Directional Valve Size 10 WL 4.10 Installation dimensions ISO 4401/DIN 24340 A10

Upload: others

Post on 13-Jan-2022

57 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Directional Valve Size10 WL4 - KRACHT Corp

Directional Valve Size 10WL 4.10

Installation dimensions ISO 4401/DIN 24340 A10

Page 2: Directional Valve Size10 WL4 - KRACHT Corp

Directional Valve Size 10 Installation dimensions ISO 4401 / DIN 24340 A10

KRACHT GmbH · Gewerbestr. 20 · 58791 Werdohl, Germany · Phone +49(0)23 92 /935-0 · Fax +49(0)23 92 /935 209 · www.kracht-hydraulik.de · [email protected]

Nominal size 10

Maximum flow see p-Q characteristics

Max. operating pressureat ports P, A, B 5076 psi (350 bar)

Max. operating pressureat port T 3045 psi (210 bar)

Pressure losses see ∆p-Q characteristics

Hydraulic fluid Hydraulic oils of DIN 51524/25other Hydraulic fluids on request

Fluid temperature range(NBR) --22 ... +176 °F (--30 ... +80 °C)(FKM) -- 4 ... +176 °F (--20 ... +80 °C)

Ambient temperature max. ... +122 °F (... + 50 °C)

Viscosity range 98 ... 1840 SUS (20 ... 400 mm2/s)

Maximum degree of fluidcontamination Class 21/18/15 to ISO 4406.

Therefore we recommend a filterwith a retention rate β10 ≥ 75.

Permissible rated voltage variation AC: ± 10 %DC: ± 10 %

Max. switching frequency 15000 1/h

Switching time, on; at ν = 166 SUS (35 mm2/s) AC: 80 ... 330 ms

DC: 50 ... 120 ms

Switching time, off; at ν = 166 SUS (35 mm2/s) AC: 100 ... 280 ms

DC: 30 ... 90 ms

Duty cycle 100 %

Service life 107 cycles

Enclosure type to DIN 40 050 IP 65

Weight-valve with 1 Solenoid 3.9 kgvalve with 2 Solenoids 5.4 kg

Mounting position optional

Technical Data

The directional control valves WL 4 /10 consist of housing(1), control spool (5), centering springs (4) and operatingsolenoids (2, 3).The three-position directional valves are fitted with twosolenoids and two springs. The two-position directionalvalves have one solenoid and one return spring.The operating solenoids are DC solenoids and are suppliedthrough connectors A, B (6, 7) without rectifiers. For ACsupply the solenoids are provided with rectifiers, which areintegrated directly into the connectors A, B (6, 7). Theconnectors do not belong to delivery and must be ordered

Functional Description

separately. By loosening the fixing nut (8), the solenoid canbe turned on its axis and fixed in three positions 90° apart.Provided that the pressure in T-port does not exceed363 psi (25 bar), the spool of the valve can be repositionedby manual override (9).The basic surface treatment of the valve housing (1) isphosphate coated, whereas the operating solenoids (2, 3)are zinc coated.

Page 3: Directional Valve Size10 WL4 - KRACHT Corp

KRACHT GmbH · Gewerbestr. 20 · 58791 Werdohl, Germany · Phone +49(0)23 92 /935-0 · Fax +49(0)23 92 /935 209 · www.kracht-hydraulik.de · [email protected]

Directional Valve Vize 10 Installation dimensions ISO 4401 / DIN 24340 A10

3

Type Key

WL 4 F 10 P 2 E 6 Z 02400

Solenoid operated directional valves

Function

Nominal size

Ordering example

Installation dimensions ISO 4401

Internal special number

Solenoid

Spring return

Electric connection

Rated supplyvoltage of selenoids

E Coil for solenoid valve equipped with standard plug-in electrical connectoracc. to DIN 43 650

EG Coil for solenoid valve withintegrated rectifier equippedwith standard plug-in electricalconnector acc. to DIN 43 650

Y without electrical plug

Z with electrical plug (PG 11)

L with electrical plug and signal lightsin conduit adapter (PG 11)

01200 12V DC / 3.17 A

02400 24 V DC / 1.73 A

12060 120V AC / 0.35 A / 50 (60) Hz

23050 230V AC / 0.20 A / 50 (60) Hz

aother voltages on request

see page 4

see page 4

DIN 43 650, Protection IP 65, (DIN 40 050)

Note

Seal NBR (without marking)

OPTION FKM = V

Ordering example V – WL4 F 10 P 2 E 6 Z 02400

Directional valves with damping on request:T2 = nozzle Ø 0.6T3 = throttle screw

Directional valves with manual override on request:N2 = covered with rubber protective.

Page 4: Directional Valve Size10 WL4 - KRACHT Corp

Directional Valve Size 10 Installation dimensions ISO 4401 / DIN 24340 A10

KRACHT GmbH · Gewerbestr. 20 · 58791 Werdohl, Germany · Phone +49(0)23 92 /935-0 · Fax +49(0)23 92 /935 209 · www.kracht-hydraulik.de · [email protected]

Symbols

F ...31

Symbol SymbolSymbol

Sprin

g re

turn

Func

tion

Sprin

g re

turn

Func

tion

Sprin

g re

turn

Func

tion

EN...1 **

HE...1

AF...1

F ...4

SE...1

EN...0**

F ...0

F ...8

SE...0

BN...1 **

BP...1 *

F ...1AP...0*

AN...0**

U ...0

KF...0

SF...0

EN...6 **

P T

BA

a

** N =̂ Overlap (negative) * P =̂ Overlap (positive)

HE...6

FV...6

HF...6

AE...6

SF...6

KF...6

SE...6

F ...6

bTP

BA

BA

TP

BA

bTP

BA

BA

bTP

b

bTP

TP

BA

ba

BA

TPa

P T

BA

a

BA

a bTP

P T

BA

ba

TP

BA

a

A B

TPba

TP

BA

b

bTP

BA

P T

BA

a

P T

BA

ba

BA

TPa

P T

BA

ba

P T

BA

a

TP

BA

b

BA

P T

BA

ba

TP

BA

ba

P T

BA

a

P T

BA

aP T

ba

TP

BA

ba

AF...6TP

BA

ba AF...0

BA

TPa

AE...0

BA

TPa

HF...0

BA

TPa

AE...1

BA

bTP

HF...1 bTP

BA

SF...1

BA

bTP

Page 5: Directional Valve Size10 WL4 - KRACHT Corp

KRACHT GmbH · Gewerbestr. 20 · 58791 Werdohl, Germany · Phone +49(0)23 92 /935-0 · Fax +49(0)23 92 /935 209 · www.kracht-hydraulik.de · [email protected]

Directional Valve Size 10 Installation dimensions ISO 4401 / DIN 24340 A10

5

p-Q Characteristics Measured at ν = 166 SUS (32 mm2/s-1) and t = 104 °F (40 °C)

Operating limits for maximum hydraulic power transferred by the directional valveFor respective spool type – see Functional Symbols

Pres

sure

loss

∆p

in p

si (b

ar)

0

Flow Q in gpm (l/min)

5 10 15 20 25 30 37

500

1000

1500

2500

3500

4500

5000

13

102

1

3

5

4

(50)

(100)

(150)

(200)

(250)

(300)

(350)

4000

2000

3000

5072

(20) (40) (60) (80) (100) (120) (140)

35 0

12

8

9

7

6

11

(50)

(100)

(150)

(200)

(250)

(300)

(350)

500

1000

1500

2500

3500

4500

5000

4000

2000

3000

5072

5 10 15 20 25 30 3735

Flow Q in gpm (l/min)

(20) (40) (60) (80) (100) (120) (140)

∆p-Q Characteristics Measured at ν = 166 SUS (32 mm2/s-1) and t = 104 °F (40 °C)

Pres

sure

loss

∆p

in p

si (b

ar)

0

Flow Q in gpm (l/min)

5 10 15 20 25 32

100

150

200

2906

250

50

5

4

3

2

1

(20) (40) (60) (80) (100) (120)

(2)

(6)

8()

(12)

(14)

(16)

(20)

(18)

(10)

(4)

30

Pressure loss ∆p related to flow rate

P–A P–B A–T B–T P–T

F …6 1 1 2 2 –

F …0 – 1 2 – –

SE …6 1 1 2 2 1

SE …0 – 1 2 – 1

KF …6 1 1 2 2 –

KF …0 – 1 2 – –

SF …6 1 1 2 2 –

SF …0 – 1 2 – –

EN …6 4 3 4 5 1

EN …0 4 – – 5 1

AP …0 1 1 2 2 –

BP …1 1 1 2 2 –

HF …6 1 1 2 2 –

HF …0 – 1 2 – –

AE …6 1 1 1 2 2

AN …0 1 1 1 3 –

F …31 1 1 2 3 –

U …0 1 1 – – –

F …6 1F …0 1SE …6 1SE …0 1KF …6 1KF …0 1SF …6 5SF …0 5EN …6 3EN …0 3AP …0 2BP …1 2HF …6 4HF …0 4AE …6 7AN …0 2F …31 6U …0 8

Page 6: Directional Valve Size10 WL4 - KRACHT Corp

Directional Valve Size 10 Installation dimensions ISO 4401 / DIN 24340 A10

KRACHT GmbH · Gewerbestr. 20 · 58791 Werdohl, Germany · Phone +49(0)23 92 /935-0 · Fax +49(0)23 92 /935 209 · www.kracht-hydraulik.de · [email protected]

Dimensions (Dimensions in inches and milimetres in brackets)

Valve with two solenoids

1 Solenoid a2 Solenoid b3 Manual override4 Name plate5 Square Ring 12.42 x 1.68 mm

(5 pcs) supplied in delivery packet6 4 mounting holes7 Fixing nut of the solenoid8 Connector plug to DIN 43 6509 Distance reguired to remove plug

10 Throttle screw

Valve with one solenoid - a

Required surface finish to interface.

Page 7: Directional Valve Size10 WL4 - KRACHT Corp

KRACHT GmbH · Gewerbestr. 20 · 58791 Werdohl, Germany · Phone +49(0)23 92 /935-0 · Fax +49(0)23 92 /935 209 · www.kracht-hydraulik.de · [email protected]

Single-subplates for WL 4/10 Installation dimensions DIN 24340 A10

7

Type Key

BT

Ø11

A

P

90

4624

.4

5415.5 11

102

79.4

115

92

3

3320

A

TB

P

31

61.536.5

11.5 11.5

7243

1411

.5

Ø11

A

P

BT 120

46

16.2

23.9

12079.454

==

3645

92

Ø11

32243

Ø18

P

A

TB

75.5

11.5

14

20.3

64.236.28.2

41

43.5

Ports G 3⁄4

Installation dimensions A10 DIN 24 340

Ports G 1⁄2Installation dimensions A10 DIN 24 340

Ordering code: MWL 4 12 R4A •

Ordering code: MWL 4 12 R4A •

0 All 4 ports open1 Port A closed2 Port B closed3 Port P closed4 Ports A+B closed5 Ports B+P closed6 Ports A+P closed7 Ports A+T closed8 Ports B+T closed9 Port T closed

Nominal size Construction code

MWL 4 • R • A •

Ports G 1/2

Ports G 3/4

1012

34

Code no.

Page 8: Directional Valve Size10 WL4 - KRACHT Corp

KRACHT GmbH · Gewerbestr. 20 · 58791 Werdohl, Germany · Phone +49(0)23 92 /935-0 · Fax +49(0)23 92 /935 209 · www.kracht-hydraulik.de · [email protected]

With our decades of experience, we are at yourside, world-wide, for the professional mastery of specific applications andcomplete solutions inhydraulics and process technology.

WL4.10 / e / 10.06

Transfer Pumps

Transfer pumps for lubrica-ting oil supply equipment,low pressure filling and feedsystems, dosing and mixingsystems.

Industrial Hydraulics

Cetop directional controland proportional valves,hydraulic cylinders, pressure,quantity and stop valves forpipe and slab construction,hydraulic accessories forindustrial hydraulics (mobile and stationary use).

Flow Measurement

Gear and turbine flow metersand electronics for volume und flow meteringtechnology in hydraulics, processing and laqueringtechnology.

Mobile Hydraulics

Single and multistage high pressure gear pumps, hydraulic motors and valvesfor construction machinery, vehicle-mounted machines.

Overview ofour CompleteProgram