Transcript
Page 1: 3 T METROLOGY MAGNET · 2017-03-15 · 3 T METROLOGY MAGNET. APPLICATIONS •Magnetic field probe calibration. •Hall-effect studies •NMR/NMRD •ESR •FMR •Transport studies

• Variablefield+3T

• Highuniformityoverthewholeexcitationrange

• Large25mmpolegap

• Compact

Lowfringemagneticfield

• CryogenFree

3 T METROLOGY MAGNET

APPLICATIONS

• Magneticfieldprobecalibration.

• Hall-effectstudies

• NMR/NMRD

• ESR

• FMR

• Transportstudies

PERFORMANCE

• 3Tvariablefield

• Betterthan50ppmfielduniformity(10mmDSV)acrosstheexcitationrange

• SuitableforNMRteslameter

• Largefixedpolegap(25mm)

• Largesampleaccessslot:25x150mm

• Optionalhighstabilityunipolarpowersupply

• Optionalelectricshims[Z,Y,Z,Z2]tofurtherincreaseuniformity(<1ppmover10mmDSV)

EASY TO USE

• Cryogen-freeoperation:nohandlingofliquidheliumornitrogen

• Magnetsafetymonitoringelectronicsincluded

• Reliablemechanicalcooling(<4kWinputpower)

• Lowwatercoolingrequirements,optionalchiller

EASY TO SITE

• Compactsize

• Verylowfringefield,maybereducedfurtherwithoptionalenclosure

• Compressorcanbesited

r emotely(up to 10 mm)

• Verticalorhorizontalaccessslotorientation

Page 2: 3 T METROLOGY MAGNET · 2017-03-15 · 3 T METROLOGY MAGNET. APPLICATIONS •Magnetic field probe calibration. •Hall-effect studies •NMR/NMRD •ESR •FMR •Transport studies

3 T METROLOGY MAGNET

hts-110.com

HTS-1101B Quadrant DriveWaiwhetuLower HuttNew Zealand

t +64 4 570 8880 e [email protected]

LinkedIn:nz.linkedin.com/company/hts-110

DistributedinNorthAmericabyGMWAssociates955IndustrialRoadSanCarlos,CA94070,USA

t +6508028292wgmw.com

SYSTEM SPECIFICATIONS:

• 3Tfullfieldat180A.

• Betterthan50ppmuniformity(10mmDSVacrosstheexcitationrange(<1ppmwithRTshims).

• Systemcooldown(roomtemperaturetooperatingtemperature):<30h(60Hz).

• Sampleaccess:25x150mm.

• Fringefield:5gausslineat<1.6m(axial)and1.3m(radial)frommagnetcentre.

• Magnetmass:200kg.

• Systemmasswithbipolarpowersupply,cryocoolerandcompressor:450kg.

STANDARD SYSTEM INCLUDES:

• Magnetsub-systemwithintegratedcold-head.

• 19”rack-mountedcompressorandpowersupply.

• Activemagnetprotectionelectronicslinkedtointegratedtemperaturesensorsandvoltagetaps.

• Magnetenergydumpsystem.

• Bipolarpowersupplyoroptionalhighstability.

(0.3ppm/h)unipolarsupply.

• 1yearwarranty.

SYSTEM OPTIONS:

• Fieldcontrolsystem.

• Electricalshimmingforimprovedfieldhomogeneity(X,Y,Z,Z2).

• Lowmaintenancevacuumpump.

• Magnetenclosureforreducedfringefield.

• Waterchiller.

• Extendedwarranty.

• RTshimset.

SITE REQUIREMENTS:

• <6litreswaterperminuteforcompressor

• 50/60Hz,~4kW.

• Scheduledmaintenanceoncold-headevery13,000h,compressor30,000h.

• Vacuumpumpforinitialinstallationandmaintenance;turbomolecularpumprecommendedwithminimumpumpingspeed30l/sandultimatepressure<1E–7mbar.

• Variable Field Relaxometry (NMRD NuclearMagnetic Relaxation Dispersion)

• Developed in association with Stelar (Italy)

• Used for example in characterisation of newMRI contrast agents optimised for newhigher-field MRI systems

APPLICATION EXAMPLE: