Up to 144 fibers
High resistance to tracking effect provides long operating lifetime
SZ stranding design allows for easy mid-span access and isolates fibers from installation and environmental rigors
Drycore design for excellent water blocking performance and easier handling
Minimized additional loads due to small diameter and lightweight with the high strength aramid yarns
Custom designs available ***
Complies with IEEE P-1222, the recognized standard for ADSS cable*** The sheath material (MDPE or TRPE) and the location of the cable on structures that support 110KV or higher circuits should be reviewed prior to installation.
Loose Tube ADss CAbLe_AeriALSAMSUNGs ADSS Cables are designed for installation on wooden poles, concrete poles or lattice towers along power lines, railways or telecommunication links. As the cable does not contain any metallic elements, it is to be installed on medium and high voltage lines, to prevent dry-band arcing. Track resistant sheath material and software to calculate optimum placement on the towers make this cable usable for line voltages of up to 400 KV.
SAMSUNG OPTICAL CABLE
All Dielectric Self-Supporting Cable
Gel-filled buffer tube Colored optical fiber Dielectric central member Water swellable tape Water swellable yarn Inner jacket Dielectric strength member Outer jacket
*** Drawings are not to scale.
singLe JACkeT TypeFiber Count 2 ~ 36 2 ~ 72 74 ~ 96 144
Outer Diameter (mm) 11.4 12.2 13.9 15.8
Cable Weight (kg /km)MDPE 100 114 147 192
TRPE 107 122 156 201
Maximum operating load (kN) 4 4 4 6
Maximum breaking load (kN) 13.0 13.6 14.0 15.4
Minimum bending radius (mm)
Short term (loaded): 15*OD 171 183 209 237
Long term (installed): 10*OD 114 122 139 158
Temperature (C)Operation / Storage -40 ~ +70
Installation -20 ~ +70
DoubLe JACkeT TypeFiber Count 2 ~ 36 38 ~ 72
Outer Diameter (mm) 12.9 14.1 15.3 16.2 13.8 14.8 15.8 16.8
Cable Weight (kg /km)MDPE 128 151 176 199 144 166 189 212
TRPE 137 161 186 210 154 176 200 224
Maximum operating load (kN) 4 12 20 28 4 12 20 28
Maximum breaking load (kN) 13.4 35.7 59.9 82.8 14.0 35.1 58.1 81.0
Minimum bending radius (mm)
Short term (loaded): 15*OD 194 212 230 243 207 222 237 252
Long term (installed): 10*OD 129 141 157 162 138 148 158 168
Temperature (C)Operation / Storage -40 ~ +70
Installation -20 ~ +70
Fiber Count 74 ~ 96 98 ~ 144
Outer Diameter (mm) 15.4 16.3 17.3 18.1 19.2 19.9 20.7 21.4
Cable Weight (kg /km)MDPE 180 202 225 247 280 302 323 345TRPE 190 213 237 260 293 316 338 360
Maximum operating load (kN) 4 12 20 28 8 16 24 32
Maximum breaking load (kN) 13.2 35.5 58.5 81.5 23.1 46.5 69.5 92.6
Minimum bending radius (mm)
Short term (loaded): 15*OD 231 245 230 272 288 299 311 321
Long term (installed): 10*OD 154 163 157 181 192 207 207 214
Temperature (C)Operation / Storage -40 ~ +70
Installation -20 ~ +70
Tested in accordance with IEC 60794-1
noTe Fiber colors by IEC60304 - Blue / Orange / Green / Brown / Grey / White / Red / Black / Yellow / Violet / Pink / Aqua Diameter represents a nominal value and may vary by 5%. Sheath marking legend - hot foil stamp (indented)
Ex) Manufacturing year (ex. 2013) SAMSUNG ADSS SM 24 = length marking =