1
2
4
5
6
7
8
9
Introduction
Gutter Profile Selector
Classic
Flowline
100m Half Round
125mm Half Round
Clipmaster
Deepflow
10150mm Industrial
1175mm Miniline
1268mm Circular Downpipe
1481mm Circular Downpipe
15110mm Circular Downpipe
1665mm Square Downpipe
17Universal Fittings
Installation Instructions
18- Notched Gutter Systems
19- Plain Ended Gutter Systems
20- Rainwater Pipes
Contents
6395 MFP Rainwater single pgs 12/11/2004 14:42 Page 1
The CompanyMFP is a leading producer of quality plastic building products for theconstruction industry, public utilities and local authorities. Established in1967, the company is part of the Grafton Group plc.
Product RangeThe comprehensive MFP range of drainage products is a result of manyyears of research and development and includes many technicalinnovations which simplify work on site, improve performance and reduceinstallation costs. MFP offers a complete range of gutter systems,designed to enhance the aesthetics as well as satisfy the requirements ofall types of building, whether domestic, industrial, commercial or public.The systems are available in various sizes in half-round, semi-elliptical,square and ogee profiles and in a variety of colours.
StandardsMFP Rainwater systems are manufactured to conform to appropriatespecifications and standards.MFP operates a quality system conforming to I.S. EN ISO 9002 : 1994which involves regular third party inspection of manufacturer’s works.
AdvantagesMFP gutter systems are tough and of proven durability, while lightweightand easy to handle and install. Their simple method of jointing meansthat they can easily be removed or extended. Available in a variety ofcolours and profiles, chosen to compliment any building design, they arecorrosion free and require minimal maintenance. These advantages,together with their cost-effectiveness, offer a better choice in terms ofperformance and aesthetic appeal.
Technical AdviceA technical advisory service is available to give guidance on design andthe correct use of all MFP products. MFP rainwater systems in PVCuform part of a wider range of drainage installations for soil and wastedischarges and underground drainage and sewerage systems. Literaturedescribing all of these products is available on request.
1
6395 MFP Rainwater single pgs 12/11/2004 14:42 Page 1
2
FlowlineClassic
Choice of GutterThere are a number of points toconsider when choosing a guttersystem for a particular building. Thecarrying capacity of a system is ofprime importance, but one must alsoconsider the colour and profiles bestsuited to enhance the building, theease of installation and possiblesubsequent extension or alteration,and whether one uses square orround downpipes.
Design DirectivesIrish Building Regulations 1997requirements are set out in TechnicalGuidance Document H, Drainage andWaste Disposal, sub-section 1.5(Surface Water Drainage).
U.K. Building Regulations 2000requirements are set out in ApprovedDocument H, Drainage and WasteDisposal, part H3 RainwaterDrainage, 2002 Edition.
BS EN 12056-3: 2000 - gravitydrainage inside buildings: roofdrainage layout and calculation, givesdetailed recommendations on designand should be consulted if conditionsother than normal are expected.
Rainfall IntensityIt is generally accepted that thecalculation of roof drainage is basedon a rainfall intensity of 75mm perhour. Statistics show that rainfall ofhigher intensity has beenexperienced rarely and for very shortperiods of time. This factor, however,should be considered if it isimperative that overflow be totallyavoided.
Effective Roof AreaIn the case of a flat roof (includingsloping roofs of less than 10° pitch)the effective roof area is the area onplan of the portion of roof to bedrained. For pitched roofs, however,allowance must be made for thevarying angles of rainfall whichincreases its intensity.
The method of calculation fordetermining the area of such roofs isas follows:-L = Length of RoofH = Vertical height of RoofW = Width of Roof sectionEffective roof area M2 = (L x W) + (L x )
Rainfall Run-offTo calculate the rainfall run-off inlitres per second it is necessarysimply to multiply the Effective RoofArea by a factor of 0.0208 (based ona rainfall intensity of 75mm perhour).
Carrying CapacityThere are a number of factorsaffecting the carrying capacity ofgutters. The principal ones arewhether or not the gutters are laid toa fall and whether the outlet isplaced at the centre of the run or atone end. Flow rates are also affectedby the type and configuration of thedownpipe system being used and,for the purpose of our calculations,all figures shown in the performancetable are based on using 68mmcircular downpipe with a 300mm offset, fitted with unsealed joints directly to the gutter outlet.
Thermal MovementThe coefficient of linear expansion ofPVCu is 6 x 10-5/°C which meansthat gutters and downpipes mayexpand or contract up to 0.6mm permetre per 10°C change oftemperature. All gutter systemscontained in this brochure havebeen designed to take account ofthis movement. It is important,therefore, that these systems areinstalled in accordance withinstallation instructions on pages 18& 19.
Snow LoadingAll of the gutter systems in thisbrochure have been subjected tosimulated snow loading tests as, orsimilar to, the test for resistance toload detailed in BS4576: Part 1 andperform in excess of requirements.Recommendation for installations inareas of severe snowfall, where itmay be necessary to fit snow boardsat eaves of pitched roofs to protectagainst damage or injury, are givenin BS EN 12056-3: 2000.
2
h2
H
WL
Gutter ProfileSelector
6395 MFP Rainwater single pgs 12/11/2004 14:42 Page 2
3
Chemical PropertiesPVCu gutter systems are corrosionfree and because they are selfcoloured, they will never requirepainting. If, however, paintingshould be desired, an oil basedalkyd paint is recommended(standard gloss paint). Timberfascias which have been treatedwith wood preservative should beallowed to dry thoroughly beforefixing gutter systems.
HandlingPVCu gutters and pipes are strong,though lightweight, and aretherefore easily handled. However,reasonable care should be exercisedwhilst handling in extremely coldconditions. It is advantageous topreserve the appearance of theseattractive self-coloured materials.When products are delivered to site,therefore, they should, preferably,be placed inside a storage building.
StorageGutters and pipes should be wellsupported on suitable racks.Dividing the framework or shelvesinto sections helps to segregatedifferent products and preventsoverloading and possible distortionof bottom layers.
Pipes and gutter bundles should bestacked no more than seven high. Ifit is necessary to store in the openfor long periods, or if products are tobe exposed to strong sunlight, theyshould be covered with an opaquesheet. Fittings supplied in cardboardboxes or polythene bags should bestored under cover and kept packeduntil required.
Solvent cement must be securelystored in a cool place out of directsunlight and away from any heatsource.
Performance TableOutlet at one end Outlet at centre
Profile GUTTER LAID LEVEL GUTTER LAID TO FALL 1/600 GUTTER LAID LEVEL GUTTER LAID TO FALL 1/600CAPACITY AREA CAPACITY AREA CAPACITY AREA CAPACITY AREA
100mm Half-Round 0.77 l/s 37 M2 0.92 l/s 44 M2 1.51 l/s 72 M2 1.81 l/s 86 M2
125mm Half-Round 1.14 l/s 54 M2 1.36 l/s 65 M2 2.10 l/s 100 M2 2.54 l/s 122 M2
112mm Clip Master 0.90 l/s 43 M2 1.00 l/s 48 M2 1.75 l/s 84 M2 1.92 l/s 92 M2
Deepflow 1.83 l/s 87 M2 2.21 l/s 106 M2 3.51 l/s 168 M2 4.21 l/s 202 M2
Flowline 1.46 l/s 70 M2 1.75 l/s 84 M2 2.92 l/s 140 M2 3.50 l/s 168 M2
Classic 2.16 l/s 103 M2 - - 4.15 l/s 199 M2 - -
Industrial 2.41 l/s 115 M2 2.89 l/s 138 M2 4.83 l/s 231 M2 5.80 l/s 278 M2
Miniline 0.33 l/s 16 M2 0.40 l/s 19 M2 0.54 l/s 26 M2 0.64 l/s 31 M2
l/s: Run-off in litres per secondArea= Maximum roof area to be drained
Deepflow Industrial MinilineHalf Round Clip-Master
6395 MFP Rainwater single pgs 12/11/2004 14:42 Page 3
Classic
4
Gutter Running Outlet
Fascia Bracket
RCG 54 4 Metres RCO 50
Connects to both 68mm circular/65mm square downpipe
ColoursBlackWhiteChestnut brown
Downpipe size65mm Square68mm Circular
Installation Method see Page 19
120mm x 75mm
Classic is a bold highlydecorative ogee stylerainwater systemincorporating uniqueinjection moulded dryjointing seals. Classicoffers a choice of externalor concealed internalfascia brackets and eithercircular or squaredownpipe. All Classicfittings are suppliedcomplete with straps andseals. Outlets, angles andunions incorporate screwfixing points to anchor thesystem and control theeffects of thermalmovement
Angle 45°
Union
RCO 51Left Hand
RCO 52Right Hand
RCU 51
120
75
Connects to both 68mm circular/65mm square downpipe
RCA 511External
RCA 522Internal
Angle 90°
External Stopend
RCE 51Left hand
RCE 52Right Hand
Spare Clip
RCC 51
Stopend Outlet
RCA 51External
RCA 52Internal
Code Length Code
Code Code Code
Code Code Code Code
Code Code Code Code
Code
Angle 30°
RCA 510External
Code
RCK 51 External
RCK 52ConcealedCarrying Capacity
Outlet at one end GUTTER LAID GUTTER LAID TOLEVEL FALL 1/600
L/S Area L/S Area 2.16 103 - -
Outlet at centreGUTTER LAID GUTTER LAID TOLEVEL FALL 1/600
L/S Area L/S Area4.15 199 - -
Area= M2
L/S= Litres per second
6395 MFP Rainwater single pgs 12/11/2004 14:42 Page 4
Flowline
5
Gutter Running Outlet
Stopend OutletUnion Bracket
Fascia Bracket
External Stopend
Gutter Angle 90°
RGF 4 4 Metres
RUF 1
RKF 2
REF 2
RAF 1
ColoursBlackWhiteChestnut brown
Down Pipe size65mm Square68mm Circular
Installation Method see Page 19
116mm x 60mm
Flowline is anattractive box sectionprofile rainwatersystem. Capable ofcarrying capacities inexcess of standardhalf round gutters.Flowline is theaesthetic choice forlarger roof areas.
60
116
Gutter Angle 45°
RAF 2
ROF 1 Square
ROF 2Circular
Spare Clip
RCF 1
ROF 11Square
ROF 21Circular
Code Length
Code
Code Code
Code Code
Code Code
Code Code
Code
Carrying CapacityOutlet at one end GUTTER LAID GUTTER LAID TOLEVEL FALL 1/600
L/S Area L/S Area 1.46 70 1.75 84
Outlet at centreGUTTER LAID GUTTER LAID TOLEVEL FALL 1/600
L/S Area L/S Area2.92 140 3.50 168
Area= M2
L/S= Litres per second
6395 MFP Rainwater single pgs 12/11/2004 14:42 Page 5
6
ColoursBlack
Grey
White
Chestnut brown
Slate grey
6
Gutter Running Outlet
Gutter Strap
Fascia Bracket
Stopend Outlet
Stopend - Internal
Stopend - External
Union Clip
RGH 402 2 MetresRGH 403 3 MetresRGH 404 4 Metres
RD 40
RO 401
RK 401
RO 402
RE 401 RU 40
Downpipe size68mm Circular
Installation Method see Page 18
100mm Half Round
The traditionalappearance of the100mm Half RoundGutter combines withits ease of installationto make it a costeffective and efficientgutter system to suitmost domesticsituations.
Manufactured toBS4576: Part 1 1989
100
48
Gutter Angle
RA 404 90°
RA 405120°
RA 406135°
Code Length
Code Code
Code
RE 402Code
Code
Code Code Code Code
Code
Carrying CapacityOutlet at one end GUTTER LAID GUTTER LAID TOLEVEL FALL 1/600
L/S Area L/S Area 0.77 37 0.92 44
Outlet at centreGUTTER LAID GUTTER LAID TOLEVEL FALL 1/600
L/S Area L/S Area1.51 72 1.81 86
Area= M2
L/S= Litres per second
100mm Half Round
ColoursBlack
6395 MFP Rainwater single pgs 12/11/2004 14:42 Page 6
ColoursBlack
Downpipe size68mm Circular81mm Circular
Installation Method see Page 18
125mm Half Round
125mm Half Round
The 125mm HalfRound Gutter has thesame traditionalappearance as the100mm, and its costeffectiveness togetherwith its greatercarrying capacitymakes it the idealsystem for largerroofs.
Manufactured toBS4576: Part 1 1989
Gutter
Gutter Angle
Running Outlet
Gutter Strap
Fascia Bracket
Stopend Outlet
Stopend - Internal Union Clip
RGH 502 2 MetresRGH 503 3 Metres
RA 504 90°
RA 505120°
RA 506135°
RO 501 68mm DropRO 503 81mm Drop
RK 501
RO 502 68mm DropRO 504 81mm Drop
RE 501
125
55
Stopend - External
RE 502
7
RD 50
RU 50
Code
Code Length
Code
Code
Code
Code
Code Code Code Code
Code
Outlet at centreGUTTER LAID GUTTER LAID TOLEVEL FALL 1/600
L/S Area L/S Area2.10 100 2.54 122
Area= M2
L/S= Litres per second
Carrying CapacityOutlet at one end GUTTER LAID GUTTER LAID TOLEVEL FALL 1/600
L/S Area L/S Area 1.14 54 1.36 65
6395 MFP Rainwater single pgs 12/11/2004 14:42 Page 7
Clip-Master
8
Gutter
Gutter Angle 90°
Running Outlet
Union bracket
Fascia Bracket
Stopend Outlet
Gutter Angle 45°External Stopend
Spare Clip
RGC 4 4 Metres
RAC 1
RUC 1
ROC 1
RKC 1
ROC 2
RAC 2REC 1
RCC 1
ColoursBlackGreyChestnut brownWhite
Downpipe size68mm Circular
Installation Method see Page 19
112mm Half Round
Clip-master is apractical, easy to installhalf round rainwatersystem. Designed for fast,easy installation, Clip-master features pre-fittedloose clips on all fittingsensuring positive ‘clip’jointing. Clip-master isnot only very costeffective but connects tomost other manufacturers’half round systems.
Manufactured toBS4576: Part 1 1989BS EN 607:1996
112
49
Code Code
Code
Code
Code
Code Code
Code Length Code
Carrying CapacityOutlet at one end GUTTER LAID GUTTER LAID TOLEVEL FALL 1/600
L/S Area L/S Area 0.90 43 1.00 48
Outlet at centreGUTTER LAID GUTTER LAID TOLEVEL FALL 1/600
L/S Area L/S Area1.75 84 1.92 92
Area= M2
L/S= Litres per second
6395 MFP Rainwater single pgs 12/11/2004 14:42 Page 8
9
RET
Deepflow
9
Gutter
Fascia Bracket
Stopend Outlet
Gutter Angle 45°
Gutter Angle 90°
RGD 4 4 Metres
RUD 10
ROD 10
RKD 1
ROD 20
RAD 20
RAD 10
ColoursBlackGreyChestnut brown
Downpipe size68mm Circular
Installation Method see Page 18
110mm x 75mm
Deepflow was thefirst semi-elipticalprofile rainwatersystem. TheDeepflow profileproduces a self-cleansing flowresulting in a veryhigh capacity.
Manufactured toBS EN 607:1996
110
75
External Stopend
RED 10
Code Length Code
Code Code
Code Code
Code Code
Running Outlet
Outlet at centreGUTTER LAID GUTTER LAID TOLEVEL FALL 1/600
L/S Area L/S Area3.51 168 4.21 202
Area= M2
L/S= Litres per second
Carrying CapacityOutlet at one end GUTTER LAID GUTTER LAID TOLEVEL FALL 1/600
L/S Area L/S Area 1.83 87 2.21 106
6395 MFP Rainwater single pgs 12/11/2004 14:42 Page 9
Industrial 150mm
10
Gutter Running Outlet
Internal StopendUnion Clip
Fascia Bracket External Stopend
Gutter Angle 90˚
RGW 4 4 Metres ROW 1
110mm Circular Spigot
RUW 1 REW 1
RKW 1 REW 2
RAW 1
ColoursBlackGrey
Downpipe size110mm Circular
Installation Method see Page 18
150mm x 75mm
150mm Industrialrainwater system isdesigned to meet therequirements of largecommercial andindustrial installations.Capable of carryingup to 5.80 litres asecond, Industrial isideal for all large roofareas.
Manufactured toBS 4576:PART 1:1989BS EN 607:1996
150
75
Code
Code Code
Code Code
Code Length
Code
Outlet at centreGUTTER LAID GUTTER LAID TOLEVEL FALL 1/600
L/S Area L/S Area4.83 231 5.80 278
Area= M2
L/S= Litres per second
Carrying CapacityOutlet at one end GUTTER LAID GUTTER LAID TOLEVEL FALL 1/600
L/S Area L/S Area 2.41 115 2.89 138
6395 MFP Rainwater single pgs 12/11/2004 14:43 Page 10
Miniline 75mm
11
Gutter
Union Clip
Spare Clip
Fascia Bracket
RMG2 2 Metres RM01
RMU1
RMC1
RMK1
ColoursGreyChestnut brown
Pipe size51mm Circular
Installation Method see Page 19
75mm x 33mm
Miniline is speciallydesigned toefficiently drainsmaller roof areassuch as porches,greenhouses andsheds.
Manufactured toBS EN 607:1996
Running Outlet
75
33
Offset Bend Pipe Clip
Gutter Angle
RNS1 RCS1
RMA190°
Internal / External Stopend
RME1 RME2
51mm Pipe
RPS2 2 Metres
Shoe
RSN2
Code Length Code
Code Code
RMA245°
Code
Code
Code LengthCode
Code CodeCode Code
Code
Carrying CapacityOutlet at one end GUTTER LAID GUTTER LAID TOLEVEL FALL 1/600
L/S Area L/S Area 0.33 16 0.40 19
Outlet at centreGUTTER LAID GUTTER LAID TOLEVEL FALL 1/600
L/S Area L/S Area0.54 26 0.64 31
Area= M2
L/S= Litres per second
6395 MFP Rainwater single pgs 12/11/2004 14:43 Page 11
Offset Bend 67.5°
Shoe
Bends
RS 25
RB 251 87.5˚RB 252 67.5˚RB 253 45˚
68mm Circular Downpipe
12
Pipe
Swanneck Spigot / Socket 67.5˚
Loose Pipe Socket
Socket Clip
Pipe Clip
RPH 252 2 MetresRPH 2525 2.5 MetresRPH 253 3 MetresRPH 2555 5.5 Metres
RNE 255RL 25
RC 251
RCZ 253
ColoursBlackGreyWhiteBrown
Installation Method see Page 20
Suitable for usewith the followingGutter Systems:100mm Half-Round125mm Half-RoundClipmasterDeepflowFlowlineClassic
68
Pipe Plain
RPH 6804 4 Metres
Code Length
Barrel Clip
RC 252
Code
Code Length Code Code
Code Code
Code Code
Code
Code
RNE 251 RNE 250
6395 MFP Rainwater single pgs 12/11/2004 14:43 Page 12
13
Offset Bend 67.5˚
Offset Socket / Spigot 20˚
Reducers 110 x 68mm
Leaf Guard
Rainwater Adaptor
Balcony Outlet Flat Roof Outlet
Ring Seal Pipe Socket
RNA 250
RNE 252 RNE 253
For deep fascia
RV 225
RRM 425
MKRAB
ROB 25 ROF 25
RLR 25
Solvent weld to cut pipeBranch 67.5°
RY 252
Hopper Head
RH 252
155mm 286mm
230mm
Code
68mm Circular Downpipe contd.
Code Code
Code Code
Code Code
Code Code
Code Code
68mm
6395 MFP Rainwater single pgs 12/11/2004 14:43 Page 13
81mm Circular Downpipe
14
Pipe Bends
BranchLoose Pipe Socket
Socket Clip Shoe
Swanneck Spigot / Socket 67.5˚
Hopper Head
RPH 302 2 MetresRPH 3025 2.5 MetresRPH 303 3 MetresRPH 3055 5.5 Metres
SB 31 87.5°SB 35 45°
Adjustable 64˚ to 87.5˚
RL 30 SY 33
RC 301 RS 30
SH 30
SRM 304
ColoursBlack
Installation Method see Page 20
Suitable for usewith the followingGutter Systems:125mm Half Round
81
RNE 301 RNE 300
110mm x 82.4 mm
155mm280mm
230mm
Reducer
Code Length
Code
Code Code
Code
Barrel Clip
RC 302
Code
Code
Code Code
Code
Code
6395 MFP Rainwater single pgs 12/11/2004 14:43 Page 14
110mm Circular Downpipe
15
Pipe Bends
Offset Socket / Spigot 45˚Loose Pipe Socket
Socket Pipe Clip Collar Branch 87.5°
Barrel Pipe Clip Shoe
Hopper HeadAdaptor
SP 403 3 MetresSP 404 4 Metres
SB 41 87.5˚SB 45 45˚
SE 400 SNE 450 SNE 451
SC 41 SC 621 SY 400
SC 45 SS 41
SA 44 SH 40
ColoursBlackGrey
Installation Method see Page 20
Suitable for usewith the followingGutter Systems:150mm Industrial
110
For cast iron flat roof outlet
Code Length
Code
Code Code
Code
Code Code
Code
Code
Code Code
Code
6395 MFP Rainwater single pgs 12/11/2004 14:43 Page 15
65mm Square Downpipe
16
Pipe Offset 54mm Projection
Pipe Socket
One Piece Clip
Branch 67.5°
Two Piece Clip Outlet Adaptor / Drain Adaptor
Hopper Head
RPE 25 2.5 MetresRPE 3 3 MetresRPE55 5.5 Metres
RLE 1 RLE 11
RNE 1
RCE 1
RYE 1
RCE 2 RLE 3 RLE 2
RH 252
ColoursBlackWhiteChestnut brown
Installation Method see Page 22
Suitable for usewith the followingGutter Systems:FlowlineClassic
Shoe
RSE 1
65
65
Eaves Offset Bends
RBE 167.5˚
RBE 390˚
155mm 280mm
230mm
Code Length
Code
Code Code Code
Code Code
Code Code Code
Code Code Code
6395 MFP Rainwater single pgs 12/11/2004 14:43 Page 16
Universal Fittings
17
Extension backplate Rise & fall Extension Arm
Universal Gutter Notching ToolDrive-in Spike
Angled Fascia Bracket Adaptor
Solvent Cement
Rafter Arm
Lubricant
RT 200 RKF 1
RSS 1 RGN 1
RKA 1 22.5˚RKA 2 30˚
KS2 55ml tubeKS10 250ml Can with brush
RSA 1 SideRTA 1 Top
110mm
173mm
290mm
100mm
225mm
Code Code
Code Code
Code
Code
Code
LUB 800
Code
Fascia Bracket Adaptor
RGS 1
Code
Rainwater Adaptor
MKRAB
Code
6395 MFP Rainwater single pgs 12/11/2004 14:43 Page 17
18
The notch technique of jointinghalf-round gutters has been usedsuccessfully for many years andis well proven. The 100mm and125mm half-round systemsboth have an integral socketmoulded on one end of eachlength of gutter. A flexible PVCustrap is employed to compressthe spigot on to the syntheticrubber seal, which is factorysecured to the socket. (Fig. 1)The Deepflow and Industrialsystems are also notched butthey are assembled usingspecial integrally-mouldedretaining nibs on all fittingswhich, together with the factory-fitted synthetic rubber seals,make site-assembly simple andensures a watertight joint. (Fig. 2)
Thermal MovementThe notch technique, when correctlyexecuted as indicated, ensures thatthe system cannot pull apart but stillprovides for expansion andcontraction resulting from changesin temperature and climaticconditions.
Stop End
Retaining nibs
Gutter union
Gutter strap
Fig. 1
Fig. 2
Installation Instructions
Installation(100mm half-round)
Notched Gutter Systems
Fascia BracketsBrackets are secured to the fasciaboard with two 25 x 5mmsheradized round headed screws.Spacing of the brackets shouldnever exceed 1 metre centres.
Brackets which have an option forsingle screw fixing should besecured by using a 32 x 5mm non-corrosive screw.
In areas subjected to heavy snowfalls, closer bracket spacing isrequired and it is recommended thateach bracket is secured with aminimum of two 25mm screws.
Angles and OutletsAll internal and external angles andoutlets should have closesupporting brackets not exceeding150mm on each side.
Union and StopendsAll union and stopends should havea close supporting bracket notexceeding 150mm on one side.
Gutter socket
Gutter spigot
Flexible seal
Running Outlet
Stopend Outlet
Pipe ClipOffset Bend
90° Angle
150mm
Shoe
150mm
1 M Max
Fascia Brackets
6395 MFP Rainwater single pgs 12/11/2004 14:43 Page 18
19
The Flowline, Classic,Clipmaster and Minilinesystems are plain ended guttersand are jointed to the fittingssimply by engaging one edge ofthe gutter under the factory-fitted clip on the fitting andexerting downward pressure onthe other edge, therebycompressing the gutter againstthe seal to form a watertightjoint. An insertion depth isclearly marked on each fittingand the gutter end should notproject beyond this point.
Fit Gutter up to insertion depth
Thermal MovementCertain key fittings incorporatescrew fixing points on the back edgeand must be screwed to the fascia.When installed in this way, the jointcannot pull apart and will absorb theexpansion and contraction resultingfrom variations in temperature.
Stop ends must be fitted only toshort lengths of gutter, i.e. within300mm of an adjacent fitting.
Fascia BracketBrackets are secured to the fasciaboard with two 25 x 5mm sheradizedround headed screws. Spacing ofthe brackets should never exceed 1metre centres.
Brackets which have an option forsingle screw fixing should besecured by using a 32 x 5mm non-corrosive screw.
In areas subjected to heavysnowfalls, closed bracket spacing isrequired and it is recommended thateach bracket is secured with aminimum of two 25mm screws.
Classic gutter is normally fitted leveland offers a choice of eitherconventional external fasciabrackets or top hung internalbrackets which, because they areconcealed, give an uninterruptedline to the ogee gutter.
Angles and OutletsAll internal and external angles andoutlets should have close supportingbrackets at a distance not exceeding150mm on each side.
Unions and StopendsClassic unions and all stopendsshould have a close supportingbracket at a distance not exceeding150mm on one side.
Flowline and Clipmaster unionsfeature integral brackets, thereforeclose supporting brackets are notrequired. Flowline and Classicoutlets are available to suit both68mm circular and 65mm squaredownpipe systems.
Clipmaster outlets are available tosuit 68mm circular pipework only butaccept both plain-ended or socketedpipe.
Right handstopend
Square rainwater pipe
90° angle
300mm Max
150mm
150mm
150mm
1 M
Union
Internal fasciabracket
Union
Gutter ClipJointing
Installation(Classic)
Running outlet
Installation InstructionsPlain Ended Gutter System
6395 MFP Rainwater single pgs 12/11/2004 14:43 Page 19
1.8 M Max
FIXING CLIP
FIXING CLIP
FIXING CLIP
FIXING CLIP
FIXING CLIP
20
Rainwater pipes are generally fittedexternally with joints between spigotand socket left unsealed. 68mmcircular rainwater pipe is suitable foruse with 100mm and 125mm HalfRound, Clipmaster, Deepflow,Flowline and Classic systems.81mm circular rainwater pipe issuitable for use with 125mm HalfRound system. 65mm square pipe ismainly used with Flowline andClassic systems. It may be installedwith 100mm and 125mm HalfRound, Clipmaster and Deepflowsystems by using the RLE3 adaptor.
The 110mm Circular rainwater pipeis designed for the Industrial Guttersystem.
The 51mm Circular rainwater pipe isused in conjunction with the 75mmMiniline system.
Every rainwater pipe should have aclip located at its socket to supportthe pipework system. Intermediatepipe clips should then be providedat maximum 1.8m centres. Anexpansion gap of 10mm should beallowed between the end of eachpipe and the bottom of the socket.
N.B. Ensure grid is inposition beforeknocking out
Rainwater68mm or 81mm
Drainage 110mm
Grid UGG 1Gully Grid with
removable section to suitsquare rainwater pipe.
CLIP
UNIVERSALGULLY UG 410
65mm SquareRainwater pipedischarging below gully grating
Connection to below ground drainageExternal rainwater pipes may either connectdirectly to a drain or via a gully trap
Circular or square PVCuRainwater Shoedischarging over gully grid.
Back inlet con-nection to gullywith top raised.
68mm, 81mm or 110mmCircular pipe
Gully UG 411/3Remove with pad saw
Installation InstructionsRainwater Pipes
Side Inlet ConnectionsThe Universal gully has 3 boss upstandson each side to suit waste, rainwater anddrainage connections. The knock-outcentres of these upstands are easilyremoved by tapping out the fourpressure points, whilst ensuring grid isin position.
6395 MFP Rainwater single pgs 12/11/2004 14:43 Page 20
Notes