Download - Asgard Centurion Plus 2 Shed Instructions
Drill through the four holes in the base of the unit using 6mm dia masonry drill to a depth of 70mm. Screw in the anchor fixings. (These have a self cutting thread). If not anchoring the unit, fit the self seal plugs BEFORE BUILDING to seal the fixing holes from underneath.
Please note product must be bolted down to comply with LPS1175.
TOOLS REQUIREDPower driver POSI-DRIV screwdriver, 6mm dia. masonry drill and a13mm socket spanner.
CENTURION PLUS 2BASE INSTRUCTIONSFlat and firm base. Recommended: concrete, tarmac or paving flags. Min. distance from walls/ shrubbery: 1000mm.Min. base size (WxDxH) 4940mm x 1730mm x 50mm.
LEVELING THE UNITCorrectly level the constructed unit using the shims (ZCOMPPLAS) provided prior to fixing the unit to the ground. Slide the packing pieces under the corners of the unit base as required until an equal gap has been achieved around the door allowing for its smooth operation and alignment.
Warning: panels weigh over 20KgBeware of manual handling
6mm Dia.
13mm Spanner
18V
For maintenance instructions of this product visit www.asgardsss.co.uk
x2
SEAL
ANT
LH R. SIDE PANEL
32874 x1
LH EXT. SIDE PNL
32853 x2
F. BASE PNL
32940 x1
R. BASE PNL
32871 x1
EXT BASE PNL
32850 x2
LH
DO
OR
3294
3 x1
RH
DO
OR
3294
4 x1
FRONT FASCIA32948 x1
ZSC
REW
32 x
16
ZSIL
CO
1 x3
ZSC
REW
04 x
4
ZSC
REW
100
x36
8
ZSC
REW
340
x24
3267
0 x
24
ZCO
MPP
LZS0
2 x
16
ZCO
MPP
LAS2
2-23
-24
x24
8x 2
mm
, 8x
3mm
, 8x
5mm
BASE
CO
VER
CH
ANN
EL 3
7364
x3
SID
E C
OVE
R C
HAN
NEL
329
16 x
6
RO
OF
CO
VER
CH
ANN
EL
329
18 x
6
RH F. SIDE PNL
32942 x1
RH EXT. SIDE PNL
32854 x2
LH
BAC
K PA
NEL
3286
7 x1
RH
BAC
K PA
NEL
3287
6 x1
TOP SHROUD
32945 x2
EXT. TOP SHROUD
32996 x2
RH R. SIDE PNL
32875 x1
F. TOP PANEL
32986 x1
R. TOP PANEL
32987 x1
EXT. TOP PANEL
32927 x2
LH F. SIDE PANEL
32941 x1
Warning: Please keepthis key card safe! Referto if replacement key is required.
00001
YOUR UNIQUEKEY CODE
ROOF JOINT
STRIP 40446 x6
RH
BAC
K PA
NEL
3287
6
RH
R. S
IDE
PAN
EL32
875
REAR BASE PANEL
32871
x15
1
3
5 6
4
2
x18 x22
x10
PLEASE NOTE ALL SCREWS ARE FIXED FROM THE INSIDE
LH R
. SID
E PA
NEL
3287
4
x16 x13
R. T
OP
PAN
EL32
987
EXT. BASE PANEL
32850 x1
LH B
ACK
PAN
EL32
867
x3
x15
x7
x15
x3
x15
x7
x13
x4
x4
x4x4
7 8
9 10
11 12
x44 x22
x13 x44
x6 x30
LH E
XT. P
ANEL
3285
3
RH EXT. PANEL
32854
x7
x15
x15
x4
x7
x7
x4
x7
x13
EXT. TOP PANEL
32927
F. TOP PANEL
32986
REPEAT 6-8
x4
x4x4
x4x7
x7
F. BASE PNL
32940
RH
F. S
IDE
PNL
3
2942
LH F
. SID
E PA
NEL
3294
1
FRONT FASCIA
32948
x15
x15
x7
x7
x3
x3
www.asgardsss.co.uk
13 14
15 16
17 18
x16
054366/26.08.15/KW/REV0054366/29.09.15/KW/REV1
REMOVE SCREWS WHICH ALIGNWITH THE COVER CHANNELS. ALIGN AND PLACE SCREWS BACK!
BASE
CO
VER
CH
ANN
EL 3
7364
1ST TOP SHROUD
32945
2ND TOP SHROUD
32945
x4
x3
x3
x2
x2
x3x4
x4
x4
x3x3x3
x3
x3
ROOF JOINT STRIP 40446
APPLY TO BOTH
EXT. TOP SHROUDS
32996
SHROUDS 32996 & 32945
ROOF JOINT STRIP 40446
LH D
OO
R32
943
RH
DO
OR
32
944
x24
x24
x12
ROOF JOINT STRIP END40446
3267
0
SID
E C
OVE
R C
HAN
NEL
329
16
RO
OF
CO
VER
CH
ANN
EL 3
2918
ROOF STRIP