Download - 68020564373_Orbit
Transcript
After probe replacement:
UOD1 - B.F.W. Pump.Bently
YP-01-B-be - PIX vs PIY
Orbit Display
14-Feb-15 09:00:23
(Filtr- 1xRPM Syn)
P-PX= 6.40
P-PY= 9.20
LOAD = 100.0
RPM = 4745. (79.09 Hz)
-6
-3
0
3
6
-6
-3
0
3
6
PIX in Microns
PIY in Microns
Rev :
AmpX:
AmpY:
.316
3.164
4.642
Before probe replacement:
UOD1 - B.F.W. Pump.Bently
YP-01-B-be - PIX vs PIY
Orbit Display
07-Jan-15 14:09:46
P-PX= 15.20
P-PY= 42.33
LOAD = 100.0
RPM = 4748. (79.13 Hz)
-30
-20
-10
0
10
20
30
-30
-20
-10
0
10
20
30
PIX in Microns
PIY in Microns