G:\Library/CCEC Product Data/CCEC PDS RotaSec MD Site Prep UK 1.1 - 1 - 04.2006
RotaSec MD120
IMPORTANT
• Any horizontal pipe or conduit runs below the RotaSec must be at least 140mm below FFL.
• It is the customers responsibility to ensure the structural integrity and strength of the installation location.
Concrete Base to BS 5328:1997 specification. Base to be flat and level to +/- 5mm over footprint area. Dimensions to be > 1800 x 3300 x 150 deep min.
Floor Anchors to be drilled during installation, 12mm dia x 100mm deep.
Stator bar ‘dead area’ barrier
Straight bar rotor
Bottom entry conduit location
Fixing locations
Site Preparation RotaSec MD120 (Shown with straight bar rotor)
G:\Library/CCEC Product Data/CCEC PDS RotaSec MD Site Prep UK 1.1 - 2 - 04.2006
Concrete Base to BS 5328:1997 specification. Base to be flat and level to +/- 5mm over footprint area. Dimensions to be > 1800 x 3300 x 150 deep min.
Floor Anchors to be drilled during installation, 12mm dia x 100mm deep.
Stator bar ‘dead area’ barrier
Straight bar rotor
Site Preparation RotaSec MD90 (Shown with straight bar rotor)
IMPORTANT
• Any horizontal pipe or conduit runs below the RotaSec must be at least 140mm below FFL.
• It is the customers responsibility to ensure the structural integrity and strength of the installation location.
G:\Library/CCEC Product Data/CCEC PDS RotaSec MD Site Prep UK 1.1 - 3 - 04.2006
IMPORTANT
• Any horizontal pipe or conduit runs below the RotaSec must be at least 140mm below FFL.
• It is the customers responsibility to ensure the structural integrity and strength of the installation location.
Concrete Base to BS 5328:1997 specification. Base to be flat and level to +/- 5mm over footprint area. Dimensions to be > 1800 x 3300 x 150 deep min.
Floor Anchors to be drilled during installation, 12mm dia x 100mm deep.
Stator bar ‘dead area’ barrier
Straight bar rotor
Site Preparation RotaSec MD90 (Shown with straight bar rotor)
Bottom entry conduit location
Fixing locations
G:\Library/CCEC Product Data/CCEC PDS RotaSec MD Site Prep UK 1.1 - 4 - 04.2006
IMPORTANT
• Any horizontal pipe or conduit runs below the RotaSec must be at least 140mm below FFL.
• It is the customers responsibility to ensure the structural integrity and strength of the installation location.
Bottom entry conduit location
Stator bar ‘dead area’ barrier
Fixing locations
Straight bar rotor
Floor Anchors to be drilled during installation, 12mm dia x 100mm deep.
Concrete Base to BS 5328:1997 specification. Base to be flat and level to +/- 5mm over footprint area. Dimensions to be > 1800 x 3300 x 150 deep min.
Site Preparation RotaSec MD120F (Shown with straight bar rotor)
G:\Library/CCEC Product Data/CCEC PDS RotaSec MD Site Prep UK 1.1 - 5 - 04.2006
IMPORTANT
• Any horizontal pipe or conduit runs below the RotaSec must be at least 140mm below FFL.
• It is the customers responsibility to ensure the structural integrity and strength of the installation location.
Concrete Base to BS 5328:1997 specification. Base to be flat and level to +/- 5mm over footprint area. Dimensions to be > 1800 x 3300 x 150 deep min.
Floor Anchors to be drilled during installation, 12mm dia x 100mm deep.
Straight bar rotor
Bottom entry conduit location
Fixing locations
Site Preparation RotaSec MD120FI (Shown with straight bar rotor)
G:\Library/CCEC Product Data/CCEC PDS RotaSec MD Site Prep UK 1.1 - 6 - 04.2006
IMPORTANT
• Any horizontal pipe or conduit runs below the RotaSec must be at least 140mm below FFL.
• It is the customers responsibility to ensure the structural integrity and strength of the installation location.
Site Preparation RotaSec MD90FI (Shown with straight bar rotor)
Floor Anchors to be drilled during installation, 12mm dia x 100mm deep.
Concrete Base to BS 5328:1997 specification. Base to be flat and level to +/- 5mm over footprint area. Dimensions to be > 1800 x 3300 x 150 deep min.
Stator bar ‘dead area’ barrier
Bottom entry conduit location
Fixing locations
Straight bar rotor
G:\Library/CCEC Product Data/CCEC PDS RotaSec MD Site Prep UK 1.1 - 7 - 04.2006
Site Preparation RotaSec MD120R (Shown with straight bar rotor)
IMPORTANT
• Any horizontal pipe or conduit runs below the RotaSec must be at least 140mm below FFL.
• It is the customers responsibility to ensure the structural integrity and strength of the installation location.
Bottom entry conduit location
Stator bar ‘dead area’ barrier
Fixing locations
Straight bar rotor
Floor Anchors to be drilled during installation, 12mm dia x 100mm deep.
GRP canopy
Walkway down lights
Rain water down pipe
Concrete Base to BS 5328:1997 specification. Base to be flat and level to +/- 5mm over footprint area. Dimensions to be > 1800 x 3300 x 150 deep min.
G:\Library/CCEC Product Data/CCEC PDS RotaSec MD Site Prep UK 1.1 - 8 - 04.2006
IMPORTANT
• Any horizontal pipe or conduit runs below the RotaSec must be at least 140mm below FFL.
• It is the customers responsibility to ensure the structural integrity and strength of the installation location.
Site Preparation RotaSec MD120RI (Shown with straight bar rotor)
Concrete Base to BS 5328:1997 specification. Base to be flat and level to +/- 5mm over footprint area. Dimensions to be > 1800 x 3300 x 150 deep min.
Floor Anchors to be drilled during installation, 12mm dia x 100mm deep.
Rain water down pipe
GRP canopy
Stator bar ‘dead area’ barrier
Bottom entry conduit location
Fixing locations
Straight bar rotor
Walkway down lights
G:\Library/CCEC Product Data/CCEC PDS RotaSec MD Site Prep UK 1.1 - 9 - 04.2006
Site Preparation RotaSec MD90R (Shown with straight bar rotor)
IMPORTANT
• Any horizontal pipe or conduit runs below the RotaSec must be at least 140mm below FFL.
• It is the customers responsibility to ensure the structural integrity and strength of the installation location.
Bottom entry conduit location
Fixing locations
Straight bar rotor
Floor Anchors to be drilled during installation, 12mm dia x 100mm deep.
Concrete Base to BS 5328:1997 specification. Base to be flat and level to +/- 5mm over footprint area. Dimensions to be > 1800 x 3300 x 150 deep min.
GRP canopy
Walkway down lights
Rain water down pipe
Stator bar ‘dead area’ barrier
G:\Library/CCEC Product Data/CCEC PDS RotaSec MD Site Prep UK 1.1 - 10 - 04.2006
Site Preparation RotaSec MD90RI (Shown with straight bar rotor)
IMPORTANT
• Any horizontal pipe or conduit runs below the RotaSec must be at least 140mm below FFL.
• It is the customers responsibility to ensure the structural integrity and strength of the installation location.
Concrete Base to BS 5328:1997 specification. Base to be flat and level to +/- 5mm over footprint area. Dimensions to be > 1800 x 3300 x 150 deep min.
Floor Anchors to be drilled during installation, 12mm dia x 100mm deep.
Fixing locations
Bottom entry conduit location
Walkway down lights
Straight bar rotor Rain water down pipe
GRP canopy
G:\Library/CCEC Product Data/CCEC PDS RotaSec MD Site Prep UK 1.1 - 11 - 04.2006
Site Preparation RotaSec MD120SI (Shown with straight bar rotor)
IMPORTANT
• Any horizontal pipe or conduit runs below the RotaSec must be at least 140mm below FFL.
• It is the customers responsibility to ensure the structural integrity and strength of the installation location.
Floor Anchors to be drilled during installation, 12mm dia x 100mm deep.
Stator bar ‘dead area’ barrier
Concrete Base to BS 5328:1997 specification. Base to be flat and level to +/- 5mm over footprint area. Dimensions to be > 1800 x 3300 x 150 deep min.
Fixing locations
GRP canopy
Bottom entry conduit location
Rain water down pipe
Straight bar rotor
Walkway down lights
GRP side cabinets
G:\Library/CCEC Product Data/CCEC PDS RotaSec MD Site Prep UK 1.1 - 12 - 04.2006
Site Preparation RotaSec MD90S (Shown with straight bar rotor)
IMPORTANT
• Any horizontal pipe or conduit runs below the RotaSec must be at least 140mm below FFL.
• It is the customers responsibility to ensure the structural integrity and strength of the installation location.
Bottom entry conduit location
Stator bar ‘dead area’ barrier
Fixing locations
Straight bar rotor
Floor Anchors to be drilled during installation, 12mm dia x 100mm deep.
Concrete Base to BS 5328:1997 specification. Base to be flat and level to +/- 5mm over footprint area. Dimensions to be > 1800 x 3300 x 150 deep min.
GRP canopy
Walkway down lights
Rain water down pipe
GRP side cabinets
G:\Library/CCEC Product Data/CCEC PDS RotaSec MD Site Prep UK 1.1 - 13 - 04.2006
Site Preparation RotaSec MD90SI (Shown with straight bar rotor)
IMPORTANT
• Any horizontal pipe or conduit runs below the RotaSec must be at least 140mm below FFL.
• It is the customers responsibility to ensure the structural integrity and strength of the installation location.
Concrete Base to BS 5328:1997 specification. Base to be flat and level to +/- 5mm over footprint area. Dimensions to be > 1800 x 3300 x 150 deep min.
Bottom entry conduit location
Fixing locations
Stator bar ‘dead area’ barrier
Straight bar rotor
GRP side cabinets GRP canopy
G:\Library/CCEC Product Data/CCEC PDS RotaSec MD Site Prep UK 1.1 - 14 - 04.2006
A COMPANY WITHIN THE GUNNEBO
HEAD OFFICE SWEDEN Gunnebo AB, Box 5181, SE-402 26 Goteborg, SWEDEN. Tel +46-31 83 68 00, Fax +46-31 83 68 10
www.gunnebo.com
Note: In pursuit of its policy of continuous refinement and improvement, Gunnebo Entrance Control Ltd reserves the right to modify design and details.
For sales enquiries please contact:
________________________________
Competence Centre Entrance Control
Gunnebo Entrance Control Ltd. Bellbrook Business Park, Uckfield, East Sussex, TN22 lQQ, UK. Tel +44 (0) 1825 761022 Fax +44 (0) 1825 763835
E-mail [email protected] Web www.gunneboentrance.com
ISO 9001 FM 13503