Download - BREVE PRESENTAZIONE DEL RELATORE
![Page 1: BREVE PRESENTAZIONE DEL RELATORE](https://reader034.vdocuments.mx/reader034/viewer/2022051421/5681641f550346895dd5de57/html5/thumbnails/1.jpg)
BREVE PRESENTAZIONE DEL RELATORE
L’ING. DI MARCO GIAN LUCA SI OCCUPA DI :
1) SICUREZZA SUL LAVORO E QUALITA’ AI SENSI DELLA ISO 9001:2008 PER UN’AZIENDA OPERANTE NEL SETTORE ELETTROSTRUMENTALE E DEI SISTEMI DI ANALISI PER L’INDUSTRIA DI PROCESSO;
2) CONSULENZA TECNICA NEL SETTORE DEL FOTOVOLTAICO PER LA SOCIETA’ COOPERATIVA 9SYSTEM;
3) BREVI MA SIGNIFICATIVE ESPERIENZE NEL SETTORE DIDATTICO PER LA PREPARAZIONE AD ESAMI UNIVERSITARI.
4) CERTIFICAZIONE ENERGETICA DEGLI EDIFICI E PROGETTAZIONE DEGLI INTERVENTI DI RIQUALIFICAZIONE
![Page 2: BREVE PRESENTAZIONE DEL RELATORE](https://reader034.vdocuments.mx/reader034/viewer/2022051421/5681641f550346895dd5de57/html5/thumbnails/2.jpg)
SISTEMI FOTOVOLTAICI PER ILRISPARMIO ENERGETICOIDEE ED APPLICAZIONI PER UN CONSUMO
SOSTENIBILE Ing. Gian Luca Di Marco
Massafra, 20/04/2012
![Page 3: BREVE PRESENTAZIONE DEL RELATORE](https://reader034.vdocuments.mx/reader034/viewer/2022051421/5681641f550346895dd5de57/html5/thumbnails/3.jpg)
EFFETTO FOTOVOLTAICO
La teoria fisica che spiega l’effetto fotoelettrico si può far risalire ad A. Einstein che per questi studi fu insignito del premio Nobel per la fisica nel 1921
![Page 4: BREVE PRESENTAZIONE DEL RELATORE](https://reader034.vdocuments.mx/reader034/viewer/2022051421/5681641f550346895dd5de57/html5/thumbnails/4.jpg)
CELLA FV
La cella FV è un dispositivo
elettronico costituito da una giunzione P-N all’interno della quale
si generano coppie elettrone-lacuna e
quindi corrente elettrica per effetto
della radiazione incidente
Nell’effetto fotoelettrico l’energia cinetica degli elettroni estratti da un metallo è direttamente correlata all’energia della radiazione incidente ed all’energia Eg di estrazione caratteristica del materiale
![Page 5: BREVE PRESENTAZIONE DEL RELATORE](https://reader034.vdocuments.mx/reader034/viewer/2022051421/5681641f550346895dd5de57/html5/thumbnails/5.jpg)
CARATTERISTICA I-VLA CARATTERISTICA I-V DELLA
CELLA FV MOSTRA IL COMPORTAMENTODELLA STESSA IN CONDIZIONI DI BUIO EILLUMINAZIONE: SI NOTA LA CLASSICA
CARATTERISTICA DEL DIODO A GIUNZIONE
iL = corrente fotogenerataRs= resistenza serieRsh= resistenza di shunt
![Page 6: BREVE PRESENTAZIONE DEL RELATORE](https://reader034.vdocuments.mx/reader034/viewer/2022051421/5681641f550346895dd5de57/html5/thumbnails/6.jpg)
Maximum Power Point
Load line
Radiazione incidente
![Page 7: BREVE PRESENTAZIONE DEL RELATORE](https://reader034.vdocuments.mx/reader034/viewer/2022051421/5681641f550346895dd5de57/html5/thumbnails/7.jpg)
CONDIZIONI STANDARD
LE CARATTERISTICHE ELETTRICHE DI UNA CELLA FV VARIANO AL VARIARE DELLA POTENZA INCIDENTE (W/Mq) , DELLA TEMPERATURA DI CELLA E DELL’ AIR MASS (AM). PERTANTO IL COSTRUTTORE DEFINISCE LE PRESTAZIONI DELLA CELLA IN CONDIZIONI STANDARD: Pinc= 1000 W/Mq; TJ= 25°C; AM=1,5
![Page 8: BREVE PRESENTAZIONE DEL RELATORE](https://reader034.vdocuments.mx/reader034/viewer/2022051421/5681641f550346895dd5de57/html5/thumbnails/8.jpg)
TECNOLOGIE
LE TECNOLOGIE PIU’ COMMERCIALIZZATE SONO IL
SILICIO CRISTALLINO (MONO E POLI) ED IL SILICIO
AMORFOIL SILICIO AMORFO HA UN’OTTIMA ADATTABILITA’ ALLE SUPERFICI MA UNA RESA INFERIORE AL CRISTALLINO
![Page 9: BREVE PRESENTAZIONE DEL RELATORE](https://reader034.vdocuments.mx/reader034/viewer/2022051421/5681641f550346895dd5de57/html5/thumbnails/9.jpg)
TECNOLOGIE
STRATIFICAZIONE DEL PANNELLO FV
EVA = ETHYLENE-VINYL- ACETATE
![Page 10: BREVE PRESENTAZIONE DEL RELATORE](https://reader034.vdocuments.mx/reader034/viewer/2022051421/5681641f550346895dd5de57/html5/thumbnails/10.jpg)
TECNOLOGIE
IL SILICIO AMORFO E’ PiU’ SENSIBILE ALLE BASSE LUNGHEZZE
D’ONDA DELLO SPETTRO DI
RADIAZIONE SOLARE
![Page 11: BREVE PRESENTAZIONE DEL RELATORE](https://reader034.vdocuments.mx/reader034/viewer/2022051421/5681641f550346895dd5de57/html5/thumbnails/11.jpg)
NUOVE TECNOLOGIE
FOTOVOLTAICO A CONCENTRAZIONE
TERMOFOTOVOLTAICO
![Page 12: BREVE PRESENTAZIONE DEL RELATORE](https://reader034.vdocuments.mx/reader034/viewer/2022051421/5681641f550346895dd5de57/html5/thumbnails/12.jpg)
DALLA CELLA FV AL MODULO
SERIE DI CELLE INTERCONNESSE FRA LORO
![Page 13: BREVE PRESENTAZIONE DEL RELATORE](https://reader034.vdocuments.mx/reader034/viewer/2022051421/5681641f550346895dd5de57/html5/thumbnails/13.jpg)
HOT SPOT
SE UNA DELLE CELLE DEL MODULO FV SUBISCE OMBREGGIAMENTO VA
IN BASSA CONDUZIONE E IN CONDIZIONI DI BASSO CARICO VIENE SOTTOPOSTA AD UNA
TENSIONE INVERSA PARI ALLA SOMMA DI TUTTE LE TENSIONI A VUOTO DELLE ALTRE CELLE POSTE
IN SERIE A QUEST’ULTIMA.LA CELLA PUO’ SUBIRE
SURRISCALDAMENTO TALE DA PORTARLA A ROTTURA
![Page 14: BREVE PRESENTAZIONE DEL RELATORE](https://reader034.vdocuments.mx/reader034/viewer/2022051421/5681641f550346895dd5de57/html5/thumbnails/14.jpg)
LA CURA DEGLI HOT SPOTS
![Page 15: BREVE PRESENTAZIONE DEL RELATORE](https://reader034.vdocuments.mx/reader034/viewer/2022051421/5681641f550346895dd5de57/html5/thumbnails/15.jpg)
LAYOUT IMPIANTISTICII PANNELLI FOTOVOLTAICI SI
COLLEGANO IN SERIE FORMANDO LE STRINGHE FV E LE STRINGHE SI COLLEGANO IN
PARALLELO FORMANDO IL CAMPO FV: LA CONNESSIONE ALL’INVERTER PUO’ ESSERE DI TIPO CENTRALIZZATO (QUADRI DI PARALLELO IN CONTINUA) O
PER SINGOLA STRINGA (INVERTER DI STRINGA E
QUADRO DI PARALLELO IN ALTERNATA)
SI NOTANO I DIODI DI BY-PASS IN PARALLELO AL SINGOLO PANNELLO ED I DIODI DI BLOCCO ASSOCIATI ALLA SINGOLA STRINGA PER EVITARE LA CIRCOLAZIONE DI CORRENTI INVERSE PROVENIENTI DA ALTRE STRINGHE IN CASO DI MISMATCH
![Page 16: BREVE PRESENTAZIONE DEL RELATORE](https://reader034.vdocuments.mx/reader034/viewer/2022051421/5681641f550346895dd5de57/html5/thumbnails/16.jpg)
LAYOUT IMPIANTISTICI
STAND ALONE
GRID CONNECTED
![Page 17: BREVE PRESENTAZIONE DEL RELATORE](https://reader034.vdocuments.mx/reader034/viewer/2022051421/5681641f550346895dd5de57/html5/thumbnails/17.jpg)
LAYOUT IMPIANTISTICI
TIPOLOGIA IMPIANTISTICA INCENTIVATA DAL CONTO ENERGIA
![Page 18: BREVE PRESENTAZIONE DEL RELATORE](https://reader034.vdocuments.mx/reader034/viewer/2022051421/5681641f550346895dd5de57/html5/thumbnails/18.jpg)
DISPOSITIVO DI INTERFACCIA
CONSENTE LO SGANCIO DALLA RETE IN CASO DI ANOMALE CONDIZIONI DI
FUNZIONAMENTO
![Page 19: BREVE PRESENTAZIONE DEL RELATORE](https://reader034.vdocuments.mx/reader034/viewer/2022051421/5681641f550346895dd5de57/html5/thumbnails/19.jpg)
MPPT
GLI ATTUALI INVERTERS SONO DOTATI DI DISPOSITIVI IN GRADO DI INSEGUIRE IL PUNTO DI MASSIMA POTENZA SE C’E’ UNA REPENTINA
VARIAZIONE DI LUMINOSITA’ (ES. NUVOLE)
![Page 20: BREVE PRESENTAZIONE DEL RELATORE](https://reader034.vdocuments.mx/reader034/viewer/2022051421/5681641f550346895dd5de57/html5/thumbnails/20.jpg)
STRUTTURE DI SOSTEGNO
NO ALL’IMPROVVISAZIONE!!!!
DEVONO ESSERE CERTIFICATE E CONFORMI
ALLE NORME TECNICHE PER LE COSTRUZIONI CON VERIFICA AGLI SLU E SLE
![Page 21: BREVE PRESENTAZIONE DEL RELATORE](https://reader034.vdocuments.mx/reader034/viewer/2022051421/5681641f550346895dd5de57/html5/thumbnails/21.jpg)
DIMENSIONAMENTO DI MASSIMA
I FATTORI DI CORREZIONE SI APPLICANO ALLA POTENZA PRODOTTA DALL’IMPIANTO CHE, SUCCESSIVAMENTE, SARA’ CORRETTA CON I
RENDIMENTI DEL SISTEMA B.O.S.
![Page 22: BREVE PRESENTAZIONE DEL RELATORE](https://reader034.vdocuments.mx/reader034/viewer/2022051421/5681641f550346895dd5de57/html5/thumbnails/22.jpg)
NORMATIVA DI RIFERIMENTO
LA NORMATIVA DI RIFERIMENTO PER LA PROGETTAZIONE DI IMPIANTI FV E’ LA CEI 82-25 E PER LA CONNESSIONE ALLA RETE ELETTRICA SI CONSIDERA LA CEI 0-16 (PER UTENTI ATTIVI E PASSIVI)
![Page 23: BREVE PRESENTAZIONE DEL RELATORE](https://reader034.vdocuments.mx/reader034/viewer/2022051421/5681641f550346895dd5de57/html5/thumbnails/23.jpg)
FORMULE INCENTIVANTI CONTO ENERGIA 2011: D.M. 5 MAGGIO 2011
INCENTIVO DIFFERENZIATO PER FASCE DI POTENZA
INSTALLATA
![Page 24: BREVE PRESENTAZIONE DEL RELATORE](https://reader034.vdocuments.mx/reader034/viewer/2022051421/5681641f550346895dd5de57/html5/thumbnails/24.jpg)
IMPIANTI INCENTIVATIIMPIANTI SOLARI FOTOVOLTAICI TITOLO IIIMPIANTI SOLARI FOTOVOLTAICI
INTEGRATI CON CARATTERISTICHE INNOVATIVE
TITOLO III
IMPIANTI FOTOVOLTAICI A CONCENTRAZIONE TITOLO IV
![Page 25: BREVE PRESENTAZIONE DEL RELATORE](https://reader034.vdocuments.mx/reader034/viewer/2022051421/5681641f550346895dd5de57/html5/thumbnails/25.jpg)
SIMULAZIONEPer un’utile simulazione del conto energia e delle sue implicazioni si visiti la pagina: http://www.ingalessandrocaffarelli.it/download.asp?totale=%204842
![Page 26: BREVE PRESENTAZIONE DEL RELATORE](https://reader034.vdocuments.mx/reader034/viewer/2022051421/5681641f550346895dd5de57/html5/thumbnails/26.jpg)
SMALTIMENTO DEI MODULIIN EUROPA E’ STATO
ISTITUITO NEL 2008 IL CONSORZIO PV-CYCLE CHE
PREDISPONE PROGRAMMI DI RECUPERO E SMALTIMENTO
DI PANNELLI FV OBSOLETI
IN ITALIA E’ STATO INTRODOTTO L’OBBLIGO, A DECORRERE DAL 30/06/12, PER IL PROPRIETARIO DI ADERIRE AD UN CONSORZIO CHE ASSICURI IL RECUPERO DEI MODULI A FINE CICLO. (DM 05 MAGGIO 2011: IV° CONTO ENERGIA)
![Page 27: BREVE PRESENTAZIONE DEL RELATORE](https://reader034.vdocuments.mx/reader034/viewer/2022051421/5681641f550346895dd5de57/html5/thumbnails/27.jpg)
CLASSE ENERGETICAALLA CLASSIFICAZIONE ENERGETICA DEGLI IMMOBILI SI ASSOCIA ANCHE L’UTILIZZO DI FONTI DI ENERGIA RINNOVABILI COME IL FOTOVOLTAICO.
EPgl= EPinv+EPacs
![Page 28: BREVE PRESENTAZIONE DEL RELATORE](https://reader034.vdocuments.mx/reader034/viewer/2022051421/5681641f550346895dd5de57/html5/thumbnails/28.jpg)
CLASSIFICAZIONE ENERGETICA E CONTO ENERGIA
• IL PREMIO PUO’ RAGGIUNGERE IL 30% DELLA TARIFFA BASE ATTUANDO INTERVENTI DI RIQUALIFICAZIONE CHE RIDUCANO DI ALMENO IL 10% L’EPinv E L’EPest
PER MAGGIORI INFORMAZIONI CI SI COLLEGHI ALLA PAGINA DEL GSE: http://www.gse.it/it/Conto%20Energia/Fotovoltaico/Premio%20efficienza%20energetica/Pages/default.aspx
![Page 29: BREVE PRESENTAZIONE DEL RELATORE](https://reader034.vdocuments.mx/reader034/viewer/2022051421/5681641f550346895dd5de57/html5/thumbnails/29.jpg)
CENNI AL SOLARE TERMICOLE POTENZIALITA’ DEL
COLLETTORE SOLARE TEMICO SONO NOTEVOLMENTE PIU’
VANTAGGIOSE DI QUELLE DI UN PANNELLO FOTOVOLTAICO CHE DEVE GESTIRE UN SISTEMA DI
RISCALDAMENTO
![Page 30: BREVE PRESENTAZIONE DEL RELATORE](https://reader034.vdocuments.mx/reader034/viewer/2022051421/5681641f550346895dd5de57/html5/thumbnails/30.jpg)
ESEMPIO DI SISTEMA IMPIANTISTICO
RISCALDAMENTO + ACS
![Page 31: BREVE PRESENTAZIONE DEL RELATORE](https://reader034.vdocuments.mx/reader034/viewer/2022051421/5681641f550346895dd5de57/html5/thumbnails/31.jpg)
IMPIANTI 9SYSTEM
DUE NOSTRE REALIZZAZIONI PRESSO LA CASA DI RIPOSO DI GROTTAGLIE E SCUOLA PIGNATELLI DI LIZZANO
![Page 32: BREVE PRESENTAZIONE DEL RELATORE](https://reader034.vdocuments.mx/reader034/viewer/2022051421/5681641f550346895dd5de57/html5/thumbnails/32.jpg)
GRAZIE PER L’ATTENZIONE