dotech sensing & control - · pdf filedotech sensing & control ... relay output :...
TRANSCRIPT
![Page 1: DOTECH SENSING & CONTROL - · PDF fileDOTECH SENSING & CONTROL ... Relay output : 4point, Temp. sensor input : 2 point DPR-TH1 : NTC 5k, ±0.3°C at 25°C(-50~105°C) FX32R Showcase](https://reader031.vdocuments.mx/reader031/viewer/2022021421/5ab587cd7f8b9ab47e8cf76c/html5/thumbnails/1.jpg)
DOTECHSENSING&CONTROL
SENSETE°C
H®
CW
CH
EAT-ED
GE®
RA
INB
OW
SHIM
AD
ENP
R ELEC
TRO
NIC
SKIM
OSEKO
NIC
HU
BA
KA
ISEO
HK
UR
AC
OR
DEX
FRIED
ELECTR
ICD
OTEC
H
![Page 2: DOTECH SENSING & CONTROL - · PDF fileDOTECH SENSING & CONTROL ... Relay output : 4point, Temp. sensor input : 2 point DPR-TH1 : NTC 5k, ±0.3°C at 25°C(-50~105°C) FX32R Showcase](https://reader031.vdocuments.mx/reader031/viewer/2022021421/5ab587cd7f8b9ab47e8cf76c/html5/thumbnails/2.jpg)
Product Index
DOTECH SENSING & CONTROL CATALOGUE
A. FX Series Digital Temperature Controller ................................................................................................................................................................................................................................................................................ Digital Humidity Controller ............................................................................................................................................................................................................................................................................................ Refrigeration Controller .................................................................................................................................................................................................................................................................................................... Multi-function Digital Controller .............................................................................................................................................................................................................................................................................. B. DX Series HVAC Controller ...................................................................................................................................................................................................................................................................................................................... Screw Compressor Controller ................................................................................................................................................................................................................................................................................... Multi Compressor Controller ....................................................................................................................................................................................................................................................................................... Geothermy Heat Pump Controller ........................................................................................................................................................................................................................................................................ Air-Source Heat Pump Controller .......................................................................................................................................................................................................................................................................... HTX Series Economical Module Type Temperature And Humidity Sensor ............................................................................................................................................................................................ OEM Temperature and Humidity Sensor ...................................................................................................................................................................................................................................................... Ultra-recise Indoor Type Temperature And Humidity Transmitter ....................................................................................................................................................................................... Analog Voltage Relative Humidity Module ..............................................................................................................................................................................................................................................
V-A1V-A2V-A3V-A5
V-B6V-B7V-B9V-B10V-B11
V-C12V-C12V-C13V-C13
SENSETE°C
H®
CW
CH
EAT-ED
GE®
RA
INB
OW
SHIM
AD
ENP
R ELEC
TRO
NIC
SKIM
OSEKO
NIC
HU
BA
KA
ISEO
HK
UR
AC
OR
DEX
FRIED
ELECTR
ICD
OTEC
H
Sensing Technology Corporation 457-B Boni Avenue New Zaniga Mandaluyong City Tel No. 532-0088 Fax No. 531-7387www.heatsenze.com [email protected]
SECTION V.
![Page 3: DOTECH SENSING & CONTROL - · PDF fileDOTECH SENSING & CONTROL ... Relay output : 4point, Temp. sensor input : 2 point DPR-TH1 : NTC 5k, ±0.3°C at 25°C(-50~105°C) FX32R Showcase](https://reader031.vdocuments.mx/reader031/viewer/2022021421/5ab587cd7f8b9ab47e8cf76c/html5/thumbnails/3.jpg)
Sensing Technology Corporation 457-B Boni Avenue New Zaniga Mandaluyong City Tel No. 532-0088 Fax No. 531-7387www.heatsenze.com [email protected]
FX3S
FX3FS
out1 : heating/cooling output
OUT1 : Heating/cooling outputOUT2 : Heating/cooling ouput
- Timer output- Sensor error detection
alarm output- Heater defrost output- Hot gas defrost output
NTC Cooling ThermostatHeating DefrostDigital Temperature Controller NTC Cooling Defrost 4~20mA RS485 RetransHeatingDigital Temperature Controller
Main-Function
Input/output
Models
Power Supply
Sensor Spec
Heating/cooling output, precise temperature control, sensorcorrection, sensor detection, data backup, min. on/off maintainingtime setup, auto-output operation cycle settable in case of sensorerror
AC100~240V, 50/60Hz, Max. 4VA, screw bolt terminals
Relay output : 1point (16A), Temp. sensor input : 1 point (NTC)
DPR-TH1 : NTC 5k, ±0.3°C at 25°C(-55~105°C)DPR-TH2 : NTC 10k, ±0.3°C at 25°C (-50~150°C)
FX3S-00 : Basic model (with DPR-TH1-ET temperature sensor)
FX3D
Main-Function
Input/output
Models
Power Supply
Sensor Spec
Heating/cooling output, independent timer output, high/low alarmoutput, defrost output, precise temperature control, sensor correction,sensor error detection, data backup, min. on/off maintaining time setup,RS485 communication (MODBUS), auto-output operation cyclesettable in case of error, transmission output
AC100~240V, 50/60Hz, Max. 4VA, screw bolt terminals
Relay output : 1point (16A), Temp. sensor input : 1 point (NTC)4~20mA Input : 1 point (including power supply)
DPR-TH1 : NTC 5k, ±0.3°C at 25°C(-55~105°C)DPR-TH2 : NTC 10k, ±0.3°C at 25°C (-50~150°C)
FX3S - 00 : Basic model (with DPR-TH1-ET temperature sensor)FX3D-R4 : Add on Rs485 communication (MODBUS)FX3D - A4 : Add on 4~20mA transmission outputFX3D - R2 : Add on RS232 communicationFX3D - A1R4 : Add on 4~20mA transmission output,RS485 communication (MODBUS)
4~20mAsignal input
4~20mAwiring method for loop power sensor
Cooling RetransHeatingNTCDigital Temperature Controller
OUT1 : hea�ng/cooling on/off output Save : T1 - temperature sensor#1 T2 - temperature sensor#2
1 2 4 5 6 8 9
B1
10
B2COM
FX3FS-00
L2L1
AC100-240V ~
POWER
50/60HzNTC
T2T1
OUT
c
16A, 250Vac
Main-Function
Input/output
Models
Power Supply
Sensor Spec
Heating/cooling output, precise temperature control, sensor correction,sensor error detection, data back up, min. on/off maintaining timesetup, defrost output, virtual input function, function to preventincorrect operation caused by sensor error
AC100~240V, 50/60Hz, Max. 4VA, screw bolt terminals
Relay output : 1point (16A), Temp. sensor input : 1 point (NTC)
DPR-TH1 : NTC 5k, ±0.3°C at 25°C(-55~105°C)DPR-TH2 : NTC 10k, ±0.3°C at 25°C (-50~150°C)
FX3S - 00 : Basic model (with 2 pcs ofDPR-TH1-ET temperature sensor)
FX3T Cooling RS485 RetransHeatingCA(K)Digital Temperature Controller
n1 n2 n3
n1 : HEAT/COOL #1 ON/OFF output, alarm output
n2 : HEAT/COOL #2 ON/OFF output,
alarm output
n3 : HEAT/COOL #3 ON/OFF output,
alarm output
Main-Function
Input/output
Models
Power Supply
Sensor Spec
Heating/cooling output, high/low alarm output, precise temperaturecontrol, sensor correction, sensor error detection, data backupmin. on/off maintaining time setup, transmission output, RS485communication (MODBUS)
AC100~240V, 50/60Hz, Max. 4VA, screw bolt terminals
Relay output : 3point (10A), Temp. sensor input : 1 point (thermo-couple)
Thermo-couple K type : Measuring range : 0~1000°C
FX3S - 00 : Basic model (with 2 pcs ofDPR-TH1-ET temperature sensor)
DIGITAL TEMPERATURE CONTROLLER
FX Series
SENSETE°C
H®
CW
CH
EAT-ED
GE®
RA
INB
OW
SHIM
AD
ENP
R ELEC
TRO
NIC
SKIM
OSEKO
NIC
HU
BA
KA
ISEO
HK
UR
AC
OR
DEX
FRIED
ELECTR
ICD
OTEC
H
V-A1
![Page 4: DOTECH SENSING & CONTROL - · PDF fileDOTECH SENSING & CONTROL ... Relay output : 4point, Temp. sensor input : 2 point DPR-TH1 : NTC 5k, ±0.3°C at 25°C(-50~105°C) FX32R Showcase](https://reader031.vdocuments.mx/reader031/viewer/2022021421/5ab587cd7f8b9ab47e8cf76c/html5/thumbnails/4.jpg)
Sensing Technology Corporation 457-B Boni Avenue New Zaniga Mandaluyong City Tel No. 532-0088 Fax No. 531-7387www.heatsenze.com [email protected]
FX3QR / FX3SR Cooling RS485 RetransHeatingPT100Digital Temperature Controller
n1 : HEAT/COOL #1 output, event outputn2 : HEAT/COOL #2 output, event outputn3 : HEAT/COOL #3 output, event outputn4 : HEAT/COOL #4 output, event output
n1 : Hea�ng/cooling #1 ON/OFF output, event output
n1 n2 n3 n4
N1,2 : 10A, 250VN3,4 : 5A, 250V
Main-Function
Input/output
Models
Power Supply
Sensor Spec
Heating/cooling output, precise temperature control, data backup,min. on/off maintaining time setup, relay output manually controllable,transmission output, sensor correction, sensor error detection, RS485communication (MODBUS)
AC100~240V, 50/60Hz, Max. 4VA, screw bolt terminals
FX3QR : Relay output : 4 point, Temp. sensor input : 1 point (Pt100)FX3SR : Relay output : 1 point (16A), temp. sensor input : 1 point (Pt100)
Pt100 3(2) Wire, Measuring range : -200~800°C, ±0.3°C
FX3QR / FX3SR-00 : Basic modelFX3QR / FX3SR-R4 : Add on RS485 communication (MODBUS)FX3QR /FX3SR-A1 : Add on 4~20mA transmission outputFX3QR /FX3SR-A1 : Add on RS232 communication
DIGITAL HUMIDITY CONTROLLER
FX3H HumidityDigital Humidity Controller
1 2 4 5 6 9 10 11
COM
POWER
OUT1FX3H
cL2L1
AC100 - 240V ~50/60Hz
Vin
16A, 250Vac
+5V
% Humidity
RW(Y)
B
OUT1: Dehumidifica�on/Humidifica�on #1 ON/OFF outputCOM : Signal input common terminalVin : Humidity sensor input+5V : Power Supply for humidity sensor (5Vdc)
Main-Function
Input/output
Models
Power Supply
Sensor Spec
Humidication/dehumidication input, high/low alarm output,min. on/off maintaining time setup, selection on/off output whensensor error occurs, sensor correction, sensor error detection,selection of displaying decimal point
AC100~240V, 50/60Hz, Max. 4VA
Relay output : 1 point (out1 : 250Vac/16A),Humidity 1~4V, input : 1 point
HTX20-FTS-502 (Voltage output type humidity sensor), HTX3515
FX3H - 00
FX3DH HumidityCoolingHeatingNTCDigital Temp. & Humidity Controller Thermostat 4~20mA Retrans
1 2 3 4 5 6 7 8 9 10 11
COMNTC
POWER
OUT1 OUT2
HumidityTEMP
FX3DH OP
TION
MO
DU
LE
cL2L1
AC100 - 240V ~50/60Hz
R
Vin
8(2)A, 250Vac
+5V
W(Y)
B
%
OUT1 : Humidifica�on/dehumidifica�on #1 ON/OFF outputOUT2 : Humidifica�on/dehumidifica�on #2 ON/OFF outputCOM : Signal input common terminalVin : Humidity sensor inputNTC : Temp. sensor input+5V : Power for humidity sensor(5Vdc)
Main-Function
Input/output
Models
Power Supply
Sensor Spec
Humidication (heating), dehumidication (cooling) ouput, high/lowalarm output, min. on/off maintaining time setup, selection on/off output when sensor error occurs, sensor correction, sensor errordetection, relay output manual control, transmission output, RS485communication (MODBUS)
AC100~240V, 50/60Hz, Max. 4VA
Relay output : 1 point (out1 : 250Vac/8(2)A),Humidity 1~4V, input : 1 point
HTX20-FTS-502 (Voltage output type humidity sensor), HTX3515
FX3H - 00 : Basic modelFX3DH - R4 : Add on RS485 communication (MODBUS) FX3DH - A1 : Add on 4~20mA transmisson outputFX3DH - R2 : Add on RS232 communication
DIGITAL TEMPERATURE CONTROLLER
FX Series
SEN
SETE
°CH
®C
WC
HEA
T-ED
GE®
RA
INB
OW
SHIM
AD
ENP
R E
LEC
TRO
NIC
SSE
KON
ICH
UB
A
KA
ISE
OH
KU
RA
CO
RD
EXFR
IED
ELE
CTR
ICK
IMO
DO
TEC
H
V-A2
![Page 5: DOTECH SENSING & CONTROL - · PDF fileDOTECH SENSING & CONTROL ... Relay output : 4point, Temp. sensor input : 2 point DPR-TH1 : NTC 5k, ±0.3°C at 25°C(-50~105°C) FX32R Showcase](https://reader031.vdocuments.mx/reader031/viewer/2022021421/5ab587cd7f8b9ab47e8cf76c/html5/thumbnails/5.jpg)
REFRIGERATION CONTROLLER
FX32J NTC Retrans4~20mARS485Showcase & Coldroom Controller
COMP, DEF : 10A, 250Vac FAN, AUX : 5A, 250Vac
COMP FAN DEF AUX
comp: compressor(SOL) control outputfan: fan control outoutdef: defros�ng control outputal/aux: alarm/defros�ng synchroniza�on/
hea�ng control output
AMB.T : inside temperature sensorDEF.T : sensor for return temperature a�er
sensor for defrost recovery
FX32J – 00 : Basic model FX32J– R4 : Add on RS485 communication (MODBUS)FX32J– A1 : Add on 4~20mA transmission outputFX32J– L1 : adopted printer for recoderFX32J– L2 : added data logger function FXP-60 : recording printer for FX32J-L1
Main-Function
Input/output
Models
Power Supply
Sensor Spec
Defrosting (auto/manual), fan control, efcient delayRoom temperature sensor : 1EA, defrost recovery sensor : 1EA.High (low) temp. alarm output, room temp. transmission output(4~20mA), RS85 communication (MODBUS)
AC100~240V, 50/60Hz, Max. 4VA, screw bolt terminals
Relay output : 4point, Temp. sensor input : 2 point
DPR-TH1 : NTC 5k, ±0.3°C at 25°C(-50~105°C)
FX32R NTC RS485Showcase & Coldroom Controller
comp: compressor(SOL) control outputfan: fan control outoutdef: defros�ng control outputal/aux: alarm/defros�ng synchroniza�on/
hea�ng control output
B1-AMB : inside temperature sensorB2-DEF : sensor for return temperature a�er
sensor for defrost recoveryB3-EXT : outlet temperature sensor
ID1-D.SYC: defros�ng syncroniza�on signal inputID2-I.LOCK: interlock signal inputID3-FAN.AL: fan alarm signal inputID4-EMG.C: emergency(locking) switch signal inputID5-NIGHT: NIGHT SETBACK signal inputID6-DOOR: door open switch signal inputID7-REMOTE : remote opera�on stop signal input
Main-Function
Input/output
Models
Power Supply
Defrosting (auto/manual), defrosting stop delay, evaporation fancontrol, air inlet/outlet sensor : 2EA, defrost recovery sensor : 1EA,virtual temp. sensor computing, door open alarm, emergency call,interlock, defrost activation, night operation, high (low) temp. alarmoutput, RS85 communication (MODBUS)
AC100~240V, 50/60Hz, Max. 8VA, connector (Molex)
Relay output : 4point, Digital input : 7 point,Temp. sensor input : 3 point
FX32R– 00 : Basic model FX32R– R4 : Add on RS485 communication (MODBUS)
FX32K 4~20mA RS485DefrostDefrost factor Controller
4~20mA RS485DefrostDefrost factor Controller
B1 : Ambient humidity 4~20mA inputB2 : Ambient temperature sensor inputB3 : Refrigerant suc�on temperature
sensor inputID1 : Interlock signal
def : Defrost ON/OFF outputal/aux : Alarm output
Main-Function
Input/output
Models
Power Supply
Sensor Spec
Efcient defrosting in geothermy heat pump systemDefrosting execution by measuring of ambient humidityand temperature
AC100~240V, 50/60Hz, Max. 4VA, screw bolt terminals
Relay output : 4point, Temp. sensor input : 2 point
Relay output : 2 point, Digital input : 1 point,Temp. sensor input : 2(3) point, humidity sensor input : 1 point
FX32K–00 : Basic model FX32K–30 : Add on humidity sensorFX32K–30-R4 : Add on RS485 communication (MODBUS)
FX32C NTC RS485Comptector
comp : COMP RUN/STOPsol : SOL V/V ON/STOPinj : INJECTION SOLal/aux : Alarm
B1 : AMBIENT TEMPB2 : SPAREB3 : DISCHARGE GAS TEMP
ID1 : OCRID2 : INTID3 : HPSID4 : OPS / PMRID5 : LPSID6 : INTERLOCKID7 : RUN/STOP
Main-Function
Input/output
Models
Power Supply
Sensor Spec
Total control and detection (protection) for freezers, function of start,restart, pump down, alarm delay timer, discharge gas detection(high & low temp.), individual alarm message (OC, HP, LP, OP, INT, etc),liquid injection (discharge gas detection), communication (RS485 MODBUS)
AC100~240V, 50/60Hz, Max. 8VA, connector (Molex)
Relay output : 4point, Temp. sensor input : 2 point
Relay output : 4 point, Digital input : 7 point,Temp. sensor input : 3 point
FX32C–00 : Basic model FX32C–30-R4 : Add on RS485 communication (MODBUS)FX32C–30 : add on gas discharge protection and controlFX32C–40 : add on added gas discharge temperature and inside
temperature control function
FX Series
SENSETE°C
H®
CW
CH
EAT-ED
GE®
RA
INB
OW
SHIM
AD
ENP
R ELEC
TRO
NIC
SKIM
OSEKO
NIC
HU
BA
KA
ISEO
HK
UR
AC
OR
DEX
FRIED
ELECTR
ICD
OTEC
H
V-A3
Sensing Technology Corporation 457-B Boni Avenue New Zaniga Mandaluyong City Tel No. 532-0088 Fax No. 531-7387www.heatsenze.com [email protected]
![Page 6: DOTECH SENSING & CONTROL - · PDF fileDOTECH SENSING & CONTROL ... Relay output : 4point, Temp. sensor input : 2 point DPR-TH1 : NTC 5k, ±0.3°C at 25°C(-50~105°C) FX32R Showcase](https://reader031.vdocuments.mx/reader031/viewer/2022021421/5ab587cd7f8b9ab47e8cf76c/html5/thumbnails/6.jpg)
POWERCMP
B1-A
MB
G G
G
J2
J1
1
8
7
14
7
1
12
6
-G+
RS485, MODBUS
FX32S
FX iview
POWER
DEF
CMP
B3-E
XT
B2-D
EF
B1-A
MB
G G
G
J2
J1
1
8
7
14
7
1
12
6
-G+
RS485, MODBUS
FX32SD
FX iview
POWER
ALARM
CMP
B3-E
XT
B2-D
EF
B1-A
MB
G G
G
J2
J1
1
8
7
14
7
1
12
6
-G+
RS485, MODBUS
FX32SA
FX iview
POWER
FAN
CMP
B3-E
XT
B2-D
EF
B1-A
MB
G G
G
J2
J1
1
8
7
14
7
1
12
6
-G+
RS485, MODBUS
FX32SF
FX iview
POWER
DEFFAN
CMP
B3-E
XT
B2-D
EF
B1-A
MB
G G
G
J2
J1
1
8
7
14
7
1
12
6
-G+
RS485, MODBUS
FX32SB
FX iview
POWER
ALARM
DEFFAN
CMP
B3-E
XT
B2-D
EF
B1-A
MB
G G
G
J2
J1
1
8
7
14
7
1
12
6
-G+
RS485, MODBUS
FX32SR
FX iview
FX32PR 4~20mA RetransRS485Digital Low/High Pressure Controller
RS-485CO MM.
OPTION MODULE
1
2
3
4
TRX
TRX
SG
1
2
3
4
RXD
TXD
GND
1
2
3
4
4~20mA
4~20mA
SG
RS-232COMM.
OPTION MODULE
4~20mA Output
OPTION MODULE
Main-Function
Input/output
Models
Power Supply
Uniform step control, operation with intelligent shifthigh/low alarm output, sensor correction, sensor error detection,transmission output, communication (RS485 MODBUS)
AC100~240V, 50/60Hz, Max. 4VA
One sensor input of 4~20 mA (embedded sensor loop power),Four relays (three relays for step control, one relay for alarm output)
FX32PR–00 : Basic model FX32PR–R4 : Add on RS485 communication (MODBUS)FX32PR–A1 : Add on 4~20mA transmission output
FX32EV RetransRS485Pt1000 4~20mAElectronic Expansion Valve control system
1 2 43 5 6 87 9 10 11
AC100 - 240V ~
pressure
50/60Hz
FX32EV OP
TION
MO
DU
LE
tempstart
EVout
Alarm
EV
ID1 Pt1k COM 4~20mA +V
Main-Function
Input/output
Models
Power Supply
PID degree of superheat control through defense and safetycompensation, degree of superheat control for various refrigerant,PMW (opening ratios control), remote operation, transmission output,RS485 communication (MODBUS)
AC100~240V, 50/60Hz, Max. 4VA, screw bolt terminals
SSR output 1-point (expansion valve on/off), relay output 1-point(alarm point), temperature sensor 1-point, 4~20mA pressure sensorinput 1-point (embedded sensor loop power)
Sensor Spec Temp. sensor (DPR-PT1K-P6D5OL, -100~100°CPressure sensor (-1~9 bar or 0~30 bar)
FX32EV– 00 : Basic model FX32EV– R4 : Add on RS485 communication (MODBUS)FX32EV– A1 : use for 4~20mA type Electronic Expansion Valve or
pressure transmission output functionFX32EV– R2 : Add on RS232 communication
FX32S series NTC RS485Showcase & Coldroom Controller
Compressor
Defrost
Eva Fans
Aux.output
Room Temp.
Defrost Temp.
Digital Input(Probe3)
RTC
RS485
16A
-
-
-
●
-
-
-
◎
16A
8A
-
-
●
●
●
-
◎
16A
-
-
8A
●
●
●
-
◎
16A
-
8A
-
●
●
●
-
◎
16A
8A
8A
-
●
●
●
-
◎
8A
8A
8A
8A
●
●
●
-
◎
FX32SModels FX32SD FX32SA FX32SF FX32SB FX32SR
● : Basic◎ : Option
Main-Function
Input/output
Sensor Spec
Power Supply
Defrosting (auto/manual), defrosting stop delay, two air inlet andoutlet sensors, one sensor for defrost recovery, high(low) alarmoutput, RS485 communication (MODBUS), indicator (FxiView)connection
AC100~240V, 50/60Hz, Max. 8VA, connector (Molex)
relay output max 4-point, temperature sensor input max 3 point
DPR-TH1 : NTC 5k, ±0.3°C at 25°C (-50~105°C)
REFRIGERATION CONTROLLER
FX Series
SEN
SETE
°CH
®C
WC
HEA
T-ED
GE®
RA
INB
OW
SHIM
AD
ENP
R E
LEC
TRO
NIC
SSE
KON
ICH
UB
A
KA
ISE
OH
KU
RA
CO
RD
EXFR
IED
ELE
CTR
ICK
IMO
DO
TEC
H
V-A4
Sensing Technology Corporation 457-B Boni Avenue New Zaniga Mandaluyong City Tel No. 532-0088 Fax No. 531-7387www.heatsenze.com [email protected]
![Page 7: DOTECH SENSING & CONTROL - · PDF fileDOTECH SENSING & CONTROL ... Relay output : 4point, Temp. sensor input : 2 point DPR-TH1 : NTC 5k, ±0.3°C at 25°C(-50~105°C) FX32R Showcase](https://reader031.vdocuments.mx/reader031/viewer/2022021421/5ab587cd7f8b9ab47e8cf76c/html5/thumbnails/7.jpg)
MULTI-FUNCTION DIGITAL CONTROLLER
FX32P RS485 Retrans4~20mAPressure Switch Controller
c
1 2 3 4 5 6 7 8 9 10 11
COM mA +12VL2L1
AC100 - 240V~SENSOR50/60Hz
FX32P OP
TION
MO
DU
LE
L1
L2
N1 N2 N3 N4
N1,2 : 10A, 250V N3,4 : 5A, 250V
+
2wire
3wire
N1 : decrease pressure / increase pressure #1 ON/OFF output, event output
N2 : decrease pressure / increase pressure #2 ON/OFF output, event output
N3 : decrease pressure / increase pressure #3 ON/OFF output, event output
N4 : decrease pressure / increase pressure #4 ON/OFF output, event output
FX32P– 00 : Basic model FX32P– R4 : Add on RS485 communication (MODBUS)FX32P– A1 : Add on 4~20mA transmission output
Main-Function
Input/output
Models
Power Supply
Output controllable based on measured pressure value (increase and decrease),alternative operation available between freezing exclusive model and booster,pump unit control exclusive model, RS485 communication (MODBUS)
AC100~240V, 50/60Hz, Max. 4VA, screw bolt terminals
relay output : 4 point, Input sensor : 1 point (including power supply)
Sensor Spec 4~20mA (2 wire or 3 wire)
FX32F NTC Heating Cooling RS485Fan Coil Unit Controller
FX32F
AC100-240V~50/60Hz FAN
LO MD HI COM
B/T AMBTEMP
1 2 3 4 5 6 7 8 9 10 11 12 13
2A 250Vac
POWER
OP
TION
MO
DU
LE
L2 B2 B1G GL1
AM
B. T
EM
PS
EN
SO
R
CO
IL T
EM
PS
EN
SO
R
LO : low wind speed on/off outputMD : midium wind speed on/off outputHI : high wind speed on/off output
G : signal input common terminalB1 : Ambient temperature sensor inputB2 : coil temerature sensor input
Main-Function
Input/output
Models
Power Supply
3 stage fan speed controllable, 4 kind (stop/high/middle/low) airow choosable,unication of temp. control function, data backup, self diagnostic, RS485communication (MODBUS)
AC100~240V, 50/60Hz, Max. 4VA, connector
relay output : 3 point (airow control),Temp. sensor input : 2 point (room & water)
Sensor Spec DPR-TH1 : NTC 5k, ±0.3°C at 25°C (-50°C~105°C)
FX32F– 00 : Basic model FX32F– R4 : Add on RS485 communication (MODBUS)
comp : main motor on/off outputsol : LOAD SOL ON/OFF outputB1 : pressure sensor input signalB2 : temperature sensor input signal
ID1 : control output interlock signal(OCR, EMSW)ID2 : remote run / stop control signal
FX32A RS485NTC Retrans4~20mAAir Compressor Controller
Main-Function
Input/output
Models
Power Supply
Embedded run/stop switch, motor on/off, load run, auto-stop, manualstop, operation delay, load delay, embedded timer,pressure/temerature high level, temperature low level (standby forstarting), interlock input signal (emergency switch, OCR reverse phase),Usable thermometer and manometer, RS485 communication(MODBUS)
AC100~240V, 50/60Hz, Max. 4VA, screw bolt terminals
Relay output : 2 point (motor, SOL)Digital input : 2 point (interlock, remote control)Temp. sensor input : 1 point (discharge air temperature)Pressure sensor input : 1 point (discharge air pressure)
Sensor Spec DPR-TH2 : NTC 10k, ±0.3°C at 25°C (-50°C~150°C)
FX32A-351 NTC RS485 Retrans4~20mAAir Compressor Controller
1 2 3 4 5 6 7 8 9 10 11
+VDCCOMB2B3ID1
FX32A-351
B1
OP
TION
MO
DU
LE
L1
L2
L2L1
AC100 - 240V ~50/60Hz
3A 250Vac
C1 C2 C
ID1 : remote run/stop signalC1 : COMP1 motor ON/OFF outputC2 : COMP2 motor ON/OFF output
B1 : pressure sensor input signalB2 : COMP1 temp. sensor input signalB3 : COMP2 temp. sensor input signal
FX32A– 00 : Basic model FX32A– R4 : Add on RS485 communication (MODBUS)FX32A– A1 : Add on 4~20mA transmission outputFX32A– R2 : Add on RS232 communication
Main-Function
Input/output
Models
Power Supply
Embedded run/stop switch, motor on/off, load run, auto-stop, manualstop, operation delay, load delay, embedded timer,pressure/temerature high level, temperature low level (standby forstarting), interlock input signal (emergency switch, OCR reverse phase),Usable thermometer and manometer, RS485 communication(MODBUS)
AC100~240V, 50/60Hz, Max. 4VA, screw bolt terminals
Relay output : 2 point (motor, SOL)Digital input : 2 point (interlock, remote control)Temp. sensor input : 1 point (discharge air temperature)Pressure sensor input : 1 point (discharge air pressure)
Sensor Spec Pressure Sensor : 0~16 bar (4~200mA)DPR-TH2 : NTC 10k, ±0.3°C at 25°C (-50°C~150°C)
FX32A-351-00 : Basic model FX32A-351-R4 : Add on RS485 communication (MODBUS)FX32A-351-A1 : Add on 4~20mA transmission outputFX32A-351-R2 : Add on RS232 communication
FX Series
SENSETE°C
H®
CW
CH
EAT-ED
GE®
RA
INB
OW
SHIM
AD
ENP
R ELEC
TRO
NIC
SKIM
OSEKO
NIC
HU
BA
KA
ISEO
HK
UR
AC
OR
DEX
FRIED
ELECTR
ICD
OTEC
H
V-A5
Sensing Technology Corporation 457-B Boni Avenue New Zaniga Mandaluyong City Tel No. 532-0088 Fax No. 531-7387www.heatsenze.com [email protected]
![Page 8: DOTECH SENSING & CONTROL - · PDF fileDOTECH SENSING & CONTROL ... Relay output : 4point, Temp. sensor input : 2 point DPR-TH1 : NTC 5k, ±0.3°C at 25°C(-50~105°C) FX32R Showcase](https://reader031.vdocuments.mx/reader031/viewer/2022021421/5ab587cd7f8b9ab47e8cf76c/html5/thumbnails/8.jpg)
Digital Input Port
Digital Output Port
Temperature Sensor Input
Humidity Sensor Input
Diff. Pressure Sensor Input
Refrigerator Compressor Control Step
Heater Control Step
Humidify Control Step
Dehumidify Control Step
Main Brower Fan on/off Control
Dehumidier Control Function
React Heater Temp. Sensor Input
React Heater Control Function
React Heater Control Step 4 -
React Fan on/off Control 1 -
10
12
2
1
1
2 4
7
4
4
1
OK
OK
OK
4
1
10
12
1
1
-
2
5
2
-
1
-
-
-
-
-
-
-
OK(P control)
OK(P control)
OK(P control)
OK(P control)
OK(P control)
-
-
-
-
-
-
-
OK
OK
OK (PID control)
OK (PID control)
OK (PID control)
OK (PID control)
OK (PID control)
OK
OK
OK
OK
OK
OK
OK
Trip / Alarm Recording Function
Schedule Run/Stop Function
Cool / Dehumidify Analog Control
Cooling Analog Control
Heating Analog Control
Humidify Analog Control
Diff. Pressure Analog Control
Temperature Retransmission Output
Humidify Retransmission Output
Diff. Press. Retransmission Output
React Heater SCR on/off Control
Heater SCR on/off Control
Humidify Heater SCR on/off Control
Cooling State on/off Control
Main Specication
Models Models
Main SpecicationDX100DX120 DX120DX140 DX140
DX100 series based on microprocessor has realized the best control and stability with efcient
control for HVAC units (AHU, constant temperature & humidity unit and control (dehumidier) and
perfect interface with safety devices. Its elegant graphic LCD display and LED helps users to check
the current state of the units.
- Temperature & humidity control function, Max. 6 loop of independent step
operating function
- Alternative operation by max. 4 compressors and 8 heaters
- Backup operating function
- Prevention from frequent starting failure occurred by low pressure hunting using
low pressure switch in compressor
- Successive starting function, pump down function and prevention from restarting
- Control function for cold water, hot water, steam valve, SCR, damper designed for
- Detection of error in temperature and humidity sensor, Alarm function, Output of
function
HVAC (4~20mA PID control)
of equipment state (Cooling and Dehumidication, Heating and Humidication)
- DX100 : HVAC Controller (2Comp) - DX120 : HVAC Controller (4Comp) - DX140 : Exclusive controller for constant temp. and humidity unit
MENU SELECT
RUN INFO
OPERATION
SCHEDULE
TRIP LOG
OPERATION
SET TEMPERATURE : 25.0°C SET HUMIDITY : 50.0 %COOL DIFFERENCE : 200 PaHEAT DIFFERENCE : 120 ℃DEHUMIDITY DIFF : 1.0 ℃
▶
TRIP LOG00 080102 15:55 FIRST POWER ON
01 080102 16:10 FAN FAULT
02 080102 16:30 COMP#1 FAULT
03 080102 16:30 COMP#2 FAULT
04 080102 16:45 HEATER FAULT
TRIP LOG STATE
COMP#1 FAULT ON 080102 16:30
TEMO : -20.0°C HUM : 15.0%ID (10~1):N (12~1):
08:20
08
STAND BY
25.0 25.0PV SP
CM1SL1
C1A LP1LP2C2A RHAAFS
LOC STP
BRA RET
CM2SL2 ALR BROH1 H2 H3 H4 H5
C C
CurrentTemperature
Set Temp.
Temperature Single Control Display
08:20
08
DPS. ALARM
25.025.0
50.050.0
PV
SP
PV
SP
CM1SL1
C1A LP1LP2C2A RHAAFS
LOC STP
HUA BRA RET
CM2SL2 HUD ALR BROH1 H2 H3 H4 H5
C %Current Temperature
Set Temperature
Digital Output State
Opera�on State
Digital Input State
Lock Signal
Current Humidity
Current Time
Set Humidity
Alarm Message
Equipment State Code
Temperature + Humidity Control Display
08
STAND BY
50.0 50.0PV SP
CM1SL1
C1A LP1LP2C2A HUAAFS
LOC STP
BRA RET
CM2SL2 HUD ALR BRO
CurrentHumidity
Set Humidity%%
Humidity Single Control Display
X
08:20
DX100 / DX120 / DX140 HVAC Controller
DX Series
SEN
SETE
°CH
®C
WC
HEA
T-ED
GE®
RA
INB
OW
SHIM
AD
ENP
R E
LEC
TRO
NIC
SSE
KON
ICH
UB
A
KA
ISE
OH
KU
RA
CO
RD
EXFR
IED
ELE
CTR
ICK
IMO
DO
TEC
H
V-B6
Sensing Technology Corporation 457-B Boni Avenue New Zaniga Mandaluyong City Tel No. 532-0088 Fax No. 531-7387www.heatsenze.com [email protected]
![Page 9: DOTECH SENSING & CONTROL - · PDF fileDOTECH SENSING & CONTROL ... Relay output : 4point, Temp. sensor input : 2 point DPR-TH1 : NTC 5k, ±0.3°C at 25°C(-50~105°C) FX32R Showcase](https://reader031.vdocuments.mx/reader031/viewer/2022021421/5ab587cd7f8b9ab47e8cf76c/html5/thumbnails/9.jpg)
DX200 / DX240 / DX270
DX200 series based on microprocessor has realized the best control and stability with deciding
and controlling capacity adjustment timing for screw compressor and perfect interface with safety
devices.
- Efcient step/stepless control, convenience for operation and inspection
- One-touch setup function (Choosing the maker -> Automatic setup according to
their basic spec.) (Bitzer, Hitachi, Refcomp, Fusheng, Hanbell, Mitsubishi, Roltec, Kobe)
- Strong timer function (Step delay, Start delay, Auto-stop delay, Restart delay,
Pump down delay)
-Temperature control, Pressure control (input temperature, output temperature,
Intake pressure control, Discharge gas temperature control and observation)
- DX200 : 1 Cycle Screw Compressor Controller
- DX220 : 1~2 Cycle Screw Compressor Controller
- DX240 : 1~4 Cycle Screw Compressor Controller
- DX270 : 1 Cycle Screw Compressor Controller (Step Control)
- DX200H : 1 Cycle Screw Heat Pump Compressor Controller
- DX220H : 1~2 Cycle Screw Heat Pump Compressor Controller
MENU SELECT
RUN INFO
OPERATION
TRIP LOG
TRIP & ALARM
OPERATION
Set Point : 10.0 ℃1 Step Start Devia�on : +3.0 ℃2 Step Start Devia�on : +4.0 ℃1 Step Stop Devia�on : - 2.0 ℃2 Step Stop Devia�on : - 1.0 ℃
▶
TRIP & ALARM
Pump(Fan) Interlock Delay : 0 sec
Pump(Fan) Interlock Hold : 2 sec
Discharge Gas Over Temp : 105 ℃Freezing Protec�on Temp : 2.0 ℃Low Temp Alarm : 5.0 ℃
TRIP LOG23 000101 00:00 Low Temp Alarm
24 000101 00:00 Outlet T-Sense Fault
25 000101 00:00 DC Gas#1 T sensor
26 000101 00:00 DC Gas#2 T sensor
7 000101 00:00 X Low Temp Alarm
Current Temperature
Digital Output State
Opera�on State
Digital Input State
Lock Signal
Set Temperature
Current Time
Discharge Gas Temperature
Alarm Message
Equipment State Code
7.0
08:20
51
14
STAND BY
25.5PV SP
D.C GAS :
INCDECSTSSOL LIS PM
OCC
LOC STP
LPSREV HPS
CM CY CD ALR
C C
C
ㅇDX200 (Stepless)
Current Temperature
Digital Output State
Opera�on State
Digital Input State
Lock Signal
Set Temperature
Current Time
Discharge Gas Temperature
Alarm Message
Equipment State Code
7.0
08:20
51
14
START READYGOOD
25.5PV SP
D.C GAS :
SOL LIS PM
OCC FSPILRET
LOC STP
OLS OVHREV LPS HPS
CM CY CD ALR
C C
C
S1% S2% S3%
ㅇDX270 (Step)
AC 220V50/60Hz
NOISEFILTER
100
AC TRANSFORMERAC 220V / 24V, 30VA
G0 (NEUTRAL)
G (HOT)
External Capcity Control4~20mAdc / 0~100%
Overload Main Motor
Reverse Phase Main Motor
LPS
HPS
Oil Level Switch
Over-Temp Main Motor
Remote Run/Stop
Overload Condensor-Fan Motor
Interlock Pump(Fan), Flow Switch
Overload Pump(Fan) Motor Alarm
G (HOT)
G (HOT)
FUSE
FUSE
UIC DX200 Series
TERMINALNO
TERMINAL NO
+
-
+
-
+
-
DESC. DESC.
N1 J21 - 1
J21 - 2
J21 - 3
J21 - 4
J21 - 5
J22 - 1
J22 - 2
J22 - 3
J22 - 4
J22 - 5
J23 - 1
J23 - 2
J23 - 3
J23 - 4
J23 - 5
N2
N3
N4
C1
N5
N6
N3
N8
C2
N9
N10
N11
N12
C3
J6 - 1
※ Shield Wire UseConnection Frame and BuildingGround
J6 - 2
J6 - 3
J6 - 4
J6 - 5
J6 - 6
Y1
Y2
Y3
YG2
YG1
YG3
J1 - 1
J11 - 1 +24VB4 SPARE
External CapcityControl Signal
Inlet Temp Sensor(-40~70℃)
Outlet Temp Sensor(-40~70℃)
B5AVSS
B1AVSS
AVSSB2
B3 DIS-GAS(-20~200℃)
Overload Main Motor
Over-Temp(INT TC)
Overload Fan Motor
Flow Switch
Interlock Pump
Remote On/Off Signal
ID COMMON 2
Rev-Phase Main Motor
Low Press. Switch
High Press. Switch
Oil Level Switch
ID COMMON 1
J11 - 2
J11 - 3J11 - 4
J12 - 1
J12 - 2
J12 - 3
J12 - 4
J12 - 5
J13 - 5
J13 - 6
J13 - 4
J13 - 3
J13 - 2
J13 - 1 ID1
J14 - 1 ID6
SYSTEM BUS RS485
LOCAL BUS RS485
J14 - 2 ID7
J14 - 3 ID8
J14 - 4 ID9
J14 - 5 ID10
J14 - 6
TB1 - 1 GNDB
A
GNDB
A
TB1 - 2TB1 - 3
TB2 - 1
TB2 - 2
TB2 - 3
* OPTION
* OPTION
IDCM2
ID2
ID3
ID4
ID5
IDCM1
J1 - 2
J1 - 3
FG
G0
G
LEGEND LEGEND
24VAC 50/60HzCONTROLLERPOWER INPUT
MMI CONNECTION(Only DX200-X1 MODEL)
EXTENTION BOARD
200
(to Slave Unit #2~#4)
250VAC 5A OUTPUT COMMON 1
OUTPUT COMMON 2
OUTPUT COMMON 3
Inlet Temp retrans.
Outlet Temp retrans.
DC Gas Temp retrans.
Analog Option (Only DX200-X1 Model)
SPARE
RUNNING STATE
ALARM(TOTAL)
PUMPON/OFF CONTROL
SOL for Liquid Injection
MC for Delta(D)
MC for Main / PW1
MC for Star(Y) / PW2
SOL V/VFOR LIQUID
LOAD CONTROLSTART SOL
LOAD CONTROLDECREASE SOL
LOAD CONTROLINCREASE SOL
100
FUSE
200
R1
R2
R5
R6
R7
R10
R11
R12
R8
R3
R4
Wiring Diagram (DX200 : Stepless)
Screw Compressor Controller
DX Series
SENSETE°C
H®
CW
CH
EAT-ED
GE®
RA
INB
OW
SHIM
AD
ENP
R ELEC
TRO
NIC
SKIM
OSEKO
NIC
HU
BA
KA
ISEO
HK
UR
AC
OR
DEX
FRIED
ELECTR
ICD
OTEC
H
V-B7
Sensing Technology Corporation 457-B Boni Avenue New Zaniga Mandaluyong City Tel No. 532-0088 Fax No. 531-7387www.heatsenze.com [email protected]
![Page 10: DOTECH SENSING & CONTROL - · PDF fileDOTECH SENSING & CONTROL ... Relay output : 4point, Temp. sensor input : 2 point DPR-TH1 : NTC 5k, ±0.3°C at 25°C(-50~105°C) FX32R Showcase](https://reader031.vdocuments.mx/reader031/viewer/2022021421/5ab587cd7f8b9ab47e8cf76c/html5/thumbnails/10.jpg)
DX220
DX200 series based on microprocessor performs best operation (control) automatically according
to set condition and unit ’s operation status which conducting efcient operation of 1~2 cycle
compressor.
- Stepless Capacity Control Type / built in equal control function
- Adapted wide graphic LCD, displaying Korean / English / Chinese
- Easy to analyze the cause of troubles because of storing 160 histories of trip message
- Embeded day-timer to enable energy-saving operation
- Various analog output function
(Outlet temperature / Discharge gas temperature transmission)
- Various applications (Chiller, CDU, Start control panel)
- User can use this model regardless of compressor’s maker
- User have only to input maker and setting of capacity Control valve is nished)
- DX220(H)-00 : Basic model
- DX220(H)-11 : Temperature transmission output function + RS485 communication
*H : Exclusive model for heat pump
(can set up Capacity Control Type)
(Modbus RTU)
Current Temperature
DigitalOutput State
Opera�on State
Lock Signal
Set Temperature
Current Time
Alarm Message
Equipment State Code
08 20
51
:
STAND BY
25.5PV SP :
IN :
GAS#1 :
GAS#1 :
10.0
0.8
25
45
ALR
C C
C
C
C
MENU SELECT
RUN INFO
OPERATION
TRIP LOG
TRIP & ALARM
OPERATION
SET VALUE : 7.0 ℃RUN DIFFERENTIAL : +1.0 ℃STOP DIFFERENTIAL : -0.5 ℃50% CAP. DIFFERENTIAL : +0.2 ℃75% CAP. DIFFERENTIAL : -0.2 ℃
▶
TRIP LOG
05 000101 00:00 COND-FAN FAULT
06 000101 00:00 COMP INT FAULT
07 000101 00:00 OUTLET SENS. FLT
08 000101 00:00 DS GAS SENS. FLT
09 000101 00:00 INLET SENS FLT
TRIP & ALARMFLOW SENSING DELAY : 60 ℃FLOW SENSING HOLD : 5 ℃DISCHARGE TEMP OVER : 115 ℃OUTLET TEMP FREEZE : 2.0 ℃LOW TEMP PROTECT : 5.0 ℃
LOC STP
Screen Composition MENU Composition
Wiring Diagram (DX220)
Screw Compressor Controller
DX Series
SEN
SETE
°CH
®C
WC
HEA
T-ED
GE®
RA
INB
OW
SHIM
AD
ENP
R E
LEC
TRO
NIC
SSE
KON
ICH
UB
A
KA
ISE
OH
KU
RA
CO
RD
EXFR
IED
ELE
CTR
ICK
IMO
DO
TEC
H
V-B8
Sensing Technology Corporation 457-B Boni Avenue New Zaniga Mandaluyong City Tel No. 532-0088 Fax No. 531-7387www.heatsenze.com [email protected]
![Page 11: DOTECH SENSING & CONTROL - · PDF fileDOTECH SENSING & CONTROL ... Relay output : 4point, Temp. sensor input : 2 point DPR-TH1 : NTC 5k, ±0.3°C at 25°C(-50~105°C) FX32R Showcase](https://reader031.vdocuments.mx/reader031/viewer/2022021421/5ab587cd7f8b9ab47e8cf76c/html5/thumbnails/11.jpg)
DX260
Applications
Screen Composition MENU Composition
Wiring Diagram (DX230)
DX260 series has realized the best control and stability with ideal control of the number of
equipment, such as equal & backup operation and perfect interface with safety devices. Its elegant
graphic LCD display and LED helps users to check the current state of the units.
Also, it provides users with the information about PM & trip alarm history for quick and easy treatment.
- Suitability for rack control of multi condensing unit
- Control for max. 8 compressors and 8 condensing fans
(Basic : 4 compressors + 4 condensers)
- Efcient control for the number of equipment
(Setting On/Off value per individuals and/or per between steps)
- Perfect equal control (Within 1 hour difference of the total accumulated operation time)
- Pressure/temperature control (Individual and/or interlocking control for intake
- Strong storing and/or monitoring function for trip alarm history/state (Max. 200 cases)
- Optimal function for condensing fan speed control (4~20mA PID control)
- Transmission output function (Pressure / Temperature transmission)
- PC monitoring system using RS485 communication based on MODBUS protocol
Compressor #1 Alarm
LOW PRESSURE
UIC DX260 Series Controller
TERMINALNO TERMINAL NO
J1 - 1
J11 - 1
J12 - 1
J13 - 1 ID1 COMP#1 ALARM
COMPRESSOR #1ON/OFF CONTROL N1 J21 - 1 R1
G G0
FUSE3AR2
R3
R4
R5
R6
R7
R8
R9
R10
R11
R12
AC 24V, 50/60Hz
J21 - 2
J21 - 3
J21 - 4
J21 - 5
J22 - 1
J22 - 2
J22 - 3
J22 - 4
J22 - 5
J23 - 1
J6 - 1J6 - 2
J6 - 3J6 - 4
J6 - 5
J6 - 6* MULTI - FUNCTION CONTROL (Selctable User)
MULTI FUNCTION (N9~N12)
* OFF* RUN STATE* RUN WAIT STATE* COMP RUN* FAN RUN* TOTAL ALARM* COMP ALARM* FAN ALARM* COMP ALL ALARM* FAN ALL ALARM
J23 - 2
J23 - 3
J23 - 4
J23 - 5
N2
N3
N4
C1
N5
N6
N7
N8
C2
N9
N10
N11
N12
C3
Y1YG1
Y2YG2
Y3YG3
COMPRESSOR #2ON/OFF CONTROL
COMPRESSOR #3ON/OFF CONTROL
COMPRESSOR #4ON/OFF CONTROL
CONDENSER #1ON/OFF CONTROL
TOTAL ALARMSTATE SIGNAL
COMP RUN/STOPSTATE SIGNAL
COMP ALL ALARMSTATE SIGNAL
SYSTEM RUN/STOPSTATE SIGNAL
OUTPUT COMMON 3
MULTI FUNCTIONANALOG#1(4~20mA)
MULTI FUNCTIONANALOG#2(4~20mA)
MULTI FUNCTIONANALOG#3(4~20mA)
CONDENSER #2ON/OFF CONTROL
CONDENSER #3ON/OFF CONTROL
CONDENSER #4ON/OFF CONTROL
OUTPUT COMMON 2
OUTPUTCOMMON 1
COMP#2 ALARM
COMP#3 ALARM
COMP#4 ALARM
FAN#1 ALARM
ID COMMON
ID2
ID3
ID4
ID5
IDC1
J13 - 2
J13 - 3
J13 - 4
J13 - 5
J13 - 6
J14 - 1 ID6 FAN#2 ALARM
FAN#3 ALARM
FAN#4 ALARM
INTERLOCK ALARM
REMOTE ON/OFF
ID COMMON
ID7
ID8
ID9
ID10
IDC2
J14 - 2
J14 - 3
J14 - 4
J14 - 5
J14 - 6
* Optional Spec.
* Optional Spec.
* Optional Spec.
TB1 - 1
SYSTEM BUS RS485
LOCAL BUS RS485
SG
B
A
SG
B
A
TB1 - 2
TB1 - 3
TB2 - 1
TB2 - 2
TB2 - 3
B1GND
TEMP INPUT-40 ~ 70
SPARE TEMP
℃
SPARE TEMP
B2
B3
GND
J12 - 2J12 - 3
J12 - 4
J12 - 5
+24VB4
LOW PRESSURE(4~20mA)
HIGH PRESSURE(4~20mA)
B5GND
J11 - 2
J11 - 3J11 - 4
FG
24VAC 50/60HzCONTROLLERPOWER INPUT
G0
G
J1 - 2
J1 - 3
DESC. DESC.LEGEND LEGEND
AC 220V50/60Hz
SURGEABSORBER
NOISEFILTER
AC TRANSFORMERAC 220V / 24V, 50 VA
G0 (NEUTRAL)
-1.0 ~ 9.0 bar
0.0 ~ 30.0 bar
G (HOT)
FUSE3A
100
200
250VAC 5AHIGH PRESSURE
Compressor #2 Alarm
Compressor #3 Alarm
Compressor #4 Alarm
Condenser #1 Alarm
Condenser #2 Alarm
Condenser #3 Alarm
Condenser #4 Alarm
Interlock Alarm
Remote Signal
MMI CONNECTIONRS-485 (MODBUS)
EXTENTION BOARD
G (HOT)
G (HOT)
pressure, discharge pressure)
MENU SELECT
RUN INFO
OPERATION
SCHEDULE
TRIP LOG
OPERATION
COMP SET VALUE : 1.8 barCOMP STEP DIFF : +0.40 barRUN/STOP DIFF : +1.00 barFAN SET VALUE : 13.0 barFAN STOP DIFF : + 0.7 bar
▶
TRIP LOG00 080102 15:55 POWER ON FIRST
01 080102 16:10 COMP#1 FAULT
02 080102 16:30 COMP#2 FAULT
03 080102 16:30 COMP#3 FAULT
04 080102 16:45 COMP#4 FAULT
TRIP LOG STATE
COMP#1 FAULT 080102 16:30
LP : -1.00bar HP : 0.0barID (10~1):N (12~1):
08 20
06
:
STAND BY
2.0 2.0PV
barSP
HPrs 12.3
LOC STP
C1
CA1 CA2 CA3 CA4 FA1 FA2 FA3 FA4 ILC RET
C2 C3 C4 N10 N11 N12F1 F2 F3 F4 N9
barCurrent
bar
Low Pressure
Digital Output State
Opera�on State
Digital Input State
Lock Signal
Set LowPressure
Currrent Time
High Pressure
Alarm Message
EquipmentState Code
X
- Multi Condensing Unit
- Multi Compressor Control
Multi Compressor Controller
DX Series
SENSETE°C
H®
CW
CH
EAT-ED
GE®
RA
INB
OW
SHIM
AD
ENP
R ELEC
TRO
NIC
SKIM
OSEKO
NIC
HU
BA
KA
ISEO
HK
UR
AC
OR
DEX
FRIED
ELECTR
ICD
OTEC
H
V-B9
Sensing Technology Corporation 457-B Boni Avenue New Zaniga Mandaluyong City Tel No. 532-0088 Fax No. 531-7387www.heatsenze.com [email protected]
![Page 12: DOTECH SENSING & CONTROL - · PDF fileDOTECH SENSING & CONTROL ... Relay output : 4point, Temp. sensor input : 2 point DPR-TH1 : NTC 5k, ±0.3°C at 25°C(-50~105°C) FX32R Showcase](https://reader031.vdocuments.mx/reader031/viewer/2022021421/5ab587cd7f8b9ab47e8cf76c/html5/thumbnails/12.jpg)
AC 220V50/60Hz
SURGEABSORBER
NOISEFILTER
T1
AC TRANSFORMERAC 220V / 24V, 30VA
G0 (NEUTRAL)
G (HOT)
FUSE3A
OCR
UIC DX230H Series Controller
TERMINALNO
TERMINAL NO
SOL1
T1 N1
FUSE3ACM1
CY1
X7
X9
X10
X11
X12
+-
+-+-
CD1
AC 110V, 50/60Hzafter Noise filter Output Terminal
DESC. DESC.
N1 J21 - 1
J21 - 2
J21 - 3
J21 - 4
J21 - 5
J22 - 1
J22 - 2
J22 - 3
J22 - 4
J22 - 5
J23 - 1
J23 - 2
J23 - 3
J23 - 4
J23 - 5
N2
N3
N4
C1
N5
N6
N3
N8
C2
N9
N10
N11
N12
C3
J6 - 1
※ Shield Wire UseConnection Frame and BuildingGround
J6 - 2
J6 - 3J6 - 4J6 - 5
J6 - 6
Y1YG1
Y2YG2
Y3YG3
J1 - 1
J11 - 1 +VDCB4
Inlet Temp Sensor
Geo-Inlet Temp Sensor
Outlet Temp Sensor
Geo-outlet Temp Sensor
DC GAS TEMP
OVERLOADMAIN MOTOR
OIL PRESS ALARM
INT. THERMO ALARM
LOW PRESS SWITCH
HIGH PRESS SWITCH
B5
ID COMMON 1
GND
B1GND
GND
B2
B3
J11 - 2
J11 - 3J11 - 4
J12 - 1J12 - 2
J12 - 3J12 - 4J12 - 5
J13 - 5
J13 - 6
J13 - 4
J13 - 3
J13 - 2
J13 - 1 ID1
J14 - 1 ID6 Spare
COOL / HEAT-ONSWITCH
FLOW SWITCH
PUMP(FAN) ALARM
REMOTE ON/OFF
ID COMMON 2
SYSTEM BUS RS485
LOCAL BUS RS485
J14 - 2 ID7
J14 - 3 ID8
J14 - 4 ID9
J14 - 5 ID10
J14 - 6
TB1 - 1 SGB
A
SGB
A
TB1 - 2TB1 - 3
TB2 - 1TB2 - 2TB2 - 3
* Optional Spec.
* Optional Spec.
Inlet Temp reTrans.ANALOG#1(4~20mA)
Outlet Temp reTrans.ANALOG#2(4~20mA)
Geo-Outlet TempANALOG#2(4~20mA)
* Optional Spec.
IDC2
ID2
ID3
ID4
ID5
IDC1
J1 - 2
J1 - 3
FG
G0
G
LEGEND LEGEND
MAIN SOL #1ON/OFF CONTROL
COMP #1 MAIN/PW1ON/OFF CONTROL
COMP #1 STAR/PW2ON/OFF CONTROL
COMP #1 DELTAON/OFF CONTROL
L.INJECTIN SOLON/OFF SIGNAL
OUTPUT COMMON 2
OUTPUT COMMON 1
OUTPUT COMMON 3
NIGHT MODEON/OFF SIGNAL
COMPRESSORALARM SIGNAL
4 WAY SOLON/OFF CONTROL
BROWER (Pump)ON/OFF CONTROL
24VAC 50/60HzCONTROLLERPOWER INPUT
OPS
INT
LPS
HPS
COOL / HEAT SWITCH
Interlock Pump(Fan), Flow Switch
Overload Pump(Fan) Motor Alarm
Remote Run / Stop
MMI CONNECTIONRS-485 (MODBUS)
G (HOT)
EXTENTION BOARD
G (HOT)
N1
250VAC 5A
T
N
DX230H
DX230H which is an optimal control algorism designed for heat pump system has realized the best
control and stability with ideal control and perfect interface with safety devices. Its elegant graphic
LCD display and LED helps users to check the current state of the units. Also, it provides user with the
information about PM & trip alarm history for quick and easy treatment.
- Basic built-in control function for 1 cycle, 1~2 cycle
- Embedding the best control algorism for heat pump system
- Observation for input temperature of heat source & output temperature
(Generating alarm & trip against high & low temperature)
- Observation for input control temperature & output temperature
(Generating alarm & trip against high & low temperature)
- Observation & control for discharge gas temperature (Liquid injection function embedded)
- 4-way valve control and/or selected operation for cooling and heating
- Sequential and alternative operation in case of 2 cycle control
- Strong storing and/or monitoring function for trip alarm history/state (Max. 160 cases)
- Transmission output (Temperature transmission)
- PC monitoring system using RS485 communication based on MODBUS protocol
Applications- Geothermy & Water-cooled Heat Pump
- Air-cooled Heat Pump
- Waste Heat Recovery Pump
Screen Composition MENU Composition
MENU SELECT
RUN INFO
OPERATION
SCHEDULE
TRIP LOG
OPERATION
COOL SET VALUE : 7.0 ℃COOL SET VALUE NIGHT : 7.0 ℃COOL RUN DIFFERENTIAL : +1.0 ℃HEAT SET VALUE : 30.0 ℃HEAT RUN DIFFERENTIAL : -1.0 ℃
▶
TRIP LOG00 080102 15:55 POWER ON FIRST
01 080102 16:10 POWER ON
02 080102 16:30 COMP OCR
03 080102 16:30 POWER OFF
04 080102 16:45 COMP OCR
TRIP LOG STATE
COMP OCR 080102 16:30OPERATING(Y/D) GEO TEMP. : 24.8℃OUT : 15.0℃ HP : 12.1℃ID (10~1):N (12~1):
CurrentTemperature
Digital Output State
Opera�on Mode
Digital Input State
Lock Signal
Set Temperature
Current Time
Geothermy OutputTemperature
Alarm Message
EquipmentState Code
Equipment State(Failure, Alarm, Maintain)
Run/Stop State
Hea�ng,Cooling
State
Day/Night opera�on State
45
08
LOC
20
02
24.8
:
STAND BYGOOD
7.5PV SP
GEO TEMP. :
SOLCM CY CD LIS 4W PM
OCCOPSINT HPSLPS FSPILRET
STP HEAT DAY
HCS
ALR
C C
C
X
Wiring Diagram (DX230)
Geothermy Heat Pump Controller
DX Series
SEN
SETE
°CH
®C
WC
HEA
T-ED
GE®
RA
INB
OW
SHIM
AD
ENP
R E
LEC
TRO
NIC
SSE
KON
ICH
UB
A
KA
ISE
OH
KU
RA
CO
RD
EXFR
IED
ELE
CTR
ICK
IMO
DO
TEC
H
V-B10
Sensing Technology Corporation 457-B Boni Avenue New Zaniga Mandaluyong City Tel No. 532-0088 Fax No. 531-7387www.heatsenze.com [email protected]
![Page 13: DOTECH SENSING & CONTROL - · PDF fileDOTECH SENSING & CONTROL ... Relay output : 4point, Temp. sensor input : 2 point DPR-TH1 : NTC 5k, ±0.3°C at 25°C(-50~105°C) FX32R Showcase](https://reader031.vdocuments.mx/reader031/viewer/2022021421/5ab587cd7f8b9ab47e8cf76c/html5/thumbnails/13.jpg)
DX540H
UIC DX540H is a ideal controller for air source heat pump. It is based on microprocessor and
designed with algorithm optimised for air source heat pump. UIC DX540H operates efciently and
manages intensively refrigerant compressor of heat pump. It promotes energy-saving through judge
and control timing of capacity regulation. UIC DX540H is a system to prevent occurrence of
problem by alarming and inform of necessary maintenance.
- Adoption RISC MICOM with high reliability
- Large graphic LCD which can display in Korean, English and Chinese
- Easy to maintain and analyse troubles of equipment by storing 160 trip alarms log
- The best calculation function of defrosting timing by various combination of 8 sources
- Embedded day-timer to enable energy-saving operation
- Easy expansion due to various analog transmission output function
- Alarm function to inform of time to maintain and change expendables through
- Additional state output 4 relays for suction temperature, water temperature, automatic calculation
evaporation temperature, etc.
Applications- Air source heat pump
Screen Composition MENU Composition
Current Temperature(Inlet/Outlet)
Digital Output State
Operation State
Digital Input State
Lock Signal
Current Time
Temperature,OperationTime Info
Equipment State Code
Alarm Message
Heating/Cooling State
Discharge Fault
0820
02
:
24.5TSUC
TIN
TOUT
TAMB
50.0℃24.5℃26.0℃ 7.7℃
DEF 4W PM
OC1 LPS HPSOC2 FSL HCS RETID5
C1 C2 SOL
C
MENU SELECT
RUN INFO
OPERATION
SCHEDULE
TRIP LOG
OPERATION
▶
TRIP LOG00 080102 15:55 INLET FAULT
01 080102 16:10 OUTLET FAULT
02 080102 16:30 OUT AIR FAULT
03 080102 16:30 DISCHARGE FAULT
04 080102 16:45 EVAPO. FAULT
TRIP LOG STATE
LOC STPX
HEAT SET VALUE : 7.0°CHEAT SET VALUE : -50.0°CSTEP1 OP DEV. : -2.0°CSTEP2 OP DEV. : -3.0°CSTEP2 STOP DEV : 0.0°C
EVAPO.FAULT 0909102 16:30STATE : STAND BYTsuc. - 40.0 bar Tsp 0.0°CID (10~1) :N (12~1) :
Wiring Diagram (DX540H)
※ Recommended commnunication cables BELDEN 8761 or 9842
Air-Source Heat Pump Controller
DX Series
SENSETE°C
H®
CW
CH
EAT-ED
GE®
RA
INB
OW
SHIM
AD
ENP
R ELEC
TRO
NIC
SKIM
OSEKO
NIC
HU
BA
KA
ISEO
HK
UR
AC
OR
DEX
FRIED
ELECTR
ICD
OTEC
H
V-B11
Sensing Technology Corporation 457-B Boni Avenue New Zaniga Mandaluyong City Tel No. 532-0088 Fax No. 531-7387www.heatsenze.com [email protected]
![Page 14: DOTECH SENSING & CONTROL - · PDF fileDOTECH SENSING & CONTROL ... Relay output : 4point, Temp. sensor input : 2 point DPR-TH1 : NTC 5k, ±0.3°C at 25°C(-50~105°C) FX32R Showcase](https://reader031.vdocuments.mx/reader031/viewer/2022021421/5ab587cd7f8b9ab47e8cf76c/html5/thumbnails/14.jpg)
HTX20 Series Economical Module Type Temperature and HumiditySensor
HUMITRON® HTX20 series,OEM type product line, are modules for sensing temperature and humidity with reasonable price, high precision and high quality. They are ideal for various
application because of excellent stability. Their design reminds shuttle spacecraft. They are intended to minimize spatial constraints through compact-slip design when installed on HVAC or
control equipment. HUMITRON® HTX20 series are plug connection type. They can detect relative humidity, temperature and dew point by measuring.
Integration of temperature and humidity measurement function
Easy to be applied to the system
Compatibility plug-In design
Easy to install, Compact design, Slim size
3m cable for free
Features
Thermo-hygrostat, Humidier / Dehumidiers
Automation equipment / Equipment appliance / Medical appliances
Air supply and exhaust equipment
Equipment to collect temperature and humidity data
Applications
- Range : 0~100%RH / -10~60°C - Accuracy : ±3.0%RH / ±0.5°C
- Output : 4~20mA (2 wire) - Power input : 9~32Vdc / 12~24Vac
HTX20-FTS-502 : Humidity(1~3.6V), NTC5Kohm Passive
HTX20-FTS-103 : Humidity(1~3.6V), NTC10Kohm Passive
HTX20-FTS-1K : Humidity(1~3.6V), NTC1Kohm Passive
HTX20-FTS-PT100 : Humidity(1~3.6V), Pt100ohm Passive
HTX20-FTS-PT100 : Humidity(1~3.6V), Pt1000ohm Passive
“Direct Connection with a Thermal Element” means all of PT100, PT1000, NI1000, NTC5K and NTC10K are available.
Technical data & Model
HTX23 Series OEM Temperature and Humidity Sensor
HUMITRON® HTX23 series is a module for detection of temperature and humidity which is especially for OEM and satisfactory in aspects of price and quality. It provides users with 4~20mA
standard interface and it is designed with compact and slim shape, so users don’t need to consider any spatial restriction or exposure when it is installed inside or outside of various types of
climate control units or control facilities. Also, it can help users to reduce unnecessary cost and to minimize works efciency through to reduce unnecessary cost and to maximize works efciency
through combination of 4~20mA standard humidity output and various temperature outputs (including passive) according to users’ needs.
Unied function for measuring temperature & humidity.
Easy installation
Compact & slim size – 63(L) x 63(W) x 16(H) (mm)
Free 2m standard cable
Features
Constant temperature & humidity control
Temperature & humidity data collection
Humidier & dehumidier
Ventilation facility
Applications
- Range : 10~90%RH / -10~60°C - Accuracy : ±3.0%RH / ±0.5°C
- Output : 4~20mA (2 wire) - Power input : 12Vdc(6~30Vdc)
HTX23 – FHC : Humidity (4~20mA)
HTX23 – FBC : Temperature (4~20mA)
HTX23 – FPC – PT100 : Humidity (4~20mA), Direct connection with a thermal element (Passive)
HTX20 – FBS – PT100 : Direct connection with a thermal element (Passive)
HTX20 – FTS – 1K : Humidity (1~4V), Temperature (Direct connection with NTC1K (Passive)
“Direct Connection with a Thermal Element” means all of PT100, PT1000, NI1000, NTC5K and NTC10K are available.
Technical data & Model
HTX SeriesHTX
SEN
SETE
°CH
®C
WC
HEA
T-ED
GE®
RA
INB
OW
SHIM
AD
ENP
R E
LEC
TRO
NIC
SSE
KON
ICH
UB
A
KA
ISE
OH
KU
RA
CO
RD
EXFR
IED
ELE
CTR
ICK
IMO
DO
TEC
H
V-C12
Sensing Technology Corporation 457-B Boni Avenue New Zaniga Mandaluyong City Tel No. 532-0088 Fax No. 531-7387www.heatsenze.com [email protected]
![Page 15: DOTECH SENSING & CONTROL - · PDF fileDOTECH SENSING & CONTROL ... Relay output : 4point, Temp. sensor input : 2 point DPR-TH1 : NTC 5k, ±0.3°C at 25°C(-50~105°C) FX32R Showcase](https://reader031.vdocuments.mx/reader031/viewer/2022021421/5ab587cd7f8b9ab47e8cf76c/html5/thumbnails/15.jpg)
HTX3515 Analog Voltage RelativeHumidity Module (1.0~3.6V output)
HTX3515 is a dedicated humidity and play transducer designed for OEM applications where a reliable and accurate measurement is needed. Direct interface with a micro-controller is made
possible with the module’s humidity linear voltage. HTX3515 is designed for high volume and demanding applications.
Reliability not affected by repeated condensations
Demonstrated reliability and long term stability
Typical 1 to 3.6 Volt DC output for 0 to 100% RH at 5VDC supply
Humidity calibrated within +/-3%RH @ 55%RH
Operation Temperature : -40°C to 110°C
1.5mm Pitch Side Connector(JST)
Size : 27 x 12 x 7 mm
Product free from Lead, Cr(6+), Cd and Hg. Compliant with RoHS
Applications
1 : Black - humidity sensor power 0V
2 : Red - himidity power+5V
4 : White - Signal output for humidity measurement
Cable
HTX500 Series Ultra-precise Indoor Type Temperatureand Humidity Transmitter
HUMITRON® HTD500 series is an ultra-precise temperature & humidity transmitter for environmental measuring which integrates micro processor with a digital sensor based on MEMS
technology. It makes precise control and efcient observation possible by transmitting measured temperature and humidity information to analogue output , control and obser vation system
through RS485 communication function in real-time. Also, it supplies users excellent attention even at wide place by applying for a bog sized FND.
Wall-Unit
Digital sensor applied for MEMS technology
Embedded RS485 communication port based on MODBUS RTU/ASCII
Excellent long-term stability and self-digital correction
Quick counteraction speed (within 4 sec.)
Slim size – 310(L) x 280(H) x 45(D) (mm)
Features
Clean room / Measuring center / Inspection room
Food company / Pharmaceutical company R&D center, Process control
Computer room / Storage monitoring system
Storage for foods, medicines, cereals, woods and electronic devices
Applications
Range : 5~95%RH / -10~60°C
Accuracy – HTD520 : ±1.8%RH / ±0.3°C – HTD520 : ±3.0%RH / ±0.5°C
Output : 4~20mA, RS485 communication (MODBUS RTU/ASCII)
Power input : 24VDC (Free adaptor supplied)
HTD530 – 00 : Display only
HTX530 – 11 : Humidity (4~20mA), Temperature (4~20mA), RS485 communication
HTD520 – 00 : Display only
HTX520 – 11 : Humidity (4~20mA), Temperature (4~20mA), RS485 communication
Technical data & Model
Remote Probe-Unit
HTX Series
SENSETE°C
H®
CW
CH
EAT-ED
GE®
RA
INB
OW
SHIM
AD
ENP
R ELEC
TRO
NIC
SKIM
OSEKO
NIC
HU
BA
KA
ISEO
HK
UR
AC
OR
DEX
FRIED
ELECTR
ICD
OTEC
H
V-C13
Sensing Technology Corporation 457-B Boni Avenue New Zaniga Mandaluyong City Tel No. 532-0088 Fax No. 531-7387www.heatsenze.com [email protected]