![Page 1: CATALOGO ECOSTAR 2017 - SOLCLIMEsolclime.net/wp/cat/catalogo ecostar resumen NG series 2017.pdf · /kp mecn j /cz mecn j /kp m9 m9 /cz m9 8#% /kp 0o j /kp 0o j /cz 0o j /cz 0o j 0#674#](https://reader030.vdocuments.mx/reader030/viewer/2022041102/5edde774ad6a402d666922da/html5/thumbnails/1.jpg)
![Page 2: CATALOGO ECOSTAR 2017 - SOLCLIMEsolclime.net/wp/cat/catalogo ecostar resumen NG series 2017.pdf · /kp mecn j /cz mecn j /kp m9 m9 /cz m9 8#% /kp 0o j /kp 0o j /cz 0o j /cz 0o j 0#674#](https://reader030.vdocuments.mx/reader030/viewer/2022041102/5edde774ad6a402d666922da/html5/thumbnails/2.jpg)
78
Pls. scan for electronic catalogue.
NG
SER
IES
GAS
BU
RNER
S
CAPACITY TABLES
NEW GENERATION MODULATING GAS BURNERS
BURNER TYPE
215.000
258.000
258.000
516.000
602.000
688.000
1.290.000
1.290.000
1.720.000
2.150.000
2.580.000
5.160.000
6.020.000
6.880.000
9,6
11,5
11,5
19,1
22,2
22,9
26,8
95,6
155,6
267,6
250
500
580
600
700
800
850
900
1.100
1.500
1.500
2.000
2.500
6.000
7.000
8.000
8.500
9.000
10.500
12.000
2,20
5,5
7,5
11,00
11,00
15,00
18,50
22,00
22,00
22,00
26,1
52,1
60,5
62,5
88,6
208,5
260,6
625,5
729,7
886,1
1.250,9
CAPACITY CAPACITY
Min.kcal/h
Max.kcal/h
Min.kW kW
Max.kW VAC
Min. Nm3/h
Min. Nm3/h
Max. Nm3/h
Max. Nm3/h
NATURAL GASCONSUMPTION
LPG CONSUMPTIONFAN
MOTOR POWER
VOLTAGE AT 50 Hz
NG SERIES GAS BURNERS
![Page 3: CATALOGO ECOSTAR 2017 - SOLCLIMEsolclime.net/wp/cat/catalogo ecostar resumen NG series 2017.pdf · /kp mecn j /cz mecn j /kp m9 m9 /cz m9 8#% /kp 0o j /kp 0o j /cz 0o j /cz 0o j 0#674#](https://reader030.vdocuments.mx/reader030/viewer/2022041102/5edde774ad6a402d666922da/html5/thumbnails/3.jpg)
79
www.ecostarburners.com
NG
SER
IES
GAS
BU
RNER
S
TECHNICAL SPECIFICATIONS
High performance fan,
BURNER DIMENSIONS
![Page 4: CATALOGO ECOSTAR 2017 - SOLCLIMEsolclime.net/wp/cat/catalogo ecostar resumen NG series 2017.pdf · /kp mecn j /cz mecn j /kp m9 m9 /cz m9 8#% /kp 0o j /kp 0o j /cz 0o j /cz 0o j 0#674#](https://reader030.vdocuments.mx/reader030/viewer/2022041102/5edde774ad6a402d666922da/html5/thumbnails/4.jpg)
80
Pls. scan for electronic catalogue.
NG
SER
IES
GAS
BU
RNER
S
1560
1560
1560
1855
2005
2005
1860
1860
1860
1955
1955
1955
1955
280
280
280
200
200
200
890
890
890
1000
1000
1000
1210
1210
1210
560
560
560
610
610
610
620
620
620
620
770
770
770
1060
1060
1060
515
515
515
685
685
685
1055
1055
1055
1055
18
18
18
18
18
18
18
18
18
22
22
22
22
275
275
275
275
275
275
218
218
218
250
250
508
508
508
508
-
280
280
-
-
-
-
-
-
-
BACK PRESSURE DIAGRAMS
kWkW
kW
kWkW
kW
![Page 5: CATALOGO ECOSTAR 2017 - SOLCLIMEsolclime.net/wp/cat/catalogo ecostar resumen NG series 2017.pdf · /kp mecn j /cz mecn j /kp m9 m9 /cz m9 8#% /kp 0o j /kp 0o j /cz 0o j /cz 0o j 0#674#](https://reader030.vdocuments.mx/reader030/viewer/2022041102/5edde774ad6a402d666922da/html5/thumbnails/5.jpg)
81
www.ecostarburners.com
NG
SER
IES
GAS
BU
RNER
S
kW kW
kW kW
kW kW
kW
![Page 6: CATALOGO ECOSTAR 2017 - SOLCLIMEsolclime.net/wp/cat/catalogo ecostar resumen NG series 2017.pdf · /kp mecn j /cz mecn j /kp m9 m9 /cz m9 8#% /kp 0o j /kp 0o j /cz 0o j /cz 0o j 0#674#](https://reader030.vdocuments.mx/reader030/viewer/2022041102/5edde774ad6a402d666922da/html5/thumbnails/6.jpg)
82
Pls. scan for electronic catalogue.
NG
SER
IES
LIG
HT
OIL
BU
RNER
S
CAPACITY TABLES
NEW GENERATION MODULATING LIGHT OIL BURNERS
BURNER TYPE
1.806.000
5.160.000
6.020.000
6.880.000
980
1.120
1.190
1.260
2.100
6.000
7.000
8.000
8.500
9.000
10.500
12.000
11,00
11,00
15,00
18,50
22,00
22,00
22,00
70,8
82,6
106,2
129,8
177,1
505,9
590,2
716,7
758,8
1.011,8
CAPACITY CAPACITY
Min.kcal/h
Max.kcal/h
Min.kW kW
Max.kW VAC
Min. kg/h
Max. kg/h
LIGHT OILCONSUMPTION
FANMOTOR POWER
VOLTAGE AT 50 Hz
NG SERIES LIGHT OIL BURNERS
![Page 7: CATALOGO ECOSTAR 2017 - SOLCLIMEsolclime.net/wp/cat/catalogo ecostar resumen NG series 2017.pdf · /kp mecn j /cz mecn j /kp m9 m9 /cz m9 8#% /kp 0o j /kp 0o j /cz 0o j /cz 0o j 0#674#](https://reader030.vdocuments.mx/reader030/viewer/2022041102/5edde774ad6a402d666922da/html5/thumbnails/7.jpg)
83
www.ecostarburners.com
NG
SER
IES
LIGH
T O
IL B
URN
ERS
TECHNICAL SPECIFICATIONS
BURNER DIMENSIONS
High performance fan,
![Page 8: CATALOGO ECOSTAR 2017 - SOLCLIMEsolclime.net/wp/cat/catalogo ecostar resumen NG series 2017.pdf · /kp mecn j /cz mecn j /kp m9 m9 /cz m9 8#% /kp 0o j /kp 0o j /cz 0o j /cz 0o j 0#674#](https://reader030.vdocuments.mx/reader030/viewer/2022041102/5edde774ad6a402d666922da/html5/thumbnails/8.jpg)
84
Pls. scan for electronic catalogue.
NG
SER
IES
LIG
HT
OIL
BU
RNER
S
BACK PRESSURE DIAGRAMS
kW kW
kW kW
kWkW
kW
![Page 9: CATALOGO ECOSTAR 2017 - SOLCLIMEsolclime.net/wp/cat/catalogo ecostar resumen NG series 2017.pdf · /kp mecn j /cz mecn j /kp m9 m9 /cz m9 8#% /kp 0o j /kp 0o j /cz 0o j /cz 0o j 0#674#](https://reader030.vdocuments.mx/reader030/viewer/2022041102/5edde774ad6a402d666922da/html5/thumbnails/9.jpg)
85
www.ecostarburners.com
NG
SER
IES
LIGH
T O
IL B
URN
ERS
ECO
50
G C
3 N
GEC
O 8
O L
C 3
NG
ECO
55
G C
3 N
GEC
O 8
O L
C 3
a N
G
ECO
55
G C
3a
NG
ECO
60
G C
3 N
G
ECO
65
G C
3 N
G
ECO
70
G C
3 N
G
ECO
8 G
C 3
NG
ECO
8 G
C 3
a N
G
ECO
8 G
C 3
b N
G
ECO
9 G
C 3
NG
ECO
9 G
C 3
a N
G
ECO
9 G
C 3
b N
G
ECO
9 G
C 3
c N
G
ECO
8 O
L C
3 b
NG
ECO
9 O
L C
3 N
G
ECO
9 O
L C
3a
NG
ECO
9 O
L C
3b
NG
ECO
9 O
L C
3c
NG
Ignition
Air pressure switch
Hinged body for easy maintanance
Ignition
Air pressure switch
Hinged body for easy maintanance
DI DI DI DI DI DI
1S
DI
Modulating2S
º
ONE STAGE TWO STAGE
![Page 10: CATALOGO ECOSTAR 2017 - SOLCLIMEsolclime.net/wp/cat/catalogo ecostar resumen NG series 2017.pdf · /kp mecn j /cz mecn j /kp m9 m9 /cz m9 8#% /kp 0o j /kp 0o j /cz 0o j /cz 0o j 0#674#](https://reader030.vdocuments.mx/reader030/viewer/2022041102/5edde774ad6a402d666922da/html5/thumbnails/10.jpg)
86
Pls. scan for electronic catalogue.
NG
SER
IES
HEA
VY O
IL B
UR
NER
S
CAPACITY TABLES
NEW GENERATION MODULATING HEAVY OIL BURNERS
BURNER TYPE
1.806.000
5.160.000
6.020.000
6.880.000
980
1.120
1.190
1.260
2.100
6.000
7.000
8.000
8.500
9.000
10.500
12.000
11,00
11,00
15,00
18,50
22,00
22,00
22,00
99,8
106,1
187,2
757,5
802,1
CAPACITY CAPACITY
Min.kcal/h
Max.kcal/h
Min.kW kW
Max.kW VAC
Min. kg/h
Max. kg/h
HEAVY-OIL CONSUMPTIONFAN
MOTOR POWER
VOLTAGE AT 50 Hz
NG SERIES HEAVY OIL BURNERS
![Page 11: CATALOGO ECOSTAR 2017 - SOLCLIMEsolclime.net/wp/cat/catalogo ecostar resumen NG series 2017.pdf · /kp mecn j /cz mecn j /kp m9 m9 /cz m9 8#% /kp 0o j /kp 0o j /cz 0o j /cz 0o j 0#674#](https://reader030.vdocuments.mx/reader030/viewer/2022041102/5edde774ad6a402d666922da/html5/thumbnails/11.jpg)
87
www.ecostarburners.com
NG
SER
IES
HEA
VY O
IL B
UR
NER
S
TECHNICAL SPECIFICATIONS
BURNER DIMENSIONS
High performance fan,
![Page 12: CATALOGO ECOSTAR 2017 - SOLCLIMEsolclime.net/wp/cat/catalogo ecostar resumen NG series 2017.pdf · /kp mecn j /cz mecn j /kp m9 m9 /cz m9 8#% /kp 0o j /kp 0o j /cz 0o j /cz 0o j 0#674#](https://reader030.vdocuments.mx/reader030/viewer/2022041102/5edde774ad6a402d666922da/html5/thumbnails/12.jpg)
88
Pls. scan for electronic catalogue.
NG
SER
IES
HEA
VY O
IL B
UR
NER
S
BACK PRESSURE DIAGRAMS
kW kW
kW kW
kW kW
kW
![Page 13: CATALOGO ECOSTAR 2017 - SOLCLIMEsolclime.net/wp/cat/catalogo ecostar resumen NG series 2017.pdf · /kp mecn j /cz mecn j /kp m9 m9 /cz m9 8#% /kp 0o j /kp 0o j /cz 0o j /cz 0o j 0#674#](https://reader030.vdocuments.mx/reader030/viewer/2022041102/5edde774ad6a402d666922da/html5/thumbnails/13.jpg)
89
www.ecostarburners.com
NG
SER
IES
HEA
VY O
IL B
UR
NER
S
ECO
8 O
S C
3 N
G
ECO
8 O
S C
3 a
NG
ECO
8 O
S C
3 b
NG
ECO
9 O
S C
3 N
G
ECO
9 O
S C
3a
NG
ECO
9 O
S C
3b
NG
ECO
9 O
S C
3c
NG
Air pressure switch
Heating and pumping station
Hinged body for easy maintanance
1S
DI
Modulating2S
º
ONE STAGE TWO STAGE
![Page 14: CATALOGO ECOSTAR 2017 - SOLCLIMEsolclime.net/wp/cat/catalogo ecostar resumen NG series 2017.pdf · /kp mecn j /cz mecn j /kp m9 m9 /cz m9 8#% /kp 0o j /kp 0o j /cz 0o j /cz 0o j 0#674#](https://reader030.vdocuments.mx/reader030/viewer/2022041102/5edde774ad6a402d666922da/html5/thumbnails/14.jpg)
90
Pls. scan for electronic catalogue.
NG
SER
IES
DU
AL B
URN
ERS
CAPACITY TABLES
NEW GENERATION MODULATING GAS-HEAVY OIL BURNERS
NG SERIES GAS - HEAVY OIL BURNERS
BURNER TYPE
516,000
602,000
688,000
1,290,000
5,160,000
6,020,000
6,880,000
1,806,000
5,160,000
6,020,000
6,880,000
600
700
800
850
900
1,100
1,500
980
1,120
1,190
1,260
2,100
99.8
106.1
187.2
6,000
7,000
8,000
8,500
9,000
10,500
12,000
6,000
7,000
8,000
8,500
9,000
10,500
12,000
757.5
802.1
89
115
156
625
886
1,095
1,251
11.00
11.00
15.00
18.50
22.00
22.00
22.00
NATURAL GAS CAPACITY
NATURAL GAS CAPACITY
Min.kcal/h
Min.kcal/h
Max.kcal/h
Max.kcal/h
Min.kW
Min.kW
Min. kg/h
Max.kW
Max.kW
Max. kg/h
Min. Nm3/h
Max. Nm3/h kW VAC
NATURAL GAS CONSUMPTION
HEAVY-OIL CAPACITY
HEAVY-OIL CAPACITY
HEAVY-OIL CONS.
FANMOTOR POWER
VOLTAGE AT 50 Hz
![Page 15: CATALOGO ECOSTAR 2017 - SOLCLIMEsolclime.net/wp/cat/catalogo ecostar resumen NG series 2017.pdf · /kp mecn j /cz mecn j /kp m9 m9 /cz m9 8#% /kp 0o j /kp 0o j /cz 0o j /cz 0o j 0#674#](https://reader030.vdocuments.mx/reader030/viewer/2022041102/5edde774ad6a402d666922da/html5/thumbnails/15.jpg)
91
www.ecostarburners.com
NG
SER
IES
DU
AL B
URN
ERS
TECHNICAL SPECIFICATIONS
BURNER DIMENSIONS
High performance fan,
![Page 16: CATALOGO ECOSTAR 2017 - SOLCLIMEsolclime.net/wp/cat/catalogo ecostar resumen NG series 2017.pdf · /kp mecn j /cz mecn j /kp m9 m9 /cz m9 8#% /kp 0o j /kp 0o j /cz 0o j /cz 0o j 0#674#](https://reader030.vdocuments.mx/reader030/viewer/2022041102/5edde774ad6a402d666922da/html5/thumbnails/16.jpg)
92
Pls. scan for electronic catalogue.
NG
SER
IES
DU
AL B
URN
ERS
BACK PRESSURE DIAGRAMS
kW kW
kW kW
kW kW
kW
![Page 17: CATALOGO ECOSTAR 2017 - SOLCLIMEsolclime.net/wp/cat/catalogo ecostar resumen NG series 2017.pdf · /kp mecn j /cz mecn j /kp m9 m9 /cz m9 8#% /kp 0o j /kp 0o j /cz 0o j /cz 0o j 0#674#](https://reader030.vdocuments.mx/reader030/viewer/2022041102/5edde774ad6a402d666922da/html5/thumbnails/17.jpg)
93
www.ecostarburners.com
NG
SER
IES
DU
AL B
URN
ERS
ECO
8 K
S C
3 N
G
ECO
8 K
S C
3 a
NG
ECO
8 K
S C
3 b
NG
ECO
9 K
S C
3 N
G
ECO
9 K
S C
3a
NG
ECO
9 K
S C
3b
NG
ECO
9 K
S C
3c
NG
Air pressure switch
Heating and pumping station
Hinged body for easy maintanance
1S
DI
Modulating2S
º
ONE STAGE TWO STAGE
![Page 18: CATALOGO ECOSTAR 2017 - SOLCLIMEsolclime.net/wp/cat/catalogo ecostar resumen NG series 2017.pdf · /kp mecn j /cz mecn j /kp m9 m9 /cz m9 8#% /kp 0o j /kp 0o j /cz 0o j /cz 0o j 0#674#](https://reader030.vdocuments.mx/reader030/viewer/2022041102/5edde774ad6a402d666922da/html5/thumbnails/18.jpg)
94
Pls. scan for electronic catalogue.
NG
SER
IES
DU
AL B
URN
ERS
CAPACITY TABLES
NEW GENERATION MODULATING GAS-LIGHT OIL BURNERS
NG SERIES GAS - LIGHT OIL BURNERS
BURNER TYPE
516,000
602,000
688,000
1,290,000
5,160,000
6,020,000
6,880,000
1,806,000
5,160,000
6,020,000
6,880,000
600
700
800
850
900
1,100
1,500
980
1,120
1,190
1,260
2,100
70.8
82.6
106.2
129.8
177.1
6,000
7,000
8,000
8,500
9,000
10,500
12,000
6,000
7,000
8,000
8,500
9,000
10,500
12,000
505.9
590.2
716.7
758.8
1,011.8
89
115
156
625
886
1,095
1,251
11.00
11.00
15.00
18.50
22.00
22.00
22.00
NATURAL GAS CAPACITY
NATURAL GAS CAPACITY
Min.kcal/h
Min. kcal/h
Max.kcal/h
Max.kcal/h
Min.kW
Min.kW
Min. kg/h
Max.kW
Max.kW
Max. kg/h
Min. Nm3/h
Max. Nm3/h kW VAC
NATURAL GAS CONSUMPTION
LIGHT OILCAPACITY
LIGHT OILCAPACITY
LIGHT OILCONS.
FANMOTOR POWER
VOLTAGE AT 50 Hz
![Page 19: CATALOGO ECOSTAR 2017 - SOLCLIMEsolclime.net/wp/cat/catalogo ecostar resumen NG series 2017.pdf · /kp mecn j /cz mecn j /kp m9 m9 /cz m9 8#% /kp 0o j /kp 0o j /cz 0o j /cz 0o j 0#674#](https://reader030.vdocuments.mx/reader030/viewer/2022041102/5edde774ad6a402d666922da/html5/thumbnails/19.jpg)
95
www.ecostarburners.com
NG
SER
IES
DU
AL B
URN
ERS
TECHNICAL SPECIFICATIONS
BURNER DIMENSIONS
High performance fan,
![Page 20: CATALOGO ECOSTAR 2017 - SOLCLIMEsolclime.net/wp/cat/catalogo ecostar resumen NG series 2017.pdf · /kp mecn j /cz mecn j /kp m9 m9 /cz m9 8#% /kp 0o j /kp 0o j /cz 0o j /cz 0o j 0#674#](https://reader030.vdocuments.mx/reader030/viewer/2022041102/5edde774ad6a402d666922da/html5/thumbnails/20.jpg)
96
Pls. scan for electronic catalogue.
NG
SER
IES
DU
AL B
URN
ERS
BACK PRESSURE DIAGRAMS
kW kW
kWkW
kW kW
kW
![Page 21: CATALOGO ECOSTAR 2017 - SOLCLIMEsolclime.net/wp/cat/catalogo ecostar resumen NG series 2017.pdf · /kp mecn j /cz mecn j /kp m9 m9 /cz m9 8#% /kp 0o j /kp 0o j /cz 0o j /cz 0o j 0#674#](https://reader030.vdocuments.mx/reader030/viewer/2022041102/5edde774ad6a402d666922da/html5/thumbnails/21.jpg)
97
www.ecostarburners.com
NG
SER
IES
DU
AL B
URN
ERS
ECO
8 K
L C
3 N
G
ECO
8 K
L C
3 a
NG
ECO
8 K
L C
3 b
NG
ECO
9 K
L C
3 N
G
ECO
9 K
L C
3a
NG
ECO
9 K
L C
3b
NG
ECO
9 K
L C
3c
NG
Air pressure switch
Hinged body for easy maintanance
1S
DI
Modulating2S
º
ONE STAGE TWO STAGE
![Page 22: CATALOGO ECOSTAR 2017 - SOLCLIMEsolclime.net/wp/cat/catalogo ecostar resumen NG series 2017.pdf · /kp mecn j /cz mecn j /kp m9 m9 /cz m9 8#% /kp 0o j /kp 0o j /cz 0o j /cz 0o j 0#674#](https://reader030.vdocuments.mx/reader030/viewer/2022041102/5edde774ad6a402d666922da/html5/thumbnails/22.jpg)
98
Pls. scan for electronic catalogue.
ELECTRONIC AIR/FUEL CONTROL