEA GRAVEL OR SAND SOCKFOR SANDY SOILS
ROOT WATERING SYSTEM ASSEMBLY:INCLUDES BUBBLER WITH RISER, GRATE,SWING ASSEMBLY, 1/2" MALE NPT INLET,AND BASKET CANISTER. -SEE IRRIGATION LEGEND AND PLANSFOR MANUFACTURER/ MODEL
BUBBLER NOZZLE (INCLUDED)
NOTESᴀ1. SEE IRRIGATION PLANS FOR QUANTITY
OF ASSEMBLIES PER TREE (TYP.)2. DEPTH OF UNIT PER IRRIGATION
LEGEND3. MAINTAIN 2' MINIMUM CLEAR FROM
TRUNK OF TREE.
12
34
5
6
78
1
4-INCH BASKET WEAVE CANISTER(INCLUDED)
2
3
4
5
6
7
8
9
10
11
12
9
10
1112
2
SECTIONPLAN
1 2 3 4 5
9
6
10
11
12 13 1514
7 89 6 2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
VALVE BOX WITH COVER ASSPECIFIED IN THE IRRIGATION NOTESWATERPROOF CONNECTION,TYPICAL
VALVE ID TAG
30-INCH LINEAR LENGTH OF WIRE,COILED
PRESSURE REGULATING FILTER PERMANUFACTURER'S RECOMMENDATIONSPVC SCH 40 FEMALE ADAPTOR
LATERAL PIPE
REMOTE CONTROL VALVE PER IRRIGATIONLEGEND
PVC SCH 40 ELL
PVC SCH 80 NIPPLE (LENGTH AS REQUIRED)
PVC SCH 80 NIPPLE (2-INCH LENGTH, HIDDEN)AND PVC SCH 40 ELL)
PVC SCH 40 TEE OR ELL
PVC MAINLINE
3-INCH MINIMUM DEPTH OF 3/4-INCHWASHED GRAVEL
FINISH GRADE
TYPICAL DRIP CONTROL VALVE KIT
LEGENDᴀ
15
NOTEᴀ1. FOR RECYCLE WATER SYSTEM PROVIDE
'PURPLE' PVC, VALVE BOX AND TAG.
3
HUNTER DRIP INDICATOR
12
3
4
5
67
8
HUNTER ECOINDICATOR - ECOID
1
LATERAL PIPE PERPLAN
2
FTP CONNECTIONFROM LATERAL
3
4
FLEX TUBING; FLEXSGOR EQUAL
5
FINISH GRADE PERPLAN
6
ADJCENT MULCH IFAPPLICABLE
7
MARLEX STREETELBOW
8
4
SPIRAL BARB ELBOW
6
NOTESᴀ1. INSTALL PER MANUFACTURER'S
RECOMMENDATIONS.2. HUNTER ECO INDICATORḀ
WORKING PRESSURE: 15 PSI -50 PSI.
3. CAN BE INSTALLED WITH RIGIDPVC SYSTEM, PE TUBING, OREMITTER LINE.
4. VISUAL: 6" YELLOW POP-UPSTEM. STEM RETRACTS WHENPRESSURE DROPS BELOW 10PSI.
LEGENDᴀ
ELEVATION
5
EXHAUSTHEADER
SUPPLYHEADER.
CHECK LONGESTLATERAL AGAINSTMAXIMUM LENGTHOF SINGLE LATERALTABLE.
TOTAL THECOMBINED LENGTHOF THESELATERALS ANDCOMPARE ITAGAINST THEMAXIMUM LENGTHOF SINGLELATERAL TABLE.
BRANCHING OUT LATERALS
JOINING LATERALSAREAS: TRIANGULARIRREGULAR
PVC MAINLINE.
DRIPLINE SPACING ASNOTED.
CENTER FEED EXAMPLEEND FEED EXAMPLE
AUTOMATIC LINE FLUSHINGVALVE PLUMBED TO PVC ORPOLY LINE, AS NOTED.
TYPICAL TECHLINE TUBINGLATERALS WITH EMITTERSPACING AS NOTED. TIEDOWN STAKE AT ALL TEES,ELLS, AND AT 5' O.C. AT CLAY,4' O.C. AT LOAM, OR 3' O.C. ATSAND.
DRIP VALVE / FILTER /REGULATOR.
12" POLYETHYLENE OR PVC
HEADER.
TYPICAL OFFSET2" FROMHARDSCAPE, 4"FROM PLANTEDAREA.
TYPICAL START CONNECTIONSXSXT TEE W/ TECHLINE MALEADAPTER.
TYPICAL LATERALPIPE FROM VALVEASSEMBLY, SIZE PERPLANS.
TYPICAL OFFSET 2" FROMHARDSCAPE, 4" FROM
PLANTED AREA.
WATER SOURCE: DRIP VALVE ORLATERAL FROM VALVE.
TYPICAL SUPPLY HEADER.
TYPICAL TECHLINE DRIPPER LINE TUBING TO BE BURIED 1" BELOW FINISHGRADE IN LANDSCAPE AREASTYPICAL PVC OR POLY SUPPLY OR EXHAUST HEADERTO BE BURRIED MIN 12" BELOW GRADE.
AUTOMATIC LINE FLUSH VALVEPLUMBED TO PVC OR POLY.
LAYOUTISLAND
IRREGULAR AREAS: ODD CURVES SLOPE FEED LAYOUT
54" MAX.ELEVATIONCHANGE
MANUAL LINE FLUSHING VALVE.TECHLINE CV LATERAL TUBING.LATERALS PARALLEL TO THECONTOURS OF THE SLOPE.
PVC EXHAUST HEADER.
TOE OFSLOPE.
TOP OF SLOPE.PVC SUPPLYHEADER.
REMOTE CONTROLVALVE ASSEMBLY.
BOTTOM 13 OF SLOPEᴀCONVENTIONAL SPACINGPLUS 25%
TOP 13 OFSLOPEᴀCONVENTIONALSPACING.
TECHLINE CV MAXIMUM LENGTH OF SINGLE LATERAL (FEET)
TECHLINE CV FLOW PER 100 FEET
TYPICAL DRIPLINE REQUIREMENTS
DRIP INDICATORPOP-UP
DRIP INDICATORPOP-UP
DRIP INDICATOR POP-UP
6
ALL MANIFOLD PIPING AND ISOLATION VALVES TO BE2" MIN. INTO EACH CONTROL VALVE AND 1" TO EACH Q.C.
NOTESᴀ1) EACH MANIFOLD SHALL HAVE A MAXIMUM OF
15' SEPARATION.2) ALL MANIFOLDS ARE TO BE INSTALLED IN
PLANTER AREAS WHENEVER POSSIBLE.
A-1
12Ԁ
A-2
1'-6" 1'-6"
A-3
GENERAL NOTEᴀ
1'-6"
BV
1'-6"
BV
1'-6"
QC
MANIFOLD CONFIGURATION
EDGE OF SIDEWALK OR PAVING1
6
5 4
3
2
PRESSURE SUPPLY LINE(SEE PLAN FOR SIZE)
BALL VALVES (SEEIRRIGATION LEGEND)
QUICK COUPLER (SEEIRRIGATION LEGEND)
HEAT BRAND ALL VALVES
1
2
3
4
ELECTRIC CONTROL VALVE
MANIFOLD PIPE-SAME SIZE AS PRESSURE SUPPLYLINE LOCATED UNDERNEATH VALVE BOXES. ALLMAINLINE FITTINGS TO BE SCH. 80 PVC
5
6
LEGENDᴀ
7
Date Issued 09.08.21
BID
SET
Date Issued 09.08.21Date Issued 09.08.21Date Issued 09.08.21
obr
GARR
ICK
OLI
VER
C
HRIS
TOPH
ER B
ITTN
ER
AN
NEY
RO
SEN
THAL
-HAL
L
3817
Ray
Str
eet S
an D
iego
, Ca
9210
4e
in
fo@
obra
rchi
tect
ure.
com
w
obra
rchi
tect
ure.
com
t 6
19.5
64.7
586
f 6
19.5
68.3
636
OBRARCHITECTURE, INC. ALL RIGHTSRESERVED. THE ABOVE DRAWINGS, IDEAS,AND EMBODIED DESIGNS THEREIN ARE THEPROPERTY OF OBRARCHITECTURE, INC. ANDSHALL NOT BE COPIED, REPRODUCED,DISCLOSED TO OTHERS OR USED INCONNECTION WITH ANY WORK OTHER THANTHE SPECIFIED PROJECT FOR WHICH THEYHAVE BEEN PREPARED, IN WHOLE OR INPART, WITHOUT THE PRIOR WRITTENAUTHORIZATION OF OBRARCHITECTURE, INC.
Date Issued
Job No.
Sheet No.
CITY
HAL
L /
PUBL
IC L
IBRA
RY P
ROJE
CTCI
TY O
F LA
GUN
A W
OO
DS24
264
El T
oro
Rd, L
agun
a W
oods
, CA
9263
7
8.03.2021
CLW-006
DN BY: AS, BP CK BY: JJ, JT
08.30.2021PLT DATE:
SDG PRJ # 20-105
PERM
IT S
ET
REVISIONSNo.
LI-2.1
IRRI
GATI
ON
DET
AILS
18"
12"
17
1
2
43
5
FLOW
151614
13
11
11
12
6 7 8
10
9
SCH.40 P.V.C. TEE MAINLINE13
UNMORTARED BRICK FOUNDATION17
16
14
15
(TXS)
P.V.C LATERAL LINE PER LEGEND.
SCH.80 P.V.C. NIPPLE
SCH.40 P.V.C. ELL (SXS)
SCH.80 FEMALE ADAPTER
PV.C. PIPE
8
10
12
11
9
7
6
5
SCH.80 P.V.C. NIPPLE
P.V.C. MALE ADAPTER
4
3
21
REMOTE CONTROL VALVE
LEGEND:
NOTES:
1. ALL THREADED PIPE CONNECTIONS WILL BESEALED WITH OVERLAPPING WRAPS OF TEFLONTAPE AS REQUIRED TO PREVENT LEAKAGE.2. WIRE CONNECTORS WILL BE K.B."ONE-STEP"PRE-FILLED TAN) OR EQUAL.3. DIRECT BURIAL COMMON AND CONTROLWIRES WILL BE COILED TO PROVIDE 12"EXPANSION COILS INSIDE VALVE BOX.
12" RECTANGULAR PLASTIC VALVEBOX (CARSON) WITH LOCKING LID,CONTROLLER AND VALVENUMBER HEAT BRANDED INTO TOP
WATERPROOF WIRECONNECTORS PER NOTESREMOTE CONTROL ELECTRICVALVE PER LEGEND
SCH. 80 P.V.C. UNION (TXT) O-RINGTYPE LASCO OR EQUAL
FINISH GRADE - ALLOW 2" FORMULCH IN SHRUB BEDS SET FLUSHIN TURF
PRESSURIZED P.V.C. MAINLINE(SXSXS) PER LEGEND24 VOLT DIRECT BURIAL WIRESFROM CONTROLLER PER LEGEND.1 CUBIC FOOT PEA GRAVEL MIN.SUPPORTING VALVE BOX
ALLOW 2"MIN.CLEARANCE
2" MIN
1
12" (
305m
m) M
IN.
QUICK COUPLER
1 2LEGEND:
310" (254mm) ROUND PLASTICVALVE BOX WITH LOCKINGCOVER AND Q.C. LABELEDTOP.
1
QUICK COUPLER VALVE WITHACME THREADS PER PLANS.
2
FINISH GRADE. ALLOW 2"(50mm) DEPTH FOR TOPMULCH OR 1" DEPTH ATLAWN
34
ONE CUBIC FOOT (.03m ) PEAGRAVEL.
4
NOTES:1. ALL P.V.C. FITTINGS SHALL BE SCH. 40
EXCEPT WHERE NOTED.2. ALL SCH.80 P.V.C. THREADS SHALL BE
WRAPPED WITH TEFLON TAPE.3. QUICK COUPLER VALVES SHALL BE OF
A TYPE APPROVED FOR RECYCLEDWATER.
5
56
P.V.C. ELL (TXT).67
SCH.40 P.V.C. MAINLINE.78
88
MARLEX STREET ELLS (2)REQUIRED PER QUICKCOUPLER.
5
SCH.80 P.V.C. NIPPLE.
9
SCH.40 P.V.C. TEE (SXSXT).9
2
18"
2"
BALL / GATE ISOLATION VALVE
7
5
6
4
10
28
29
1 THREADED PVC SCH 80 NIPPLES(NO CLOSE NIPPLES TYP.)
PRESSURIZED PVC MAINLINE
PVC FEMALE SXT ADAPTER
PVC SCH 80 UNION - EITHER SIDE
VALVE AS SPECIFIED ON PLANSPOSITION VALVE IN BOX SO THATHANDLE IS FREE TO OPERATE
10" ROUND PLASTIC VALVE BOXFOR 2" VALVE AND SMALLERRECTANGULAR PLASTIC VALVE
BOX FOR 2 1/2" VALVE ANDLARGER (PER SPECIFICATIONS)INSTALL 2" ABOVE FINISHEDGRADE IN SHRUB BED; 1/2"ABOVE IN LAWN AREAS
FINISHED GRADE
PVC SCH 40 45DEG. FITTING
PEA GRAVEL 1/2" DIAMETER(APPROX. 1 CU. FT.)
UNMORTARED BRICKFOUNDATION
2
3
4
5
6
7
8
9
10
LEGEND:
3
FINISH SURFACE PVC PIPE
MASTER VALVE
12
1
2
3
4
5
6
7
8
9
10
11
12
1
3
4
5
6
7
8
9
10
211
CONNECT WIRES TO VALVE USINGWATER TIGHT CONNECTORS
MASTER VALVE PER IRRIGATIONEQUIPMENT LEGEND
RECTANGULAR CONCRETE VALVEBOX W/ LOCKING HINGED CAST IRONLID. PAINT LID PURPLE FORRECYCLED WATER USE
PVC SCH. 40 MALE ADAPTER(2 REQUIRED)
PRESSURE SUPPLY LINE,ALIGN WITHFLOW SENSOR (SEE PLAN FOR SIZE)SCH. 80 PVC UNION O-RING TYPELASCO OR EQUAL
1-1/4" SCH. 40 WIRE CONDUIT WITHSWEEP FOR MASTER VALVE WIRES(TO FLOW SENSOR)
3/4" GRAVEL SUMP IN, UNDER, ANDAROUND VALVE BOX FILL TO TOP OFVALVE BOXES
SLIP X SLIP 45 DEGREE ELL(2 REQUIRED)
USE 1/2" PVC SCRAP TO WRAP 12" OFADDITIONAL WIRE BEFORECONNECTING
LEGEND:
4
PEA GRAVEL DRAIN SUMP30" MIN. DIA. x 6" MIN. DEEP
RED BLACK
TWO (2) CONDUCTOR SHIELDED CABLECONNECTION TO TRANSMITTER
BLACK RED
FLOW SENSOR
9
8 3
2
1
4
5
67
10
11
12
1 1" IN TURF AREAS 2"IN SHRUB AREAS
FINISH GRADE
EXTENSION
JUMBO BOX
5 x PIPE DIA.
EXTENSION
FLOW SENSOR
WATERPROOFCONNECTIONS
JUMBO PLASTICVALVE BOX W/ 2-6"EXTENSIONS ANDLOCKING COVER,AMETEK OR EQUAL
10 x PIPE DIA.
MAINLINE
BRICKREINFORCEMENT,TYPICAL
2
3
4
5
6
7
8
9
10
11
12
5NO SCALE
WIRE BUNDLE JUNCTION / PULL BOX / STUB-OUT
WIRES TO CONTROLLER
1
10x15" STANDARD VALVE BOX, HEAT BRAND'J BOX' ON LID WITH 2" HIGH LETTERS
SPARE WIRES THAT ARE TO TERMINATE ATTHIS BOX: COIL 30" LENGTH AND I.D. TAG.
LOOP, BUNDLE, AND LABEL SPARE WIRESTHAT ARE TO CONTINUE, AS OCCURS
1/2 " GALVANIZED WIRE CLOTH/ GOPHERPROTECTION WRAP - WRAP 6" UP SIDES
(2) 6x2x12 CONCRETE BLOCK CAPS, ONE ONEACH SIDE OF BOX
IRRIGATION MAINLINE PER PLANS.PROVIDE SOLVENT WELD CAP AND TURNMAINLINE UPWARD INTO BOX WHEREINDICATED TO STUB-OUT FOR FUTURE USE
SOIL SUBGRADE
1
2
3
4
5
6
NOTE: TOP OF VALVE BOX SHALL BE SET 2"ABOVE GRADE AT SHRUB/ PLANTING AREASAND FLUSH TO GRADE AT LAWN AREAS
7
7
4
3
5
7
SEE NOTES
2
6LEGEND:
6S2-LA6-45
NOTES:
2
112
6
4
5
87
4
3
5
7
3" MIN.
6" MIN.
6"
6" M
IN.6
18"+ DIAMETEROF PIPE
1" M
IN.
6" M
IN.
3
12"
8
18" M
IN.
6" MIN.
LEGEND:
MAINLINE/DIRECT BURIAL CONTROL WIRE
IMPORTED TOPSOIL OR AMMENDEDNATIVE SOILFINISHED GRADENATIVE SOIL FREE OF ROCKS ANDDEBRIS 3" OR GREATERTRENCH MARKER
SAND BEDDING MATERIAL
IRRIGATION MAINLINE
DIRECT BURIAL CONTROL WIRESIRRIGATION LATERAL LINE
1. TRENCH MARKER SHALL BE A 3" WIDECONTINUOUS METALLIC PLASTIC STRIPABOVE THE MAINLINE AND DIRECT BURIALCONTROL WIRES.2. ALL PIPE AND CONTROL WIRE UNDERPAVEMENT SHALL BE INSTALLED IN A P.V.C.SLEEVE PER THE IRRIGATIONSPECIFICATIONS.3. BACKFILL MATERIAL SHALL BE COMPACTEDTO A RELATIVE COMPACTION OF 90% MIN.
4"
9 IN LINE DRIP TUBING
9
7
WATERPROOF WIRE CONNECTOR
NOTES:1. WIRE CONNECTOR SHALL BE A 3M DBY-6
DIRECT BURY SPLICE KIT (U.L.APPROVED).
2. KIT SHALL INCLUDE A SCOTCHLOK YSPRING CONNECTOR, A POLYPROPYLENETUBE AND A WATERPROOF SEALING GEL.TUBE SHALL BE SUPPLIED PREFILLEDWITH GEL.
3. DIRECT BURY SPLICE KIT SHALL BE USEDTO ELECTRICALLY CONNECT TWO (2) -THREE (3) #14 OR TWO (2) #12PRE-STRIPPED COPPER WIRES. LARGERWIRES OR GREATER QUANTITIES OFWIRES SHALL REQUIRE A LARGERAPPROVED WIRE CONNECTION (3M -DBR-6).
1
2
3
4
5
6
1 LOW VOLTAGE WIRES, THREE (3) MAXIMUM.
WIRES PASS THROUGH GROOVES IN TUBELID TO ALLOW LID TO CLOSE.
CLOSE TUBE LID AFTER WIRE IS INSERTEDINTO TUBE.
POLY TUBE PRE-FILLED WITH WATERPROOFGEL.
LOCK TABS PREVENT WIRE REMOVAL ONCECONNECTOR IS INSERTED.
SCOTCHLOK ELECTRICAL SPRINGCONNECTOR. WIRES SHALL BEPRE-STRIPPED OF 1/2" OF THE INSULATIONPRIOR TO INSERTION INTO THECONNECTIOR. TWIST CONNECTOR ONTOWIRES TO SEAT FIRMLY.
SCOTCHLOK CONNECTOR AND WIRESINSERTED INTO TUBE UNTIL THECONNECTOR PASSES LOCK TABS.
2
3
4
5
6
LEGEND:
9
NOTE:
UNDISTURBED SOIL
LATERAL LINES PER PLAN
IRRIGATION MAINLINE PER PLAN
DIRECT BURIAL CONTROL WIRES
FINISHED GRADE
PAVING PER PLAN
MARKING STRIP
SAND BEDDING MATERIAL
CLEAN COMPACTED BACKFILL
6" M
IN
VAR
IES
1. ALL PIPE AND CONTROL WIRE UNDERPAVEMENT SHALL BE INSTALLED IN AP.V.C. SLEEVE, 2X THE DIA. OF PIPE ORBUNDLE MIN.
2. BACKFILL MATERIAL SHALL BECOMPACTED PER SOILS REPORT.
3. PRESSURE MAINLINE SHALL BE INSTALLEDON A 6" SAND BED AND COVERED BY 6" OFSAND PRIOR TO ANY OTHER BACKFILLMATERIAL.
108 1 2
3
4
5
6
7
9
10
A
BD
C
DIMENSION - PED.2" - 12" SIZEDIM - VEHICULAR2 - 12" SIZE
A30"
36"
B24"
30"
C24"
30"
D6"
6"
SCH. 40 PVC SLEEVE 2x PIPE SIZEDIAMETER MIN.(EXTEND 12" MIN. BEYOND PAVING)
SLEEVING UNDER PAVEMENT
1
2
3
4
56
7
8
9
10
NOTE:
8
Date Issued 09.08.21
BID
SET
Date Issued 09.08.21Date Issued 09.08.21Date Issued 09.08.21
TREES BOTANICAL NAME COMMON NAME CONT REMARKS
ARBUTUS UNEDO `COMPACTA` MARINA STRAWBERRY TREE MULTI-TRUNK 24" BOX
CERCIDIUM MICROPHYLLUM SMALLLEAF PALO VERDE 36" BOX
EXISTING TREE PROTECT IN PLACE 12` BTH
SYAGRUS ROMANZOFFIANA QUEEN PALM 24" BOX
SHRUBS BOTANICAL NAME COMMON NAME CONT REMARKS
AGAVE ATTENUATA FOXTAIL AGAVE 5 GALLON
AGAVE X `MOONGLOW` MANFREDA 5 GALLON
AGAVE X `MOONSHINE` MOONSHINE AGAVE 5 GALLON
ALYOGYNE HUEGELII `SANTA CRUZ` SANTA CRUZ BLUE HIBISCUS 5 GALLON
CISTUS X PULVERULENTUS `SUNSET` SUNSET ROCKROSE 5 GALLON
DRACAENA MARGINATA RED EDGED DRACAENA 5 GALLON
ECHEVERIA X `AFTERGLOW` AFTERGLOW ECHEVERIA 1 GALLON
HESPERALOE PARVIFLORA RED YUCCA 5 GALLON
PRUNUS CAROLINIANA `MONUS` BRIGHT `N TIGHT CAROLINA CHERRY LAUREL 15 GALLON
RHAPHIOLEPIS INDICA INDIAN HAWTHORN 5 GALLON
SENECIO DECARYI MADAGASCAR SENECIO 5 GALLON
WESTRINGIA FRUTICOSA COAST ROSEMARY 5 GALLON
SHRUB AREAS BOTANICAL NAME COMMON NAME CONT SPACING REMARKS
CAREX PRAEGRACILIS CALIFORNIA FIELD SEDGE 1 GAL 6" o.c.
CHRYSACTINIA MEXICANA DAMIANITA 1 GAL 18" o.c.
CLIVIA MINIATA `BELGIAN HYBRID ORANGE` BELGIAN HYBRID ORANGE BUSH LILLY 5 GAL 18" o.c.
DIANELLA TASMANICA `VARIEGATA` VARIEGATED FLAX LILY 5 GAL 24" o.c.
SESLERIA AUTUMNALIS AUTUMN MOOR GRASS 1 GAL 15" o.c.
PLANTING LEGEND:DETAIL
REFERENCE
1,4/LP-2.0
4,5/LP-2.0
DETAILREFERENCE
1,4/LP-2.0
1,4/LP-2.0
3/LP-2.0
3/LP-2.0
3/LP-2.0
3/LP-2.0
3/LP-2.0
3/LP-2.0
3/LP-2.0
3/LP-2.0
3/LP-2.0
3/LP-2.0
3/LP-2.0
3/LP-2.0
2/LP-2.0
2/LP-2.0
DETAILREFERENCE
DEEP ROOT ROOT BARRIER
2/LP-2.0
WATERUSE
LOW
LOW TOMEDIUM
MODERATE/MEDIUM
LOW
LOW
VERYLOW
LOW
LOW
LOW
LOW
WATERUSE
VERYLOW
LOW
MODERATE/MEDIUM
LOW
LOW
LOW
LOW
MODERATE/MEDIUM
2/LP-2.0 LOW
2/LP-2.0 MODERATE/MEDIUM
REPAIR EXISTING PLANT MATERIALIN KIND WITH MIN. 5 GALLON SHRUBS
RHUS LANCEA AFRICAN SUMAC obr
GARR
ICK
OLI
VER
C
HRIS
TOPH
ER B
ITTN
ER
AN
NEY
RO
SEN
THAL
-HAL
L
3817
Ray
Str
eet S
an D
iego
, Ca
9210
4e
in
fo@
obra
rchi
tect
ure.
com
w
obra
rchi
tect
ure.
com
t 6
19.5
64.7
586
f 6
19.5
68.3
636
OBRARCHITECTURE, INC. ALL RIGHTSRESERVED. THE ABOVE DRAWINGS, IDEAS,AND EMBODIED DESIGNS THEREIN ARE THEPROPERTY OF OBRARCHITECTURE, INC. ANDSHALL NOT BE COPIED, REPRODUCED,DISCLOSED TO OTHERS OR USED INCONNECTION WITH ANY WORK OTHER THANTHE SPECIFIED PROJECT FOR WHICH THEYHAVE BEEN PREPARED, IN WHOLE OR INPART, WITHOUT THE PRIOR WRITTENAUTHORIZATION OF OBRARCHITECTURE, INC.
Date Issued
Job No.
Sheet No.
CITY
HAL
L /
PUBL
IC L
IBRA
RY P
ROJE
CTCI
TY O
F LA
GUN
A W
OO
DS24
264
El T
oro
Rd, L
agun
a W
oods
, CA
9263
7
8.03.2021
CLW-006
DN BY: AS, BP CK BY: JJ, JT
08.30.2021PLT DATE:
SDG PRJ # 20-105
PERM
IT S
ET
REVISIONSNo.
LP-1.0
1. CONTRACTOR SHALL REVIEW PLANTING SPECIFICATIONS BEFORE BEGINNINGWORK.
2. CONTRACTOR SHALL REVIEW PLANTING INSTALLATION DETAILS PRIOR TOBEGINNING WORK.
3. CONTRACTOR SHALL VISIT SITE AND BECOME FAMILIAR WITH CONDITIONSUNDER WHICH WORK SHALL BE DONE PRIOR TO BIDDING.
4. ALL WORK WILL BE IN ACCORDANCE WITH THE REQUIREMENTS OF THE CITYOF LAGUNA WOODS AND THE TECHNICAL SPECIFICATIONS FOR THE PROJECT.
5. CONTRACTOR SHALL NOTIFY CITY ENGINEER OF ANY DISCREPANCIES IN THEEXISTING CONDITIONS OR WITHIN THE PLANS PRIOR TO BEGINNING WORK.
6. FINISHED GRADES SHALL BE SMOOTHED TO ELIMINATE PUDDLING ORSTANDING WATER. CONTRACTOR SHALL MAINTAIN A MINIMUM 2% DRAINAGEAWAY FROM BUILDINGS AND PAVING INTO DRAINAGE STRUCTURES OR TOSTREET (SEE ENGINEERS GRADING AND DRAINAGE PLAN). CONTRACTORSHALL NOTIFY RESIDENT ENGINEER IMMEDIATELY OF ANY CONFLICTS INMAINTAINING DRAINAGE.
7. CITY ENGINEER SHALL APPROVE ALL FINISH GRADING PRIOR TO PLACEMENTOF ANY PLANT MATERIAL.
8. CONTRACTOR SHALL IMMEDIATELY, UPON THE AWARD OF THE CONTRACT,ORDER, LOCATE AND PURCHASE (OR HAVE HELD) ALL PLANT MATERIALREQUIRED BY THESE PLANS AND SPECIFICATIONS.
9. CONTRACTOR SHALL NOTIFY CITY ENGINEER FOR OBSERVATION AT THEFOLLOWING TIMES:
--MAINLINE - PRIOR TO BACKFILL AND PRESSURE TEST--LATERAL LINES - PRIOR TO BACKFILL--CONTROL WIRES - PRIOR TO BACKFILL--TREE LOCATIONS - PRIOR TO PLANTING--IRRIGATION COVERAGE - PRIOR TO PLANT PLACEMENT--PLANT APPROVAL AND SPOTTING PRIOR TO PLANTING--PRE-MAINTENANCE APPROVAL--POST-MAINTENANCE/FINAL APPROVAL.
10. THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR ANY REPAIRS MADENECESSARY THROUGH THE ACTIONS OR NEGLIGENCE OF HIS CREW.
11. SOIL AMENDMENTS SPECIFIED ARE FOR BIDDING PURPOSES ONLY. ACTUALTYPES AND QUANTITIES WILL BE BASED ON SOIL ANALYSIS PROVIDED BYCONTRACTOR. AFTER ROUGH GRADING, SOIL SAMPLES SHALL BE TAKENFROM ENOUGH LOCATIONS IN DIFFERENT AREAS OF THE SITE TO REPRESENTAN ADEQUATE CROSS SECTION OF CONDITIONS. TEST SHALL INCLUDE TESTSFOR SOIL FERTILITY, AGRICULTURAL SUITABILITY ORGANIC CONTENT N, P, K;PH; EC; SOIL TEXTURE; AND RECOMMENDATIONS FOR AMENDMENTS,LEACHING, AND MAINTENANCE FERTILIZATION. CONTRACTOR SHALL FURNISHRESIDENT ENGINEER WITH A COPY OF TEST RESULTS AND RECEIVE WRITTENAPPROVAL FOR AMENDMENTS/SOIL PREPARATION PRIOR TO INSTALLATION.
BID MIX FOR TURF AND SHRUB AREAS:SOIL AMENDMENTS BID MIX SHALL BE THE FOLLOWING PER 1000 SQUARE
FEET: - 4 CU. YDS. NITROGEN STABILIZED ORGANIC AMENDMENT 'KELLOG
NITRO MULCH' - 20 LBS. GRO-POWER PLUS - 100 LBS. GYPSUM
"SOIL PREP" TO BE MIXED INTO THE TOP 6" OF SOIL THROUGHOUT THE SITE EXCEPT ON SLOPES GREATER THAN 3:1.
BID MIX FOR SHRUB BACKFILL:PLANTING AND BACKFILL MIX FOR PLANT PITS AND TABLETS SHALL BE AS
FOLLOWS PER CUBIC YARD: - 70% OF NATIVE SOIL - 30% NITROGEN STABILIZED ORGANIC AMENDMENT - 16 LBS GRO-POWER PLUS - 2 LBS. FERROUS SULFATETHOROUGHLY BLEND THE ABOVE AT A CENTRAL ON-SITE LOCATION
PRIOR TO USE. THE FERROUS SULFATE SHOULD NOT CONTACT PAVING SURFACES AS STAINING WILL RESULT.
12. SHRUB AND GROUNDCOVER MASS QUANTITIES ARE SHOWN ON PLANS.UNDERPLANT ALL TREES WITH THE ADJACENT SHRUB AND/ ORGROUNDCOVER AS INDICATED BY THE PLANS. PLANTS SHALL BE INSTALLEDWITH TRIANGULAR SPACING. PLANT GROUNDCOVERS TO WITHIN 12" OFTREE OR SHRUB STEMS.
13. PLANT SYMBOLS TAKE PRECEDENCE OVER PLANT QUANTITIES SPECIFIED.WHERE SHRUB SYMBOLS ARE MASSED, CONTRACTOR SHALL MAINTAIN ACONSISTENT ON CENTER , TRIANGULAR SPACING AS SPECIFIED IN LEGEND.CONTRACTOR SHALL VERIFY PLANT TOTALS FOR BID PURPOSES.
14. ALL ROCKS AND DEBRIS TWO INCH (2") AND LARGER SHALL BE REMOVEDFROM PLANTING AREAS AND THEN FROM THE SITE TO A LEGAL SITE OFDISPOSAL. WHERE THE GRASS IS TO BE LOCATED, ALL ROCKS AND DEBRISONE INCH (1") AND LARGER SHALL BE REMOVED FROM THE SITE TO A LEGALSITE OF DISPOSAL.
15. PRIOR TO BEGINNING THE PLANTING OPERATION, IRRIGATE ALL PLANTINGAREAS NORMALLY FOR TWO WEEKS TO GERMINATE WEEDS. APPLY CONTACTORGANIC HERBICIDE TO WEEDS ONLY. REPEAT THE PROCESS IF WEEDSPERSIST.
16. PERCOLATION TEST SHALL BE CONDUCTED IN ACCORDANCE WITH THELANDSCAPE SPECIFICATIONS.
17. PRIOR TO PLANTING, IRRIGATION SYSTEM SHALL BE FULLY OPERATIONALAND ALL PLANTING AREAS SHALL BE THOROUGHLY WATERED.
18. PLANT MATERIAL MAY BE REJECTED AT ANY TIME BY CITY ENGINEER DUE TOCONDITION, FORM OR DAMAGE BEFORE OR AFTER PLANTING.
19. ALL TREES WITHIN 5' OR LESS OF HARDSCAPE SHALL BE INSTALLED WITH AROOT BARRIER. ROOT BARRIER SHALL BE INSTALLED PARALLEL TOHARDSCAPE SURFACE OR AS INDICATED ON PLAN. ROOT BARRIER TO BEMANUFACTURED BY "DEEPROOT" OR "BIO-BARRIER" OR EQUIVALENT.
20. PLANTING TABLETS SHALL BE GRO-POWER PLANTING TABLETS 12-8-8 (12MONTH SLOW RELEASE FORMULATION).
21. 1 GALLON GROUND COVER MATERIALS SHALL BE PLANTED TO WITHIN 12" OFADJACENT SHRUB STEMS.
13. ALL PLANTING BEDS SHALL HAVE 3" (THREE INCH) THICK TYPE 9 MULCHLAYER. PROVIDE 'TRAIL MULCH' OR 'LANDSCAPE MULCH' BY EL CORAZONCOMPOST FACILITY (760-439-9920) OR APPROVED EQUAL. RATES ASSPECIFIED ON PLANS, FREE OF STICKS, STONES, CLAY OR OTHER FOREIGNMATERIAL. CONTRACTOR SHALL SUBMIT SAMPLE TO CITY ENGINEER FORAPPROVAL PRIOR TO INSTALLATION.
23. ALL PLANTING SHALL BE GUARANTEED THROUGH THE ESTABLISHMENTPERIOD (SEE PLANTING SPECIFICATIONS). ESTABLISHMENT PERIOD SHALL BE90 DAYS. TREES AND SHRUBS SHALL BE GUARANTEED FOR A PERIOD OF ONEYEAR, BEGINNING FROM THE DATE OF THE FINAL ACCEPTANCE OF THEESTABLISHMENT PERIOD.
24. CONTRACTOR IS RESPONSIBLE FOR MAINTAINING ALL AREAS IN A WEED ANDDEBRIS-FREE CONDITION THROUGHOUT THE ESTABLISHMENT PERIOD.
25. COORDINATE PLACEMENT OF TREES WITH SITE LIGHTING. CANOPY OF TREEAT ULTIMATE SIZE SHALL NOT BE PLACED SO AS TO CONFLICT WITH LIGHTINGTHROW ALONG WALKWAYS.
26. PLANT MATERIAL SHALL BE GROWN UNDER CLIMATIC CONDITIONS SIMILARTO THOSE OF THE PROJECT SITE.
27. THE CONTRACTOR SHALL BID THE FOLLOWING PLANT MATERIAL IN ADDITIONTO THE QUANTITIES LISTED IN THE PLANT LEGEND OR SHOWN ON THE PLAN:
-(2) 15 GAL SHRUBS-(10) 5 GAL SHRUBS-(20) 1 GAL SHRUBS/GROUND COVER
28. CONTRACTOR SHALL INCREASE SOIL LEVEL IN ALL EXISTING PLANTERS TOREMAIN. FINISHED GRADE SHALL BE 4" BELOW CONCRETE CAP
29. CONTRACTOR TO STAKE TREES WITH 2-3 STAKES AND SIX TREE TIES(RUBBER CINCH TIES - NO WIRE). USE TRIPLE STAKING WITH 3” DIAMETERSTAKES IN HIGH WIND AREAS.
.
PLANTING NOTES:
STATEMENT OF RESPONSIBILITY: "I HAVE COMPLIED WITH THE CRITERIA OF THE WATEREFFICIENT LANDSCAPE ORDINANCE AND APPLIED THEM FOR THE EFFICIENT USE OF WATERIN THE LANDSCAPE DESIGN PLAN."
PLAN
TIN
G LE
GEN
D &
NO
TES
R1 - 8.30.2021
Date Issued 09.08.21
BID
SET
Date Issued 09.08.21Date Issued 09.08.21Date Issued 09.08.21
EL T
OR
O R
D.
WILLOW TREE CENTER ACCESS ROAD
UP
863 SFLIBRARY
131 SFOFFICE
80 SFRESTROOM87 SF
STORAGE
573 SF
OUTDOOR ACTIVITYSPACE
EXISTING CITYHALL BLDG.
PROPOSEDLIBRARY
BLDG.
obr
GARR
ICK
OLI
VER
C
HRIS
TOPH
ER B
ITTN
ER
AN
NEY
RO
SEN
THAL
-HAL
L
3817
Ray
Str
eet S
an D
iego
, Ca
9210
4e
in
fo@
obra
rchi
tect
ure.
com
w
obra
rchi
tect
ure.
com
t 6
19.5
64.7
586
f 6
19.5
68.3
636
OBRARCHITECTURE, INC. ALL RIGHTSRESERVED. THE ABOVE DRAWINGS, IDEAS,AND EMBODIED DESIGNS THEREIN ARE THEPROPERTY OF OBRARCHITECTURE, INC. ANDSHALL NOT BE COPIED, REPRODUCED,DISCLOSED TO OTHERS OR USED INCONNECTION WITH ANY WORK OTHER THANTHE SPECIFIED PROJECT FOR WHICH THEYHAVE BEEN PREPARED, IN WHOLE OR INPART, WITHOUT THE PRIOR WRITTENAUTHORIZATION OF OBRARCHITECTURE, INC.
Date Issued
Job No.
Sheet No.
CITY
HAL
L /
PUBL
IC L
IBRA
RY P
ROJE
CTCI
TY O
F LA
GUN
A W
OO
DS24
264
El T
oro
Rd, L
agun
a W
oods
, CA
9263
7
8.03.2021
CLW-006
DN BY: AS, BP CK BY: JJ, JT
08.30.2021PLT DATE:
SDG PRJ # 20-105
PERM
IT S
ET
REVISIONSNo.
LP-1.15 10 20
1" = 10'-0"SCALE :
0
NORTH
1. SEE SHEET LP-1.0 FOR PLANTING LEGEND AND NOTES2. SEE SHEETS LP-2.0 - LP-2.1 FOR PLANTING DETAILS
GENERAL NOTES:
CONTRACTOR TO REPAIR ALLEXISTING PLANTING DAMAGED BY
NEW WATER LINE INSTALLATION.PLANTS TO BE REPLACED WITHMINIMUM 5 GALLON PLANTS TO
MATCH EXISTING PLANTING
PLAN
TIN
G PL
AN
R1 - 8.30.2021
Date Issued 09.08.21
BID
SET
Date Issued 09.08.21Date Issued 09.08.21Date Issued 09.08.21
PREVAILINGWIND
2"
(1M
) 3' -
0" M
IN.
2X ROOT BALLNOTE: MAINTAIN A 36'' CIRCLE OF MULCH AROUNDALL TREES - NO TURF SHALL OCCUR WITHIN THISAREA.
TREE PLANTING
1
2
3
4
5 6
7
8
.
10
PLANTING BACKFILL PER NOTES ANDSPECIFICATIONS.
1
ROUGHEN SIDES AND BOTTOM OF PIT.2
FINISHED GRADE OF LAWN.3
"CINCH-TIE" MANUF. BY V.I.T. COMPANY,INC. . ATTACH PER MANUF. SPEC'S.AND SECURE WITH FURRING NAIL ATSTAKE.
4
(76mm) 3 INCH MULCH LAYER, 36'' MIN.CLEAR OF TURF
5
ROOTBALL SLIGHTLY HIGHER THANFINISHED GRADE.
6
(2) 2" (50mm) DIA. X 8' (2.5M) LONGLODGEPOLE STAKES. NOTE: USE TWOSTAKES FOR TREE'S 15 GALLON (#15)AND LARGER.
7
WATER BASIN.8PLANTING TABLETS PER NOTES ANDSPECIFICATIONS.
9
SOIL BALL RESTING ON FIRM SOIL TOAVOID SETTLING.10
LEGEND:
1
6"
3"
EQ
EQ
EQ
1
2
3
4
56
78
6EXISTING SUBGRADE1
AMENDED PLANTING BACKFILL PERPLANTING NOTES & SPECIFICATIONS(SEE PLANS)
2
ROOTBALL SLIGHTLY HIGHER THANFINISHED GRADE.
3
FINISHED GRADE4
3" MULCH LAYER INSTALLEDBEFORE PLANTING
5
PLANT TYPE AND SPACING ASSPECIFIED ON PLANS
6
EDGE OF PLANTING AREA7
DISTANCE FROM EDGE OF PLANTERTO CENTER OF PLANT TO BE 1/2 THESPECIFIED SPACING
8
LEGEND:
NOTE:
A. KEEP MULCH 2-3" FROM TRUNK OFTREE, SHRUB, OR GROUNDCOVER TYP.
GROUNDCOVER PLANTING2
3"
LEGEND:
1
2
3
4
5
6
7
NOTES:
A. KEEP MULCH 2-3" FROM TRUNK OF TREEOR SHRUB TYP.
PLANTING BACKFILL PER NOTESAND SPECIFICATIONS
1
ROUGHEN SIDES AND BOTTOM OFPIT
2
FINISHED GRADE3
3" MULCH LAYER4
ROOTBALL SLIGHTLY HIGHER THANFINISHED GRADE
5
WATER BASIN6
SOIL BALL RESTING ON FIRM SOILTO AVOID SETTLING
7
SHRUB PLANTING3
LEGEND
ROOT BARRIER
1
2
3 4
5
1
NOTES:A. CONTRACTOR SHALL INSTALL
AND ASSEMBLE ROOT BARRIERPER MANUFACTURERSRECOMMENDATIONS
24" DEEP ROOT BARRIERPER SPECIFICATIONS/EXTEND 10' FROM TRUNKOF TREE IN EACH DIRECTIONALONG FACE OF PAVING,CURB, WALL, ETC.
1
CONCRETE PAVING PERPLAN (WHERE APPLICABLE)
2
EXTEND TOP OF ROOTBARRIER 1/2" MINIMUMABOVE FINISHED GRADE
3
TREE PLANTING PERDETAILS
4
CONCRETE CURB PER PLANS(WHERE APPLICABLE)
5
4
obr
GARR
ICK
OLI
VER
C
HRIS
TOPH
ER B
ITTN
ER
AN
NEY
RO
SEN
THAL
-HAL
L
3817
Ray
Str
eet S
an D
iego
, Ca
9210
4e
in
fo@
obra
rchi
tect
ure.
com
w
obra
rchi
tect
ure.
com
t 6
19.5
64.7
586
f 6
19.5
68.3
636
OBRARCHITECTURE, INC. ALL RIGHTSRESERVED. THE ABOVE DRAWINGS, IDEAS,AND EMBODIED DESIGNS THEREIN ARE THEPROPERTY OF OBRARCHITECTURE, INC. ANDSHALL NOT BE COPIED, REPRODUCED,DISCLOSED TO OTHERS OR USED INCONNECTION WITH ANY WORK OTHER THANTHE SPECIFIED PROJECT FOR WHICH THEYHAVE BEEN PREPARED, IN WHOLE OR INPART, WITHOUT THE PRIOR WRITTENAUTHORIZATION OF OBRARCHITECTURE, INC.
Date Issued
Job No.
Sheet No.
CITY
HAL
L /
PUBL
IC L
IBRA
RY P
ROJE
CTCI
TY O
F LA
GUN
A W
OO
DS24
264
El T
oro
Rd, L
agun
a W
oods
, CA
9263
7
8.03.2021
CLW-006
DN BY: AS, BP CK BY: JJ, JT
08.30.2021PLT DATE:
SDG PRJ # 20-105
PERM
IT S
ET
REVISIONSNo.
12"MIN.12
"
3'-0
" MIN
.
2 TIMES
PALM TREE PLANTING
1
23 4
5
67
119
10
ROUGHEN SIDES AND BOTTOM OF PIT1
FINISHED GRADE2
2 INCH MULCH LAYER3
ROOTBALL 2" HIGHER THAN FINISHEDGRADE (DO NOT TRIM ROOTS)
4
PLANT PALM VERTICAL5
PLANTING TABLETS PER NOTES ANDSPECIFICATIONS
6
PLANTING BACKFILL: -1 PART COARSE WASHED SAND -3 PARTS NATIVE SOIL
7
PERFORATED PVC PIPE WITH IRRIGATIONBUBBLER ON HIGH SIDE OF THE PLANT PIT(SEE TREE BUBBLER DETAILFROM IRRIGATION DETAILS SHEET)
8
COMPACT AND SETTLE SAND/SOILUNDER ROOTBALL TO AVOID SETTLING
9
IMPROVED SOIL-FOR TREE PLANTING -SEE ALSO SPECIFICATIONS.
10
ROOT BALL WIDTH
2"
8
PVC BREATHER TUBE. 4" PERFORATEDPVC PIPE WRAPPED IN FILTER FABRICWITH FLAT GRATE
11
LEGEND:
5
LP-2.0
PLAN
TIN
G DE
TAIL
S
Date Issued 09.08.21
BID
SET