Transcript

3

A

B

C

D

E

F

G

H

J

K

1

2

6

7

8

11

151617181920212223 14 13 12

9

10

3

5

4

1X100319.32 m²

Team Entrepreneurship/ B01

1X10285.12 m²

Team Entrepreneurship/ B03

1XC10132.04 m²

Corridor/ B02A

1XS00F22.78 m²

Stair-Core F/ B04A

1XL00D6.38 m²

Lift EV-Core C/ B04C

1XL00C7.26 m²

Lift/ B04B

1X11338.50 m²

Water Tank/ B17

1X11521.93 m²

Substation/ B15

1X1143.63 m²

Air inlet/ B16

1X1113.47 m²

Air exhaust/ B18

1X1103.89 m²

Gas intake/ B19

1X112324.57 m²

Plant Room/ B12

1X112A26.39 m²

Boiler Room/ B25

1X112D44.65 m²

LV Switchroom/ B21

1X112C3.98 m²

LV Intake/ B23

1X112B3.44 m²

District Heating Intake/ B22

??

?/ ?

1XV1024.09 m²

Void/ B32

1XC1036.28 m²

Lobby/ B30

1XC10031.93 m²

Corridor/ B02B

1X1045.47 m²

A-WC/ B09

1XD1033.58 m²

Elec Riser-Core C/ B08

1XS00E4.27 m²

Stairs Team Entrepreneurship/ B01A

1X102A8.74 m²

Comms-Core C/ B05

1XC1025.13 m²

Lobby/ B28

1XV1014.89 m²

Void/ B29

1XD10685.91 m²

Plant Room below seating/ B20

1XC10457.30 m²

Lecture Theatre Breakout/ B24

1 23

5

4

6

no

rt

h

zone plan

Notes on general arrangement plans:

• This drawing set is to indicate room, window, door etc. references andgeneral information.

• For all detail drawing references and sections refer to:

FCFBL-STL-B1-ZZ-DR-A-ZZ-12001

FCFBL-STL-GF-ZZ-DR-A-ZZ-12002

FCFBL-STL-01-ZZ-DR-A-ZZ-12003

FCFBL-STL-02-ZZ-DR-A-ZZ-12004

FCFBL-STL-03-ZZ-DR-A-ZZ-12005

FCFBL-STL-04-ZZ-DR-A-ZZ-12006

FCFBL-STL-05-ZZ-DR-A-ZZ-12007

FCFBL-STL-06-ZZ-DR-A-ZZ-12008

basement levelground Level

level-01

level-02level-03

level-04

level-05

roof level

room name description

• Room ID Tag description; example...

50p Teaching Exec Ed/ 4.108

116.57m²

6X109 contract room ID used for contract

information

UWE room ID using UWE naming

convention and Building title as

Building 'X'

Area of room in m²

PROJECT

DRAWING TITLE

SCALE

RE

VIS

ED

BY

CH

EC

KE

D B

Y

Responsibility is not accepted for errors made by others in scaling from this drawing.All construction information should be taken from figured dimensions only.

Stride Treglown

0mm 100mm50mm

© Stride Treglown Limited 2014

CLIENT NAME

SUITABILITY STATUS

http://www.stridetreglown.com/en/contact/bristol.html Bristolhttp://www.stridetreglown.com/en/contact/bristol.html

stridetreglown.com

ORIGINATOR NO

@ A0

PROJECT REVISIONORIGINATOR ZONE LEVEL TYPE ROLE CLASSIFICATION NUMBER

www.stridetreglown.com

M A N N W I L L I A M S

BATH OFFICE

CONSULTING CIVIL ANDSTRUCTURAL ENGINEERS

T: 01225 464419

W: www.mannwilliams.co.uk

140 Aztec West

Business Park

Bristol

BS32 4TX

01454 201 020

www.hoarelea.com

DESIGN TEAM

Refer to Conject 1 : 100

Faculty of Business and LawFrenchay Campus

Coldharbour Lane

Bristol

BS16 1QY

GA Furniture Plan- Basement

Au

tho

r

Ch

ecke

r

University of the West of England 32147

FCFBL-STL-00-B1-DR-A-ZZ-10501-P50

REV DATE DESCRIPTION STATUS

P17 22-MAY-15 Pop Up setting out Information S2

P34 22-DEC-15 Issued to the Client for Review S3

P35 23-DEC-15 Issued with M + E Information for Coordination S3

P36 08-DEC-15 Issued to the Client for Review of furniture and printerlocations

S3

P37 15-JAN-16 Issued for M+E Review S3

P42 26-JAN-16 Issued to the Client for Review incorporating comments

Issued to the Client for Review incorporating comments

S3

P43 03-FEB-16 Issued to Client for Review S3

P44 15-FEB-16 Issued for Review S3

P46 23-FEB-16 Issued for Review S3

P47 29-FEB-16 Issued for Tender S3

P48 01-MAR-16 Issued for Tender S3

P50 23-MAR-16 Issued for Tender with TE Furniture included S3

M 1 : 100

Lower Ground Floor Furniture Plan

32446