K3 reader adopts Fujitsu PalmSecure technology and also embedded Bluetooth and different kinds of contactless smart card technologies, it becomes a perfect design for true-contactless and high accuracy Bio-metrics, contactless smart card, mobile device cross-pla�orm applica�on.
Fujitsu PalmSecure technology is a palm vein based authen�ca�on solu�on that u�lizes industry-leading vascular pa�ern biometric technology. The Fujitsu PalmSecure sensor uses near-infrared light to capture a person's palm vein pa�ern, genera�ng a unique biometric template that is matched against pre-registered user palm vein biometric templates.
ACX K3 reader is water proof design that suitable for different indoor and outdoor installa�on environment, it made by high quality material to ensure enhanced reliability and long-term dura�on.
Reader has wiegand and scrambe encryp�on output which suitbale for differnet security level applica�ons.
Embedeed bluetooh technology can read the encrypted virtual creden�al number from Android phone and iPhone.
• Waterproof IP65• Fujitsu PalmSecure, Bluetooth and Contactless Smart Card Technology• Op�cal sensor for tamper protec�on, I am alive feature• Supports 125KHz, 13.56MHz ISO 14443 A, B & ISO15693, Bluetooth 4.0• RED / Green / Blue or mixed color LED Circle Ring for visual no�fica�on• User defined reader's access granted and access denied LED & Buzzer ON / OFF �mes and interval• Wiegand and ACX proprietary scramble encryp�on RS485 format
DESIGN ∙ INNOVATIONS
KEY FEATURES
8200 Palm Vein Controller
Palm Vein Sensor
Card Technology HID iCLASS HID 125KHz EM Mifare Classic
Card number output 32 ~ 64 bits CSN HID card number 32 bits CSN 32 ~ 56 bits CSN / Sector
Item No. ( RF / RF+BLE ) 6811 / 68T1 6812 / 68T2 6813 / 68T3 6814 / 68T4
Card Technology SONY Felica CSN Mifare Plus S/X Mifare DESFire EV1 LEGIC Advant / Prime
Card number output 32 ~ 64 bits CSN 32 ~ 56 bits CSN / Sector 32 ~ 56 bits CSN / File 32 ~ 64 bits CSN / Sector
Item No. ( RF / RF+BLE ) 6815 / 68T5 6816 / 68T6 6817 / 68T7 6818 / 68TB
Palm Vein Controller
Key Authentication
Card Data Security
Reader output
Typical Read Range
I am alive
Reader cable
Mounting
Visual indicator
Audio indicator
Color
Dimension
Product weight
Operating Voltage
Operating Current
Operating Temperature
Storage Temperature
Operating Humidity
Housing Material
Cable Distance
Fujitsu PalmSecure-Pro F, I33-format
Works with ACX 8200 Palm Vein Controller
Wall Switch Size; designed to mount and cover single gang switch boxes primarily used in the Americasand includes a slotted mounting plate for European and Asian back box spacing
5 meters CAT 6 cable connects to ACX 8200 Palm Vein Controller
Circle Ring in RED / Green / Blue / Amber / Purple / White / Light Purple color, user defined LED ON / OFF time interval
Internal buzzer, user defined beep sound ON / OFF time interval (ms)
Black or White
-67º to 185º F (-55º to 85º C)
5% to 95% relative humidity non-condensing
80 mm x 115 mm x 20 mm
9-16 VDC, Linear supply recommended
130g
RS485 interface: 4000 feet (1200 m)Recommended cable is ALPHA 1295 (22 AWG) 5 conductor minimum stranded with overall shield or equivalent
K3 Palm Vein multi-technologies Reader
Palm Vein : 35mm ~ 70mm, 125KHz : 5cm+, 13.56MHz : 4cm+, Bluetooth Technology : 2m to 10mTypical read range achieved in air; different types of metal will cause some degradation
Use spacers to space product off metal and improve read range if required.
ACX Propriatery scramble RS485 output and wiegand output
Max. 64 bits card number mixed with original CSN, custom AES 128 bits key data encryption, CRC16
Custom 128 bits diversify key
User define 1 bytes "I am alive" data in a certain interval
Polycarbonate
150mA AVG, 120mA PEAK
- 31º to 150º F (-35º to 65º C)
8200 Palm Vein Controller
KEY FEATURES
• Integrated with Palm Vein Sever
• Works with K3 Palm Vein Reader
• 1 : N palm vein template matching
• Wiegand and Scramble RS485 interface output
• Scramble data encryption between PANEL
and Palm Vein Server
• True TCP/IP, high speed communication
PC to Panel
Max. Panel
Wiring Methods
TCP/IP, 100Mbs with 128 bits custom key for random encryp�on
Depends on IP address available
Panel to Switch, CAT 5 cable (max. 100 meters)
1 x ACX K3 Palm Vein Reader (CAT 6 cable)
1 x Wiegand output (6~8 wires)1 x ACX scramble RS485 outut (4 wires)
Connect to ACX Pal Vein Server (CAT 5 cable)
Communica�on
Inputs / Outputs
Panel Inputs
Panel Output
TCP/IP
Specification
12VDC, 3A input
Power supply
Others
Opera�ng Voltage
Opera�ng Temperature
Opera�ng humidity
Dimension
0° to 65° C
0-95% rela�ve humidity non-condensing
180mm x 120mm x 20mm
Bluetooth virtual card technology
Fujitsu Palm Vein Technology
ACX K3multi-technologies reader
13.56MHz smart card technology
Wiegand output
Wiegand Input
Door Access Panel
ACX IP basedDoor Access Panel
8200 Palm Vein Controller
RS485 interface(Scramble encryption)
ACXPalm Vein Server
ACXPalm Vein Server
Local Area Network
Palm Vein CollectorUser PC
User’s Palm Vein Templates stored in SERVER
8200 8200 8200
USB
Palm Vein Access Control Solution