Safety at work on high voltage devicesDisconnecting and Earthing Devices provide easydisconnecting high voltage equipment from a high voltagebus bar and connect these parts to ground potential to

take away all electric energy, which might rest in capacitorsand other components. Our modular Disconnecting andEarthing Devices guarantee working safely ondisconnected and grounded high voltage installations.

Features Applications

Technical Data

� Switching coupled to the door:Forced and visible disconnecting of a high voltageinstallation from a supplying bus bar while opening thedoor or lid of the equipment.

� Protection again unintended connection:An open door of the Disconnecting and Earthing Devicemay be fixed by up to three padlocks.

� Modular technology - compact dimensions:A new technology of permanent magnetic treating ofthe light arc enables very compact dimensions. Thebasic contacts are integrated into one module, whichmay be delivered with additional earthing contacts toconnecting capacitors to ground potential.

� One part for mounting to the left and right side:The ZH 1500 has provisions for fastening it to the leftor right wall of a switch gear cabinet and reduces thenumber of spare parts.

A typical domain of our Disconnecting and Earthing Deviceis the power supply and power distribution of railwaycoaches. It is used in environments with single and multi-ple voltages. But also in switch gear cabinets and prozesscontrol, where high voltage is used, this device is the safetystandard.

Our ZH 1500 guarantees safety while working oninstallations, where high voltage requires diconnecting andearthing. These applications are to be found whereelectricity drives large machines or where high powerconsumption requires high voltage. Examples are railwaycoaches as well as industrial automation and powerplants. A ZH 1500 is mounted to the wall of a switch gearcabinet and the lever is mounted to the door. Openingthe door moves the blades and contacts and diconnectingand earthing is done.

Maximum loadDisconnecting-/ Earthing contact 250 kW / 250 kW

Number of disconnecting contacts 1Number of earthing contacts 1, optional +2 or +4

Number of auxiliary contacts Modul optional, 2x S800(see also data sheet D20)

Nominal voltage UnomFrequency f Unom f IthContinuous thermal current Ith

Disconnecting contact 1000 V AC 16 2/3 Hz 150 A1500 V AC 50 Hz 100 A1500 V DC --- 100 A3000 V DC --- 50 A

Earthing contact 3000 V DC --- 50 AAuxiliary contact 380 V AC 50 Hz 16 A

110 V DC --- 16 A

Blow-out method Arc chamber,Blow-out (permanent magnet)

Insulation, Testing voltage UTest 14 kVCycles, Mechanical life approx. 10000, min. 30 yearsApplication range Single- and Multivoltage vehiclesTemperature range -40 °C ...+85 °C

Mounting position horizontal, vertical(see mounting instructions)

Shock and vibration resitance 3 g 30 ms / 0,35g bei 20...150 HzProtection / Contamination degree IP 00 / PD 3Weight 11 kgDimensions (L x H x W) (145 x 415 x 470) mm

Discon. contact (ZS, WA) M8Termination Earthing contacts (PE) M6

Housing ( ) M6

Disconnecting and Earthing Device ZH 1500:Module without front plate. Visible is the lever (positionas door is open), that has to be mounted to the door.The position of the blades may be inspected from thefront, to be able to control correct function at all time.

Photo: Modul without front plate

Mounting Instructions, Circuit Diagram Standards

Device Outline

Example: ZH 1500 / 0

Series Additional earthing contacts

Disconnecting and 0 without additional earthing contactsZH 1500 2 two additional earthing contactsEarting Device 4 four additional earthing contacts

Note: � Special designs upon request� For some designs minimum order quantities may apply� Maintenance for ZH 1500 according to manual 1-0137-922751

Ordering Information

Mounting Instructions:� ZH 1500 may be fastend to the left or to the right wall.

Four borings on the left and another four borings on theright lateral surface of the casing are provided.

� Orientation of the ZH 1500 has to be orthogonal to thedriving direction.

� The optional delivered Auxialiary Contacts have to bemounted within the switching cabinet. Actuation is doneby the locking mechanism of the cabinet.

Circuit Diagram:

EN 50124: Railway applications - Insulations coordination.Part 1: Clearances and creepage distances for all

electrical and electronic equipment.EN 50153: Railway applications. Rolling stock. Protective

provisions relating to electrical hazards.EN 50155: Railway applications. Electronic equipment used

on rolling stock.VDE 0115: Railway applications - Rolling stock equipment -

Part 1: General construction and safety requirementsPart 2: Protective provisions relating to electrical hazards

Part 102: Supply voltages of traction systemsPart 106: Shock and vibrations testsPart 107: Basic requirements; clearances and creepage

distancesPart 200: Elektronic eqipment used on rolling stock

UIC 550-1: Electrical switch cabinets on passenger stocksUIC 550-2: Power supply systems for passenger coaches -

Type testingUIC 552: Electric power supply for trains - Standard