BRIEF VIEW OF CONTENTS
1. INTRODUCTION
2. PROCESS FLOW AND VARIABLES
3. CAPSULE FILLING
MECHANISM
4. QUALIFICIATIONS
5. REFERENCES
![Page 3: Capsule Filling MC Validation](https://reader033.vdocuments.mx/reader033/viewer/2022061504/55cf8f03550346703b98068e/html5/thumbnails/3.jpg)
CAPSULE:
“They are generally gelatin shells filled with the ingredients that make up an individual dose.”
Dry powders, semi-solids, and liquids that do not dissolve gelatin may be encapsulated.
Capsules account for about 20% of all prescriptions dispensed.
1.INTRODUCTION
![Page 4: Capsule Filling MC Validation](https://reader033.vdocuments.mx/reader033/viewer/2022061504/55cf8f03550346703b98068e/html5/thumbnails/4.jpg)
Advantages:
I. They may be used to mask the unpleasant tastes, aromas, or appearance of a drug.
II. They allow powders to be dispensed in an uncompressed form, thus allowing for quicker dissolution and absorption of the drug following oral dosing (as compared with tablets).
III. They offer the pharmacist versatility to prepare any dose desired for a variety of administration routes (e.g. oral, inhalation, rectal, or to be diluted for vaginal, rectal, oral or topical use) and thus aid to alter release rate.
IV. They may be easier than tablets for some people to swallow.
INTRODUCTION
![Page 5: Capsule Filling MC Validation](https://reader033.vdocuments.mx/reader033/viewer/2022061504/55cf8f03550346703b98068e/html5/thumbnails/5.jpg)
Disadvantages:
I. They are easily tampered with (although techniques exist for preventing this).
II. They are subject to the effects of relative humidity and to microbial contamination.
III. They may be difficult for some people to swallow.
IV. More expensive (commercially)
INTRODUCTION
![Page 6: Capsule Filling MC Validation](https://reader033.vdocuments.mx/reader033/viewer/2022061504/55cf8f03550346703b98068e/html5/thumbnails/6.jpg)
Properties:
Hard Gelatin Capsules consists of a Base or a Body and a Shorter Cap.
For human use, eight sizes of capsules are available. The capacity of each size varies according to the combination of drugs and their apparent densities.
Capsules are available as clear gelatin capsules or in a variety of colors.
The pharmacist can use the different colored capsules to distinguish two capsule formulations for the same patient, or to encapsulate unattractive ingredients.
INTRODUCTION
![Page 7: Capsule Filling MC Validation](https://reader033.vdocuments.mx/reader033/viewer/2022061504/55cf8f03550346703b98068e/html5/thumbnails/7.jpg)
INTRODUCTION
Sr No. Capsule Size
Volume (ml)
Lactose(mg)
Aspirin(mg)
1. 000 1.37 1340 1000
2. 00 0.95 929 600
3. 0 0.68 665 500
4. 1 0.50 489 300
5. 2 0.37 362 250
6. 3 0.30 293 200
7. 4 0.20 195 125
8. 5 0.13 127 60
Various Sizes of Capsules:
![Page 8: Capsule Filling MC Validation](https://reader033.vdocuments.mx/reader033/viewer/2022061504/55cf8f03550346703b98068e/html5/thumbnails/8.jpg)
INTRODUCTION
Various Sizes of Capsules:
![Page 9: Capsule Filling MC Validation](https://reader033.vdocuments.mx/reader033/viewer/2022061504/55cf8f03550346703b98068e/html5/thumbnails/9.jpg)
EQUIPMENT VALIDATION IMPORTANCE:
1. Safety
2. Fewer Interruptions of Work
3. Elimination of Premature Replacements
4. cGMP Requirement
5. Reduction of Variation in Results
6. Greater Confidence in the Reliability of Results
INTRODUCTION
![Page 10: Capsule Filling MC Validation](https://reader033.vdocuments.mx/reader033/viewer/2022061504/55cf8f03550346703b98068e/html5/thumbnails/10.jpg)
EQUIPMENT VALIDATION IMPORTANCE:
1. Safety
2. Fewer Interruptions of Work
3. Elimination of Premature Replacements
4. cGMP Requirement
5. Reduction of Variation in Results
6. Greater Confidence in the Reliability of Results
INTRODUCTION
![Page 11: Capsule Filling MC Validation](https://reader033.vdocuments.mx/reader033/viewer/2022061504/55cf8f03550346703b98068e/html5/thumbnails/11.jpg)
EQUIPMENT VALIDATION IMPORTANCE:
1. Safety
2. Fewer Interruptions of Work
3. Elimination of Premature Replacements
4. cGMP Requirement
5. Reduction of Variation in Results
6. Greater Confidence in the Reliability of Results
INTRODUCTION
![Page 12: Capsule Filling MC Validation](https://reader033.vdocuments.mx/reader033/viewer/2022061504/55cf8f03550346703b98068e/html5/thumbnails/12.jpg)
EQUIPMENT VALIDATION IMPORTANCE:
1. Safety
2. Fewer Interruptions of Work
3. Elimination of Premature Replacements
4. cGMP Requirement
5. Reduction of Variation in Results
6. Greater Confidence in the Reliability of Results
INTRODUCTION
![Page 13: Capsule Filling MC Validation](https://reader033.vdocuments.mx/reader033/viewer/2022061504/55cf8f03550346703b98068e/html5/thumbnails/13.jpg)
EQUIPMENT VALIDATION IMPORTANCE:
1. Safety
2. Fewer Interruptions of Work
3. Elimination of Premature Replacements
4. cGMP Requirement
5. Reduction of Variation in Results
6. Greater Confidence in the Reliability of Results
INTRODUCTION
![Page 14: Capsule Filling MC Validation](https://reader033.vdocuments.mx/reader033/viewer/2022061504/55cf8f03550346703b98068e/html5/thumbnails/14.jpg)
EQUIPMENT VALIDATION IMPORTANCE:
1. Safety
2. Fewer Interruptions of Work
3. Elimination of Premature Replacements
4. cGMP Requirement
5. Reduction of Variation in Results
6. Greater Confidence in the Reliability of Results
INTRODUCTION
![Page 15: Capsule Filling MC Validation](https://reader033.vdocuments.mx/reader033/viewer/2022061504/55cf8f03550346703b98068e/html5/thumbnails/15.jpg)
WHO SHOULD DO EQUIPMENT VALIDATION:
VENDOR OR USER???
1. DQ is always done by the User
2. IQ for small and low cost instrument is done by the
User
3. IQ for large, complex and high cost instrument is
done by the Vendor
4. OQ can be done either by the User or Vendor
5. PQ should always be done by the User
INTRODUCTION
![Page 16: Capsule Filling MC Validation](https://reader033.vdocuments.mx/reader033/viewer/2022061504/55cf8f03550346703b98068e/html5/thumbnails/16.jpg)
2. PROCESS FLOW AND VARIABLES
PROCESS FLOW CONTROL VARIABLES MEASURED RESPONSED
ADDITION OF:1. RAW MATERIALS,2. API AND3. EXCIPIENTS
MIXING AND MIXER
ADDITION OF LUBRICANTS AND DISINTEGRANTS
BLENDING AND BLENDER
CAPSULATING
1. LOAD SIZE2. RPM3. MIXING TIME
1. LOAD SIZE2. RPM3. BLENDING TIME
1. CAPSULATION SPEED2. POWER FEED RATE
MIX UNIFORMITY
1. WEIGHT VARIATION2. DISINTEGRATION TIME AND3. LOCKING
1. BLEND UNIFORMITY2. FLOW CHARACTERISTICS
![Page 17: Capsule Filling MC Validation](https://reader033.vdocuments.mx/reader033/viewer/2022061504/55cf8f03550346703b98068e/html5/thumbnails/17.jpg)
FILLING OF VARIOUS ENTITIES
TABLET FILL
PELLET FILL
PELLET MIX FILL
LIQUID FILL
![Page 18: Capsule Filling MC Validation](https://reader033.vdocuments.mx/reader033/viewer/2022061504/55cf8f03550346703b98068e/html5/thumbnails/18.jpg)
3. TYPES OF CAPSULE FILLING
MECHANISM
1. Tamping-In and Stroking
2. Continuous Tamping
3. Auger Filling
4. Compression Filling
5. Vacuum Fill
![Page 19: Capsule Filling MC Validation](https://reader033.vdocuments.mx/reader033/viewer/2022061504/55cf8f03550346703b98068e/html5/thumbnails/19.jpg)
v v V
STROKING IN AND TAMPING MACHINE
CAPSULE BODY DOSING DISCPOWDER OR GRANULATE
TAMPING AND VOLUME FILL
![Page 20: Capsule Filling MC Validation](https://reader033.vdocuments.mx/reader033/viewer/2022061504/55cf8f03550346703b98068e/html5/thumbnails/20.jpg)
v v V
![Page 21: Capsule Filling MC Validation](https://reader033.vdocuments.mx/reader033/viewer/2022061504/55cf8f03550346703b98068e/html5/thumbnails/21.jpg)
AGITATOR
AUGER FEED MECHANISM
DOSAGE HOPPER
PICK-UP RING FOR CAPSULE BODIES
AUGER MECHANISM OF FILLING
![Page 22: Capsule Filling MC Validation](https://reader033.vdocuments.mx/reader033/viewer/2022061504/55cf8f03550346703b98068e/html5/thumbnails/22.jpg)
DOSING PISTON
LIQUID FILL
CAPSULE BODY
OUTLET VALVE
LIQUID/ SEMISOLID
FILLING METHOD
![Page 23: Capsule Filling MC Validation](https://reader033.vdocuments.mx/reader033/viewer/2022061504/55cf8f03550346703b98068e/html5/thumbnails/23.jpg)
![Page 24: Capsule Filling MC Validation](https://reader033.vdocuments.mx/reader033/viewer/2022061504/55cf8f03550346703b98068e/html5/thumbnails/24.jpg)
v v v v vv
BASE PLATE
DOSING DISC
TAMPING STATION
1ST 2ND 3RD
4TH
TRANSFER STATION
DETECTOR TAMPING PUNCH
CAPSULE BODY
CONTINOUS TAMPING FILLING
![Page 25: Capsule Filling MC Validation](https://reader033.vdocuments.mx/reader033/viewer/2022061504/55cf8f03550346703b98068e/html5/thumbnails/25.jpg)
v v v v vv
![Page 26: Capsule Filling MC Validation](https://reader033.vdocuments.mx/reader033/viewer/2022061504/55cf8f03550346703b98068e/html5/thumbnails/26.jpg)
v v v v vv
![Page 27: Capsule Filling MC Validation](https://reader033.vdocuments.mx/reader033/viewer/2022061504/55cf8f03550346703b98068e/html5/thumbnails/27.jpg)
DOSAGE PUNCH
DOSAGE TUBE
DOSAGE BLOCK
CAPSULE BODY
BUSHING
DOSAGE HOPPER
COMPRESSION FILLING
![Page 28: Capsule Filling MC Validation](https://reader033.vdocuments.mx/reader033/viewer/2022061504/55cf8f03550346703b98068e/html5/thumbnails/28.jpg)
DOSAGE PUNCH
DOSAGE TUBE
DOSAGE BLOCK
CAPSULE BODY
BUSHING
DOSAGE HOPPER
![Page 29: Capsule Filling MC Validation](https://reader033.vdocuments.mx/reader033/viewer/2022061504/55cf8f03550346703b98068e/html5/thumbnails/29.jpg)
VACUUM
DOSAGE TROUGH
DOSAGE TUBE
FORMATION OF PLUG
VACCUM FILLING METHOD
![Page 30: Capsule Filling MC Validation](https://reader033.vdocuments.mx/reader033/viewer/2022061504/55cf8f03550346703b98068e/html5/thumbnails/30.jpg)
PLASTIC PISTON WITH FILTER
![Page 31: Capsule Filling MC Validation](https://reader033.vdocuments.mx/reader033/viewer/2022061504/55cf8f03550346703b98068e/html5/thumbnails/31.jpg)
GELATIN TANK
SPREATER BOX
COOLING DRUM
PRODUCT MATERIAL TANK
INJECTION WEDGE
RIBBON
CONVEYER BELT
PRODUCT PUMP
DIE ROLL
SOFT GELATIN CAPSULE FILLING
![Page 32: Capsule Filling MC Validation](https://reader033.vdocuments.mx/reader033/viewer/2022061504/55cf8f03550346703b98068e/html5/thumbnails/32.jpg)
GELATIN TANK
SPREATER BOX
COOLING DRUM
PRODUCT MATERIAL TANK
INJECTION WEDGE
RIBBON
CONVEYER BELT
PRODUCT PUMP
DIE ROLL
![Page 33: Capsule Filling MC Validation](https://reader033.vdocuments.mx/reader033/viewer/2022061504/55cf8f03550346703b98068e/html5/thumbnails/33.jpg)
GELATIN TANK
SPREATER BOX
COOLING DRUM
PRODUCT MATERIAL TANK
INJECTION WEDGE
RIBBON
CONVEYER BELT
PRODUCT PUMP
DIE ROLL
![Page 34: Capsule Filling MC Validation](https://reader033.vdocuments.mx/reader033/viewer/2022061504/55cf8f03550346703b98068e/html5/thumbnails/34.jpg)
FOR HARD GELATIN CAPSULE:
CONTROL PARAMAETERS
SR NO. VARIABLE RESPONSE
1. MACHINE SPEEDDOSE UNIFORMITY
2. BED HEIGHTWEIGHT VARIATION
3. COMPACTION PRESSUREAPPEARANCE/ LENGTH
4. DOSING PRESSURECONTENT UNIFORMITY
5. CLOSING VOLUME
A. DISSOLUTIONB. MICROBIAL COUNTC. MOISTURE CONTENT (BRITTLENESS)
![Page 35: Capsule Filling MC Validation](https://reader033.vdocuments.mx/reader033/viewer/2022061504/55cf8f03550346703b98068e/html5/thumbnails/35.jpg)
FOR SOFT GELATIN CAPSULE:
CONTROL PARAMAETERS
SR NO. VARIABLE RESPONSE
1. SPEED OF DIE ROTATION
ELEGANCE/ COLOR
2. TEMPERATURE OF GELATIN CAPSULE FILL WEIGHT
3. RIBBON THICKNESSCAPSULE SHELL WEIGHT
4.TEMPERATURE AND
HUMIDITY OF PROCESSING AREA
A. CAPSULE WALL THICKNESSB. ASSAY AND CONTENT UNIFORMITYC. DISSOLUTION D. MOISTURE CONTENT E. LEAK TEST
![Page 36: Capsule Filling MC Validation](https://reader033.vdocuments.mx/reader033/viewer/2022061504/55cf8f03550346703b98068e/html5/thumbnails/36.jpg)
Basic document that is root for all validation and qualification activities The goal of working out user requirement specifications is to document the needs of the manufacturing department
A well prepared URS is the key to project success Project without detailed URS have a tendency to demand lots of change later on thus increase cost and start up time
4. USER REQUIREMENTS
SPECIFICATIONS (URS)
![Page 37: Capsule Filling MC Validation](https://reader033.vdocuments.mx/reader033/viewer/2022061504/55cf8f03550346703b98068e/html5/thumbnails/37.jpg)
For evaluation of URS, the coordinated approach among production, QA, engineering units of the pharmaceutical company is required
Some companies even use the services of external resources to create a URS
The key aspects of any URS is to generate a document detailing all the GMP requirements the technical system has to fulfill.
A detail URS will result in a better and more competitive offer for the technical system.
Without comprehensive URS, a pharmaceutical company cannot get a clear understanding of supplier and may be led to a wrong decision.
![Page 38: Capsule Filling MC Validation](https://reader033.vdocuments.mx/reader033/viewer/2022061504/55cf8f03550346703b98068e/html5/thumbnails/38.jpg)
1. Operation: Production Speed ______ Capsules/ min2. Capsule will be filled to the target weight
± ______%3. The Machine Shall not experience more than
______ % downtime at the production speed, during 8 hour production run
4. Product contact part: Shall be constructed from material acceptable to the product
Certificates for Material, Weld and Finish shall be defined.
Products Contact Part shall be Defined
OPERATIONAL REQUIREMENTS
![Page 39: Capsule Filling MC Validation](https://reader033.vdocuments.mx/reader033/viewer/2022061504/55cf8f03550346703b98068e/html5/thumbnails/39.jpg)
5. Power Failure and Recovery: On Power Failure the System shall fall in “SAFE STATE”6. On Power Restoration, the System shall not
restart without Operator or Communication Link- input7. Buttons shall be supplied within the reach of the Operator at the Normal Operator Station Protective Hood Operation : Machine must STOP if Hood remains open Acoustic Signal Operation : When Error Occurs the Buzzer Sounds Protective Guard Operation : When Protective Guards are removed Machine Stops7. Control Function Test : Main and
Vacuum Motor Rotation
Direction
Emergency STOP :
![Page 40: Capsule Filling MC Validation](https://reader033.vdocuments.mx/reader033/viewer/2022061504/55cf8f03550346703b98068e/html5/thumbnails/40.jpg)
ALARM OR WARNINGS:
SR NO. ALARMS OR WARNINGS IMMEDIATE OPERATOR/ ALERT
1. EMERGENCY STOP X
2. PROTECTIVE GUARDS NOT IN PLACE X
3. NO CAPSULES X
4. LOW PRODUCT LEVEL X
5. CONTROL POWER FAULT X
![Page 41: Capsule Filling MC Validation](https://reader033.vdocuments.mx/reader033/viewer/2022061504/55cf8f03550346703b98068e/html5/thumbnails/41.jpg)
DATA AND SECUIRTY:
“Controls provided with a data collection system intended for use in the manufacture of pharmaceutical products shall comply with 21 CFR, Part 11 of the FDA cGMP regulations.”
DATA COLLECTION:Data required for collection
1. Machine rate2. Alarms and warnings.3. System status (e.g. “off,” “ on,” “standby” states, etc.) Other (specify)
![Page 42: Capsule Filling MC Validation](https://reader033.vdocuments.mx/reader033/viewer/2022061504/55cf8f03550346703b98068e/html5/thumbnails/42.jpg)
ENVIRONMENT:
1. PHYSICAL CONDITION The CAPSULE FILLER needs to be installed in an environment in
with Temperature range between ______ to ______ ˚F or ˚C and Relative Humidity between _____ to _____ %
Vibration Levels and Electromagnetic Interference Levels: (a) Negligible (b) Others(specify)
2. CLEANING CONDITION The Equipment will be Cleaned Utilizing following
Compounds/ Detergents/ Cleaning Agents: _____________ It is anticipated the equipment will be cleaned on a _______
basis
![Page 43: Capsule Filling MC Validation](https://reader033.vdocuments.mx/reader033/viewer/2022061504/55cf8f03550346703b98068e/html5/thumbnails/43.jpg)
The Installation Qualification(IQ) shall confirm detail from:
1. The Equipment Specifications2. Equipment Purchase Order3. cGMP Guidelines and Requirements
It has to be Ensured that the Equipment has been installed as specified by the vendor
INSTALLATION QUALIFICATION
![Page 44: Capsule Filling MC Validation](https://reader033.vdocuments.mx/reader033/viewer/2022061504/55cf8f03550346703b98068e/html5/thumbnails/44.jpg)
PURCHASE DETAILS:Check the Following and should be as per Purchase Order:
Purchase Order Number and Its Date The Accessories and Its Spare Parts Delivery Period Supplier, Manufacturer Name and Address
NOTE: Any Deviation if Observed needs to be reported to the Manufacturer or Supplier
![Page 45: Capsule Filling MC Validation](https://reader033.vdocuments.mx/reader033/viewer/2022061504/55cf8f03550346703b98068e/html5/thumbnails/45.jpg)
DETAILS OF THE EQUIPMENT:
Equipment name, make & model no. shall be recorded e.g. (i) Name: CapsulCN Capsule Filler (ii) Model No.: 2GM In-house identification no. shall be recorded Location for installation shall be checked Utilities required shall be listed down A detailed specification must be written which highlight those parts of machine that are in product contact Where stirring devices or augers are used to ensure homogeneity and improve flow then specification of these parts must be checked
![Page 46: Capsule Filling MC Validation](https://reader033.vdocuments.mx/reader033/viewer/2022061504/55cf8f03550346703b98068e/html5/thumbnails/46.jpg)
DETAILS OF THE EQUIPMENT:
Equipment name, make & model no. shall be recorded In-house identification no. shall be recorded e.g. INH ID No.: 4052 Location for installation shall be checked Utilities required shall be listed down A detailed specification must be written which highlight those parts of machine that are in product contact Where stirring devices or augers are used to ensure homogeneity and improve flow then specification of these parts must be checked
![Page 47: Capsule Filling MC Validation](https://reader033.vdocuments.mx/reader033/viewer/2022061504/55cf8f03550346703b98068e/html5/thumbnails/47.jpg)
DETAILS OF THE EQUIPMENT:
Equipment name, make & model no. shall be recorded In-house identification no. shall be recorded Location for installation shall be checked e.g. Location: Room 147 Utilities required shall be listed down A detailed specification must be written which highlight those parts of machine that are in product contact Where stirring devices or augers are used to ensure homogeneity and improve flow then specification of these parts must be checked
![Page 48: Capsule Filling MC Validation](https://reader033.vdocuments.mx/reader033/viewer/2022061504/55cf8f03550346703b98068e/html5/thumbnails/48.jpg)
DETAILS OF THE EQUIPMENT:
Equipment name, make & model no. shall be recorded In-house identification no. shall be recorded Location for installation shall be checked Utilities required shall be listed down e.g. Electrical Utilities must meet all electrical codes Volts: 480 ± 10% Amps: Motor= 6.5, Vacuum= 1.7 Compressed Air: > 87 psig Power Supply Source, Breaker Box, Wire Number etc A detailed specification must be written which highlight those parts of machine that are in product contact Where stirring devices or augers are used to ensure homogeneity and improve flow then specification of these parts must be checked
![Page 49: Capsule Filling MC Validation](https://reader033.vdocuments.mx/reader033/viewer/2022061504/55cf8f03550346703b98068e/html5/thumbnails/49.jpg)
DETAILS OF THE EQUIPMENT:
Equipment name, make & model no. shall be recorded In-house identification no. shall be recorded Location for installation shall be checked Utilities required shall be listed down A detailed specification must be written which highlight those parts of machine that are in product contact e.g. Machine Parts of Filling, Control Cabinet Software etc Where stirring devices or augers are used to ensure homogeneity and improve flow then specification of these parts must be checked
![Page 50: Capsule Filling MC Validation](https://reader033.vdocuments.mx/reader033/viewer/2022061504/55cf8f03550346703b98068e/html5/thumbnails/50.jpg)
DETAILS OF THE EQUIPMENT:
Equipment name, make & model no. shall be recorded In-house identification no. shall be recorded Location for installation shall be checked Utilities required shall be listed down A detailed specification must be written which highlight those parts of machine that are in product contact Where stirring devices or augers are used to ensure homogeneity and improve flow then specification of these parts must be checked e.g. Lubricants Where Used: Gear and Motor Reducers
![Page 51: Capsule Filling MC Validation](https://reader033.vdocuments.mx/reader033/viewer/2022061504/55cf8f03550346703b98068e/html5/thumbnails/51.jpg)
ACCEPTANCE CRITERIA FOR IQ:
Fulfill the selection criteria & its purpose of Application The equipment shall be as per purchase order Accessories received shall be as per purchase order Should meet pre-selected design parameters Manufacturer/supplier shall provide complete equipment manual Material of construction shall be as per purchase order
![Page 52: Capsule Filling MC Validation](https://reader033.vdocuments.mx/reader033/viewer/2022061504/55cf8f03550346703b98068e/html5/thumbnails/52.jpg)
Before initiating OQ ensure SOPs for Operating and Cleaning of Capsule Filling Machine are available
PROCEDURE:
1. Check all the dynamic attributes of the capsule filler conform to the required specifications2. Initiate the actual operation of the equipment to ensure that machine is operate within the desired rate of output.3. The operation of indicators, controls and alarms is verified4. Oil leaks that could contaminate the process are observed
OPERATIONAL QUALIFICATION
![Page 53: Capsule Filling MC Validation](https://reader033.vdocuments.mx/reader033/viewer/2022061504/55cf8f03550346703b98068e/html5/thumbnails/53.jpg)
SET-I CAPSULE FILL
CHECK
SET-II CAPSULE FILL
CHECK
SET-III CAPSULE FILL
CHECK
OPERATION CHECK FOR CAPSULE FILLING
![Page 54: Capsule Filling MC Validation](https://reader033.vdocuments.mx/reader033/viewer/2022061504/55cf8f03550346703b98068e/html5/thumbnails/54.jpg)
ACCEPTANCE CRITERIA FOR OQ:
All operating inputs provided on the equipment when tested shall-successfully comply -Meet Tolerance Limit The Equipment should successfully perform when operated as per SOP Critical alarm/indicators provided on the equipment- calibrated The Equipment when operated shall not - produce abnormal sound - show any discrepancy in its smooth operation.
![Page 55: Capsule Filling MC Validation](https://reader033.vdocuments.mx/reader033/viewer/2022061504/55cf8f03550346703b98068e/html5/thumbnails/55.jpg)
PQ activities demonstrates and documents that the equipment is able to perform its intended functions within the variable process limits for a specific product
Acceptance criteria are developed according to the regulatory requirements and production parameters
To ensure that the quality and purity of the product is maintained
The PQ's require replicate testing; triplicate testing as the generally accepted minimum.
The PQ will also test the extremes of the operation, or the peak load conditions, but it does not include testing to failure.
PERFORMANCE QUALIFICATION
![Page 56: Capsule Filling MC Validation](https://reader033.vdocuments.mx/reader033/viewer/2022061504/55cf8f03550346703b98068e/html5/thumbnails/56.jpg)
PROCEDURE:
1. The accuracy and precision of placebo powder fill will be evaluated for each capsule size that will be used in normal production
2. Record the number of damaged capsules
3. Capsules from throughout the lot/different batches should be tested for weight uniformity
4. Capsules from throughout the lot/different batches should be tested for blend content uniformity
5. Production speed i.e. capsule per minute should be evaluated
![Page 57: Capsule Filling MC Validation](https://reader033.vdocuments.mx/reader033/viewer/2022061504/55cf8f03550346703b98068e/html5/thumbnails/57.jpg)
Q-1 Discuss Criteria for Validation of Tablet Machine and Capsule Filling Machine - 5 marks May 2012Q-2 Describe Unit Operation along with their Process Variables for Hard Gelatin Capsules
QUESTIONS ASKED IN GTU????
![Page 58: Capsule Filling MC Validation](https://reader033.vdocuments.mx/reader033/viewer/2022061504/55cf8f03550346703b98068e/html5/thumbnails/58.jpg)
6.REFERENCES
1. Nash RA. And Wachter AH. “Pharmaceutical process
validation”; 3rd edition ; Basel (NY): Marcel Dekker
Inc , 1993, Pg No. 83-1102. Mehta RM. “Dispensing Pharmacy”,
3rd Edition; Vallabh Prakashan, 2008, Pg No. 108-145 3. Syed Imtiaz Haider, “Pharmaceutical
Master Validation Plan”, St. Luicepress, Pg No.
114, 119, 1204. PP Sharma, “Validation in
Pharmaceutical Industry”, First Edition, Vandana
Publication, 2008, Pg No. 83-99
![Page 59: Capsule Filling MC Validation](https://reader033.vdocuments.mx/reader033/viewer/2022061504/55cf8f03550346703b98068e/html5/thumbnails/59.jpg)
4. International conference on harmonization of
technical requirements for registration of pharmaceuticals for human use, ICH harmonised tripartite guideline. “Good manufacturing practice guide for active pharmaceutical ingredients” Q7, current step 4 version.2000
5. Graham C. Cole, : The Design and Operation of a Facility for Filling Hard Gelatin Capsules”, Middle Green, Bringham- ARTICLE
6. Leon Lachman, “The Theory and Practice of Industrial Pharmacy”, Special Indian Edition, 2009, Pg No. 374-412
![Page 60: Capsule Filling MC Validation](https://reader033.vdocuments.mx/reader033/viewer/2022061504/55cf8f03550346703b98068e/html5/thumbnails/60.jpg)
QUALITY NEEDS TO BE BUILT INTO THE PRODUCT
GARVIN’S 8 DIMENSIONS OF QUALITY:
1. PERFORMANCE2. SECONDARY FEATURES3. DURABILITY4. AESTHETICS5. PERCEIVED QUALITY6. SERVICES7. CONFORMANCE8. RELIABILITY
THANK