Energy Efficiency
in Industrial Heating
Systems
וולקאן גרדאן Volkan GERDAN
Mechanical Engineer
Energy Manager (Buildings and Industry)
![Page 2: הרצאת וולקן גרדן - לדיקו גרין](https://reader034.vdocuments.mx/reader034/viewer/2022042813/54579bb3af795912668b5504/html5/thumbnails/2.jpg)
An Indian Proverb
Only when the last tree is cut.
Only when the last river is polluted.
Only when the last fish is caught.
Only then will they realize that
you cannot eat money.
![Page 3: הרצאת וולקן גרדן - לדיקו גרין](https://reader034.vdocuments.mx/reader034/viewer/2022042813/54579bb3af795912668b5504/html5/thumbnails/3.jpg)
Energy Efficiency
• Energy Efficiency – Energy Saving
• Two phrases that are most confusing.
• Energy Saving
is reduction of energy consumption
with one or multiple measures,
resulting in foreseen reduction or change in
quality, quantity, comfort, safety etc.
• Energy Efficiency
is reduction of energy consumption
while producing the same quantity
in the same quality.
(…or more in higher quantity)
![Page 4: הרצאת וולקן גרדן - לדיקו גרין](https://reader034.vdocuments.mx/reader034/viewer/2022042813/54579bb3af795912668b5504/html5/thumbnails/4.jpg)
First Step into Energy Efficiency
10 - 5 - 2 - 1 - 0.5 - 0.1 %
What is more important?
Leaking
DroppingTap Visible!
Leaking
DroppingEnergy Invisible!
![Page 5: הרצאת וולקן גרדן - לדיקו גרין](https://reader034.vdocuments.mx/reader034/viewer/2022042813/54579bb3af795912668b5504/html5/thumbnails/5.jpg)
First Step into Energy Efficiency
![Page 6: הרצאת וולקן גרדן - לדיקו גרין](https://reader034.vdocuments.mx/reader034/viewer/2022042813/54579bb3af795912668b5504/html5/thumbnails/6.jpg)
First Step into Energy Efficiency
![Page 7: הרצאת וולקן גרדן - לדיקו גרין](https://reader034.vdocuments.mx/reader034/viewer/2022042813/54579bb3af795912668b5504/html5/thumbnails/7.jpg)
Energy in the Industry
• Energy is used in two major forms in the industry:
• Electricity
• Heat
• Many of the electricity consuming processes
are heat sources by themselves.
• A good portion of electricity consumption is
caused by heat production or distribution.
So there’s no possibility of a real reduction of energy intensity
without taking both into consideration.
![Page 8: הרצאת וולקן גרדן - לדיקו גרין](https://reader034.vdocuments.mx/reader034/viewer/2022042813/54579bb3af795912668b5504/html5/thumbnails/8.jpg)
• Energy intensity
• It’s basically the ratio of energy consumption with production.
• Calculated as TOE of energy consumed per 1,000 USD sales revenues.
• As example: Energy intensity of several countries
Energy in the Industry
e
OECD 0.17
North America 0.20
Europe 0.14
Asia 0.17
EU27 0.12
Germany 0.11
UK 0.09
Japan 0.09
Switzerland 0.06
Israel 0.14
![Page 9: הרצאת וולקן גרדן - לדיקו גרין](https://reader034.vdocuments.mx/reader034/viewer/2022042813/54579bb3af795912668b5504/html5/thumbnails/9.jpg)
Energy in the Industry
• Efficiency Increasing Projects (EIPs)
4Ro Reduceo Reuseo Recycleo Rethink
![Page 10: הרצאת וולקן גרדן - לדיקו גרין](https://reader034.vdocuments.mx/reader034/viewer/2022042813/54579bb3af795912668b5504/html5/thumbnails/10.jpg)
Energy in the Industry
• Efficiency Increasing Projects (EIPs)
Optimization Projects:
With no or limited investment costs
easily applicable by the industrial facility itself.
Example:
Temperature setting in an office:
1°C means 10%
![Page 11: הרצאת וולקן גרדן - לדיקו גרין](https://reader034.vdocuments.mx/reader034/viewer/2022042813/54579bb3af795912668b5504/html5/thumbnails/11.jpg)
Energy in the Industry
• Efficiency Increasing Projects (EIPs)
Improvement Projects:
With low investment costs
implemented on the existing process.
Example:
Heat insulation of the existing
pipes:
Payback times less than half a
year are possible.
![Page 12: הרצאת וולקן גרדן - לדיקו גרין](https://reader034.vdocuments.mx/reader034/viewer/2022042813/54579bb3af795912668b5504/html5/thumbnails/12.jpg)
Energy in the Industry
• Efficiency Increasing Projects (EIPs)
Upgrading Projects:
With varying investment costs
resulting in higher, sustainable energy efficiency changes.
Example:
Economizer integration to an
existing steam boiler:
5% or more saving can
be achieved without
further costs.
![Page 13: הרצאת וולקן גרדן - לדיקו גרין](https://reader034.vdocuments.mx/reader034/viewer/2022042813/54579bb3af795912668b5504/html5/thumbnails/13.jpg)
Efficiency Increasing Projects
• Heat Recovery
• It’s one of the most applicable methods of energy efficiency increase.
• Anything carrying excess heat is the source disregarding its
temperature:
• Discharged hot water from any process heater
• Ovens (heat-recovery from multiple points possible)
• Condensate return of the steam system
• Boiler’s flue gases
![Page 14: הרצאת וולקן גרדן - לדיקו גרין](https://reader034.vdocuments.mx/reader034/viewer/2022042813/54579bb3af795912668b5504/html5/thumbnails/14.jpg)
Efficiency Increasing Projects
• Economizers
![Page 15: הרצאת וולקן גרדן - לדיקו גרין](https://reader034.vdocuments.mx/reader034/viewer/2022042813/54579bb3af795912668b5504/html5/thumbnails/15.jpg)
Efficiency Increasing Projects
• Economizers
• Fuel savings 5% or more
• Pre-heating of the boiler’s feedwater
• Pre-heating of any other circuit is possible
Steam
at 10 bar
184°C
Economiser with
integrated by-pass
Chimney
Flue-gas
temperature
>200°C
Heavy Oil
~160°C
Gas
~120°C
![Page 16: הרצאת וולקן גרדן - לדיקו גרין](https://reader034.vdocuments.mx/reader034/viewer/2022042813/54579bb3af795912668b5504/html5/thumbnails/16.jpg)
Efficiency Increasing Projects
• Economizers
• Stand alone versions allow
• Implementation to any steam boiler
• Gas, light oil or heavy oil
![Page 17: הרצאת וולקן גרדן - לדיקו גרין](https://reader034.vdocuments.mx/reader034/viewer/2022042813/54579bb3af795912668b5504/html5/thumbnails/17.jpg)
Efficiency Increasing Projects
• Ovens and Drying
• Optimization project: Change of temperature setting (Rethink!)
• Heat-recovery options:
• Air recirculation
15 – 40% efficiency increase
• Air pre-heating
15 – 25% efficiency increase
![Page 18: הרצאת וולקן גרדן - לדיקו גרין](https://reader034.vdocuments.mx/reader034/viewer/2022042813/54579bb3af795912668b5504/html5/thumbnails/18.jpg)
Air
EconomizerExhaust
Fresh-Air
from
CHP Plant
from
Flash
steam
from
Steam
Boiler
Efficiency Increasing Projects
• Case Study: Paper Mill
Implementation of heat recovery system to an existing paper mill:
24% increase of energy efficiency
50% increase of production without increase of energy consumption
Investment amount: Annual Savings: Payback Period
220,000 EUR 7,806,000 kWh – 200,000 EUR Less than 1.5 years
Paper Mill:
2.0 t/day of 300 g/m2 paper increased to 3.1 t/day
810 kW out of 3,370 kW recovered !!!
![Page 19: הרצאת וולקן גרדן - לדיקו גרין](https://reader034.vdocuments.mx/reader034/viewer/2022042813/54579bb3af795912668b5504/html5/thumbnails/19.jpg)
Efficiency Increasing Projects
• Using the “high” calorific value of the fuel
via condensation technology
Condensing Boiler
Vapor
High
Calorific
Value
Low Calorific Value
Condensation
Heating
System
Used Heat
![Page 20: הרצאת וולקן גרדן - לדיקו גרין](https://reader034.vdocuments.mx/reader034/viewer/2022042813/54579bb3af795912668b5504/html5/thumbnails/20.jpg)
Efficiency Increasing Projects
What is
Condensation
Technology?
![Page 21: הרצאת וולקן גרדן - לדיקו גרין](https://reader034.vdocuments.mx/reader034/viewer/2022042813/54579bb3af795912668b5504/html5/thumbnails/21.jpg)
Efficiency Increasing Projects
Heating
Energy
+ CO2 + H20
FuelNatural gas, Fuel-oil,
Diesel-oil etc.
(C,H,O …)
Air (O2) Losses
• Summary of Heating
![Page 22: הרצאת וולקן גרדן - לדיקו גרין](https://reader034.vdocuments.mx/reader034/viewer/2022042813/54579bb3af795912668b5504/html5/thumbnails/22.jpg)
Efficiency Increasing Projects
Chimney Heat Losses
Losses of Energy Due To
The Latent Heat In Water
Vapor
Very Low Flue Gas
Temperatures
Condensation
• Heat Losses and Recoveries
![Page 23: הרצאת וולקן גרדן - לדיקו גרין](https://reader034.vdocuments.mx/reader034/viewer/2022042813/54579bb3af795912668b5504/html5/thumbnails/23.jpg)
Efficiency Increasing Projects
• Is 110% efficiency possible?
km/hmiles/h
100 miles/h > 100 km/h
![Page 24: הרצאת וולקן גרדן - לדיקו גרין](https://reader034.vdocuments.mx/reader034/viewer/2022042813/54579bb3af795912668b5504/html5/thumbnails/24.jpg)
Efficiency Increasing Projects
Lower Heating Value Hs
The latent heat in water vapor is not
taken into consideration and the rest
is accepted to be 100%.
Higher Heating Value Hi
The latent heat in water vapor is
taken into account and the total is
accepted to be 100%.
For natural gas:
8.250 kcal/m3 9.155 kcal/m3
100 units of energy 111 units of energy
• Is 110% efficiency possible?
![Page 25: הרצאת וולקן גרדן - לדיקו גרין](https://reader034.vdocuments.mx/reader034/viewer/2022042813/54579bb3af795912668b5504/html5/thumbnails/25.jpg)
Efficiency Increasing Projects
Total Heat Recovery of Condensing Boiler: 5 – 17%
Chimney Heat Losses
LT Boiler 6 – 9%
Condensing Boiler 1 – 2%
Heat Recovery 5 – 7%
Condensation
LT Boiler 0%
Condensing Boiler 0 – 10%
Heat Recovery 0 – 10%
• Is 110% efficiency possible?
![Page 26: הרצאת וולקן גרדן - לדיקו גרין](https://reader034.vdocuments.mx/reader034/viewer/2022042813/54579bb3af795912668b5504/html5/thumbnails/26.jpg)
Efficiency Increasing Projects
• Condensing boilers
![Page 27: הרצאת וולקן גרדן - לדיקו גרין](https://reader034.vdocuments.mx/reader034/viewer/2022042813/54579bb3af795912668b5504/html5/thumbnails/27.jpg)
Efficiency Increasing Projects
• Condensing boilers
![Page 28: הרצאת וולקן גרדן - לדיקו גרין](https://reader034.vdocuments.mx/reader034/viewer/2022042813/54579bb3af795912668b5504/html5/thumbnails/28.jpg)
Efficiency Increasing Projects
• Losses of a boiler
• Chimney losses
• Cooling losses
• Chimney losses occur only when the burner is running.
• Cooling losses occur
• Stand-by losses:
During stand-by on a fixed temperature
(when the burner is off)
• Radiation losses:
During the operation
(when the burner is running)
![Page 29: הרצאת וולקן גרדן - לדיקו גרין](https://reader034.vdocuments.mx/reader034/viewer/2022042813/54579bb3af795912668b5504/html5/thumbnails/29.jpg)
Efficiency Increasing Projects
• Radiation losses are relative to
• Dimensions
• Water volume
• Weight
Stand-by and
radiation losses Chimney losses
Fuel losses
![Page 30: הרצאת וולקן גרדן - לדיקו גרין](https://reader034.vdocuments.mx/reader034/viewer/2022042813/54579bb3af795912668b5504/html5/thumbnails/30.jpg)
Efficiency Increasing Projects
• The cooling losses are the sum of radiation and stand-by losses.
Burner running : Radiation losses 1,2%
Burner off : Stand-by losses 0,8%
Total cooling losses are
2% in average.
• During the operation of the burner, combustion and chimney losses are
happening.
Chimney losses : 7%
Combustion losses : 7%
![Page 31: הרצאת וולקן גרדן - לדיקו גרין](https://reader034.vdocuments.mx/reader034/viewer/2022042813/54579bb3af795912668b5504/html5/thumbnails/31.jpg)
Efficiency Increasing Projects
• Stand-by losses are depending on stand-by duration
• No stand-by means
• No stand-by losses.
• They are less than chimney losses.
Stand-by losses are in positive relation with boiler outshell area per kW
power
Higher boiler power has relatively less area.
• The ratio between chimney and stand-by losses:
in 70 kW 1:3
in 1000 kW 1:5
![Page 32: הרצאת וולקן גרדן - לדיקו גרין](https://reader034.vdocuments.mx/reader034/viewer/2022042813/54579bb3af795912668b5504/html5/thumbnails/32.jpg)
Efficiency Increasing Projects
• Combustion can affect both chimney and stand-by losses.
• In best way, the combustion is realized without any interruptions while
changing the capacity: Modulation
On – Off Operation Operation with modulation
![Page 33: הרצאת וולקן גרדן - לדיקו גרין](https://reader034.vdocuments.mx/reader034/viewer/2022042813/54579bb3af795912668b5504/html5/thumbnails/33.jpg)
Efficiency Increasing Projects
• Capacity modulation
• Boilers and burners are selected for the peak load.
• Normally they are running on lower capacities.
• In case of an on/off controlled burner, partial loads cause
very high cycling frequency!
![Page 34: הרצאת וולקן גרדן - לדיקו גרין](https://reader034.vdocuments.mx/reader034/viewer/2022042813/54579bb3af795912668b5504/html5/thumbnails/34.jpg)
Efficiency Increasing Projects
• Every cycling (on/off) causes
Reduction of burner economic life
A swap away period of the fan
Air sent to the chimney together with the rest heat
A period of bad combustion conditions
(with very low efficiency)
Loss of unused fuel
Stand-by (cooling) losses
• Annual losses via cycling
On-off burners: ~ 5%
Modulating burners: ~ 1%
![Page 35: הרצאת וולקן גרדן - לדיקו גרין](https://reader034.vdocuments.mx/reader034/viewer/2022042813/54579bb3af795912668b5504/html5/thumbnails/35.jpg)
Boilers with jet burners
Burner’s blower and chimney run as two fans in serial
connection.
Combustion air is under effect of ambient conditions.
Chimney draught (Pa) = h x (r1-r2)
h = Height of the chimney (m)
r1= Density of outdoor air (kg/m3)
r2= Density of flue-gas (kg/m3)
Efficiency Increasing Projects
• How to control the combustion?
![Page 36: הרצאת וולקן גרדן - לדיקו גרין](https://reader034.vdocuments.mx/reader034/viewer/2022042813/54579bb3af795912668b5504/html5/thumbnails/36.jpg)
• How to control the combustion?
Efficiency Increasing Projects
Start-Up /
Maintenance Day
To= 20oC
Colder Day
To = 5°C
Warmer Day
To = 30°C
Higher draught and
Higher air surplus
Low Efficiency
Lower draught and
Lower air surplus
Low Efficiency and Soot
![Page 37: הרצאת וולקן גרדן - לדיקו גרין](https://reader034.vdocuments.mx/reader034/viewer/2022042813/54579bb3af795912668b5504/html5/thumbnails/37.jpg)
Efficiency Increasing Projects
• Choosing the right burner is an energy increasing project!
• One staged burners
• Two staged burners
• Modulating burners
• Modulating burners
with pneumatic mixing (soot-free burners)
• Larger capacities:
• Frequency controlled (> 2,000 kW)
• Oxygen controlled (> 3,000 kW)
![Page 38: הרצאת וולקן גרדן - לדיקו גרין](https://reader034.vdocuments.mx/reader034/viewer/2022042813/54579bb3af795912668b5504/html5/thumbnails/38.jpg)
Efficiency Increasing Projects
• Combined Heat and Power Generation
• Cannot be understood in the scope of energy efficiency.
• On the other hand it’s an important method of cost reduction.
• CHP basically allows to switch
from one energy source
to another.
• Important primary energy savings
and reduction of CO2 emissions
are generated
![Page 39: הרצאת וולקן גרדן - לדיקו גרין](https://reader034.vdocuments.mx/reader034/viewer/2022042813/54579bb3af795912668b5504/html5/thumbnails/39.jpg)
Efficiency Increasing Projects
• Combined Heat and Power Generation
• Is a CHP system applicable in my industrial facility?
• If a facility needs
• Heat
• Electricity
then the answer is “YES”.
For CHP, heat is always the prior demand.
![Page 40: הרצאת וולקן גרדן - לדיקו גרין](https://reader034.vdocuments.mx/reader034/viewer/2022042813/54579bb3af795912668b5504/html5/thumbnails/40.jpg)
Efficiency Increasing Projects
• Combined Heat and Power Generation
Fuel
100%
Thermal
Losses
68%
Electricity
32%
Fuel
100%
Thermal & Mechanical
Losses
20%
CHP Plant
Electricity
Steam
Hot water
Hot air
Chilled water
Useful
80%
![Page 41: הרצאת וולקן גרדן - לדיקו גרין](https://reader034.vdocuments.mx/reader034/viewer/2022042813/54579bb3af795912668b5504/html5/thumbnails/41.jpg)
Efficiency Increasing Projects
• Case Study: Plaster Factory
• Implementation of CHP’s heat recovery system to the existing tunnel
ovens as hot-air
• Feed-in of excess electricity
Investment amount: Annual Savings: Annual Income via Feed-In: Payback Period
910,000 EUR 180,000 EUR 240,000 EUR 2.2 years
Annual Primary Energy Savings: 1,480,000 kWh
Annual Reduction of CO2 Emissions: > 11,600 t eq
![Page 42: הרצאת וולקן גרדן - לדיקו גרין](https://reader034.vdocuments.mx/reader034/viewer/2022042813/54579bb3af795912668b5504/html5/thumbnails/42.jpg)
Other Topics of Energy Efficiency
• Compressed air systems: Up to 80% efficiency increase opportunities
• Implementation of renewable energy resources
• Thermal insulation
• Temperature settings
• Thermal storage
• Green buildings (factories)
• Recycling and waste management
• Energy monitoring (You cannot reduce if you cannot monitor!)
![Page 43: הרצאת וולקן גרדן - לדיקו גרין](https://reader034.vdocuments.mx/reader034/viewer/2022042813/54579bb3af795912668b5504/html5/thumbnails/43.jpg)