PROJECT
LOCATION
JUNE 2014
PREPARED BY:
.
125 COLLEGE STREET - 4TH FLOOR
BURLINGTON, VERMONT 05401
CITY OF SOUTH BURLINGTON, VERMONT
SOUTH BURLINGTON CITY OFFICE
STORMWATER IMPROVEMENTS
GENERAL NOTES: LEGEND:
SYMBOL DESCRIPTION
STOCKPILED MATERIAL NOTES:
10
78
43
G-0
.1
2
GE
NE
RA
L N
OT
ES
, LE
GE
ND
AN
D D
RA
WIN
G I
ND
EX
11
10
7843
c
10
78
43
C-1
.1
3
EX
IST
ING
SIT
E P
LA
N
11
10
7843
c
11
10
7843
c
NOTES:
SITE PLAN
11
10
7843
c
10
78
43
C-1
.2
4
PR
OP
OS
ED
SIT
E P
LA
N
SECTION
PLAN
-
A
-
A
UNDERGROUND STORMWATER STORAGE CATCH BASIN
INLET/OUTLET DETAILUNDERGROUND STORAGE PLAN
RISER ELEVATION DETAIL
FITTING "B" DETAIL FITTING "C" DETAIL ELEVATION VIEW DETAIL
18" CORRUGATED HDPE BEDDING DETAIL
NOTES:
11
10
7843
c
10
78
43
C-2
.1
5
ST
OR
AG
E P
LA
N
AN
D D
ET
AIL
S
FITTING "D" DETAIL
BIORETENTION FACILITY SECTION A
NOTES:
PLANBIORETENTION UNDERDRAIN SYSTEM DETAIL
6"Ø PERFORATED PIPE DETAIL
11
10
7843
c
10
78
43
C-3
.1
6
BIO
RE
TE
NT
ION
PL
AN
AN
D S
EC
TIO
N
PILOT CHANNEL DETAIL
GRASS SWALE SECTION DETAIL PLAN
NOTES:
11
10
7843
c
10
78
43
C-4
.1
7
VE
GE
TA
TE
D S
WA
LE
PLA
N
AN
D S
EC
TIO
N
DRAINS TO WATERWAYS
DO NOT POLLUTE
DUCTILE IRON
PRE-CAST REINFORCED CONCRETE
CATCH BASIN & DROP INLET DETAIL
H-20 TOP SLAB
DETAIL-A
WALL SLEEVE DETAIL
LOCK-JOINT FLEXIBLE MANHOLE SLEEVE
NOTES:
KOR-N-SEAL JOINT SLEEVE
PIPE CONNECTION TO MANHOLE DETAILS
®
FRAME AND GRATE DETAIL
PVC CATCH BASIN DETAIL
PVC CATCH BASIN DUCTILE IRON
11
10
7843
c
10
78
43
C-5
.1
8
MIS
CE
LL
AN
EO
US
DE
TA
ILS
TYPE B DETAIL
CAST-IN-PLACE CONCRETE CURB
SIDEWALK RAMP TYPE 6 DETAILSIDEWALK RAMP TYPE 6 DETAIL
SEDIMENTATION CONTROL
AT CATCH BASIN
EROSION CONTROL NOTES:
SILT FENCE DETAILTYPICAL STORM DRAIN TRENCH DETAIL
11
10
7843
c
10
78
43
C-5
.2
9
MIS
CE
LL
AN
EO
US
DE
TA
ILS
1
2
3
S
4
12
5
7
SD
SD
SD S
E
30'-91 2
"
25'-4"
13'-5"
32'-3
"
10'
23'-1
01
2"
5'-5"
3'
7'-10" 11'-212"
5'-612"
R25'
TRUNCATED DOMES
DETAIL (TYP.)
6
L200
R32'
R5'
R100'
R8'
R10'
R10'
TREE PRESERVATION
DETAILS
7 & 8
L200
4'-6"
(MATCH EXISTING
SCORING
AT ENTRANCE)
3' (TO TANGENT)
R5'
16'-5"
12'-11"
15'-612"
9'
8'-212"
R3'
R80'
R89'
R3'
R5'-3"
RELOCATE FLAG POLE AT
CENTER OF 5'-3" RADIUS
13'-612"
48'-212"
61'-10"
MIDPOINT
OF ARC
9'-5"BASELINE (BACK OF CURB)
1'-9"
46'-212"
TANGENT
63'-7"
9'
52°
8'-1112
"3'-9
12"
5'-10"23'-3"
24'-612"
40'-2"
22'-4"
26'-212"
46'-412"
50'-10"
5'-6"
6'-512"
24'
TANGENT
TANGENT
304
+LP 3
03.5
2% TO NORTH
EXPANSION JOINT (TYP.)
FLAGPOLE
ANNUAL BED.
SEE NOTE 9 ON
DWG. NO L-200.
TRANSITION TO DROPPED CURB. SEE
NOTE 6 ON DWG. NO. L-200.
MATCH GRADE OF EXISTING
ADJACENT SIDEWALK (TYP.)
SEE NOTE 10 ON DWG. NO.
L-200
3'
LIMIT OF WORK FOR SIDEWALK,
CURBS AND PAVING.
3'
CAST-IN-PLACE CONCRETE
CURB. SEE DETAILS ON
DWG. NO. C-5.2.
3'
GRASS ISLAND. SEE NOTE 8
ON DWG. NO. L-200.
MATCH GRADE OF EXISTING
ADJACENT SIDEWALK.
SEE NOTE 10 ON DWG. NO. L-200.
TRANSITION TO DROPPED CURB. SEE
NOTE 6 ON DWG. NO. L-200.
CONTRACTOR SHALL MOVE
ELECTRIC TO CENTER OF
GRASS ISLAND FOR
FUTURE INSTALLATION.
1
2
3
S
4
12
5
SD
SD
SD S
E
E
RELOCATED BIKE
RACK
BENCHES BY SOUTH
BURLINGTON
JCSG(5)
REFER TO RAIN GARDEN
SOIL MIX ON DETAIL
3/L200
ANNUAL BED
BY SOUTH BURLINGTON.
SEE NOTE 9 ON DWG. NO. L-2OO.
JCHC
MEMORIAL PLAQUE BY SOUTH
BURLINGTON
AVP(14)
TMD(5)
AD(8)
DP(50)
REMOVE APPLE
LIMB EXISTING TREES NORTH OF
PLAZA AND SIDEWALKS FOR
INCREASED VISIBILITY OF
BUILDING ENTRANCE
304
+LP 3
03.5
REMOVE APPLES
X
XX
IE(16)
AG(2)
LSK(18)
AT(14)
HSD(20)
ANC(20)
HKR(20)
EP(14)
AM(16) SS(24)
PNS
revisions
date revisions date
301 college street burlington vermont 05401 802 658 3555
landscape architects planning consultants
http://www.tjboyle.comnorth scale
drawn by date
sheet no:
Site Layout & Planting Plan L-100TKD 10/15/2013
1" = 10'-0"
design byJBO
checked byJBO
South Burlington City Hall EntrywayRevised per South Burlington comments 04/11/2014
11
10
7843
c
NOTE:
CONTRACTOR SHALL FIELD VERIFY SIDEWALK LAYOUT
GEOMETRY AND COORDINATE FINAL LOCATION OF
SIDEWALK RAMPS WITH LAYOUT OF HANDICAPPED
PARKING PLACES PRIOR TO BEGINNING WORK.
T. J. Boyle Associates, LLC
10
SIT
E L
AY
OU
T A
ND
PLA
NT
ING
PL
AN
NOTE:
THE FURNISHING AND INSTALLATION OF ALL PLANTS ON
THIS DRAWING SHALL BE BY SOUTH BURLINGTON. SEE
NOTE 12 ON DRAWING L-200. THE CONTRACTOR SHALL
BE RESPONSIBLE FOR ALL MATERIALS AND WORK
NECESSARY TO PREPARE BEDS SHOWN ON
DRAWING L-100 FOR PLANTING BY OTHERS.
revisions date revisions date
301 college street burlington vermont 05401 802 658 3555
landscape architects planning consultants
http://www.tjboyle.comnorth scale
drawn by date
sheet no:
Planting & Site Details L-200TKD 10/15/2013
1" = 10'-0"
T. J. Boyle Associates, LLC
design byMJB
checked byMJB
South Burlington City Hall Entryway
5" CONCRETE
12" MIN.
CRUSHED GRAVEL
COMPACTED OR
UNDISTURBED SOIL
4X4-W6.0 X W6.0 WELDED WIRE MESH
BROOM FINISH
4000 PSI CONCRETE
140N (MIRAFI) FILTER FABRIC
NOTES:
- PROVIDE EXPANSION JOINT EVERY 25'
- PROVIDE CONTROL JOINTS AS SHOWN ON PLAN, 1/4 - 1/3 THICKNESS OF SLAB
- DO NOT USE CALCIUM CHLORIDE OR OTHER MATERIALS CONTAINING ANTIFREEZE
OR CHEMICAL ACCELERATORS.
- AIR CONTENT: 5-7% AIR ENTRAINMENT
- MAXIMUM WATER-CEMENTITIOUS MATERIALS RATIO: 0.50
- SLUMP LIMIT: 3-4" PRIOR TO ANY WATER REDUCING ADDITIVE
PRUNE TO REMOVE DEADWOOD & CROSSING BRANCHES.
UNDISTURBED OR COMPACTED SOIL MOUND.
3 TIMES
DIAMETER OF
ROOT BALL
REMOVE BURLAP FROM TOP 1/3 OF ROOTBALL. NEVER LEAVE
BURLAP EXPOSED ABOVE SOIL. IF CONTAINER GROWN, REMOVE
POT COMPLETELY. LOOSEN ROOT MASS TO PREVENT GIRDLING.
AMEND BACKFILL AS SPECIFIED, BREAK UP CLODS AND REMOVE
DEBRIS AND STONES.
2" EARTH SAUCER.
2" FINE CHIPPED, PINE BARK MULCH, NOT MORE. DO NOT PLACE
AGAINST PLANT STEM.
TOP OF ROOTBALL TO BE SAME HEIGHT AS PREVIOUSLY GROWN.
2
3
1
L200
PLANT BED DETAIL
DECIDUOUS TREES < 3" CALIPER
SHRUB PLANTING
NTS
NTS
GENERAL PLANTING NOTES:
1. THE CONTRACTOR SHALL LOCATE AND VERIFY THE EXISTENCE OF ALL
UTILITIES PRIOR TO STARTING WORK.
2. THE CONTRACTOR SHALL SUPPLY ALL PLANT MATERIAL IN QUANTITIES
SUFFICIENT TO COMPLETE THE PLANTING SHOWN ON ALL DRAWINGS.
3. ALL MATERIAL SHALL CONFORM TO THE GUIDELINES ESTABLISHED BY THE
CURRENT AMERICAN STANDARD FOR NURSERY STOCK (ANSI) PUBLISHED BY
THE AMERICAN ASSOCIATION OF NURSERYMEN.
4. NO PLANT SHALL BE PUT INTO THE GROUND BEFORE ROUGH GRADING HAS
BEEN FINISHED AND APPROVED BY THE PROJECT LANDSCAPE ARCHITECT OR
EQUAL.
5. PLANTS SHALL BE INSTALLED SUCH THAT THE ROOT FLARE IS AT OR SLIGHTLY
ABOVE FINAL GRADE (DUE TO NURSERY PRACTICES THIS MAY REQUIRE
REMOVING SOIL FROM THE TOP OF THE ROOT BALL TO LOCATE THE ROOT
FLARE.
6. ALL PLANTS SHALL BE BALLED AND BURLAPPED OR CONTAINER GROWN AS
SPECIFIED. NO CONTAINER GROWN STOCK WILL BE ACCEPTED IF IT IS ROOT
BOUND. ALL ROOT WRAPPING MATERIAL MADE OF SYNTHETICS OR PLASTICS
SHALL BE REMOVED AT THE TIME OF PLANTING.
7. WITH CONTAINER GROWN STOCK, THE CONTAINER SHALL BE REMOVED AND
THE CONTAINER BALL SHALL BE CUT THROUGH THE SURFACE IN TWO
VERTICAL LOCATIONS.
8. THE DAY PRIOR TO PLANTING, THE LOCATION OF ALL TREES AND SHRUBS
SHALL BE STAKED FOR APPROVAL BY THE PROJECT LANDSCAPE ARCHITECT
OR EQUAL.
9. LANDSCAPE ARCHITECT MAY REQUIRE ALL PLANTS BE SPRAYED WITH AN
ANTIDESSICANT WITHIN 24 HOURS AFTER PLANTING. IN TEMPERATE ZONES,
ALL PLANTS SHALL BE SPRAYED WITH AN ANTIDESSICANT AT THE BEGINNING
OF THEIR FIRST WINTER.
10. ALL PLANT BEDS MUST HAVE A MINIMUM PLANT BED DEPTH OF 18" WITH A 2/3
TOPSOIL TO 1/3 COMPOST MIX. REMOVE SUBGRADE AND OTHER FILL IN
PLANTING AREAS ON SITE.
11. ALL PLANTS SHALL BE INSTALLED AS PER DETAILS AND THE CONTRACT
SPECIFICATIONS.
12. STAKING PLANTS IS AT THE DISCRETION OF THE CONTRACTOR. ONLY STAKE
PLANTS AS SPECIFIED BY LANDSCAPE ARCHITECT.
13. THE LANDSCAPE CONTRACTOR SHALL PROVIDE AMENDED BACKFILL AS PER
THE CONTRACT SPECIFICATIONS.
14. ALL PLANTS SHALL BE WATERED THOROUGHLY TWICE DURING THE FIRST 24
HOUR PERIOD AFTER PLANTING. ALL PLANTS SHALL THEN BE WATERED
WEEKLY, IF NECESSARY, DURING THE FIRST GROWING SEASON.
15. THE LANDSCAPE CONTRACTOR SHALL REFER TO THE CONTRACT
SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.
16. THE LANDSCAPE CONTRACTOR SHALL REFER TO THE PLANT LIST FOR
SEASONAL REQUIREMENTS RELATED TO THE TIME OF PLANTING.
3 2" X 2" HARDWOOD STAKES 1/3 HEIGHT OF TREE OR MIN. OF 72".
ALLOW FOR A DEPTH OF 12" BELOW UNDISTURBED GRADE. (STAKING
TO BE REMOVED ONE YEAR AFTER PLANTING.) INSTALL STAKES PLUMB.
ROOT FLARE SHALL BE PLANTED AT OR SLIGHTLY ABOVE FINAL GRADE
(DUE TO NURSERY PRACTICES, THIS MAY REQUIRE REMOVING SOIL
FROM THE TOP OF THE ROOT BALL TO LOCATE THE ROOT FLARE).
2"-3" FINE CHIPPED BARK MULCH, NOT MORE. DO NOT PLACE MULCH
DIRECTLY AGAINST TRUNK.
2" EARTH SAUCER.
AMEND BACKFILL AS SPECIFIED, BREAK UP CLODS AND REMOVE
DEBRIS AND STONES.
PRUNE DAMAGED OR BROKEN BRANCHES.
USE WIDE BELT-TYPE TREE TIES; DO NOT USE ROPE OR WIRE IN
HOSE SLEEVES.
REUSABLE PERFORATED PLASTIC TREE WRAP (TO BE REMOVED ONE
YEAR AFTER PLANTING).
3 TIMES
DIAMETER OF
ROOT BALL
SCARIFY SUBGRADE TO 4".
CUT & REMOVE ALL OF THE WIRE BASKET, EXCEPT THAT WHICH IS
UNDER THE ROOT BALL. LEAVE NO BURLAP EXPOSED ABOVE THE
SOIL SURFACE. REMOVE BURLAP FROM THE TOP 1/2 OF ROOT BALL
IF BURLAP IS MADE OF NATURAL FIBER. IF BURLAP IS PLASTIC OR
TREATED, CUT AND REMOVE ALL BUT THAT WHICH IS UNDER THE
ROOT BALL.
USE WIDE BELT TYPE TIES ON EACH MAJOR STEM.ALL MAJOR STEMS
SHOULD BE BELTED TOGETHER.DO NOT USE ROPE OR WIRE IN HOSE
SLEEVES.
2" X 2" X 18" HARDWOOD STAKES 3 PER TREE DRIVEN INTO GROUND.
(STAKING TO BE REMOVED ONE YEAR AFTER PLANTING.)
AMEND BACKFILL AS SPECIFIED, BREAK UP CLODS AND REMOVE
DEBRIS AND STONES.
PRUNE TO REMOVE DEADWOOD & CROSSING BRANCHES.
2"- 3" FINE CHIPPED BARK MULCH, NOT MORE. DO NOT PLACE MULCH
DIRECTLY AGAINST STEMS.
ROOT FLARE SHALL BE PLANTED AT OR SLIGHTLY ABOVE FINAL GRADE
(DUE O NURSERY PRACTICES, THIS MAY REQUIRE REMOVING SOIL
FROM THE TOP OF THE ROOT BALL TO LOCATE THE ROOT FLARE).
3 TIMES
DIAMETER OF
ROOT BALL
4
2" EARTH SAUCER.
UNDISTURBED OR COMPACTED SOIL MOUND.
MULTI-STEM PLANTING
SCARIFY SUBGRADE TO 4".
CUT & REMOVE ALL OF THE WIRE BASKET, EXCEPT THAT WHICH IS
UNDER THE ROOT BALL. LEAVE NO BURLAP EXPOSED ABOVE THE SOIL
SURFACE. REMOVE BURLAP FROM THE TOP 1/2 OF ROOT
BALL IF BURLAP IS MADE OF NATURAL FIBER. IF BURLAP IS PLASTIC OR
TREATED, CUT AND REMOVE ALL BUT THAT WHICH IS UNDER THE ROOT
BALL.
L200
2"-3 FINE CHIPPED BARK MULCH, NO
MORE. DO NOT COVER FOLIAGE. REFER
TO SPECIFICATIONS.
18" MINIMUM PLANT BED DEPTH CONTAINING 2/3
TOPSOIL AND 1/3 COMPOST MIX. (FOR RAIN GARDEN
PLANTING SOIL MIX SEE TABLE ABOVE)
UNDISTURBED OR COMPACTED SOIL.
LAWN
EDGE LAWN PER PLAN, 1" REVEAL
MAX
L200 NTS
L200 NTS
5 CONCRETE PAVING DETAIL
L200 NTS
7 TREE PROTECTION DETAIL
ROOT PRUNING TRENCH MIN 2' DEEP, SEE BLOW UP
TRENCH DETAIL B ABOVE.
TREE PROTECTION FENCE PLACED AT EDGE OF SIDEWALK, CURB, OR 1'
BEYOND DRIPLINE OR FURTHER, IF POSSIBLE.
DRIPLINE OF TREERETENTION AREA
4'
2" STEEL OR WOOD POST
HIGHLY VISIBLE FLAGGING
ORANGE MESH SNOW FENCE
8" WIRE "U" TO SECURE BOTTOM OF FENCE
8'
MAX SECURE FENCE TO HORIZONTAL 2"X4" ALONG TOP
FENCE NOTES:
1. THIS FENCE SERVES AS A TREE PROTECTION DEVICE ONLY.
2. ROOT DAMAGE SHALL BE AVOIDED WITHIN FENCED AREA.
3. FENCE SHALL BE MAINTAINED THROUGHOUT CONSTRUCTION.
8 TYPICAL PROTECTIVE FENCE DETAIL
L200 NTS
L200 NTS
NOTES FOR L-100:
1. ALL NOTES AND DETAILS ON DRAWINGS L-100 AND L-200 APPLY TO THESE SHEETS ONLY.
2. CONTRACTOR SHALL REPAIR/RESTORE ALL LANDSCAPED AREAS IMPACTED BY CONSTRUCTION AS
PER DRAWINGS L-100 AND L-200 AND AS PER SPECIFICATION SECTION 02900.
3. CONTRACTOR SHALL REPLACE/REPAIR PAVEMENT IMPACTED BY CONSTRUCTION AS PER
SPECIFICATION SECTION 02500.
4. LIMIT OF PAVEMENT REPAIR/REPLACEMENT SHALL EXTEND 3' FROM THE EDGE OF NEW CURBS FOR
THE ENTIRE LENGTH.
5. SEE DRAWING L-200 FOR DETAILS FOR NEW SIDEWALK.
6. SEE SIDEWALK RAMP - TYPE 6 DETAILS ON C-5.2 FOR SIDEWALK TRANSITION TO DROPPED CURB.
7. SEE DETAILS ON DRAWING C-5.2 FOR NEW CAST-IN-PLACE CURBS ALONG NEW SIDEWALK AND AT NEW
GRASS ISLAND.
8. LANDSCAPING AT NEW GRASS ISLAND SHALL BE AS PER SPECIFICATION SECTION 02900.
9. CONTRACTOR SHALL FURNISH AND INSTALL 18” MINIMUM DEPTH OF PLANTING MIX AT FLAGPOLE
ANNUAL BED TO GRADE LEVEL. PLANTING MIX SHALL BE AS PER SPECIFICATION SECTION 02900.
10. CONTRACTOR SHALL FIELD VERIFY SIDEWALK LAYOUT GEOMETRY PRIOR TO BEGINNING OF WORK.
NEW SIDEWALK MUST MATCH UP WITH EXISTING SIDEWALKS AND DRIVEWAY ENTRANCE.
11. CONTRACTOR SHALL REMOVE AND RELOCATE ANY EXISTING STRUCTURES, SUCH AS MAIL POST
OFFICE BOX, SIGNS, ETC. IMPACTED BY CONSTRUCTION OF NEW SIDEWALK.
12. ALL TREES, SHRUBS AND PLANTS SHOWN ON THE LANDSCAPING PLAN AND SCHEDULE ON DRAWING
L-100 SHALL BE FURNISHED AND INSTALLED BY SOUTH BURLINGTON AND ARE OUTSIDE OF THE SCOPE
OF THIS CONTRACT. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL MATERIALS AND WORK
NECESSARY TO PREPARE BEDS SHOWN ON DRAWING L-100 FOR PLANTING BY OTHERS.
NOTE FOR L-200:
1. ALL NOTES AND DETAILS ON DRAWINGS L-100 AND L-200 APPLY TO THESE SHEETS ONLY.
SIGN DETAIL
1. ATTACHMENTS OF SIGNS TO TREES IS PROHIBITED.
2. SIGNS SHOULD BE MADE OF VINYL OR PLASTIC.
3. SIGNS SHOULD BE PROPERLY MAINTAINED, PENALTIES WILL BE
ENFORCED FOR REMOVAL OF SIGNS.
4. AVOID INJURY TO ROOTS WHEN PLACING POSTS FOR THE SIGNS.
5. SIGNS SHOULD BE POSTED 50' O.C. AND WITHIN 20' OF THE BEGINNING
AND END OF EACH FENCE TO BE VISIBLE TO ALL CONSTRUCTION
PERSONNEL.
6. SIGNS TO BE SECURELY FASTENED TO THE FENCE OR FENCE POSTS.
7. SIGNS TO HAVE A WHITE BACKGROUND AND ORANGE OR RED TEXT.
ANCHOR POST MUST BE INSTALLED TO A DEPTH OF NO LESS THAN 1/ 3
OF THE TOTAL HEIGHT OF THE POST.
SIGN, SEE DETAIL B ABOVE.
1/3 TOTAL HT.
ROOT PRUNING TRENCH NOTES:
1. USE AN AIR SPADE TO DIG THE 2' TRENCH AND EXPOSE THE ROOTS.
2. EXPOSED ROOTS SHOULD BE CUT WITH A SAW OR LOPPERS TO MAKE
A CLEAN SMOOTH CUT, NOT TORN OR RIPPED.
3. MULCH EXPOSED ROOTS DURING THE CUTTING PROCESS TO KEEP
FROM DRYING OUT.
4. BACKFILL TRENCH WITH MIXTURE OF TOPSOIL AND COMPOST.
1'
1'
CLEAN CUT
EXPOSED ROOTS
IN TRENCH
AIR SPADE TO BE USED
TO DIG 2' TRENCH
TREE ROOTS
6 TRUNCATED DOMES DETAIL
L200 NTS
www.CADdetails.comPROTECTED BY COPYRIGHT - 11/17/09
EAST JORDAN IRON WORKS, INC.
301 SPRING STREET
EAST JORDAN, MI 49727-0439
TOLL FREE: 1-800-626-4653
PHONE: (231)-536-2261
FAX: (231)-536-4458www.ejiw.com
DURALAST DETECTABLE WARNING SURFACE
3. CONTRACTORS NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info REFERENCE NUMBER 978-003.
978-003
NOTES:
1. INSTALLATION TO BE COMPLETED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS.
2. DO NOT SCALE DRAWINGS.
DWP 24X24
B
NON-SLIP SURFACE ONBOTH PLATE & BUTTONS
ANCHOR LUG
(2 PLACES)
LETTERED TAG AREA
(OPTIONAL)
COMPLIANT WITH ADA ACCESSIBILITY
GUIDELINES
A
PRODUCT NUMBER
7005-7
DESIGN FEATURES
MATERIALS:
PLATE-GRAY IRON
ASTM A48 CL35B
DESIGN LOAD:
HEAVY DUTY
COATING:
UNDIPPED
DESIGN INTENT
SLIP RESISTANT SURFACE
CORROSION RESISTANCE
MAINTENANCE FREE
SIMPLIFIED INSTALLATIONØ.90"
Ø.56"
24" SQ.
SECTION B-B
BOTTOM VIEW
SECTION A-A
BUTTON DETAIL
(4) Ø3/4"
VENT HOLES
1 5/16"
2 3/16"B
A
2 3/4"
PLANT
pH RANGE
ORGANIC MATTER
SAND
SILT
CLAY
5.2 TO 7.0
1.5 TO 4.0%
35-60%
30-55%
10-25%
NOTE: PLACEMENT OF PLANTING
SOIL SHOULD BE IN 12" LIFTS,
LOOSELY COMPACTED (LIGHTLY
TAMPED WITH BACKHOE BUCKET).
RAIN GARDEN SOIL MIX (2' DEPTH MINIMUM)
TREE PROTECTION NOTES :
1. PRIOR TO ANY CONSTRUCTION ACTIVITY, ALL TREE PRESERVATION MEASURES MUST BE
IMPLEMENTED.
2. PRIOR TO CONSTRUCTION CONTRACTOR SHALL VERIFY ALL UTILITY LOCATIONS.
3. TREE PROTECTION FENCING SHALL REMAIN INTACT THROUGHOUT ALL CONSTRUCTION ACTIVITY.
4. PRIOR TO THE SITE VISIT ALL TREE PRESERVATION AREAS SHALL BE STAKED OUT ON SITE BY
SURVEY.
5. NO MATERIALS OR EQUIPMENT SHALL BE STORED, STOCKPILED OR OPERATED WITHIN TREE
PROTECTION AREAS.
6. TREE PROTECTED AREAS WILL BE LEFT AS NATURAL AS POSSIBLE.
7. THE CONTRACTOR CHOSEN FOR THIS WORK WILL BE AN EXPERIENCED TREE SERVICE FIRM THAT
HAS SUCCESSFULLY COMPLETED TREE PROTECTION, ROOT PRUNING, AND TRIMMING WORK,
SIMILAR TO THAT REQUIRED FOR THIS PROJECT.
8. IN AREAS OF EXCAVATION NEAR TREE, IDENTIFY AND CUT ROOTS IN CONSULTATION WITH OWNER.
9. REMOVE POORLY ATTACHED AND RUBBING LIMBS. CLEAN THE CROWN OF DEAD, DISEASED AND
WEAK LIMBS. THINNING OF HEALTHY LIMBS IS NOT RECOMMENDED AT THIS TIME.
10. ANY NECESSARY TRENCHING SHALL BE IMMEDIATELY BACKFILLED WITH REMOVED SOIL OR
OTHER HIGHLY ORGANIC SOIL.
11. AN AIR SPADE IS TO BE USED TO EXCAVATE DOWN TO MINIMUM OF 2', SEE DETAIL7B/L200.
12. THERE WILL BE NO EXCAVATION FOR PROPOSED SITE WORK WITHIN FENCED AREA.
11
10
7843
c
11
PL
AN
TIN
G A
ND
SIT
E D
ET
AIL
S