SUPER QUIET GENERATORSG
EN
ER
ATO
RS
SU
PE
R Q
UIE
T
FEATURES
• Prime output ratings from 25 kVA to 267 kVA.
• Quiet operation: 68 dba or less at 23 ft. (7 m).
• High water temperature, low oil pressure,overspeed, and safety shutdown.
• Generator output is monitored by anovercurrent relay which works with ashunt trip breaker system to protect the unit.
• Spin-on diesel water separator effectivelyhandles filtration.
• Engine control panel comes with fullanalog gauge package on all models,including digital Tier 3.
• Engine control module includes remotestart capability on all models.
• Solid state electronic governor results instable engine response to load changes.
• Environmentally friendly fuel base servesas solid foundation and stores over 24hours of fuel capacity. Designed to keepoil, antifreeze and other spills inside the unit.
• 3-position voltage selector switch allowsunit to provide 240 and 480 volt threephase and 240 volt single phase.
• DOT approved and serialized trailers.Hydraulic brakes, full light package, bolton fenders and heavy duty side-mountjacks are standard.
7885_109131_sq_gen_fam 1/17/07 7:15 PM Page 263
THE STRENGTH OF MANY. THE POWER OF ONE.
What’s in a name? Plenty when that name is Terex. In the
business of helping you grow your business, Terex has
brought together leading equipment manufacturers from
throughout the world under one brand — all focused on
delivering technologically advanced and ruggedly reliable
solutions for the construction, infrastructure, quarry,
recycling, mining, shipping, transportation, refining, utility
and maintenance industries. Terex is dedicated to
manufacturing innovative equipment proven to enhance
efficiencies, increase productivity and boost bottom lines.
In fact, Terex products are purposely designed to
maximize your return on investment.
Terex equipment is no exception.
Offering a safe, cost-effective, easy to use and
highly-productive line of light towers, power
generators and concrete accessories, Terex tools
help you get the job done — on time and on budget.
But before you can finish the job, you need to get
the job. That means being in the right place at the
right time with the right equipment. Enter Terex
Financial Services, offering a full spectrum of unique
and competitive financing options, our industry
experts stand ready to help you get your hands on
the equipment you need to succeed.
And that’s just the beginning.
Terex backs its products with a world-wide network of
distributors who know your business inside and out.
Partner with Terex and you’ll have access to local and
dedicated service and support teams before, during and
long after the sale. Add it all up for a return on investment
you can take to the bank.
Don’t take our word for it — put Terex Super Quiet
Generators to the test and you’ll see what we mean.
The T120 Super Quiet
Generator offers prime
output rating of 119 kVA,
68 dba and 196 gal. fuel
capacity.
7885_109131_sq_gen_fam 1/17/07 8:02 PM Page 264
SUPER QUIETPERFORMANCE User friendly control panel assembly consists of all
analog readout gauges. DC engine gauges monitor water
temperature, oil pressure, engine hours, fuel level and battery voltage.
Power output AC gauges indicate generator volts, hertz and amperes.
The engine control module monitors the status of the engine and if
necessary, shuts it down under a fault condition. A voltage adjust
potentiometer is easily accessible from the panel allowing the unit to
operate at various voltages. The power output side of the panel
consists of a main 3 phase breaker, 2 GFCI duplex receptacles, and
2 or 3 Tempower twistlock receptacles (50 amps) depending on unit
size. Convenience receptacles remain live regardless of the voltage
selector switch position.
3-position voltage selector switch is
standard. Terex Super Quiet generators provide almost
any three phase or single phase voltage you’ll need.
Switch is lockable to prevent damage by changing
voltages while unit is running.
Utilizing Murphy's new Cascade
controller, Terex Super Quiet generators now come
standard with this automatic engine controller that
works with both J1939 and mechanically controlled
engines. Functions include starting and stopping the
engine in manual or automatic mode, indicating
operational status and fault conditions and automatic
shut down of the engine should a fault occur. The
controller is user friendly and can be easily modified by
using the adjustment buttons located on the front of the
panel. No computer input needed! This new controller
also allows you to standardize your units in your fleet,
and will work with any Tier I, II, III engine and beyond.
An optional Cam Lok distribution panel is available on
all Terex Super Quiet generators. Each individual Cam
Lok connector is rated to 400 amps at 600 volts, and is
designed to meet rugged industry standards. On
models where unit output amperage can exceed the
Cam Lok rating, multiple sets are provided. This panel
can be used simultaneously with the standard 5 lug
distribution board or as a stand alone power source.
This popular, tool-less option, allows you to standardize
and optimize your power distribution needs.
For units that require special options, such as
600/480 volts switchable, Terex Super Quiet
generators offer the Murphy iGuard
controller with Powerview gauges.
This combination of leading edge generator
technology allows the unit to maximize all of the
capabilities and information available with today's
digitally controlled Tier II and III engines, while giving
the operator information in both digital and analog
formats. The programmable engine control module
delivers all the standard safety features you’d expect
from Murphy, as well as meeting both NFPA110 and
NFPA99 requirements. Many other options can be
programmed into the iGuard, allowing you to
customize and monitor the generator as you choose.
7885_109131_sq_gen_fam 1/17/07 8:03 PM Page 265
Super Quiet
GENERATORS
Standard 3 phase distribution
board consists of a 5 lug panel,
with separately mounted ground
connection, and easy to read and
understand main lug connection
diagrams. Convenient brass studs
allow for easy connection of power
load cables using ring terminal, or
bare cable ends when using the
optional bare lug terminal blocks
(not shown).
An electronic governor system is
optional on models up to
50 kVA and standard on models
50 kVA and larger. The
actuator/controller system is
solid state in design and
results in fast, stable engine
response to load changes.
Spin-on type diesel/water
separators have in-head fuel
priming pump and are
specifically designed to handle
today’s tough diesel filtration
problems.
SQGF 5K 1206C Part #109131
Effective date: August 15, 2006. For further information, please contact your local distributor or the Terex sales office listed. Product specifications are subject to change without notice or obligation. The photographs and drawings
in this brochure are for illustrative purposes only. Refer to the appropriate Operator's Manual for instructions on the proper use of this equipment. Failure to follow the appropriate Operator's Manual when using our equipment
or to otherwise act irresponsibly may result in serious injury or death. Prices and specifications subject to change without notice. The only warranty applicable is the standard written warranty applicable to the particular product
and sale. Terex makes no other warranty, expressed or implied. Products and services listed may be trademarks, service marks or trade-names of Terex Corporation and/or its subsidiaries in the USA and other countries and
all rights are reserved. "Terex" is a Registered Trademark of Terex Corporation in the USA and many other countries. Copyright ©2006 Terex Corporation
A Terex company
18340 NE 76th Street PO Box 97030Redmond, WA 98073-9730
TEL 425-881-1800TOLL FREE 800-536-1800PARTS & TECH SUPPORT 800-228-6444FAX 425-883-8475WEB terex.com
Genie Industries, Inc.
For more information, product demonstration, or details on purchase, lease and rentalplans, please contact your local Genie Distributor.
F R O M D I R T T O A I R , T E R E X H A S Y O U C O V E R E D
Partner with Terex and you'll work with the third largest manufacturer of construction and mining equipment in the world. More than 50 time-tested brands
make up the Terex family offering the breadth and depth of products, services and support you need to generate a quick return on investment.
Standard distribution
panel
Spin-on diesel/water
separators
24 hour fuel tank
integral to unit
Service access platesElectronic governor
system (std. on model
T50 and larger)Rear louver panel
assembly
7885_109131_sq_gen_fam 1/17/07 8:04 PM Page 266
Super Quiet Generators
SUPER QUIETGENERATORS
MODEL T25 T45 T50 T70P T70C T90 T120PPOWER CAPABILITY – PRIME
kVA (kilovolt-amps) 25 45 50 68 72 90 113
kW (kilowatts) 20 36 40 54 58 72 90
3 Phase Amp Ratings 208V 69 125 139 189 200 250 314240V 60 108 120 164 173 217 272480V 30 54 60 82 87 108 136
POWER CAPABILITY – STANDBY
kVA (kilovolt-amps) 30 50 54 75 79 100 125
kW (kilowatts) 24 40 43 60 63 80 100
3 Phase Amp Ratings 208V 83 139 150 208 219 278 347240V 72 120 130 180 190 241 301480V 36 60 65 90 95 120 150
Max Motor Starting* Hp 12 18 18 39 39 58 77kW 9 13 13 29 29 43 57
SKVA 70 110 110 235 235 350 460DIESEL ENGINE DATA
Manufacturer Isuzu Isuzu Perkins Perkins Cummins Perkins Perkins
Model 4LE2PV01 4JG1TPV 1104C-44G1 1104C-44TG 4BTA3.9-G5 1104C-44TAG1 1104C-44TAG2
Cylinders 4 4 4 4 4 4 4
Air Intake (aspiration) Natural Turbo Natural Turbo Turbo Turbo Turbo
Cooling System Std Rad Std Rad Std Rad Std Rad Std Rad Rad w/ CAC Rad w/ CAC
Fuel Capacity (gal) 64 64 80 118 118 118 196
Run Time (75% Load) 53 29 33 34 30 32 37SKID MOUNT
Dim (L x W x H - in) 84x39x51 84x39x51 88x40x53 110x44x60 110x44x60 110x44x60 110x44x63
Weight Dry (lbs) 1,900 2,725 3,069 4,157 4,157 5,200 5,200
Weight Full (lbs) 2,354 3,173 3,637 4,995 4,995 6,038 6,592TRAILER MOUNT
Dim (L x W x H) 137x66x68 137x66x68 129x68x73 177x72x77 177x72x77 177x75x80 177x75x80
Weight Dry (lbs) 2,375 3,200 4,185 4,980 5,357 6,697 6,697
Weight Full (lbs) 2,829 3,648 4,745 5,806 6,195 7,535 8,089MISCELLANEOUS
dBA @ 23 ft (7 m) 67 65 66 66 66 66 68
Controller Type Analog Analog Analog Analog Analog Analog Analog
*Maximum motor size is based on 35% voltage dip at 480 VAC 3 phase 60Hz with a code G motor.
7885_109069_sq_gen 1/17/07 10:06 PM Page 268
SPECIFICATIONS
MODEL T120C T180 T270POWER CAPABILITY – PRIME
kVA (kilovolt-amps) 119 181 267
kW (kilowatts) 95 145 214
3 Phase Amp Ratings 208V 330 502 741240V 286 435 642480V 143 218 321
POWER CAPABILITY – STANDBY
kVA (kilovolt-amps) 132 200 329
kW (kilowatts) 106 160 263
3 Phase Amp Ratings 208V 366 555 913240V 318 481 791480V 159 241 396
Max Motor Starting* Hp 77 113 152kW 57 84 98
SKVA 460 680 850DIESEL ENGINE DATA
Manufacturer Cummins Cummins Cummins
Model 6BTA5.9-G4 QSB7-G3 Q5L9-G2
Cylinders 6 6 6
Air Intake (aspiration) Turbo Turbo Turbo
Cooling System Std Rad Rad w/ CAC Rad w/ CAC
Fuel Capacity (gal) 196 238 300
Run Time (75% Load) 31 25 23SKID MOUNT
Dim (L x W x H - in) 110x44x63 131x50x67 144x50x87
Weight Dry (lbs) 5,390 7,850 8,580
Weight Full (lbs) 6,782 9,540 10,680TRAILER MOUNT
Dim (L x W x H) 177x75x80 184x68x82 206x84x106
Weight Dry (lbs) 6,887 9,290 10,460
Weight Full (lbs) 8,279 10,980 12,560MISCELLANEOUS
dBA @ 23 ft 68 68 68
Controller Type Analog Analog Analog
*Maximum motor size is based on 35% voltage dip at 480 VAC 3 phase 60Hz with a code G motor.
Super Quiet
GENERATORS
Specifications
SQGS 5K 1206G Part #109069
A Terex company
18340 NE 76th Street PO Box 97030Redmond, WA 98073-9730
TEL 425-881-1800TOLL FREE 800-536-1800PARTS & TECH SUPPORT 800-228-6444FAX 425-883-8475WEB terex.com
Genie Industries, Inc.
For more information, product demonstration, or details on purchase, lease and rentalplans, please contact your local Genie Distributor.
Effective date: August 15, 2006. For further information, please contact your local distributor or the Terex sales office listed. Product specifications are subject to change without notice or obligation. The photographs and drawings
in this brochure are for illustrative purposes only. Refer to the appropriate Operator's Manual for instructions on the proper use of this equipment. Failure to follow the appropriate Operator's Manual when using our equipment
or to otherwise act irresponsibly may result in serious injury or death. Prices and specifications subject to change without notice. The only warranty applicable is the standard written warranty applicable to the particular product
and sale. Terex makes no other warranty, expressed or implied. Products and services listed may be trademarks, service marks or trade-names of Terex Corporation and/or its subsidiaries in the USA and other countries and
all rights are reserved. "Terex" is a Registered Trademark of Terex Corporation in the USA and many other countries. Copyright ©2006 Terex Corporation
General Features for All
Terex Power Super Quiet
Generators
Super Quiet Operation
68 dBA or less - varies by model
Generator Type
Brushless, 4 Pole, Synchronous, SingleBearing, 1800 rpm, Class H Insulation, PMGon models T70 and up
Voltage Selector
High Wye, Low Wye, Zig Zag
Voltage - 3 Phase
208, 220, 240, 416, 440, 480 (optional 600V)
Voltage - 1 Phase
120, 127, 139, 240, 254, 277
Convenience Receptacles
2 each 20 A GFCI duplex receptacles and 2each 50 A Tempowers on all units,1 additional Tempower on T50 and up
Voltage Regulation
AVR and PMG (± 1 %) T70 and up, AVR only(± 1.5 %) T50 and down
Speed Control (governor)
Electronic (± 0.5 %) T50 and up, MechanicalStandard (5 %) T45 and down
Start/Stop Controller
Murphy Cascade Controller standard on allmachines
Available Trailers
T25 and T45 - no brakes or electric brakes,T50 to T270 - hydraulic surge brakes orelectric brakes
Trailer Hitch Options
Pintle Ring is standard, 2-5/16" Ball and 2"Ball available for extra charge
7885_109069_sq_gen 1/17/07 10:07 PM Page 269