dmc calibration klaus neumannproduct manager. page 2 dmc - camera head production raw die pan ccd...
TRANSCRIPT
DMC Calibration
Klaus Neumann Product Manager
Page 2
DMC - Camera Head ProductionDMC - Camera Head Production
Raw Die Pan CCD
Certification - Burn In & Test Flight
DMC Assembly
Lens assembly
Assemble Optics, Sensor & Electronics
Validation
Adjustment of CCD and Optics
Radiometric calibration
Geometric calibration
Calibrated Camera Heads
Delivery
Page 3
Zeiss Jena Clean Room FacilitiesZeiss Jena Clean Room Facilities
Page 4
Internal Calibration DataCalibration CD
homogeneous virtual image radiometry
mosaicking geometric quality assessment
Initial EO for all 8 camera heads
Adjusted, homogeneous pixel sensitivity
Color Balance
Interior Orientation
Data
PRC
PPS S/W Component
DMCORI
PPS S/W Component
DMC
Post Processing
Ulbricht SphereCollimator
RadiometryOnline PlatformGeometryRadiometryGeometry
PlatformSingle Head
DMC Calibration - OverviewDMC Calibration - Overview
Page 5
Geometric CalibrationGeometric Calibration
Designed for DMC
Rotationtable with 0.3 mgon accuracy
Circular Targets
Fully automatic
Zei
ss J
ena
Page 6
RadiometryRadiometry
Calibration with Ulbricht Sphere
Page 7
DMC DMC Environmental TestsEnvironmental Tests
RTCA / DO 160 E (= ISO 7137)
EN 61000-6-2:2001Electromagnetic compatibility (EMC) EN 61000-6-2:2001Electromagnetic compatibility (EMC)
Part 6-4: Generic standards Part 6-4: Generic standards
Section 2: Immunity for industrial environments Section 2: Immunity for industrial environments
Section 4: Emission standard for industrial environmentsSection 4: Emission standard for industrial environments
Part 4: Testing and measurement techniques Part 4: Testing and measurement techniques
Section 2: Electrostatic discharge immunity testSection 2: Electrostatic discharge immunity test
Section 5 : Surge immunity test Section 5 : Surge immunity test
EN55011:1998 Industrial, scientific and medical (ISM) radio-frequency equipment EN55011:1998 Industrial, scientific and medical (ISM) radio-frequency equipment
-Radio disturbance characteristics -Radio disturbance characteristics
-Limits and methods of measurement-Limits and methods of measurement
Page 8
DMC DMC Environmental TestsEnvironmental Tests
Vibration -Sinus: DO 160 E – Section 8 (Vibration) Figure 8-3 Category M (5 -500 Hz) (Standard Sinusidal Vibration Test curves for equipment installed in fixed wing aircraft with reciprocating or turbo propeller engines) -Random: ISO 9022-37 Category 21 (1,4 g rms @ 20-2000 Hz) Shock 15 g @ 11ms according ISO 9022-30 Category 01
Temperature -Temp-Burn In according own specification: Operating Temperature: 0 – 40°C T1 = 30min T2 = 4h T3 = 30min (In minimum 4 cycles) -Storage Temperature (according own specification):DMC Camera -20°C – 70°C (T1 = 1h T2 = 48h T3 = 1h)All other Equipment -40°C – 70°C (T1 = 1h T2 = 48h T3 = 1h)
Pressure -Under pressure RTCA / DO 160 E – Section 4 (Temperature & Altitude)Category C1 10700 m (guaranteed for customers only : 8000m)
T0 – T1: 30min T1–T2: 0 T2–T3: 4h Temperature 20°C
Page 9
Factory Acceptance and CertificationFactory Acceptance and Certification
– Factory acceptance Test
1st images taken and processed
Test procedure includes GPS simulated flight
– Test Flight
Full Mission -> Test field “Elchingen”
500m flying height
– 5cm GSD
8 control points
– AT is run to determine platform calibration
Page 10
Standard DIN 18740-4Standard DIN 18740-4Geometric Calibration ProtocolGeometric Calibration Protocol
Geometric Calibration Protocol for each camera module or spectral channel
Alignment of the IMU to the focal plane
For mosaicked images the relative orientation of the cameras for each exposure
Page 11
Noch Fragen ?Noch Fragen ?
Klaus Neumann
Z/I - Earth Imaging Solution Center
www.intergraph.com
Thank you !Thank you !