![Page 1: Chemical Resistance Test - Nylok · nyshield tm chemical(resistance(test(continued 24 hour soak at room temperature # vehicle cleaning agent # transit coating / protective wax # car](https://reader030.vdocuments.mx/reader030/viewer/2022021717/5b34458e7f8b9a330e8bebfe/html5/thumbnails/1.jpg)
NYSHIELD TM
CHEMICAL RESISTANCE TEST•24 HOUR SOAK AT ROOM TEMPERATURE
- ENGINE OIL (ALSO 2 HR ELEVATED 82°C)- COOLANT- TRANSMISSION FLUID- POWER STEERING FLUID- WINDSHIELD WASHER FLUID
•2 HOUR SOAK AT ROOM TEMPERATURE- E10 FUEL- E85 FUEL- DIESEL FUEL
RESULTS
•NO VISUAL CHANGE IN COATING APPEARANCE
•NO NOTICEABLE SOFTENING OF COATING
CONFIDENTIAL
![Page 2: Chemical Resistance Test - Nylok · nyshield tm chemical(resistance(test(continued 24 hour soak at room temperature # vehicle cleaning agent # transit coating / protective wax # car](https://reader030.vdocuments.mx/reader030/viewer/2022021717/5b34458e7f8b9a330e8bebfe/html5/thumbnails/2.jpg)
NYSHIELD TM
CHEMICAL RESISTANCE TEST CONTINUED24 HOUR SOAK AT ROOM TEMPERATURE
- VEHICLE CLEANING AGENT- TRANSIT COATING / PROTECTIVE WAX- CAR SHAMPOO- PAINTWORK CLEANING PRODUCT
2 HOUR SOAK AT ROOM TEMPERATURE- WINDEX- RAIN-X 2-IN-1 GLASS CLEANER- REMOVER FOR TRANSIT COATING- WASHER FLUID- 10 MIN SOAK AT ROOM TEMPERATURE- TAR AND ROAD OIL CLEANER- CHROME CLEANER
TESTED PER GMW 14334RESULTS:- NO VISUAL CHANGE IN COATING APPEARANCE- NO NOTICEABLE SOFTENING OF COATING
CONFIDENTIAL