Download - BUS FIRE SAFETY - UNECE
![Page 1: BUS FIRE SAFETY - UNECE](https://reader031.vdocuments.mx/reader031/viewer/2022012507/6183994d1792fc33510de362/html5/thumbnails/1.jpg)
RISE Research Institutes of Sweden
BUS FIRE SAFETY
2018-01-29
Michael Försth
Fire Research
![Page 2: BUS FIRE SAFETY - UNECE](https://reader031.vdocuments.mx/reader031/viewer/2022012507/6183994d1792fc33510de362/html5/thumbnails/2.jpg)
The RISE institutes Innventia, SP and Swedish ICT have merged in order to become a stronger research and innovation partner for businesses and society.
2
Three have become
one - RISE
43 %
![Page 3: BUS FIRE SAFETY - UNECE](https://reader031.vdocuments.mx/reader031/viewer/2022012507/6183994d1792fc33510de362/html5/thumbnails/3.jpg)
3
2016 RISE had a turnover of just ≈ 250 MEuro
2 200 employees, 30 % with a PhD
Facts about RISE
![Page 4: BUS FIRE SAFETY - UNECE](https://reader031.vdocuments.mx/reader031/viewer/2022012507/6183994d1792fc33510de362/html5/thumbnails/4.jpg)
Staff: About 165 comprising 4 professors, 21 PhD:s, 10 PhD students, MSc:s, engineers and administrative personnel
4
RISE Fire Research
Sweden (Borås laboratory) Norway (Trondheim)
![Page 5: BUS FIRE SAFETY - UNECE](https://reader031.vdocuments.mx/reader031/viewer/2022012507/6183994d1792fc33510de362/html5/thumbnails/5.jpg)
5
Outline
Bus fires background
Recent fire safety development
Interior materials
Fire suppression
Fire detection
Prevention/Safety management
Ideas for further development
Toxicity
Fire detection
Protection of energy storage
![Page 6: BUS FIRE SAFETY - UNECE](https://reader031.vdocuments.mx/reader031/viewer/2022012507/6183994d1792fc33510de362/html5/thumbnails/6.jpg)
6
Outline
Bus fires background
Recent fire safety development
Interior materials
Fire suppression
Fire detection
Prevention/Safety management
Ideas for further development
Toxicity
Fire detection
Protection of energy storage
![Page 7: BUS FIRE SAFETY - UNECE](https://reader031.vdocuments.mx/reader031/viewer/2022012507/6183994d1792fc33510de362/html5/thumbnails/7.jpg)
Background
In Sweden fires are reported for 1% of buses annually, and 10% of all buses are involved in a fire during their service life.
This means that, in percentage, about 5-10 times as many buses catch fire as do heavy goods vehicles.
7
![Page 8: BUS FIRE SAFETY - UNECE](https://reader031.vdocuments.mx/reader031/viewer/2022012507/6183994d1792fc33510de362/html5/thumbnails/8.jpg)
Background
71%
24%
4%
1%
Start of bus fires 2005-2013 in Sweden, known cases
Engine room
Wheel well
Interior
Other
8
![Page 9: BUS FIRE SAFETY - UNECE](https://reader031.vdocuments.mx/reader031/viewer/2022012507/6183994d1792fc33510de362/html5/thumbnails/9.jpg)
Background
Before 2004:
Approximately six to seven complete burnouts of buses each year in Sweden due to fires that started
in the engine compartment.
2004:
Swedish insurance companies requested that all buses should be equipped with an approved fire
suppression system in the engine compartment.
2004-2012:
No complete burnouts of buses due to such fires
Regulations and legislation works!
9
![Page 10: BUS FIRE SAFETY - UNECE](https://reader031.vdocuments.mx/reader031/viewer/2022012507/6183994d1792fc33510de362/html5/thumbnails/10.jpg)
www.bam.de
BUS FIRE SAFETY – INTERIOR MATERIALS Anja Hofmann-Böllinghaus
24.01.2018
![Page 11: BUS FIRE SAFETY - UNECE](https://reader031.vdocuments.mx/reader031/viewer/2022012507/6183994d1792fc33510de362/html5/thumbnails/11.jpg)
Fire causes
Fire origin: in 80 % the engine area
11 FAM 28. – 30.1.2013 San Francisco Dr. Anja Hofmann
Bildquelle: dpa (2009)
Bildquelle: DEKRA (2010)
Electrical
failure
Wheels
Bildquelle: NIST (2007)
![Page 12: BUS FIRE SAFETY - UNECE](https://reader031.vdocuments.mx/reader031/viewer/2022012507/6183994d1792fc33510de362/html5/thumbnails/12.jpg)
Statistics
12
Bus fires in Germany:
- every second/third day (own web search)
- 161 fires in 2009 in busses with insurance (GDV)
- app. 350 – 400 Busse per year (PUPA 2010)
- Sweden: 80 busses (Swedish Transport Agency)
- USA: 0,8% per 100.000 busses (GBH International)
FAM 28. – 30.1.2013 San Francisco Dr. Anja Hofmann
- internal investigation of a German bus association: 1 % of the busses
per year
![Page 13: BUS FIRE SAFETY - UNECE](https://reader031.vdocuments.mx/reader031/viewer/2022012507/6183994d1792fc33510de362/html5/thumbnails/13.jpg)
Fire safety standards
•ISO 3795 (International) •DIN 75200 (Germany) •ST 18-502 (France) •BS AU 169 (UK) •JIS D 1201 (Japan)
•GS 97038 (BMW) •DBL 5307 (Daimler) •FLTM-BN 24-2 (Ford) •GM 6090 M (GM) •MES DF 050D (Mazda) •ES–X60410 (Mitsubishi) •PTL 8501 (Porsche) •D45 1333; (Renault) •STD 5031,1 (Volvo) •TL 1010 (VW)
Fire safety for buses: EU guideline 95/28/EG
Fire tests: FMVSS 302
Worldwide harmonized standard
FMVSS 302 was developed in the 1960ties
13 FAM 28. – 30.1.2013 San Francisco Dr. Anja Hofmann
![Page 14: BUS FIRE SAFETY - UNECE](https://reader031.vdocuments.mx/reader031/viewer/2022012507/6183994d1792fc33510de362/html5/thumbnails/14.jpg)
Operation conditions of buses and trains are widely comparable
Bus interior materials were tested according to CEN/TS 45545-2
Bildquelle: http://spheric.de/bvg-perspektive (08.12.2011) City buses and trams
Coaches and long distance trains
BZ (2012) www.ppp.co.at (2010)
: BVG (2011) www.mannheim.org (2012)
Operation conditions
FAM 28. – 30.1.2013 San Francisco Dr. Anja Hofmann
![Page 15: BUS FIRE SAFETY - UNECE](https://reader031.vdocuments.mx/reader031/viewer/2022012507/6183994d1792fc33510de362/html5/thumbnails/15.jpg)
In U.S.A. 31 vehicle fires are reported per hour and these are responsible for around 300
deaths. These fires are involved in 12 % of fire deaths.
Trends indicate that the survivable collision energy will continue to increase and, at the
same time, the probability of post-crash fires rises with the collision energy
As crashes are expected to become more survivable with advanced technology, fire events might become even more relevant
Post-collision fires
![Page 16: BUS FIRE SAFETY - UNECE](https://reader031.vdocuments.mx/reader031/viewer/2022012507/6183994d1792fc33510de362/html5/thumbnails/16.jpg)
16
Outline
Bus fires background
Recent fire safety development
Interior materials
Fire suppression
Fire detection
Prevention/Safety management
Ideas for further development
Toxicity
Fire detection
Protection of energy storage
![Page 17: BUS FIRE SAFETY - UNECE](https://reader031.vdocuments.mx/reader031/viewer/2022012507/6183994d1792fc33510de362/html5/thumbnails/17.jpg)
Ensuring fire safety in buses Michael Försth,
Asbjørn Hagerupsen, Jan Petzäll
Informal document No. GRSG-95-xx,
agenda item 4
Belgium 2003
11 dead
US Texas 2005
24 dead
Poland 2005
12 dead
Switzerland 2006
3 dead
![Page 18: BUS FIRE SAFETY - UNECE](https://reader031.vdocuments.mx/reader031/viewer/2022012507/6183994d1792fc33510de362/html5/thumbnails/18.jpg)
Problem: Regulation No. 118 – burning rate test
(See documents GRSG 94-33, 94-17, 93-15, 92-18, 91-19, 90-32, 90-16, 89-33, 89-23, and 88-21)
Test of horizontal flame spread (ISO 3795, FMVSS 302)
The test only considers horizontal flame propagation, and contains additional technical shortcomings such
as interrupted combustion when test object burns too fast and falls apart.
![Page 19: BUS FIRE SAFETY - UNECE](https://reader031.vdocuments.mx/reader031/viewer/2022012507/6183994d1792fc33510de362/html5/thumbnails/19.jpg)
Are matches fire safe?
![Page 20: BUS FIRE SAFETY - UNECE](https://reader031.vdocuments.mx/reader031/viewer/2022012507/6183994d1792fc33510de362/html5/thumbnails/20.jpg)
Solution: Proposed fire tests for Reg. No. 118
Use of four established ISO/CEN tests, applied world-wide:
1. Flame spread for surface linings
2. Flame spread for floorings
3. Test for production of smoke and toxic gases
4. Measurement of heat release from a seat
These are established test methods in transportation (e.g. trains – EN 45545-2)
Complying materials exist on the market
![Page 21: BUS FIRE SAFETY - UNECE](https://reader031.vdocuments.mx/reader031/viewer/2022012507/6183994d1792fc33510de362/html5/thumbnails/21.jpg)
1. Proposed alternative test for Flame Spread
Flame spread test for surface linings
Criterion for trains: Critical Flux at Extinguishment ≥ 20 kW/m2
![Page 22: BUS FIRE SAFETY - UNECE](https://reader031.vdocuments.mx/reader031/viewer/2022012507/6183994d1792fc33510de362/html5/thumbnails/22.jpg)
2. Proposed alternative test for Flame Spread
European harmonised flooring test
Criterion: Critical Heat Flux at extinguishment ≥ 6 kW/m2. Same as for floors on trains.
![Page 23: BUS FIRE SAFETY - UNECE](https://reader031.vdocuments.mx/reader031/viewer/2022012507/6183994d1792fc33510de362/html5/thumbnails/23.jpg)
3. Proposed test for Smoke and Toxic Gas production
Smoke test and analysis of toxic gases
Criteria: Requirements on smoke density and concentration of toxic species.
![Page 24: BUS FIRE SAFETY - UNECE](https://reader031.vdocuments.mx/reader031/viewer/2022012507/6183994d1792fc33510de362/html5/thumbnails/24.jpg)
Measurement of heat release
Criterion: Maximum Average Rate of Heat Emission < 50 kW. Same as for seats on trains.
4. Proposed test for Seats
![Page 25: BUS FIRE SAFETY - UNECE](https://reader031.vdocuments.mx/reader031/viewer/2022012507/6183994d1792fc33510de362/html5/thumbnails/25.jpg)
before fire after 20 sec after 2 min after fire
Bus upholstered seat
after 20 min after 5 min after fire after 20 sec
Railway upholstered seat
Observations
![Page 26: BUS FIRE SAFETY - UNECE](https://reader031.vdocuments.mx/reader031/viewer/2022012507/6183994d1792fc33510de362/html5/thumbnails/26.jpg)
Comparison
ProdNo. ISO 3795 / FMVSS 302 ISO 6941
ISO5658-2 / SSoF
1 pass fail fail
2 pass pass pass
3 fail pass fail
4 pass pass fail
5 pass fail fail
6 pass fail fail
7 pass fail pass
8 pass fail pass
9 pass pass pass
10 pass pass pass
11 pass fail fail
12 pass fail fail
13 pass fail fail
14 pass pass fail
15 pass pass pass
16 pass pass pass
17 pass pass pass
26
![Page 27: BUS FIRE SAFETY - UNECE](https://reader031.vdocuments.mx/reader031/viewer/2022012507/6183994d1792fc33510de362/html5/thumbnails/27.jpg)
Conclusions
• Lack of requirements for an acceptable level of fire safety for interior materials. (Replacement of horizontal burning rate test with vertical burning rate test was however a step in the right direction.)
• This can be accomplished using established international fire tests, already used for train interiors. Therefore complying materials already exist on the market
• A proposed solution was presented in draft amendment to Reg. No. 118 in informal document GRSG 95-19.
![Page 28: BUS FIRE SAFETY - UNECE](https://reader031.vdocuments.mx/reader031/viewer/2022012507/6183994d1792fc33510de362/html5/thumbnails/28.jpg)
28
Outline
Bus fires background
Recent fire safety development
Interior materials
Fire suppression
Fire detection
Prevention/Safety management
Ideas for further development
Toxicity
Fire detection
Protection of energy storage
![Page 29: BUS FIRE SAFETY - UNECE](https://reader031.vdocuments.mx/reader031/viewer/2022012507/6183994d1792fc33510de362/html5/thumbnails/29.jpg)
Automatic fire suppression systems for engine
compartments in coaches and buses: regulations and
standards.
Presentation at GRSG 98, May 3-7, 2010 Asbjørn Hagerupsen1, Jan Petzäll2 and Michael Försth3 1Norwegian Public Roads Administration 2Swedish Transport Agency 3SP Technical Research Institute of Sweden
![Page 30: BUS FIRE SAFETY - UNECE](https://reader031.vdocuments.mx/reader031/viewer/2022012507/6183994d1792fc33510de362/html5/thumbnails/30.jpg)
Background
Before 2004:
Approximately six to seven complete burnouts of buses each year in Sweden due to fires that started
in the engine compartment.
2004:
Swedish insurance companies requested that all buses should be equipped with an approved fire
suppression system in the engine compartment.
2004-2012:
No complete burnouts of buses due to such fires
Regulations and legislation works!
30 Amendment of Regulation No. 107
![Page 31: BUS FIRE SAFETY - UNECE](https://reader031.vdocuments.mx/reader031/viewer/2022012507/6183994d1792fc33510de362/html5/thumbnails/31.jpg)
SP Report 2008:41
![Page 32: BUS FIRE SAFETY - UNECE](https://reader031.vdocuments.mx/reader031/viewer/2022012507/6183994d1792fc33510de362/html5/thumbnails/32.jpg)
New approach: Combine repeatable test methods with realistic fire scenarios
Identified properties which are important to include in the test:
Complex geometry with many obstructions
High air flow
Multiple fire locations
Different fire scenarios
Hot surfaces with re-ignition potential
Two parts of the project:
Fire suppression performance (finalized in 2013) Amendment of Regulation No. 107
Fire detection capability (finalized 2016)
32
Test method – a new approach
![Page 33: BUS FIRE SAFETY - UNECE](https://reader031.vdocuments.mx/reader031/viewer/2022012507/6183994d1792fc33510de362/html5/thumbnails/33.jpg)
33
Outline
Bus fires background
Recent fire safety development
Interior materials
Fire suppression
Fire detection
Prevention/Safety management
Ideas for further development
Toxicity
Fire detection
Protection of energy storage
![Page 34: BUS FIRE SAFETY - UNECE](https://reader031.vdocuments.mx/reader031/viewer/2022012507/6183994d1792fc33510de362/html5/thumbnails/34.jpg)
Test method for fire detection systems installed in engine compartments of heavy vehicles
34
SP method 5320 – testing of fire detection systems
![Page 35: BUS FIRE SAFETY - UNECE](https://reader031.vdocuments.mx/reader031/viewer/2022012507/6183994d1792fc33510de362/html5/thumbnails/35.jpg)
35
Outline
Bus fires background
Recent fire safety development
Interior materials
Fire suppression
Fire detection
Prevention/Safety management
Ideas for further development
Toxicity
Fire detection
Protection of energy storage
![Page 36: BUS FIRE SAFETY - UNECE](https://reader031.vdocuments.mx/reader031/viewer/2022012507/6183994d1792fc33510de362/html5/thumbnails/36.jpg)
36
Preventive fire safety
![Page 37: BUS FIRE SAFETY - UNECE](https://reader031.vdocuments.mx/reader031/viewer/2022012507/6183994d1792fc33510de362/html5/thumbnails/37.jpg)
P-certification for vehicle manufacturers, operators and service centers (workshops) with regard to fire safety
vehicle manufacturer
operator
workshop
37
Safety Management with regard to fire
![Page 38: BUS FIRE SAFETY - UNECE](https://reader031.vdocuments.mx/reader031/viewer/2022012507/6183994d1792fc33510de362/html5/thumbnails/38.jpg)
SPCR 191 - Certification rules for operators with respect to vehicle fire safety
Co-operation with IRU
38
SPCR - Certification rules
operator
![Page 39: BUS FIRE SAFETY - UNECE](https://reader031.vdocuments.mx/reader031/viewer/2022012507/6183994d1792fc33510de362/html5/thumbnails/39.jpg)
39
Outline
Bus fires background
Recent fire safety development
Interior materials
Fire suppression
Fire detection
Prevention/Safety management
Ideas for further development
Toxicity
Fire detection
Protection of energy storage
![Page 40: BUS FIRE SAFETY - UNECE](https://reader031.vdocuments.mx/reader031/viewer/2022012507/6183994d1792fc33510de362/html5/thumbnails/40.jpg)
Gap analysis
40
71%
24%
4%
1%
Engine room
Wheel well
Interior
Other
Prevention, detection,
suppression
Prevention, detection,
fire hardening, prolonging tenability
conditions in passanger compartment
![Page 41: BUS FIRE SAFETY - UNECE](https://reader031.vdocuments.mx/reader031/viewer/2022012507/6183994d1792fc33510de362/html5/thumbnails/41.jpg)
41
Outline
Bus fires background
Recent fire safety development
Interior materials
Fire suppression
Fire detection
Prevention/Safety management
Ideas for further development
Toxicity
Fire detection
Protection of energy storage
![Page 42: BUS FIRE SAFETY - UNECE](https://reader031.vdocuments.mx/reader031/viewer/2022012507/6183994d1792fc33510de362/html5/thumbnails/42.jpg)
42
Toxicity
Focus on the production of toxic
gases, starting from the side of the
expected fire.
![Page 43: BUS FIRE SAFETY - UNECE](https://reader031.vdocuments.mx/reader031/viewer/2022012507/6183994d1792fc33510de362/html5/thumbnails/43.jpg)
43
Outline
Bus fires background
Recent fire safety development
Interior materials
Fire suppression
Fire detection
Prevention/Safety management
Ideas for further development
Toxicity
Fire detection
Protection of energy storage
![Page 44: BUS FIRE SAFETY - UNECE](https://reader031.vdocuments.mx/reader031/viewer/2022012507/6183994d1792fc33510de362/html5/thumbnails/44.jpg)
44
Detection
Regulation No 107
![Page 45: BUS FIRE SAFETY - UNECE](https://reader031.vdocuments.mx/reader031/viewer/2022012507/6183994d1792fc33510de362/html5/thumbnails/45.jpg)
45
Outline
Bus fires background
Recent fire safety development
Interior materials
Fire suppression
Fire detection
Prevention/Safety management
Ideas for further development
Toxicity
Fire detection
Protection of energy storage
![Page 46: BUS FIRE SAFETY - UNECE](https://reader031.vdocuments.mx/reader031/viewer/2022012507/6183994d1792fc33510de362/html5/thumbnails/46.jpg)
In U.S.A. 31 vehicle fires are reported per hour and these are responsible for around 300
deaths. These fires are involved in 12 % of fire deaths.
Trends indicate that the survivable collision energy will continue to increase and, at the
same time, the probability of post-crash fires rises with the collision energy
As crashes are expected to become more survivable with advanced technology, fire events might become even more relevant
Post-collision fires
Requirement for improved protection of energy storage (e.g. fuel tanks)
![Page 47: BUS FIRE SAFETY - UNECE](https://reader031.vdocuments.mx/reader031/viewer/2022012507/6183994d1792fc33510de362/html5/thumbnails/47.jpg)
Transportstyrelsen (Sweden)
Statens vegvesen (Norway)
FFI (Strategic vehicle research and innovation, Sweden)
BAM
SP/RISE
47
Acknowledgements
![Page 48: BUS FIRE SAFETY - UNECE](https://reader031.vdocuments.mx/reader031/viewer/2022012507/6183994d1792fc33510de362/html5/thumbnails/48.jpg)
RISE Research Institutes of Sweden
THANK YOU, QUESTIONS?
Michael Försth
+46 – (0)10- 516 52 33
Fire Research