BSC6900 Hardware Description
BSC6900V900R011/R012
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 2
Upon completion of this course, you
will be able to:
Master the BSC hardware
structure ;
Master the BSC board function
and specifications.
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 3
References
《 BSC Product Documentation 》
《 BSC Hardware Description 》
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 4
Chapter 1 Physical StructureChapter 1 Physical Structure
Chapter 2 Cabinet Chapter 2 Cabinet
Chapter 3 Cable ConnectionsChapter 3 Cable Connections
Chapter 4 Components of the CabinetChapter 4 Components of the Cabinet
Chapter 5 SubracksChapter 5 Subracks
Chapter 6 BoardsChapter 6 Boards
Chapter 7 CablesChapter 7 Cables
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 5
Physical Structure
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 6
Chapter 1 Physical StructureChapter 1 Physical Structure
Chapter 2 CabinetChapter 2 Cabinet
Chapter 3 Cable ConnectionsChapter 3 Cable Connections
Chapter 4 Components of the CabinetChapter 4 Components of the Cabinet
Chapter 5 SubracksChapter 5 Subracks
Chapter 6 BoardsChapter 6 Boards
Chapter 7 CablesChapter 7 Cables
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 7
Cabinet
Appearance of the CabinetAppearance of the Cabinet
Single-door Cabinet Double-door Cabinet
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 8
Cabinet
Classificatins of the CabinetsClassificatins of the Cabinets
MPROnly one MPR is configured in the BSC6900.
EPRThe number of EPRs to be configured depends on the traffic volume, but only one EPR can be configured in the BSC6900. You can also choose not to configure the EPR.
TCRThe number of TCRs to be configured depends on the traffic volume and the configuration modes of subracks. Up to two TCRs can be configured in the BSC6900. You can also choose not to configure a TCR.
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 9
Cabinet
Components of the CabinetComponents of the Cabinet
(1) Air Inlet(2) Independent fan subrack(3) Subrack(4) Air defence subrack(5) Filler panel(6) Power distribution box(7) Cable rack(8) Rear cable through
NOTE: The subracks are numbered from bottom to top, and the MPS is numbered 0.
MPR/EPR/TCR
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 10
Cabinet
Technical Specifications of the CabinetTechnical Specifications of the Cabinet
Item Specification
Dimensions 2,200 mm (height) x 600 mm (width) x 800 mm (depth)
Height of the available space 46 U (1 U = 44.45 mm = 1.75 inches)
Weight • Empty cabinet ≤ 100 kg • Cabinet in full configuration ≤ 320 kg
Rated input voltage -48 V
Input voltage range -40 V to -57 V
Electromagnetic Compatibility (EMC)
• Meets the requirements in ETSI EN300 386 • Meets the requirements in Council directive 89/336/EEC
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 11
Chapter 1 Physical StructureChapter 1 Physical Structure
Chapter 2 CabinetChapter 2 Cabinet
Chapter 3 Cable ConnectionsChapter 3 Cable Connections
Chapter 4 Components of the CabinetChapter 4 Components of the Cabinet
Chapter 5 SubracksChapter 5 Subracks
Chapter 6 BoardsChapter 6 Boards
Chapter 7 CablesChapter 7 Cables
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 12
Cable Connections
Connections of Power Cables and PGND Cables in the CabinetConnections of Power Cables and PGND Cables in the Cabinet
Connections of Power and PGND Cables
SN Description
5, 6, 11, 12 Power cables for the bottom subrack
3, 4, 9, 10 Power cables for the middle subrack
1, 2, 7, 8 Power cables for the top subrack
13 PGND cable connecting the power distribution box and the mounting bar
14, 15, 16, 17, 18, 19 PGND cables connecting the subracks and the mounting bar
24, 25, 26 Inter-cabinet PGND cables
27, 28, 29, 30 Power cables for the independent fan subrack
31 PGND cable connecting the independent fan subrack and the mounting bar
50-57 PGND cables for cabinet doors and side panels
For clearer view
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 13
Cable Connections
Connections of Signal Cables for the MPRConnections of Signal Cables for the MPR
For clearer view
SN Description Connector Type1/Connection Position1
Connector Type2/Connection Position2
Remarks
1 75-ohm coaxial cable or 120-ohm twisted pair cable connecting the GCUa board to the BITS clock
SMB male connector/CLKIN1 port on the GCUa board in slot 13 of the MPS
Connector of the BITS clock/BITS clock port
Figure 1 shows the clock cables connected to the CLKIN1 and CLKIN0 ports. In practice, only one port is used to connect to the BITS clock.
2 75-ohm coaxial cable or 120-ohm twisted pair cable connecting the GCUa board to the BITS clock
SMB male connector/CLKIN0 port on the GCUa board in slot 13 of the MPS
Connector of the BITS clock/BITS clock port
3 75-ohm coaxial cable or 120-ohm twisted pair cable connecting the GCUa board to the BITS clock
SMB male connector/CLKIN1 port on the GCUa board in slot 12 of the MPS
Connector of the BITS clock/BITS clock port
4 75-ohm coaxial cable or 120-ohm twisted pair cable connecting the GCUa board to the BITS clock
SMB male connector/CLKIN0 port on the GCUa board in slot 12 of the MPS
Connector of the BITS clock/BITS clock port
Connections of Signal Cables for the MPR
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 14
Cable Connections
Connections of Signal Cables for the EPRConnections of Signal Cables for the EPR
For clearer view
SN Description Connector Type1/Connection Position1
Connector Type2/Connection Position2
1 Ethernet cable connecting SCUa boards of different subracks
RJ45/The 10/100/1000BASE-T port on the SCUa board in slot 6 of the EPS
RJ45/The 10/100/1000BASE-T port on the SCUa board in slot 6 of the MPS
2 Ethernet cable connecting SCUa boards of different subracks
RJ45/The 10/100/1000BASE-T port on the SCUa board in slot 6 of the EPS
RJ45/The 10/100/1000BASE-T port on the SCUa board in slot 6 of the MPS
3 Ethernet cable connecting SCUa boards of different subracks
RJ45/The 10/100/1000BASE-T port on the SCUa board in slot 7 of the EPS
RJ45/The 10/100/1000BASE-T port on the SCUa board in slot 7 of the MPS
4 Ethernet cable connecting SCUa boards of different subracks
RJ45/The 10/100/1000BASE-T port on the SCUa board in slot 6 of the EPS
RJ45/The 10/100/1000BASE-T port on the SCUa board in slot 6 of the MPS
Connections of Signal Cables for the EPR
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 15
Cable Connections
Connections of Signal Cables for the TCRConnections of Signal Cables for the TCR
For clearer view
SN Description Connector Type1/ Connection Position1
Connector Type2/ Connection Position2
1 Monitoring signal cable for the power distribution box
DB15/Port connecting the power distribution box to the independent fan subrack
DB9/MONITOR 1 port on the independent fan subrack
2 Ethernet cable connecting SCUa boards of different subracks
RJ45/The 10/100/1000BASE-T port on the SCUa board in slot 6 of the main TCS
RJ45/The 10/100/1000BASE-T port on the SCUa board in slot 6 of the TCS
3 Ethernet cable connecting SCUa boards of different subracks
RJ45/The 10/100/1000BASE-T port on the SCUa board in slot 6 of the main TCS
RJ45/The 10/100/1000BASE-T port on the SCUa board in slot 7 of the TCS
4 Ethernet cable connecting SCUa boards of different subracks
RJ45/The 10/100/1000BASE-T port on the SCUa board in slot 6 of the main TCS
RJ45/The 10/100/1000BASE-T port on the SCUa board in slot 6 of the TCS
Connections of Signal Cables for the TCR
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 16
Chapter 1 Physical StructureChapter 1 Physical Structure
Chapter 2 CabinetChapter 2 Cabinet
Chapter 3 Cable ConnectionsChapter 3 Cable Connections
Chapter 4 Components of the CabinetChapter 4 Components of the Cabinet
Chapter 5 SubracksChapter 5 Subracks
Chapter 6 BoardsChapter 6 Boards
Chapter 7 CablesChapter 7 Cables
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 17
Components of the Cabinet
Appearance (Front Panel) of the High-Power Distribution BoxAppearance (Front Panel) of the High-Power Distribution Box
(1) Panel of the PAMU board (2) RUN LED (3) ALM LED
(4) Mute switch (5) Power switches (6) Labels for power switches
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 18
Components of the Cabinet
Appearance (Front Panel) of the High-Power Distribution BoxAppearance (Front Panel) of the High-Power Distribution Box
The mute switch is set to determine whether an audible alarm is generated.
• If you set the mute switch to I, the power distribution box generates an audible alarm when it is faulty. • If you set the mute switch to O, the power distribution box does not generate any audible alarm when it is faulty.
LED Color Status Description
RUN Green ON for 1s and OFF for 1s
The PAMU board is functional and communicates with the SCUa board properly.
ON for 0.25s and OFF for 0.25s
The PAMU board is not working or it does not communicate with the SCUa board properly.
OFF There is no power supply to the PAMU board or the power distribution box does not work properly.
ALM Red OFF There is no alarm related to the power distribution box.
ON The power distribution box is faulty. During the self-check of the PAMU board, however, the ALM LED is also ON. This indicates that the ALM LED is functional.
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 19
Components of the Cabinet
Appearance (Rear Panel) of the High-Power Distribution BoxAppearance (Rear Panel) of the High-Power Distribution Box
(1) Power input terminal block (2) Power output terminal block
(3) Port used to connect the power distribution box to a subrack
(4) 2-hole grounding screw (5) J1 port (6) J2 port (port used to connect the power distribution box to a EMU)
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 20
Components of the Cabinet
Technical Specifications of the High-Power Distribution BoxTechnical Specifications of the High-Power Distribution BoxItem Sub-item Specification
Input Rated input voltage -48 V DC or -60 V DC
Input voltage range -40 V DC to -72 V DC
Input mode Two groups of power inputs: A and B. Group A consists of the power inputs A1+A2 and A3. Group B consists of the power inputs B1+B2 and B3. Each group has one or two -48 V DC or -60 V DC power inputs.
Max. input current The maximum rated input current of each route is 100 A.
Output Rated output voltage -48 V DC or -60 V DC
Output voltage range -40 V DC to -72 V DC
Output mode and current Two groups of power outputs: A and B. Each group has one to four -48 V DC or -60 V DC power outputs. The maximum rated output current of each output is 50 A and that of each group is 100 A.Each output is controlled by MCBs: A7 to A10 and B7 to B10. These MCBs provide the power surge protection function.
Output protection specifications The power surge protection point is 70 A. You need to manually switch on the corresponding MCB after the power surge protection.
Rated output power 9,600 W (Two groups of power outputs: A and B. Each group has two -48 V DC power outputs.)
NOTE: For group A, power inputs A1+A2 correspond to power outputs A1 to A8, and power input A3 corresponds to power outputs A9 and A10. Similarly, for group B, power inputs B1+B2 correspond to power outputs B1 to B8, and power input B3 corresponds to power outputs B9 and B10.
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 21
Components of the Cabinet
Air Defence SubrackAir Defence Subrack
The air defence subrack is installed between two subracks. It is used to form a straight-through air channel. The air
defence subrack is 1 U in height.
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 22
Components of the Cabinet
Rear Cable ThroughRear Cable Through
The rear cable trough is used for routing and binding of the cables of rear boards. Each rear cable trough has three
fiber management trays installed at the bottom to coil the optical cables.
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 23
Components of the Cabinet
Cabling FrameCabling Frame
The cabling frame provides space for the routing of the Ethernet cables for the LAN switch.
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 24
Components of the Cabinet
Lan SwitchLan Switch
(1) POWER LED (2) Mode status LED (A/L LED)
(3) Mode status LED (D/S LED)
(4) Mode switch button (MODE button)
(5) 10M/100M adaptive full-duplex BASE-TX Ethernet ports
(6) Configuration port (CONSOLE port)
(1) DC power socket (2) Grounding post for the PGND
cable
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 25
Components of the Cabinet
Appearance (Front) of the Independent Fan SubrackAppearance (Front) of the Independent Fan Subrack
(1) PFCB or PFCU board (2) Fans (3) Handle of the independent fan subrack
(4) Screw (5) LED on the fan box
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 26
Components of the Cabinet
Appearance (Rear) of the Independent Fan SubrackAppearance (Rear) of the Independent Fan Subrack
(1) Monitor 1 Port, used to connect to the power distribution box
(2) Power input port (3) Monitor 2 Port (Reserved)
(4) Monitor 0 Port, used to connect to subracks
(5) Monitor 3 Port (Reserved)
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 27
Chapter 1 Physical StructureChapter 1 Physical Structure
Chapter 2 CabinetChapter 2 Cabinet
Chapter 3 Cable ConnectionsChapter 3 Cable Connections
Chapter 4 Components of the CabinetChapter 4 Components of the Cabinet
Chapter 5 SubracksChapter 5 Subracks
Chapter 6 BoardsChapter 6 Boards
Chapter 7 CablesChapter 7 Cables
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 28
Classifications of SubracksClassifications of Subracks
Subracks
Based on functions, subracks are classified into the main processing subrack (MPS), extended processing subrack (EPS), and transcoder subrack (TCS).
MPSAs the main processing subrack, the MPS is configured in the MPR. Only one MPS is configured in the BSC6900. The MPS processes the basic services of the BSC6900, performs operation and maintenance, and provides clock signals for the system.
EPSAs the extended processing subrack, the EPS is configured in the MPR or EPR. It processes the basic services of the BSC6900.
TCSAs the transcoder subrack, the TCS is configured in the MPR, EPR, or TCR in BM/TC separated configuration mode. It performs transcoding, rate adaptation, and sub-multiplexing.
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 29
Components of SubracksComponents of Subracks
Subracks
(1) Fan box (2) Mounting ear (3) Guide rail
(4) Front cable trough (5) Boards (6) Grounding screw
(7) DC power input port (8) Port for the monitoring signal cable of the power distribution box
(9) Cover plate of the DIP switch
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 30
Slots in the SubrackSlots in the Subrack
Subracks
The backplane is positioned in the center of the subrack, and the boards are installed on the front and rear sides of the backplane.
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 31
Dip Switch on the SubrackDip Switch on the Subrack
Subracks
Bit Description
1-5 Bits 1 to 5 are used for setting the subrack number. Bit 1 is the least significant bit. If the bit is set to ON, it indicates 0. If the bit is set to OFF, it indicates 1.
6 Odd parity check bit
7 Reserved, undefined, generally set to ON
8 (the most significant bit)
Reserved
Principle of the DIP Switch SettingAs the DIP switch uses odd parity check, the number of 1s in the eight bits must be an odd number. The method for setting the bits is as follows: 1. Set bit 1 to bit 5 as required.2. Set bit 7 to ON.3. Check the number of 1s in the seven bits of the DIP switch. Note that the setting of bit 8 remains unchanged.
• If the number of 1s is even, set bit 6 to OFF.• If the number of 1s is odd, set bit 6 to ON.
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 32
Configuration of the MPSConfiguration of the MPS
Subracks
MPS in full configuration in BM/TC separated configuration mode
The INT board (interface board) can be the PEUa board, EIUa board, OIUa board, FG2a/FG2c board, POUc board, or GOUa/GOUc board
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 33
Configuration of the MPSConfiguration of the MPS
Subracks
MPS in full configuration in BM/TC combined configuration mode
The INT board (interface board) can be the PEUa board, EIUa board, OIUa board, FG2a/FG2c board, POUc board, or GOUa/GOUc board
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 34
Configuration of the MPSConfiguration of the MPS
Subracks
MPS in full configuration in A over IP configuration mode
The INT board (interface board) can be the PEUa board, EIUa board, OIUa board, FG2a/FG2c board, POUc board, or GOUa/GOUc board
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 35
Configuration of the EPSConfiguration of the EPS
Subracks
EPS in full configuration in BM/TC separated configuration mode
The INT board (interface board) can be the PEUa board, EIUa board, OIUa board, FG2a/FG2c board, POUc board, or GOUa/GOUc board
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 36
Configuration of the EPSConfiguration of the EPS
Subracks
EPS in full configuration in BM/TC combined configuration mode
The INT board (interface board) can be the PEUa board, EIUa board, OIUa board, FG2a/FG2c board, POUc board, or GOUa/GOUc board
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 37
Configuration of the EPSConfiguration of the EPS
Subracks
EPS in full configuration in A over IPconfiguration mode
The INT board (interface board) can be the PEUa board, EIUa board, OIUa board, FG2a/FG2c board, POUc board, or GOUa/GOUc board
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 38
Configuration of the TCSConfiguration of the TCS
Subracks
TCS in full configuration when E1/T1 transmission is used on the A interface
By default, the TCS must be configured with the SCUa board and TNUa board. The DPUa/DPUc/DPUf board and EIUa/OIUa board are optional boards
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 39
Configuration of the TCSConfiguration of the TCS
Subracks
TCS in full configuration when STM-1 transmission is used on the A interface
By default, the TCS must be configured with the SCUa board and TNUa board. The DPUa/DPUc/DPUf board and EIUa/OIUa board are optional boards
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 40
Technical Specifications of the SubrackTechnical Specifications of the Subrack
Subracks
Item Specification
Dimensions 530.6 mm (height) x 436 mm (width) x 480 mm (depth)
Available space height 12 U (1 U = 44.45 mm = 1.75 inches)
Weight Empty subrack: 25 kg; subrack configured with boards: ≤ 57 kg
Power consumption in full configuration
•When the subrack is used to house the GSM service boards: MPS: ≤ 1,200 W •EPS: ≤ 1,200 W •TCS: ≤ 1,000 W•When the subrack is used to house the UMTS service boards: MPS: ≤ 1,560 W •EPS: ≤ 1,540 W
The technical specifications of the subrack refer to the dimensions of the subrack, available space height, weight, and power consumption in full configuration.
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 41
Chapter 1 Physical StructureChapter 1 Physical Structure
Chapter 2 CabinetChapter 2 Cabinet
Chapter 3 Cable ConnectionsChapter 3 Cable Connections
Chapter 4 Components of the CabinetChapter 4 Components of the Cabinet
Chapter 5 SubracksChapter 5 Subracks
Chapter 6 BoardsChapter 6 Boards
Chapter 7 CablesChapter 7 Cables
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 42
Boards
DPU Boards DPU Boards Functions Functions
DPU Boards
Encodes and Decodes Voice Services
Provides Data service rate adaptation
Provides Tandem Free Operation (TFO) function
Provides the Voice enhancement function
Detects voice faults automatically
Provides the speech format conversion and data forwarding functions(BM/TC Combined, A over IP/HDLC, Abis over IP/HDLC)
Processes the PS services on up to 1,024 simultaneously active PDCHs where signals are coded in MCS9
Processes packet links
Detects packet faults automatically
DPUa DPUc DPUd DPUf
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 43
Boards
DPU Boards DPU Boards Panel PanelLED Color Status Description
RUN Green ON for 1s and OFF for 1s
The board is functional.
ON for 0.125s and OFF for 0.125s
The board is in loading state.
ON There is power supply, but the board is faulty.
OFF There is no power supply, or the board is faulty.
ALM Red OFF There is no alarm.
ON or blinking There is a fault alarm.
ACT Green ON The board is in active mode.
OFF The board is in standby mode.
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 44
Boards
DPU Boards DPU Boards Technical Specifications Technical SpecificationsItem DPUa DPUc DPUd DPUf
Dimensions 366.7 mm × 220 mm 366.7 mm × 220 mm 366.7 mm × 220 mm 366.7 mm × 220 mm
Power supply Two -48 V DC working in active/standby mode. The backplane of the subrack is responsible for the power supply.
Two -48 V DC working in active/standby mode. The backplane of the subrack is responsible for the power supply.
Two inputs of -48 V DC in active/standby mode. The backplane of the subrack is responsible for the power supply.
Two -48 V DC working in active/standby mode. The backplane of the subrack is responsible for the power supply.
Power consumption 60 W 49.40 W 49.40 W 80 W
Weight 1.26 kg 1.26 kg 1.26 kg 1.20 kg
Operating temperature (long-term)
0°Cto 45°C 0°Cto 45°C 0°Cto 45°C 0°Cto 45°C
Operating temperature (short-term)
-5°Cto +55°C -5°Cto +55°C -5°Cto +55°C -5°Cto +55°C
Relative humidity (long-term) 5% to 85% 5% to 85% 5% to 85% 5% to 85%
Relative humidity (short-term) 5% to 95% 5% to 95% 5% to 95% 5% to 95%
Processing capability Supporting 960 TCH/Fs; supporting 3,740 IWF flow numbers
Processing the PS services on up to 1,024 simultaneously active PDCHs where signals are coded in MCS9
Supporting 1,920 TCHFs Supporting 7,680 IWF flow numbers in the case of all-IP networking; Supporting 3,840 IWF flow numbers in the case of Abis over TDM or Ater over TDM
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 45
Boards
EIUa BoardEIUa Board
The EIUa board provides E1/T1 transmission for the BSC6900.The EIUa board performs the following functions:
• Provides four E1/T1 electrical ports for TDM transmission• Transmits, receives, encodes, and decodes 32 E1s/T1s. The E1 transmission rate is 2.048 Mbit/s; the T1 transmission rate is 1.544 Mbit/s • Processes signals according to the LAPD protocol • Processes signals according to the SS7 MTP2 protocol • Provides the Tributary Protect Switch (TPS) function between the active and standby EIUa boards • Provides the OM links when the TCS is configured on the MSC side • Supports the A, Abis, Ater, and Pb interfaces
LED Color Status Description
RUN Green ON for 1s and OFF for 1s The board is functional.
ON for 0.125s and OFF for 0.125s
The board is in loading state.
ON There is power supply, but the board is faulty.
OFF There is no power supply, or the board is faulty.
ALM Red OFF There is no alarm.
ON or blinking There is a fault alarm.
ACT Green ON The board is in active mode.
OFF The board is in standby mode.Setting for 75-ohm Coaxial Cable ONSetting for 120-ohm Twisted Pair Cable OFF
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 46
Boards
FG2a BoardFG2a BoardAs an interface board, the FG2a board provides IP over Ethernet.The FG2a board performs the following functions:
• Provides eight channels over FE ports or two channels over GE ports • Provides the routing-based backup and load sharing • Provides the link aggregation function at the MAC layer • Supports the A, Abis, Gb, Iu, Iur, and Iub interfaces
Port Function Connector Type
FE(1) to FE(3) 10M/100M Ethernet ports, used to transmit 10/100M signals RJ45
FE/GE(0) 10M/100M/1000M Ethernet ports, used to transmit 10/100/1000M signals RJ45
2M0 and 2M1 Port for 2 MHz clock signal outputs SMB male connector
LED Color Status Description
RUN Green ON for 1s and OFF for 1s The board is functional.
ON for 0.125s and OFF for 0.125s The board is in loading state.
ON There is power supply, but the board is faulty.
OFF There is no power supply, or the board is faulty.
ALM Red OFF There is no alarm.
ON or blinking There is a fault alarm.
ACT Green ON The board is in active mode.
OFF The board is in standby mode.
LINK (at the Ethernet port) Green ON The link is well connected.
OFF The link is disconnected.
ACT (at the Ethernet port) Green OFF There is no data transmission over the Ethernet port.
Blinking There is data transmission over the Ethernet port.
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 47
Boards
FG2c BoardFG2c BoardAs an interface board, the FG2c board supports IP over Ethernet transmission.The FG2c board performs the following functions:
• Provides twelve channels over FE ports or eight channels over FE ports and four channels over GE ports • Provides the link aggregation function at the MAC layer • Provides the routing-based backup and load sharing • Supports the transmission of data over all its Ethernet ports on the basis of the synchronized clock signals • Supports the Abis, A, Gb, Iu, Iur, and Iub interfaces
LED Color Status Description
RUN Green ON for 1s and OFF for 1s The board is functional.
ON for 0.125s and OFF for 0.125s The board is in loading state.
ON There is power supply, but the board is faulty.
OFF There is no power supply, or the board is faulty.
ALM Red OFF There is no alarm.
ON or blinking There is a fault alarm.
ACT Green ON The board is in active mode.
OFF The board is in standby mode.
LINK (at the Ethernet port) Green ON The link is well connected.
OFF The link is disconnected.
ACT (at the Ethernet port) Orange OFF There is no data transmission over the Ethernet port.
Blinking There is data transmission over the Ethernet port.
Port Function Connector Type
100BASE-T 100M Ethernet ports, used to transmit 100M signals RJ45
100/1000BASE-T 100M/1000M Ethernet ports, used to transmit 100/1000M signals RJ45
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 48
Boards
GCUa/GCGa BoardGCUa/GCGa BoardThe GCUa/GCGa board performs the clock function.The GCUa/GCGa board performs the following functions:
• Extracts timing signals from the external synchronization timing port and from the synchronization line signals, processes the timing signals, and provides the timing signals and the reference clock for the entire system • Performs the fast pull-in and holdover functions on the system clock •Generates RFN signals for the system •Supports active/standby switchover. The standby GCUa/GCGa board traces the clock phase of the active GCUa/GCGa board. This ensures the smooth output of the clock phase in the case of active/standby switchover. •Receives and processes the clock signals and the positioning information from the GPS card
LED Color Status Description
RUN Green ON for 1s and OFF for 1s The board is functional.
ON for 0.125s and OFF for 0.125s
The board is in loading state.
ON There is power supply, but the board is faulty.
OFF There is no power supply, or the board is faulty.
ALM Red OFF There is no alarm.
ON or blinking There is a fault alarm.
ACT Green ON The board is in active mode.
OFF The board is in standby mode.
Port Function Connector Type
ANT Port for the GPS antenna. This port on the GCGa board is used to receive the timing signals and positioning information from the GPS satellite. This port is not used on the GCUa board.
SMA male connector
CLKOUT0 to CLKOUT9
Ports for providing synchronization clock signals. The ten ports are used to provide 8 kHz clock signals and 1PPS clock signals.
RJ45
COM0 Reserved RJ45
COM1 Port for RS422-level 8 kHz clock signals
RJ45
TESTOUT Output port for clock signals. The clock signals are used for testing.
SMB male connector
TESTIN Input port for testing external clock signals
SMB male connector
CLKIN0 and CLKIN1
Input port for BITS clock signals and line clock signals
SMB male connector
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 49
Boards
GOUa/GOUc BoardGOUa/GOUc BoardAs an optical interface board, the GOUa board supports IP over Ethernet.The GOUa board performs the following functions:
• Provides two(GOUa)/four(GOUc) channels over GE optical ports, which are used for IP transmission • Provides the routing-based backup and load sharing • Supports the A(GOUa/GOUc), Abis (GOUa/GOUc), Gb (GOUc) interfaces
LED Color Status Description
RUN Green ON for 1s and OFF for 1s
The board is functional.
ON for 0.125s and OFF for 0.125s
The board is in loading state.
ON There is power supply, but the board is faulty.
OFF There is no power supply, or the board is faulty.
ALM Red OFF There is no alarm.
ON or blinking There is a fault alarm.
ACT Green ON The board is in active mode.
OFF The board is in standby mode.
LINK (optical port LED)
Green ON The link is well connected.
OFF The link is disconnected.
ACT (optical port LED)
Green OFF There is no data transmission over the Ethernet port.
Blinking There is data transmission over the Ethernet port.
Port Function Connector Type
RX Optical port, used to transmit and receive optical signals. TX refers to the transmitting optical port, and RX refers to the receiving optical port.
LC/PC
TX
2M0 and 2M1
Port for 2 MHz clock signal outputs SMB male connector
Item GOUa Specs GOUc Specs
Abis TRX 384 2,048
A CIC(64K) 6,144 23,040
Gb Maximum payload throughput (physical layer)
N/A 1,024 Mbit/s
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 50
Boards
OMUa/OMUb BoardOMUa/OMUb BoardThe OMUa/OMUb board works as a bridge for the communication between the Local Maintenance Terminal (LMT) and the other boards in the BSC6900.The OMUa board performs the following functions:
• Performs the configuration management, performance management, fault management, security management, and loading management functions for the system •Provides the LMT or M2000 users with the operation and maintenance port of the BSC6900 system, to control the communication between the LMT or M2000 and the SCUa board of the BSC6900
(1) Captive screw
(2) Ejector lever
(3) Self-locking latch
(4) RUN LED
(5) ALM LED
(6) ACT LED
(7) RESET Button
(8) SHUTDOWN Button
(9) USB port
(10) ETH0 Ethernet port
(11) ETH1 Ethernet port
(12) ETH2 Ethernet port
(13) COM port
(14) VGA port
(15) HD LEDs
(16) OFFLINE LED
(17) Hard Disks
(18) Screws for fixing the HD
LED Color Status Description
RUN Green
ON for 1s and OFF for 1s The board is functional.
ON for 0.125s and OFF for 0.125s
The board is being started.
ON There is power supply, but the board is faulty.
OFF There is no power supply, or the board is faulty.
ALM Red OFF There is no alarm.
ON or blinking There is a fault alarm.
ACT Green
ON The board is in active mode.
OFF The board is in standby mode, or the board is disconnected.
OFFLINE
Blue ON The board can be removed.
OFF The board cannot be removed.
ON for 0.125s and OFF for 0.125s
The board is being switched over to the other working mode.
HD Green
OFF There is no read or write operation on the hard disk.
Blinking The hard disk is being read or written.
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 51
Boards
PEUa BoardPEUa BoardAs an interface board, the PEUa board supports E1/T1 transmission.The PEUa board performs the following functions:
•Provides 32 channels of IP over PPP/MLPPP over E1/T1•Provides 128 PPP links or 32 MLPPP groups, each MLPPP group containing 8 MLPPP links•Provides the Tributary Protect Switch (TPS) function between the active and standby PEUa boards•Transmits, receives, encodes, and decodes 32 channels of E1s/T1s. The E1 transmission rate is 2.048 Mbit/s; the T1 transmission rate is 1.544 Mbit/s.•Supports the Abis, Gb, and Iub interfaces
LED Color Status Description
RUN Green ON for 1s and OFF for 1s
The board is functional.
ON for 0.125s and OFF for 0.125s
The board is in loading state.
ON There is power supply, but the board is faulty.
OFF There is no power supply, or the board is faulty.
ALM Red OFF There is no alarm.
ON or blinking There is a fault alarm.
ACT Green ON The board is in active mode.
OFF The board is in standby mode.
Port Function Connector Type
E1/T1 (0-7) E1/T1 port, used to transmit and receive E1/T1 signals on channels 0-7
DB44
E1/T1 (8-15) E1/T1 port, used to transmit and receive E1/T1 signals on channels 8-15
DB44
E1/T1 (16-23) E1/T1 port, used to transmit and receive E1/T1 signals on channels 16-23
DB44
E1/T1 (24-31) E1/T1 port, used to transmit and receive E1/T1 signals on channels 24-31
DB44
2M0 and 2M1 Port for 2 MHz clock signal outputs SMB male connector
Item Specifications
Abis TRX 384
Gb Maximum payload throughput (physical layer) 64 Mbit/s
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 52
Boards
SCUa BoardSCUa BoardThe SCUa board provides the maintenance management and GE switching platform for the subrack in which it is located. Thus, the BSC6900 internal MAC switching is implemented and the internal switching in turn enables complete connection between modules of the BSC6900.
The SCUa board performs the following functions:• Provides the maintenance management function • Provides configuration and maintenance of a subrack or of the entire BSC6900 • Monitors the power supply, fans, and environment of the cabinet • Supports the port trunking function • Supports the active/standby switchover • Enables inter-subrack connections • Provides a total switching capacity of 60 Gbit/s • Distributes clock signals and RFN signals for the BSC6900
LED Color Status Description
RUN Green ON for 1s and OFF for 1s The board is functional.
ON for 0.125s and OFF for 0.125s
The board is in loading state.
ON There is power supply, but the board is faulty.
OFF There is no power supply, or the board is faulty.
ALM Red OFF There is no alarm.
ON or blinking There is a fault alarm.
ACT Green ON The board is in active mode.
OFF The board is in standby mode.
LINK (at the Ethernet port)
Green ON The link is well connected.
OFF The link is disconnected.
ACT (at the Ethernet port)
Green OFF There is no data transmission over the Ethernet port.
Blinking There is data transmission over the Ethernet port.
Port Function Connector Type
10/100/1000BASE-T0 to 10/100/1000BASE-T9
10M/100M/1000M Ethernet ports, used for the inter-subrack connection.
RJ45
10/100/1000BASE-T10 to 10/100/1000BASE-T11
10M/100M/1000M Ethernet ports, the two ports are unused in the BSC6900.
RJ45
COM Serial port for commissioning.
RJ45
CLKIN Port for reference clock signal inputs, used to receive the 8 kHz and the 1 PPS clock signals from the GCUa/GCGa board.
RJ45
TESTOUT Port for clock signal outputs. The clock signals are used for testing.
SMB male connector
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 53
Boards
TNUa BoardTNUa BoardThe TNUa board provides the TDM switching and serves as the switching center for the CS services of the entire system.
The TNUa board performs the following functions:• Provides 128K x 128K time slots TDM switching • Allocates the TDM network resources
LED Color Status Description
RUN Green ON for 1s and OFF for 1s The board is functional.
ON for 0.125s and OFF for 0.125s
The board is in loading state.
ON There is power supply, but the board is faulty.
OFF There is no power supply, or the board is faulty.
ALM Red OFF There is no alarm.
ON or blinking There is a fault alarm.
ACT Green ON The board is in active mode.
OFF The board is in standby mode.
Port Function Connector Type
TDM0 to TDM5 TDM high-speed serial ports, used to connect the TNUa boards in different subracks DB14
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 54
Boards
XPUa/XPUb BoardXPUa/XPUb BoardMain Control XPUa/XPUb/XPUb BoardThe main control XPUa/XPUb board has four /eightlogical subsystems.
Subsystem 0 of the main control XPUa/XPUb board is the Main Processing Unit (MPU). It is used to manage the user plane resources, control plane resources, and transmission resources of the system. The functions are described as follows:
• Managing the user plane resources; managing the load sharing of the user plane resources between subracks• Maintaining the load of the control plane within the subrack; exchanging the load information on the control planes between subracks• Providing functions such as the logical main control function of the BSC6900, the IMSI-RNTI maintenance and query, and the IMSI-CNid maintenance and query• Forwarding the RRC connection request message to implement the sharing of user plane resources and sharing of control plane resources in the BSC6900
Subsystems 1 to 3/1 to 7 of the main control XPUa/XPUb board belong to the CPU for Service (CPUS), which is used to process the services on the control plane. The functions are described as follows:
• Processing upper-layer signaling over the A, Um, Abis, and Ater interfaces• Processing transport layer signaling• Allocating and managing the various resources that are necessary for service setup, and establishing signaling and service connections• Processing RFN signaling
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 55
Boards
XPUa/XPUb BoardXPUa/XPUb BoardNon-Main Control XPUa/XPUb BoardThe non-main control XPUa/XPUb board has four /eight logical subsystems.
The four/eight subsystems of the non-main control XPUa/XPUb board belong to the CPUS, which is used to process the services on the control plane. The functions are described as follows:
• Processing upper-layer signaling over the A, Um, Abis, and Ater interfaces • Processing transport layer signaling • Allocating and managing the various resources that are necessary for service setup, and establishing signaling and service connections • Processing RFN signaling
Port Function Connector Type
10/100/1000BASE-T0 to 10/100/1000BASE-T3 10M/100M/1000M Ethernet ports RJ45
Processing capability of the main control XPUa board
Supporting 270 TRXs, 270 cells, 270 BTSs, and 492,000 Busy Hour Call Attempts (BHCAs)
Processing capability of the non-main control XPUa board
Supporting 360 TRXs, 360 cells, 360 BTSs, and 656,000 BHCAs
Processing capability of the main control XPUb board
Supporting 640 TRXs, 640 cells, 640 BTSs, and 1,148,000 BHCAs
Processing capability of the non-main control XPUb board
Supporting 640 TRXs, 640 cells, 640 BTSs, and 1,312,000 BHCAs
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 56
Chapter 1 Physical StructureChapter 1 Physical Structure
Chapter 2 CabinetChapter 2 Cabinet
Chapter 3 Cable ConnectionsChapter 3 Cable Connections
Chapter 4 Components of the CabinetChapter 4 Components of the Cabinet
Chapter 5 SubracksChapter 5 Subracks
Chapter 6 BoardsChapter 6 Boards
Chapter 7 CablesChapter 7 Cables
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 57
Cables
Power CablesPower CablesExternal power cables
Name Color Cross-Sectional Area (mm2)
Connector Type 1/Installation Position 1
Connector Type 2/Installation Position 2
Quantity
External -48 V power cable
Blue 25/35 2-hole JG terminal/-48 V DC input port on the power distribution box
OT terminal/-48 V DC output port on the PDF
Four per cabinet
External RTN power cable
Black 25/35 2-hole JG terminal/-48 V DC input port on the power distribution box
OT terminal/-48 V DC output port on the PDF
Four per cabinet
(1) OT terminal (2) 2-hole JG terminal
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 58
Cables
Power CablesPower CablesInternal power cables
Name Color Cross-Sectional Area (mm2)
Connector Type 1/Installation Position 1
Connector Type 2/Installation Position 2
Quantity
External -48 V power cable
Blue 10 OT terminal/-48 V DC input port on the power distribution box
OT terminal/-48 V DC output port on the subrack
Two per subrack
External RTN power cable
Black 10 OT terminal/-48 V DC input port on the power distribution box
OT terminal/-48 V DC output port on the subrack
Two per subrack
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 59
Cables
Power CablesPower CablesInternal power cable for the independent fan subrack
Name Color Cross-Sectional Area (mm2)
Connector Type 1/Installation Position 1
Connector Type 2/Installation Position 2
Quantity
External -48 V power cable
Blue 2 OT terminal/-48 V DC input port on the power distribution box
OT terminal/-48 V DC output port on the subrack
Two per independent fan subrack
External RTN power cable
Black 2 OT terminal/-48 V DC input port on the power distribution box
OT terminal/-48 V DC output port on the subrack
Two per independent fan subrack
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 60
Cables
PGND CablesPGND CablesCable Name Color Cross-Sectional
Area (mm2)
Connector Type 1/Installation Position 1
Connector Type 2/Installation Position 2 Quantity
External PGND cable Green and yellow
25/35 OT terminal/Grounding bolt at the top rear of each cabinet
OT terminal/PGND output port on the PDF
One per cabinet
Inter-cabinet PGND cable
Green and yellow
6 OT terminal/PGND busbar of each cabinet
OT terminal/PGND busbar of each cabinet
Three between every two adjacent cabinets
PGND cable for the power distribution box
Green and yellow
6 OT terminal/PGND busbar of each cabinet
OT terminal/Port for PGND cable on the power distribution box
One per power distribution box
PGND cable for the subrack
Green and yellow
6 OT terminal/PGND busbar of each cabinet
OT terminal/Port for the PGND cable on the subrack
Two per subrack
PGND cable for the cabinet door
Green and yellow
6 OT terminal/Grounding bolt on the base
OT terminal/Grounding bolt on the cabinet door
Eight per cabinet
PGND cable for the independent fan subrack
Green and yellow
6 OT terminal/PGND busbar of each cabinet
OT terminal/Grounding point of the independent fan subrack
One per independent fan subrack
PGND cable for the independent fan subrack Other PGND cables
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 61
Cables
Active/Standby 120-ohm Twisted Pair CableActive/Standby 120-ohm Twisted Pair Cable
(1) DB44 connector (2) Metal case of the DB44 connector
(3) Label 1 (identifying a twisted pair cable) (4) Main label (identifying the code, version, and manufacturer of the cable)
(5) Label 2 (identifying a twisted pair cable)
X1 W3 Color X1 W4 Color
Pin of DB44 Connector
Signal Twisted Pair Cable Identifier
Pin of DB44 Connector
Signal Twisted Pair Cable Identifier
38 Ring/R-
R1 Blue 15 Ring/R-
T1 Blue
23 Tip/R+
White 30 Tip/R+
White
37 Ring/R-
R2 Orange
14 Ring/R-
T2 Orange
22 Tip/R+
White 29 Tip/R+
White
36 Ring/R-
R3 Green 13 Ring/R-
T3 Green
21 Tip/R+
White 28 Tip/R+
White
35 Ring/R-
R4 Brown 12 Ring/R-
T4 Brown
20 Tip/R+
White 27 Tip/R+
White
34 Ring/T-
R5 Grey 11 Ring/T-
T5 Grey
19 Tip/T+
White 26 Tip/T+
White
33 Ring/T-
R6 Blue 10 Ring/T-
T6 Blue
18 Tip/T+
Red 25 Tip/T+
Red
32 Ring/T-
R7 Orange
9 Ring/T-
T7 Orange
17 Tip/T+
Red 24 Tip/T+
Red
31 Ring/T-
R8 Green 8 Ring/T-
T8 Green
16 Tip/T+
Red 7 Tip/T+
Red
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 62
Cables
Inter-TNUa CableInter-TNUa Cable
(1) DB14 (2) Label (identifying a pair of twisted pair cables)
(3) Main label (identifying the code, version, and manufacturer of the cable)
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 63
Cables
Line/BITS Clock CableLine/BITS Clock Cable
(1) SMB connector/BNC (2) Label
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 64
Cables
Y-Shaped Clock CableY-Shaped Clock Cable
(1) Label (identifying a pair of twisted pair cables) (2) RJ45 connector
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 65
Cables
Monitoring Signal Cable for the Independent Fan Monitoring Signal Cable for the Independent Fan SubrackSubrack
InstallationThe DB15 connector at one end of the monitoring signal cable
for the independent fan subrack is connected to the MONITOR 0 port on the independent fan subrack. The DB9 connector at the other end of the cable is connected to the Monitor port on the
bottom subrack.
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
Page 66
Cables
Monitoring Signal Cable for the Power Distribution BoxMonitoring Signal Cable for the Power Distribution Box
InstallationThe DB15 connector at one end of the monitoring signal cable for the power distribution box is connected to the corresponding port on the power distribution box. The DB9 connector at the other end of the cable is connected to the MONITOR 1 port on the independent fan subrack.